OZCO Project #760 - Modern Fully Covered Patio (20X16)

Page 1

OZCO Project #760 - Modern Fully Covered Patio

OZCO Project #760 - Modern Fully Covered Patio

1

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.



3 20'1 4 "

16'0"

2'0"

2'0"

5 11'1 8 "

13 10'4 16 "

9 13' 16 "

1 15' 8 "

1 15'8 8 "

9 14'4 16 " 11 15'7 16 "

Overview OZCO Project #760 - Modern Fully Covered Patio

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

3


ITEM QTY. NO.

1

9

8

2

5

PART NUMBER OZCO Project #760 Modern Fully Covered Patio

1

1

2

16

56613

3

16

56649

4

8

56607

5

2

56615

4

56611

1

56625

6 12

56615 56611

2

56625

3 6 6

7

1

56648

1

56621

8

5

56680

9

1

56629

2

56621

7

4

Bill of Material OZCO Project #760 - Modern Fully Covered Patio

DESCRIPTION

see cutlist

Butt Joint Flush (BJF) OWT Timber Bolt 4-6" 4x4 Post Base (4x4-PB-LS) Flush Inside 90 (FI-90) Truss Accent (TA-LS) Screw, OWT 13/4" (45mm) Timber Flush Inside 90 Truss Accent (TA-LS) Screw, OWT 13/4" (45mm) Timber Screw, OWT 12" (304mm) Timber with HCN 1 1/2" Hex Cap Nut (HCN) 2" Timber Bolt Heavy Duty Washer (OWTTBW-2) Screw, OWT 71/2" (190mm) Timber with HCN 1 1/2" Hex Cap Nut (HCN)

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

4


56611

56615

56613

56607

56647

56649 56621

56680

56625

56629

follow QR barcode with your smart phone or visit OZCOBP.com for product installation instructions OZCO Project #760 - Modern Fully Covered Patio

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

5


Laredo Sunset & Ironwood 2 great styles Same functionality choose your connection lifestyle both styles available for most products Laredo Sunset (566XX series)

Laredo Sunset & Ironwood

Ironwood (517XX series)

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

6


2

8

9 6 5

7

3

4

1

Cutlist OZCO Project #760 - Modern Fully Covered Patio

ITEM QTY. DESCRIPTION NO. 4x12 True 1 4 Cedar 4x12 True 2 2 Cedar 3 2 2x8 Cedar 4 2 2x8 Cedar 5 2 1x2 Cedar 6 34 1x6 7 4 1x2 Cedar 8 2 1x2 Cedar 9 3 2x8 Cedar

LENGTH 12' 16' 14' 1/4" 20' 14'2" 20' 2' 7/8" 15'4 1/4" 13'8 1/2"

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

7


Suggested Tools (others may be required)

OZCO Project #760 - Modern Fully Covered Patio

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

8


3 22'1 4 "

Locate desired center of structure

3 22'1 4 "

11 15'7 16 "

1 15'8 8 "

if site is not level, see Ozco Site Leveling instruction step 1 OZCO Project #760 - Modern Fully Covered Patio

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

9


interior plates & fasteners not used

Cap (finger tight) Tool Required 3/8" Driver

step 2 OZCO Project #760 - Modern Fully Covered Patio

OWT Timber Screw V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

10


Cap (finger tight) Tool Required 3/8" Driver

step 3 OZCO Project #760 - Modern Fully Covered Patio

(Timber Bolt) V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

11


Cap (finger tight) Tool Required 3/8" Driver

step 4 OZCO Project #760 - Modern Fully Covered Patio

OWT Timber Screw V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

12


secure with nails or screws

step 5 OZCO Project #760 - Modern Fully Covered Patio

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

13


secure with nails or screws

step 6 OZCO Project #760 - Modern Fully Covered Patio

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

14


secure with nails or screws

step 7 OZCO Project #760 - Modern Fully Covered Patio

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

15


Translucent OZCO Project #760 - Modern Fully Covered Patio

V2.00 - Installation Instructions, Specifications and Project Plans are effective 12/31/2018 . This information is updated periodically and should not be relied upon after 2 years from 12/31/2018 . Please visit OZCOBP.com to get current information.

16


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.