WHOLE HOME SOLUTIONS DUCTED & MULTI ROOM AIR CONDITIONING 2019/2020
TM
Complete Air Efficiency PANASONIC TECHNOLOGY Inverter Technology
Energy Saving and Precise Temperature Control Panasonic’s INVERTER reduces power consumption by varying the speed of the compressor according to the temperature changes with the aim of minimising the temperature fluctuations so you can enjoy consistent cooling comfort.
The “BRAIN” of the Inverter The Micro Computer Determines the most suitable operation mode as time passes and automatically adjusts power output for maximum comfort.
PAM (Pulse Amplitude Modulation) Increases compressor voltage rapidly to provide powerful cooling to reach the set temperature fast at start up.
PWM (Pulse Width Modulated Wave) Stabilises the compressor rotation speed when maintaining the set temperature.
HIGHEST FREQUENCY
PWM
2019 Panasonic P-TECh
Inverter
Power (Voltage)
EQUENC Y MAX FR DASH TO
Compressor Frequency (Hz)
DASH & HIGH COMPRESSOR FREQUENCY
2014 Panasonic
PAM Non-Inverter
Time
Time (min.)
P-TECh – The Power Behind Fast Cooling
Quick Cooling and Constant Comfort
Compressor achieves maximum frequency in the shortest time from start up.
PAM increases the power output to accelerate compressor speed at start up for quick cooling and stabilises the set temperature without wasting energy, offering constant comfort.
*P-Tech is only applicable for models with iAUTO-X function.
NON-INVERTER The Panasonic INVERTER air conditioner varies the rotation speed of the compressor, providing a precise method of maintaining the set temperature. Thus, Panasonic INVERTER air conditioners give you exceptional energy saving performance while ensuring you stay comfortable at all times. INVERTER
A conventional non-INVERTER air conditioner can only operate at a constant speed which is too powerful to maintain the set temperature. Thus, it switches the compressor on and off repeatedly. This results in wider temperature fluctuations leading to wasteful consumption of energy. NON-INVERTER
Little temperature Room temperature fluctuations
Legend:
Output Power
2 10
Remark: Saves energy by varying the rotation speed of the compressor to maintain the set temperature.
Set temperature
ON Time
ON
OFF
Legend:
Output Power Temperature
Set temperature Output power
Output power
Temperature
Room Big temperature temperature fluctuations
ON
OFF
ON Time
Remark: Energy is wasted by switching the compresso ON and OFF to maintain the set temperature.
or n
Technology
Eco-friendly Technologies Make smarter, greener choices with energy saving technologies for sustainable living
Sustainable Refrigerant
*Available with ducted and multi systems only, not applicable to mini VRF systems.
An Environmentally-friendly Refrigerant The commonly used refrigerants in air conditioning system contribute greatly to greenhouse gas emissions and ozone depletion, consequently putting our environment at stake. At Panasonic, we are committed to healthier lifestyles and to reducing our environmental footprint. That's why our air conditioners have been increasingly adopting the more eco-friendly R32 refrigerant. R32 refrigerant represents innovation in every way. It is an excellent heat transfer medium which leads to greater energy efficiency and cost effectiveness. R32 refrigerant also has low global warming potential, hence it's friendlier to the environment.
COOLING CAPACITY
R32 has higher cooling capacity thereby increases heat transfer efficiency.
ENERGY COSTS
It consumes less energy, helping you to save on electricity costs.
FRIENDLY
R32 has zero impact on the ozone layer, therefore it’s environment friendly.
REFRIGERANT PROPERTIES OF R22, R32, AND R410A What is R32?
R-32
R410A
R-22
Single Component
2 Components
Single Component
Chemical Formula
CH2F2
CH2F2 / CHF2CF3
CHCLF2
CH2F2: Single composition
Boiling Point (°C)
-51.7
-51.5
-40.8
GWPR32 ≈ 1 GWPR410A
Ozone Depletion Potential (ODP)
0
0
0.055
Global Warming Potential (GWP)
675
2090
1810
Pressure
1.6 x
1.6 x
1x
Synthetic Oil (FW50S)
Synthetic Oil (FV50S)
Mineral Oil
Ozone Depletion Potential (ODP) = 0
None
None
None
Non toxic
A2L Mildly flammable
A1 Non-flammable
A1 Non-flammable
Composition
Refrigerant Oil Toxicity Flammability
3
Lifetime in atmosphere is shorter, 4 – 9 years
11
3
Panasonic Comfort Cloud Control air conditioning units from wherever and whenever with your smartphone, by using Panasonic Comfort Cloud and WLAN smart adaptor. This scalable solution is ideal for one system, one site or multiple locations. Coupling the adapter with the already feature rich systems, makes it an ideal solution for both residential and commercial applications.
Comfort Cloud
48 4
For Residential
For Light Commercial
Remotely manage and monitor air conditioning units from anywhere anytime.
Gain control of multiple zones and sites intuitively up to 200 indoor units.
Comfort Cloud
Panasonic Comfort Cloud features Multiple User
Control air conditioning units by voice command intuitively connecting to smart speaker.*¹
The Panasonic Comfort Cloud App allows multiuser access control. Restrict user access to specific units.
From 1 to 200 units
Energy Monitor
User can control up to 200 indoor units. 10 different sites, with up to 20 units / groups per site.
See the estimated power consumption and compare with other periods to see how energy bill can be reduced even more.*²
Easy Scheduling
Error Codes
Complex weekly scheduling made simple. Not only for one units, but across multiple sites and from a smartphone.
Error code notification through the App, provides early notification and allows for faster repair.
SUN
MON
TUE
WED
THU
FRI
SAT
Custom timer according to your working day and hour
Application Examples
?
killowatt (kWh)
Voice Control
JAN
FEB
MAR
APR
Month
Controls Multiple Units in Multiple Locations
Boutique Hotel Room A
Room B
Lounge
Room C
Cashier
Reception Room 1
Room 2 Rest Area
Karaoke Room A
Room B
Room C
SPA Room D
Room E
Learning institute Centralised control from reception.
Office
Karaoke
Room A
Room B
Room C
Room D
Room E
Restaurants Restaurants
Multiple location control for small business.
System configuration Network Adaptor CZ-TACG1
Connection Diagram
CZ-CAPWFC1
Wireless LAN CZ-TACG1: For products for small sized project. (Page 40-41) CZ-CAPWFC1: Available for all types of VRF and PAC indoor unit.
Indoor Unit
Router
Panasonic Cloud Server
In conformity with IEEE 802.11
WLAN Smart Adaptor specification CZ-TACG1
Input Voltage Power Consumption Size [H x W x D] Weight Interface Wireless LAN Standard Frequency range Encryption Operation range
CZ-CAPWFC1
DC 1.2V (Supplied from indoor unit) Maximum 0.66W Maximum 2.4W 66 x 36 x 12mm 120 x 70 x 25mm Approx. 85g 190g (including communications lines) Wireless LAN IEEE 802.11 b/g/n 2.4GHz band WPA2-PSK(TKIP/AES) 0-55°C, 20 - 80RH%
Comfort Cloud App
Compatible Device and Browsers 1. IOS 9.0 or above 2. Android 4.4 or above
*1 Time of release in Quarter Three 2019. CZ-TACG1 or CZ-CAPWFC1 Network Adaptor required per unit. Requires an Internet connection and the App downloaded from the App Store or GooglePlay Store on your smartphone or tablet with the latest Operating System available. To use Amazon Alexa to control your air conditioner, you will need an Amazon Echo device. To use Google Assistant to control your air conditioner, you will need an Google Assistant device. Google is a trademark of Google LLC. Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates. *² Function available depending on the model.
549
CONTROL SOLUTIONS
Available on Ducted and mini VRF options, not available on multi systems.
Easy-to-use, with multiple energy saving functions at your fingertips
DELUXE WIRED REMOTE CONTROLLER LARGE 3.5” FULL-DOT LCD WITH WHITE LED BACKLIGHT Characters and icons are clearly displayed for perfect visibility. With the white LED backlight, you can now change the temperature during the night without even turning on the light.
STYLISH, EASY-TO-USE TOUCH KEY DESIGN The elegant, flat design features large touch keys in a simple layout enabling easy, intuitive operation.
PAC/VRF SMART CONNECTIVITY THE NEW FORM FOR CONTROL SOLUTIONS In collaboration with Schneider Electric, the SE8000 SER8150maintains maintains high IAQ while saving you energy. Its sleekly designed touch panel display is easy to use.
PLUG & PLAY FOR HOME AUTOMATION Easily connect with integrated controllers to become part of your automated home network.
PUSHTM
www.pushcontrols.com
CLIPSAL® www.clipsal.com/athome For further information, please check PUSH™ and CLIPSAL® website.
6
Systems
Ducted System Advantages • Discrete and quiet • Up to 8 rooms off one outdoor (up to 16kW) • Range of different grill options • Deluxe controller option • Smart WiFi & Voice Control compatible
Considerations • Requires access space either in the ceiling or under the house • Single set temperature for all rooms
DUCTED OUTDOOR
DUCTED INDOOR
7
Multi System MINI CASSETTE HIGHWALL
Advantages • Multiple indoor types • Up to 5 rooms off one outdoor (up to 10kW)
MULTI OUTDOOR
• Individual control of each indoor unit • Adjustable room temperatures • Can be installed in most ceilings • Smaller pipes so less space required in ceiling or underfloor cavity for installation • Smart WiFi & Voice Control compatible
FLOOR CONSOLE
Considerations BULKHEAD DUCTED
SLIM DUCTED
8
• Deluxe controller not available
Systems
Mini VRF System HIGHWALL
FLOOR CONSOLE
Advantages • Multiple indoor types • Up to 13 rooms off one outdoor (up to 28kW) • Entire house off one outdoor • Individual control of each indoor unit • Long pipe lengths • Adjustable room temperatures
LARGE DUCTED INDOOR
MINI CASSETTE
• Suitable for larger homes • Deluxe controller option • Smaller pipes so less space required in ceiling or underfloor cavity for installation • Smart WiFi & Voice Control compatible
FULL SIZE CASSETTE
Considerations • Higher cost
VRF OUTDOOR
• Expert design required • Larger units require 3 phase power
SLIM DUCTED
9
Ducted System
All side discharge R32 outdoor units Panasonic’s new range of outdoor units feature intuitive technology and thoughtful engineering. The two innovative ranges of R32 units, both Deluxe and Compact, feature energy and space saving technologies, permitting installation in even the tightest and demanding conditions.
More Efficient, Less Space Whilst maintaining its strong power, new R32 outdoor units get smaller. This enables them to fit into tighter spaces. Thus you can install these units in a vast variety of areas.
All side discharge from 6.0kw to 22.4kW U-71PZH2R5
U-100PZH2R5 U-100PZH2R8*
U-125PZH2R5 U-125PZH2R8*
U-140PZH2R5 U-140PZH2R8*
R32 Deluxe U-160PZH2R5 U-160PZH2R8*
U-180PZH2R8*
U-200PZH2R8*
U-224PZH2R8*
* 3 phase
Industry-leading Small Body with All 1-fan Models U-60PZ2R5
U-71PZ2R5
U-100PZ2R5 U-100PZ2R8*
U-125PZ2R5 U-125PZ2R8*
R32 Compact
U-140PZ2R5 U-140PZ2R8*
* 3 phase
6 10
Ducted System Outdoor Unit Features
Next Generation Refrigerant: R32 R32, an innovative refrigerant in all ways imaginable: it is easy to install, and compared to most other refrigerants it has a much lower environmental impact and saves energy.
R32 Deluxe
R32 Compact
• Low Global Warming Potential (GWP): 75% less impact on global warming vs R410A • Energy Efficient: Higher energy efficiency than R410A • Easy Installation: This refrigerant is 100% pure which makes it easier to recycle and reuse.
Energy Saving Technology
R32 Deluxe
The use of energy saving design for the structure of fans, fan motors, compressors and heat exchangers results in high EER and COP value, which ranks as one of the top in the industry. Cooling (EER)
Heating (COP) PZH2
5.0
5.0
4.0
4.06
4.30
4.41 3.80
2.0
2.0
1.0
1.0
10.0 kW
12.5 kW
4.30
3.41 3.0
7.1 kW
PZH2
4.61
4.0
3.0
0
5.00
0
14.0 kW
7.1 kW
10.0 kW
12.5 kW
14.0 kW
* The graph shows 4-WAY Cassette R32 Deluxe models values.
Precise Temperature Control Constant Comfort Air Conditioning
R32 Deluxe
R32 Compact
Another advantage of Panasonic Premium Inverter technology includes its ability to ensure precise temperature control and offer a wider power output range to perform in even the most extreme conditions in Australia, ensuring constant comfort. Low Room Temp.
Mid Room Temp.
High Room Temp.
Panasonic Up to
12.5 kW
3.1 kW R32 Deluxe
Comfort
25%
Higher Power Constantly Comfort
Up to
3.0 kW
11.5 kW
R32 Compact
Brand X
5.0 kW
Over Cooling
0 kW
10.0 kW
5 kW
Graph shows each models’ 10.0 kW Inverter High Static Pressure Ducted systems performance range during cooling.
15%
Higher Power Constanltly
Under Cooling
10 kW
15 kW
7 11
Indoor Unit High Static Pressure
Ducted System High static and large airflow ducted for exceptional installation flexibility.
Self-diagnosing Function
Automatic Fan Operation
Mild dry
ECONAVI ready
Automatic Restart Function
Compact Body Size Hidden in the ceiling, ideal when interior decor is an important consideration such as in residences with many rooms and light commercial buildings.
1,100
1,100
700
700
430
290 mm (S-60PE1R5B) 360 mm (S-71PE1R5B,
S-100PE1R5B)
S-60PE1R5B S-71PE1R5B S-100PE1R5B
System Example An inspection port (450 mm x 450 mm or more) is required at the control-box side of the indoor unit body.
S-125PE1R5B S-140PE1R5B S-160PE1R5B
Rectangle duct
Inspection port (450 x 450 mm or more)
14 12
Canvas duct
Intake grille
High Static Pressure Ducted
ECONAVI ready S-60PE1R5B S-71PE1R5B S-100PE1R5B
CZ-CENSC1
CZ-RTC5B
CZ-RTC4
CZ-CAPWFC1 CZ-CAPWFA1
S-125PE1R5B S-140PE1R5B S-160PE1R5B
Cold Drafts Reduced During Heating Operation • Accurate temperature measurement by E1/E2 sensor to reduce cold drafts during heating operation.
Air intake sensor E2 sensor E1 sensor
15 13
Indoor Unit: High Static Pressure
Ducted
Specifications of R32 Deluxe Model 7.1kW
Capacity Model Name
S-71PE1R5B
S-100PE1R5B
S-100PE1R5B
Outdoor Unit
U-71PZH2R5
U-100PZH2R5
U-100PZH2R8
kW
7.1 (2.2 - 9.0) 8.0 (2.0 - 9.0)
10.0 (3.1 - 12.5) 11.2 (3.1 - 14.0)
10.0 (3.1 - 12.5) 11.2 (3.1 - 14.0)
BTU/h
24,200 (7,500 - 30,700) 27,300 (6,800 - 30,700)
34,100 (10,600 - 42,700) 38,200 (10,600 - 47,800)
34,100 (10,600 - 42,700) 38,200 (10,600 - 47,800)
W/W kW
3.38 : 3.83 2.10 : 2.09
3.64 : 3.65 2.75 : 3.07
3.64 : 3.65 2.75 : 3.07
Phase/Hz V A mm kg L/s Pa dB(A) dB(A) mm
1 Phase/ 50Hz 230V | 240V 1.24 : 1.24 | 1.25 : 1.25 360×1,100 (+100)×700 42 500 : 500 100 (Max.150) 45 / 44 / 43 : 45 / 44 / 43 62 / 61 / 60 : 62 / 61 / 60 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.72 : 1.72 | 1.74 : 1.74 360×1,100 (+100)×700 44 666 : 666 100 (Max.150) 48 / 46 / 44 : 48 / 46 / 44 70 / 68 / 66 : 70 / 68 / 66 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.72 : 1.72 | 1.74 : 1.74 360×1,100 (+100)×700 44 666 : 666 100 (Max.150) 48 / 46 / 44 : 48 / 46 / 44 70 / 68 / 66 : 70 / 68 / 66 3 VP-25
Phase/Hz V A mm kg L/s dB(A) dB(A) mm m m m g ˚C
1 Phase/ 50Hz 230V | 240V 8.45 : 8.20 | 8.00 : 7.90 996 × 940 × 340 68 1,017 : 1,000 48 (46) : 50 (48) 64 (62) : 66 (64) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 1,950 / 45 (g/m) -15 to 46 : -20 to 24
1 Phase/ 50Hz 230V | 240V 10.8 : 12.2 | 10.20 : 11.6 1,416 × 940 × 340 99 1,967 : 1,800 52 (50) : 52 (50) 68 (66) : 68 (66) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
3 Phase/ 50Hz 400V | 415V 3.60 : 4.10 | 3.45 : 3.95 1,416 × 940 × 340 99 1,967 : 1,800 52 (50) : 52 (50) 68 (66) : 68 (66) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
10.0kW
Cooling capacity : Heating capacity EER : COP Total power input Indoor Unit
Cooling : Heating
Power source Current Dimensions Net weight Air volume External static pressure Sound pressure level (H/M/L) Sound power level (H/M/L) Number of fan speeds Drain pipe size Outdoor Unit
10.0kW
Indoor Unit
Cooling : Heating H×W×D Cooling : Heating Cooling : Heating Cooling : Heating
Power source Current Cooling : Heating Dimensions H×W×D Net weight Air volume Cooling : Heating Sound pressure level (Silent mode) Cooling : Heating Sound power level (Silent mode) Cooling : Heating Piping connections Liquid / Gas Pipe length min. - max. Elevation difference (OU located lower, OU located higher) Maximum chargeless length Refrigerant at shipping / Additional gas amount Operation ranges Cooling : Heating
Specifications of R32 Compact Model 6.0kW
7.1kW
Indoor Unit
S-60PE1R5B
S-71PE1R5B
S-100PE1R5B
Outdoor Unit
U-60PZ2R5
U-71PZ2R5
U-100PZ2R5
kW
6.0 (2.0 - 7.1) 6.0 (1.8 - 7.6)
7.1 (2.0 - 8.0) 7.1 (1.8 - 8.6)
10.0 (3.0 - 11.5) 10.0 (3.0 - 14.0)
BTU/h
20,500 (6,800 - 24,200) 20,500 (6,100 - 25,900)
24,200 (6,800 - 27,300) 24,200 (6,100 - 29,300)
34,100 (10,200 - 39,200) 34,100 (10,200 - 47,800)
W/W kW
3.23 : 3.92 | 3.23 : 3.92 1.86 : 1.53
3.18 : 4.06 | 3.18 : 4.06 2.23 : 1.75
3.33 : 3.89 | 3.44 : 3.89 3.00 : 2.57
Phase/Hz V A mm kg L/s Pa dB(A) dB(A) mm
1 Phase/ 50Hz 230V | 240V 0.85 : 0.85 | 0.86 : 0.86 290×1,100 (+100)×700 35 366 : 366 70 (Max.100) 43 / 41 / 40 : 43 / 41 / 40 60 / 58 / 57 : 60 / 58 / 57 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.24 : 1.24 | 1.25 : 1.25 360×1,100 (+100)×700 42 500 : 500 100 (Max.150) 45 / 44 / 43 : 45 / 44 / 43 62 / 61 / 60 : 62 / 61 / 60 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.72 : 1.72 | 1.74 : 1.74 360×1,100(+100)×700 44 666 : 666 100 (Max.150) 48 / 46 / 44 : 48 / 46 / 44 70 / 68 / 66 : 70 / 68 / 66 3 VP-25
Phase/Hz V A mm kg L/s dB(A) dB(A) mm m m m g ˚C
1 Phase/ 50Hz 230V | 240V 8.05 : 6.45 | 7.70 : 6.15 695 x 875 x 320 44 750 : 750 46 (44) : 48 (46) 65 (63) : 66 (64) Ø9.52 / Ø15.88 3 - 40 15, 30 30 R32 1,450 / 35 (g/m) -10 to 43 : -15 to 24
1 Phase/ 50Hz 230V | 240V 9.35 : 7.15 | 8.90 : 6.75 695 x 875 x 320 44 867 : 750 49 (47) : 49 (47) 67 (65) : 67 (65) Ø9.52 / Ø15.88 3 - 40 15, 30 30 R32 1,450 / 35 (g/m) -10 to 43 : -15 to 24
1 Phase/ 50Hz 230V | 240V 11.5 : 9.95 | 11.0 : 9.50 996 x 980 x 370 90 1,285 : 1,169 52 (50) : 52 (50) 68 (66) : 67 (65) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,600 / 45 (g/m) -10 to 43 : -15 to 24
Capacity Model Name
Cooling capacity : Heating capacity EER : COP Total power input
Cooling : Heating
Indoor Unit Power source Current Dimensions Net weight Air volume External static pressure Sound pressure level (H/M/L) Sound power level (H/M/L) Number of fan speeds Drain pipe size
Cooling : Heating H×W×D Cooling : Heating Cooling : Heating Cooling : Heating
Outdoor Unit Power source Current Cooling : Heating Dimensions H×W×D Net weight Air volume Cooling : Heating Sound pressure level (Silent mode) Cooling : Heating Sound power level (Silent mode) Cooling : Heating Piping connections Liquid / Gas Pipe length min. - max. Elevation difference (OU located lower, OU located higher) Maximum chargeless length Refrigerant at shipping / Additional gas amount Operation ranges Cooling : Heating
Notes: The Rated Capacity, Power Input and Running Current are measured in accordance with AS/NZS 3823 • Cooling: Indoor temperature: 27°C DB/ 19°C WB, Outdoor temperature: 35°C DB/ 24°C WB • Heating: Indoor temperature: 20°C DB/ 15°C WB, Outdoor temperature: 7°C DB/ 6°C WB
16 14
High Static Pressure Ducted
12.5kW
14.0kW
16.0kW
S-125PE1R5B
S-125PE1R5B
S-140PE1R5B
S-140PE1R5B
S-160PE1R5B
S-160PE1R5B
U-125PZH2R5
U-125PZH2R8
U-140PZH2R5
U-140PZH2R8
U-160PZH2R5
U-160PZH2R8
12.5 (3.2 - 14.0) 14.0 (3.2 - 16.0)
12.5 (3.2 - 14.0) 14.0 (3.2 - 16.0)
14.0 (3.3 - 16.0) 16.0 (3.3 - 18.0)
14.0 (3.3 - 16.0) 16.0 (3.3 - 18.0)
16.0 (5.5 - 18.0) 18.0 (5.5 - 20.0)
16.0 (5.5 - 18.0) 18.0 (5.5 - 20.0)
42,700 (10,900 - 47,800) 47,800 (10,900 - 54,600)
42,700 (10,900 - 47,800) 47,800 (10,900 - 54,600)
47,800 (11,300 - 54,600) 54,600 (11,300 - 61,400)
47,800 (11,300 - 54,600) 54,600 (11,300 - 61,400)
54,600 (18,800 - 61,400) 61,400 (18,800 - 68,200)
54,600 (18,800 - 61,400) 61,400 (18,800 - 68,200)
3.42 : 3.71 3.65 : 3.77
3.42 : 3.71 3.65 : 3.77
3.18 : 3.64 4.40 : 4.40
3.18 : 3.64 4.40 : 4.40
3.26 : 3.50 4.91 : 5.15
3.26 : 3.56 4.91 : 5.05
1 Phase/ 50Hz 230V | 240V 1.82 : 1.82 | 1.84 : 1.84 430×1,100 (+100)×700 48 833 : 833 100 (Max.150) 49 / 47 / 45 : 49 / 47 / 45 71 / 69 / 67 : 71 / 69 / 67 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.82 : 1.82 | 1.84 : 1.84 430×1,100 (+100)×700 48 833 : 833 100 (Max.150) 49 / 47 / 45 : 49 / 47 / 45 71 / 69 / 67 : 71 / 69 / 67 3 VP-25
1 Phase/ 50Hz 230V | 240V 2.62 : 2.62 | 2.70 : 2.70 430×1,100 (+100)×700 53 1,000 : 1,000 100 (Max.150) 51 / 49 / 47 : 51 / 49 / 47 73 / 71 / 69 : 73 / 71 / 69 3 VP-25
1 Phase/ 50Hz 230V | 240V 2.62 : 2.62 | 2.70 : 2.70 430×1,100 (+100)×700 53 1,000 : 1,000 100 (Max.150) 51 / 49 / 47 : 51 / 49 / 47 73 / 71 / 69 : 73 / 71 / 69 3 VP-25
1 Phase/ 50Hz 230V | 240V 2.62 : 2.62 | 2.70 : 2.70 430×1,100(+100) ×700 53 1,000 : 1,000 100 (Max.150) 51 / 49 / 47 : 51 / 49 / 47 73 / 71 / 69 : 73 / 71 / 69 3 VP-25
1 Phase/ 50Hz 230V | 240V 2.62 : 2.62 | 2.70 : 2.70 430×1,100(+100) ×700 53 1,000 : 1,000 100 (Max.150) 51 / 49 / 47 : 51 / 49 / 47 73 / 71 / 69 : 73 / 71 / 69 3 VP-25
1 Phase/ 50Hz 230V | 240V 14.8 : 15.4 | 14.1 : 14.6 1,416 × 940 × 340 99 2,083 : 1,867 53 (51) : 53 (51) 69 (67) : 69 (67) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
3 Phase/ 50Hz 400V | 415V 5.00 : 5.15 | 4.75 : 4.95 1,416 × 940 × 340 99 2,083 : 1,867 53 (51) : 53 (51) 69 (67) : 69 (67) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
1 Phase/ 50Hz 230V | 240V 17.4 : 17.4 | 16.5 : 16.5 1,416 × 940 × 340 99 2,150 : 1,933 54 (52) : 54 (52) 70 (68) : 70 (68) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
3 Phase/ 50Hz 400V | 415V 5.85 : 5.85 | 5.55 : 5.55 1,416 × 940 × 340 99 2,150 : 1,933 54 (52) : 54 (52) 70 (68) : 70 (68) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
1 Phase/ 50Hz 230V | 240V 20.0 : 21.1 | 18.9 : 20.0 1,500 × 980 × 370 117 2,733 58 (56) : 60 (58) 76 (74) : 78 (76) Ø9.52 / Ø19.05 5 - 75 30, 30 30 R32 3,200 / 45 (g/m) -15 to 46 : -20 to 24
3 Phase/ 50Hz 400V | 415V 6.95 : 7.15 | 6.60 : 6.80 1,500 × 980 × 370 115 2,733 58 (56) : 60 (58) 76 (74) : 78 (76) Ø9.52 / Ø19.05 5 - 75 30, 30 30 R32 3,200 / 45 (g/m) -15 to 46 : -20 to 24
12.5kW
14.0kW
S-100PE1R5B
S-125PE1R5B
S-125PE1R5B
S-140PE1R5B
S-140PE1R5B
U-100PZ2R8
U-125PZ2R5
U-125PZ2R8
U-140PZ2R5
U-140PZ2R8
10.0 (3.0 - 11.5) 10.0 (3.0 - 14.0)
12.5 (3.2 - 13.5) 12.5 (3.3 - 15.0)
12.5 (3.2 - 13.5) 12.5 (3.3 - 15.0)
14.0 (3.3 - 15.0) 14.0 (3.4 - 16.0)
14.0 (3.3 - 15.0) 14.0 (3.4 - 16.0)
34,100 (10,200 - 39,200) 34,100 (10,200 - 47,800)
42,700 (10,900 - 46,100) 42,700 (11,300 - 51,200)
42,700 (10,900 - 46,100) 42,700 (11,300 - 51,200)
47,800 (11,300 - 51,200) 47,800 (11,600 - 54,600)
47,800 (11,300 - 51,200) 47,800 (11,600 - 54,600)
3.33 : 3.89 | 3.44 : 3.89 3.00 : 2.57
3.30 : 4.00 | 3.30 : 4.00 3.79 : 3.125
3.30 : 4.00 | 3.30 : 4.00 3.79 : 3.125
3.15 : 3.66 | 3.15 : 3.66 4.44 : 3.825
3.15 : 3.66 | 3.15 : 3.66 4.44 : 3.825
1 Phase/ 50Hz 230V | 240V 1.72 : 1.72 | 1.74 : 1.74 360×1,100(+100)×700 44 666 : 666 100 (Max.150) 48 / 46 / 44 : 48 / 46 / 44 70 / 68 / 66 : 70 / 68 / 66 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.82 : 1.82 | 1.84 : 1.84 430×1,100(+100)×700 48 833 : 833 100 (Max.150) 49 / 47 / 45 : 49 / 47 / 45 71 / 69 / 67 : 71 / 69 / 67 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.82 : 1.82 | 1.84 : 1.84 430×1,100(+100)×700 48 833 : 833 100 (Max.150) 49 / 47 / 45 : 49 / 47 / 45 71 / 69 / 67 : 71 / 69 / 67 3 VP-25
1 Phase/ 50Hz 230V | 240V 2.62 : 2.62 | 2.70 : 2.70 430×1,100(+100)×700 53 1,000 : 1,000 100 (Max.150) 51 / 49 / 47 : 51 / 49 / 47 73 / 71 / 69 : 73 / 71 / 69 3 VP-25
1 Phase/ 50Hz 230V | 240V 2.62 : 2.62 | 2.70 : 2.70 430×1,100(+100)×700 53 1,000 : 1,000 100 (Max.150) 51 / 49 / 47 : 51 / 49 / 47 73 / 71 / 69 : 73 / 71 / 69 3 VP-25
3 Phase/ 50Hz 400V | 415V 3.90 : 3.40 | 3.75 : 3.24 996 x 980 x 370 90 1,285 : 1,169 52 (50) : 52 (50) 68 (66) : 67 (65) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,600 / 45 (g/m) -10 to 43 : -15 to 24
1 Phase/ 50Hz 230V | 240V 15.6 : 12.6 | 14.9 : 12.0 996 x 980 x 370 94 1,436 : 1,302 55 (53) : 55 (53) 70 (68) : 70 (68) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,980 / 45 (g/m) -10 to 43 : -15 to 24
3 Phase/ 50Hz 400V | 415V 5.20 : 4.15 | 4.95 : 4.00 996 x 980 x 370 94 1,436 : 1,302 55 (53) : 55 (53) 70 (68) : 70 (68) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,980 / 45 (g/m) -10 to 43 : -15 to 24
1 Phase/ 50Hz 230V | 240V 18.2 : 15.0 | 17.2 : 14.1 996 x 980 x 370 94 1,486 : 1,386 56 (54) : 56 (54) 71 (69) : 71 (69) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,980 /45 (g/m) -10 to 43 : -15 to 24
3 Phase/ 50Hz 400V | 415V 6.05 : 4.95 | 5.75 : 4.70 996 x 980 x 370 94 1,486 : 1,386 56 (54) : 56 (54) 71 (69) : 71 (69) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,980 / 45 (g/m) -10 to 43 : -15 to 24
17 15
Indoor Unit High Static Pressure
Slim-line Ducted System Control all aspects of your environment with exceptional performance and quiet operation. A perfect solution when ceiling heights are restricted.
ECONAVI ready
DC motor Self-diagnosing Function
Automatic Fan Operation
Mild dry
Automatic Restart Function
Built-in Drain Pump
DC Motor
Technical focus • Space saving 290mm height • DC fan motor for variable external static pressure control • Easy to install and maintain
• Accurate temperature control to reduce cold drafts during operation • Configurable air temperature control
Variable external static pressure control Optimal airflow set-up is possible for different ducting design and conditions. Optimal Control by DC Motor For short ducting such as hotels
10Pa
150Pa
For long ducting or for usage with high density filter
* Please refer to technical documents for detail.
System example
Canvas duct
Rectangle duct
An inspection port (450 mm x 450 mm or larger) is required at the lower side of the indoor unit body. Intake grille
Inspection port (450 x 450 mm or more)
More powerful drain pump Using a high-lift built-in drain pump, drain piping can be elevated up to 701 mm from the base of the unit.
Up to 300 mm Up to 500 mm 201 mm
20 16
High Static Pressure Slim-line Ducted
ECONAVI ready S-60PF1E5B S-71PF1E5B
CZ-CENSC1
CZ-RTC5B
CZ-RTC4
CZ-CAPWFC1 CZ-CAPWFA1
S-100PF1E5B S-125PF1E5B S-140PF1E5B
Built-in Drain pump (DC motor pump)
External electrical equipment box makes maintenance easy
Space saving height of 290mm for all models 290mm standardised height provides easy and uniform installation for models with different capacities, especially when ceiling heights are restricted.
• Built-in filter • Side removable filter
Discharge air temperature control • Possible to control discharge air temperature for accurate room temperature control. • Possible to reduce cold drafts during heating operation.
Air intake sensor
* Before spec-in, please consult with an authorised Panasonic dealer.
E2 sensor E1 sensor
V-shaped heat exchanger To improve heat exchange efficiency, an original V-shaped heat exchanger was developed incorporating a conventional high-efficiency fan and high-efficiency grooved heat transfer tubes. This increases the heat exchange surface area. Increases surface area
21 17
Indoor Unit: High Static Pressure
Slim-line Ducted
Specifications of R32 Deluxe Model Capacity Model Name
7.1KW S-71PF1E5B
S-100PF1E5B
S-100PF1E5B
Outdoor Unit
U-71PZH2R5
U-100PZH2R5
U-100PZH2R8
kW
7.1 (2.2 - 9.0) 8.0 (2.0 - 9.0)
10.0 (3.1 - 12.5) 11.2 (3.1 - 14.0)
10.0 (3.1 - 12.5) 11.2 (3.1 - 14.0)
BTU/h
24,200 (7,500 - 30,700) 27,300 (6,800 - 30,700)
34,100 (10,600 - 42,700) 38,200 (10,600 - 47,800)
34,100 (10,600 - 42,700) 38,200 (10,600 - 47,800)
W/W kW
3.84 : 4.00 1.85 : 2.00
4.13 : 4.31 2.42 : 2.60
4.13 : 4.31 2.42 : 2.60
Phase/Hz V A mm kg L/s Pa dB(A) dB(A) mm
1 Phase/ 50Hz 230V | 240V 0.89 : 0.89 | 0.87 : 0.87 290×1,000×700 33 350 : 350 70 (10 - 150) 35 / 32 / 26 : 35 / 32 / 26 57 / 54 / 48 : 57 / 54 / 48 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.30 : 1.34 | 1.27 : 1.29 290×1,400×700 45 533 : 533 100 (10 - 150) 38 / 34 / 31 : 38 / 34 / 31 60 / 56 / 53 : 60 / 56 / 53 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.30 : 1.34 | 1.27 : 1.29 290×1,400×700 45 533 : 533 100 (10 - 150) 38 / 34 / 31 : 38 / 34 / 31 60 / 56 / 53 : 60 / 56 / 53 3 VP-25
Phase/Hz V A mm kg L/s dB(A) dB(A) mm m m m g ˚C
1 Phase/ 50Hz 230V | 240V 8.00 : 8.50 | 7.65 : 8.25 996 × 940 × 340 68 1,017 : 1,000 48 (46) : 50 (48) 64 (62) : 66 (64) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 1,950 / 45 (g/m) -15 to 46 : -20 to 24
1 Phase/ 50Hz 230V | 240V 10.2 : 11.0 | 9.75 : 10.5 1,416 × 940 × 340 99 1,967 : 1,800 52 (50) : 52 (50) 68 (66) : 68 (66) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
3 Phase/ 50Hz 400V | 415V 3.40 : 3.70 | 3.30 : 3.55 1,416 × 940 × 340 99 1,967 : 1,800 52 (50) : 52 (50) 68 (66) : 68 (66) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
10.0KW
Cooling capacity : Heating capacity EER : COP Total power input Indoor Unit
Cooling : Heating
Power source Current Dimensions Net weight Air volume External static pressure Sound pressure level (H/M/L) Sound power level (H/M/L) Number of fan speeds Drain piping Outdoor Unit
10.0KW
Indoor Unit
Cooling : Heating H×W×D Cooling : Heating Cooling : Heating Cooling : Heating
Power source Current Cooling : Heating Dimensions H×W×D Net weight Air volume Cooling : Heating Sound pressure level Cooling : Heating Sound power level Cooling : Heating Piping connections Liquid / Gas Pipe length min. - max. Elevation difference (OU located lower, OU located higher) Maximum chargeless length Refrigerant at shipping / Additional gas amount Operation ranges Cooling : Heating
Specifications of R32 Compact Model Capacity Model Name
6.0KW
7.1KW
Indoor Unit
S-60PF1E5B
S-71PF1E5B
S-100PF1E5B
Outdoor Unit
U-60PZ2R5
U-71PZ2R5
U-100PZ2R5
kW
6.0 (2.0 - 7.1) 6.0 (1.8 - 7.6)
7.1 (2.0 - 8.0) 7.1 (1.8 - 8.6)
10.0 (3.0 - 11.5) 10.0 (3.0 - 14.0)
BTU/h
20,500 (6,800 - 24,200) 20,500 (6,100 - 25,900)
24,200 (6,800 - 27,300) 24,200 (6,100 - 29,300)
34,100 (10,200 - 39,200) 34,100 (10,200 - 47,800)
W/W kW
3.80 : 4.51 | 3.80 : 4.51 1.58 : 1.33
3.41 : 4.15 | 3.41 : 4.15 2.08 : 1.71
3.66 : 4.31 2.73 : 2.32
Phase/Hz V A mm kg L/s Pa dB(A) dB(A) mm
1 Phase/ 50Hz 230V | 240V 0.89 : 0.89 | 0.87 : 0.87 290×1,000 ×700 33 350 : 350 70 (10 - 150) 35 / 32 / 26 : 35 / 32 / 26 57 / 54 / 48 : 57 / 54 / 48 3 VP-25
1 Phase/ 50Hz 230V | 240V 0.89 : 0.89 | 0.87 : 0.87 290×1,000 ×700 33 350 : 350 70 (10 - 150) 35 / 32 / 26 : 35 / 32 / 26 57 / 54 / 48 : 57 / 54 / 48 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.30 : 1.34 | 1.27 : 1.29 290×1,400 ×700 45 533 : 533 100 (10 - 150) 38 / 34 / 31 : 38 / 34 / 31 60 / 56 / 53 : 60 / 56 / 53 3 VP-25
Phase/Hz V A mm kg L/s dB(A) dB(A) mm m m m g ˚C
1 Phase/ 50Hz 230V | 240V 7.05 : 5.85 | 6.75 : 5.60 695 x 875 x 320 44 750 : 750 46 (44) : 48 (46) 65 (63) : 66 (64) Ø9.52 / Ø15.88 3 - 40 15, 30 30 R32 1,450 / 35 (g/m) -10 to 43 : -15 to 24
1 Phase/ 50Hz 230V | 240V 9.35 : 7.70 | 8.95 : 7.35 695 x 875 x 320 44 867 : 750 49 (47) : 49 (47) 67 (65) : 67 (65) Ø9.52 / Ø15.88 3 - 40 15, 30 30 R32 1,450 / 35 (g/m) -10 to 43 : -15 to 24
1 Phase/ 50Hz 230V | 240V 11.6 : 9.70 | 11.1 : 9.30 996 x 980 x 370 90 1,285 : 1,169 52 (50) : 52 (50) 68 (66) : 67 (65) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,600 / 45 (g/m) -10 to 43 : -15 to 24
Cooling capacity : Heating capacity EER : COP Total power input Indoor Unit
Cooling : Heating
Power source Current Dimensions Net weight Air volume External static pressure Sound pressure level (H/M/L) Sound power level (H/M/L) Number of fan speeds Drain piping Outdoor Unit
Cooling : Heating H×W×D Cooling : Heating Cooling : Heating Cooling : Heating
Power source Current Cooling : Heating Dimensions H×W×D Net weight Air volume Cooling : Heating Sound pressure level Cooling : Heating Sound power level Cooling : Heating Piping connections Liquid / Gas Pipe length min. - max. Elevation difference (OU located lower, OU located higher) Maximum chargeless length Refrigerant at shipping / Additional gas amount Operation ranges Cooling : Heating
Notes: The Rated Capacity, Power Input and Running Current are measured in accordance with AS/NZS 3823 • Cooling: Indoor temperature: 27°C DB/ 19°C WB, Outdoor temperature: 35°C DB/ 24°C WB • Heating: Indoor temperature: 20°C DB/ 15°C WB, Outdoor temperature: 7°C DB/ 6°C WB
22 18
High Static Pressure Slim-line Ducted
14.0KW
12.5KW S-125PF1E5B
S-125PF1E5B
S-140PF1E5B
S-140PF1E5B
U-125PZH2R5
U-125PZH2R8
U-140PZH2R5
U-140PZH2R8
12.5 (3.2 - 14.0) 14.0 (3.2 - 16.0)
12.5 (3.2 - 14.0) 14.0 (3.2 - 16.0)
14.0 (3.3 - 16.0) 16.0 (3.3 - 18.0)
14.0 (3.3 - 16.0) 16.0 (3.3 - 18.0)
42,700 (10,900 - 47,800) 47,800 (10,900 - 54,600)
42,700 (10,900 - 47,800) 47,800 (10,900 - 54,600)
47,800 (11,300 - 54,600) 54,600 (11,300 - 61,400)
47,800 (11,300 - 54,600) 54,600 (11,300 - 61,400)
3.52 : 4.02 3.55 : 3.48
3.52 : 4.02 3.55 : 3.48
3.26 : 3.65 4.30 : 4.38
3.26 : 3.65 4.30 : 4.38
1 Phase/ 50Hz 230V | 240V 1.44 : 1.42 | 1.39 : 1.38 290×1,400×700 45 566 : 566 100 (10 - 150) 39 / 35 / 32 : 39 / 35 / 32 61 / 57 / 54 : 61 / 57 / 54 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.44 : 1.42 | 1.39 : 1.38 290×1,400×700 45 566 : 566 100 (10 - 150) 39 / 35 / 32 : 39 / 35 / 32 61 / 57 / 54 : 61 / 57 / 54 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.50 :1.50 | 1.47 : 1.46 290×1,400×700 45 600 : 600 100 (10 - 150) 40 / 36 / 33 : 40 / 36 / 33 62 / 58 / 55 : 62 / 58 / 55 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.50 :1.50 | 1.47 : 1.46 290×1,400×700 45 600 : 600 100 (10 - 150) 40 / 36 / 33 : 40 / 36 / 33 62 / 58 / 55 : 62 / 58 / 55 3 VP-25
1 Phase/ 50Hz 230V | 240V 15.2 : 14.9 | 14.6 : 14.3 1,416 × 940 × 340 99 2,083 : 1,867 53 (51) : 53 (51) 69 (67) : 69 (67) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
3 Phase/ 50Hz 400V | 415V 5.10 : 5.00 | 4.95 : 4.85 1,416 × 940 × 340 99 2,083 : 1,867 53 (51) : 53 (51) 69 (67) : 69 (67) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
1 Phase/ 50Hz 230V | 240V 18.6 : 19.0 | 17.8 : 18.2 1,416 × 940 × 340 99 2,150 : 1,933 54 (52) : 54 (52) 70 (68) : 70 (68) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
3 Phase/ 50Hz 400V | 415V 6.25 : 6.40 | 6.05 : 6.15 1,416 × 940 × 340 99 2,150 : 1,933 54 (52) : 54 (52) 70 (68) : 70 (68) Ø9.52 / Ø15.88 5 - 85 15, 30 30 R32 3,050 / 45 (g/m) -15 to 46 : -20 to 24
14.0KW
12.5KW S-100PF1E5B
S-125PF1E5B
S-125PF1E5B
S-140PF1E5B
S-140PF1E5B
U-100PZ2R8
U-125PZ2R5
U-125PZ2R8
U-140PZ2R5
U-140PZ2R8
10.0 (3.0 - 11.5) 10.0 (3.0 - 14.0)
12.5 (3.2 - 13.5) 12.5 (3.3 - 15.0)
12.5 (3.2 - 13.5) 12.5 (3.3 - 15.0)
14.0 (3.3 - 15.0) 14.0 (3.4 - 16.0)
14.0 (3.3 - 15.0) 14.0 (3.4 - 16.0)
34,100 (10,200 - 39,200) 34,100 (10,200 - 47,800)
42,700 (10,900 - 46,100) 42,700 (11,300 - 51,200)
42,700 (10,900 - 46,100) 42,700 (11,300 - 51,200)
47,800 (11,300 - 51,200) 47,800 (11,600 - 54,600)
47,800 (11,300 - 51,200) 47,800 (11,600 - 54,600)
3.66 : 4.31 2.73 : 2.32
3.52 : 4.02 3.55 : 3.11
3.52 : 4.02 3.55 : 3.11
3.18 : 3.79 4.40 : 3.69
3.18 : 3.79 4.40 : 3.69
1 Phase/ 50Hz 230V | 240V 1.30 : 1.34 | 1.27 : 1.29 290×1,400 ×700 45 533 : 533 100 (10 - 150) 38 / 34 / 31 : 38 / 34 / 31 60 / 56 / 53 : 60 / 56 / 53 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.44 : 1.42 | 1.39 : 1.38 290×1,400 ×700 45 566 : 566 100 (10 - 150) 39 / 35 / 32 : 39 / 35 / 32 61 / 57 / 54 : 61 / 57 / 54 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.44 : 1.42 | 1.39 : 1.38 290×1,400 ×700 45 566 : 566 100 (10 - 150) 39 / 35 / 32 : 39 / 35 / 32 61 / 57 / 54 : 61 / 57 / 54 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.50 : 1.50 | 1.47 : 1.46 290×1,400 ×700 45 600 : 600 100 (10 - 150) 40 / 36 / 33 : 40 / 36 / 33 62 / 58 / 55 : 62 / 58 / 55 3 VP-25
1 Phase/ 50Hz 230V | 240V 1.50 : 1.50 | 1.47 : 1.46 290×1,400 ×700 45 600 : 600 100 (10 - 150) 40 / 36 / 33 : 40 / 36 / 33 62 / 58 / 55 : 62 / 58 / 55 3 VP-25
3 Phase/ 50Hz 400V | 415V 3.95 : 3.30 | 3.80 : 3.20 996 x 980 x 370 90 1,285 : 1,169 52 (50) : 52 (50) 68 (66) : 67 (65) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,600 / 45 (g/m) -10 to 43 : -15 to 24
1 Phase/ 50Hz 230V | 240V 15.5 : 13.4 | 14.8 : 12.9 996 x 980 x 370 94 1,436 : 1,302 55 (53) : 55 (53) 70 (68) : 70 (68) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,980 / 45 (g/m) -10 to 43 : -15 to 24
3 Phase/ 50Hz 400V | 415V 5.10 : 4.45 | 4.95 : 4.30 996 x 980 x 370 94 1,436 : 1,302 55 (53) : 55 (53) 70 (68) : 70 (68) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,980 / 45 (g/m) -10 to 43 : -15 to 24
1 Phase/ 50Hz 230V | 240V 19.3 : 16.0 | 18.6 : 15.3 996 x 980 x 370 94 1,486 : 1,386 56 (54) : 56 (54) 71 (69) : 71 (69) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,980 / 45 (g/m) -10 to 43 : -15 to 24
3 Phase/ 50Hz 400V | 415V 6.40 : 5.30 | 6.15 : 5.15 996 x 980 x 370 94 1,486 : 1,386 56 (54) : 56 (54) 71 (69) : 71 (69) Ø9.52 / Ø15.88 5 - 50 15, 30 30 R32 2,980 / 45 (g/m) -10 to 43 : -15 to 24
23 19
Wall-Mounted Reverse cycle models
Wireless Remote Controller Included
CZ-RD514C Wired Remote Controller (Optional)
Wired Remote Controller Included
Network Adaptor *5 (Optional)
Network Adaptor *5 (Optional)
Model No
CS-MRZ16VKR
CS-MRZ20VKR
CS-RZ25VKRW
CS-RZ35VKRW
Capacity
1.6kW
2.0kW
2.5kW
3.5kW
Model No
CS-RZ42VKRW
Capacity
4.2kW*
1
CS-RZ50VKRW CS-RZ25VKR CS-RZ60VKRW
5.0kW*
1
6.0kW*
2
CS-RZ71VKRW
7.1kW* *
2 3
Ultra Slim Ducted Model No CS-Z25UD3RAW CS-Z35UD3RAW CS-Z5OUD3RAW CS-Z6OUD3RAW Capacity
2.5kW
3.5kW
5.0kW*
1
6.0kW*
2
4-Way Mini Cassette Model No CS-Z25UB4RAW CS-Z35UB4RAW CS-Z50UB4RAW CS-Z60UB4RAW
Panel CZ-BT30EW
Wireless Remote Controller Included
CZ-RD52CP Wired Remote Controller (Optional)
Network Adaptor*5 (Optional)
Wireless Remote Controller Included
CZ-RD514C Wired Remote Controller (Optional)
Network Adaptor *5 (Optional)
Capacity
2.5kW
3.5kW
5.0kW*
Model No
CS-Z25UFRAW
CS-Z35UFRAW
CS-Z50UFRAW
Capacity
2.5kW
3.5kW
5.0kW*
1
Floor Console
*5
20 22
Wireless LAN Remote Control for Internet Connection required optional network adaptor. Indoor temperature display and some special function are not available through the App for all models.
1
6.0kW*
2
Multi-Split Air Conditioning System
Space-saving installation with less outdoor units required
Outdoor unit connects to each indoor unit independently
Maximum height up to 15 meters for indoor and outdoor unit.
The multi-split system accommodates long pipelines up to 80 meters
Piping can be extended up to 80 meters.*
* Applicable to CU-5Z100VBR
21 23
MULTI-SPLIT AIR CONDITIONING SYSTEM
Specifications Indoor Units Combination Range
Indoor Units: Possible Combination Patterns
Models
Must be within capacity range
Refrigerant Pipe Diameter Indoor Unit
Liquid Side (mm)
Gas Side (mm)
Pipe Extension
Indoor Unit Combinations
Maximum Maximum Maximum Type Pipe Pipe Cassette WallChargeless Additional Maximum Length Length Mounted (4-Way) Gas Height Capacity Length (1 room) (Total) [kW class]
CU-2Z52VBR
PORT
A
PORT
2
5.2kW *4
rooms
B
1.6
or
2.0
or
2.5
or
3.5
3.2 to 7.7 kW
5.0
4.2 or
or
* Either unit
1.6
or
2.0
or
2.5
or
3.5
ø 6.35
2.0
ø 9.52
2.5 20 m
5.0
4.2 or
A
30 m
20 m
15 g/m
10 m 3.5
or
* Either unit
Room
Dimensions (HxWxD): 619 x 824(+70) x 299 mm Weight: 39 kg
Make sure to keep combinations within this range.
* At least two indoor units must be connected.
B
ø 6.35
4.2
ø 9.52
5.0
CU-3Z54VBR
1.6 Room
A
PORT
A
1.6
or
2.0
or
2.5
or
3.5
or
3
PORT
B
or
2.0
or
2.5
or
3.5
4.5 to 9.5 kW
5.0
4.2 or
or
* Either unit
PORT
5.4kW *4 Dimensions (HxWxD): 795 x 875(+95) x 320 mm Weight: 71 kg
C
1.6
or
2.0
ø 9.52 2.0
or
* Either unit
1.6
ø 6.35
5.0
4.2
Up to rooms
Floor Console
1.6
Room
Up to
Ultra Slim Ducted
2.5 Room
B
ø 6.35
ø 9.52
25 m
50 m
30 m
20 g/m
15 m 3.5
or
2.5
or
3.5
5.0
4.2 or
or
4.2
* Either unit
Make sure to keep combinations within this range.
* At least two indoor units must be connected.
Room
C
ø 6.35
ø 9.52 5.0
CU-4Z71VBR Room
A
PORT
A
1.6
or
2.0
or
2.5
or
3.5
or
or
ø 9.52 2.0
6.0
5.0
4.2
1.6
ø 6.35
or
* Either unit
PORT
Up to
B
1.6
or
2.0
or
2.5
or
3.5
or
4.5 to 11.5 kW
6.0
5.0
4.2 or
or
* Either unit
4
rooms
PORT
7.1kW *4
C
1.6
or
2.0
or
2.5
or
3.5
or
or
or
D
1.6
or
2.0
C
or
2.5
or
3.5
6.0
5.0
4.2 or
or
or
* Either unit
Dimensions (HxWxD): 795 x 875(+95) x 320 mm Weight: 72 kg
ø 6.35
2.5
ø 9.52 25 m
Room
* Either unit
PORT
B
60 m
30 m
20 g/m
15 m
3.5
6.0
5.0
4.2
Room
Make sure to keep combinations within this range.
ø 6.35
ø 9.52
ø 6.35
ø 9.52
4.2
5.0 Room
D
6.0
* At least two indoor units must be connected.
*4 To enable demand response management, an optional accessory needs to be installed (CZ-CAP2)
Outdoor Up to 2 rooms CU-2Z52VBR
22 24
Up to 3 rooms CU-3Z54VBR
Up to 4 rooms CU-4Z71VBR
Multi-Split Air Conditioning System MULTI-SPLIT AIR CONDITIONING SYSTEM
Specifications Indoor Units Combination Range
Indoor Units: Possible Combination Patterns
Models
Must be within capacity range
Refrigerant Pipe Diameter Indoor Unit
Pipe Extension
Indoor Unit Combinations
Maximum Maximum Maximum Type Pipe Pipe Cassette WallChargeless Additional Maximum Length Length Mounted (4-Way) Gas Height Capacity Length (1 room) (Total) [kW class]
Liquid Side (mm)
Gas Side (mm)
ø 6.35
ø 9.52
CU-4Z80VBR
Ultra Slim Ducted
Floor Console
1.6 Room
A
2.0 PORT
A
PORT
Up to
B
4
rooms
PORT
C
8.0kW *4
PORT
D
1.6
or
2.0
or
2.5
or
3.5
4.2 or
0 6.0
5.0 or
or
7.1 or
* Either unit
1.6
or
2.0
or
2.5
or
3.5
0 6.0
5.0
4.2 or
or
or
7.1
4.5 to 14.7 kW
2.5 Room
B
3.5
or
1.6
or
2.0
25 m
or
2.5
or
3.5
0 6.0
5.0
4.2 or
or
or
7.1 or
* Either unit
1.6
or
2.0
or
2.5
or
3.5
or
0 6.0
5.0
4.2 or
or
7.1 or
Room Make sure to keep combinations within this range.
C
15 m 4.2
ø 6.35
ø 9.52
6.0
ø 6.35
ø 9.52 7.1
Room
PORT
B
1.6
or
2.0
or
2.5
or
3.5
5.0
4.2 or
0 6.0
or
or
or
2.0
or
2.5
or
3.5
0 6.0
5.0
4.2 or
or
PORT
or
7.1 or
* Either unit
C
PORT
D
PORT
E
1.6
or
2.0
or
2.5
or
3.5
or
0 6.0
5.0
4.2 or
or
2.0
or
2.5
or
3.5
or
Room
B
Room
C
or
or
or
7.1 or
* Either unit
1.6
or
2.0
or
2.5
or
3.5
0 6.0
5.0
4.2 or
or
or
ø 6.35
ø 9.52
2.5 25 m
7.1
0 6.0
5.0
4.2 or
1.6
ø 9.52
2.0
4.5 to 18.3 kW
* Either unit
1.6
ø 6.35
or
* Either unit
1.6
A
7.1
Up to
Dimensions (HxWxD): 999 x 940 x 340 mm Weight: 81 kg
20 g/m
* At least two indoor units must be connected.
A
10.0kW *4
45 m
5.0
D
PORT
5
70 m
* Either unit
CU-5Z100VBR
rooms
ø 9.52
* Either unit
Room Dimensions (HxWxD): 999 x 940 x 340 mm Weight: 80 kg
ø 6.35
Make sure to keep combinations within this range.
80 m
45 m
20 g/m
3.5
ø 6.35
ø 9.52 4.2
Room
D
ø 6.35
5.0
ø 9.52
6.0
7.1 or
* Either unit
15 m
Room
E
ø 6.35
ø 9.52 7.1
* At least two indoor units must be connected.
*4 To enable demand response management, an optional accessory needs to be installed (CZ-CAP2)
Accessories
CZ-MA1P *1 CZ-MA1P is to be used to reduce the connection size on the indoor unit from 1/2’’ to 3/8’’.
CZ-MA2P *2 CZ-MA2P is to be used to increase the connection size on the outdoor unit from 3/8’’ to 1/2’’.
CZ-MA3P *3 CZ-MA3P is to be used to reduce the connection size on the indoor unit from 5/8’’ to 1/2’’.
CZ-CAP2 *4 Demand response module CZ-CAP2.
CZ-TACG1 *5 Network Adaptor (Optional)
Outdoor Up to 4 rooms CU-4Z80VBR g
C
Up to 5 rooms CU-5Z100VBR Heating Possible
Cooling Possible
C
25
23
MULTI-SPLIT AIR CONDITIONING SYSTEM
Indoor units
Cooling Heating
Wall-Mounted Model Capacity
kW
CS-MRZ16VKR
CS-MRZ20VKR
CS-RZ25VKRW
CS-RZ35VKRW
1.6
2.5kW Class 2.0
2.5
3.5
Power Source
CS-RZ50VKRW
3.23. 4.2
CS-RZ60VKRW
5.05.0kW Class
CS-RZ71VKRW
6.0
7.1
Single Phase 240V, 50Hz Cooling
Noise (H/L)
CS-RZ42VKRW
41/27
42/27
42/27
46/28
47/33
46/36
48/38
51/39
41/29
42/29
42/29
46/31
46/37
46/35
48/38
51/39
57/43
58/43
58/43
62/44
63/49
62/52
64/54
67/55
57/45
58/45
58/45
62/47
62/53
62/51
64/54
67/55
dB(A)
Heating Cooling dB Heating
Airflow
Dimensions
Cooling/ Heating
L/s
183/192
190/198
190/193
195/213
198/213
332/338
353/353
385/395
Height
mm
290
290
290
290
290
302
302
302
Width
mm
799
799
799
799
799
1,102
1,102
1,102
Depth
mm
197
197
197
197
197
244
244
244
8
8
8
8
8
12
13
13
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 9.52
ø 9.52
ø 9.52
ø 9.52
ø 9.52*1
ø 9.52*1
ø 12.70*2
ø 12.70*2*3
kg
Net Weight
Refrigerant Pipe Diameter
Liquid Side
mm
Gas Side
mm
Cooling Heating
Ultra Slim Ducted Model Capacity
kW
4-Way Mini Cassette
CS-Z25UD3RAW CS-Z35UD3RAW CS-Z50UD3RAW CS-Z60UD3RAW CS-Z25UB4RAW CS-Z35UB4RAW CS-Z50UB4RAW CS-Z60UB4RAW CS-Z25UFRAW
CS-Z35UFRAW
CS-Z50UFRAW
2.5
2.5
3.5
5.0
6.0
Noise (H) Airflow
Dimensions
Cooling
26
6.0
2.5
3.5
5.0
35/29
35/28
41/31
43/32
36/27
36/28
40/30
45/34
40/27
41/28
46/33
Heating
36/29
37/29
41/32
43/34
37/30
39/30
41/31
47/34
40/27
41/27
48/35
Cooling
dB
51
51
57
59
52
52
56
61
56
57
62
Heating
52
53
57
59
53
55
57
63
56
57
64
Cooling/Heating
L/s
175/175
187/187
255/255
262/262
175/180
175/195
192/197
237/253
163/173
170/182
198/227
Height
mm
200
200
200
200
260
260
260
260
600
600
600
Width
mm
750
750
750
750
575
575
575
575
750
750
750
Depth
mm
640
640
640
640
575
575
575
575
207
207
207
kg
19
19
19
19
18
18
18
18
13
13
13
Liquid Side
mm
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
Gas Side
mm
ø 9.52
ø 9.52
ø 9.52*1
ø 12.70*2
ø 9.52
ø 9.52
ø 9.52*1
ø 12.70*2
ø 9.52
ø 9.52
ø 9.52*1
*1 CZ-MA1P is to be used to reduce the connection size on the indoor unit from 1/2’’ to 3/8’’. *2 CZ-MA2P is to be used to increase the connection size on the outdoor unit from 3/8’’ to 1/2’’. *3 CZ-MA3P is to be used to reduce the connection size on the indoor unit from 5/8’’ to 1/2’’.
24
5.0
dB(A)
Net Weight
Refrigerant Pipe Diameter
3.5 Single Phase 240V, 50Hz
Power Source Noise (H/L)
Floor Console
Multi-Split Air Conditioning System
MULTI-SPLIT AIR CONDITIONING SYSTEM
Outdoor Units
Cooling Heating
Model
(50Hz)
Indoor Units Combination
CU-2Z52VBR 2.50kW + 2.50kW
CU-3Z54VBR 1.60kW + 1.60kW + 2.00kW
Power Source
CU-4Z71VBR 1.60kW + 1.60kW +1.60kW + 2.00kW
CU-4Z80VBR
CU-5Z100VBR
2.00kW + 2.00kW + 2.00kW + 2.00kW
2.00kW + 2.00kW + 2.00kW + 2.00kW + 2.00kW
Single Phase 240V, 50Hz
Cooling Operation
Capacity (min-max)
kW
5.20 (1.50-6.00)
5.40 (1.80-7.30)
7.10 (1.90-8.80)
8.00 (2.30-9.20)
10.00 (2.30-11.50)
Maximum Connectable Capacity
kW
7.7
9.5
11.5
14.7
18.3
Maximum Connectable Indoors
Units
2
3
4
4
5
5.9
5.1
7.4
8.9
11.8
kW
1.35 (0.25-1.62)
1.12 (0.36-2.18)
1.66 (0.34-2.47)
1.98(0.42-2.87)
2.60 (0.43-3.59)
W/W
3.79 / 3.85
4.74 / 4.82
4.23 / 4.28
4.00 / 4.04
3.81 / 3.85
dB(A)
51
48
49
51
53
Sound Power Level
dB
66
62
63
67
69
Capacity
kW
6.10 (1.10-7.20)
7.00 (1.60-9.00)
8.50 (3.00-10.70)
9.40 (3.00-11.60)
12.00 (3.40-14.50)
6.2
6.8
8.6
9.3
12.1
kW
1.43 (0.21-1.90)
1.54 (0.32-2.63)
1.95 (0.50-2.72)
2.03 (0.50-3.42)
2.76 (0.58-4.02)
W/W
4.21 / 4.27
4.49 / 4.55
4.32 / 4.36
4.58 / 4.63
4.31 / 4.35
dB(A)
53
49
51
52
56
dB
68
63
65
68
72
Maximum Current
A
11.5
15.2
15.6
19.0
21.3
Starting Current
A
6.4
7.0
8.8
9.7
12.5
Compressor Output
W
900
1300
1300
1700
1700
Height
mm
619
795
795
999
999
Width
mm
824 (+70)
875 (+95)
875 (+95)
940
940
Depth
mm
299
320
320
340
340
kg
39
71
72
80
81
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Running Current Electrical Data
A
Power Input (min-max) AEER/EER Sound Pressure Level
Noise (H)
Heating Operation
Running Current Electrical Data
A
Power Input (min-max) ACOP/COP Sound Pressure Level
Noise (H) Sound Power Level
Dimensions
Net Weight Power Supply Pipe Length Range (1 room)
m
3~20
3~25
3~25
3~25
3~25
Maximum Pipe Length (Total) *
m
30
50
60
70
80
Refrigerant Pipe Diameter
Liquid Side
mm
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
Gas Side
mm
ø 9.52
ø 9.52
ø 9.52
ø 9.52
ø 9.52
-10~+46
-10~+46
Cooling
Degree (°C)
-10~+46
Heating
Degree (°C)
-15~+24*1
-10~+46
-10~+46
Operating Range 1
-15~+24*
1
-15~+24*
1
-15~+24*
-15~+24*1
* Additional Gas might be required for some models. Refer to Page 38 for information on Additional Gas. Rating Conditions Cooling Inside air temperature Outside air temperature
Heating
27ºC DB /19ºC WB
20ºC DB
35ºC DB
7ºC DB /6ºC WB
27
25
Mini-VRF LE Series
2-PIPE Mini-VRF 2-PIPE Mini-VRF LE Series LE Series
High external static pressure 35Pa
High External Static Pressure
35Pa
High External Static Pressure LE 1L
E2
35Pa
When unit is installed on a narrow balcony and exposed to the sun, the fence at the front side would restrict hot air from being discharged. Heat accumulated in an enclosure can cause over-heating. This could potentially result in damage or shorten the product’s life span. A high external static pressure sends the air further away from the outdoor unit and through the fence. This provides better air circulation and distribution.
LE series - High pressure
35
35
Heat discharged Pa
But with a high pressure of 35Pa, hot air is sent further away preventing overheating inside the outdoor unit enclosure.
LE series fan
The new LE Series fan has ribs extending near the blade tips, in a structure that resists deformation. During high electrostatic pressure, this blade shape suppresses disruptions in the airflow, and a high air pressure of 35 Pa discharges the hot air a sufficient distance.
Pa
Long piping design length for greater design flexibility High external static pressure 35Pa
LE 1
LE 2 LE1
LE2
Adaptable to various When unit is installed building types and sizeson a narrow balcony and exposed to the sun, the fence at the front side would restrict hot air from being discharged. Heat accumulated in an enclosure can cause over-heating. This could
potentially result in damage or shorten the product’s life span. A high external static pressure sends the air Height difference Actual piping length 150m Actual piping 150m further away from the outdoor unit and through the fence. This provides betterlength air circulation and distribution. 1 50m*
(equivalent piping length 175m)
Max. total piping length:300m
LE series - High pressure
Level difference between indoor units 15m
LE 1air is sent further away But with a high pressure of 35Pa, hot preventing overheating inside the outdoor unit enclosure.
(equivalent piping length 175m)
Height difference 50m*1
Level difference between indoor units 15m
Max. total piping length:180m LE 2
*1: 40m if the outdoor unit is below the indoor unit.
Refrigerant chargeless up to 50m
LE 2
Up to 50m of piping without additional gas charging makes installation easy and hassle-free.
[ Sample piping lay-out ]
Chargeless A 50m pipe length is suf for most residential and small business Heat discharged Max. total piping length: 50m buildings. When total piping length exceeds 50m, additional refrigerant charge is required.
35
Pa
Charge Max. total piping length: 180m (Actual length: 150m)
Blue fin condenser
LE 1
3
5 P of the heat The anti-corrosion Blue Fin treatment a exchanger provides greater resistance against corrosion. All models are equipped with Blue Fin condenser. LE series fan
26
The new LE Series fan has ribs extending near the blade tips, in a structure that resists deformation. During high electrostatic pressure, this blade shape suppresses disruptions in the airflow, and a high air pressure of 35 Pa discharges the hot air a sufficient distance.
Heat exchanger blue fin condenser )
[ Rear view ]
LE 2
Mini-VRF LE Series Compact design
L E1
Long piping design length for greater design flexibility
LE1
Also, since Mini VRF LE Series is a single unit, it is possible to install the unit in more Adaptable to various various places compared to the Single building types and sizes Split system. Actual piping length 150m (equivalent piping length 175m)
Short height of 996mm In addition to raising ef
LE2
y, we have
made thelength:300m outdoor unit more compact. It Max. total piping can now be installed in places that were previously too small.
Single Split
Height difference 50m*1
LE 1
LE 2
Mini-FSV Height
Actual piping length 150m (equivalent piping length 175m)
Short Level difference Height between indoor 996mm units 15m
LE 2
difference 50m*1
[ LE 2 ] [12.1kW LE1]
Max. total piping length:180m
Level difference 1330mm between indoor units 15m
996mm
Can be installed in the small space
LE 2
980mm 370mm *1: 40m if the outdoor unit is below the indoor unit.
Up to 13 indoor units connectable
LE 1
LE 2
An expansion from Panasonic FSV line up, the mini FSV is compatible with the same indoor units and controls as the rest of the FSV range.
(LE1)
LE1
Compact design
/ 9* (LE2)
LE1
LE 2
Also, since Mini VRF LE Series is a single unit, it is possible to install the unit in more LE2 various places compared to the Single Split system.
Refrigerant pipe Single Split
Control line
Mini-FSV
* Use any of the FSV indoor models. Depending on the size or type of indoor unit, piping size shall be changed. Please refer technical documents for details. * Diversity ration 50-130% * 15.5kW only; 12.1kW for 7 units, 14.0kW for 8 units.
Short height of 996mm
LE2
y, we have In addition to raising ef Energy savings design made the outdoor unit more compact. It can now be installed in places that were previously too small. 6
[ LE 2 ]
Short Height 996mm
2
996mm
1
Panasonic A large-capacity inverter compressor has been adopted. The inverter Can be installed in the small space Inverter Compressor compressor is superior in performance partial-load capacity. 980mm with improved 370mm
2
Printed Circuit Board
The number of PCB is 2 pieces for making maintenance easier.
3
Accumulator
A large accumulator has been adopted to maintain compressor reliability because of the increased refrigerant quantity, which allows an extended max piping length.
4
DC Fan Motor
Checking load and outside temperature, the DC motor is controlled for optimum air volume.
5
Newly Designed Fan
The newly designed fan blades have been developed to inhibit air turbulence and to increase efficiency. As fan diameter has been increased its size, the air volume has been increased whilst maintaining a same sound LE1 level.LE 2
4
7
Up to 13 indoor units connectable 3
[12.1kW LE1]
LE 11330mm LE 2
6
Heat Exchanger &
The heat exchanger size and the copper tube sizes in the heat exchanger have been redesigned to increase efficiency.
Tubes with the same indoor units and controls as An expansion from Panasonic FSV line up, the mini FSVCopper is compatible
the rest of 5the FSV range.
1
7
Oil Separator
A centrifugal separator has been adopted to improve oil separation efficiency and reduce refrigerant pressure loss.
Up to 13 (LE1) / 9* (LE2)
LE1
indoor units
Wide operating range LE2
•C ooling operation is possible even when outdoor temperature is as low as -10°C DB. •C ooling operation is possible even when outdoor
LE 1
Refrigerant pipe
LE 2
Control line
temperature is as high as 46°C DB. •H eating operation is possible * Use any of the FSV indoor models. Dependingeven on thewhen size oroutdoor type of indoor unit, piping size shall be changed. Please refer technical documents for details. * Diversity ration 50-130% is as low as -20°C WB. temperature * 15.5kW only; 12.1kW for 7 units, 14.0kW for 8 units.
The remote controller temperature can be set from 18°C up to 30°C (Cooling), 16°C up to 30°C (Heating)*1.
Heating: -20¡ C WB ~ 18¡C WB Cooling: -10¡ C DB ~ 46¡C DB * For further information pleaserefer to the capacity tables inthe Technical Data Book.
*1 Depending on the type of remote controller.
27
Mini-VRF LE Series
2-PIPE Mini-VRF LE2 Series kW
12.1
12.1
14.0
14.0
15.5
15.5
U-4LE2R5
U-4LE2R8
U-5LE2R5
U-5LE2R8
U-6LE2R5
U-6LE2R8
230/240V/1-phase/50Hz
400/415V/3-phase/50Hz
230/240V/1-phase/50Hz
400/415V/3-phase/50Hz
230/240V/1-phase/50Hz
400/415V/3-phase/50Hz
Model name Power supply Voltage
230V
240V
kW
Cooling
BTU/h
Capacity
kW
Heating
BTU/h
400V
415V
230V
240V
400V
415V
230V
240V
400V
415V
12.1
12.1
14.0
14.0
15.5
15.5
41,300
41,300
47,800
47,800
52,900
52,900
12.5
12.5
16.0
16.0
16.5
16.5
42,700
42,700
54,600
54,600
56,300
56,300
Cooling
W/W
4.50
4.50
4.06
4.06
3.73
3.73
Heating
W/W
5.19
5.19
4.60
4.60
4.27
4.27
Dimensions (H/W/D)
mm
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
Net weight
kg
106
106
106
106
106
EER/COP
Electrical ratings
Cooling Heating
A
12.70
12.20
4.17
4.02
16.30
15.60
5.30
5.11
19.40
18.60
6.37
Power input
kW
2.69
2.69
2.69
2.69
3.45
3.45
3.45
3.45
4.15
4.15
4.15
4.15
Running current
A
11.60
11.20
3.78
3.64
16.60
15.90
5.34
5.15
18.20
17.50
5.93
5.71
kW
2.41
2.41
2.41
2.41
3.48
3.48
3.48
3.48
3.86
3.86
3.86
Power input
Starting current
A
Refrigerant amount at shipment Piping connection
106
Running current
1
1
1
1
1
6.14
3.86 1
m3 / h
4,140
4,140
4,320
4,320
4,440
4,440
L/s
1,150
1,150
1,200
1,200
1,233
1,233
kg
Gas pipe
mm (inches)
Liquid pipe
mm (inches)
Ambient temperature operating range
R410A 6.70
R410A 6.70
R410A 6.70
R410A 6.70
R410A 6.70
R410A 6.70
Ø15.88 (Ø5/8)
Ø15.88 (Ø5/8)
Ø15.88 (Ø5/8)
Ø15.88 (Ø5/8)
Ø15.88 (Ø5/8)
Ø15.88 (Ø5/8)
Ø9.52 (Ø3/8)
Ø9.52 (Ø3/8)
Ø9.52 (Ø3/8)
Ø9.52 (Ø3/8)
Ø9.52 (Ø3/8)
Ø9.52 (Ø3/8)
Cooling:-10˚CDB~+46˚CDB, Heating:-20˚CWB~+18˚CWB
Cooling:-10˚CDB~+46˚CDB, Heating:-20˚CWB~+18˚CWB
Cooling:-10˚CDB~+46˚CDB, Cooling:-10˚CDB~+46˚CDB, Cooling:-10˚CDB~+46˚CDB, Cooling:-10˚CDB~+46˚CDB, Heating:-20˚CWB~+18˚CWB Heating:-20˚CWB~+18˚CWB Heating:-20˚CWB~+18˚CWB Heating:-20˚CWB~+18˚CWB
Sound Normal mode pressure level Silent mode (Cooling)
dB(A)
52.0
52.0
53.0
53.0
54.0
54.0
dB(A)
45.0
45.0
46.0
46.0
47.0
47.0
Sound power level (Cooling)
dB
69.0
69.0
71.0
71.0
73.0
73.0
Global remarks
Normal mode
* As a foot print.
Rated conditions:
Cooling
Heating
Indoor air temperature
27˚C DB / 19˚C WB
20˚C DB
Outdoor air temperature
35˚C DB
7˚C DB / 6˚C WB
Dimensions U-4LE2R5 / U-4LE2R8 U-5LE2R5 / U-5LE2R8 U-6LE2R5 / U-6LE2R8 Air intake
Mounting hole (4-R6.5), anchor bolt : M10 (24.5) 18
350
170
(56)
Refrigerant tubing (liquid tube), flared connection (Ø9.52) Refrigerant tubing (gas tube), flared connection (Ø15.88)
13
Air discharge
980
Electrical wiring port (Ø13)
49
Electrical wiring port (Ø22) Electrical wiring port (Ø27)
A VIEW
Electrical wiring port (Ø35)
1
4×Ø32 holes (holes for drain)
61
Refrigerant tubing port 20
370
330
160
160
36
Air intake
200
(24)
660
230
450
160
412.5
(10)
A VIEW
When using a drain pipe, install the drain socket (field supply) on to the drain port.Seal the other drain port with the rubber cap.
370
8
36
60 30
4
4
6 60
89
5
60
7 8
Z VIEW
5 7
16 173
39 48
35
82
121
7
82
6
Air intake
19
39
29
48
320
996
3 5
35
28
Air discharge
121
2
47
6
51
35
8
120
980
Air intake
61
23°
4 42
74 100
Z VIEW Unit: mm
Mini-VRF LE Series
2-PIPE Mini-VRF LE1 Series 22.4
25.0
Model name
kW
U-8LE1R8
U-10LE1R8
Power supply
400/415V/3-phase/50Hz 380/400V/3-phase/60Hz
Voltage
400V kW
Cooling
BTU/h
Capacity
EER/COP
BTU/h
415V 25.0
76,500
85,300
25.0
28.0
85,300
95,600 3.31
Cooling
W/W
3.80
Heating
W/W
4.02
3.93
mm
1,500 x 980 x 370
1,500 x 980 x 370
Dimensions (H/W/D) Net weight Electrical ratings
400V
22.4
kW
Heating
400/415V/3-phase/50Hz 380/400V/3-phase/60Hz
415V
kg Cooling Heating
132
133
Running current A
9.15
8.80
11.70
Power input
5.89
5.89
7.55
7.55
Running current A
9.65
9.30
11.10
10.70
Power input
6.22
6.22
7.13
Starting current
kW kW A
11.30
7.13
1
1 9,600
m3 / h
9,000
L/s
2,500
2,666
Refrigerant amount at shipment
kg
R410A 6.30
R410A 6.60
Piping connection
Gas pipe
mm (inches)
Ø19.05 (Ø3/4)
Ø22.22 (Ø7/8)
Liquid pipe
mm (inches)
Ø9.52 (Ø3/8)
Ø9.52 (Ø3/8)
Cooling:-10˚CDB~+46˚CDB, Heating:-20˚CWB~+18˚CWB
Cooling:-10˚CDB~+46˚CDB, Heating:-20˚CWB~+18˚CWB
Air ow rate
Ambient temperature operating range Sound Normal mode pressure level Silent mode (Cooling) Sound power level (Cooling) Normal mode
Global remarks
dB(A)
60.0
62.0
dB(A)
53.0
55.0
dB
81.0
83.0 * As a foot print.
Rated conditions:
Cooling
Heating
Indoor air temperature
27˚C DB / 19˚C WB
20˚C DB
Outdoor air temperature
35˚C DB
7˚C DB / 6˚C WB
Dimensions U-8LE1R8 / U-10LE1R8
Dimensions : U-8LE1H7 / U-10LE1H7 660 200
2
160
160
350
3
A
36
4 5 6 7 8
20
370 330 170
230
Air discharge
13
For U-10LE1H7 The tubing of the gas main has a diameter of ø22.22, but the connection to the service valve of the outdoor unit has a diameter of ø19.05, so a flare has to be used. Consequently, be sure to use the enclosed joint tube B and joint tube A in making connections (braze).
1
980
4×ø 32 holes (holes for drain) When using a drain pipe, install the drain socket (field supply) onto the drain port. Seal the other drain port with the rubber cap.
16
160
412.5
(10)
Mounting hole (4-R6.5), anchor bolt : M10 Refrigerant tubing (liquid tube), ared connection (ø9.52) for 8-10 HP finally. Refrigerant tubing (gas tube), ared connection (ø19.05) Refrigerant tubing port Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35)
47.5
50 62.5
75.5
1
Air intake
370
980
A VIEW
2
Air intake
6
8
47
5 7
35
Air discharge
1500
51
3
35
8
30
4
16
7
42
39
Z VIEW
60 89
60
4
74 100
8
121 48 82
469
48
39
7
60
121
82
29
6
36
35
5
173 120
43
5 6
4
Z VIEW Unit: mm
29
VRF Indoor
VRF Indoor Units Range Wide choice of models depending on the indoor requirements Class Class 22 22 Cooling/Heating Cooling/Heating Capacity Capacity
Type
kW kW 2.2/2.5 2.2/2.5 BTU/h BTU/h 7,500/8,500 7,500/8,500
28 28
36 36
45 45
56 56
60 60
73 73
90 90
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
2.8/3.2 2.8/3.2 9,600/11,000 9,600/11,000
3.6/4.2 3.6/4.2 12,000/14,000 12,000/14,000
4.5/5.0 4.5/5.0 15,000/17,000 15,000/17,000
5.6/6.3 5.6/6.3 19,000/21,000 19,000/21,000
6.0/7.1 6.0/7.1 20,400/24,200 20,400/24,200
7.3/8.0 7.3/8.0 25,000/27,000 25,000/27,000
9.0/10.0 9.0/10.0 30,000/34,000 30,000/34,000
S-60MF2E5A S-60MF2E5A
S-73MF2E5A S-73MF2E5A
S-60MZ1H4A S-60MZ1H4A
S-73MZ1H4A S-73MZ1H4A
F2 F2type type
Mid MidStatic StaticDucted Ducted S-22MF2E5A S-22MF2E5A
S-28MF2E5A S-28MF2E5A
S-36MF2E5A S-36MF2E5A
S-45MF2E5A S-45MF2E5A
S-56MF2E5A S-56MF2E5A
S-22MM1E5A S-22MM1E5A
S-28MM1E5A S-28MM1E5A
S-36MM1E5A S-36MM1E5A
S-45MM1E5A S-45MM1E5A
S-56MM1E5A S-56MM1E5A
S-22MZ1H4A S-22MZ1H4A
S-28MZ1H4A S-28MZ1H4A
S-36MZ1H4A S-36MZ1H4A
S-45MZ1H4A S-45MZ1H4A
S-56MZ1H4A S-56MZ1H4A
S-90MF2E5A S-90MF2E5A
M1type type M1
Slim SlimLow LowStatic Static Ducted Ducted1 Z1type type Z1
Slim Slim&&Narrow Narrow Ducted Ducted1 E2 E2type type
High HighStatic StaticDucted Ducted// Energy EnergySaving SavingHighHighFresh FreshAir AirDucted Ducted1 E1 E1type type
High HighStatic StaticDucted Ducted1
S-90ME1R5A S-90ME1R5A
(class (classofof45-106) 45-106) K2 K2type type
Wall WallMounted Mounted
U2 U2type type
S-73MK2E5A S-73MK2E5A
S-22MK2E5A S-22MK2E5A
S-28MK2E5A S-28MK2E5A
S-36MK2E5A S-36MK2E5A
S-45MK2E5A S-45MK2E5A
S-56MK2E5A S-56MK2E5A
S-22MU2E5A S-22MU2E5A
S-28MU2E5A S-28MU2E5A
S-36MU2E5A S-36MU2E5A
S-45MU2E5A S-45MU2E5A
S-56MU2E5A S-56MU2E5A
S-22MY2E5A S-22MY2E5A
S-28MY2E5A S-28MY2E5A
S-36MY2E5A S-36MY2E5A
S-45MY2E5A S-45MY2E5A
S-56MY2E5A S-56MY2E5A
S-22ML1E5 S-22ML1E5
S-28ML1E5 S-28ML1E5
S-36ML1E5 S-36ML1E5
S-45ML1E5 S-45ML1E5
S-56ML1E5 S-56ML1E5
S-73ML1E5 S-73ML1E5
S-28MD1E5 S-28MD1E5
S-36MD1E5 S-36MD1E5
S-45MD1E5 S-45MD1E5
S-56MD1E5 S-56MD1E5
S-73MD1E5 S-73MD1E5
S-36MT2E5A S-36MT2E5A
S-45MT2E5A S-45MT2E5A
S-56MT2E5A S-56MT2E5A
S-73MT2E5A S-73MT2E5A
**
4-PIPE 4-PIPECassette Cassette
Panel PanelNo. No.CZ-KPU3 CZ-KPU3 Panel PanelNo. No.CZ-KPU3A CZ-KPU3A
S-60MU2E5A S-60MU2E5A
S-73MU2E5A S-73MU2E5A
Y2 Y2type type
4-PIPE 4-PIPEMini MiniCassette Cassette1 Panel PanelNo. No.CZ-KPY3AW CZ-KPY3AW L1type type L1
2-PIPE 2-PIPECassette Cassette1
Panel PanelNo. No.CZ-02KPL2 CZ-02KPL2 Panel PanelNo. No.CZ-03KPL2 CZ-03KPL2 (Only (Onlyfor forS-73ML1E5) S-73ML1E5) D1type type D1
1-PIPE 1-PIPECassette Cassette1 Panel PanelNo. No.CZ-KPD2 CZ-KPD2
T2 T2type type
Ceiling Ceiling1
P1type type P1
Floor FloorStanding Standing1 S-22MP1E5 S-22MP1E5
S-28MP1E5 S-28MP1E5
S-36MP1E5 S-36MP1E5
S-45MP1E5 S-45MP1E5
S-56MP1E5 S-56MP1E5
S-71MP1E5 S-71MP1E5
S-22MR1E5 S-22MR1E5
S-28MR1E5 S-28MR1E5
S-36MR1E5 S-36MR1E5
S-45MR1E5 S-45MR1E5
S-56MR1E5 S-56MR1E5
S-71MR1E5 S-71MR1E5
R1type type R1
Concealed ConcealedFloor Floor Standing Standing1
* Only for High Static Ducted ** Only for CZ-KPU3A 1 Not a stock item, available on request with longer lead time
30
S-90MU2E5A S-90MU2E5A
Indoor Unit VRF Indoor
106 106
112 112
140 140
160 160
180 180
224 224
280 280
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
Cooling/Heating Cooling/Heating
10.6/11.4 10.6/11.4 36,000/39,000 36,000/39,000
11.2/12.5 11.2/12.5 38,200/42,700 38,200/42,700
14.0/16.0 14.0/16.0 47,800/54,600 47,800/54,600
16.0/18.0 16.0/18.0 54,600/61,500 54,600/61,500
18.0/20.0 18.0/20.0 61,400/68,200 61,400/68,200
22.4/25.0 22.4/25.0 76,400/85,300 76,400/85,300
28.0/31.5 28.0/31.5 95,500/107,500 95,500/107,500
S-106MF2E5A S-106MF2E5A
S-140MF2E5A S-140MF2E5A
Wireless Wirelessremote remotecontrol control
Type Typewith with built-in built-in sensor sensor
Type Typewith with separately separately Functions Functions installed installed sensor sensor
••
S-160MF2E5A S-160MF2E5A
•• ••
self-diagnosing Auto fan
Mild dry
Auto restart
DC motor
DC motor
self-diagnosing Auto fan
Mild dry
Auto restart
DC motor
DC motor Drain pump
self-diagnosing Auto fan
DC motor
High Fresh Air self-diagnosing Auto fan
S-180ME2E5 S-180ME2E5**
S-112ME1R5A S-112ME1R5A
S-140ME1R5A S-140ME1R5A
S-224ME2E5 S-224ME2E5
DC motor
S-280ME2E5 S-280ME2E5
Auto restart
••
S-160ME1R5A S-160ME1R5A
•• ••
S-106MK2E5A S-106MK2E5A
S-106MU2E5A S-106MU2E5A
S-140MU2E5A S-140MU2E5A
•• ••
S-160MU2E5A S-160MU2E5A
•• •• •• •• •• •• S-106MT2E5A S-106MT2E5A
•• ••
S-140MT2E5A S-140MT2E5A
•• Automatic fan operation
Mild dry
Intelligent auto flap control
Automatic restart function for power failure
Air swing
Mild dry (High Static Ducted)
DC motor
self-diagnosing Auto fan
Mild dry
Auto restart
self-diagnosing Auto fan
Mild dry
Auto flap
DC motor Auto restart
Air swing
DC motor
self-diagnosing Auto fan
Mild dry
Auto flap
Auto restart
Drain pump
DC motor
self-diagnosing Auto fan
Mild dry
Auto flap
Auto restart
Drain pump
DC motor
self-diagnosing Auto fan
Mild dry
Auto flap
Auto restart
Drain pump
DC motor Air swing
DC motor Air swing
Air swing
self-diagnosing Auto fan
Mild dry
Auto flap
Auto restart
Drain pump
DC motor
Mild dry
Auto flap
DC motor Air swing
self-diagnosing Auto fan
DC motor Auto restart
••
Self-diagnosing function
Mild dry
DC motor Auto restart
High Fresh Air
Drain pump
Air swing
DC motor
self-diagnosing Auto fan
Mild dry
Auto restart
self-diagnosing Auto fan
Mild dry
Auto restart
Built-in drain pump
DC motor
DC motor
31
BRO-AC-HOME1920
Authorised Dealer