OZCO Project #287 - Pergola 8x10 with 4x4 Posts
Menards Overview
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
3048 120.00
=
2438 96.00
=
=
2316 91.19
2564 100.94
=
2456 96.69
1969 77.50
2648 104.25
OZCO Project #287 - Pergola 8x10 with 4x4 Posts Menards Overview
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
QTY. 4 2 2 1 2
PART NUMBER 51707 51775 51768 56627 51717
5 2 9 1 23
4x4x8L 2x6x10L 2x4x8L 4x4x10L 1x2x10L
DESCRIPTION 4x4 Post Base (4x4-PB-IW) 4” Post to Beam (P2B-IW-4) 4” Flush Inside 45 (FI45-IW-4) OWT Timber Screw 3-3/4" 2" Standard Rafter Clip (RC-IW-2) 4x4x8 2x6x10 2x4x8 4x4x10 1x2x10
Material List OZCO Project #287 Material List
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/13/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/13/2018 . Please visit OZCOBP.com to get current information.
1
51717
51768
51707
51775 56627
OZCO Menards Overview
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
Laredo Sunset & Ironwood 2 great styles Same functionality choose your connection lifestyle both styles available for most products Laredo Sunset (566XX series)
Laredo Sunset & Ironwood
Ironwood (517XX series)
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
1
Suggested Tools (others may be required) Menards Overview
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
45째
45째
4x4 Support (all lengths)
2x6 Beam (all lengths)
2x4 Purlin (all lengths)
51 2.00 X 45째
25 1.00 X 45째
Cutlist Menards Pergola Cutlist
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
3299 129.90
Locate desired center of structure
1969 77.50
if site is not level, see Ozco Site Leveling instruction
2648 104.25
8x10 site Menards Site Plan
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
= = flush
(HCN) Tool Required 3/8" Driver
Building your Canopy Menards Pergola Beams
(OWT Timber Screw)
use this procedure for all size Pergola's (8x8 shown). same construction steps and techniques apply. repeat on all sides.
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
1 2 4 3
ITEM QTY. PART DESCRIPTION NO. NUMBER 2x6 1 2 2x6x120.00 Board 4x4 2 4 Support 4x4x24.00 4� Flush 3 1 51768 Inside 45 (FI45-IW-4) OWT Timber 4 0.32 56627 Screw 33/4"
OZCO Project #287 - Pergola 8x10 with 4x4 Posts Menards Pergola Beams
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
CL
install this rafter on beam centerline ( CL ); see your configuration for quantity and spacing for subsequent rafters
beam
install on both ends of all rafters
flush
(HCN)
use this procedure for all size Pergola's (8x8 shown). same construction steps and techniques apply. repeat on all sides.
Tool Required 3/8" Driver
(OWT Timber Screw)
Installing your Rafters & Supports Menards Pergola Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
CL
= =
344 13.5 typ
4 ITEM NO. 1 2
QTY. 9 4
3
1
4
0.32
5
1
6
1.8
PART NUMBER 2x4 Board 4x4 Support 51768 56627 Menards Pergola Beams 51717
2 DESCRIPTION 2x4x96.0 4x4x29.5 4� Flush Inside 45 (FI45-IW-4) OWT Timber Screw 3-3/4"
6 3 1
12x12 Beams 2" Standard Rafter Clip (RC-IW-2)
OZCO Project #287 - Pergola 8x10 with 4x4 Posts Menards Pergola Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
install with nails or screws
CL 102 4.0 typ
use this procedure for all size Pergola's (8x8 shown). same construction steps and techniques apply. repeat on all sides.
beam
install first purlin on beam centerline ( CL ); see your configuration for quantity of purlins
Purlins Menards Pergola Purlins
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.
1
ITEM QTY. PART DESCRIPTION NO. NUMBER 1x2 1 23 Board 1x2x120.0
OZCO Project #287 - Pergola 8x10 with 4x4 Posts Menards Pergola Purlins
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/30/2016 . This information is updated periodically and should not be relied upon after 2 years from 3/30/2016 . Please visit OZCOBP.com to get current information.