PLC UPS

Page 1

Product Brochure

ABB Power Quality Solutions PCS100 UPS-I, 150 kVA to 2400 kVA UPS Industrial


Ideal where very deep sags or short term power outages are a problem

2 Product Brochure | PCS100 UPS-I Industrial


PCS100 UPS-I, 150 kVA to 2400 kVA Utility voltage sags, surges, and short outages are common and often cause electric and electronic equipment to self protect by switching off. When this occurs in a critical control operation it can cause the complete shutdown of a facility. The results of a shutdown maybe considerable - eg : product loss, damaged equipment, and lost production time. The PCS100 UPS-I is an ideal solution where very deep sags or short term power outages are a problem. Product overview The ABB PCS100 UPS-I is an off line UPS with short time rated energy storage system, coupled to an inverter to allow the downstream load to remain operational through short outages and very deep sags of up to 30 seconds duration.

User benefits - Provides protection against short outages and very deep sags - Protects against utility recloser events - Provides back-up during generator start-up following a utility supply failure - Allows process loads to ride through common power problems increasing yield, reducing product wastage and improving productivity Features - Very high efficiency (typically 99%) - Suited to industrial loads (motors, drives, transformers, tools) - Modular design providing high reliability and short repair times - Very high fault capacity compared with standard UPS solutions - Extensive range of voltages available - Small footprint design - Custom storage solutions available - Not just another data centre UPS but a product designed for the much more demanding requirements of industrial applications PCS100 Industrial UPS ( UPS-I )

The actual ride through time is dependent on the load and the capacity of the storage system, which can be batteries or ultra capacitors. The PCS100 UPS-I operates with an on-line like speed of performance due to the revolutionary fast utility disconnect. The modular inverter construction and fail safe electromechanical bypass (optional) provides exceptional reliability and system availability.

Single line diagram Power supply before PCS100 UPS-I

Power suppied by the PCS100 UPS-I

Power supply after PCS100 UPS-I

Customer supplied Fail-Safe Bypass (optional)

UPS-I

Utility supply Distribution transformer

Circuit breaker

Input

Utility disconnect

Protected load Output

Coupling transformer Inverter

Battery option Ultra cap storage

PCS100 UPS-I Industrial | Product Brochure 3


Technical specifications Environmental

Input Supply voltage

- 220V / 400V / 480V + 10%

Enclosure IP rating

- IP20

Supply frequency

- 50Hz or 60Hz

Standard colour

- RAL 7035

Power system type

- 3 phase TN

Pollution degree rating

- 2

Over voltage category

- III

Minimum operating temp

- 00C, 32oF

Fault capacity

- Model dependent

Maximum operating temp

- 400C, 104oF

Efficiency (208-220V)

- > 98%

Ultra capacitor & battery temp

- 15-250C, 59-77oF

Efficiency (400-480V)

- > 99%

Humidity

- <95% non-condensing

Output

2UCD301083-P_h

Energy storage - 150 kVA to 2400 kVA

DC nominal voltage

- 750Vdc

- - 0.5 to +0.9

Ride through time - ultracap

- 3 sec @ 0.8 PF ( typical )

Fault capacity

- 20 pu for 200 mil sec

Interface

Series protection

- Customer supplied

User interface

- Graphic display module touch panel

Overload capacity

- 150% for 1 min

Digital I/O

- 3 input, 4 outputs

Serial coms

- Ethernet & Modbus TCP (monitoring only)

Rating Displacement power factor Utility disconnect

- 30 sec @ 0.8 PF ( typical )

- battery

Standards

Inverter supply Transition disturbance

- ≤¼ cycle

IEC 62040-1 - General and safety requirements for UPS

Min output voltage

- 90% @ end of discharge

IEC 62040-2 - Electromagnetic compatibility (EMC)

Fault capacity

- 1.5pu

IEC 62040-3 - Method : specifying the performance and test requirements

Physical dimensions The PCS100 UPS-I consists of 4 sub-assemblies : 2. Utility disconnect 3. Inverter 4. Coupling transformer 5. Energy storage Quantity of Cabinets 220V (without storage)

1xA

1xA

1xB

1xA

1xA

1xB

1xA

1xB

600

1xB

1xD

750

1xB

1xD

1xC

1xA

1xB

1xA

1xC

1xD 1xD

Inverter

Inverter

450

Coupling transformer

1xB

1xB

Coupling transformer

1xB

1xB

Coupling transformer

1xB

300

Inverter

150

kVA

Battery

Storage option Ultra caps ( 3s)

Utility disconnect

400V (without Storage) Utility disconnect

Utility disconnect

480V (without Storage)

1xA

1xA

1xA

2xA

1xC

1xA

1xD

1xA

2xA

1xC

1xA

1xD

2xA

3xA

900

1xC

1xA

1xD

1xC

1xA

1xD

1xC

1xA

1xD

2xA

3xA

1200

1xC

2xA

1xD

1xC

2xA

1xD

1xC

2xA

1xD

2xA

4xA

1500

1xC

2xA

1xE

1xC

2xA

1xE

1xC

2xA

1xE

2xA

6xA

1800

1xC

2xA

1xE

1xC

2xA

1xE

3xA

6xA

2400

1xC

3xA

1xE

1xC

3xA

1xE

4xA

8xA

Cabinet dimensions

Contact us ABB Limited LV Power Converter products Discrete Automation and Motion www.abb.com/powerquality

E

804 1209

1609

2154

1209

1204

1609

1209 804

804 1209

2154

Front view

1209

1209

809

D

2154

804

C

2154

B

2154

Plan view

A

804

Type