OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
1
Suggested Tools (others may be required) OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
3
10'0"
16'0" CL
15 3 16 " X 45°
~5" spacing 3" X 45°
1'0" 1'0" 5 10'1 16 "
8'0" posts
3 10'9 16 "
3'0" supports
CL 3 74"
1'0"
1'0"
as desired
1 13'6 8 "
1 7'6 8 "
Overview OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
4
3
7
5
8 2 11 4
10 12 9
13
6
1
Bill of Material OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
5
ITEM NO. 1
QTY.
PART NUMBER
4
6x6 Cedar Post
6x6x8'0"
2
4
2x8 Cedar Board
2x8x10'0"
3
35
2x2 Cedar Board
2x2x10'0"
4
4
6x6 Cedar Support
6x6x3'0"
5
6
Arched Canopy
Arched Canopy 3 Seam
6
2x12 Cedar Board
2x12x5'0"
6
2x12 Cedar Board
2x12x4'0"
6 7 8 9
4 18 4 4
51708 51793 51735 51710
6x6 Post Base (6x6-PB-IW) Rafter Seam (RS-IW) 6" Post to Beam (P2B-IW-6) 8" Post to Beam (P2B-IW-8)
10
1
51717
2" Standard Rafter Clips (RC-IW-2)
11
1
51768
4" Flush Inside 45 (FI45-IW-4)
12
1
56627
Screw, OWT 3-3/4" (95mm) Timber with HCN
2
56621
1 1/2" Hex Cap Nut (HCN)
4
51786
6x6 Post Band (6X6-BND-IW)
13
DESCRIPTION
Bill of Material OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
6
QTY. 4 2 4 35 6
PART NUMBER 6x6x8L 6x6x6L 2x8x10L 2x2x10L 2x12x10L
4 18 4 4 1 1 1 2 4
51708 51793 51735 51710 51717 51768 56627 56621 51786
DESCRIPTION 6x6x8 6x6x6 2x8x10 2x2x10 2x12x10 6x6 Post Base (6x6-PB-IW) Rafter Seam (RS-IW) 6" Post to Beam (P2B-IW-6) 8" Post to Beam (P2B-IW-8) 2" Standard Rafter Clips (RC-IW-2) 4" Flush Inside 45 (FI45-IW-4) Screw, OWT 3-3/4" (95mm) Timber with HCN 1 1/2" Hex Cap Nut (HCN) 6x6 Post Band (6X6-BND-IW)
Material List OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/13/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/13/2018 . Please visit OZCOBP.com to get current information.
7
51717
51708
51710
56621
51735
56627
51793 51768 51786 OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
follow QR barcode with your smart phone or visit OZCOBP.com for product installation instructions V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
7
Tool Required 1/4" Driver
Screw
see "Arched Canopy 3 Seam Instruction" (16' configuration) for cutlist template
OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
8
1 15'5 2 " 1 7'6 8 "
1 15'5 2 "
1 13'6 8 "
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
step 1 OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
9
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
=
=
step 2 OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
10
flush
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw Tool Required 1/4" Driver
Screw
step 3 OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
11
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
= =
step 4 OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
12
CL
=
=
=
Tool Required 1/4" Driver
Screw
step 5 OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
13
secure with nails or screws
step 6 OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
14
install in desired location
step 7 OZCO Project #351 - 10x16 Pergola With Triple Seam Curved Rafters
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/5/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/5/2018 . Please visit OZCOBP.com to get current information.
15