OZCO Project #895 - Two Tier Pergola 26x16
OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
1
1 26'8 2 " 12'0" beam 1 8'8 2 "
10'0" beam
CL
1'0" 1" X 45.00°
15 3 16 " X 45.00°
8" spacing 1'0"
8" spacing
10'0" posts 9 7' 16 "
9'0" posts
15 8'4 16 "
1 9'6 8 " 5 24'2 8 "
Menards Fixer Upper II OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
3
12'0" rafters
16'0" rafters 1'4" spacing
Menards Fixer Upper II OZCO Project #895 - Two Tier Pergola 26x16
13 6 16 " V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
4
9'4" 4" 15 3 16 " X 45° 1'0"
9 10' 16 "
1 1'2 8 "
1'0"
9 7' 16 "
5 8'4 16 "
9'4" 13'4"
Menards Fixer Upper II OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
5
11
13
7
10
3
8
9
2 12
4 5
6 1
Menards Fixer Upper II OZCO Project #895 - Two Tier Pergola 26x16
ITEM PART NO. QTY. NUMBER DESCRIPTION 6x6 Post 1 8 51708 Base (6x6PB-IW) 8" Post to 2 18 51710 Beam (P2B-IW-8) 6-8" Joist Hanger 3 3.984 51739 Flush (JHF68-IW) 8" Post to 4 7.8 51717 Beam (P2B-IW-8) 1 1/2" Hex 5 1.6 56621 Cap Nut (HCN) Screw, OWT 3-3/4" 0.04 56627 (95mm) Timber 6x6 6 4 Cedar 6x6x10'0" Post 2x8 7 4 Cedar 2x8x16'0" Board 2x8 8 34 Cedar 2x8x12'0" Board 2x8 2x8x8'8 9 12 Cedar 1/2" Board 2x4 10 13 Cedar 2x4x16'0" Board 6x6 11 2 Cedar 6x6x4'0" Post 6x6 12 4 Cedar 6x6x9'0" Post 2x8 13 8 Cedar 2x8x10'0" Board
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
6
QTY.
PART NUMBER
8
51708
18
51710
4
51739
8
51717
2
56621
1
56627
8 1
6x6x10L 6x6x8L
6x6x10 6x6x8
4 34 20
2x8x16L 2x8x12L 2x8x10L
2x8x16 2x8x12 2x8x10
13
2x4x16L
2x4x16
DESCRIPTION 6x6 Post Base (6x6-PB-IW) 8" Post to Beam (P2B-IW-8) 6-8" Joist Hanger Flush (JHF-68-IW) 2" Standard Rafter Clip (RCIW-2) 1.5" Hex Cap Nut (HCN) OWT Timber Screw 3-3/4"
Purchase List OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
7
51739
51708
51710
56621
OZCO Project #895 - Two Tier Pergola 26x16
56627
51717
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
8
Suggested Tools (others may be required) OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
26
1" X 45° cut from 6x6x10L board qty: 4 10'0" 1" X 45° both ends cut from 6x6x8L board qty: 1 4'0"
4'0"
1" X 45° cut from 6x6x10L board qty: 4 9'0" 16'0" cut from 2x8x16L board qty: 4 15 3 16 " X 45° both ends 12'0" cut from 2x8x12L board qty:34 15 3 16 " X 45.00° both ends
Cutlist OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
10
1 8'8 2 " cut from 2x8x10L board qty: 12
10'0" cut from 2x8x10L board qty: 8
16'0"
cut from 2x4x16L board qty: 13
Cutlist OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
11
Mount Base to surface (top view shown) see post base installation instructions for detailed mounting instructrions & fastener selection 5 24'2 8 "
9'4" 13'4"
step 1 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
12
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
step 2 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
13
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw 3 1'7 4 "
2x8 board width
step 3 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
14
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
= =
see overview page for spacing dimensions
step 4 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
15
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
see overview page for spacing dimensions
step 5 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
16
Tool Required 1/4" Driver
Screw
see overview page for spacing dimensions
step 6 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
17
Tool Required 1/4" Driver
Screw
overhang of rafters equal on both ends
see overview page for spacing dimensions
step 7 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
18
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
see overview page for spacing dimensions
step 8 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
19
1 2'8 8 " 2x8 width
see overview page for spacing dimensions
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
step 9 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
20
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
see overview page for spacing dimensions
step 10 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
21
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
step 11 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
22
Cap (finger tight) 1 2' 8 "
Tool Required 3/8" Driver
OWT Timber Screw see overview page for spacing dimensions
step 12 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
23
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
see overview page for spacing dimensions
step 13 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
24
Tool Required 1/4" Driver
Screw
see overview page for spacing dimensions
step 14 OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
25
repeat steps 8-14 on opposite side
Menards Fixer Upper II OZCO Project #895 - Two Tier Pergola 26x16
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/16/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/16/2017 . Please visit OZCOBP.com to get current information.
26