VPInstruments Catalog 2014-2015

Page 1

Energy Management solutions for compressed air and industrial gases

vp i n s t r um e n t s. com


‘ Vision is really a powerful tool to keep our compressed air consumption at the lowest possible level. It helps us to prevent leakage and to optimize our compressed air supply.’ - Kikkoman Europe

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


Introduction | VPINSTRUMENTS

3

Our mission VPInstruments develops, produces and supplies energy management solutions for compressed air and industrial gases. We show you where, when and how much you can save. Our solutions cover both supply side and demand side. We offer a unique product range consisting of: > Flow meters and other sensors for compressed air > Monitoring systems for total compressed air management > Easy to use tools for installation VPInstruments is one of the most innovative companies in its industry. Our products and solutions are often unique in the market, easy to use, sustainably produced, and designed with two eyes for detail, which is reflected in our logo. Our products are sold through skilled distributors worldwide. Thanks to their skills and expertise, they can help you to get most out of our products. We take quality and traceability very serious. Our calibration systems are traceable to the National Standards at NMi (Dutch Institute of Standards and Metrology). Our quality management system is certified to ISO 9001:2008.

Proudly serving leading companies worldwide Through our distributors and dealers, we serve clients worldwide to save on compressed air energy costs. A small selection of end users: Astrum UK (Steel castings), Bolletje (Food), GSK (Medicines), Kikkoman Foods, Libbey (Glass), Mars (Food), Nedstaal (Steel production), Nestlé (Food), O&I (Glass), Philips (Consumer goods), Rexam (Glass), Toyota (Automotive).

Histor y In 1974, Anton van Putten develops world’s first solid state flow sensor. In 1999, VPInstruments is founded by Pascal van Putten, and wins the McKinsey New Venture ’98 competition. In 2007, The VPFlowScope product line is launched. For the first time, mass flow, pressure and temperature can be measured with a single probe. In 2009, VPVision is introduced. The complete solution for compressed air energy management. In 2011, The VPFlowScope Differential Pressure flow meter is introduced. Now you can perform air audits in wet, condensing air conditions. In 2012, VPInstruments sets the new standard for webbased compressed air energy management. Open US Service center.

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


4

Introduction | VPINSTRUMENTS

Technology Thermabridge- leading sensor technology since 1974 Our co-founder Anton Van Putten invented world’s first solid state thermal mass flow sensor back in 1974. We are proud to continue the heritage of making cutting edge products based upon this unique and patented sensor technology.

Working principle The unique Thermabridge™ sensors are integrated circuits, just like computer chips. They combine a heater with a Wheatstone bridge. The heater keeps the sensor on a constant temperature. The Wheatstone bridge is used for temperature control and direction measurement.

Direction sensitivity. Invented by VPInstruments The VPFlowScope combines an extremely large measurement range with integrated direction sensitivity. This patented feature enables you to measure in loop networks, and in systems with air receivers. These situations used to be very difficult to assess. With the VPFlowScope, flow direction is no longer a mystery.

Modbus - the industry standard The VPFlowScope provides a Modbus-RTU interface, which opens the door to many energy management software packages and building management systems. No secret protocols or expensive configuration tools needed.

Sensing the future Since 1974, the founders of VPInstruments have invested over 35 years in research and development. We will continue to do so, to enhance our products and our technology, in our effort to provide the best possible solutions for mass flow measurement of compressed air and technical gases.

The unique Thermabridge™ sensors combine a heating element with a Wheatstone bridge.

Flow

CAT-VP-1409-WO

Flow

Flow from left

No flow

Flow from right

The left part is cooled down, the right part of the bridge is heated up.

Everything in balance.

Vice versa! Now the left part is heated up, and the right part is cooled down.

© 2014 VPINSTRUMENTS


Introduction | VPINSTRUMENTS

If you can measure it, you can improve it

Measure p11 Use mass flow meters for: > Supply side air: pre-treated wet oily dirty air > Demand side air: clean dry air > Piping systems from 0.5" up to 20", Measuring and recording mass flow, temperature and pressure in a single measuring instrument > Air audits, system checks

Monitor p27 Leave measuring equipment in place to: > Continually know what is happening in your system > Proactively control leaks > Plan your maintenance, based on real-time actions > Monitor dew point, power consumption and pressure loss to prevent downtime

Manage p31 With VPVision you can: > Track and manage your leakage > Allocate compressed air costs to individual departments > Deliver cost evaluation and savings reports > Benchmark different plants around the world on efficiency and costs > Produce necessary documentation for utility incentives

Install p35 We offer a line of tools and accessories for: > Hot tapping: Installation of flow meters under pressurized conditions > Leak detection > Measuring pipe wall thickness

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS

5


6

Introduction | VPINSTRUMENTS

50 30%

Measure, Discover and Save! Compressed air is a very expensive energy source. In fact, it is nearly 10 times more expensive than electricity.

Compressed air consumption

Production Leaks Artificial demand Inappropriate use

Studies show that up to 50% of generated compressed air is still lost due to leakage, incompetent use and overdue maintenance. Our products enable you to chart these losses easily. In many cases, compressed air demand can be reduced by optimizing the compressed air system with proper air management, pressure control, piping configurations and air leak control.

Fact: Only 50% of the generated compressed air is used usefully. The other 50% is being spilled. A management system will help you to reduce this waste of energy and money. And helps you to maintain your consumption as low as possible.

Maximize your ROI Your return on investment can be a matter of months. Take a look at customer savings success stories on our website, and read how our products have helped companies save energy year after year. An n u a l e l e c tri c i ty b i ll kW 25

kW/Year 109,500

Euro

USD

Euro/Year

USD/Year

ROI (days)

€ 16,425

$ 19,710

€ 4,928

$ 5,913

365

37

162,060

€ 24,309

$ 29,171

€ 7,293

$ 8,751

247

55

240,900

€ 36,135

$ 43,362

€ 10,841

$ 13,009

166

125

547,500

€ 82,125

$ 98,550

€ 24,638

$ 29,565

73

250

1,095,000

€ 164,250

$ 197,100

€ 49,275

$ 59,130

37

Equipment investment Leakage/savings potential Production hours per day kW price

CAT-VP-1409-WO

S avi n g s p o t e n t ia l

© 2014 VPINSTRUMENTS

€ 5,000 30% 12 € 0.15

Did you know that a 2 inch in-line meter guards a cash flow of more than 10,000 Euro ($13,000 ) per year? The ROI is in general a matter of months! See our website for more savings examples and calculators.


Introduction | VPINSTRUMENTS

7

Compressed air applications Virtually any production plant utilizes compressed air. Applications are packaging machines, offset presses, transport of granulate and food ingredients, cooling of products, and tank aeration. > Ceramic factories > Glass production > Cement and construction products > Paper > Food production, beverage and breweries

> Life sciences > Automotive > Steel production

Other markets and applications Our products are used successfully in various industrial applications, for example: > Aeration monitoring in water treatment plants > Airflow monitoring in large ducts > General test and measurement applications (like universities) > OEM applications > Combustion air mixing > Technical gas mixing > Welding gas, packaging gas > C02 consumption metering > C02 exhaust metering

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS


8

Introduction | VPINSTRUMENTS

Application examples and start kits We offer start kits, which can be directly applied to your application. Each start kit contains all the items you need for the job.

Portable audit tools The VPFlowScope® measures mass flow, pressure, temperature and features a built-in 500,000 point data logger. The device has a built-in display with keypad for configuration: no need to bring a computer on-site! The start kit is delivered in an heavy duty weather proof transport case. Complete with a portable power supply adapter, cables and VPStudio™ software.

Or der codes VPFlowScope® VPS.R150.P400.KIT VPS.R200.P4DP.KIT

VPFlowScope start kit for dry air VPFlowScope start kit for wet air, high temperature

Demand side measurement For small compressors, demand side and point of use measurement, we offer the VPFlowScope in-line 3 in one mass flow meter with built-in 2 Million point data logger and USB interface. We offer three models that fit virtually all demand side applications. Pip e siz e s

1 2

DN

Thread1

Models

Capa c i t y Qmin (m3n/hr)

Qmax (m3n/hr)

Qmin (scfm)2

Qmax (scfm)2

15

1/2 ‘’

VPS.R080.M050

0.32

60

0.2

35

25

1 ‘’

VPS.R250.M100

0.88

200

0.52

120

50

2 ‘’

VPS.R01K.M200

3.53

1000

2.08

590

All models supplied with BSP thread (straight).For US NPT, you can chase with die. SCFM values are rounded off

Power supply and interface options All power supplies are rated for 90 to 230 V input with 12 to 24 V output and supplied with correct plug for initial country shipped to.

CAT-VP-1409-WO

Or der cod e s De s c rip ti on

A ppli c a t i o n

VPA.0030.100 VPA.0000.100 VPA.0000.005

Fixed, heavy industrial Light industrial, portable use Fixed installations, control panels

© 2014 VPINSTRUMENTS

Power supply, in IP54 box Power supply with M12 connector M12 cable, 5 meter


Introduction | VPINSTRUMENTS

9

Compressed air supply monitoring For overall efficiency and cost monitoring we provide a complete solution. It consists of the VPFlowTerminal wall mount display, the VPFlowScope and an AC current sensor. With an optional dew point sensor, you can also monitor the dew point to make sure it is within the specified range.

Or der codes VPT.5110.000 VPT.5110.001

VPFlowTerminal display with 2 million point Data logger; 4 analog inputs 4 ... 20 mA option

Flow meters VPS.R200.P4DP VPS.R150.P400

Flow, pressure, temperature measurement, for wet air Flow, pressure, temperature measurement, for dry air

Current sensors VPA.8000.2100 VPA.8000.2200 VPA.8000.2400 VPA.8000.21K5

VPLog-i AC current sensor 100A-rms VPLog-i AC current sensor 200A-rms VPLog-i AC current sensor 400A-rms VPLog-i AC current sensor 1500A-rms

Dew point sensors App lication

DEW PO INT

Connection

ORDER CODEs

Adsorption dryer Refrigerant dryer

-100 ... +20°C | -148 ... 68°F -40 ... +60°C | -40 ...140 °F

4 ... 20 mA 2 wire 4 ... 20 mA 3 wire

VPA.8000.1003 VPA.8000.1013

Example: VPFlowTerminal for local data logging > 1 VPFlowScope > 3 parameters on local display > Up to 7 parameters to be logged > Example: 4 analog inputs (4 ... 20 mA) > 2 Current clamps (Amps) > 1 Pressure sensor (Air treatment DP) > 1 dew point meter (Air treatment Quality) > VPFlowScope and all 4 ... 20 mA signals can be patched to DCS

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


10

Introduction | VPINSTRUMENTS

Service and support Service is provided from our main office in Delft and our Authorized Marketing and Service Center in the United States. As the market leader in compressed air flow measurement equipment, VPInstruments has developed unique calibration facilities. Our pressurized calibration systems are state of the art, strictly maintained under the ISO 9001 certified Quality Management System. For continual optimal service, we suggest the VPInstruments Full Service Subscription Program. No downtime: We send you a calibrated meter, and you return the used meter upon receipt.

Or der codes VPA.0001.920 Standard Service Subscription (SSP) 5 year subscription. Includes annual recalibration, firmware update and cleaning of your flow meter. Includes warranty extension up to 5 years. VPA.0001.940 Full Service Subscription (FSP) Exchange Program. Receive annually a calibrated instrument and exchange it for the instrument in your prossession. No service waiting time. Lifetime warranty extension. Includes shipment costs from VPInstruments to client, terms CIF* (Incoterms 2010). (Minimum for 3 years)

Special exchange programs available, check with your Distributor

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS


Measure ‘If you can measure it, you can improve it’ - Lord Kelvin

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


VPFlowScope The VPFlowScope measures mass flow, temperature and pressure simultaneously. It’s the ultimate compressed air audit tool, used by leading auditors worldwide. The bright blue display provides real-time information, and with the built-in data logger, recording is as easy as taking a picture. VPStudio software can be used for real-time measurements on your PC, to process data and to print reports. The VPFlowScope product family consists of a wet and a dry air flow meter, which are fully interchangeable and compatible with the VPFlowScope display modules.

Applications

FlowScope > Mass Flow, Pressure & Temperature > Display/data logger module for easy recording of data > Measures mass flow and direction

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS

> Air audits > Demand side monitoring, sub metering of compressed air > Ring networks (bi-directional) > Air, Nitrogen, Carbon Dioxide, Argon: Any dry and non-corrosive gas.

We offer the VPFlowScope for both wet and dry compressed air. You can combine both the wet and dry sensor module with the same display module. That’s why the VPFlowscope is so exceptional for air auditors. With the VPFlowScope you can measure virtually any compressed air system with a single instrument.


FLOWSCOPE | VPINSTRUMENTS

13

Specifications - Thermal VPFlow Scope Flow sensor Measuring principle Flow range Accuracy Reference conditions Gases Gas temperature range

Thermabridge™ Thermal Mass Flow sensor 0 (0.5) ... 150 mn/sec | 0 ... 500 sfps Bi-directional option (calibrated in positive direction only). 2% of reading under calibration conditions; Please refer to the user’s manual for details. Recommended pipe diameter: 25 mm (1 inch) and up. 0 °C, 1013.25 mbar | 32 °F, 14.65 psi Compressed air, Nitrogen and inert, non condensing gases 0 ... +60 °C | 0 ... +140 °F

Pressure sensor Pressure sensor range Accuracy

0 ... 16 bar | 0 ... 232 psi gage +/- 1.5% FSS Temperature compensated

Temperature sensor Temperature sensor range Accuracy

0 ... +60 °C | 0 ... +140 °F > 10 m/sec: +/- 1 °C | 1.8 °F < 10 m/sec: + 5 °C | 1.8 °F

Data outputs Digital Analog

RS485, MODBUS RTU protocol 4 ... 20 mA output, selectable via software to indicate flow, pressure or temperature

Display/data logger Technology Back light Data logger

Liquid Crystal (LCD) Blue, with auto power save 500,000 points

Mechanical & environmental Probe lengths Process connection Pressure rating Protection grade Ambient temperature range Wetted materials Corrosion resistance

400 mm | 15 inch (other lengths on request) Compression fitting, 0,5 inch PN20, higher pressure on request IP52 | NEMA 12 when mated to display module, avoid upside down installation IP63 | NEMA 4 when mated to connector cap, avoid upside down installation -10 ... +50 °C | 14 ... 122 °F. Avoid direct sunlight or radiant heat Higher ambient temperatures: consult factory Anodized Aluminum, Stainless steel 316, Glass, Epoxy Highly corrosive or acid environments should be avoided

Electrical Connection type Power supply Power consumption UL/ CUL CE

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS

M12, 5 pin connector, female 12 ... 24 VDC +/- 10 % Class 2 (UL) 2,4 Watt (no flow) 4,8 Watt (full flow) +/- 10% 100 mA (no flow). 200 mA (full flow) +/- 10% @24VDC 14 AZ, Industrial Control Equipment EN 61326-1, EN 50082-1


14

FLOWSCOPE | VPINSTRUMENTS

3

4

5

6

Technical drawings

45 1.8

12.70 0.5

A

P300: 290 mm [11.5] P400: 390 mm [15.4] P600: 590 mm [23.3]

120 4.7

B

Or der codes Flow meters VPS.R150.P400.KIT VPFlowScope start kit, for air audits, complete with software VPS.R150.P400.D1 VPFlowScope with data logger display module, for auditors and permanent installation (stand alone) VPS.R150.P400.D2 VPFlowScope with connector cap. For modbus networks

C

Other probe lengths The standard P400 probe is acceptable for most air audits and installations. We offer P300 and P600 probes on request. Material : Drawing nr. : Debur and break sharp edges FinishCable, : VPA.5000.005 Unless otherwise specified M12, 5 pole, for permanent connection dimensions are in VPA.5001.105 millimeters Interface box JB5 with 5m/ 16.4 ft cable + 12 VDC power supply Name : Tolerances : Approvals VPA.5001.900 Linear : NEN-ISO 2768-1-m Connector cap with M12 socket for VPFlowScope sensor module ENG QA PROD Other :NEN-ISO 2768-2-K Further info acc. to : Scale : 1:5 Drawn: "Toleranties VPInstruments NEN ISO 2768" Date : SHEET 1 OF 1 VPS.R150.P400 flow range table

Accessories

VPSR150.P400

A4

All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner.

S chedu le 4 0 Stand a rd S e aml e ss Carb on S te e l P ip e Size (inch)

DN

ID (inch)

ID (mm)

Min flow (scfm)

Max flow (scfm)

(m3n/hr)

Min flow

Schedule 10 Standard Seamless Carbon Steel Pipe

Max flow

(m3n/hr)

ID (inch)

ID (mm)

Min flow (scfm)

Max flow (scfm)

Min flow

(m3n/hr)

Max flow

(m3n/hr)

2

50

2.1

52.5

2

688

4

1,169

2.2

54.8

2

749

4

1,273

3

80

3.1

77.9

5

1,516

9

2,576

3.3

82.8

6

1,712

10

2,908

4

100

4.0

102.3

9

2,610

15

4,435

4.3

108.2

10

2,923

17

4,966

6

150

6.1

154.1

20

5,924

34

10,065

6.4

161.5

22

6,508

37

11,057

8

200

8.0

202.7

34

10,259

58

17,429

8.3

211.6

37

11,173

63

18,982

10

250

10.2

259.1

56

16,756

95

28,468

10.4

264.7

58

17,487

99

29,709

12

300

11.9

303.2

77

22,953

130

38,995

12.4

314.7

82

24,724

140

42,004

16

400

15.0

381.0

121

36,237

205

61,565

15.6

396.8

131

39,315

223

66,794

20

500

18.8

477.8

190

56,996

323

96,832

19.6

496.9

205

61,643

349

104,729

The ranges apply only to compressed air and nitrogen. Contact us for other gases. The field accuracy of an insertion probe is typically +/- 5% due to installation conditions. Insertion probes may not be used for official compressor testing.

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS


FLOWSCOPE | VPINSTRUMENTS

‘The FlowScope enables us to perform air audits quicker, easier and more cost effective. It is the Swiss army knife for any compres­sed air auditor’ - Air Energy Management, UK

© 2014 VPINSTRUMENTS

15


VPFlowScope dP The VPFlowScope dP is designed for wet air1. When properly applied, it can be used in the discharge of the compressor. The VPFlowScope dP is fully compatible with the standard VPFlowScope, which means that it is easy to install and operate without additional training.

Typical applications

FlowScope dP > Extreme resistance to pollution and water drops > Mass Flow, Pressure & Temperature > Display/data logger module for easy recording of data

> Wet air, untreated compressed air1 > High temperature up to 150 °C (302 °F) > High velocity applications (undersized pipes)

1 The VPFlowScope dP can be used up to a high water content (saturated air). However, as it’s based on the Pitot principle, some limitations apply: The rangeability is smaller, no vertical lines, no overflooding with water. See user manual for details. CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


FLOWSCOPE DP | VP INSTRUMENTS

17

Specifications VPFlow Scope dP Flow sensor Measuring principle Flow range Accuracy Reference conditions Gases

Differential pressure 20 ... 200 mn/sec | 65 ... 650 sfps Bi-directional measurement 2% of reading over 1:10 range, under calibration conditions; Please refer to the user’s manual for details. Recommended pipe diameter: 50 mm (2 inch) and up. 0 °C, 1013.25 mbar | 32 °F, 14.65 psi Wet compressed air, Dry compressed air, Nitrogen and Inert gases.

Pressure sensor Pressure sensor range Accuracy

0 ... 16 bar | 0 ... 232 psi gage +/- 1.5% FSS Temperature compensated

Temperature sensor Temperature sensor range Accuracy

-40 ... +150 °C | -40 ... +302 °F. Icing should be avoided +/- 1 °C | 1.8 °F

Data outputs Digital Analog

RS485, MODBUS RTU protocol 4 ... 20 mA output, selectable via software to indicate flow, pressure or temperature

Display/data logger Technology Back light Data logger

Liquid Crystal (LCD) Blue, with auto power save 500,000 points

Mechanical & environmental Probe lengths Process connection Pressure rating Protection grade Ambient temperature range Wetted materials Corrosion resistance

400 mm | 15 inch (other lengths on request) Compression fitting, 0,5 inch PN20, higher pressure on request IP52 | NEMA 12 when mated to display module IP63 | NEMA 4 when mated to connector cap - do not mount upside down -10 ... +50 °C | 14 ... 122 °F. Avoid direct sunlight or radiant heat Higher ambient temperatures: consult factory Anodized Aluminum, Stainless steel 316, Epoxy Highly corrosive or acid environments should be avoided

Electrical Connection type Power supply Power consumption UL/ CUL CE

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS

M12, 5 pin connector, female 12 ... 24 VDC +/- 10 % Class 2 (UL) 1 Watt +/- 10% 50 mA +/- 10% @24VDC, constant over the entire flow range 14 AZ, Industrial Control Equipment EN 61326-1, EN 50082-1


FLOWSCOPE DP | VP INSTRUMENTS

18

Technical drawings

2 45

15 386

21 527

Or der codes Flow meters VPS.R200.P4DP.KIT VPFlowScope dP start kit, for air audits, complete with software VPS.R200.P4DP.D1 VPFlowScope dP with data logger display module, for auditors and permanent installation (stand-alone) VPS.R200.P4DP.D2 VPFlowScope dP with connector cap. For Modbus networks

Other probe lengths The standard P400 probe is acceptable for most air audits and installations. We offer P300 and P600 probes on request.

Material : Drawing nr. : Debur and break sharp edges Accessories FinishCable, : Unless VPA.5000.005 otherwise specified M12, 5 pole, for permanent connection dimensions are in VPA.5001.105 Interface box JB5 with 5 m/ 16.4 ft cable + 12 VDC power: supply Name millimeters VPA.5001.900 Connector cap with M12 socket for VPFlowScope sensor module Tolerances : Approvals Linear : NEN-ISO 2768-1-m ENG QA PROD Other :NEN-ISO 2768-2-K Further info acc. to : Scale : 1:10 Drawn: "Toleranties VPInstruments NEN ISO 2768" Date : SHEET 1 OF 1 VPS.R200.P4DP flow range table

VPS.R200.P4DP

All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copy S chedu le 4 0 Stan d a rd S e aml e ss Carb on S te e l P ip e

Schedule 10 Standard Seamless Carbon Steel Pipe

Size (inch)

DN

ID (inch)

ID (mm)

Min flow (scfm)

Max flow (scfm)

(m3n/hr)

Min flow

Max flow

2

50

2.1

52.5

92

917

156

1,559

(m3n/hr)

ID (inch)

ID (mm)

Min flow (scfm)

Max flow (scfm)

(m3n/hr)

Min flow

Max flow

2.2

54.8

100

999

170

1,697

(m3n/hr)

3

80

3.1

77.9

202

2,021

343

3,434

3.3

82.8

228

2,282

388

3,877

4

100

4.0

102.3

348

3,481

591

5,913

4.3

108.2

390

3,897

662

6,621

6

150

6.1

154.1

790

7,899

1,342

13,420

6.4

161.5

868

8,678

1,474

14,743

8

200

8.0

202.7

1,368

13,678

2,324

23,238

8.3

211.6

1,490

14,897

2,531

25,309

10

250

10.2

259.1

2,234

22,341

3,796

37,957

10.4

264.7

2,332

23,316

3,961

39,612

12

300

11.9

303.2

3,060

30,604

5,199

51,994

12.4

314.7

3,296

32,965

5,601

56,006

16

400

15.0

381.0

4,832

48,316

8,209

82,087

15.6

396.8

5,242

52,420

8,906

89,058

20

500

18.8

477.8

7,599

75,994

12,911

129,110

19.6

496.9

8,219

82,191

13,964

139,638

The ranges apply only to compressed air and nitrogen. Contact us for other gases. The field accuracy of an insertion probe is typically +/- 5% due to installation conditions. Insertion probes may not be used for official compressor testing.

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS


FLOWSCOPE DP | VP INSTRUMENTS

‘With the FlowScope dP, there is no more room for assumption.’

© 2014 VPINSTRUMENTS

19


20

Introduction | VPINSTRUMENTS

Get the complete picture! Measure, monitor and manage your compressed air system to reduce your energy consumption. Our flow meters are used to establish baseline air flows and energy use. VPVision warehouses and analyzes flow data. It becomes the cornerstone of an energy management system for any plant seeking to sustain the energy efficiencies they have achieved.

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS


21

Introduction | VPINSTRUMENTS

Monitor efficiency No more assumptions: We offer total solutions for monitoring the efficiency of your compressors.

Measure energy loss Monitor your pressure loss over the entire air treatment and take timely action.

Get a grip on quality Monitor dew point to check the performance of your air dryer. Make sure that the air quality meets your standards.

Monitor demand side

Drawing not to scale.

Use VPVision to check where, when and how much air is being used, and allocate costs.

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS


VPFlowScope® In-line With the three-in one VPFlowScope® in-line, VPInstruments sets the new standard for compressed air measurement. Flow, Pressure and Temperature measured at the same point with a single instrument makes measuring child’s play. All key performance indicators of your compressed air system are finally measured together, like it should be. It’s time to reveal and unleash the real savings potential of your factory.

FlowScope® in-line > Flow > Pressure > Temperature > Bi-directional option > 2M point data logger

The VPFlowScope® in-line is your best choice when you need to move forward in creating better efficiency levels in your compressed air and technical gas systems. Now you have an instrument that provides you with flow, pressure and temperature measurement in one single device, for point of use applications. Again, the VPFlowScope® in-line shows you when, where and how much you can save. The improvements of the VPFlowScope® in-line complete the product family and it is just as easily integratable as the VPFlowScope® probe.

General applications > Point of use measurement > Cost allocation > Sub metering of compressed air > Ring networks (bi-directional) > Leakage monitoring > Consumption metering of Nitrogen, Carbon Dioxide, Argon, Helium or any other dry, non-corrosive and inert gas.

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


FLOWSCOPE | VPINSTRUMENTS

23

Specifications - Thermal VPFlowScope® in-line Flow Sensor Measuring principle

Thermabridge mass flow sensor

Range and diameter

Flow (SI)

VPS.R080.M050 VPS.R250.M100 VPS.R01K.M200 Reference conditions Gases

0.32 ... 80 (m n/hr) 0.13 ... 50 SCFM 0.2 ... 150 SCFM 0.91 ... 250 (m3n/hr) 2.15 ... 600 SCFM 3.55 ... 1000 (m3n/hr) 0º C, 1013.25 mbar | 32º F, 14.65 psi Compressed air, Nitrogen and inert, non condensing gases

Flow (IM)

Size 0.5 inch 1 inch 2 inch

3

Sensors Range (SI) Range (IM) Flow Accuracy Pressure Accuracy Temperature Accuracy

Thermabridge mass flow sensor 0,5% FSS with calibration report under calibration conditions with air 5% FSS without calibration report 0 ... 16 bar gauge 0 ... 250 psi gauge ± 1.5% FSS (0 ... 60°C) ± 1.5% FSS (32 ... 140°F) 0 ... 60º C 32 ... 140º F ± 1° (from 10 mn/sec and up) (At zero flow conditions, temperature reading increases due to self-heating by the flow sensor)

Display Features Technology Memory (optional)

LCD, 3 line display 2 million points data logger

Data outputs Analog Serial IO USB

4 .. 20 mA or pulse, selectable via installation software Modbus RTU Mini USB interface for configuration (display version only)

Mechanical

Size

VPS.R080.M050 VPS.R250.M100 VPS.R01K.M200 IP grade Ambient temperature

135 mm x 49 mm x 85 mm | 5.31" x 1.93" x 3.35" 0.7 Kg | 1.54 lbs 135 mm x 54 mm x 91 mm | 5.31" x 2.12" x 3.58" 0.7 Kg | 1.54 lbs 150 mm x 88 mm x 124 mm | 5.9" x 3.46" x 4.88" 1.6 Kg | 3.53 lbs IP65 | NEMA 4 when mated to connector, at room temperature; direct rain and sunlight should be avoided. Extreme temperature fluctuations may affect the IP grade over time. 0 ... 60º C | 32 ... 140º F

Total length with pipes

Length

Pipe weight

0.5" 1" 2"

304 mm | 12" 501 mm | 19.7" 750 mm | 29.5"

0.3 Kg | 0.66 lbs 1.0 Kg | 2.20 lbs 3.2 Kg | 7.04 lbs

Weight

Electrical Connection type Power supply CE

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS

M12, 5 pin connector, female, and optional USB mini connector 12 ... 24 VDC ± 10% CLASS 2 EN 61326-1(2006) Class A, EN61000-6-1 (2007)


24

FLOWSCOPE | VPINSTRUMENTS

Smart, simple and complete. The VPFlowScope® in-line provides not just one, but all required parameters: flow pressure and temperature are measured at the same time, at the same point. It also features an optional built-in 2 Million point data logger. This means: no more hassle with external loggers, just plug in, press record and go! Crystal clear display 2 Million point data logger Thermabridge™ flow sensor Pressure sensor Temperature sensor RS485 Modbus RTU 4 ... 20 mA Pulse USB interface

Or der codes

Flow Range Option Display Option Connector

VPS.R080.M050 VPS.R250.M100 VPS.R01K.M200

0.32 ... 80 (m3n/hr) D0 0.91 ... 250 (m3n/hr) D10 3.55 ... 1000 (m3n/hr) D11

no display

C5

Display

C8 8 pin M12, for remote display*

5 pin M12

Display + 2 M point logger

* Only available for VPFlowScope in-line D0

Basic Features Display features Connector types Thermabridge Flow sensor

3 Line display

M12, 5 pin for standard application

Pressure and temperature sensor

Multi-session datalogger

M12, 8 pin for remote display function

4..20 mA or Pulse output (switchable)

Keypad for configuration

RS485 Modbus RTU

USB Cable included* *not available for VPFlowScope D0

Calibration options VPA.0009.001

ISO Calibration report ± 0,5 % FSS

VPA.5000.911

Bi-directional measurement option

Tubing kits VPA.1200.005

0,5 inch, in- and outlet tubes

VPA.1200.010

1 inch, in- and outlet tubes

VPA.1200.020

2 inch, in- and outlet tubes

Accesories D0, D10 and 11 version VPA.5000.005

Cable, 5m / 16.4 ft with M12 5pin connector on one side, open wires on other side.

VPA.5000.010

Cable, 10m / 32.9 ft with M12 5pin connector on one side, open wires on other side.

VPA.0000.200

Power supply (12V, 5pin, VPFlowScope)

Accesories D0 version only VPA.5001.205

Interface box JB5 with 5m/16.4 ft cable

+ 12 VDC power supply, includes USB converter

VPStudio software SFT.5003.300

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS

Licensed edition VPS&VPT


SENSORS | VPINSTRUMENTS

25

Dew point sensors Maintaining the dew point of your air or gas system will prolong the lifetime of your equipment. Permanent monitoring enables you to detect and prevent problems on time.

Product highlights

VPInstruments’ dew point transmitters are designed for ease of use, incorporating all the features needed to make installation and operation as simple as possible. The calibrated transmitters can be instantly incorporated into VPVision, or they can be connected to your air or gas management and control system.

> 2-wire loop powered connection > Dew point or ppm moisture content > IP66 (NEMA 4X) > Excellent sensor protection > Fast response time

App licatio n

DEW PO INT

Connection

ORDER CODEs

extreme dry air moderate dry air

-100 ... +20°C | -148 ... 68°F -40 ... +60°C | -40 ...140 °F

4 ... 20 mA 2 wire 4 ... 20 mA 3 wire

VPA.8000.1003 VPA.8000.1013

Spe cif ications VPA.8000.1003 VPA.8000.1013 Performance Measurement range Accuracy (dew point): Response time

-100 ... +20°C | -148 ... 68 °F dew point -40 ... +60°C | -40 ... 140 °F dew point ±2°C | ±3.6 °F dew point ±2°C | ±3.6 °F dew point 5 mins to T95 (dry to wet) <10 sec typical (90% of the step change)

Electrical output/input Output signal Supply voltage Current consumption Supply voltage influence

4 ... 20 mA (2-wire) current source, configurable over the entire range 12-28VDC 20mA max ±0.005% RH/V

4 ... 20mA (3-wire)

0 ... 100% RH -40 ... +60°C | -40 ... 140 °F 450 barg max. Temperature compensated across operating temperature range

0 ... 95% RH (non-condensing) -30 ... +70°C | -22 ... + 158 °F 20 barg maximum ±0.05 %/°C

IP65 | NEMA 4 Stainless steel L=132mm x ø27mm | 5,2 x 1,1" HDPE Guard <10 μm 5/8" - 18 UNF DIN connector

IP65 | NEMA 4 Nickel-coated brass L=85mm, ø24mm (max) | 3,3 x 0,9" HDPE front filter G1/2 (1/2" BSP) 2 m | 6.5 Feet

8-30VDC 9mA + load current ±0.005 % RH/V

Operating conditions Operating humidity Operating temperature Operating pressure Temperature coefficient

Mechanical specifications Ingress protection Housing material Dimensions Filter Process connection Connection

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


26

SENSORS | VPINSTRUMENTS

Current sensors The VPLog-i measures AC currents up to 3200A (true-RMS on a single phase power cable). The VPLog-i is very easy to use: just wrap around one of the three phases and close the snap fitting. It offers the best solution for your mobile power measurements. The VPLog-i is the only sensor on the market that offers both 4 ... 20mA and pulse outputs.

Product highlights

Outputs

> > > > >

4 ... 20mA: The analogue output is proportional to the measured input and ranges from 4 to 20mA. Pulse: The pulse output generates a pulse frequency proportional to the current measured. This allows that the VPLog-i can be used as a simple power meter.

Very easy and quick installation Plug and play For fixed and mobile measurements Both 4 ... 20mA and pulse output Loop powered

Usage

Application examples:

Easy does it: Just open the sensor and wrap around the power cable you want to measure. The LED on the device blinks when the VPLog-i is powered. The rate at which it blinks is proportional to the output current. You can use one of the two outputs to get accurate measurement results.

> Power consumption of compressors > General purpose power measurement > Electricity sub metering The current sensor measures the input power of your compressor’s electric motor. When combined with a flow meter, it can be used to determine the actual efficiency of the compressor.

Specifications Accuracy +/- 1% full scale. Power supply 6 ... 30 Vdc Power consumption 4 ... 20mA Current input 100 ... 3200 A-rms (50Hz current) Max Voltage Insulated cables only! On open bus bars max 300 Volt Pulse rate 0 ... 2.66 Hz Coil length 170 mm | 6.7", 250 mm | 9.8", 350 mm | 13.8" Coil diameter 7 mm | 0.28" Coil bend radius 35 mm | 1.38" Housing W x H x D 26.7 x 41.4 x 13.6 mm | 1.1 x 1.6 x 0.6 inch Operation temperature range -20 ... 70°C | -4 ... 158 °F Operational relative humidity Max 95%, non condensing

Or der cod e s

CAT-VP-1409-WO

M a x c u rre n t - rms

F r eq uen c y

P uls e s / A h

C o i l len g t h ( mm)

in c h

VPA.8000.2100

100 A

10

170

6.7

VPA.8000.2200

200 A

10

170

6.7

VPA.8000.2400

400 A

VPA.8000.21K5

1500 A

© 2014 VPINSTRUMENTS

50/60 Hz

10

170

6.7

1

250

9.84


Monitor ‘If you monitor, you know when, where and how much you can save’

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


28

FLOWterminal | VPINSTRUMENTS

VPFlowTerminal The VPFlowTerminal is a plug & play wall mount display with built-in power supply and 2 million point data logger. The VPFlowTerminal has five sensor inputs: one input for a VPFlowMate or VPFlowScope mass flow meter, and four generic analog inputs and can record up to 8 channels. This makes the collection and analysis of your compressed air data easier and quicker!

Product highlights > 2 Million data points > VPFlowMate / VPFlowScope input > 4 analog input channels

Applications Efficiency: monitoring the efficiency of your compressor system. Measure with the VPFlowScope in the main pipe line of your system and measure with 4 power meters the power consumption of each compressor. Air audits: the VPFlowTerminal can be used for air audits since you collect all data within one data logger. This makes the data collection, read out and analysis very convenient. Total package: Measure flow together with dew point, pressure and power consumption.

Or der codes For VPFlowTerminal VPT.5110.000 VPFlowTerminal for VPFlowScope. Including display with built-in data logger. Pre-mounted connector for VPFlowScope. Built-in power supply. Includes Blac cap and 5 M / 33" for cable VPT.5000.001 (option) 4 Analogue inputs for VPFlowTerminal. Data will be logged simultaneously. Configuration and read out with VPStudio.

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS


FLOWterminal | VPINSTRUMENTS

29

Technical drawings 1

2

3

4

5

6

VPT.5110.00X A

5.1 130

A

B

B

2.8 70

C

8.7 220

Material : Debur and break sharp edges Finish : Unless otherwise specified dimensions are in millimeters Tolerances : Linear : NEN-ISO 2768-1-m ENG Other :NEN-ISO 2768-2-K Further info acc. to : "Toleranties VPInstruments NEN ISO 2768"

D

Break sharp edges 1

2

C

Drawing nr. :

VPT.5110.00X.

Approvals QA

Name : PROD

VPFlowTerminal

Drawn:

Scale : 1:5

Date :

SHEET 1 OF 1

A4

All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner.

Specifications VPFlowTerminal Input voltage Housing type Display Back light Data logger Signal inputs Sensor power supply Maximum sensor current Data outputs Ethernet interface Basic configuration Flow meter connection Additional connections Dimensions Weight

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS

100 ... 240 Vac mains (pre-wired) Painted Aluminum IP65 | NEMA 4 Liquid Crystal (LCD), 3 lines Blue with auto power save. 2.000.000 points. VPFlowScope + 4 optional 4 ... 20 mA sensors (non - isolated, loop powered) 24 VDC 4 x 25 mA for analog sensors, 1 x 150 mA for VPFlowScope USB for configuration and data retrieval Modbus / TCP port Via key pad M12, 8 pin Cable glands for analog inputs, Ethernet connection. l x b x h = 230 x 130 x 75 mm. | 9.1 x 5.1 x 2.95" 1.6 kG | 3.53 Lbs


30

STUDIO | VPINSTRUMENTS

VPStudio Software With VPStudio, you can configure all VPInstruments products, view real time measurements and retrieve data log sessions. VPStudio enables you to view data in any unit both SI and Imperial. You can schedule your data log session, set logging intervals and adjust flow meter parameters. VPStudio communicates via your PC’s USB port.

Applications > As configuration tool for all VPInstruments products > To read saved data log sessions > To extract recorded data to CSV files > Optional real time data logging on PC which can be saved as CSV

F u nctions

f re e e d i t i o n 1

a d van c ed V P F lo w M a t e

a d van c e d V P F lo w S c o p e

f ull/ e valuat ion 2

Order codes SFT.5003.200 SFT.5003.300 SFT.5003.400 Flowmeter configuration √ √ √ √ (all types) Download data log sessions √ √ √ √ Data Export √ √ √ √ Real Time measurement √ √ VPFlowScope/VPFlowTerminal Real time measurement √ √ VPFlowMate Scheduler for display/ √ √ VPFlowTerminal CSV Studio √ √ √ 1 2

CAT-VP-1409-WO

Free edition: basic configuration only Evaluation version is valid for one month from date of activation

© 2014 VPINSTRUMENTS


Manage ‘Beware of little expenses; a small leak will sink a great ship’ - Ben Franklin

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


32

VISION | VPINSTRUMENTS

VPVision VPVision offers you the complete monitoring solution for compressed air and technical gases. It makes energy savings easy, quick, and rewarding. Using the latest web technology, VPVision enables you to view data anywhere, anytime. VPVision analyzes flow data and makes your savings potential transparent. VPVision can be expanded to receive and consolidate data such as electric demand (compressor kW) and dew point. VPVision can also be fully integrated into a plant’s existing SCADA system and linked to the Internet to allow access by designated company staff from anywhere.

Project approach Although VPVision is a very user friendly software solution, preparation is key to a successful implementation. No compressed air system is the same. Therefore each VPVision system is customized to your needs and goals. Your return on investment can be a matter of months. With our VPVision project form, we can calculate the required investment and ROI. Ask your local distributor or go to our website for details.

With VPVision you can: > Maintain your efficiency > Allocate costs > Track and monitor leak level > Generate automated reports in PDF > Expand and adapt the system > Follow your system via IPad®, Smart PH, tablet and web browser > Centralize benchmark different plants on different locations. > Track Maintenance need points

Product highlights > Web based interface > Built in report tools > Early alert on leakage. > Direct insight in costs > Based on standardized hardware

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


33

VISION | VPINSTRUMENTS

VPVision project examples Food production In a Kikkoman soy sauce factory, a VPVision system has been installed to monitor the demand side of the compressed air system. All individual cost centers are monitored by a flow meter. VPVision logs all data and provides real-time feedback on actual use.

Cookie factory Bolletje, a Dutch manufacturer of cookies and bakery products invested in a VPVision system to allocate costs to various production lines. The system is linked to 3rd party energy monitoring and reporting software. VPVision was part of a compressed air optimization project, which resulted in a cost reduction of 25%.

Steel factory In a large steel plant, VPVision is used to monitor 10 compressor stations. It guards a savings program which exceeds 250,000 Euro/ 300,000 USD per annum, and helps to make the right decision on where to save next.

Metal parts production Astrum, a leading manufacturer of casted steel parts in the UK invested in a VPVision system to monitor the overall compressed air supply and demand. The VPVision system is part of a complete compressed air system re-design, with an ROI of less than 3 years.

Goal

Continuous improvement of energy efficiency

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS

Flow data Pressure data Temperature data Power consumption Other relevant data


34

VISION | VPINSTRUMENTS

Part numbers overview The following table provides an overview of the available hardware and software. Please use the project preparation form, which can be supplied by your local distributor. This form is used to determine the complete list of required hardware and software for your project.

Or der codes VPV.6001.M00 VPVision M. Main unit, with VPVision software, database, webserver, built-in power supply pre configured to display up to 8 VPFlowScope sensors. Can be read out on your own PDA, Tablet, PC or touch screen via the network. Powder coated steel enclosure, IP65. VPV.HMI2.010 10" Panel mount touchscreen. VPA.5030.020 Modbus junction box (IP65.) Add one per VPFlowScope for a Modbus RS485 multidrop network. VPA.5030.011 Modbus extension module with power supply. Din rail mounted power supply module built into IP65 plastic enclosure. With this module you can suppy power to another 8 VPFlowScopes in a daisy chain. VPA.5030.111 Power supply module with Ethernet converter for 8 additional VPFlowScope sensors. Built in IP65 plastic enclosure. With this converter you can transfer Modbus signals over Ethernet to the VPVision M unit, or an existing building management system. VPA.5030.211 Analogue to Ethernet converter with power supply. Power supply module with 4..20 mA analogue inputs. Built in IP65 plastic enclosure. With this converter you can transfer analogue signals over Ethernet to the VPVision M unit or an existing building management system. VPA.5030.311 Analogue and Modbus to Ethernet converter with power supply. Power supply module with an analogue and a Modbus converter, to combine analog sensors with up to 8 VPFlowScope sensors. Built in IP65 plastic enclosure. With this converter you can transfer Analogue and Modbus signals over Ethernet to the VPVision M unit or an existing building management system. SFT.6001.M01 Additional measurement points implemented in the software. The software is designed to display up to 8 flow meters in a convenient way. Above 8, channels are grouped together. Ask us for a project specific quotation in this case. SFT.6001.M05 Additional visualiation P&ID : overview of your compressed air system SFT.6001.M07 Alarms module. With the alarm module, you can pre-set trigger levels, and e-mail an alarm message when the signals are out of bounds. The ideal tool for maintenance management and leakage alerts. Contact your local dealer for Job Sizing Template.

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS


Install ‘It all begins with proper installation’

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


TOOLS & ACCESSOIRES | VPINSTRUMENTS

36

Hot tap drill The hot tap drill is the universal tool to install your insertion flow meter in any compressed air system. In only 30 minutes you can drill a hole and install your flow meter. Using a hot tap saddle and a hot tap drill, you can create a new installation point without depressurizing your installation. Compared to low-cost electrical hot tap drills, which are prone to jamming and breaking of the drill head, our hot tap drill is safe and easy to operate. See our instruction video for details.

Sp ecifications

Note: Hot tapping is a skilled task. Familiarize yourself with this task. VPInstruments also offers you training to become skilled. Once trained, you will be able to make process connections quickly, safe and economically. The average time to install is only 30 minutes.

VPA.8001.1002 Max pressure 10 bar | 145 psi, higher pressure ratings on request Drill shaft diameter 16 mm | 0.6 inch Drill shaft length 345 mm | 14 inch Drill diameter 17 mm x M10 | 0.7 inch x M10

Features: > For application up to 10 bar > 1" Hot tap drill size > All accessories included > ExplorerÂŽ transport case included

Benefits: > Make an installation point without taking the pressure of your system. > Hand operated: no power tool needed on-site > Safe and easy operaion > Versatile: For stainless and carbon steel

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS


TOOLS & ACCESSOIRES | VPINSTRUMENTS

37

Thickness gauge The ultrasonic thickness gauge is used to measure wall thickness, which is key information to calculate the exact inner pipe diameter. It is important to know the exact wall thickness, especially in smaller pipes. In the table below, we show the influence of 1 mm | 0.04 inch error on your flow meter reading, for various pipe diameters.

Features: > Capable of performing measurements on a wide range of materials, including metals, plastic, ceramics, and glass. > High accuracy. > Integrated data logger. > One universal probe for a wide measuring range. > Includes transport case. Disclaimer: The VP Thickness Gauge is only to be used to give an idea of wall thickness and not integrity or composition of the material.

Diam e t er ( mm)

~i n c h

Error (%)

50

2

4

100

4

2

150

6

1.30

200

8

1

250

10

0.80

300

12

0.70

Sp ecifications VPA.8001.1001 Measuring range (steel) Accuracy Working temperature Display Connections Power supply Operating time Data logger Protection class Device Probe Software

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS

0.6 ... 400 mm | 0.02 ... 16 inch (depending on probe type) 0.1 mm | 4/1000" -10 ... 50°C | 14 ... 122 °F Back-lit display (128 x 64 pixel) USB, probe 2 x LR6 / AA - primary cell 40 hours (backlight off) Max. 10,000 readings IP65 | NEMA 4 IP67 | NEMA 6P Software included, Windows


TOOLS & ACCESSOIRES | VPINSTRUMENTS

38

Leak Detector The VP Leak Detector is a practical tool for any leak detection program. Simple to use - find compressed air leaks and prevent machinery failure with this unique instrument. Leak detectors are a beneficial addition to mass flow meters for your leakage management program. The two instruments together make your leakage management system efficient. Measure and manage your ROI when repairing leaks. Use your flow meters to establish a leakage level before you repair the leaks and report the savings after. The VP Leak Detector features a sensitivity dial with decibel indications. In addition, it features an LED bar graph display in which each LED equals approximately 3 dB - ideal for calculating decibel levels.

Application examples:

Or der codes

> Compressed Air Leak Detection > Pressure and Vacuum Leak Detection > Exhaust system leaks > Tanks, pipes, Leak testing > Electrical Inspection

VPA.8000.1010 Ultrasound leak detector basic VPA.8000.1011 Ultrasound leak detector start kit for air audits, with data logger

Sp e cifications Construction Hand-held ABS pistol type ultrasonic processor, stainless steel sensor enclosures Peak frequency response 36-44 kHz Indicator 10 segment LED Bar Graph (red) Power 9 Volt Alkaline Battery Low Battery Voltage Indicator LED Response time Response time: 300 msec Operating Temperature Range 0 ... 50 °C (32 °F ... 120 °F) Relative Humidity 10-95% non-condensing at up to 30 °C (86 °F) Dimensions 13.3 x 5 x 20.3 cm (5.25" x 2" x 8") Weight 0.3 kg (11 oz) Carrying Case Nylon soft carrying case

CAT-VP-1409-WO

© 2014 VPINSTRUMENTS


TOOLS & ACCESSOIRES | VPINSTRUMENTS

Savings tips 1. Shut off sections and machines that you do not use A simple manual or motorized valve can save you thousands of euros/dollars. Make sure that air is not lost through leaks or machines standing in idle mode. Flow meters help to determine to which sections air is flowing.

2. Breathe cool, fresh and clean air A compressor converts 90% of its power into heat. The compressor room heats up, while a compressor uses less energy to compress cold air. 3°C cooler air, already results in 1% energy savings.

3. Invest in an efficient control system Have insight in your compressed air usage profile, so you can optimize your compressor control system. Ask an air audit specialist to perform an air audit, and make an improvement plan based upon the results.

4. Think about the required air quality Clean compressed air is important for the life span of your compressed air installation. Choose the right quality carefully for specific processes whenever possible, as higher air quality results in higher energy costs.

5. Reduce offload hours Electricity consumption of a compressor in offload stage costs 10-35% of the consumption during load hours. At >80% use of the capacity, the offload-load control is considered efficient. Choose the right control system.

6. Manage your leakage In general there is 20-40% of leakage in a compressed air installation. VPVision can be used as a global leakage management system and helps you to rank the leaks on savings potential. Invest in an ultrasound leak detector to find the leaks.

7. Balance your system Is your compressor oversized? In some applications the compressor is bigger than necessary, for instance after changes in the production process. The payback time of the investment in a smaller compressor is often short.

8. Reduce the pressure Every bar pressure reduction gives an instant win of 7% on your energy consumption. Invest in pressure regulators per production area, use buffer vessels and reduce pressure swings in your network.

9. Think of alternative uses Compressed air is 8 times more expensive than electric power. However compressed air is often used, simply because it is present. The VPFlowScope offers insight in the usage and helps you to select the right solution.

10. Choose the right pipe size and material A proper pipe system is crucial to limit your pressure drop. Iron pipes tend to rust. Too small piping creates pressure loss. Use angular feed-ins on the main header to reduce pressure loss.

CAT-VP-1409-WO

Š 2014 VPINSTRUMENTS

39


Corporate Headquarters Van Putten Instruments BV Buitenwatersloot 335 2614 GS, Delft, The Netherlands T +3115 2131580 F +3115 2130669 Email: info@vpinstruments.com

Š 2012-2014 Van Putten Instruments. Subject to change without prior notice. All dimensions stated in drawings are indicative. For actual specifications, always consult factory. Our core intellectual property and brand names are protected by Dutch, US and international patents trademark rights, copyrights, and exclusive licenses. All artwork and 3D images in this catalog are copyright material and exclusively made for promotion of VPInstruments. Violators will be prosecuted to the maximum extent possible, by the respective owners. Nothing from this catalog may be re-printed or reused in any way without prior permission. Our general terms and conditions of sale apply on all sales transactions. A copy can be downloaded from our website.

US Marketing & Sales office T +1 740-862-0084 Email: sales@vpinstruments.us US service center T +1 907-301-0530

VPinstruments only sell and distributes through authorized dealers Your local dealer:

www.vpinstruments.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.