1
12'0" 1 44"
12'0"
CL 3" X 45°
~8" spacing
1 44"
1 2 2 " X 45°
CL
1" X 45°
4" 3'0" support 1'0" 1'0"
1'4" spacing 1'0"
8'0" post
1'0"
1 9'4 16 " as desired as desired
1 9'8 4 "
1 9'8 4 "
Overview OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
3
Suggested Tools (others may be required) OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
4
ITEM PART NO. QTY. NUMBER 4
3
7
10
1
4
52107
2
1
51768
3
8
51717
9
4
4
51775
11
5
1
56627
2
56621
6
8
51783
7
9
8
4
9
9
51793 4x4 Cedar Post Arched Rafter 2x12 Cedar Board 2x4 Cedar Board 4x4 Cedar Support 2x6 Cedar Board
5
12
2
18
1
6
Bill of Material OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
8
10
18
11
4
12
4
DESCRIPTION Lite 4X4 Post Base (4X4-PBIWL) 4" Flush Inside 45 (FI45-IW-4) 2" Standard Rafter Clips (RC-IW-2) 4� Post to Beam (P2BIW-4) Screw, OWT 3-3/4" (95mm) Timber with HCN 1 1/2" Hex Cap Nut (HCN) 4x4 Post Band (4X4-BND-IW) Rafter Seam (RS-IW) 4x4x8'0" Arched Rafter Assembly 2x12x6'0" 2x4x12'0" 4x4x3'0" 2x6x12'0"
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
5
4 1 8 4 1 2 8 9
PART NUMBER 52107 51768 51717 51775 56627 56621 51783 51793
Lite 4X4 Post Base (4X4-PB-IWL) 4" Flush Inside 45 (FI45-IW-4) 2" Standard Rafter Clips (RC-IW-2) 4� Post to Beam (P2B-IW-4) Screw, OWT 3-3/4" (95mm) Timber with HCN 1 1/2" Hex Cap Nut (HCN) 4x4 Post Band (4X4-BND-IW) Rafter Seam (RS-IW)
4 2 18 18 4
4x4x8L 4x4x6L 2x12x6L 2x4x12L 2x6x12L
4x4x8 4x4x6 2x12x6 2x4x12 2x6x12
QTY.
DESCRIPTION
Material List OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/12/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/12/2018 . Please visit OZCOBP.com to get current information.
6
51768 56621 51717 51775
56627
51793 51783
52107 OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
follow QR barcode with your smart phone or visit OZCOBP.com for product installation instructions
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
6
Tool Required 1/4" Driver
Screw
see "Arched Canopy 1 Seam Instruction" (12' configuration) for cutlist template Rafter OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
7
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
3 13'8 8 " 1 9'8 4 "
3 13'8 8 "
1 9'8 4 "
9/16 socket bolt
step 1 OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
8
Cap (finger tight) Tool Required 3/8" Driver
= =
OWT Timber Screw
flush
step 2 OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
9
Cap (finger tight) Tool Required 1/4" Driver
Screw
Tool Required 3/8" Driver
OWT Timber Screw
flush
step 3 OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
10
Tool Required 1/4" Driver
see Overview page for spacing
Screw
step 4 OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
11
see Overview page for spacing
Tool Required 1/4" Driver
Screw
step 5 OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
12
install in desired location
bolt
3/8 socket
step 6 OZCO Project #750 - 12x12 Pergola With Single Seam Curved Rafters - IW-LT
V2.00 - Installation Instructions, Specifications and Project Plans are effective 2/8/2018 . This information is updated periodically and should not be relied upon after 2 years from 2/8/2018 . Please visit OZCOBP.com to get current information.
13