OZCO Project #337 - Pavilion With Railing

Page 1

OZCO Project #337 - Railed in Pavilion

OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

1



16'0"

=

=

15 13'9 16 "

13 7'4 16 "

9 4'2 16 "

Overview-Front OZCO Project #337 - Railed in Pavilion

3 15'2 8 " V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

3


= = 3 12'3 4 " 1'4" typ

3 2'1 16 "

Overview-Top OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

4


14'0"

1 5'9 4 "

Overview-Right OZCO Project #337 - Railed in Pavilion

1 11'6 8 " V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

5


24

23

6

5

27

28

4

17 3 16 7 25

12 10

9

15

22

19

21 19

1

13

20

29

14

26

18

11

8

Bill of Material OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

6


ITEM NO. 1 2 3

QTY. 10 18 2 6 .48 1 4 1 4 8 1.28 16 16 14 7 2 2 3 2 5 .8 10 8 2 2 8

PART NUMBER DESCRIPTION 56608 6x6 Post Base Kit (6X6-PB-LS) 56641 2x4 Top Rail Saddle (2x4-TR) 56612 "T" Tie Plate (TTP) 56611 Truss Accent (TA-LS) 56625 Screw, OWT 1-3/4" (45mm) Timber 4 56629 OWT Timber Screw 7-1/2" 5 56618 4" Standard Rafter Clips (RC-LS-4) 6 56627 OWT Timber Screw 3-3/4" 7 56616 Flush Inside 45 (FI-45) 56611 Truss Accent (TA-LS) 56625 Screw, OWT 1-3/4" (45mm) Timber 8 56650 OWT Timber Bolt 6-8" 56680 2" Timber Bolt Heavy Duty Washer (OWT-TBW-2) 9 56650 OWT Timber Bolt 6-8" 56680 2" Timber Bolt Heavy Duty Washer (OWT-TBW-2) 10 56636 Post to Beam Bolt Offset (P2B-BO-LS) 11 56636 Post to Beam Bolt Offset (P2B-BO-LS) 12 56637 Post to Beam Bolt Inline (P2B-BI-LS) 13 56619 Truss Base Fan 8:12 56611 Truss Accent (TA-LS) 56625 Screw, OWT 1-3/4" (45mm) Timber 14 6x6 Cedar Post 6x6x8'0" 15 6x6 Cedar Support 6x6x3'0" 16 2x8 Cedar Board 2x8x16'0" 17 2x8 Cedar Board 2x8x12'0" 2x4 Cedar Board for 18 2x4x5'0" Rail Saddle 2x4 Cedar Board for 19 8 2x4x5'3 3/8" Rail Saddle 20 79 2x2 Cedar Board 2x2x3'0" 21 4 2x6 Cedar Board 2x6x5'0" 22 6 2x6 Cedar Board 2x6x5'3 3/8" 23 4 2x6 Cedar Board 2x6x4'2 9/16" 24 1 2x6 Cedar Board 2x6x14'0" 25 18 2x6 Cedar Board 2x6x11'0" 2x4 Cedar Board for 26 2 2x4x3'8 3/4" Rail Saddle 27 1 2x6 Cedar Board 2x6x3'8 3/4" 28 13 2x2 Cedar Board 2x2x6'0" 29 1 2x2 Cedar Board 2x2x4'0" some parts are grouped/used with others during assembly. when duplicate part numbers show on bill of material table, add together for total quantity needed. quantities reflect packages of components required

Bill of Material

OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

7


QTY. 10 18 2 19 4 1 4 1 4 30 23 4 3 2

PART NUMBER 56608 56641 56612 56611 56625 56629 56618 56627 56616 56650 56680 56636 56637 56619

10 2 2 2 1 12 1 52 5 5 1 18

6x6x8L 6x6x12L 2x8x16L 2x8x12L 2x4x8L 2x4x6L 2x2x10L 2x2x6L 2x6x10L 2x6x6L 2x6x14L 2x6x12L

DESCRIPTION 6x6 Post Base Kit (6X6-PB-LS) 2x4 Top Rail Saddle (2x4-TR) "T" Tie Plate (TTP) Truss Accent (TA-LS) OWT Timber Screw 1-3/4" OWT Timber Screw 7-1/2" 4" Standard Rafter Clip (RC-LS-4) OWT Timber Screw 3-3/4" Flush Inside 45 (FI-45) OWT Timber Bolt 6-8" 2" Timber Bolt Heav y Duty Washer (OWT-TBW-2) Post to Beam Bolt Offset (P2B-BO-LS) Post to Beam Bolt Inline (P2B-BI-LS) Truss Base Fan 8:12 6x6x8 6x6x12 2x8x16 2x8x12 2x4x8 2x4x6 2x2x10 2x2x6 2x6x10 2x6x6 2x6x14 2x6x12

Material List OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

8


56616

56611

56612 56608

56618

56650

56619

56641

56680

56625

56636 56627

56637

56626

OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

9


Laredo Sunset & Ironwood 2 great styles Same functionality choose your connection lifestyle both styles available for most products Laredo Sunset (566XX series)

Laredo Sunset & Ironwood

Ironwood (517XX series)

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

10


Suggested Tools (others may be required) OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

11


Cap (finger tight) Tool Required 3/8" Driver

OWT Timber Screw

see Overview page for spacing

step 1 OZCO Project #337 - Railed in Pavilion

see Overview page for spacing V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

12


Cap (finger tight) Tool Required 3/8" Driver

OWT Timber Screw Cap (finger tight) Tool Required 3/8" Driver

(Timber Bolt)

see Overview page for spacing

step 2 OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

13


Cap (finger tight) Tool Required 3/8" Driver

OWT Timber Screw

see Overview page for spacing

Cap (finger tight) Tool Required 3/8" Driver

(Timber Bolt)

step 3 OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

14


Cap (finger tight) Tool Required 3/8" Driver

OWT Timber Screw

step 4

see Overview page for spacing

OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

15


repeat previous step on remaining rafters

see Overview page for spacing

step 5 OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

16


Tool Required Torx T25 driver Screw

see Overview page for spacing

step 6 OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

17


secure with nails or screws

step 7

see Overview page for spacing

OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

18


secure with nails or screws

see Overview page for spacing

step 8 OZCO Project #337 - Railed in Pavilion

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

19


56° 1/2 scale template for 2x6 beam cut print 2x

11'0" rafter 5 28" 34° 1 1 16 "

13 1 16 "

3 1'1 8 "

7 (1 8 ") 2x width

56°

web post

56° 1 4'1 8 " 5'1"

1 3'11 4 "

3 5'3 8 "

56° 3 14" 34°

Special Cuts OZCO Project #337 - Railed in Pavilion

15 5 16 "

king post V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/21/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/21/2018 . Please visit OZCOBP.com to get current information.

20


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.