OZCO Project #333 - DIY Vineyard Pergola Overview (10x12)
for dimensional details, see Overview page DIY Vineyard Pergola Overview
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/3/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/3/2018 . Please visit OZCOBP.com to get current information.
3 10' 8 " CL
12'0" CL
2'0"
2'0" =
= 13 7'4 16 "
1 9'4 8 "
9 8'2 16 "
1 7'4 8 "
Project 333 (10x12) DIY Vineyard Pergola Overview
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/3/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/3/2018 . Please visit OZCOBP.com to get current information.
Suggested Tools (others may be required) DIY Vineyard Pergola Overview
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/3/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/3/2018 . Please visit OZCOBP.com to get current information.
Material List 333 DIY Vineyard Material List
QTY .
PART NUMBER
DESCRIPTION
4 4 1 3 2
56608 56610 56628 56640 56639
6x6 Post Base (6x6-PB-LS) 8" Post to Beam (P2B-LS-8) OWT Timber Screw 5-3/4" 6-8" Joist Hanger Tab (JHT-68-LS) 6-8" Joist Hanger Flush (JHF-68-LS)
4 2 2 1 2 4 17 12
6x6x8L 2x8x12L 2x8x8L 4x4x12L 2x8x10L 2x6x8L 2x4x10L 2x2x10L
6x6x8 2x8x12 2x8x8 4x4x12 2x8x10 2x6x8 2x4x10 2x2x10
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
2
56627
56608
56610
56621
56677 (Project 327 & 340 only)
56639
56640
follow QR barcode with your smart phone or visit OZCOBP.com for product installation instructions DIY Vineyard Pergola OZCO
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/3/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/3/2018 . Please visit OZCOBP.com to get current information.
2x8 Cedar Board (see Template for end cut)
2x2 Cedar Board 1 11 8 "
2x6 Cedar Board
2x8 Cedar Board (see Template for end cut)
8'0"
12'0"
7'10"
11'0"
7'10"
12'0"
7 10 16 " 2x8 Cedar Board 6x6 Cedar Post
2x4 Cedar Board 2x4 Cedar Board
Project 333 DIY Vineyard Pergola (10x12) Cutlist DIY Vineyard Pergola Cutlist
Support defined on separate sheet
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/3/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/3/2018 . Please visit OZCOBP.com to get current information.
11 16 "
7 78" 1 2x R3 4 "
11 16 "
1 62"
Template (scale: 1/2)
DIY Vineyard Pergola Cutlist
V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/3/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/3/2018 . Please visit OZCOBP.com to get current information.
5 11'10 8 "
Locate desired center of structure
1 7'4 8 "
1 9'4 8 "
if site is not level, see Ozco Site Leveling instruction Project 333 (10x12) DIY Vineyard Pergola Base
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/3/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/3/2018 . Please visit OZCOBP.com to get current information.
1
4 Tip: To ensure level posts, use Post Level (OZCO #50740; not included)
Project 333 (10x12) step 1 DIY Vineyard Pergola Base
for dimensional details, see Overview page ITEM NO. 1
QTY.
2
4
4
PART NUMBER 6x6 Cedar Post 56608
DESCRIPTION 6x6x8'0" 6x6 Post Base Kit (6X6-PB-LS)
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/3/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/3/2018 . Please visit OZCOBP.com to get current information.
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
Project 333 (10x12) step 2 DIY Vineyard Pergola Base
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/3/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/3/2018 . Please visit OZCOBP.com to get current information.
ITEM Project 333 NO. (10x12)/QTY. 1
4
3
2
1
2
2
2
3 = =
4
Project 333 (10x12) DIY Vineyard Pergola Beam & Support
PART NUMBER 2x8 Cedar Board 2x8 Cedar Board
2
56628
3
56621
8
2x6 Cedar Board
DESCRIPTION 2x8x12'0" 2x8x9'9 7/8" Screw, OWT 53/4" (145mm) Timber with HCN 1 1/2" Hex Cap Nut (HCN) 2x6x3'0"
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
flush
flush
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
Project 333 (10x12) step 3 DIY Vineyard Pergola Beam & Support
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
once posts are even & level, temporarily secure structure with 2x4 & clamps then install beams then remove 2x4 & clamps
=
flush
=
9'10" move posts until top and bottom dimensions are the same and posts are level. dimension shown is for reference
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw 9'10"
Tip: To ensure level posts, use Post Level (OZCO #50740; not included)
Project 333 (10x12) step 4 DIY Vineyard Pergola Beam & Support
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
Cap (finger tight) Tool Required 3/8" Driver
OWT Timber Screw
Project 333 (10x12) step 5 DIY Vineyard Pergola Beam & Support
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
1
3
2
4
CL
2'0" CL
1'0"
2'0"
Project 333 (10x12) DIY Vineyard Pergola Rafters
ITEM NO.
QTY.
1
18
2
4
3
3
4
2
PART NUMBER DESCRIPTION 2x8 2x8x11 Cedar 1/8" Board 2x6 2x6x7'9 Cedar 7/8" Board 6-8" Joist Hanger 56640 Tab (JHT68-LS) 6-8" Joist Hanger 56639 Flush (JHF68-LS)
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
flush
Tool Required 1/4" Driver
Screw
Project 333 (10x12) step 6 DIY Vineyard Pergola Rafters
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
flush
line up Faux rafers with inside rafters
Tool Required 1/4" Driver
Screw
Project 333 (10x12) step 7 DIY Vineyard Pergola Rafters
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
flush
Tool Required 1/4" Driver
Screw
Project 333 (10x12) step 8 DIY Vineyard Pergola Rafters
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
1
2
3
ITEM NO.
QTY.
1
5
2
12
3
12
PART NUMBER DESCRIPTION 2x4 Cedar 2x4x12'0" Board 2x4 Cedar 2x4x10 7/16" Board 2x2 Cedar 2x2x11'0" Board
CL
= =
Project 333 (10x12) Purlins DIY Vineyard Pergola Purlins
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
2x4 Purlins are centered on Rafters and secured with provided screws at each intersection (not shown) CL
CL
Project 333 (10x12) step 9 DIY Vineyard Pergola Purlins
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
2x4 Purlins are centered on Rafters and secured with provided screws at each intersection (not shown) CL
CL
Project 333 (10x12) step 10 DIY Vineyard Pergola Purlins
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.
4" spacing
middle 2x2 Purlin C 2x4 Purlin L Spacing
1. 2. 3.
Project 333 (10x12) step 11 DIY Vineyard Pergola Purlins
Locate Center Line (CL ) between "2x4 Purlin Spacing". Install "middle 2x2 Purlin" on CL as shown. Secured provided screws at each intersection (not shown). Install additional 2x2 Purlins spaced as shown.
for dimensional details, see Overview page V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/4/2018 . This information is updated periodically and should not be relied upon after 2 years from 4/4/2018 . Please visit OZCOBP.com to get current information.