RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2014 / 2015
EVERY BUILDING MATTERS
Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.
PAC-Oceania-2014-15
PAC_2014_15_1.indd 1-1
EVERY BUILDING MATTERS 2014/09/08 15:49
Panasonic Air Conditioning Designed To Care For Your Projects. With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic is unquestionably one of the leaders in the air conditioning sector. The company is also a world leader in innovation as it has filed more than 91,539 patents to improve its customers’ lives. Moreover, Panasonic is determined to remain at the forefront of its market. In all, the company has produced more than 200 million compressors and its products, particularly residential air conditioners, now hold the No. 1 market share in Japan and other major countries in Asia. You can be assured of the extremely high quality of Panasonic’s air conditioners. This wish to excel has made Panasonic the international leader in air conditioning solutions. The company’s industrial capacity and firm commitment to the environment has enabled it to open new avenues of research and to develop innovative technologies which enhance its customers’ way of life. Panasonic offers a range of turnkey air conditioning solutions for homes, medium-sized buildings such as offices and restaurants. These offer maximum effectiveness, comply with the strictest environmental standards and meet the most avant-garde construction requirements of our time. At Panasonic we know what a great responsibility it is to install cooling and heating systems. Because offering you the best solutions in cooling and heating matters.
EVERY BUILDING MATTERS
WHAT’S NEW 2014 New Feature 1
Using sensors and precise control programs, ECONAVI analyzes room conditions and adjusts cooling and heating power to reduce wasted electricity.
CONTENTS Introduction
02 - 03
2014 New Features
04 - 09
Product Range
10 - 11
Outdoor Units
12 - 17
2014 New Feature 2
Hi-Spec Wired Remote Controller Features a large LCD and touch keys for easy operation, and a range of energy-saving functions.
Indoor Unit
Ducted type
18 - 21
4-Way cassette type
22 - 25
Ceiling mounted type
26 - 29
Controllers 2
PAC_2014_15_1.indd 2-3
30 - 47 3
2014/09/08 15:49
2014 New Feature 1
ECONAVI reduces inefficient air conditioning Providing outstanding energy-saving performance, Panasonic's package air conditioners can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of a room. When unnecessary heating or cooling is detected, indoor units are individually controlled to match room conditions for energy-saving operation.
Detection of the level of activity enables optimum power saving.
Sensors are remotely located to maximize the energy-saving effect
Presence or absence of people at their tables and the level of activity in the room are detected in real time. Set temperature is automatically adjusted to optimize the power consumption.
Pillars, walls, cabinets and other fittings obstruct the sensors, reducing the area of detection and lowering the energy-saving effect. Taking into consideration blind spots, Panasonic enables the optimum layout for sensors in any office.
Case study at coffee shop
1m 3m 5m 7m
Wide detection area -60°
In the morning Reduced cooling when there are fewer people
4way Cassette
-40° -20°
A Automatic Thermo Off depending on conditions at tthe end of the day* *Depending on conditions, the setting can change to Switch Off After 3 Hours, Thermo Off or Temperature Shift.
max.
28% energy-saving effect was verified
Energy-saving effect tested and verified. That's why Panasonic's ECONAVI is recommended.
7m
Dead Zone
At night A
With the set temperature increased by 2°C during cooling,
Wide 120˚
Approx 1m
Celling
Panasonic enables use with various types of indoor units
20°
Detection area
Thorough cooling when there is a high level of activity
Mid static Duct
0°
2.5m
In the afternoon
ECONAVI Sensor CZ-CENSC1
60° 40°
A sensor is remotely set to maximize the detection area. Installation flexibility ready for indoor unit replacement and layout changes.
Test method
Test conditions
*Tested with a uniform level of human activity and with doors opened and closed a uniform number of times. *At 24 to 28°C, cumulative power consumption over 3 hours measured at each set temperature and compared. Equivalent energy-saving effect during ECONAVI Save C temperature shift calculated. cooling with a 22°C
*Panasonic test room (29m2) Indoor unit: S-100PU1 (Single 4-way Cassette 4.0HP) Outdoor unit: U-100PE1 (Single DLX 4.0HP) * Cooling operation, set temperature of 24 to 28°C, Hi airflow setting
CASE 1
CASE 2
In a coffee shop, for example, power is reduced to match the number of customers in each area.
In an apartment, for example, energy saving to match the number of people present is provided and operation is automatically turned off if it has been forgotten.
Gentle cooling in areas of low activity
WALK-IN CLOSET MASTER A ER BEDROOM BATH
BALCONY
SEATING AREA
BEDROOM
COUNTER TABLE KITCHEN
: :
ENTRANCE
Indoor units (3) Sensors (3) Thorough cooling in areas of high activity
BALCONY
Gentle cooling in areas of low activity
LIVING
Thorough cooling in areas of high activity
4
PAC_2014_15_1.indd 4-5
APARTMENT
Indoor units (3) : Grilles (3) Sensors (3) :
ENTRANCE
:
5
2014/09/08 15:50
2014 New Feature 2
High-spec Wired Remote Controller
Easy-to-use, with multiple functions that contribute to energy saving.
Energy consumption display and Log function Energy Consumption Monitoring Display Graphs of daily, weekly and annual power consumption are displayed. A visual representation of power consumption lets you confirm the energy-saving effect and quickly detect energy-wasting operation. This helps to further improve energy saving.
Day
Week
Month
Multiple control settings to meet a wide range of air conditioning needs Temperature Auto Return
Actual size
1
Large 3.5" Full-dot LCD with White LED Backlight Characters and icons are clearly displayed for improved visibility. The display is also large enough to provide a wide range of information for easy confirmation of operation conditions.
6
PAC_2014_15_1.indd 6-7
2
Even if you change the temperature setting, after a set time it automatically returns to the original temperature setting. You can set temperature auto return time in 10-minute intervals within a period of 4 hours.
Stylish, Easy-to-use Touch Key Design The elegant, flat design features large touch keys in a simple layout enabling easy, intuitive operation.
Temperature Setting Range Limitation You can set the upper and lower temperature limits. Doing this helps reduce power consumption due to over cooling or heating. Setting is possible in the Cooling, Heating and Dry modes.
Auto Shutoff Air conditioning automatically stops after a set time, so you don’t have to worry about forgetting to switch the unit off. Even if you manually switch the unit back on after it has stopped, it automatically switches off again after the set time.
7
2014/09/08 15:50
Hi-Spec Remote Controller
Function List
Wide range of controls for extra convenience Individual Louver Control (Lock Individual Flap only for 4-way cassette U1 type)
Control Item
One of the 4-directional outlets can be selected and locked to provide efficient air distribution that matches the indoor unit layout. Indoor units can be set individually.
Controllability
Basic instructions FLAP Individual louver control (Lock individual flap for 4-way cassette) ON/ OFF timer
Weekly Timer
This lets you specify 8 Start/Stop times and temperature presets for each day of the week.
Weekly timer
Menu items
Filter information Outing function Quiet operation mode Power consumption monitor Energy saving
Service Contact Address
Initial settings
Once you have register service contact details, they are automatically displayed if a problem with the air conditioner occurs. This helps you quickly deal with the situation.
Ventilation Temperature auto return Temperature setting range
Energy Saving
Auto shutoff Schedule peak cut Repeat off timer ECONAVI on/ off
Convenient Controls Operation Lock To prevent operation by anyone other than the supervisor, operation keys can be locked. This prevents anyone changing or tampering with temperature settings, airflow rate, airflow direction and other settings.
Filter Information
PAC_2014_15_1.indd 8-9
Maintenance Function Display of outdoor malfunction data, service contact details, filter cleaning remaining time and other data enables at-aglace verification of maintenance information with the remote controller.
Filter information is indicated for cleaning after a set time of operation has passed. The number of hours can be adjusted.
Repeat OFF Timer
Quiet Operation Mode
Setting Information Lists
There’s a Quiet mode that reduces the outdoor unit’s operating noise. The mode can be switched On/Off and the Start/End times can be set with the remote controller.
8
Outdoor unit error data Service Contact address RC setting mode
Maintenance Function
Test Run Sensor Information Service check Simple/ Detailed Settings Auto address
You can set the unit to switch off after a desired period of time.
Information concerning current settings is displayed in the remote controller’s LCD for easy confirmation.
9
2014/09/08 15:50
Panasonic provides ideal solutions for large-capacity air conditioning needs.
CAPACITY (HP)
2.5 HP
Ducted
3.0 HP
4.0 HP
5.0 HP
6.0 HP
S-60PE1R5A
S-71PE1R5A
S-100PE1R5A
S-125PE1R5A
S-140PE1R5A
S-60PU1R5A
S-71PU1R5A
S-100PU1R5A
S-125PU1R5A
S-140PU1R5A
S-100PT2R5A
S-125PT2R5A
S-140PT2R5A
High Static Pressure Model Page 18-21
Indoor Unit
ECONAVI ready
4-Way Cassette * Panel is provided as an option (CZ-KPU21)
Page 22-25
ECONAVI ready
S-60PT2R5A
Ceiling Mounted
S-71PT2R5A
Page 26-29
ECONAVI ready
CAPACITY (HP)
Outdoor Unit
Page12-17
EVERY BUILDING MATTERS 10
PAC_2014_15_1.indd 10-11
2.5 HP
U-60PE1R5A
3.0 HP
U-71PE1R5A
4.0 HP
U-100PE1R5A U-100PE1R8A*
5.0 HP
U-125PE1R5A U-125PE1R8A*
6.0 HP
U-140PE1R5A U-140PE1R8A*
(*3-phase)
11
2014/09/08 15:50
Outdoor Unit
Outdoor Unit DC Inverter can attain both comfort and energy-saving operation
• Obtaining All Necessary Safety Approvals to ensure quality and safety • Top-class EER:4.20 / COP:4.31 (Cassette type:4HP) • Compiled Demand Response(DRED) • Cooling operation is possible when outdoor temperature as high as 46°C • DC inverter technology combined with R410A for excellent efficiency
• Piping length:75m (Total piping length:75m) • Cooling operation is possible when outdoor temperature as low as -15°C • Heating operation is possible when outdoor temperature as low as -20°C • One ampere starting current • Auto restart from outdoor unit
Product Quality and Safety All Panasonic air conditioners undergo strict quality and safety tests before sale. This rigorous process includes obtaining All Necessary Safety Approvals, to ensure that all air conditioners we sell are not only built to the highest market standards, but are also completely safe.
Energy-saving concept The use of energy saving design for the structure of fans, fan motors, compressors and heat exchangers resulted in high COP value which ranked as one the top class in the industry. In addition, use of highly efficient R410A refrigerant reduces CO2 emission and lowers operating costs.
5
4
3
2
Compressor
Large-capacity inverter compressor has been adopted. The inverter compressor is superior in performance with improved partial-load capacity.
Printed Circuit Board (S-LINK)
The number of PCB was reduced from 3 into 2 pieces to improve maintenance work.
Compact &
1 High Efficient
2
3 DC fan motor
Checking load and outside temperature, the DC motor is controlled for optimum air volume.
New Large 4 Diagonal (520mm) Air Flow Fan
The newly designed fan has been realized to inhibit air turbulence and to increase efficiency. As fan diameter has been increased to 520mm, the air volume has been increased whilst maintaining a low sound level.
High-Efficiency Heat Exchanger
The heat exchanger size and the copper tube sizes in the heat exchanger has been redesigned to increase efficiency.
1
5
12
PAC_2014_15_1.indd 12-13
13
2014/09/08 15:50
Outdoor Unit
Outdoor Unit Improved Energy Saving
Demand Response Compliant
The operation efficiency has been improved using highly efficient R410A refrigerant, new DC inverter compressor, new DC motor and new design of heat exchanger.
Panasonic air conditioners are equipped with a Demand Response Enabling Device (DRED) which complies to both AS 4755 and AS 3823. Panasonic continues to design and develop products that are tailored to local needs and requirements. This ensures that Panasonic products that you are installing today are compliant with the demand response standards are likely to be implemented shortly.
Cooling (Ducted) Cooling
Heating (Ducted) Heating
3.7
Previous
3.6
PE1
Previous
3.6
3.5
3.5
3.36
3.4 3.3
3.24
3.23
3.4
3.26
3.01
3.0
3.15
3.42
3.45
PE1
3.52
3.52 3.32
3.37
3.34
3.2 3.1
3.01
3.01
3.41 3.41
3.48
3.3
3.21
3.2 3.1
3.7
3.0
2.9
The Equipment Energy Efficiency (E3) program has been supporting the development of Demand Response Enabling Device (DRED) standards for airconditioners which should comply with AS 4755. DRED functionality is not compulsory today, however, this capability will be required for all installations in the very near future
DRM1 DRM2 DRM3
2.7
2.8
Outdoor unit
2.7
2.5 HP
3.0 HP
4.0 HP
5.0 HP
6.0 HP
2.5 HP
3.0 HP
4.0 HP
5.0 HP
6.0 HP
Wide Operating Range
Demand control terminal is available to control 0-50-75-100% of capacities.
Compact and Lightweight
• Cooling operation is possible when outdoor temperature as low as -15°C • Cooling operation is possible when outdoor temperature as high as 46°C • Heating operation is possible when outdoor temperature as low as -20°C The remote controller temperature setting offers a range from 16°C to 30°C. 12.1 kW - 15.5 kW
Demand controller
Terminal block
2.9
2.77
2.8
C
Lightweight
The weight is only 98kg. Hence it is easy to carry, easy to install.
98kg
Cooling: -15°C DB to 46°C DB Heating: -20°C DB to 24°C DB
Compact & Flexible-design The slim and lightweight design can be installed in various places.
Increased Piping Length for Greater Design Flexibility Single Split
Adaptable to various building types and sizes Max. piping length : 75m (4HP, 5HP, 6HP), 50m (2.5HP, 3HP) Height difference 30m*1
FS Multi
Quiet Mode 5dB can be reduced by setting. External input signal is also available.
*1 15 m if the outdoor unit is below the indoor unit.
Max. piping length: 75m (4,5,6HP) 50m (2.5,3HP) 14
PAC_2014_15_1.indd 14-15
15
2014/09/08 15:50
Outdoor Unit
Outdoor Unit Dimensions (4.0 HP - 6.0 HP) Unit:mm
4
26
8
35
16
PAC_2014_15_1.indd 16-17
Mounting hole, anchor bolt:M10 Refrigerant piping (liquid pipe),flared connection (ø9.52) Refrigerant piping (gas pipe),flared connection (ø15.88) Refrigerant piping hole Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35)
40
5
3
Air intake
Air discharge
7
51
90
Handle
View B
5
6
7
8
4
26
60 35 86
39
48
57.5
8 60 84.5 109.5
35
4
47
6
8
7
51
7
81
64
522
39 42
120
4
490
6 120
16
5
unit: mm 1) 2) 3) 4) 5) 6) 7) 8)
2
35
6
61
Refrigerant piping end connection
68.5
120
81 84.5 109.5
173
39
462
48 120
120
430
39
8
48
81
7
60
4
B
31.5
Hole (Bottom)
47
81
996
6
7 8
340
16
Air intake
Air discharge
41
B
120
5
62
1416
68.5
Anchor hole
Enlarged view A
Refrigerant piping end connection
6
5
2-18x13 Anchor hole
57.5
5
60 35 86
Air discharge
Enlarged view A
340
Hole (Bottom)
3
Air intake
48
41
61
Space for piping, wiring and maintenance
Space for piping,wiring and maintenance
173
31.5
Air intake
75.5
75.5
62
Handle
13
200 or more
76
340 41
380.5
2-18x13 Anchor hole
2
940
1
76
1
Air discharge
13
A
Anchor hole
40
940
Air intake
500 or more
2-U shaped hole 100 or more
Space for piping,wiring and maintenance
18
41
340
A
Space for piping, wiring and maintenance
150
380.5
200 or more Air intake
620
18
2-U shaped hole
170
300
150
35
620
100 or more
170
500 or more
300
Dimensions (2.5 HP - 3.0 HP)
4
42
64 90
View B unit: mm
1) 2) 3) 4) 5) 6) 7) 8)
Mounting hole, anchor bolt:M10 Refrigerant piping(liquid pipe),flared connection (ø9.52) Refrigerant piping(gas pipe),flared connection (ø15.88) Refrigerant piping hole Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35)
17
2014/09/08 15:50
Indoor Unit / Ducted
Indoor Unit
Ducted Hidden in the ceiling to provide an ideal match for luxury residences and light commercial buildings.
ECONAVI ready
S-60PE1R5A S-71PE1R5A S-100PE1R5A
S-125PE1R5A S-140PE1R5A
Compact Body Size
Cold Drafts Reduction at Heating
Hidden in the ceiling, ideal when interior decor is an important consideration such as in residences with many rooms and light commercial buildings.
• Accurate temperature measurement by E1/E2 sensor to reduce cold drafts at heating.
1,100 mm
1,100
700
mm
mm
700 mm
Air intake sensor E2 sensor
430
E1 sensor
mm
290 mm (60PE) 360 mm (71PE, 100PE)
60PE, 71PE, 100PE
125PE, 140PE
System Example An inspection port (450 mm x 450 mm or more) is required at the control-box side of the indoor unit body.
Rectangle duct
Inspection port (450 x 450 mm or more)
18
PAC_2014_15_1.indd 18-19
Canvas duct
Intake grille
19
2014/09/08 15:51
Indoor Unit / Ducted
Indoor Unit
Ducted Dimensions
Optional Controller Dimensions: mm
model
A
B
C
D
S-60PE1R5A
130
33.1
290
118
S-71PE1R5A S-100PE1R5A
195
35.7
360
50
S-125PE1R5A S-140PE1R5A
260
38.2
430
121.5
2.Gas side (O.D.ø15.88 FLARE) 2.Gas side (O.D.ø15.88 FLARE)
High-spec wired remote controller CZ-RTC3
Timer remote controller CZ-RTC2
Simplified remote controller CZ-RE2C2
3.Drain pipe size (O.D.ø32)
3.Drain pipe size (O.D.ø32) 1.Liquid side (O.D.ø9.52 FLARE)
ECONAVI sensor CZ-CENSC1
1.Liquid side (O.D.ø9.52 FLARE)
Wireless remote controller CZ-RWSK2 + CZ-RWSC3
Capacity Model Name
2.5HP
3HP
4HP
Indoor Unit
S-60PE1R5A
S-71PE1R5A
S-100PE1R5A
S-100PE1R5A
S-125PE1R5A
S-125PE1R5A
S-140PE1R5A
S-140PE1R5A
Outdoor Unit
U-60PE1R5A
U-71PE1R5A
U-100PE1R5A
U-100PE1R8A
U-125PE1R5A
U-125PE1R8A
U-140PE1R5A
U-140PE1R8A 3 Phase/ 50Hz
Power source
Cooling capacity : Heating capacity
5HP
6HP
Phase/Hz
1 Phase/ 50Hz
1 Phase/ 50Hz
1 Phase/ 50Hz
3 Phase/ 50Hz
1 Phase/ 50Hz
3 Phase/ 50Hz
1 Phase/ 50Hz
V
230V | 240V
230V | 240V
230V | 240V
400V | 415V
230V | 240V
400V | 415V
230V | 240V
400V | 415V
kW
6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0)
7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0)
10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)
10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)
12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)
12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)
14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0)
14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0)
BTU/h
20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300)
24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700)
34,100 (11,300 - 42,700) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 38,200 (14,000 - 47,800)
42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)
42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)
47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400)
47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400)
W/W
3.24 : 3.41
3.23 : 3.48
3.36 : 3.52
3.36 : 3.52
3.21 : 3.37
3.21 : 3.37
3.15 : 3.52
3.15 : 3.52
Cooling : Heating
kW
1.85 : 2.05
2.20 : 2.30
2.98 : 3.18
2.98 : 3.18
3.90 : 4.16
3.90 : 4.16
4.45 : 4.55
4.45 : 4.55
Current
Cooling : Heating
A
0.85 : 0.85 | 0.86 : 0.86
1.24 : 1.24 | 1.25 : 1.25
1.72 : 1.72 | 1.74 : 1.74
1.72 : 1.72 | 1.74 : 1.74
1.82 : 1.82 | 1.84 : 1.84
1.82 : 1.82 | 1.84 : 1.84
2.62 : 2.62 | 2.70 : 2.70
2.62 : 2.62 | 2.70 : 2.70
Dimensions
H×W×D
mm
290×1,100 (+100)×700
360×1,100 (+100)×700
360×1,100 (+100)×700
360×1,100 (+100)×700
430×1,100 (+100)×700
430×1,100 (+100)×700
430×1,100 (+100)×700
430×1,100 (+100)×700
kg
35
42
44
44
48
48
53
53
L/s
366 : 366
500 : 500
666 : 666
666 : 666
833 : 833
833 : 833
1,000 : 1,000
1,000 : 1,000
Pa
70 (Max.100)
100 (Max.150)
100 (Max.150)
100 (Max.150)
100 (Max.150)
100 (Max.150)
100 (Max.150)
100 (Max.150)
EER : COP Total power input Indoor Unit
Net weight Air volume
Cooling : Heating
External static pressure Sound pressure level (H/M/L)
Cooling : Heating
dB(A)
43 / 41 / 40 : 43 / 41 / 40 45 / 44 / 43 : 45 / 43 / 44 48 / 46 / 44 : 48 / 46 / 44 48 / 46 / 44 : 48 / 46 / 44
49 / 47 / 45 : 49 / 47 / 45 49 / 47 / 45 : 49 / 47 / 45 51 / 49 / 47 : 51 / 49 / 47 51 / 49 / 47 : 51 / 49 / 47
Sound power level (H/M/L)
Cooling : Heating
dB(A)
60 / 58 / 57 : 60 / 58 / 57 62 / 61 / 60 : 62 / 61 / 60 70 / 68 / 66 : 70 / 68 / 66 70 / 68 / 66 : 70 / 68 / 66
71 / 69 / 67 : 71 / 69 / 67 71 / 69 / 67 : 71 / 69 / 67 73 / 71 / 69 : 73 / 71 / 69 73 / 71 / 69 : 73 / 71 / 69
Number of fan speed Drain pipe size
3
3
3
3
3
3
3
3
mm
VP-25
VP-25
VP-25
VP-25
VP-25
VP-25
VP-25
VP-25
Outdoor Unit Current
Cooling : Heating
A
7.85 : 8.80 | 7.65 : 8.60
9.10 : 9.30 | 8.80 : 9.00
11.8 : 12.7 | 11.40 : 12.3
3.95 : 4.25 | 3.80 : 4.10
16.0 : 17.2 | 15.4 : 16.6
5.30 : 5.70 | 5.10 : 5.50
17.8 : 18.1 | 17.2 : 17.5
5.80 : 5.95 | 5.55 : 5.70
Dimensions
H×W×D
mm
996 × 940 × 340
996 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
Net weight
20
PAC_2014_15_1.indd 20-21
kg
68
69
98
98
98
98
98
98
Air volume
Cooling : Heating
L/s
1,000 : 1,000
1,000 : 1,000
1,833 : 1,583
1,833 : 1,583
2,166 : 1,833
2,166 : 1,833
2,250 : 2,000
2,250 : 2,000
Sound pressure level (Silent mode)
Cooling : Heating
dB(A)
48 (46) : 50 (48)
48 (46) : 50 (48)
52 (50) : 52 (50)
52 (50) : 52 (50)
53 (51) : 53 (51)
53 (51) : 53 (51)
54 (52) : 55 (53)
54 (52) : 55 (53)
Sound power level (Silent mode)
Cooling : Heating
dB(A)
65 (63) : 67 (65)
65 (63) : 67 (65)
69 (67) : 69 (67)
69 (67) : 69 (67)
70 (68) : 70 (68)
70 (68) : 70 (68)
71 (69) : 71 (69)
71 (69) : 71 (69)
Piping connections
Liquid/Gas
m
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Pipe length
min. - max.
m
5 - 50
5 - 50
5 - 75
5 - 75
5 - 75
5 - 75
5 - 75
5 - 75
Elevation difference (OU located lower, OU located higher)
m
15, 30
15, 30
15, 30
15, 30
15, 30
15, 30
15, 30
15, 30
Maximum chargeless length
m
30
30
30
30
30
30
30
30
Refrigerant at shipping, Additional gas amount
g
R410A 2,000, 50 (g/m)
R410A 2,350, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
Operation ranges
˚C
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
Cooling : Heating
21
2014/09/08 15:51
Indoor Unit / 4-Way Cassette
Indoor Unit
4-WAY Cassette Provide a neat fit in the ceiling to match modern decors, uniform cooling throughout the room, plus easy installation.
Self-diagnosing Function
Automatic Fan Operation
Mild dry
Intelligent Auto Swing
Automatic Restart Function
Auto Swing (Auto Flap Control)
AIR INTAKE CHAMBER 2
ECONAVI ready 1
Air intake box CZ-BCU2 for main unit.
2
Air intake box CZ-ATU2* for Air intake plenum.
CZ-KPU21
* When using Air intake box (CZ-ATU2), Air intake plenum (CZ-FDU2) required.
Built-in Drain Pump
Technical focus • Compact design • Reduced sound levels (from previous models) • DC fan motor for increased efficiency • Powerful drain pump gives 850 mm lift
PANEL
1
High-Ceiling Installation (Up to 5 m for 100PU and higher models) • Lightweight design • Fresh air knockout • Branch duct connection • Optional air-intake plenum CZ-FDU2
The units can be installed in rooms with high ceilings, where they provide ample floor-level heating in the winter. (See ceiling height guidelines below.) High Ceiling
(Factory settings)
3.6m
3.0m
New model
Wide & Comfortable Airflow A proprietary design features wide-angle discharge outlets and flaps that are larger in the middle, featuring a shape that was selected based on numerical mechanics and testing of actual prototype units. Air coming out of the center of the discharge outlets travels farther. From the sides of each outlet, where the openings are larger, airflow spreads out to reach the corners of the room. Air is discharged across a wide area from the four sides of the unit. The curves on the room temperature distribution graph expand gently out through 360° in a circle centered on the indoor unit.
Temperature distribution by thermograph (cooling operation)
Comfort/Quiet Ample airflow: 36 m3/min
22
PAC_2014_15_1.indd 22-23
100PU, 125PU, 140PU
Industry’s highest in the 140PU class. Industry’s top-class
4-way discharge
Capacity
5m
4.7m
4.5m
100PU-140PU
high ceiling settings2
3-way discharge
2-way discharge
with the optional air-blocking materials
with the optional air-blocking materials
Ceiling height guidelines 360° Wide
*1 settings 4-way discharge
3-way discharge (optional
2-way
air-blocking materials)
discharge (optional air-blocking materials) *2
3.6
3.8
4.2
4.5
4.7
5.0
Factory settings 1
High ceiling setting 1
High ceiling setting 2
60PU-71PU
3.0
3.3
100PU, 125PU, 140PU
3.6
3.9
Indoor unit
1m
Simulation conditions: P140 4-way ceiling-mounted cassette type in cooling mode / Floor area of 225 m2 / Ceiling height of 3 m
60PU, 71PU
Capacity
*1 When using the unit in a configuration other than the factory settings, it is necessary to make settings on site to increase airflow. *2 Use air-blocking materials (CZ-CFU2) to completely block two discharge outlets for 2-way airflow.
23
2014/09/08 15:51
Indoor Unit / 4-Way Cassette
Indoor Unit
4-way Cassette
13 ø1
Up to
850 mm
6
B 30
2
* Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 30 mm or more (18 mm or more from the lower surface of the body) as shown in the figure. When the suspension bolt length is long, it hits the ceiling panel and installation is not possible.
3 HP
4 HP
S-71PU1R5A
S-100PU1R5A
S-100PU1R5A
S-125PU1R5A
S-125PU1R5 A
S-140PU1R5A
S-140PU1R5A
Outdoor Unit
U-60PE1R5A
U-71PE1R5A
U-100PE1R5A
U-100PE1R8A
U-125PE1R5A
U-125PE1R8A
U-140PE1R5A
U-140PE1R8A
5 HP
6 HP
CZ-KPU21
CZ-KPU21
CZ-KPU21
CZ-KPU21
CZ-KPU21
CZ-KPU21
CZ-KPU21
CZ-KPU21
Phase/Hz
1 phase, 50Hz
1 phase, 50Hz
1 phase, 50Hz
3 phase, 50Hz
1 phase, 50Hz
3 phase, 50Hz
1 phase, 50Hz
3 phase, 50Hz
V
230V | 240V
230V | 240V
230V | 240V
400V | 415V
230V | 240V
400V | 415V
230V | 240V
400V | 415V
kW
6.0 (2.5 - 8.0) 7.0 (2.0 - 8.5)
7.1 (2.5 - 8.2) 8.0 (2.0 - 9.0)
10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)
10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)
12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)
12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)
14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0)
14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0)
BTU/h
20,500 (8,500 - 27,300) 23,900 (6,800 - 29,000)
24,200 (8,500 - 28,000) 27,300 (6,800 - 30,700)
34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800)
34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800)
42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)
42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)
47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400)
47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400)
Cooling : Heating
W/W
4.05 : 3.87
3.94 : 4.00
4.20 : 4.31
4.20 : 4.31
3.60 : 4.00
3.60 : 4.00
3.25 : 3.70
3.25 : 3.70
kW
1.48 : 1.81
1.80 : 2.00
2.38 : 2.60
2.38 : 2.60
3.47 : 3.50
3.47 : 3.50
4.31 : 4.33
4.31 : 4.33
Cooling : Heating
A
0.31 : 0.30 | 0.30 : 0.29
0.33 : 0.32 | 0.32 : 0.31
0.71 : 0.65 | 0.71 : 0.64
0.71 : 0.65 | 0.71 : 0.64
0.76 : 0.73 | 0.73 : 0.73
0.76 : 0.73 | 0.73 : 0.73
0.89 : 0.80 | 0.87 : 0.79
0.89 : 0.80 | 0.87 : 0.79
Indoor
mm
256 × 840 × 840
256 × 840 × 840
319 × 840 × 840
319 × 840 × 840
319 × 840 × 840
319 × 840 × 840
319 × 840 × 840
319 × 840 × 840
Optional Controller
ECONAVI sensor CZ-CENSC1
High-spec wired remote controller CZ-RTC3
Timer remote controller CZ-RTC2
Wireless remote controller CZ-RWSU2
Wireless remote controller CZ-RWSK2 + CZ-RWSC3
Simplified remote controller CZ-RE2C2
Indoor Unit
Panel
mm
33.5 x 950 x 950
33.5 x 950 x 950
33.5 x 950 x 950
33.5 x 950 x 950
33.5 x 950 x 950
33.5 x 950 x 950
33.5 x 950 x 950
33.5 x 950 x 950
Net weight
Indoor
kg
24
24
27
27
27
27
27
27
Panel
kg
4
4
4
4
4
4
4
4
Air volume
Cooling : Heating
L/s
350 : 350
366 : 366
550 : 550
550 : 550
583 : 583
583 : 583
600 : 600
600 : 600
Sound pressure level (H/M/L)
Cooling : Heating
dB(A)
36 / 31 / 28 : 36 / 31 / 28 37 / 31 / 28 : 37 / 31 / 28 44 / 38 / 32 : 44 / 38 / 32 44 / 38 / 32 : 44 / 38 / 32
45 / 39 / 33 : 45 / 39 / 33 45 / 39 / 33 : 45 / 39 / 33 46 / 40 / 34 : 46 / 40 / 34 46 / 40 / 34 : 46 / 40 / 34
Sound power level (H/M/L)
Cooling : Heating
dB(A)
53 / 48 / 45 : 53 / 48 / 45 54 / 48 / 45 : 54 / 48 / 45 62 / 55 / 49 : 62 / 55 / 49 62 / 55 / 49 : 62 / 55 / 49
63 / 56 / 50 : 63 / 56 / 50 63 / 56 / 50 : 63 / 56 / 50 64 / 57 / 51 : 64 / 57 / 51 64 / 57 / 51 : 64 / 57 / 51
3
3
3
3
3
3
3
3
mm
VP-25
VP-25
VP-25
VP-25
VP-25
VP-25
VP-25
VP-25
A
6.90 : 8.20 | 6.70 : 7.95
8.10 : 9.00 | 7.90 : 8.70
10.3 : 11.4 | 9.90 : 11.0
3.50 : 3.85 | 3.40 : 3.75
15.3 : 15.4 | 14.8 : 14.9
5.15 : 5.20 | 5.00 : 5.05
19.0 : 19.2 | 18.4 : 18.6
6.45 : 6.50 | 6.20 : 6.25
mm
996 × 940 × 340
996 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
kg
68
69
98
98
98
98
98
98
Number of fan speed
160 118 18
Air intake duct connection hole (ø100)
2.5 HP
Drain pipe size
167 130 95
130
2
Dimensions: mm
Cooling : Heating
H×W×D
7
Drain up
EER : COP
Dimensions
9
1
80
Total power input Current
160
2
S-60PU1R5A
Cooling capacity Heating capacity
82
2
Indoor Unit PANEL
50
515
le 4 -ø3 Burring ho
The drain height can be increased by approximately 350 mm over the conventional value by using a high-lift drain pump, and long horizontal piping is possible.
271
950 514 Less than 670
115
Drain Pump of about 850 mm from the ceiling surface
115
Air discharge duct connection hole (ø150)
Up to 300 mm
X view
4
160
7
Less than 300
Less than 850
ø3 hole 4 Burring
256 mm
480
7
A
180 B
145
80
A Drain Height of Approx. 850 mm from the Ceiling Surface
Less than 35 7
62 ø1
Capacity
2
95
Less than 35
Only
3
100PU-140PU 319 187
840
167
Protrusion of 33.5 mm
A lightweight unit at 24 kg, the unit is also very slim with a height of only 256 mm, making installation possible even in narrow ceilings. * For 2.5HP/3.0HP
Power source
345
5 840 480
Lighter and Slimmer, Easier Installation
Model Name
8
745 (Suspension bolt pitch) 860~910 (Ceiling opening dimension)
The square panel integrates seamlessly with the ceiling. Discharge outlets close when the unit is stopped.
786 (Suspension bolt pitch)
*1: Air inlet kit is necessary. Filter size: 520 x 520 x 16
60PU-71PU 256 124
A B
(411)
One of the industry’s thinnest panels
X 860~910 (Ceiling opening dimension)
Air intake grill Air discharge outlet Refrigerant piping (liquid pipes) : ø9.52 (flared) Refrigerant piping (gas pipes) : ø15.88 (flared) Drain outlet VP25(outer ø32) Power supply port Discharge duct (ø150) Suspension bolt hole (4-12x30 slot) Fresh air intake duct connection port (ø100)*1
50
Low-Profile 33.5 mm Panel
1 2 3 4 5 6 7 8 9
42 121 33.5
The flap can be removed easily for washing with water.
Dimensions
A suction grill enables to make 90-degree turns.
950
It is easy to remove a washable flap by hand.
421
Easy Maintenance and Cleaning
Outdoor Unit Current Dimensions
Cooling : Heating H×W×D
Net weight Air volume
Cooling : Heating
L/s
1,000 : 1,000
1,000 : 1,000
1,833 : 1,583
1,833 : 1,583
2,166 : 1,833
2,166 : 1,833
2,250 : 2,000
2,250 : 2,000
Sound pressure level (Silent mode)
Cooling : Heating
dB(A)
48 (46) : 50 (48)
48 (46) : 50 (48)
52 (50) : 52 (50)
52 (50) : 52 (50)
53 (51) : 53 (51)
53 (51) : 53 (51)
54 (52) : 55 (53)
54 (52) : 55 (53)
Sound power level (Silent mode)
Cooling : Heating
Piping connections Pipe length
min. - max.
Elevation difference (OU located lower, OU located higher)
24
PAC_2014_15_1.indd 24-25
dB(A)
65 (63) : 67 (65)
65 (63) : 67 (65)
69 (67) : 69 (67)
69 (67) : 69 (67)
70 (68) : 70 (68)
70 (68) : 70 (68)
71 (69) : 71 (69)
71 (69) : 71 (69)
m
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
m
5 - 50
5 - 50
5 - 75
5 - 75
5 - 75
5 - 75
5 - 75
5 - 75
m
15, 30
15, 30
15, 30
15, 30
15, 30
15, 30
15, 30
15, 30
Maximum chargeless length
m
30
30
30
30
30
30
30
30
Refrigerant at shipping, Additional gas amount
g
R410A 2,000, 50 (g/m)
R410A 2,350, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
Operation ranges
˚C
-15 - 46 : -20 - 24
-15 - 46 : -20 - 24
-15 - 46 : -20 - 24
-15 - 46 : -20 - 24
-15 - 46 : -20 - 24
-15 - 46 : -20 - 24
-15 - 46 : -20 - 24
-15 - 46 : -20 - 24
Cooling : Heating
25
2014/09/08 15:51
Indoor Unit / Ceiling Mounted
Indoor Unit
Ceiling Mounted Providing outstanding energy-saving performance and comfortable, long-distance air flow distribution, it’s recommended for stores and schools.
ECONAVI ready S-60PT2R5A S-71PT2R5A
S-100PT2R5A S-125PT2R5A S-140PT2R5A
Compact Looking, Stylish, One-Motion Design
Comfortable, Long-Distance Air Flow Distribution
With its streamlined, one-motion form, the unit looks thin and compact when installed for a neat appearance in any room. When not operating, the louver closes to provide an elegant look while keeping the unit clean.
The shape of the outlet has been optimized to provide long-distance air flow distribution. Even in deep spaces, air flow reaches every corner for exceptionally comfortable air conditioning.
Energy-Saving Technology Delivering Top-Class Efficiency
Ceiling height
4.3m*
Top Class Energy Saving
Air flow distance
13m*
Optimization of the shape of the casing and fan assures bigger air flow and higher efficiency. Energy-saving performance is top class in the industry. New DC fan motor
* Results are based on specific testing conditions
Large Diagonal Air Flow Fan High Ceiling Setting
DC motor 26
PAC_2014_15_1.indd 26-27
Air flow distance
*Setting by remote control
112
140
160
4.3m
12m
13m
13m
Fan diameter
f 147.5
27
2014/09/08 15:51
Indoor Unit / Ceiling Mounted
Indoor Unit
Ceiling Mounted Dimensions 61
123
73
7
7
186
131 193 235 Air intake
Tubing hole position on wall surface (Figure shows view from front)
Capacity
3 4
Air discharge
Over 250
Service space
9 2
96
90 (Left drain position) (Closed with rubber stopper at time of shipment.)
86 (Gas tubing) 70 (Liquid tubing) 90 (Right drain position)
5HP
3 4
2.5HP
3HP
4HP
S-71PT2R5A
S-100PT2R5A
S-100PT2R5A
S-125PT2R5A
S-125PT2R5A
S-140PT2R5A
S-140PT2R5A
Outdoor Unit
U-60PE1R5A
U-71PE1R5A
U-100PE1R5A
U-100PE1R8A
U-125PE1R5A
U-125PE1R8A
U-140PE1R5A
U-140PE1R8A 3-Phase/ 50Hz
6HP
Phase/Hz
1 Phase/ 50Hz
1 Phase/ 50Hz
1 Phase/ 50Hz
3-Phase/ 50Hz
1 Phase/ 50Hz
3-Phase/ 50Hz
1 Phase/ 50Hz
V
230V | 240V
230V | 240V
230V | 240V
400V | 415V
230V | 240V
400V | 415V
230V | 240V
400V | 415V
kW
6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0)
7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0)
10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)
10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0)
12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)
12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0)
14.0 (3.3 - 15.0) 16.0 (4.1 - 18.0)
14.0 (3.3 - 15.0) 16.0 (4.1 - 18.0)
BTU/h
20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300)
24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700)
34,100 (11,300 - 42,700) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 38,200 (14,000 - 47,800)
42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)
42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600)
47,800 (11,300 - 51,200) 54,600 (14,000 - 61,400)
47,800 (11,300 - 51,200) 54,600 (14,000 - 61,400)
W/W
4.03 : 4.02
3.68 : 4.15
3.95 : 4.31
3.95 : 4.31
3.35 : 3.99
3.35 : 3.99
3.01 : 3.67
3.01 : 3.67
Cooling : Heating
kW
1.49 : 1.74
1.93 : 1.93
2.53 : 2.60
2.53 : 2.60
3.73 : 3.51
3.73 : 3.51
4.65 : 4.36
4.65 : 4.36
Current
Cooling : Heating
A
0.41 : 0.41 | 0.40 : 0.40
0.44 : 0.44 | 0.43 : 0.43
0.67 : 0.67 | 0.65 : 0.65
0.67 : 0.67 | 0.65 : 0.65
0.86 : 0.86 | 0.83 : 0.83
0.86 : 0.86 | 0.83 : 0.83
0.91 : 0.91 | 0.88 : 0.88
0.91 : 0.91 | 0.88 : 0.88
Dimensions
H×W×D
mm
235×1,275×690
235×1,275×690
235×1,590×690
235×1,590×690
235×1,590×690
235×1,590×690
235×1,590×690
235×1,590×690
kg
33
33
40
40
40
40
40
40
L/s
333 : 333
350 : 350
500 : 500
500 : 500
566 : 566
566 : 566
583 : 583
583 : 583
Pa
-
-
-
-
-
-
-
-
EER : COP Total power input
186
Tubing hole position on wall surface (Figure shows view from front)
S-60PT2R5A
Cooling capacity : Heating capacity
80
Service space
Indoor Unit
Power source
Over 250
1590
216
216
90 (Left drain position) (Closed with rubber stopper at time of shipment.)
6
6
96
86 (Gas tubing) 70 (Liquid tubing) 90 (Right drain position)
Optional Controller
ECONAVI sensor CZ-CENSC1
High-spec wired remote controller CZ-RTC3
Timer remote controller CZ-RTC2
Wireless remote controller CZ-RWST3
Wireless remote controller CZ-RWSK2 + CZ-RWSC3
Simplified remote controller CZ-RE2C2
Indoor Unit
Net weight Air volume
Cooling : Heating
External static pressure Sound pressure level (H/M/L)
Cooling : Heating
dB(A)
38 / 34 / 30 : 38 / 34 / 30 39 / 35 / 31 : 39 / 35 / 31 42 / 37 / 35 : 42 / 37 / 35 42 / 37 / 35 : 42 / 37 / 35
Sound power level (H/M/L)
Cooling : Heating
dB(A)
56 / 52 / 48 : 56 / 52 / 48 57 / 53 / 49 : 57 / 53 / 49 60 / 55 / 53 : 60 / 55 / 53 60 / 55 / 53 : 60 / 55 / 53
64 / 58 / 54 : 64 / 58 / 54 64 / 58 / 54 : 64 / 58 / 54 65 / 59 / 55 : 65 / 59 / 55 65 / 59 / 55 : 65 / 59 / 55
3
3
3
3
3
3
3
3
mm
VP-20
VP-20
VP-20
VP-20
VP-20
VP-20
VP-20
VP-20
Number of fan speed Drain pipe size
1 8
4
5
Service space
2
216
176
Approx. 2°
131 193 235 Service space
80
690
1584
176
Minimum 50cm
Over 250
1275
9
Model Name
1 8
Minimum 50cm
216
15
690
4
15 Approx. 2°
Air intake
Over 250
S-100PT2R5A S-125PT2R5A S-140PT2R5A
1541 (Suspension bolt pitch)
1269
Air discharge
114
114
S-60PT2R5A S-71PT2R5A
1226 (Suspension bolt pitch)
5
Indoor Units:
265 190 (Suspension bolt pitch)
Indoor Units:
61 73
123
Drain port VP20 (inside diameter ø26mm, drain hose supplied) Left drain position R efrigerant liquid tubing (ø9.52mm, flare connection) R efrigerant gas tubing (ø15.88mm, flare connection) Left side drain hose outlet port (cutout) Tubing hole on wall surface (ø100mm) Upper side tubing port Right side drain hose outlet port (cutout) Wireless remote controller receiver installation location
265 190 (Suspension bolt pitch)
1 2 3 4 5 6 7 8 9
46 / 40 / 36 : 46 / 40 / 36 46 / 40 / 36 : 46 / 40 / 36 47 / 41 / 37 : 47 / 41 / 37 47 / 41 / 37 : 47 / 41 / 37
Outdoor Unit Current
Cooling : Heating
A
6.90 : 7.80 | 6.70 : 7.60
8.70 : 8.60 | 8.40 : 8.30
11.1 : 11.4 | 10.6 : 11.0
3.75 : 3.85 | 3.65 : 3.75
16.4 : 15.4 | 15.8 : 14.9
5.55 : 5.20 | 5.35 : 5.05
20.5 : 19.2 | 19.8 : 18.5
6.95 : 6.50 | 6.70 : 6.25
Dimensions
H×W×D
mm
996 × 940 × 340
996 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340
1,416 × 940 × 340 98
Net weight
28
PAC_2014_15_1.indd 28-29
kg
68
69
98
98
98
98
98
Air volume
Cooling : Heating
L/s
1,000: 1,000
1,000: 1,000
1,833: 1,583
1,833: 1,583
2,166: 1,833
2,166: 1,833
2,250: 2,000
2,250: 2,000
Sound pressure level
Cooling : Heating
dB(A)
48 : 50
48 : 50
52 : 52
52 : 52
53 : 53
53 : 53
54 : 55
54 : 55
Sound power level
Cooling : Heating
dB(A)
65 : 67
65 : 67
69 : 69
69 : 69
70 : 70
70 : 70
71 : 71
71 : 71
Piping connections
Liquid/Gas
m
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Pipe length
min. - max.
m
5 - 50
5 - 50
5 - 75
5 - 75
5 - 75
5 - 75
5 - 75
5 - 75
Elevation difference (OU located lower, OU located higher)
m
15, 30
15, 30
15, 30
15, 30
15, 30
15, 30
15, 30
15, 30
Maximum chargeless length
m
30
30
30
30
30
30
30
30
Refrigerant at shipping, Additional gas amount
g
R410A 2,000, 50 (g/m)
R410A 2,350, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
R410A 3,400, 50 (g/m)
Operation ranges
˚C
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
-15 to 46 : -20 to 24
Cooling : Heating
29
2014/09/08 15:51
Controllers
Controllers
ECONAVI Sensor [CZ-CENSC1]
NEW Utilises ECONAVI Sensor and Control Program technologies to detect where energy is normally wasted and selfadjusts cooling power to reduce energy waste.
A wide variety of control options to meet the requirements of different applications.
• Activity detection • Absence detection
OPERATION SYSTEM Requirements
INDIVIDUAL CONTROL SYSTEMS
High-spec operation
Normal operation
TIMER OPERATION
Operation from anywhere Quick and easy operation in the room
Daily and weekly program
CENTRALISED CONTROL SYSTEMS
Operation with various function Only ON/OFF operation from from center station center station
Simplified load distribution ratio (LDR) for each tenant Touch screen panel
New
BMS System PC Base
P-AIMS Basic Software
Connection with 3rd Party Controller Seri-Para I/O unit for outdoor unit
External appearance CZ-CAPDC2 High-spec Wired Remote Controller
CZ-CSWKC2
Timer Remote Controller (Wired)
Wireless Remote Controller
CZ-RTC3
CZ-RTC2
CZ-RWSU2 CZ-RWSC3 CZ-RWST3
CZ-RE2C2
CZ-ESWC2
ECONAVI on/off control
l l
l —
l —
l —
Number of indoor units which can be controlled
1 group, 8 units
1 group, 8 units
1 group, 8 units
1 group, 8 units
Type, model name
Built-in thermostat
Use limitations
Function ON/OFF Mode setting Fan speed setting Temperature setting Air flow direction Permit/Prohibit switching Weekly program
·U p to 2 controllers can · Up to 2 controllers can · Up to 2 controllers can be connected per be connected per be connected per group (When using group. group. ECONAVI sensor, only one remote controller is possible to connect at indoor unit)
l l l l l l l
l l l l l — l
l l l l l — —
Simplified Remote Controller
·U p to 2 controllers can be connected per group.
l l l l l — —
Schedule Timer
ON/OFF Controller
Intelligent Controller
CZ-64ESMC2
CZ-ANC2
CZ-256ESMC2 (CZ-CFUNC2)
— —
— —
— —
— —
64 groups, max. 64 units
64 groups, max. 64 units
16 groups, max. 64 units
64 units x 4 links, max. 256 units
·R equired power supply from the system controller ·W hen there is no system controller, connection is possible to the T10 terminal of an indoor unit.
— — — — — — l
System Controller
·U p to 10 controllers, can be · U p to 8 controllers (4 main ·A communication adaptor connected to one system. units + 4 sub units) (CZ-CFUNC2) must be ·M ain unit/sub unit (1 main can be connected to one installed for three or more unit + 1 sub unit) connection system. links. is possible. ·U se without remote controller ·U se without remote controller is impossible. is possible.
l l l l l¹ l —
l — — — — l —
l l l l l¹ l l
Interface adaptor Optional software
CZ-CAPC2
CZ-CSWAC2 for Load distribution CZ-CSWWC2 for Web application CZ-CSWGC2 for Object layout display CZ-CSWBC2 for BACnet software interface *PC required (field supply)
Web Interface Systems
Seri-Para I/O unit for each indoor unit
CZ-CAPBC2
Communication Adaptor CZ-CFUNC2
LonWorks Interface
CZ-CWEBC2 *PC required (field supply) CZ-CLNC2
1. Setting is not possible when a remote control unit is present. (Use the remote controller for setting.) All specifications subject to change without notice.
30
PAC_2014_15_1.indd 30-31
31
2014/09/08 15:51
Controllers
Individual Control Systems
High-spec wired remote controller (CZ-RTC3)
Control contents
Part name, model No.
Quantity
Standard Control • Control of the various operations of the indoor unit by wired or wireless remote controller. • Cooling or heating mode of the outdoor unit is decided by the first priority of the remote controller. • Switching between remote controller sensor and body sensor is possible.
Timer remote controller CZ-RTC2 / CZ-RTC3 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSU2 / CZ-RWSC3 / CZ-RWST3
1 unit each
(1) Group control • Batch remote control on all indoor units. • Operation of all indoor cells in the same mode. • Up to 8 units can be connected. • The sensor is the body sensor, and thermostat ON/OFF setting in regard to the temperature set by the remote controller is possible for each indoor unit.
Timer remote controller CZ-RTC2 / CZ-RTC3 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSU2 / CZ-RWSC3 / CZ-RWST3
(2) Main/sub remote control • Max 2 remote controllers per indoor unit. (Main remote controller can be connected) • The button pressed last has priority. • Timer setting is possible even with the sub remote controller. When using ECONAVI sensor, only one remote controller is possible to connect at indoor unit.
Main or sub Timer remote controller CZ-RTC2 / CZ-RTC3 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSU2 / CZ-RWSC3 / CZ-RWST3
SYSTEM EXAMPLE
NEW Basic Operation
1 unit
Dimensions H 120 x W 120 x D 16 mm
As required
• Individual Louver Control (Lock individual flap for 4-way cassette) • ON/ OFF timer • Weekly Timer • Filter information* • Outing function • Quiet operation mode* • Power consumption monitor* • Energy saving • Initial settings • Ventilation
Energy Saving
Maintenance Function
• ECONAVI on/ off* • Temperature Auto Return • Temperature Setting Range • Auto Shutoff • Schedule peak cut • Repeat off timer
• Outdoor unit error data • Service Contact address • RC setting mode • Test Run • Sensor Information • Service check • Simple/ Detailed Settings • Auto address * Depending on the model, some menus cannot be used.
Timer remote controller (CZ-RTC2) Weekly Programme Function Remote controller Standard control
Main
Sub
(2) Main/sub remote control
Main
• A maximum of 6 settings/day and 42 settings/week can be programmed.
Sub
(1) Group control
Outing Function • This function can prevent the room temperature from dropping or rising when the occupants are out for a long time.
Sleeping Function Dimensions H 120 x W 120 x D 16 mm
Basic remote controller ON/OFF • Operation mode changeover (Cooling, Heating, Dry, Auto, Fan). • Temperature setting (Cooling/Dry: 18-30 deg Heating: 16-30 deg). • Fan speed setting H/ M/ L and Auto. • Air flow direction adjustment.
• This function controls the room temperature for comfortable sleeping.
Max. 8 indoor units can be controlled from one remote controller Remote control by main remote controller and sub controller is possible Max. 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit.
Time Function 24 hours real time clock • Day of the week indicator.
32
PAC_2014_15_1.indd 32-33
33
2014/09/08 15:51
Controllers
Wireless remote controller
System controller (CZ-64ESMC2)
Remote control by main remote controller and sub controller is possible • Max. 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit. For 4-Way cassette type CZ-RWSU2
When CZ-RWSC3 is used, wireless control becomes possible for all indoor units • When a separate receiver is set up in a different room, control from that room also becomes possible. •A utomatic operation by means of the emergency operation button is possible even when the remote controller has been lost or the batteries have been exhausted.
In addition, there are other functions such as temperature setting, operation switching, wind direction/fan speed setting, etc Ventilation independent operation is possible For all indoor units CZ-RWSK2 + CZ-RWSC3
When commercial ventilation fans or heat-exchange ventilation fans have been installed, they can be operated with this remote control (interlocked operation with the indoor unit or independent ventilation ON/OFF).
• A control mode corresponding to the use condition can be selected from 10 patterns
Power supply: AC 220 to 240 V I/O part: Remote input (effective voltage: DC 24 V): All ON/All OFF Remote output (voltage-free contact): All ON/All OFF (external Power supply within DC 30 V, max 1 A) Total wiring length : 1 km
A : Operation mode: Central control mode or remote control mode can be selected Central control mode: The system controller is used as centralised control device. (Setting from a remote controller can be prohibited by prohibiting local operation from the system controller.) Remote control mode: The system controller is used as a remote controller. (Setting from the system controller can be prohibited by prohibiting local operation from another central control unit.)
Individual control is possible for max 64 groups, 64 indoor units. • Control of 64 indoor units divided into 4 zones. (One zone can have up to 16 groups, and one group can have up to 8 units.) • Control is possible for ON/OFF, operation mode, fan speed, air flow direction (only when used without a remote controller), operation monitoring, alarm monitoring, ventilation, remote controller local operation prohibition, etc. Individual All operations are possible also from the remote controller. However, the contents will be changed to the contents of the controller operated last. Central 1 The remote controller cannot be used for ON/OFF. (All other operations are possible from the remote controller.) Central 3 The remote controller cannot be used for mode change or temperature setting change. (All other operations are possible from the remote controller.) Central 4 The remote controller cannot be used for operation mode change. (All other operations are possible from the remote controller.)
For ceiling mounted type CZ-RWST3
Simplified remote controller (CZ-RE2C2) A remote controller with simple functions and basic operation • Suitable for open rooms or hotels where detailed functions are not required. • ON/OFF, operation mode switching, temperature setting, wind velocity switching, wind direction setting, alarm display, and remote controller self-diagnosis can be performed. • Batch group control for up to 8 indoor units. •R emote control by main remote controller and sub controller is possible with a simplified remote controller or a wired remote controller (up to two units). Dimensions H 120 x W 70 x D 17 mm
Dimensions 160 x W 160 x D 21 + 69 (embedding dimension mm)
A Operation mode
B Controlled unit number mode
Central control mode
Remote control mode
All mode
All central control Example 1
All remote control
Zone 1 mode
Zone 1 central control Example 2
Zone 1 remote control
Zone 2 mode
Zone 2 central control
Zone 2 remote control Example 3
Zone 3 mode
Zone 3 central control Example 4
Zone 3 remote control
Zone 4 mode
Zone 4 central control
Zone 4 remote control Example 5
(The maximum number of connectable system controllers is 10, including other central controllers on the same circuit.) (In case of joint use with a wireless remote controller, there are limitations for the control mode. Please use only with “Individual” and “Central 1”.)
• Control of systems without a remote controller and of main/sub systems (a total of up to 2 units) is possible Connection example 2 (POWER SUPPLY FROM THE CENTRAL CONTROLLER) Indoor/outdoor operation wire Schedule timer
System controller
Zone 1 Centralised addresses 1 to 16
Zone 3 Centralised addresses 33 to 48
Zone 4 Centralised addresses 49 to 64
PAC_2014_15_1.indd 34-35
Connection example
• Joint use with a remote controller, an intelligent controller, a schedule timer, etc. is possible
Zone 2 Centralised addresses 17 to 32
34
B : Controlled unit number mode: All mode or zone 1, 2, 3, 4 mode can be selected All mode: All, zone, or group unit can be selected. Zone 1, 2, 3, 4 mode: Setting is possible only for the indoor units of zone 1, 2, 3, or 4.
Timer group 1: Centralised addresses 1 to 8
Timer group 2: Centralised addresses 9 to 16
Timer group 3: Centralised addresses 17 to 24
Timer group 4: Centralised addresses 25 to 32
Timer group 5: Centralised addresses 33 to 40
Timer group 6: Centralised addresses 41 to 48
Timer group 7: Centralised addresses 49 to 56
Timer group 8: Centralised addresses 57 to 64
35
2014/09/08 15:51
Controllers
Centralised Control Systems
ON/OFF controller (CZ-ANC2) • 16 groups of indoor units can be controlled. • Collective control and individual group (unit) control can also be performed. • Up to 8 ON/OFF controller (4 main, 4 sub) can be installed in one link system. • The operation status can be determined immediately.
Schedule timer (CZ-ESWC2) • A function for pausing the timer in case of national holidays has been added, and timer operation also can be stopped for a long time
Dimensions H 120 x W 120 x D 16 mm
Up to 64 groups (max 64 indoor units) can be controlled divided into 8 timer groups • Six program operations (Operation/Stop/ Local permission/ Local prohibition) per day can be set in a program for one week · Only operation or stop, remote controller local permission or remote controller local prohibition, and their respective combinations are possible. (Operation + local permission, stop + local prohibition, only local permission, etc.) · Local prohibition and the combination of the three items of temperature setting, mode change, and operation/stop can be set at the time of installation.
·B y setting holidays or operation stop within one week, the timer can be paused just for that week. ·A ll timer settings can be stopped with the timer “ON/OFF effective” button. (Return to timer operation is made by pressing the button again.)
The power supply for the schedule timer is taken from one of the following. 1. Control circuit board (T10) of a nearby indoor unit (power supply wiring length: within 200m from the indoor unit). 2. System controller (power supply wiring length: within 100 m from the indoor unit). When the power supply for the schedule timer is taken from the control circuit board of the indoor unit, that indoor unit cannot be used with other control devices using the T10 terminal. As operation mode and temperature settings are not possible with the schedule timer, it must be used together with a remote controller, a system controller, an intelligent controller, etc. Also, as it does not have an address setting function, the control function of a system controller etc. must be used for address setting.
Dimensions H 121 x W 122 x D 14 + 52 (embedding dimension mm) Power supply: I/O part:
AC 220 to 240 V Remote input (effective voltage: within DC 24 V): All ON/OFF Remote output (allowable voltage: within DC 30 V): All ON, All alarm
Web Interface Systems Web Interface (CZ-CWEBC2) Functions
Connection example 1 (POWER SUPPLY FROM THE INDOOR UNIT)
(Dimensions: H 248 x W 185 x D 80 mm) AC 100 to 240 V (50/60Hz), 17 W
Remote controller
Schedule timer
Note: As operation mode and temperature settings are not possible with the ON/OFF controller, it must be used together with a remote controller, a system controller etc.
• All Units control • Alarm Log • Mail Sent Log • Program Timer set 50 daily timers with 50 actions each day, 50 weekly timers 50 weekly timers, 1 holiday timer, 5 special day timers, for each tenant • Prohibit Remote Control set • IP ADDRESS could be changed via Internet
• Access and operation by Web browser • Icon display • Language codes available in English, French, German, Italian, Portguese, Spanish • Individual control possible (max. 64 indoor units) ON/OFF operation mode, set temperature, fan speed, Flap set, timer on/off, alarm code monitoring, prohibit Remote Control • Zone control *
Note: It is recommended to install a remote controller or a system controller on site to enable local control if it network experience a problem.
*Power supply
Easy to set to every room by recognizable icon and user-friendly remote control window If any of the indoor units is selected, the remote control window shown will be displayed for detailed setting modifications.
Easy to manage and monitor each tenant use * Each indoor unit or tenant otherwise all the indoor units can be displayed and controlled. All unit statuses can also be displayed on one screen.
Program Timer set
Web Interface (CZ-CWEBC2) Indoor/outdoor Link system control wire (non-polar)
LAN (10/100BASE-T)
Intranet
Maximum number of connections: Indoor units: 64 Outdoor units: 30 Link system (Indoor/outdoor control wire) : 1
PC (field supply)
50 daily timers with 50 actions each day, 50 weekly timers, holiday timer, 5 special day timers, for each tenant
36
PAC_2014_15_1.indd 36-37
37
2014/09/08 15:51
Controllers
Intelligent controller (CZ-256ESMC2) • Limitation contents for prohibited operation Prohibition means limitation of the operation contents from the remote controller. It is also possible to change the prohibition items.
Touch panel
Limitation contents (Limitations can be user defined) Individual
Dimensions H 240 x W 280 x D 138 mm Power supply AC 100 to 240 V (50 Hz), 20 W (separate power supply) I/O part Remote in put (voltage-free contact): All ON/OFF Remote output (voltage-free contact): All ON, All alarm (external power supply within DC 30 V, 0.5 A) Total wiring length: 1 km for each system Only for embedding in the panel
Prohibition 1
Prohibition 2
Prohibition 3
• Max 256 indoor units (4 systems x 64 units) can be controlled. In case of three or more systems (more than 129 units), a communication adapter CZ-CFUNC2 must be installed on the outside • Operation is possible as batch, in zone units, in tenant and in group units • ON/OFF, operation mode setting, temperature setting, for fan speed setting, air flow direction setting (when used without a remote controller), and remote controller local operation prohibition (prohibition 1, 2, 3, 4) can be done • A system without a remote controller is possible. Joint use with a remote controller or a system controller is also possible • Use of a schedule timer and holiday setting also can be done • Proportional distribution of the air conditioning energy is possible. Including csv-file export via CF-card (supplementary accessory) • Pulse signal input from electric/gas consumption meter
Prohibition 4
There is no limitation for the operation of the remote controller. However, the contents will be changed to the contents of the controller operated last. (Lastpressed priority.) The remote controller cannot be used for ON/OFF. (All other operations are possible from the remote controller.) The remote controller cannot be used for ON/OFF, operation mode change and temperature setting. (All other operations are possible from the remote controller.) The remote controller cannot be used for operation mode change and temperature setting. (All other operations are possible from the remote controller.) The remote controller cannot be used for operation mode change. (All other operations are possible from the remote controller.)
Linked system No. 1
Intelligent controller CZ-256ESMC2
Linked system No. 2 System signal x 4 RS 485 (Polarity shield wire) Linked system No. 3
Communication adapter CZ-CFUNC2
Linked system No. 4
System signal x 4
Display sample Max. 4 links can be connected for the indoor/outdoor
operation line = Max. 64 indoor units x 4 (256 units) Max. 30 outdoor units x 4 (120 units)
Communication adaptor (CZ-CFUNC2)
In case of joint use with a wireless remote control system, there are limitations for the control mode. Please use only with “Permission” and “Prohibition 1”.
Web application
* Required when more than 129 indoor units are connected.
38
PAC_2014_15_1.indd 38-39
39
2014/09/08 15:51
Controllers
Panasonic total air conditioning management system
P-AIMS
P-AIMS Basic software / CZ-CSWKC2
P-AIMS optional software CZ-CSWAC2 for Load distribution
Up to 1024 indoor units can be controlled by one PC
Load distribution calculation for each tenant
Functions of basic software
• Air-conditioner load distribution ratio is calculated for each unit (tenant) with used energy consumption data (m3, kWh). • Calculated data is stored with CSV type file. • Data of last 365 days is stored
• Standard remote control for all indoor units • Many timer schedule programs can be set on the calender • Detailed information display for alarms • CSV file output with alarm history, operating status. • Automatic data backup to HDD
P-AIMS optional software CZ-CSWWC2 for Web application Web access & control from remote station
With 4 upgrade packages the basic software can be upgraded to suit individual requirements
• Accessing P-AIMS software from remote PC. • You can monitor/operate FSV systems by using Web browser (Internet Explorer).
CZ-CFUNC2
The P-AIMS is ideal for large areas/buildings such as shopping centers, universities and office buildings. Up to eight Communication Adaptors (C/A) can be connected to a P-AIMS to enable control of 1024 indoor units with one “P-AIMS” PC.
User PC
Converter
Building A
(Field supply)
USB line
P-AIMS optional software CZ-CSWGC2 for Object layout display
RS485 (Polarized)
• Operating status monitor is available on the layout display. • Object’s layout and indoor unit’s location can be checked at once. • Each unit can be controlled by virtual remote controller on the display. • Max 4 layout screens are shown at once.
Communication Adaptor
PC Environment: Windows 7 Professional (32bit) or Windows XP Professional (32bit) CPU: Intel Core™ i3-2100 processor or higher Memory: 2GB or over HDD: 100GB or over • Wiring length (PC~C/A) Max. 1 km Max. 8 C/A for 1 system • Wiring length for each link from C/A Max. 1 km
Whole system can be controlled visually
Building B
Building D
P-AIMS optional software CZ-CSWBC2 for BACnet software interface Connectable to BMS system • Can communicate with other equipment by BACnet protocol. • FSV systems can be controlled by both BMS and P-AIMS. • Max 255 indoor units can be connected to 1 PC (that has P-AIMS basic & BACnet software).
40
PAC_2014_15_1.indd 40-41
41
2014/09/08 15:51
Controllers
T10 Terminal for External Control (Digital Connection)
Serial Interface for 3rd Party External Controller
Connecting an FSV indoor unit to an external device is easy. The T10 Terminal featured in the electronic circuit board of all indoor units enables digital connection to external devices.
Example of 3rd party BMS connection with CZ-CFUNC2 (For the detail pleace consult to authorized dealer)
Functions via communication adaptor [CZ-CFunC2] Unit ON/OFF Mode-change
Communication adaptor (CZ-CFUNC2)
Room temperature setting A/C unit settings
Fan speed setting Flap setting Central control setting Filter-sign clear Alarm reset Unit ON/OFF status Operation mode Setting temperature
1. T10 Terminal Specification (T10:CN061 at indoor unit PCB) 1
• ControlCOM items: 1. Start/stop input 2 3 2. Remote controller prohibit input 4 3. Start signal output +12V COM 5 T10 4. Alarm signal output (yellow)
• Example of wiring
Flap status Central control setting Filter-sign situation
1
Up to 128 indoor units can be connected to one Communication Adaptor.
Correct/incorrect status
COM 2
Alarm code
3
6
4 300msec. or more
T10 (yellow)
1-2 (pulse input)
ON
OFF
COM 5
Condition
+12
4-5 (output)
Unit condition
Fan speed status A/C unit status
ON
NOTE: The wire length from indoor unit to the Relay must be within 2.0m. Pulse signal changeable to static with JP cutting. (Refer to JP001)
+12V
6
300msec. or more
1. 1-2 (Pulse input): Unit ON/OFF condition switching with a pulse signal. (1 1-2pulse (pulse input) signal: shortage status more than 300msec.or more) 2. 2-3 (Static input): Open/ Operation with Remote is permitted.(Normal condition) Close/ Remote controller is prohibited. +12 the unit ON. / No output at OFF. 3. 4-5 (Static output): 12V output during 4-5 (output) 4. 5-6 (Static output): 12V output when some errors occur / No output at normal.
Unit condition
ON
OFF
ON
2. Usage Example Forced OFF control
Operation ON/OFF signal output
• Condition
• Condition
1-2 (Static input): Close/ Operation with Remote is permitted. (Normal condition) Open/ Unit is forcibly OFF and Remote controller operation is prohibited.
4-5 (Static output): 12V output during the unit ON / No output at OFF
• Example of wiring
• Example of wiring
Relay (Field supply) T10 (YEL)
Relay (Field supply) T10 (YEL)
Indoor unit control PCB
POWER
External contact (Card switch box, etc.: field supply)
NOTE: The wire length from indoor unit to the Relay must be within 2.0m
42
PAC_2014_15_1.indd 42-43
Central control
The contact in the figure is a state where the card is pulled out.
Indoor unit control PCB
2m
NOTE: The wire length from indoor unit to the Relay must be within 2.0m Pulse signal changeable to static with JP cutting. (Refer to JP001)
43
2014/09/08 15:52
Controllers
Interfaces for External Control (Digital Connection) Seri-Para I /O unit for outdoor unit (CZ-CAPDC2) Dimensions H 80 x W 290 x D 260 mm Power supply Single phase 110-120/220-240 V AC (50/60 Hz), 18 W Input Batch operation/Batch stop (non-voltage contact/DC 24 V, pulse signal). Cooling/ Heating (non-voltage contact/static signal). Demand 1/2 (non-voltage contact/ static signal) (Local stop by switching) Output Operation output (non-voltage contact). Alarm output (non-voltage contact) Wiring length Indoor/Outdoor operation lines: Total length 1 km. Digital signal: 100 m or shorter
• This unit can control up to 4 outdoor units. •F rom the centre control device, mode changing and batch operation/batch stop are possible. • Required for demand control.
Interface adaptor (CZ-CAPC2) • Control and status monitoring is possible for individual indoor unit (or any external electrical device up to 250 V AC, 10 A) by contact signal.
System example CZ-CAPC2
For example: fan coil unit etc. Total heat exchanger unit.
ON/OFF controller
System example Seri-para I/O
LonWorks Interface (CZ-CLNC2)
Central Control Device
• This interface is a communications converter for connecting LonWorks to the control network of FSV. • From the host connected to LonWorks, basic settings and status monitoring is possible for up to 16 groups of indoor units.
System example
Seri-Para I/O unit for each indoor unit (CZ-CAPBC2) • Control and status monitoring is possible for individual indoor unit (1 group). • In addition to operation and stop, there is a digital input function for air speed and operation mode. • Temperature setting and measuring of the indoor suction temperature can be performed from central monitoring. • The analog input for temperature setting is 0 to 10 V, or 0 to 140 Ohm. • Power is supplied from the T10 terminal of the indoor units. • Separate power supply also is possible (in case of suction temperature measuring).
System example Remote station
Indoor/outdoor unit control line LON
• System Controller
A/C unit settings from the LonWorks communicator
Settings for each group of indoor units Settings for all units
A/C unit status notifications made to the LonWorks communicator
Central control panel Configuration properties
PAC_2014_15_1.indd 44-45
LON
LonWorks communication line
Center Control Device (field supply)
Functions
CZ-CAPBC2
44
LonWorks Interface
Start/stop Temp. setting Operation mode Option 1 settings Option 2 settings Emergency stop Start/stop Temp setting Operation mode Option 1 settings Option 2 settings Alarm status Indoor units with active alarms Room temp. A/C unit status Transmission intervals settings Minimum time secured for transmission
45
2014/09/08 15:52
Controllers
Remote Controller External Dimensions TIMER REMOTE CONTROLLER (CZ-RTC2)
COMMUNICATION ADAPTOR (CZ-CFUNC2)
INTELLIGENT CONTROLLER (CZ-256ESMC2)
290 270
80
38
HIGH-SPEC WIRED REMOTE CONTROLLER (CZ-RTC3)
38
180
256
120
16
R 2.5 79
120
8 R5
ø22.2 (mm)
SEPARATE RECEIVER FOR WIRELESS REMOTE CONTROLLER (CZ-RWSC3)
ON/OFF CONTROLLER (CZ-ANC2)
SERI-PARA I/O UNIT FOR EACH INDOOR UNIT (CZ-CAPBC2)
116
20
WIRELESS REMOTE CONTROLLER
6
160 148
(6)
14
69
121
160 148
SIMPLIFIED REMOTE CONTROLLER (CZ-RE2C2)
SYSTEM CONTROLLER (CZ-64ESMC2)
(6)
Unit: mm
115
120
6
70
122
LONWORKS INTERFACE (CZ-CLNC2)
116
SERI-PARA I /O UNIT FOR OUTDOOR UNIT (CZ-CAPDC2)
66.8
17
70
4.4
16.7
10
21
69
6
4 - Ø 5 hole
115
121
148
4.4 160
8
(6)
116.8
83.5
5.4
160 148
6
9.4 33.5
16.6
120
9.4
Potbellied hole (4 locations)
3 - Ø 30 hole
13 (6)
33.4 121
Magnified view Detail of the potbellied hole
ECONAVI SENSOR (CZ-CENSC1)
46
PAC_2014_15_1.indd 46-47
REMOTE SENSOR (CZ-CSRC2)
47
2014/09/08 15:52