Mitsubishi GOT1000

Page 1

Mitsubishi Graphic Operation Terminal Simply the best

G R A P H I C O P E R A T I O N

It's not a mere display. It's a GOT.

T E R M I N A L G O T 1 0 0 0 Mitsubishi Electric Corporation Nagoya Works and Himeji Works are factories certified for ISO14001 (standards for environmental management systems) and ISO9001 (standards for quality assurance management systems).

http://MitsubishiElectric.co.jp/melfansweb/english/


INDEX

It's what we do. Coming up with answers. Breaking new ground. And now it's here-the GOT1000-reflecting the next generation's vision. Its beauty alone, its functionality alone, takes the GOT1000 beyond a mere "display". But what really sets

it apart is the usability that was inspired by voices from actual worksites.

How far can a display evolve when functions are inspired by the voices of actual users, rather than a race for that "new To answer this question, Mitsubishi drew on its technology and experience cultivated at actual FA worksites, and In addition to raising the level of display basics such as response, display, and connectivity, the GOT1000 is packed with In short, the GOT1000 is about usability, and creating new value. The GOT1000 not only gives customers improved connectivity to PLCs and a host of other FA devices, it provides a

look"?

Concept Lineup Features

2

For designers For operators For intial startup & adjustment operators For maintenance personnel Handy GOT

8 19 20 22 26

Connectable model list Connection configuration Bus connection Specification External dimensions Function list for each model Notes for use List of products

28

4

the resulting GOT1000 sets the standard for the next generation. ideas and functions designed to improve productivity and workability. powerful competitive edge in the global market as well.

Toward

a

unique

GOT

brand

The needs expressed by users will continue to be a central part of the GOT series evolution to the next-generation display. Mitsubishi Electric's aims are summed up by the slogan, "Simply the best!". Simply the best

32 38 48 50 52 54 56


Full-spec models accommodate a wide range of applications in stand-alone or network environments

GT15

15'' TFT (High-brightness, wide viewing angle) Type GT1595-XTBA (AC type)

An innovative and highly perfected platform sets the GOT1000 Series in a class all by itself

Throughout our pursuit to deliver a solution that meets the needs of the industry, we developed an innovative platform based on performance, technology and design - the GOT1000 Series. This development concept is shared across the "Basic" (GT11 Series) and "Advanced" models (GT15 Series) to offer a wide range of flexible panel mount and pendant style solutions.

Type

Resolution: XGA 1024 x 768 Display colors: 256 colors/65536 colors*1

TFT (High-brightness, wide viewing angle) GT1585-STBA (AC type) GT1585-STBD (DC type)

Ethernet download

Human sensor

Gateway

65536 colors

Human sensor

Ethernet download

Gateway

Ethernet download

256 colors

Gateway

Multi channel

65536 colors

256 colors

Ethernet download

Gateway

Multi channel

Intelligent unit monitor

Transparent

System monitor

A/FX list editor

Ladder monitor

Intelligent unit monitor

Q motion monitor

Servo amplifier monitor

Network monitor

A/FX list editor

Ladder monitor

Multi channel

Transparent

System monitor

A/FX list editor

Ladder monitor

Transparent

System monitor

A/FX list editor

Ladder monitor

Intelligent unit monitor

Q motion monitor

Servo amplifier monitor

Network monitor

CNC monitor

Intelligent unit monitor

Q motion monitor

Servo amplifier monitor

Network monitor

CNC monitor

Q motion monitor

Servo amplifier monitor

Network monitor

CNC monitor

CF card I/F

Standard interface, standard memory size USB

Memory 9MB

8.4'' Type

USB

Computer link

MELSECNET/10

CC-Link

Computer link

MELSECNET/10

CC-Link

Ethernet

TFT (High-brightness, wide viewing angle) GT1565-VTBA (AC type) GT1565-VTBD (DC type)

10.4'' Type

Resolution: VGA 640 x 480 Display colors: 256 colors/65536 colors*1

Standard interface, standard memory size USB

Memory 9MB

RS-232

Computer link

MELSECNET/10

CC-Link

10.4''

GT1575-VNBA (AC type) GT1575-VNBD (DC type)

Type

Resolution: VGA 640 x 480 Display colors: 256 colors

Direct CPU connection

Bus

Ethernet

TFT

Memory 9MB

Computer link

MELSECNET/10

Connection format*3

Direct CPU connection

Bus

CF card I/F

*2

Connection format*3

Direct CPU connection

Bus

CF card I/F

RS-232

*2

Connection format*3

Direct CPU connection

Ethernet

Drawing, computing, communication A triad of high-speed response

Standard interface, standard memory size Memory 9MB

*2

Connection format*3 Bus

CF card I/F

RS-232

GT1575-VTBA (AC type) GT1575-VTBD (DC type)

Features

65536 colors

System monitor

RS-232

TFT (High-brightness, wide viewing angle)

Resolution: VGA 640 x 480 Display colors: 256 colors/65536 colors*1

Features 256 colors

*2

mDrawing...Equipped with a high-speed drawing chip (GT15 only) mComputing...Offers high-speed computing performance mCommunication...Bus connection (GT15 only) and RS-232 communication (max. 115.2kbps)

Type

Transparent

Standard interface, standard memory size

10.4''

GT1575-STBA (AC type) GT1575-STBD (DC type)

Multi channel

USB

GOT1000 common features

TFT (High-brightness, wide viewing angle)

Resolution: SVGA 800 x 600 Display colors: 256 colors/65536 colors*1

Features 256 colors

10.4'' Type

Resolution: SVGA 800 x 600 Display colors: 256 colors/65536 colors*1

Features 65536 colors

12.1''

CC-Link

Ethernet

TFT

8.4''

GT1572-VNBA (AC type) GT1572-VNBD (DC type)

Type

Resolution: VGA 640 x 480 Display colors: 16 colors

TFT GT1562-VNBA (AC type) GT1562-VNBD (DC type)

Resolution: VGA 640 x 480 Display colors: 16 colors

Beautiful and expressive screen m65536 Full color (GT15) mMonochrome 16 gray scales (GT11) mGreatly increased memory capacity Features

USB interface Standard item & front-mounted mUp to 20 times faster data transmission than previous models mFront-mounted USB interface allows fast data exchange

Features

65536 colors

256 colors

Ethernet download

Gateway

Multi channel

Transparent

System monitor

A/FX list editor

Ladder monitor

Intelligent unit monitor

Q motion monitor

Servo amplifier monitor

Network monitor

Standard interface, standard memory size USB

CF card I/F

RS-232

Gateway

Multi channel

Transparent

16 colors

Ethernet download

Gateway

Multi channel

Transparent

16 colors

Ethernet download

Gateway

Multi channel

Transparent

System monitor

A/FX list editor

Ladder monitor

Intelligent unit monitor

Q motion monitor

System monitor

A/FX list editor

Ladder monitor

Intelligent unit monitor

Q motion monitor

System monitor

A/FX list editor

Ladder monitor

Intelligent unit monitor

Q motion monitor

Servo amplifier monitor

Network monitor

Servo amplifier monitor

Network monitor

Servo amplifier monitor

Network monitor

USB

*2

Ethernet

Direct CPU connection

Features

Ethernet download

Standard interface, standard memory size Memory 9MB

CF card I/F

RS-232

Standard interface, standard memory size USB

Memory 5MB

MELSECNET/10

CC-Link

Bus Ethernet

Direct CPU connection

Standard interface, standard memory size USB

Memory 5MB

RS-232

*2

Connection format*3 Computer link

CF card I/F

RS-232

*2

Connection format*3 Bus

Features

256 colors

Connection format*3 Computer link

MELSECNET/10

CC-Link

Bus

Direct CPU connection

Memory 5MB

Computer link

MELSECNET/10

Connection format*3 Computer link

MELSECNET/10

CC-Link

Bus

Ethernet

*1: With high-resolution graphic board. *2: RS-422 communication is possible by installing an RS-422 conversion unit at the RS-232 interface. *3: Bus, MELSECNET/10, CC-Link, and Ethernet are compatible only with Mitsubishi PLCs.

CF card I/F

*2

Direct CPU connection

CC-Link

Ethernet

GT15

Functions bearing this mark are available only on GT15 series models. All other functions are supported by both the GT11 and GT15 series.


There's a model for your needs. All 19 models in the GOT1000 lineup offer the same user friendliness.

The GOT1000 Series flexibly adapts to systems comprising various models and brands of FA devices

5.7'' STN

STN

Type GT1150-QLBD (DC type)

GT1155-QSBD (DC type)

Resolution: QVGA 320 x 240 Display colors: 256 colors

Collect and organize information from various FA devices to display on a single screen for quick reference Multi-channel function*

Central storage of FA device information

Wide selection of connectable FA devices

Resolution: QVGA 320 x 240 Display colors: 16 gray scales

v The GOT1000 series has expanded the range of connectable devices, permitting connection to both Mitsubishi and other brand PLCs.

v The GT11 is equipped with high-speed RS-232 and RS-422 interfaces (standard items) which can be used in an alternating manner, thereby enabling multiple GOTs to be connected.

(10 brands, including Omron, Yokogawa Electric, etc.)

Newly compatible PLCs

v Internal clock function permits the use of alarm display and clock functions even when connected to a PLC which has no clock.*3

NEW

[Mitsubishi PLC] FX3U; [Other brand PLCs] KEYENCE: KV-700/1000; Matsushita Electric Works: FP-E; SIEMENS: SIMATIC S7-200 Series

Up to 4 simultaneous communication channels! v Monitoring of up to 4 channels of FA devices (PLCs, servo amplifiers, inverters, temperature controllers, etc.). v Monitoring of all FA devices on a single screen on the GOT. Easily designed monitor screens.

Before...

256 colors

Features Vertical display

Transparent

System monitor

A/FX list editor

CF card I/F

Memory 3MB

Standard interface, standard memory size USB

RS-232

RS-422

16 gray scales

Vertical display

Transparent

System monitor

A/FX list editor

RS-232

RS-422

CF card I/F

Memory 3MB

v The GT15 is equipped with a high-speed RS-232 interface as standard. Moreover, RS-422 communication is possible by installing an RS-422 conversion unit at the RS-232 interface.

Direct CPU connection

Direct CPU connection

CC-Link

Computer link

QJ71BR11

MODE RUN ERR USER BAT BOOT

Required temperature controller programs = Increased PLC load.

USB

Customers' needs

Required computer link unit for temperature controller connection = Increased cost.

QX10

QX41

QX41

QJ71BR11

POWER

QJ71C24-R2 MNG D.LINK RD ERR

PULL

RUN T.PASS SD ERR

MNG D.LINK RD ERR

0 1 2 3 4 5 6 7 8 9 A B C D E F

Requires no computer link unit for temperature controller connection = Reduces cost!

Easy monitoring of temperature controller data on GOT

Requires no programs for temperature

Temperature controller

controller =

Reduces PLC load!

m Examples of usage

Connection format

Computer link

QX41

0 1 2 3 4 5 6 7 8 9 A B C D E F

PULL

*1: No need to create screens to use the servo amplifier monitor function. For details on the servo amplifier monitor function, see the "Features and recommended points" on page 25. *2: Monitoring and writing of devices, which are equivalent to MELSEC-Q4A, are supported. CNC parameters can be specified by using the CNC monitor function. For details on the CNC monitor function, see the "Features and recommended points" on page 25. *3: GT15 requires an optional battery (GT15-BAT) in order to save clock data.

QX41

RUN T.PASS SD ERR

MODE RUN ERR USER BAT BOOT

USB

Mitsubishi CNC Connection format

QX10

POWER

PULL

Standard interface, standard memory size USB

Q25HCPU Q61P-A1

PULL

Q25HCPU

v Connection with Mitsubishi servo amplifiers is possible to monitor parameters on flexibly designed screens.*1

Features

With multi-channel functions...

Temperature controller Q61P-A1

v Also connectable to temperature controllers, and to Mitsubishi inverters and CNCs*2. N E W

Features and recommended points

Type

For designers

More design freedom through flexible connectivity

Standard models offer a full array of basic functions for stand-alone use

GT11

5.7''

For designers

Other brand PLCs

MELSEC + Temperature controllers + Inverters

MELSEC + MELSERVO

Ethernet CC-Link Q25HCPU

*1

Mitsubishi inverter

QX10

QX41

QX41

QJ71BR11

POWER

Q61P-A1

*1

RUN T.PASS SD ERR

MODE RUN ERR USER BAT BOOT

QJ71BR11 MNG D.LINK RD ERR

RUN T.PASS SD ERR

MNG D.LINK RD ERR

Q25HCPU

0 1 2 3 4 5 6 7 8 9 A B C D E F

PULL

USB

PULL

Q61P-A1

QX10

QX41

POWER MODE RUN ERR USER BAT BOOT

PULL

USB

PULL

QX41

QJ71BR11 RUN T.PASS SD ERR

QJ71BR11 MNG D.LINK RD ERR

RUN T.PASS SD ERR

MNG D.LINK RD ERR

0 1 2 3 4 5 6 7 8 9 A B C D E F

Brand "A" PLC A62P

A4UCPU

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

Temperature controller

AJ71BR11

Q25HCPU Q61P-A1

MODE RUN ERR USER BAT BOOT

USB

5.7'' Type

Mitsubishi servo amplifier

5.7'' Handy GOT/STN

Handy GOT/STN GT1155HS-QSBD (DC type)

coming soon

Resolution: QVGA 320 x 240 Display colors: 256 colors

Type GT1155HS-QSBD (DC type)

Inverter

Brand "B" PLC Easy data exchange between PLCs

coming soon

Resolution: QVGA 320 x 240 Display colors: 16 gray scales

QX10

QX41

POWER

PULL

PULL

QX41

QJ71BR11 RUN T.PASS SD ERR

RUN T.PASS SD ERR

IN

MODE RUN ERR USER BAT BOOT

PULL

USB

PULL

Up to 4 simultaneous communication channels

QX10

QX41

POWER

MNG D.LINK RD ERR

Stand-alone PLCs (FX, or other brand PLCs) + MELSECNET/10

Other brand temperature controller

Q25HCPU Q61P-A1

QJ71BR11 MNG D.LINK RD ERR

0 1 2 3 4 5 6 7 8 9 A B C D E F

RUN T.PASS SD ERR

MNG D.LINK RD ERR

Servo amplifiers (pulse train type)

GOT rear face

POWER RUN BATT.V PROG.E CPU.E IN

QJ71BR11 MNG D.LINK RD ERR

Example of communication unit combinations

10 11 12 13 14 15 16 17

FX2N-32MR

QJ71BR11

Central management of alarms and parameters

0 1 2 3 4 5 6 7

ESC

POW RUN

QX41

RUN T.PASS SD ERR

0 1 2 3 4 5 6 7 8 9 A B C D E F

Serial communication unit

0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17

BAT ERR LRUN LERR

OK

IN

0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17

POWER RUN BATT.V PROG.E CPU.E

MELSECNET/10

Brand "C" PLC

Q25HCPU

Q25HCPU Q61P-A1 POWER

Brand "B" PLC A62P

0 1 2 3 4 5 6 7 8 9 A B C D E F

MODE RUN ERR USER BAT BOOT

PULL

A4UCPU

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

QX10

QX41

QX41

POWER

AJ71BR11 USB

PULL

QJ71BR11 RUN T.PASS SD ERR

QJ71BR11 MNG D.LINK RD ERR

RUN T.PASS SD ERR

Q61P-A1

MNG D.LINK RD ERR

MODE RUN ERR USER BAT BOOT

PULL

USB

STOP

PULL

FX3UC-32MT-LT

Mitsubishi PLC

QX10

QX41

POWER

RUN

0 1 2 3 4 5 6 7 8 9 A B C D E F

QX41

QJ71BR11 RUN T.PASS SD ERR

FX2N-32MR

IN

0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17

RUN T.PASS SD ERR

MNG D.LINK RD ERR

Microcomputer, FX, other brand PLCs

Stand-alone devices can be connected to the network

Brand "A" PLC Features 256 colors

Transparent

System monitor

A/FX list editor

16 gray scales

Standard interface, standard memory size USB

RS-232

Computer link

System monitor

A/FX list editor

Memory 3MB

USB

RS-232

CF card I/F

RS-422

Direct CPU connection

CC-Link

Computer link

*: The number of channels and functions, which can be used with the multi-channel function, vary according to the connection configuration. For details, see the "Notes for use" on page 55.

Recipe

Bus communication unit

Alarm Logging

For wider GOT support of applications

Improved Microcomputer connection

Memory 3MB

v Expanded D-device support, with the following devices now

Connection format *1

*1: Via G4 (AJ65BT-G4-S3) only.

Transparent

Standard interface, standard memory size CF card I/F

RS-422

Connection format Direct CPU connection

For connectable FA devices, see the "Connectable model list" on page 28. For connection format specific features, see the "Connection configuration" section on page 32.

Features

Optional function board is required. GT15...GT15-QFNB(MM)

QJ71BR11 MNG D.LINK RD ERR

0 1 2 3 4 5 6 7 8 9 A B C D E F

supported: Bit devices: L, M, SM; Word devices: R, SD.

CC-Link

*1

v The number of interruption points has been increased from 1 byte to a maximum of 4 bytes, enabling simpler control program design. v The GOT1000 series has an internal clock function which can be used for alarm displays and clock functions.*

Functions with this mark are newly supported by the GT11 series, not only by the GT15 series.

v Offers wider communication protocol support (15 types). • Mitsubishi A/QnA/Q-computer link unit (8 types) • GOT-A900 series compatibility (2 types) • GOT-F900 series compatibility (2 types) • Digital Electronics (Proface) memory link format (3 types)

Inverter Barcord Reader

MELSEC PLC Servo

*: GT15 requires an optional battery (GT15-BAT) in order to save clock data.

8

9


For designers

For designers

Lead the way in information sharing between the office and worksite

For greater freedom in creating beautiful screens that best suit your needs Draw without memory capacity worries

Be alerted to worksite errors and collect worksite controller data from an office desk

Vastly increased memory capacity

2 Monitor other GOTs from a GOT

GT15MM-MTBM: Standard 9MB memory (optional expansion up to 57MB) GT15MM-VNBM N E W : Standard 5MB memory (optional expansion up to 53MB)

(server function, client function)

(server function) v GOT (server) can be monitored from a personal computer (MX Component) to perform indirect reading/writing at PLC CPU devices being monitored by GOT.

v A GOT (server) can be monitored from another GOT (client) to perform indirect reading/writing at PLC CPU devices being monitored by GOT (server).

v Even when monitoring other brand PLC CPUs, the server function can be used to perform reading/writing with the MX Component*1 alone.

v The client function can be used to perform indirect reading/writing at PLC CPU brands other than the PLC CPU brand to which GOT (client) is connected. v Communication is possible between GOT1000 and GOT-A900*2.

Worksite

Mitsubishi PLC

Mitsubishi PLC

Host personal computer (client)

Office

Bus connection

Worksite

Internet Bus connection

Data collected by MX Component

GOT-A900 (client)

GOT1000

Mail server

3

2

GOT1000

GOT1000 (FTP server)

Worksite

(Server)

Client function

Server function

RS-422 connection

RS-232 connection

Mitsubishi PLC Microcomputer board

Mail transmission function 3 Transmit mail from GOT to a personal computer

or cell phone *3

4 Host personal computer (FTP client) Files checked by general-purpose software such as FTP client tools

FTP server function 4 Direct checking/editing of data

in CF card (FTP server function) v Files in a CF card in the GOT can be directly read and written from a personal computer (alarms, recipes, hard copies, etc.).

v The alarm history display function can transmit alarm occurrence and recovery information by mail to a personal computer or cell phone.

v No need to visit every factory to collect CF cards from every GOT when several GOTs exist or a GOT exists at a distant from a personal computer.

[Devices required for gateway function use]

10

*1: Requires MX Component Version3 or later. MX Component is a communication assistance tool that permits communications from a personal computer without having to identify the communication protocol and module. Data logging, collection, and saving is possible by programming at VBA. Applications that run in MX Component (MX Sheet, etc.) can also be used. *2: The devices required for Gateway function use at GOT1000 differ from those required at GOT-A900. For details, refer to the GOT1000 Series Gateway Function Manual. *3: Requires an SMTP (mail server). The mail transmission range depends on the SMTP specifications. *4: Be sure to use either GT15-QBUS or GT15-QBUS2. *5: Be sure to use either GT15-ABUS or GT15-ABUS2. *6: Communication between the Gateway function and a PLC is possible by using a single Ethernet communication unit.

Standard 1MB

Standard 9MB

GT15

v Design screens without worrying about memory capacity.

Optional 8MB

9 MB

x9

Optional 48MB

57 MB

v BMP and JPEG* images can be used to create easy-to-understand screens. *: JPEG format is supported only by the GT15.

Dramatically improved display is attractive and easy to view

Font Standard font

An assortment of fonts allows more expression

Size 6 x 8 dot

Style Gothic

12 dot

Gothic

16 dot

Gothic / Mincho

12 dot

Gothic / Mincho

16 dot

Gothic / Mincho

TrueType font

24 to 128 dot

Windows® font

8 to 128 dot

Gothic / Mincho 1

High-quality font

v When using a Windows® font, the font style (italics, underline, italics underline) can also be specified.

*: Gothic and Mincho styles cannot be used together in the standard font.

v Attractive characters in all sizes. TrueType fonts can be used.

v Error information can be checked from a remote location away from the worksite.

• Ethernet communication unit (GT15-J71E71-100) • Communication unit for connection to PLC • Optional function board (GT15-FNB or GT15-QFNB (MM))

GOT-A900

3 MB

v Standard fonts, high-quality fonts, and TrueType fonts can be used in Gothic or Mincho styles*.

Office

FTP server function

Bus connection

Brand "A" PLC

Standard 3MB

x6

*: All TrueType (other than vertical scripts) and OpenType fonts can be displayed.

Ethernet GOT1000 (client)

GT11

v Standard 3MB memory on the GT11.

v Supports Windows® compatible fonts*.

Mail transmission function

1

2

Standard 512KB 512 KB

v GT15 is expandable to 57MB (optional) by using optional function board and CF card.

Server function & Client function 1 Collect data at a personal computer

GOT-F900

Features and recommended points

Gateway function

[Gateway function compatible connection formats]

v The Unicode2.1 compatible standard font, high-quality font, and TrueType font, display sharp and attractive characters in all languages. v Create elaborate, high-quality screens that are both attractive and easy to view.

More freedom in screen design

Component layering (Layer function) v Component (objects, figures) layering increases the freedom of design. v Display layering is possible for components such as changing numerical values and graphs, line graphs, bar graphs, photo data, and pointers, etc. v Offers effective use of a limited display area by allowing comments to be placed on lamps. Photo data & pointer

Connection Format (Between GOT and PLC) • Bus connection (MELSEC-Q)*4 • Bus connection (MELSEC-QnA/A)*5 Mitsubishi PLC/ • CPU direct connection Motion controller • Computer link connection (MELSEC-Q/QnA/A) • CC-Link connection (via G4) • Ethernet connection *6 • CPU direct connection Mitsubishi CNC (MELDAS C6/C64) connection • Ethernet connection *6 Other brand PLC Microcomputer board, personal computer, etc. (microcomputer connection) Temperature controller connection

Comment & lamp

Layer graphs Front layer

Front layer

Back layer

Back layer

Error occurence

Front layer~Back layer

Front layer~Back layer

11


For designers

For designers

Increase design efficacy with an impressive array of clever functions

Intuitive support tools for designing screens with graphics More flexible screen design with improved work efficiency and customization functions

Script Function

Comment groups v Up to 255 comment groups can be created in addition to basic comments. Comment group 1: Line A comment Comment group 2: Line B comment Comment group 3: Line C comment

Example of comment group use

1. Project script / screen script

(1) Line-specific comment groups are created. Line A comment

Line B comment

v GOT's unique programs allow for changes of display depending on projects and screens.

Individually edited

Line C comment

v Controlling GOT display by using scripts of GOT can reduce the load on PLCs (PLC CPU, microcomputer, etc.) dramatically.

2. Object script* v Drawing and display control functions can be specified for every object, allowing objects to easily be used in other projects.

(2) Import

[Comment registration]

v Scripts make screen display control highly flexible by changing properties (colors and display positions) and making the object design process flexible.

v CSV / Unicode text format files can be imported. Different files can also be input to individual comment groups, allowing the comment input task to be distributed among several workers, greatly reducing the required input time.

v Input support function of the GT Designer2 make it easy to specify functions and properties, thereby preventing spelling errors and reducing the time to look up control statements.

v The drawing software allows easy column and line insertions and comment No. changes similar to those offered by Microsoft ÂŽ Excel.

[Example of comment group use]

When "2" is selected

Line A error

When "3" is selected

Line B error

Line C error

Draw a line to show the average value according to monitor device values Q64P POWER

Q64P

Q25HCPU MODE RUN

QX42-S1

POWER

MODE RUN

QJ61CL12

QJ61BT-11

QX42-S1

POWER

Q25HCPU

ON

RUN

QJ61CL12

QJ61BT-11

PULL

USB

QJ71C24-R2 QJ61CL12

QJ61BT-11

ERR USER BAT BOOT

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8

PULL

QX42-S1

MODE

QJ71C24-R2

ERR USER BAT BOOT

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8

PULL

Q64P

Q25HCPU

QJ71C24-R2

ERR USER BAT BOOT

PULL

ON

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8

PULL

PULL

USB

ON

clear_object();

// Delete the previous object (including a line).

[w:TMP0003] = ([w:D0] + [w:D1] + [w:D2]) / 3;

// Calculate an average value.

[w:TMP0001] = 320 - (320*([w:TMP0003] /1000));

// Calculate the position to display a line.

USB

Select functions and properties from the item list

d_line(0, [w:TMP0001], 380,[w:TMP0001], 0, 3, 255); // Draw a line. [w:D0003] = [w:TMP0003];

Multilingual support

*:Optional function board is required. GT15...GT15-FNB or GT15-QFNB( M)

(1) Create the Japanese, English, and Korean comments in their respective columns.

Easy-to-read item management using Kanji

Kana-Kanji conversion function v This function enables the conversion of text entered in Kana (ASCII code) to Kanji. Users are allowed to enter operator names and product names in Kanji.

*: For details, refer to the "Comment Group" item.

12

Check contents of a selected item

// Assign the average value.

To switch between Japanese, English, and Korean screen

v Different language comments can be created at each comment column No. to switch languages simply by specifying the desired column No. at a language switching device. v Up to 10 columns* can be created for 1 comment No. v Examples of use (for switching between Japanese, English, and Korean) (1) Create the Japanese, English, and Korean comments in their respective columns. (2) At a language switching device, specify the No. of the column to be displayed. (3) The displayed comment (language) changes. • Language-specific alarm display screens can also be easily created. v Column comments can be created freely for applications, as well as for different languages.

Edit and insert selected items by using statement examples being displayed

(3) Displayed comment group can be switched by device.

v Line-specific comment groups can be created and displayed, and switching between those groups is possible, enabling easy integrated control of multiple lines in a single project's data.

Easy creation of a multilingual screen

Edit scripts directly

m Example of how to use object script (draw straight line on graph display) When "1" is selected

v Language-specific comment groups can also be created, with switching between the different language screens.

m GT Designer2 script editor screen (object script only)

Features and recommended points

Efficient input of extensive comment data by allotment

Switch-

Switch-

ing

If D10=1, Japanese displays

v After entering text with input keys (key code switches created by users), press Kanji conversion key (key code switch) to display the text in Kanji in Ascii input field.

ing

If D10=2, English displays

If D10=3, Korean displays For D10 language switching device

(2) At a language switching device, specify the No. of the column to be displayed. (3) The displayed comment (language) changes.

v Within ASCII text, the cursor movement function enables users to move the cursor to any place in order to add characters.

Optional function board is required. GT15...GT15-FNB or GT15-QFNB(

M)

13


For designers

For designers

Simplified maintenance through batch handling of recipe information Automated recipe operation without sequence programs

For history management of production conditions and precise analysis of problem causes

Advanced recipe This function allows material combination data and processing conditions data, etc. (device value) to be held at GOT, with only the required data being written/read to and from the PLC.

1. Extensive amount of setting files, device points, and record points.

Logging function v Collecting data from temperature controllers and other units with GOT can reduce the load on PLC. · 250 device points per setting, 32 settings per project can be set. v Collected data can be used for record and analytical purposes when being saved to a CF card. · Files can be saved in the GOT dedicated binary file, CSV and Unicode text file formats.

v A greatly expanded capacity permits up to 2048 files and 32767 device points. v Up to 240 device records can be handled by a single advanced recipe setting file.

PLC

2. Flexible recipe data can now be created.

Q25HCPU Q61P-A1

v Flexible recipe data can be created by combining advanced recipe settings and records.

MODE RUN ERR USER BAT BOOT

PULL

v Reading/writing is performed by specifying the recipe No. and record No., eliminating the need for a trigger device at each file. This reduces the number of required devices, and permits trigger device concentration.*1 v Up to 2048 blocks are possible, with 1 block comprising a sequential word device and random word device (1 point), and a bit device (1 point). v Because devices also permit bit and word combinations and random device settings, there is no need to concentrate the sequential devices, thereby economizing on the number of device points.

QX10

QX41

POWER

USB

PULL

QX41

QJ71BR11 RUN T.PASS SD ERR

QJ71BR11 MNG D.LINK RD ERR

RUN T.PASS SD ERR

MNG D.LINK RD ERR

0 1 2 3 4 5 6 7 8 9 A B C D E F

Features and recommended points

Smooth operation from collection of various data to saving time series files

Temperature controller

v Advanced recipe files can be edited on a personal computer.*2

Buffering area (GOT memory)

CF card

Usage example Number of device points (max. 32767 points / setting)

Device blocks (max. 2048 blocks / setting)

Advanced recipe setting

Advanced recipe setting 1: Curry Device

Device Comment

Record 1 Beef Curry

Record 2 Pork Curry

Collect device data from PLCs and temperature controllers into a buffering area

Save data in the buffering area to a CF card

Analyze data in the CF card (CSV or Unicode text file) on a personal computer

Record 3 Chicken Curry

D1000

Beef

300

0

0

D1001

Pork

0

300

0

D1002

Chicken

0

0

300

D1100

Onion

400

500

600

D1101

Potato

300

400

200

D1102

Carrot

200

250

150

Max. 2048 settings / project

Optional function board is required. GT15...GT15-FNB or GT15-QFNB(□M)

Easy-to-read logging data in a graph display

Historical trend graph v Data collected by the logging function can be displayed in a time series graph from a CF card as well as from a buffering area.

Records (max. 240 records / setting)

Display time and device value of a cursor position

3. Easy handling of recipe data at GOT v Recipes can be handled easily by GOT's utility function without having to create a recipe operation screen.

GOT main unit

Select a recipe file

Cursor

v The utility function permits the following operations: folder create/delete, advanced recipe file copy/delete/file name change, record write/read/consistency check. v Advanced recipe files can be converted to CSV files or Unicode text files.

Cursor

Enlarge scale

Recipe execution Cursor display: Displays a cursor

Advanced recipe information screen

*1: The "recipe No. saving device", the "record No. saving device", and the "external control device" advanced recipe common settings can be specified at the advanced recipe device dialog box in GT Designer2 (these settings are required when using an advanced recipe). Recipe data reading and writing occurs in accordance with external device ON/OFF switching, and that data displays onscreen. (It is also possible to specify a trigger device for reading/writing of each advanced recipe setting.) *2: The advanced recipe file has a binary format. It must therefore be converted to a CSV file or Unicode text file by using GT Designer2 or the GOT's utility. After being converted, only the device values can be edited.

14

Select a record and execute the recipe

Advanced recipe record list screen An optional function board is required. GT15...GT15-FNB or GT15-QFNB (□M)

Cursor movement (return): Moves the cursor backward

Zoom in: Enlarges the graph scale

· Data collected by the logging function can be displayed in graph form. Past data can be displayed simply by pressing a scroll switch. · Displays a cursor, device value and time of the cursor position, allowing for enlargement or reduction of scales. · Up to 32 data can be displayed in a graph; up to 8 graphs can be added to a screen. * Settings of the logging function are required in order to use historical trend graphs.

Optional function board is required. GT15...GT15-FNB or GT15-QFNB(□M)

15


For designers

Create designs the way you imagined them

Reduction in screen drawing time by half*1

Reduction in screen drawing time by half

®

Windows standard operability and menu configuration

Data compatibility with GT Designer

An intuitive tree display, with easy copying and deletion Project workspace

v Interactive wizard helps users create a new project by configuring necessary settings for the GOT1000. Start wizard

Easy to set system settings, screen switching settings, multiple communication settings

Display of actual GOT screen

Screen preview

Window preview

v Language switching, security level change and on/off image switching of objects can be checked with the GT Designer2 on a personal computer. Example of how to switch languages

Column No. of comment group Select a column No. of the comment group to be displayed

Select column No.1

Select column No.2

v The drawing software can display window screens (key window, overlapping window, superimposed window) just as they will appear at GOT, allowing them to be previewed. v The key pad can be displayed just as it will appear at GOT, allowing its position, size, and appearance etc., to be checked.

Workspace

It's easy to see the entire project so the screen to be edited can be selected right away.

Category workspace The device, color, and figure of components can be batch-changed in screen or category units, even when located on multiple screens. *: "Category" refers to objects or figures that have been grouped according to purpose.

Library workspace Frequently used components can be registered as "favorites", permitting quick access to an object or figure.

Property sheet

List display of object & figure setting content v A setting content list can be displayed for the selected object or figure. v Similar objects can be selected, and the color and font size can be set in one go. v Multiple same-type objects and figures can be selected, and their color and character size, etc., can be batch-changed.

Object & figure setting screen Dialog box

v A setting content screen displays by double-clicking the object or figure. v Figure changes are immediately reflected onscreen. This allows work to be performed while checking the onscreen results, thereby simplifying the process and reducing setting errors. *: This is possible at the "Property Sheet" as well.

Library editor Temporary area 16

Wizard function

Easy confirmation of screen display

Features and recommended points

Version2

User-friendly setting procedure puts even beginners at ease

Dedicated component editing screen

Display all settings in a list

Higher efficiency by using familiar software

Improved import/ export function v Settings of the following functions can be imported/exported: logging, advanced recipe, advanced user alarm, recipe, alarm history and comment registration. v Device data, range settings, device values, and comments, which have been created in a CSV/Unicode text file format, can easily be imported/exported to and from the GT Designer2.

Read created data into the GT Designer2 (Import)

Edit a spreadsheet with software such as Microsoft Excel

import /export

Save contents of settings of the GT Designer2 to CSV/Unicode text files (Export)

Better project data maintenance efficiency

Project data consistency check function

Consistency check

v Consistency checks between the GOT's project data and the personal computer project data can be performed. v This allows project data inconsistencies to be identified, thereby reducing unnecessary uploads and downloads.

v A component editing screen displays by double-clicking a registered component at the library workspace.

Reliably compatible with existing GOT projects reuse work friendly to customer existing resources compatible

v Editing of registered components is quick and easy.

Forward compatibility

Smoother screen creation v Placing objects in a temporary area facilitates smoother screen creation and screen layout change operations.

v GT Designer → GT Designer2 compatibility*2 GT Designer2 is compatible with project data created by GT Designer. v GOT-900 → GOT1000 compatibility*2 GOT1000 is compatible with project data created at GOT-900. *1: Compared to Mitsubishi Electric's GT Designer. *2: Forward compatibility does not extend to certain data and functions. Moreover, GOT1000 screen data cannot be used at GOT-900.

17


For designers

For operators

Efficient debugging

State-of-the-art operation environment

Dramatically improved GOT total response Virtual GOT

1. Debugging is possible from a single personal computer, without actual GOT and PLC operation required.*1 v A GT Simulator2 screen debugging function permits screen editing in GT Designer2 with the results immediately verifiable in GT Simulater2, thereby greatly reducing debugging man-hours. v The input to a touch switch is simulated by clicking on the touch switch on GT Simulator2 with the mouse. The result of input to the touch switch can be confirmed by a display change on GT Simulator2, the device monitor screen on GX Simulator, or the ladder monitor of GX Developer. v GT Simulator2 can be used in combination with a sequence program created in GX Developer to recreate the screen motion, allowing debugging to be performed in an intuitive manner. v System alarm and script error information can be checked in GT Simulator2, even if no system alarm settings have been specified in GT Designer2. Drawing software

Virtual GOT

Click with mouse

Omron Corp. PLC*2

GT15 response performance comparison

Randomly monitor 250 numerical displays (word devices) (1.0 for computer link connection is a comparison standard)

Bus connection CPU direct connection Computer link connection

v Ultra high performance processing power to satisfy the most complex and demanding of applications. Virtual PLC

Programming software

GX Simulator

GX Developer

Virtual PLC

Communication / monitoring

MELSECNET/10 connection (Transient)

CC-Link (ID) connection (Transient)

Ethernet connection

High-speed communication

FX direct connection

v High-speed RS-232 communication (max. 115.2kbps). v GT15 high-speed communication is possible by bus connection. v High-speed communication is possible for connections with both Mitsubishi and other brand PLCs.

[MELSEC FX3UC]

Other brand direct connection [Yokogawa Electric. FA-M3]

0.2

0.4

0.6

0.8

1.0

For connectable PLC models, see the "Connectable model list" from page 28. For connection format specific features, see the "Connection configuration" section from page 32.

Programming software

GX Developer

Screen image at personal computer

Click with mouse

Sharp display that's easy to view

Accommodates production site globalization

65536-colors full color / monochrome 16 gray scales

Easy switching between different languages

v The GT15 lineup offers an array of display colors depending on usages.

GT Simulator 2 RS-232 / RS422 connection

Mitsubishi PLC

PLC ⇔ Personal Computer Connection RS-232/RS-422

v High-speed drawing of figures and characters was realized through the development of drawing chip especially for the GOT1000 Series. v Sharp and quick drawing of complex, layered component screens, and detailed photographic data.

High-speed computing GT11: Equipped with 64-bit RISC processor GT15: Equipped with 64-bit super-scalar RISC processor

Load program

Load drawing data Mitsubishi PLC (MELDS C6/C64)

Approx. 4 times faster response

[Using MELSEC-Q series]

2. Debugging is possible by connection with a PLC, without actual GOT operation required

Mitsubishi PLC (Q/QnA/A/FX series)

GOT- 900 GOT1000

High-speed drawing Equipped with a high-speed drawing chip (GT15 only).

Sequence program RUN

Connectable PLCs

Drawing, computing, communication; a triad of high-speed response functions The GOT1000 Series offers faster response in drawing, computing, and communication, reducing monitoring and operation stress.

GX Simulator

Debugging can be performed using a direct CPU connection between a personal computer (GT Simulator2) and a PLC, without actual GOT unit. Connection is possible to Mitsubishi and Omron PLCs*2.

Response comparison with GOT-900 series

Features and recommended points

Version2

RS-232 connection

Omron PLC

RS-232

3. Device monitor function permits monitoring of a wide array of devices v Monitoring is possible for displayed devices. (GOT internal devices can also be monitored.) v In addition to displayed devices, monitoring is also possible for devices with common settings, as well as for overlapping windows 1 & 2, and superimposed windows 1 & 2.

GT15MM-MTBM : Standard model offers a 256-colors display. 65536 colors are available when the multi-color display board is installed. JPEG and BMP images can be used at the troubleshooting screen, etc., for vivid and easy-to-understand displays. GT15MM-VNBM N E W : Standard model offers either a 256-colors or 16-colors display.

v The GT11 is available with either a 256-colors display or a monochrome (black & white) display. The 256-colors type features a long-life backlight with a lifespan of 75,000 hours or more. The monochrome (black & white) display offers a 16 gray scales for improved expression.

v While observing the operation image, the customer's screen specifications can be arranged without actual unit operation.

v Correctly display Simplified Chinese and Traditional Chinese characters N E W *1 (GT15 only) v Allows the creation of elaborate, high-quality screens that are both attractive and easy to view.

v A high intensity, with a wide-view angle and vivid colors offers sharp and attractive displays. v A high transmissivity protection sheet* is available to protect the screen and prevent reflection, resulting in a clear, easy-to-view screen. *: The protection sheet is an optional item.

v One-touch switching between different-language screens*2 accommodates different languages spoken by production site operators.

GT15

v Because devices can be registered freely, it is possible to register multiple devices which are to be monitored.

4. Powerful support of customer specifications compatibility checks and document creation

v The Unicode2.1 compatible standard font, high-quality font, and TrueType font, display sharp and attractive characters in all languages.

Onetouch language switching 65536 colors

256 colors

GT11

v Display screen snapshots can be saved to the personal computer's hard disk as BMP/JPEG files that are extremely useful when creating specifications and operation manuals.

18

*1: Requires GX Simulator (ladder logic test tool). *2: For connectable PLC model information, see the "Connectable model list" on page 28. [Unsupported functions] For lists of functions which cannot be simulated (utility function, optional function, etc.), refer to the GT Simulator 2 Version 2 Operation Manual.

*1: Optional function board is required. GT15...GT15-FNB or GT15-QFNB(MM) *2: For function details, see the "Multilingual support " section on page 12. STN color, 256 colors

STN monochrome 16 gray scales

19


For initial startup & adjustment operators

For minimizing procedure man-hours and setup Easy cable connection without opening the cabinet

Equipped with front USB interface

GT Designer 2 Office

High-speed downloading/ uploading* via Ethernet

v A front USB interface allows cables to be connected without having to open the cabinet. Work efficiency is improved by eliminating the time-consuming process of opening and closing the cabinet door at GOT data transmissions.

Download Upload

v Project data from a personal computer at a remote site can be downloaded and uploaded to a GOT terminal by way of Ethernet.

v The USB interface is a standard item for all models. Data transmission can be up to 20 times faster than the previous RS-232 format, greatly reducing the time required for startup and adjustment.

Comparison of project data downloading times

GOT-900

v Equipped with an IP67f-rated port cover as standard. When secured by screws, the cover complies with the IP67f* standard.

Worksite

Mitsubishi PLC

GOT1000 100Mbps Up to 20 times faster (Ethernet)

v The IP67f-rated port cover is easily opened/closed by coin screws.

Data transmission time

Short

Long

Comparison of project data downloading times

GOT-900

38.4kbps

(RS-232)

GOT1000

12Mbps Up to

(USB)

20 times faster

Data transmission time

Short

GT15

Long

With USB cable

Ethernet

38.4kbps

(RS-232)

*: Compliance cannot be guaranteed in all customer environments. Moreover, the IP67f rating does not apply when a USB cable is connected.

GT11

Standard item IP67f (with IP67f-rated port cover installed)

FA transparent function

Easy GOT data transmissions & setup

Standard-item RS-232 interface

Standard-item CF card interface

v Both the GT15 and GT11 have RS-232 interfaces located in convenient positions (bottom, and side face, respectively) for cable connection.

v Sequence program debugging, startup, and adjustment can be performed via GOT's front USB There is no need to open the cabinet and change cable connections. (Operation is also possible via the RS-232 interface.)*2

GOT-900

v When GOT is connected to a Mitsubishi PLC by bus connection*3 or direct CPU connection, program reading, writing, and monitoring can be performed via GOT.

GOT1000

v All models are equipped with a CF card interface as standard. v Permits rapid GOT data transmissions even when GOT is not connected by cable to a personal computer. v When using multiple GOT units, a single CF card enables a quick GOT setup procedure simply by copying the data to each GOT unit.

Comparison of project data downloading times

interface.*1

*: Requires an Ethernet communication unit (GT15-J71E71-100) installed in a GOT main unit where basic functions have also been installed. Downloading/uploading other than the Boot OS and OS installation is possible. (Resource data can only be uploaded.)

For GOT data transmissions & a variety of external connections

v Used for FA device connection, data transmission, bar-code reader connection, etc.

Edit sequence programs without opening the cabinet

Download Upload

Features and recommended points

Project data can be maintained from a remote location

38.4kbps

(RS-232)

115.2kbps Up to

(RS-232)

4

times faster

Data transmission time

Short

Long

*1: Requires GX Developer Version 8.22Y or later. *2: When the GOT internal RS-232 interface is used to connect to the PLC, GOT can only be connected to a personal computer by the USB interface. *3: When multiple GOT units are connected by a bus connection, the FA transparent function can be used at each of the GOT units.

Handy GOT M0

Y100

M500

Y70

coming soon

GT11

GT15

RS-422 interface

GX Developer

USB/RS-232

M0

Y100

M500

Y70

Bus connection or direct CPU connection

MELSECNET/10, etc.

*: For software access ranges when using the FA transparent function, refer to manual for the software being used.

20

RS-232 interface

CF card interface

RS-232 interface

CF card interface

RS-232 interface

CF card interface

21


For maintenance personnel

Rapid diagnostics and identification to minimize machine downtime From error detection to recovery

The GOT1000 Series offers quick error detection and cause identification, enabling a speedy system recovery. Alarm observation subjects

Advanced alarm features

1. A wider monitoring range protects even large-scale systems. 2. Rapid detection and corrective action for a wide array of alarms. 3. Easy-to-understand error displays for the operator. 4. Improved system alarms. 5. Support in identifying alarm causes.

Alarm observation settings Unit "A" observation settings

Alarm observation for up to 32767 devices

Alarm display settings

History file saving

Display of active and recovery-completed alarms

Unit "B" observation settings

Display of active alarms only

Max. of 255 settings

3. Easy-to-understand display v The use of colors and popups produce easily recognizable alarm displays. v Ensures that alarms are not overlooked and that the alarm content is understood, resulting in a speedy system recovery.

Display subject switching Display switching is possible to display only active alarms or to display all content.

Popup display

Comment display color

1. A wider monitoring range protects even large-scale systems. v Alarm observation is possible for up to 32767 devices, with a maximum of 255 alarm observation setting groups. v 3 types of alarm displays can be specified for a single alarm observation setting. v Up to 32767 alarms can be saved in the alarm history. v Batch display of large amounts of alarm information in large-scale systems, and unit-specific classification for easy management.

Comment display colors can be specified for each alarm status (occurred, restored, and checked) and for each level and group, etc.

Floating alarm display Permits the entire text of long comments which cannot be contained in the display area to be read.

Features and recommended points

Advanced alarm

Details display JPEG images can be displayed in the details display area.

Sorting A sorting function permits the display order of the date & time, level, group, alarm status, occurrence count, and downtime items to be changed.

2. Rapid detection and corrective action for a wide array of alarms.

For example...

4-step alarm notification v Alarm occurrence conditions can be divided into 4 steps, and conveyed to the operator in an easy-to-understand, step-by-step format.

1. Alarms by line (upper step) 2. Alarms by unit (middle step) 3. Alarm content (general step) 4. Troubleshooting (details step)

Alarm occurrence

Step Alarms by line

1

(upper step) Step

Alarms by unit

2

(middle step) Step Alarm content

3

Step Troubleshooting

Line "A" stops

When multiple alarms occur, the above format permits the operator to quickly organize and identify the alarm conditions (where, what kind of alarm), resulting in effective troubleshooting.

Where is the error?

(general step)

4

(details screen)

Device "A" error

What kind of error?

v The 4 steps shown above can be freely defined to suit the application in question, with switching between the step displays performed by the step switching device or by touch-screen operation.

Out of material Material When will recovery occur? replenishment

Cursor display color

Group-specific & level-specific displays v Alarms can be classified by group and level, with only the specified alarms being displayed. v This makes it easy to identify the locations and types of alarms, even when many alarms have occurred, and permits the higher priority alarms to be handled first, resulting in a speedy system recovery.

22

Alarm

Group

Level

M0 M1 M2 M3 M4 M5 M6 M7 M8 M9

Transport G Transport G Transport G Transport G Transport G Process G Process G Process G Process G Process G

Mid-level Mid-level Mid-level Mid-level Major Major Minor Minor Minor Minor

Group

Transport G alarm display Transport G major alarms display

2. By level Alarms are divided into levels (major, mid-level, minor), with only the specified level alarms displaying. 3. Combination group & level Only the specified group and level alarms display.

A popup display format ensures that user alarms and system alarms are not missed. The background color can be specified.

4. Improved system alarms v The PLC/GOT/Network monitoring subject can be specified in advance, with only those specified alarms being displayed. v If desired, only the active alarms are displayed. An alarm history display and history file saving are also possible.

5. Support in identifying alarm causes (utility function)

Combination level & group

Level

1. By group Alarms are divided into groups (transport unit group, processing unit group, etc.), with alarms displaying only for the specified groups.

The cursor display color can be specified. Alarm displays are harder to miss, and the freedom of screen design has been increased.

Alarm popup display

Minor alarm display

v Alarm occurrence conditions can be displayed in time-series graph form. v Alarm occurrence counts can be displayed in bar-graph form. v A graphical statistics display facilitates efficient analysis of error causes.

23


For maintenance personnel

For easy monitoring and other operations of Mitsubishi FA devices

Convenient maintenance tools

mMaintenance schedule notification function (GT15 only) 1st notification

1. Color-coded front face LED

System alarm occurs

v The color of the LED on the front of the GOT unit indicates whether the backlight is OFF or has expired. [POWER LED: Color-coded message] Green ON

When normal power is being supplied

Orange ON

When in screen-save mode

Orange/green blinking

When backlight life has expired

OFF

When power is not being supplied

2. Maintenance schedule notification function (GT15 only) v The backlight lifespan can be monitored by an automatic "power ON time" count function, combined with a 2-stage maintenance schedule notification function.

2nd notification

System alarm occurs

v Communication line, information from the host and other stations can be monitored to check the communication status.

Servo amplifier monitor function

Easy adjustment of Q series motion controller

Easy startup and adjustment of servo amplifier

v When multiple servo amplifiers are connected, monitor screens can be easily switched on a GOT by specifying station numbers. *3: Available monitoring functions vary according to the servo amplifier type.

CNC monitor function

Easy-to-understand display of buffer memory values and I/O information

Space and cost saving because no dedicated display device is required

OFF status of I/O units can be monitored and changed. v When a QCPU (Q mode) is in use, CPU operating status and existing errors can be monitored by PLC diagnosis.

v MELSEC-A series, FX series PLC sequence programs can be edited in a list format (instruction word). v Permits minor program changes onsite, even without peripheral devices. v The GT15 permits sequence program editing while viewing the ladder (combined with the ladder monitor function).

v In a system which outputs pulse strings, GOT can be connected to a servo amplifier in a serial connection to perform the following operations: setting up, monitoring, alarm display, diagnosis, parameter setting, and test operations.*3

Intelligent unit monitor function

v Buffering memory values of intelligent function units and ON/

NEW

Convenient method for minor program changes onsite

24

v Network status of the MELSECNET/H, MELSECNET/10 and MELSECNET II can be monitored on a dedicated screen.

Q series motion monitor function

*2: Supported only if the Q series motion controller CPU has SV13/SV22 OS version. Moreover, available functions of Q series motion monitor vary according to the CPU type.

v Mitsubishi PLC CPU devices can be monitored and changed. • Monitoring can be performed by selecting the device to be monitored, or by specifying the initial device. • The timer (T) / counter (C) current values and setting values can be changed. v A special function unit's buffer memory (BM) can be monitored and changed. v The display format (decimal / hexadecimal) and the device comment display status (ON/OFF) can be switched.

GT15...GT15-FNB or GT15-QFNB (MM) GT11...GT11-50FNB

v Monitoring of Mitsubishi PLC sequence program and various searches of devices can be performed. • Monitoring in ladder format. • Device values and Timer (T)/counter (C) setting values can be changed. • A coil (or contact) can be touched to search for contacts (or coils) of the same device.*1

v Monitoring and parameter settings can be performed for up to 3 units of Q172(N) /Q173(N) on the same base unit.

Sequence device monitoring / changes

Requires optional function board.

At-a-glance monitoring of MELSECNET network status

v Monitoring of servo amplifiers and parameter settings of Q motion controllers can be performed.*2

Backlight maintenance required.

System monitor function

List editor for A / List editor for FX

Sequence program monitoring & troubleshooting

*1: MELSEC-Q/QnA series only.

v Facilitates scheduled maintenance, thereby preventing system malfunctions. Battery required. GT15...GT15-BAT

Network monitor function

v When a problem occurs, an alarm history can be displayed, and a back-tracking ladder search can be performed to find the contact which triggered the alarm.

Backlight maintenance required soon.

v Monitored subjects • Backlight, display area (power ON time) • Touch-keys (key pressing count) • Internal flash memory (writings count)

Requires optional function board. GT15...GT15-FNB or GT15-QFNB (MM)

Ladder monitor function

Features and recommended points

Color-coded front face LED & maintenance schedule notification function

*4

v When a MELDAS C6/64 is connected, position display monitor, alarm diagnosis monitor, and tool offset parameters can be set on GOT as well as on a display device dedicated to MELDAS. v Up to 64 CNC units can be monitored in an Ethernet connection. Only a control station can be monitored in a MELSECNET/10 connection.

List editor for FX

*4: Supported by GT15 series XGA and SVGA models.

List editor for A Optional function board is required for functions shown on this page. GT15...GT15-FNB or GT15-QFNB (MM). GT15-QFNB (MM) is required in order to use Q/QnA ladder monitor function.

25


Handy GOT

Unlimited mobility wherever you are within a facility coming soon

Handy GOT

FA device interconnection cables

Portable and wearable Handy terminals can also be mounted on a wall or a machine

RS-232/RS-422

RS-232/RS-422

FA devices

Flexible usage and connectivity of Handy terminals 1 External connection cable GT11H-CMMM-37P CF card interface

Key type selector switch

Hook to attach neck strap

Emergency stop switch USB interface

2 PLC interconnection relay cable

RS-232/RS-422

To power supply and operation switches

FA devices To power supply and operation switches

1 External connection cable GT11H-CMMM Handy GOT Removable logo mark

Model name

Connection configuration

Connected FA device FX0S, FX0N, FX1NC, FX2NC,

Connection port

1 External connection cable

Features and recommended points

GT1155HS-QSBD/GT1150HS-QLBD

2 FA device interconnection relay cable

CPU programming port

FX3U, FX3UC,

Grip switch

FX1S, FX1N

CPU programming port or FX1N-422-BD GT11H-C15R4-8P(1.5m)

LED lamp for grip switch 6 operation switches Replaceable name label

mKey type selector switch

mUSB interface (standard item)

vImproved safety by using 2 break contacts connected in series, either of which can execute a stop command when being switched off.

mGrip switch

v3 position switch is adopted. (OFF-ON-OFF) Connected to an external device as a dead-man switch, grip switch can be used for the immediate execution of a command to stop a machine.

m6 operation switches

vWired directly to an external device input as pushbutton switches, 6 operation switches can be used to operate and stop a machine. Furthermore, the operation switch names can be changed as desired. vThe control panel is equipped with an LED lamp (green) for verifying operation of these switches.

A, QnA, A motion controller

GT11H-CMMM-37P MMM: 30(3m)/60(6m)/100(10m)

CPU programming port GT11H-C15R4-25P(1.5m)

Connectable FA devices (see "Connectable model list" on page 28)

GT1155HS-QSBD

mCF card interface

vThe CF card interface permits fast GOT data transmission.

mEmergency stop switch of 2 break contacts

RS422

CPU programming port or FX2N-422-BD

Lightweight, thin and easy-to-handle cable

vGT1155HS-QSBD has 256 colors; GT1150HS-QLBD has 16 gray scales.

vRestricts access to certain operations (manual/auto switching, mode selection, setup change, etc.) to authorized operators.

FX2N

One-touch connection of optional cable

Display area GT1155HS-QSBD : 256 colors GT1150HS-QLBD : 16 gray scales Equipped with touch switches equivalent of GT11.

mDisplay equivalent of GT11

26

Hand strap

To be fabricated by user.

GT1150HS-QLBD A series computer link unit, QnA/Q serial communication unit, Mitsubishi inverter, other brand PLC, microcomputer, servo, CNC, temperature controller

vThe USB interface permits fast data transmission between GT Designer2 and GOT.

Q

mRS-232 interface

vThe RS-232 interface is provided for GOT data transmission when the USB interface is not used.

RS232

mRS-232 / RS-422 communication

CPU programming port

Connectable FA devices (see "Connectable model list" on page 28)

A series computer link unit, QnA/Q serial communication unit, Mitsubishi inverter, other brand FA device, microcomputer, servo, CNC

vEither the RS-232 or RS-422 format can be selected for communication with connected devices.

Termination of GT11HCMMM is required in accordance with the devices to be connected.

Termination of GT11HCMMM is required in accordance with the devices to be connected.

GT11H-CMMM MMM: 30(3m)/60(6m)/100(10m)

GT11H-C30-37P

GT11H-C30-37P

GT11H-CMMM

GT11H-C15R2-6P(1.5m)

To be fabricated by user.

MMM: 30(3m)/60(6m)/100(10m)

mOptional devices vEmergency stop switch guard (GT11H-50ESCOV)

vProtective sheet (GT11H-50PSC) For RS-422 connection

vCF card vOptional function board (GT11-50FNB) vReplacement battery (GT11-50BAT) vExternal connection cable vPersonal computer connection cable (GT01-C30R2-6P (RS-232 cable)) (GT09-C20USB-5P (USB cable))

The connection distance between Handy GOT and PLC must not exceed 11.5m. For RS-232 connection The connection distance between Handy GOT and PLC must not exceed 6m. When the connection distance between Handy GOT and PLC exceeds the cable length shown in the table, the user must fabricate an FA device interconnection relay cable. For further connection cable details, refer to the Handy GOT Operation Manual.

27


Connectable model list The GOT1000 series allows connection to Mitsubishi PLCs and a variety of other FA devices.

mModules that can be connected with Mitsubishi PLC

[PLC/motion controller] Mitsubishi PLCs/motion controllers Series

Model name

Connection configuration Bus CPU Computer- MELSEC CC-Link CC-Link Ethernet (ID) (via G4) connection direct link con- NET/10 *1 *4 *1*3 *1*4 *1*2 connection nection *5 j *7

j

j

j

j

j

j

j

*8

MELSECA series (AnSCPU type) *13

2 2

2

j *9

j

*11

j

2 j

*11

j

j

*8*10

2

j

j

2

j

j

2

2

j

*10

2

j

MELSECA series *13

j j*12

j

j

j

j

2

j

j

Motion controller CPU (Q series)

j

Motion controller CPU (A series) (large type)

j

j

j

j

2

j

2

Motion controller CPU (A series) (small type) *13

j *14

*1: Supported only by the GT15. *2: When connecting multiple GOTs, note that the following GOT models cannot be used together: GOT1000 series, GOT-A900 series, GOT800 series, and A77GOT. *3: When MELSEC/H is used in NET10 Mode, the GOT terminal cannot be connected directly to a Remote I/O station. *4: CC-Link (ID): Connected as CC-Link (intelligent device station). CC-Link (via G4): Connected to a CC-Link system via AJ65BT-G4-S3. *5: When using A Series computer link (C24 modules) with QCPU/QnACPU, only the device ranges within QnACPU specifications are supported. The following devices cannot be monitored: · Devices that have been newly added to the QCPU/QnACPU. · Latch relay (L) and step relay (S). In the QCPU/QnACPU, the latch relay (L) and step relay (S) are separate devices from the internal relay (M), but the internal relay is nonetheless accessed when either the latch relay or step relay is specified. · File register (R) · Local devices *6: Use CPU function version "B" or later in a multiple CPU system. *7: When using a bus extension connector box, it must be installed at an extension base. (It cannot be installed at the main base.) *8: Use function version "B" or later for the CPU and MELSECNET/H network unit. *9: Does not support automatic system switch. (If there is only 1 GOT, plug the GOT cable into the CPU of the control system to be monitored. If there are 2 GOTs, plug each of them into the respective CPUs of the "A" and "B" systems to be monitored.) *10: Does not support automatic system switch. (Use the script to switch systems.) *11: With redundant system, the standby system automatically takes over the control if control system goes down. *12: In Q4ARCPU redundant systems, GOT must be bus-connected to the last stage's redundant system extension base A68RB version "B" or later. *13: Computer link unit software version "U" or later must be used for the A2SCPU, A2SHCPU,

28

Series

MELSECFX series

Model name A2USCPU A2USCPU-S1 A2USHCPU-S1 A1SCPU A1SCPUC24-R2 A1SHCPU A2SCPU A2SCPU-S1 A2SHCPU A2SHCPU-S1 A1SJCPU A1SJCPU-S3 A1SJHCPU A0J2HCPU A0J2HCPUP21 A0J2HCPUR21 A0J2HCPU-DC24 A2CCPU A2CCPUP21 A2CCPUR21 A2CCPUC24 A2CCPUC24-PRF A2CJCPU-S3 A1FXCPU Q172CPU *16 Q173CPU *16 Q172CPUN *16 Q173CPUN *16 Q172HCPU Q173HCPU A273UCPU A273UHCPU A273UHCPU-S3 A373UCPU A373UCPU-S3 A171SCPU A171SCPU-S3 A171SCPU-S3N A171SHCPU A171SHCPUN A172SHCPU A172SHCPUN A173UHCPU A173UHCPU-S1 FX0S FX0N FX1S FX1N FX1NC FX2N FX2NC FX3U FX3UC

vFor computer link connection

Connection configuration Bus CPU Computer- MELSEC CC-Link CC-Link Ethernet (ID) (via G4) connection direct link con- NET/10 *1 *4 *1*3 *1*4 *1*2 connection nection *5 j

MELSEC-Q series (Q mode) MELSECNET/H remote I/O stations

j j

MELSEC-Q series (A mode)

j j j

j

*14

j

2

j

2 MELSEC-QnA series

j

j

*15

j

j

*14

j

2

j

2

j

j*14 j j

2

2

2

2

2

2

j

j

2

2

2

2

2 2

j j

2 2

2 2

2 2

2 2

2 2

2

j

j

j

j

j

j

*18

*18

*19

*19

*19

*19

*19

j

j

j

j

j

j

j

j

2

j

j

j j

j *17

j

j

MELSEC-A series A series Motion controller CPU

j

j

j

j

2

*2 *2

*3

*4 *4 *4 *4 *4 *4 *4 *4 *4 *4 *4 *6 *4 *5 *5 *5 *5 *6 *5 *6 *5 *4

RS-232 RS-232 RS-232 RS-232 RS-422/485 Module connector RS-232 RS-422/485 RS-232 RS-232 RS-422 RS-232 RS-232 RS-422 RS-232 RS-232 RS-232 RS-232 RS-232 RS-232 RS-232 RS-422/485 RS-232 RS-422/485 RS-232 RS-232

j MELSEC-QnA series

j MELSEC-Q series (A mode) MELSEC-A series A series Motion controller CPU

RS-422/485 RS-232 RS-422/485 RS-232 RS-422/485 RS-232 ! ! RS-422/485 RS-232 RS-422/485 RS-422/485 RS-232 RS-422/485 RS-422/485 RS-232 RS-422/485 RS-232 RS-422/485 RS-422/485 ! ! ! ! ! RS-422/485

· File register (R) · Local devices *2: With function version "A", CH1 or CH2 can be connected. With function version "B" or later, both CH1 and CH2 can be connected. *3: Only CH2 can be connected. *4: Either CH1 or CH2 can be connected. *5:: When connecting to A1SHCPU, A2SCPU(S1), A2SHCPU(S1), A1SJHCPU, A0J2HCPU, A171SHCPU(N), A172SHCPU(N), use computer link module software version U or later version. *6: Computer link module/serial communication module operate within the range of devices available on AnACPU. (R device cannot be used.)

vFor MELSECNET/10 connection

MELSEC-Q series (Q mode)*1

*20

QJ71C24 QJ71C24-R2 QJ71C24N QJ71C24N-R2 QJ71C24N-R4 QJ71CMO A1SJ71UC24-R2 A1SJ71UC24-R4 AJ71QC24 AJ71QC24-R2 AJ71QC24-R4 AJ71QC24N AJ71QC24N-R2 AJ71QC24N-R4 A1SJ71QC24 A1SJ71QC24-R2 A1SJ71QC24N A1SJ71QC24N-R2 AJ71UC24 AJ71UC24 A1SJ71UC24-R2 A1SJ71UC24-R4 A1SJ71C24-R2 A1SJ71C24-R4 A1SCPUC24-R2 A2CCPUC24

*1: RS-485 communication is not possible; therefore, A0J2-C214-S1 is not available. When using A Series computer link (C24 modules) with QCPU/QnACPU, only the device ranges within QnACPU specifications are supported. The following devices cannot be monitored: · Devices that have been newly added to the QCPU/QnACPU. · Latch relay (L) and step relay (S). In the QCPU/QnACPU, the latch relay (L) and step relay (S) are separate devices from the internal relay (M), but the internal relay is nonetheless accessed when either the latch relay or step relay is specified.

CPU series

2

Computer link modules/serial communication modules *1 Model CH1 CH2

CPU series

vFor Ethernet connection

MELSECNET/H(NET/10 mode), MELSECNET/10 modules Optical loop Coaxial bus QJ71LP21 QJ71LP21-25 QJ71LP21S-25 AJ71QLP21 AJ71QLP21S A1SJ71QLP21 A1SJ71QLP21S AJ71LP21 A1SJ71LP21

QJ71BR11

CPU series MELSEC-Q series (Q mode)

AJ71QBR11 A1SJ71QBR11 MELSEC-QnA series AJ71BR11 A1SJ71BR11

*1: Use function version "B" or later for the CPU and MELSECNET/H network unit.

2

j

2

2

2

2

2

A1SHCPU, A1SJHCPU, A0J2HCPU, A171SHCPU, and A172SHCPU computer link connections. The A0J2-C214-S1, dedicated computer link unit for A0J2HCPU, cannot be used. *14: Only the following software version or later can be used to write data to the AnNCPU (S1), A2SCPU, A0J2HCPU, and A2CCPU. Earlier versions cannot be used. · AnNCPU (S1) : A "with link" status requires version "L" or later, and a "without link" status requires version "H" or later. · A2SCPU : Version "H" or later · A0J2HCPU (with link/without link) : Version "E" or later · A0J2HCPU-DC24 : Version "B" or later · A2CCPU : Version "H" or later *15: Cannot connect to bus if an extension base is connected. *16: Use of the SV13, SV22, or V43 requires a motion controller with the following OS version installed. SW6RN-SV13Q□: 00H or later (00E or later when Q172CPU, Q173CPU and bus connection, or direct CPU connection exists) SW6RN-SV22Q□: 00H or later (00E or later when Q172CPU, Q173CPU and bus connection, or direct CPU connection exists) SW6RN-SV43Q□: 00B or later *17: Only a USB interface is available on Q172HCPU and Q173HCPU units. The Q172HCPU and Q173HCPU can be accessed using a multi-CPU system QCPU RS-232. *18: Use a unit with the following serial No. Q172CPU Serial No. K******* or later Q173CPU Serial No. J******* or later *19: Use a unit with the following serial No. Q172CPU Serial No. N******* or later Q173CPU Serial No. M******* or later *20: If an extension base is to be used, use the A168B.

vFor CC-Link (ID) connection *1 CPU series MELSEC-Q series (Q mode) MELSEC-QnA series MELSEC-Q series (A mode) MELSEC-A series A series Motion controller CPU

CC-Link unit QJ61BT11 QJ61BT11N AJ61QBT11 A1SJ61QBT11 AJ61BT11 A1SJ61BT11

Connectable model list

Q00JCPU *6 Q00CPU *6 Q01CPU *6 Q02CPU *6 Q02HCPU MELSEC*6 Q06HCPU Q series *6 Q12HCPU (Q mode) Q25HCPU Q12PHCPU Q25PHCPU Q12PRHCPU Q25PRHCPU MELSECNET/H QJ72LP25-25 remote I/O QJ72LP25G QJ72BR15 stations Q02CPU-A MELSECQ02HCPU-A Q series Q06HCPU-A (A mode) Q2ACPU Q2ACPU-S1 MELSECQ3ACPU QnA series (QnACPU type) Q4ACPU Q4ARCPU Q2ASCPU MELSECQ2ASCPU-S1 QnA series Q2ASHCPU (QnASCPU type) Q2ASHCPU-S1 A2UCPU A2UCPU-S1 A3UCPU A4UCPU A2ACPU A2ACPUP21 A2ACPUR21 A2ACPU-S1 A2ACPUP21-S1 A2ACPUR21-S1 A3ACPU A3ACPUP21 MELSECA3ACPUR21 A series (AnCPU type) A1NCPU A1NCPUP21 A1NCPUR21 A2NCPU A2NCPUP21 A2NCPUR21 A2NCPU-S1 A2NCPUP21-S1 A2NCPUR21-S1 A3NCPU A3NCPUP21 A3NCPUR21

In addition to a bus connection, GT15 can also be connected to a MELSECNET/10 or Ethernet network. The GT11 is equipped with RS-232 and RS-422 interfaces (as standard) which can be used in an alternating manner, thereby enabling multiple GOTs to be connected.

*2 *2 *2 *2

*1: This is a "Ver.1 intelligent device station" permitting monitoring by transient and cyclic communication. Cyclic communication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the CCLink master/local unit being used. *2: GOT can perform transient communication only with CC-Link units running function version "B" and software version "J" or later.

MELSEC-Q series (A mode) MELSEC-A series A series Motion controller CPU

Ethernet module *1 QJ71E71-100 QJ71E71-B5 QJ71E71-B2 QJ71E71 AJ71QE71N3-T AJ71QE71N-B5 AJ71QE71N-B2 AJ71QE71N-T AJ71QE71N-B5T AJ71QE71 AJ71QE71-B5 AJ71E71N3-T AJ71E71N-B5 AJ71E71N-B2 AJ71E71N-T AJ71E71N-B5T AJ71E71-S3

A1SJ71QE71N3-T A1SJ71QE71N-B5 A1SJ71QE71N-B2 A1SJ71QE71N-T A1SJ71QE71N-B5T A1SJ71QE71-B5 A1SJ71QE71-B2 A1SJ71E71N3-T A1SJ71E71N-B5 A1SJ71E71N-B2 A1SJ71E71N-T A1SJ71E71N-B5T A1SJ71E71-B5-S3 A1SJ71E71-B2-S3

*1: When using an A-series Ethernet (E71 modules) with QCPU/QnACPU, only the device ranges within AnACPU specifications are supported except for the following devices. · Devices that have been newly added to the QCPU/QnACPU. · Latch relay (L) and step relay (S). (At the QCPU/QnACPU, the latch relay (L) and step relay (S) are separate devices from the internal relay (M), but the internal relay is nonetheless accessed when either the latch relay or step relay is specified.) · File register (R) · Local devices

vFor CC- Link (via G4) connection *1 CPU series MELSEC-Q series (Q mode)

CC-Link unit QJ61BT11 QJ61BT11N

Peripheral device connection unit AJ65BT-G4-S3

*1: The GT11 can monitor only the master station.

29


Connectable model list The GOT1000 series allows connection to Mitsubishi PLCs and a variety of other FA devices.

mModules that can be connected to other brand computer link module

[PLC/motion controller]

Manufacturer

Other brand PLCs/motion controllers Manufacturer

Model name

Computer link connection CPU direct connection

CPM1 CPM2A

Manufacturer

RS-422 RS-232 RS-422 RS-232

CPM1A Micro PLC

@

@ V

FP1-C24C

FP0-C32CT

FP2 FP2SH

V

V

C200HE Small-sized OMRON

PLC

CQM1H

@

V

V

FP10(S) FP-M(C20TC) FP-M(C32TC) GL120 GL130

CJ1G

GL60S

V *1 @

C2000H CV500

PLC

CV1000 CV2000

GL70H Yaskawa Electric

CP-9300MS

@

@

MP-920/930

V *1

MP-940 PROGIC-8

KV-700

CP-9200(H)

V

V

@

V

FA500

JW-21CU JW-31CUH

SHARP

F3SP05

V

@

@

@

F3SP08 F3SP10

JW-22CU

F3SP20

JW-32CUH

F3SP30

JW-70CUH

V

@

V *1

JW-100CUH

FA-M3

JW-100CU Z-512J

@

TOSHIBA

T series

T2N

@

@

T3 model 3000(S3) model 2000(S2)

@

@

@

@ @

F3SP59

V

@

SLC500-30

H-4010(CPU3-40H)

SLC5/02

Allen-Bradley

H-250(CPU21-02H)

(Rockwell)

@

@

V

(Digital CPU) *2

1761-L32BWA 1761-L32BWB

Equipment

H-20DR

1761-L32BBB

Systems

H-28DR

1761-L32AAA

H-40DR

MicroLogix 1000 series (Analogue CPU) *2*3*4

H-64DR

@

@

@

V

HL-64DR

@

V

V

@

@

@

V

RS-485

RS-422

V (2-wire type) V (2-wire type) V (2-wire type) V (2-wire type) V (2-wire type) V (4-wire type) V (4-wire type) V (4-wire type) V (2-wire type) V (2-wire type) V (2-wire type) V (2-wire type) V (2-wire type) @

*1 *1 *1 *1 *1

*1 *1 *1 *1 *1

RS-232

@ @ @ @ @ @ @ @ @ @ @ @ V V

V V V *2 V *2 V *2 V V *2 V V *2 V *2 V *2 V *2 V V

*1:Supported only by the GT15. *2:RS-232/RS-485 conversion adaptor is required.

[Inverter]

@

Inverter V

Manufacturer MITSUBISHI

Set parameters and display alarms when connected to Mitsubishi inverters. Model name FREQROL-S500/E500/A500/F500 FREQROL-A700/F700

RS-422

RS-232

V V

@ @

[Servo amplifier] @

@

@

V

Servo amplifiers Manufacturer

Set parameters and display alarms when connected to Mitsubishi servo amplifiers.

Model name MR-J2S-□A MR-J2S-□CP MR-J2M-P8A MELSERVO-J2M series MR-J2M-□DU MELSERVO-J3 series MR-J3-□A

RS-422

RS-232

V V V V V

V V V V V

MELSERVO-J2-Super series MITSUBISHI

[CNC] @

@

@

V

CNC

1761-L20BWA-5A 1761-L20BWB-5A

SIMATIC S7-300 series

@

@

@

V

*1: RS-422 or RS-232 is selectable. *2: Connection to DH485 network possible via adaptor (1770-KF3). *3: Connection to DH485 requires a "Series-C" or later CPU. ("Series-B" and earlier models do not support the DH485 protocol.) *4: A one-to-one connection requires a "Series-D" or later CPU. ("Series-C" and earlier models do not support the DF1 half-duplex format.)

MELDAS C6/C64 monitoring and parameter settings can be performed.

Series

Model Bus name connection

MELDAS C6/C64

FCA C6 FCA C64

1761-L20AWA-5A

SIMATIC S7-400 series

EH-CPU104

EH-CPU316

RCK

@

SIMATIC S7-200 series SIEMENS

HL-40DR

EH-CPU308

DMC H-PCP-J H-PCP-A,H-PCP-B

V

MicroLogix 1500 series *2 1764-LSP

H-64DT

EH-CPU208

@

MicroLogix 1200 series *2 1762-L24BWA

H-40DT

EH-150 series

SDC

YAMATAKE

Model name E5AN E5EN E5CN E5GN E5ZN SDC20/21 SDC30/31 SDC40A/40B/40G SDC15 SDC25/26 SDC35/36 DMC10

1761-L32AWA

H-252C(CPE22-02HC)

H-28DT

In-Panel NEO

V

1761-L16BBB

H-252C(CPU22-02HC)

board type

V @

1761-L16BWB

Industrial

H-20DT

LC02-0N F3LC11-2N

Yokogawa Electric Personal computer link module

AFP2462 AFP3462 AFP5462 JAMSC-IF60 JAMSC-IF61 CP-217IF LC01-0N LC02-0N F3LC01-1N F3LC11-1N F3LC11-1F F3LC12-1F

1761-L16BWA MicroLogix 1000 series

Hitachi

H series

OMRON

1761-L16AWA

H-200(CPU-02H, CPE-02H)

H-252B(CPU22-02HB)

Thermac NEO

SLC5/05 1761-L10BWB

series

Manufacturer

SLC5/04

V

H-2000(CPU-20Ha)

30

SLC5/01

1761-L10BWA

@

JAMSC-120NOM27100 JAMSC-IF612

Yaskawa Electric Memo bus module

COMM-H COMM-2H

Log data, set parameters, and display alarms when connected to temperature controllers.

@

SLC500-40

H-700(CPU-07Ha)

H-252(CPU22-02H)

Matsushita Electric Works Computer communication unit

RS-232

SLC500-20

H-300(CPU-03Ha)

H200 to 252

@

SLC5/03

@

Hitachi Industrial Equipment Systems Intelligent serial port module

JW-21CM JW-10CM ZW-10CM COMM-H COMM-2H

KV-L20R KV-L20

Temperature controller

@

V

F3SP25

V V

H-1002(CPU2-10H) H series

@

F3SP58

SLC 500 series *2

V *1

KV-L20R KV-L20

KEYENCE

F3SP53

H-702(CPU2-07H) H-2002(CPU2-20H)

V V

F3SP38

H-302(CPU2-03H)

Large-sized

@

@

V*1

V

RS-422

SHARP Link unit

[Temperature controller]

F3SP28

V *1 V *1

T2E

T3H V series

V *1 V

T2(PU224)

@

F3SP21 F3SP35

@

V @ @ V V @

OMRON Upper-level link unit, communication unit, communication board

Manufacturer

C200H-LK201-V1 C500H-LK201-V1 CS1W-SCU21 CS1W-SCB21 CS1W-SCB41 CJ1W-SCU41 C200HW-COM02 C200HW-COM05 C200HW-COM06 CQM1-CIF01 CQM1-CIF02 CQM1-SCB41 CPM1-CIF01 CPM2C-CN111 CPM2C-CIF01-V1

F3FP36

Yokogawa Electric

@

FA500

JW-50CUH

JW-33CUH

PROSEC

CP-9200SH

CVM1 KV-1000

V

GL60H

C1000H Large-sized

@

∑ FP-F

V

CJ1H CJ1M

@

FP10SH

CS1D

KEYENCE

FP3 FP5

@

@ @

Matsushita Electric Works

CS1H CS1G

RS-422 RS-232 RS-422 RS-232 @ @ @ V

RS-232

C200H-LK202-V1 C500H-LK201-V1 CQM1-SCB41 CJ1W-SCU41 CS1W-SCB41 C200HW-COM03 C200HW-COM06

Connectable model list

@

C200HG CQM1

Computer link connection CPU direct connection

FP1-C40C

V

C200HS C200HX

Model name FP0-C16CT

CPM2C C200H

RS-422

Achieve maximum 115.2kbps high-speed communication with other brand PLCs via RS-232 communication. Having an RS-422 converter unit or serial communication unit on the GT15, can be performed RS-422 communication. The GT11 model is embedded with both an RS-422 and RS-422 interface as standard.

@

mModules that can be connected to Mitsubishi CNC

Connection configuration CPU Computer- MELSEC CC-Link CC-Link direct link con- NET/10 (ID) (via G4) Ethernet *1 connection nection *1*2 *1*3

V

*4

@

V *5

V *4

@

V *4

*1: Supported only by the GT15. *2: When MELSECNET/H is used in NET/10 Mode, the GOT terminal cannot be connected directly to a Remote I/O station. *3: CC-Link (ID): Connected as CC-Link (intelligent device station). This is a "Ver.1 intelligent device station" permitting monitoring by transient and cyclic communication. Cyclic communication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the CC-Link master/local unit being used. *4: Use NC system software version D0 or later. *5: Use NC system software version E0 or later.

vFor MELSECNET/10 connection Series MELDAS C6/C64

MELSECNET/H (NET/10 mode), MELSECNET/10 module Optical loop Coaxial bus FCU6-EX879

FCU6-EX878

vFor CC-Link (ID) connection Series MELDAS C6/C64

CC-Link unit FCU6-HR865

vFor Ethernet connection Series MELDAS C6/C64

Ethernet unit FCU6-EX875

31


Connection configuration To achieve optimum performance, select one of the various connection configurations as well as the units to be connected, the distance, and the maximum number of GOT terminals. For connection configuration when using multi-channel function, refer to the "Notes for use" on page 55.

Mitsubishi PLC Bus connection

GT15

Touch switches achieves as quick response as pushbuttons.

Communication interface installed on GOT side

Bus connection unit GT15

GT15-QBUS*2 GT15-QBUS2*2

GT15-75QBUSL*2 GT15-75QBUS2L*2

Connection cable

Bus connection cable

GT15-QC□B GT15-QC□BS

Maximum number of GOTs connected

0 1 2 3 4 5 6 7 8 9 A B C D E F

Maximum number of GOTs connected

3 units

(

2 units AnN,AnS(H),A1SJ(H) 1 unit A0J2HCPU

GT11

36m

QnA/ACPU

RS232

)

GT15

GT15-ABUS*3 GT15-ABUS2*3

GT15-75ABUSL*3 GT15-75ABUS2L*3

when connected with QnACPU type/AnCPU type when connected with QnASCPU type/AnSCPU type

GT15-C□NB GT15-AC□B GT15-A370C□B-S1 GT15-A370C□B GT15-A1SC□B GT15-C□EXSS-1*1 GT15-C□BS

Maximum number of GOTs connected

3 units

32.5m

when connected with A273UCPU/A273UHCPU(-S3) /A373UCPU(-S3): with extension base when connected with A273UCPU/A273UHCPU(-S3) /A373UCPU(-S3): without extension base

33m

when connected with A171SHCPUN/A172SHCPUN/ A173UHCPU(-S1): with extension base

30m

when connected with A171SHCPUN/A172SHCPUN/ A173UHCPU(-S1): without extension base

*1: See the external dimensions information (page 51 and following) for the GT15-C□EXSS-1 cable shape. *2: Use of the Ethernet download and Gateway function requires the GT15-QBus (2). Note that the GT15-75QBus (2) L cannot be used. *3: Use of the Ethernet download and Gateway function requires the GT15-ABus (2). Note that the GT15-75ABus (2) L cannot be used.

CPU direct connection

A series Motion Controller CPU

( 2 units A171SHCPUN A172SHCPUN )

Embedded in GOT

Embedded in GOT

or

Serial communication unit GT15-RS2-9P

RS232

GT15

GT11

GT15

Serial or communication unit GT15-RS2-9P

GT01-C□R2-6P 30: 3m

GT15-RS2T4-9P

RS-422 cable

GT01-C□R4-25P 30: 3m 100: 10m

RS-232/422 conversion cable GT11

Embedded in GOT

GT15

Refer to Bus connection on page 38 and following for details.

RS232

GT15

200: 20m 300: 30m

FA-CNV□CBL*1 2402: 0.2m 2405: 0.5m

or

GT15-RS2T4-9P

Maximum number of GOTs connected

Serial communication unit GT15-RS4-9S

RS-422 cable

1 unit

QCPU Q series Motion Controller CPU MELSECNET/H remote I/O station

GT15

Serial RS-422 or communication converter unit GT15-RS2T4-9P GT15-RS4-9S

GT11

32

POWER RUN BATT.V PROG.E CPU.E

GT11

Maximum number of GOTs connected

1 unit

QCPU Q series Motion Controller CPU MELSECNET/H remote I/O station

GT01-C□R4-8P 10: 1m 30: 3m 100: 10m 200: 20m 300: 30m

Maximum number of GOTs connected

FX series (FX1S, FX1N, FX2N)

1 unit

(RS-422 CPU port) (Function extension board (FX□N-422-BD) for RS-422)

(

2 units when using the function extension board (FX□N-422-BD)

)

GT15

Maximum connection distance 0 1 2 3 4 5 6 7 8 9 A B C D E F

30.5m

Embedded in GOT

or

Serial communication unit GT15-RS2-9P

RS-232 cable

GT01-C□R2-9S 30: 3m

Maximum number of GOTs connected when using function adaptor specified on the right ( 2 units when using RS-422 CPU port )

1 unit

Embedded in GOT

30: 3m

0 1 2 3 4 5 6 7

IN

10 11 12 13 14 15 16 17

FX series (FX1NC, FX2NC) (Function adaptor (FX2NC-232-ADP) for RS-232) (Function adaptor (FX0N-232-ADP) for RS-232) FX0N-232ADP POWER RD SD

Maximum connection distance

15m

Serial RS-422 or communication converter unit GT15-RS2T4-9P GT15-RS4-9S

RS-422 cable

GT01-C□R4-8P 10: 1m 30: 3m 100: 10m 200: 20m 300: 30m

Maximum number of GOTs connected

1 unit

FX series(FX1NC,FX2NC) (RS-422 CPU port)

( 2 units when using RS-232 function adaptor )

FX2NC-16MT

30m

Embedded in GOT

RS-422 converter

or

GT15-RS2T4-9P

Serial communication unit GT15-RS4-9S

RS-422 cable

GT01-C□R4-8P 10: 1m 30: 3m 100: 10m 200: 20m 300: 30m

Maximum number of GOTs connected

1 unit

RS422

FX series(FX0S,FX0N) (RS-422 CPU port)

Maximum connection distance

GT01-C□R4-25P 30: 3m 100: 10m 200: 20m 300: 30m

Maximum number of GOTs connected

1 unit

QnA/ACPU/ A series Motion Controller CPU (CPU port: RS-422)

GT11

GT01-C□R2-9S 30: 3m

Computer link connection

Connects multiple GOTs easily via serial communication (connecting one or two GOTs with one computer link unit).

vQCPU (Q mode) / QnACPU / Q series Motion controller CPU Connection configuration Communication interface installed on GOT side

Embedded in GOT

Serial or communication unit GT15-RS2-9P

GT15-RS2-9P

using the function extension board or 2 units when the function adaptor specified on the right. 3 units ( when using RS-422 CPU port )

FX series (FX3U, FX3UC) (Function extension board (FX3U-232-BD) for RS-232) (Function adaptor (FX3U-232-ADP) for RS-232)*2

Maximum connection distance

Embedded in GOT

4 5 6 7 POWER RUN BATT

OUT

FX3U-16M

RS232

GT11

0 1 2 3

IN

ERROR

15m Fabricated by user when length exceeds 3m.

Connection cable

RS-232 To be fabricated by user. cable D-sub 9 pins (female)

Maximum number of GOTs connected

FX0N-24MR

Embedded in GOT

*2:A Function extension board is required.

GT15

RS-232 cable

0 1 2 3 4 5 6 7

POWER RUN BATT.V PROG.E CPU.E

FX2N-32MR

vFX series(FX0S,FX0N)

Embedded in GOT

Serial communication unit

0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17

Maximum connection distance

vFX series (FX3U, FX3UC) GT15

10 11 12 13 14 15 16 17

IN

Embedded in GOT

*1:This item is developed by Mitsubishi Electric Engineering Company Limited and sold through your local sales office.

RS232

RS-422 cable

RS422

0 1 2 3 4 5 6 7 8 9 A B C D E F

Maximum connection distance

or

0 1 2 3 4 5 6 7

IN

FX2N-32MR

FX2NC-232ADP

Connected to

30m

Embedded in GOT

Maximum connection distance

15m

30m

RS422

GT11

(Function extension board (FX□N-232-BD) for RS-232) (Function adaptor (FX2NC-232-ADP) for RS-232) *2 (Function adaptor (FX0N-232-ADP) for RS-232) *2

30: 3m

GT01-C□R2-25P

GT11

vQnA / ACPU / A series Motion controller CPU RS-422 converter

FX series (FX1S, FX1N, FX2N)

when using the function extension board or the function adaptor specified on the right. ( 2 units when using RS-422 CPU port )

IN

(CPU port: RS-232)

RS422

Maximum number of GOTs connected

1 unit

vFX series(FX1NC,FX2NC)

Maximum connection distance

Serial communication unit GT15-RS4-9S

30: 3m

Maximum connection distance

GT11

3m

or

GT01-C□R2-9S

10 11 12 13 14 15 16 17

(CPU port: RS-232)

Embedded in GOT

RS-422 converter

0 1 2 3 4 5 6 7

Fabricated by user when length exceeds 3m.

Connection cable

RS-232 cable

RS-232 cable

Embedded in GOT

vQCPU / Q series Motion controller CPU Embedded in GOT

RUN

30m

MELSEC-Q/QnA/A/FX series can be connected via CPU direct connection at the lowest cost.

Connection configuration Communication interface installed on GOT side

4 5 6 7 POWER

FX3U-16M

R

RS422

Maximum connection distance

36.6m

0 1 2 3

IN

30m

Fabricated by user when length exceeds 3m.

GT15

Bus connection cable

(RS-422 CPU port) (Function extension board (FX3U-422-BD) for RS-422)

GT01-C□R2-25P

GT11

vA series Motion controller CPU Bus connection unit

( 3 units when using RS-232 CPU port )

FX series (FX3UC, FX3CU)

vFX series (FX1S, FX1N, FX2N)

Maximum connection distance

36.6m

when using the CPU port and the function

Connection configuration

GT15

GT15-C□NB GT15-AC□B GT15-A1SC□B GT15-A1SC□NB GT15-C□EXSS-1*1 GT15-C□BS GT15-J2C□B

Maximum number of GOTs connected

2 units extension board specified on the right.

BATT

Maximum connection distance

Bus connection cable

10: 1m 30: 3m 100: 10m 200: 20m 300: 30m

ERROR

QCPU (Q mode) Q series Motion Controller CPU

5 units

GT01-C□R4-8P

Maximum connection distance

GT15

GT15-75ABUSL*3 GT15-75ABUS2L*3

RS-422 cable

OUT

vQnA/ACPU GT15-ABUS*3 GT15-ABUS2*3

GT15-RS2T4-9P

Serial communication unit GT15-RS4-9S

Connected to

37m

Bus connection unit

or

RS422

vQCPU (Q mode) / Q series Motion controller CPU Connection configuration

RS-422 converter

GT15

Embedded in GOT Embedded in GOT

0 1 2 3 4 5 6 7

Embedded in GOT

( 2 units when QJ71C24N-R2 is used )

or

Serial communication unit GT15-RS2-9P

RS-232 To be fabricated by user. cable D-sub 25 pins (male)

Connected to

QCPU (Q mode) / QnASCPU type Q series Motion Controller MELSECNET/H remote I/O station

Maximum connection distance

15m

D-sub 9 pins (female)

R

GT11

D-sub 9 pins (male)

Maximum number of GOTs connected

1 unit

Maximum number of GOTs connected

1 unit Maximum connection distance

15m

AJ71UC24-S2

0 1 2 3 4 5 6 7 8 9 A B C D E F

Serial communication unit

QnACPU type AJ71UC24-S2

Serial communication unit

33


Connection configuration

RS-422 cable

GT01-C□R4-25P

1 unit

GT15-RS4-9S

GT01-C□R4-25P AJ65BT-G4-S3 30 : 3m 100 : 10m 200 : 20m 300 : 30m

QnACPU type

Maximum number of GOTs connected

30: 3m 200: 20m 100: 10m 300: 30m

GT11

Maximum connection distance *2

(

Embedded in GOT

In the following cases:

1230m

1200m : CC-Link dedicated cable 156Kbps + 30m : RS-422 cable

)

A J61QBT11

0 1 2 3 4 5 6 7 8 9 A B C D E F

78

456

Serial communication unit

Connected to

QCPU (Q mode) Q series Motion controller CPU (RS-232 CPU port)

1 unit

78

ABCD

78 901

GT15-RS2T4-9P

Serial communication unit GT15-RS4-9S

)

Maximum number of GOTs connected

CC-Link dedicated cable

01 EF

or

when A1SJ71UC24-R4 or A1SJ71C24-R4 is used.

Peripheral device connection unit for GPP function

901

GT15

RS-422 converter

( 500m

RS-422 cable

or

GT15-RS2T4-9P

Connection cable

Serial communication unit

901

RS422

1200m

Embedded in GOT

RS-422 converter

456

GT15 0 1 2 3 4 5 6 7 8 9 A B C D E F

Communication interface installed on GOT side

89 67

AJ71UC24-S2

Maximum connection distance

GT11

Connection configuration

( 2 units when QJ71C24N-R4 is used ) D-sub 9 pins (male)

Connectable to CC-Link by way of AJ65BT-G4-S3. *1

CC-Link (via G4) connection

456

QCPU (Q mode) / QnASCPU type Q series Motion Controller CPU MELSECNET/H remote I/O station

Maximum number of GOTs connected

1 unit

23

RS-422 To be fabricated by user. cable

23

GT15-RS2T4-9P

Serial communication unit GT15-RS4-9S

23

or

2345

GT15

RS-422 converter

CC-Link unit

AJ71UC24-S2

Connection configuration

Maximum connection distance

456

78

78

456

100m

A J61QBT11

0 1 2 3 4 5 6 7 8 9 A B C D E F

ABCD

78 901

Maximum segment length

RS232

Ethernet unit

Maximum connection distance

GT11

GT15

Embedded in GOT

D-sub 9 pins (female)

D-sub 25 pins (male)

15m

Other brand PLC

AJ71UC24-S2

Serial or communication unit GT15-RS2T4-9P GT15-RS4-9S

RS-422 converter

RS422

RS-422 To be fabricated by user. cable

Computer link unit

Maximum number of GOTs connected

Connection to other brand PLC Connection configuration

1 unit

D-sub 9 pins (male)

GT15

Maximum connection distance

500m GT11

Connection configuration Communication interface installed on GOT side

GT15

Optical loop

MELSECNET/10 communication unit

Connection cable

Fiber-optic cable

Maximum number of GOTs connected

Fiber-optic cable

Connected to

QCPU QnA/ACPU (Control station/normal station)/ A series Motion Controller CPU

63 units Maximum connection distance

GT15-75J71LP23-Z(Optical loop) GT15-75J71BR13-Z(Coaxial bus)

*2 With QSI optical cable, maximum distance between stations is 1km

(

)

GT15

0 1 2 3 4 5 6 7 8 9 A B C D E F

456

23 456

901

23 89 67

01 EF

GT11

2345

456

901

23

31 units

78

78

ABCD

78

(

)

QCPU QnA/ACPU (Master/local station) A series Motion Controller CPU

Maximum connection distance

GT11

Embedded in GOT

Serial or communication unit GT15-RS2-9P

Connection cable

RS-232 To be fabricated by user. cable D-sub 9 pins (female)

Embedded in GOT

Depending on the PLC CPU specifications to which the GOT is connected.

other brand PLC CPUs

Maximum connection distance

· OMRON · KEYENCE · SHARP · TOSHIBA · Hitachi Industrial Equipment Systems · YASKAWA Electric · YOKOGAWA Electric

POWER

0 1 2 3 4 5 6 7 8 9 A B C D E F

456

78

78

456

For details, refer to the "Connectable model list" on page 30.

Maximum number of GOTs connected

1 unit

01 EF

ABCD

78

Connected to

Microcomputer board, personal computer, PLC, etc.

Maximum connection distance Depending on the specifications of the host side personal computer, microcomputer board, PLC, etc.

901 901

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 1 2 3 4 5 6 7 8 9 A B C D E F

Connects microcomputer board or personal computer to the GOTs.

901

(For CC-Link dedicated cable at 156kbps: 1200m )

GT15

RS232

A J61QBT11

89 67

*2

POWER

Microcomputer

Connected to

456

(For intelligent device station)

Embedded in GOT

· OMRON · KEYENCE · SHARP · TOSHIBA · Hitachi Industrial Equipment Systems · Matsushita Electric Works · YASKAWA Electric · YOKOGAWA Electric · Allen-Bradley (Rockwell Automation) · SIEMENS

Maximum number of GOTs connected Compatible with the following

1 unit Depending on the PLC CPU specifications to which the GOT is connected.

23

26 units

Maximum connection distance Depending on the PLC CPU specifications to which the GOT is connected.

Depending on the PLC CPU specifications to which the GOT is connected.

Connection configuration Communication interface installed on GOT side

Maximum number of GOTs connected

(When transient transmitting suggested 5 or less GOTs)

Connection cable to other brand PLC*1

23

GT15-75J61BT13-Z

CC-Link dedicated cable

RS-422 cable

23

CC-Link communication unit

GT15-RS2T4-9P

Serial communication unit GT15-RS4-9S

2345

GT15

Connection cable

or

Microcomputer connection

Connects CC-Link system as intelligent device station.*1

Connection configuration Communication interface installed on GOT side

RS-422 converter

Connected to

Compatible with the following other brand PLC CPUs

1 unit

*1: This item is developed by Mitsubishi Electric Engineering Company Limited and sold through your local sales office.

*1: MELSECNET/H is also used in NET/10 mode. *2: The maximum total extension length and distance between stations vary according to the number of stations and the cable type being used. For details, refer to the MELSECNET/H and MELSECNET/10 Reference Manuals.

CC-Link (ID) connection

Depending on the PLC CPU specifications to which the GOT is connected.

Maximum number of GOTs connected

Network unit

Maximum connection distance *2 With 5C-2V coaxial cable, maximum distance between stations is 500m 500m

Connection cable Connection cable to other brand PLC*1

RS-232 cable

Embedded in GOT

RS422

901

GT15

Coaxial bus

Maximum number of GOTs connected

Coaxial cable

Serial or communication unit GT15-RS2-9P

D-sub 9 pins (male)

A J61QBT11

Coaxial cable

Embedded in GOT

D-sub 9 pins (female)

GT11

Allows multiple GOTs to be used as remote control terminals. (Connectable as MELSECNET/10*1 normal stations.)

Supporting other brand PLC CPU

Communication interface installed on GOT side

RS232

Embedded in GOT

MELSECNET/10 Connection (PC-to-PC Network)

Q25HCPU Q61P-A1

CC-Link unit GT15

RS-422 converter GT15-RS2T4-9P

RS422

or

Serial communication unit GT15-RS4-9S

RS-422 To be fabricated by user. cable

MODE RUN ERR USER BAT BOOT

D-sub 9 pins (male)

GT11

Embedded in GOT

Depending on the PLC CPU specifications to which the GOT is connected.

PULL

Maximum number of GOTs connected

QX10

QX41

POWER

PULL

USB

*1: This is a "Ver.1 intelligent device station". Monitoring is possible via transient or cyclic communication. Cyclic communication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the CC-Link master/local unit being used. *2: The maximum cable extension length and cable lengths between stations vary according to the type of cable being used and the transmission speed.

34

(Suggested less than 16 GOTs)

89 67

1 unit

D-sub 9 pins (male)

GT15

Connected to

QCPU QnA/ACPU A series Motion Controller CPU

01 EF

D-sub 9 pins (female)

QCPU (A mode) / ACPU / A series Motion Controller CPU

Maximum number of GOTs connected

Maximum number of GOTs connected

128 units

456

RS-232 To be fabricated by user. cable

10BASE-T cable 100BASE-TX cable

901

Serial communication unit GT15-RS2-9P

Connection cable

Ethernet cable

23

or

Ethernet communication unit GT15-J71E71-100

901

GT15

Embedded in GOT

Communication interface installed on GOT side

23

vQCPU (A mode) / ACPU / A series Motion controller CPU

Machines on the production floor can be easily accessed from a remote location (Remote Maintenance) when GOT terminals are fitted with an Ethernet interface.

Ethernet connection

23

when AJ71UC24 is used )

2345

Serial communication unit

Connection configuration

GT11

1200m ( 500m

D-sub 9 pins (male)

Embedded in GOT

*1: GT11 can only monitor the master station. *2: The maximum cable extension length and cable lengths between stations vary according to the type of cable being used and the transmission speed. For details, refer to the user's manual for the CC-Link master/local unit being used.

Maximum connection distance

Fabricated by user when length exceeds 30m.

QX41

QJ71BR11 RUN T.PASS SD ERR

QJ71BR11 MNG D.LINK RD ERR

RUN T.PASS SD ERR

MNG D.LINK RD ERR

0 1 2 3 4 5 6 7 8 9 A B C D E F

1 unit

Maximum connection distance Depending on the specifications of the host side personal computer, microcomputer board, PLC, etc.

35


Connection configuration

Temperature controller

CNC

Temperature controller connection Connection configuration Communication interface installed on GOT side

GT15

Embedded in GOT

or

Serial communication unit GT15-RS2-9P

RS232

Log data, set parameters, and display alarms when connected to temperature controllers. Connection cable

RS-232 cable

*1 Depending on the PLC CPU specifications to which the GOT is connected.

CPU direct connection

· OMRON · YAMATAKE · RKC

GT15

RS232

Maximum connection distance

Serial or communication unit GT15-RS2T4-9P GT15-RS4-9S

RS422

RS-422 cable

*1

Maximum number of GOTs connected

GT15

GT15

· RKC

1 unit Depending on the PLC CPU specifications to which the GOT is connected.

D-sub 9 pins (male)

GT11

Temperature controller

Connection cable

*1 GT11

Maximum connection distance

Embedded in GOT RS-422 converter

Serial Serial communication or communication unit unit GT15-RS4-9S GT15-RS4-TE

RS-485 (4-wire type) cable

*1

Maximum number of GOTs connected Depending on the PLC CPU specifications to which the GOT is connected.

D-sub 9 pins (male)

[4-wire type]

3m

or

GT15-RS2T4-9P

Serial communication unit GT15-RS4-9S

RS-422 GT01-C□R4-25P 30: 3m cable 100: 10m

30.5m

Embedded in GOT

F311 cable

· YAMATAKE

1 unit

Allows multiple GOTs to be used as remote control terminals. (Connectable as MELSECNET/10*1 normal stations.)

Connection configuration Communication interface installed on GOT side

Optical loop

GT15

MELSECNET/10 communication unit

Connection cable

Maximum number of GOTs connected

Fiber-optic cable

Fiber-optic cable

Maximum connection distance *2 With QSI optical cable, maximum distance between stations is 1km

(

GT15-75J71LP23-Z(Optical loop) GT15-75J71BR13-Z(Coaxial bus)

Serial communication unit GT15-RS4-TE

RS-485 (2-wire type) cable Terminal block

*1 Depending on the PLC CPU specifications to which the GOT is connected.

Maximum number of GOTs connected

Temperature controller

1 unit

· OMRON · YAMATAKE · RKC

31 units

(

Connects CC-Link system as intelligent device station.*1

CC-Link (ID) connection

Connection configuration Communication interface installed on GOT side

Inverter

GT15-75J61BT13-Z CC-Link communication (For intelligent device station) unit

GT15

Connection cable

Maximum number of GOTs connected

RS422

Connection cable

RS-422 cable

*1

D-sub 9 pins (male)

Maximum number of GOTs connected

1 unit Depending on the PLC CPU specifications to which the GOT is connected.

(When transient transmitting suggested 5 or less GOTs)

Maximum connection distance

Inverter

*1: This is a "Ver.1 intelligent device station". Monitoring is possible via transient or cyclic communication. Cycliccommunication restrictions exist, however, in the remote net Ver.2 mode, and in the remote net added mode. For details, refer to the user's manual for the MELDAS C6/C64 being used. *2: The maximum cable extension length and cable lengths between stations vary according to the type of cable being used and the transmission speed. *3: Use NC system software version D0 or later. FR-DU04

MON

Maximum connection distance

CONTROL PANEL Hz A V EXT REV

PU FWD

Ethernet connection

Machines on the production floor can be easily accessed from a remote location (Remote Maintenance) when GOT terminals are fitted with an Ethernet interface.

Connection configuration Communication interface installed on GOT side

When connecting inverters in multi-drop connection: Max. extension length is 500m

)

Ethernet communication unit

GT15

GT15-J71E71-100

Connection cable

Ethernet cable

Maximum number of GOTs connected

Maximum connection distance Maximum segment length

Servo amplifier Connection cable

RS-232 cable

*1

D-sub 9 pins (female)

Maximum number of GOTs connected

1 unit Depending on the PLC CPU specifications to which the GOT is connected.

Maximum connection distance *1 When using MELSERVO-J2-Super

15m

GT15

Serial communication unit GT15-RS2T4-9P GT15-RS4-9S

RS-422 cable

*1

D-sub 9 pins (male)

RS422

GT11

36

or

Embedded in GOT

Depending on the PLC CPU specifications to which the GOT is connected.

Connected to

Multiple unit connections (GT11)

Servo amplifier MELSERVO-J2-Super series MELSERVO-J2M series MELSERVO-J3 series

Extension unit

2

units

• The transparent function is not available when multiple units are connected. • Multiple units cannot be connected using the USB interface.

*1

A/QnACPU IN

0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17

POWER RUN BATT.V PROG.E CPU.E

FX2N-32MR

L1

L2

L3

U

V

W

Servo amplifier

1 unit

MELSERVO-J2-Super series MELSERVO-J2M series MELSERVO-J3 series

IN

0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17

RS-422

1

30m

RS-232

QJ71C24, QJ71C24N, QJ71C24N-R4 FX1S/FX1NCPU or FX1S+FX1N-422BD/FX1N+FX1N-422BD FX2NCPU or FX2N+FX2N-422BD FX1NC / FX2NCCPU FX3UCPU or FX3U+FX3U-422BD FX3UCCPU or FX3UC+FX3U-422BD

2

15m

*1: Handy GOT can only be connected as the second device.

When the first device is connected via RS-232 connection *1 When connecting MELSERVO-J2 in multi-drop connection: Max. extension length is 30m

number

Connected PLCs

When the first device is connected via RS-422 connection

OPEN

Maximum number of GOTs connected

Maximum connection distance

m

GOTs of

Serial or communication unit GT15-RS2-9P

When connected directly to Mitsubishi PLC and CPU

Maximu

Up to 32 axes can be controlled when multiple servo amplifiers are connected in multi-drop connection, with capabilities for parameter setting and alarm display.

Connection configuration Communication interface installed on GOT side

RS-422 converter

100m

*1: Use NC system software version D0 or later.

Servo amplifier connection

RS232

Connected to

128 units (Suggested less than 16 GOTs) MELDAS C6/C64 *1

10BASE-T cable 100BASE-TX cable

*1: The cable and devices vary according to the inverter type. For details, refer to the GOT1000 Series Connection Manual.

Embedded in GOT

Extension unit

at 156kbps: 1200m )

FREQROL500 series FREQROL700 series

(

*2 (For CC-Link dedicated cable

Connected to

500m Embedded in GOT

Connected to

MELDAS C6/C64 *3

26 units

CC-Link dedicated cable

Up to 10 inverters can be connected in multi-drop connection with capabilities for parameter setting and alarm display.

Serial RS-422 or communication converter unit GT15-RS2T4-9P GT15-RS4-9S

)

*1: MELSECNET/H is also used in NET/10 mode. *2: The maximum total extension length and distance between stations vary according to the number of stations and the cable type being used. For details, refer to the MELDAS C6/C64 Reference Manuals. *3: Use NC system software version E0 or later.

*1: The number of connected temperature controllers, the maximum connection distance, and the cable and devices vary according to the temperature controller type. For details, refer to the GOT1000 Series Connection Manual.

Connection configuration Communication interface installed on GOT side

Extension unit

Maximum connection distance *2 With 5C-2V coaxial cable, maximum distance between stations is 500m

*1

Inverter connection

)

Maximum number of GOTs connected

Coaxial cable

Coaxial cable

GT15

Coaxial bus

Connected to

MELDAS C6/C64 *3

63 units

Terminal block

Embedded in GOT

[2-wire type]

GT15

MELDAS C6/C64 *1

Maximum number of GOTs connected

1 unit

200: 20m 300: 30m

MELSECNET/10 Connection (PC-to-PC Network)

Temperature controller

Maximum connection distance

GT11

Connected to

MELDAS C6/C64 *1

1 unit

*1: Use NC system software version D0 or later.

Maximum connection distance

GT15

Maximum number of GOTs connected

RS-232 To be fabricated by user. cable

Maximum connection distance

Maximum connection distance

*1

GT15

Serial or communication unit GT15-RS2-9P

RS422

Embedded in GOT

RS485

GT11

Embedded in GOT

Connection configuration

GT15

GT11

Embedded in GOT RS-422 converter

MELDAS C6/C64 monitoring and parameter settings can be performed.

Connection configuration Communication interface installed on GOT side

Temperature controller

1 unit

D-sub 9 pins (female)

Connected to

*1

GT11

RS485

Maximum number of GOTs connected

*1

OPEN

IN

0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17

POWER RUN BATT.V PROG.E CPU.E

FX2N-32MR

L1

L2

L3

U

V

W

*1: The number of connected servo units, the maximum connection distance, and the cable and devices vary according to the servo type. For details, refer to the GOT1000 Series Connection Manual.

IN

0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17

RS-232

1

RS-422

15m 30m *1: Handy GOT can only be connected as the second device.

2

Connected PLCs QCPU QJ71C24, QJ71C24N, QJ71C24-R2, QJ71C24N-R4 FX1S+FX1N-232BD / FX1N+FX1N-232BD or FX1S+FX2NC-232ADP / FX1N+FX2NC-232ADP*2 FX2N+FX2N-232BD or FX2N+FX2NC-232ADP*2 FX1NC+FX2NC-232ADP / FX2NC+FX2NC-232ADP FX3U+FX3U-232BD or FX3U+FX3U-232ADP*2 FX3UC+FX3U-232BD or FX3UC+FX3U-232ADP*2

RS-422 cable

1

GT01-C30R4-25P (3m) GT01-C100R4-25P (10m) GT01-C200R4-25P (20m) GT01-C300R4-25P (30m) Fabricated by user. GT01-C10R4-8P (1m) GT01-C30R4-8P (3m) GT01-C100R4-8P (10m) GT01-C200R4-8P (20m) GT01-C300R4-8P (30m)

RS-232 cable

1

RS-232 cable

2

GT01-C30R2-9S (3m)

RS-422 cable

2

GT01-C30R2-6P (3m) Fabricated by user. Fabricated by user. GT01-C30R2-9S (3m)

*2: Function extension board is required.

37


Bus connection 1 Bus connection is one of the simplest methods to connect one or even multiple GOT's using extension connectors of the base unit. This connection method provides high performance as well as the fastest response time to Mitsubishi controllers. This solution allows multiple GOTs terminals to be located when computer link (C24) is not desired. Refer to Notes for bus connection on page 46.

GOT connection conditions Installation distance of the first unit from main base *1

Number of GOTs

um axim nu M

5

units

For connectable CPU models, refer to "Connectable mode list" on page 28.

d

When connected with QCPU (Q mode) Q series Motion controller CPU

connecte Ts

er of GO mb

System configuration

Bus extension connector box

Connection distance 0m

37m

13.2m

PLC Main base

GOT

PLC Extension base

1

1

Cable

2

*4

*2

GT15-QC B

1

GOT

06 : 0.6m 12 : 1.2m 30 : 3m 50 : 5m 100: 10m

Middle GOT

2~4

Cable

3

*4

GOT main unit

Bus connection unit

15" type GT1595

GT15-75QBUSL GT15-75QBUS2L GT15-QBUS GT15-QBUS2

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

Last GOT

2~5

*4

GOT main unit

Bus connection unit

15" type GT1595

GT15-75QBUS2L GT15-QBUS2

GOT main unit

Bus connection unit

15" type GT1595

GT15-75QBUSL GT15-75QBUS2L GT15-QBUS GT15-QBUS2

Bus connection

Within 13.2m

Cable

8.4" type GT1565 Cable

Max. 13.2m

1

*1

1 unit PLC Main base

8.4" type GT1562

Bus extension connector box

PLC Extension base

*2

GOT

More than 13.2m Cable

Max. 37m

PLC Main base

Within 13.2m

GOT

PLC Extension base

Max. 13.2m

Middle GOT

Cable

PLC Main base *5

06 : 0.6m 12 : 1.2m 30 : 3m 50 : 5m 100: 10m

1

2~4

Last GOT

2

Cable

GT15-QC B

2~5

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-QC BS

8.4" type GT1565

150 : 15m 200 : 20m 250 : 25m 300 : 30m 350 : 35m

8.4" type GT1562

GT15-QC B 06 : 0.6m 12 : 1.2m 30 : 3m 50 : 5m 100: 10m

3

GT15-75QBUSL GT15-75QBUS2L GT15-QBUS GT15-QBUS2

15" type GT1595 12.1" type GT1585

GT15-75QBUS2L GT15-QBUS2

10.4" type GT1575 10.4" type GT1572

Bus extension connector box

More than 13.2m

PLC Extension base

GOT

Middle GOT

2~4

Last GOT

2~5

A9GT-QCNB

*2

Cable

1

Cable

Max. 37m

2

Cable

3

*3

GT15-QC B 06 : 0.6m 12 : 1.2m 30 : 3m 50 : 5m 100: 10m

06 : 0.6m 12 : 1.2m 30 : 3m 50 : 5m 100: 10m

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-QC B 06 : 0.6m 12 : 1.2m 30 : 3m 50 : 5m 100: 10m

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-QC BS

8.4" type GT1565

GT15-QC BS

8.4" type GT1565

8.4" type GT1562

150 : 15m 200 : 20m 250 : 25m 300 : 30m 350 : 35m

8.4" type GT1562

150 : 15m 200 : 20m 250 : 25m 300 : 30m 350 : 35m

8.4" type GT1562

*3

1

GT15-QC B

8.4" type GT1565

*1

Max. 37m

2 to 5 units

A9GT-QCNB

*3

1

1

Cable

1

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-75QBUS2L GT15-QBUS2

GT15-QC B 06 : 0.6m 12 : 1.2m 30 : 3m 50 : 5m 100: 10m

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-75QBUS2L GT15-QBUS2

GT15-QC B 06 : 0.6m 12 : 1.2m 30 : 3m 50 : 5m 100: 10m

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-QC BS

8.4" type GT1565

GT15-QC BS

8.4" type GT1565

GT15-QC BS

8.4" type GT1565

150 : 15m 200 : 20m 250 : 25m 300 : 30m 350 : 35m

8.4" type GT1562

150 : 15m 200 : 20m

8.4" type GT1562

150 : 15m 200 : 20m

8.4" type GT1562

GT15-75QBUSL GT15-75QBUS2L GT15-QBUS GT15-QBUS2

*1: Includes the extension cable length (between base units) when an extension base unit is used. For cable details between main base and extension bese, refer to the MELSEC-Q catalog (L (NA) 08033E-A). *2: A bus extension connector box is required if the first GOT is installed at a distance of 13.2m or more. If an extension base unit is not being used, install the bus extension connector box at the main base unit. If an extension base unit is being used, install the bus extension connector box at the extension base unit of the stage that precedes the GOT. (When connected to a Q00JCPU, the box installation at the main base unit is not possible. In this case, install it at the extension base unit.) *3: Select cables whose total cable length is 37m or less from the PLC's main base unit to the last GOT. *4: How to read cable type names, for example, QC B 06: 0.6m is GT15-QC06B. *5: When 3 or more GOTs are connected, the following restrictions may be applied, depending on the total cable length: The PLC and all GOTs must have the same power supply and must be switched ON and OFF simultaneously

○: Restriction not applied #: Restriction applied

Number of GOTs 2 or less 3 4 5

38

Within 15m

○ ○ ○ ○

Total cable length Within 20m Within 25m

○ ○ ○ #

○ ○ # #

Within 37m

○ # # #

39


Bus connection 2

Number of GOTs

Installation distance of the first unit from main base *1

When CPUs other than that shown at left is connected

System configuration

Cable

0m

A4UCPU

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

AJ71BR11

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

Bus connector conversion box

Cable

1

*5

GOT

GOT

1 unit

PLC Main base A62P

A4UCPU

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

AJ71BR11

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

AJ71BR11

1

12 : 1.2m 30 : 3m 50 : 5m

Cable

Max. 6.6m

PLC Main base A4UCPU

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

AJ71BR11

Bus connector conversion box

GOT

0

Cable

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

1

GT15-AC B

A7GT-CNB

06 : 0.6m 12 : 1.2m 30 : 3m 50 : 5m

GT15-C EXSS-1*4 100 : 10m 200 : 20m 300 : 30m

GOT main unit

Bus connection unit

15" type GT1595

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

12.1" type GT1585 10.4" type GT1575

15" type GT1595 12.1" type GT1585

Cable

10.4" type GT1575

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

AJ71BR11

PLC Extension base A62P

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

GOT

1

GOT

GT15-C NB

2

1

Cable

12 : 1.2m 30 : 3m 50 : 5m

2

15" type GT1595 12.1" type GT1585

GT15-75ABUS2L GT15-ABUS2

10.4" type GT1575 8.4" type GT1565

Cable

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m 300 : 30m

Bus connector conversion box

GOT

1

GOT

2

0

Cable

1

Cable

GT15-AC B 06 : 0.6m 12 : 1.2m 30 : 3m 50 : 5m

A7GT-CNB

GT15-C EXSS-1*4 100 : 10m 200 : 20m

15" type GT1595 12.1" type GT1585

GT15-75ABUS2L GT15-ABUS2

10.4" type GT1575 10.4" type GT1572 8.4" type GT1565

2

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

8.4" type GT1562 *1

PLC Main base A4UCPU

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

AJ71BR11

PLC Extension base A62P

AX10

AX10

AX10

AX10

AY11

AY11

AJ71BR11

GOT

1

GOT

2

GOT

3

GT15-C NB 12 : 1.2m 30 : 3m 50 : 5m

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

1

Cable

2

Cable

3

8.4" type GT1565 8.4" type GT1562

Max. 6.6m

10.4" type GT1575 10.4" type GT1572

15" type GT1595

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

8.4" type GT1565 8.4" type GT1562

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

8.4" type GT1565 8.4" type GT1562

*3

AJ71BR11

Cable

12.1" type GT1585

Max. 30m Max. 36.6m

A62P

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

Bus connection unit

*3

AJ71BR11

Max. 6.6m

15" type GT1595

GOT main unit

Max. 30m

*2

More than 6.6m

Bus connection unit

*3

*1

2 units A4UCPU

GOT main unit

Max. 30m

Max. 36.6m

A62P

*5

8.4" type GT1565

8.4" type GT1562

PLC Main base

3

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

10.4" type GT1572

Max. 6.6m

GOT

10.4" type GT1572

1

AJ71BR11

Within 6.6m

3

8.4" type GT1562

*1

PLC Extension base A62P

Cable

8.4" type GT1562

Max. 36.6m

A62P

2

8.4" type GT1565

1

*2

More than 6.6m

GOT

*1

PLC Extension base A62P

2

Bus connection

Max. 6.6m

Cable

*5

10.4" type GT1572 Cable

1

*5

AJ71BR11

Within 6.6m

Within 6.6m

For connectable CPU models, refer to "Connectable mode list" on page 28.

GT15-C NB

PLC Extension base A62P

2

units

36.6m

6.6m

PLC Main base A62P

3 units

0

Connection distance

mum nu axi M

mum n axi u M

3

units

d

GOT connection condition

When QnA, AnU, or AnA is connected

d

AnCPU type

er of GO mb

connecte Ts

When connected with QnACPU type

connecte Ts

er of GO mb

*1

Max. 30m

GT15-75ABUS2L GT15-ABUS2

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572 8.4" type GT1565 8.4" type GT1562

GT15-75ABUS2L GT15-ABUS2

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572 8.4" type GT1565 8.4" type GT1562

*6

Max. 36.6m *1: Includes the extension cable length (between base units) when an extension base unit is used. For the cables between base unit and extension base unit, refer to the MELSEC-QnA/A catalog (L-174-0-C5177-B NA-0109). *2: A bus connector conversion box is required if the first GOT is installed at a distance of 6.6m or more. *3: Select cables so that the total cable length is 36.6m from the PLC's main base unit to the last GOT. *4: GT15-C EXSS-1: • Comprises the GT15-EXCNB (0.5m) and the GT15-C BS (10 to 30m). • Calculate cable lengths as follows: GT15-C100EXSS-1: 10m GT15-C200EXSS-1: 20m GT15-C300EXSS-1: 30m *5: Cable length can be read from cable model name. For example, "GT15-AC06B" is 0.6m long. *6: Select cables so that the total cable length does not exceed 30m.

40

41


Bus connection 3

Number of GOTs

Installation distance of the first unit from main base

System configuration

Cable

Connection distance 0m GOT

PLC Main base A1S62P

A2USCPU

A1SP60

A1SP60

A1SP60

A1SH42

*5

30m

5m

0

35m

3

units

Bus connector conversion box

RUN

L.CLR

ERROR

RESET

1

2

units

For connectable CPU models, refer to "Connectable mode list" on page 28.

GOT

1

Cable

2

*5

1

GOT

2

Cable

3

*5

GOT main unit

Bus connection unit

15" type GT1595

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GOT

3

*5

GOT main unit

Bus connection unit

15" type GT1595

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

GOT main unit

Bus connection unit

15" type GT1595

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

Bus connection

07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m

A1SH42

RUN

Cable

1

GT15-A1SC B

RESET

Within 5m

Cable

*1

STOP POWER

When A1SJ(H) or AnS(H) CPU is connected

mum nu axi M

mum n axi u M

When QnAS or A2US(H) is connected

d

GOT connection conditions

Without extension base unit

d

AnSCPU type

er of GO mb

connecte Ts

When connected with QnASCPU type

connecte Ts

er of GO mb

8.4" type GT1565 8.4" type GT1562

Max. 5m GOT

PLC Main base A1S62P

A2USCPU

A1SP60

A1SP60

A1SP60

A1SH42

GT15-C EXSS-1 *4

1

100 : 10m 200 : 20m 300 : 30m

A1SH42

STOP POWER

1 unit

RUN

L.CLR

ERROR

RESET

RUN RESET

More than 5 m Within 35 m

15" type GT1595 12.1" type GT1585 10.4" type GT1575

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

10.4" type GT1572 Cable

1

8.4" type GT1565 8.4" type GT1562

Max. 30m

Bus connector conversion box

PLC Main base A1S62P

A2USCPU

A1SP60

A1SP60

A1SP60

A1SH42

GOT

1

RUN

L.CLR

ERROR

RESET

RUN

*1

RESET

More than 5 m Within 35 m

Cable

0 *2

Max. 35m GOT

PLC Main base A2USCPU

A1SP60

A1SP60

A1SP60

A1SH42

A7GT-CNB

100 : 10m 200 : 20m 300 : 30m

RUN

L.CLR

ERROR

RESET

8.4" type GT1562

1

GOT

2

GT15-A1SC B 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m

A1SH42

RUN

Cable

1

GOT

A1S62P

A2USCPU

2 units

RUN

L.CLR

ERROR

RESET

A1SP60

A1SP60

A1SP60

A1SH42

10.4" type GT1575 10.4" type GT1572 8.4" type GT1565

Max. 30m

8.4" type GT1562

1

GOT

GT15-C EXSS-1 *4

2

100 : 10m 200 : 20m

A1SH42

15" type GT1595 12.1" type GT1585

GT15-75ABUS2L GT15-ABUS2

10.4" type GT1575

STOP POWER

RUN RESET

More than 5m

GT15-75ABUS2L GT15-ABUS2

10.4" type GT1572 Cable

1

Cable

Max. 30m

A2USCPU

A1SP60

A1SP60

A1SP60

A1SH42

8.4" type GT1565

2

RUN

L.CLR

ERROR

RESET

GOT

1

GOT

2

*1

More than 5 m Within 35 m

Cable

GT15-A1SC NB

A7GT-CNB

05 : 0.45m 07 : 0.7m 30 : 3m 50 : 5m

A1SH42

RUN RESET

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572 8.4" type GT1565 8.4" type GT1562

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

8.4" type GT1565 8.4" type GT1562

*3

STOP POWER

07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m 300 : 30m

8.4" type GT1562

Bus connector conversion box

PLC Main base A1S62P

GT15-C BS

*2

Max. 35m PLC Main base

15" type GT1595 12.1" type GT1585

2

Cable

Max. 5m

10.4" type GT1575

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

8.4" type GT1565

Max. 30m

RESET

Within 5m

15" type GT1595 12.1" type GT1585 10.4" type GT1572

STOP POWER

GT15-C EXSS-1 *4

1

Cable

Max. 5m

A1S62P

GT15-A1SC NB 05 : 0.45m 07 : 0.7m 30 : 3m 50 : 5m

A1SH42

STOP POWER

0

Cable

1

Cable

Max. 30m

Max. 5m

GT15-C EXSS-1 *4 100 : 10m 200 : 20m

15" type GT1595 12.1" type GT1585

GT15-75ABUS2L GT15-ABUS2

10.4" type GT1575 10.4" type GT1572

2

8.4" type GT1565

*3

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

8.4" type GT1565 8.4" type GT1562

8.4" type GT1562

Max. 35m GOT

PLC Main base A1S62P

A2USCPU

A1SP60

A1SP60

A1SP60

A1SH42

1

GOT

2

GOT

3

3 units

Within 5m

RUN

L.CLR

ERROR

RESET

RUN RESET

Cable

GT15-A1SC B 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m

A1SH42

STOP POWER

1

Cable

2

Max. 5m

Cable

Max. 30m

3

*3

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572 8.4" type GT1565 8.4" type GT1562

GT15-75ABUS2L GT15-ABUS2

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572 8.4" type GT1565 8.4" type GT1562

GT15-75ABUS2L GT15-ABUS2

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572 8.4" type GT1565 8.4" type GT1562

Max. 35m

42

*1: A bus connector conversion box is required if only one GOT is connected at a distance of 30m or more. *2: Select cables so that the total cable length is 35m or less from the PLC's main base unit to the last GOT. *3: Select cables so that the total cable length does not exceed 30m.

*4: GT15-C EXSS-1: • Comprises the GT15-EXCNB (0.5m) and the GT15-C BS (10 to 30m). • Calculate cable lengths as follows: GT15-C100EXSS-1 (10m), GT15-C200EXSS-1 (20m), GT15-C300EXSS-1 (30m). *5: Cable length can be read from cable model name. For example, "GT15-A1SC NB" is 0.45m long.

43


Bus connection 4

Number of GOTs

Installation distance of the first unit from main base

System configuration

Cable

Connection distance 0m

A1S62P

GOT

PLC Main base

*5

07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m

GOT

1

GT15-C EXSS-1 *4 100 : 10m 200 : 20m 300 : 30m

1 unit Max. 36m

POWER

Cable

*1*3

0

Cable

Max. 36m

1

GOT

PLC Main base

*1*3

GT15-A1SC NB

A7GT-CNB

05 : 0.45m 07 : 0.7m 30 : 3m 50 : 5m

GT15-C EXSS-1 *4 100 : 10m 200 : 20m 300 : 30m

mum nu axi M

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GOT

2

GT15-A1SC B 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m

1

Cable

*1 *1*3

10.4" type GT1575

15" type GT1595 12.1" type GT1585 10.4" type GT1575

15" type GT1595 12.1" type GT1585

GT15-75ABUS2L GT15-ABUS2

10.4" type GT1575 10.4" type GT1572 8.4" type GT1562

1

GOT

2

GT15-C EXSS-1 *4 100 : 10m 200 : 20m

POWER

2 units

Cable

Max. 36m

15" type GT1595 12.1" type GT1585

GT15-75ABUS2L GT15-ABUS2

POWER

2

8.4" type GT1565

0

1

GOT

2

PLC Extension base

1

*1

GOT

PLC Main base

GT15-A1SC NB

A7GT-CNB

05 : 0.45m 07 : 0.7m 30 : 3m 50 : 5m

Cable

*1

1

Cable

Max. 30m

GOT

GOT

3

*5

GOT main unit

Bus connection unit

15" type GT1595

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

GOT main unit

Bus connection unit

100 : 10m 200 : 20m

1

Cable

*1

Max. 30m

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

3

GT15-A1SC B

3

*6

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572 8.4" type GT1565

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

15" type GT1595

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

8.4" type GT1565 8.4" type GT1562

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

8.4" type GT1565

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

8.4" type GT1565 8.4" type GT1562

8.4" type GT1562

GOT

Cable

GT15-75ABUS2L GT15-ABUS2

10.4" type GT1572

*6

2

2

15" type GT1595 12.1" type GT1585 10.4" type GT1575

07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m

Cable

07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m 300 : 30m

8.4" type GT1562

8.4" type GT1565

POWER

Max. 6m

GT15-C EXSS-1 *4

2

A1SP60

Within 6m

GT15-C BS

8.4" type GT1562

Max. 30m

GOT

Max. 36m

3 units

Cable

*2

Max. 6m

POWER

*1*3

Bus connector conversion box

PLC Main base

Cable

A1S62P

1

10.4" type GT1572

A1SP60

POWER

3

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

10.4" type GT1575

A1S62P

Cable

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

8.4" type GT1565

Max. 30m

GOT

PLC Main base

2

A1SP60

PLC Extension base

2

8.4" type GT1562

Max. 30m

1

Max. 36m

More than 6m

GOT

8.4" type GT1565

POWER

Cable

15" type GT1595 12.1" type GT1585

10.4" type GT1572

1

A1SP60

POWER

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

8.4" type GT1562

GOT

*1

PLC Extension base

2

8.4" type GT1565

*2

Max. 6m

Bus connection unit

15" type GT1595

Max. 30m

Bus connector conversion box

PLC Main base

Within 6m

GOT main unit

10.4" type GT1572

A1SP60

POWER

Cable

*5

1

Cable

PLC Extension base

1

8.4" type GT1562

POWER

Max. 6m

GOT

8.4" type GT1565

PLC Main base

POWER

A1S62P

mum n axi u M

GT15-A1SC B

1

For connectable CPU models, refer to "Connectable mode list" on page 28.

*5

*2

A1SP60

POWER

1

*1

PLC Extension base

PLC Extension base

Cable

2

units

Bus connection

Max. 6m

When A1SJ(H) or AnS(H) CPU is connected

1

Cable

A1S62P

Bus connector conversion box

POWER

Within 6m

A1S62P

3

units

A1SP60

POWER

A1S62P

0

36m

6m

PLC Extension base

More than 6m

When QnAS or A2US(H) is connected

d

GOT connection conditions

With extension base unit

d

AnSCPU type

er of GO mb

connecte Ts

When connected with QnASCPU type

connecte Ts

er of GO mb

GT15-75ABUS2L GT15-ABUS2

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

8.4" type GT1562

15" type GT1595 12.1" type GT1585 10.4" type GT1575 10.4" type GT1572 8.4" type GT1565 8.4" type GT1562

GT15-75ABUS2L GT15-ABUS2

GT15-C BS 07 : 0.7m 12 : 1.2m 30 : 3m 50 : 5m 100 : 10m 200 : 20m

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572 8.4" type GT1565 8.4" type GT1562

Max. 36m

44

*1: Includes the extension cable length (between base units). For "main base unit ⇔ extension base unit" cable details, refer to the MELSEC-QnA/A catalog (L-174-0-C5177-B NA-0109). *2: A bus connector conversion box is required if the first GOT is installed at a distance of 30m or more. *3: Select cables so that the total cable length is 36m or less from the PLC to the last GOT.

*4: GT15-C EXSS-1: • Comprises the GT15-EXCNB (0.5m) and the GT15-C BS (10 to 30m). • Calculate cable lengths as follows: GT15-C100EXSS-1 (10m), GT15-C200EXSS-1 (20m), GT15-C300EXSS-1 (30m).

*5: Cable length can be read from cable model name. For example, "GT15-A1SC NB" is 0.45m long. *6: Select cables so that the total cable length does not exceed 30m.

45


Bus connection 5

mum n axi u M

1

unit

GOT connection conditions Number of GOTs

System configuration

Installation distance of the first unit from main base

Cable

Connection distance 0m GOT

Cable Cable

Power supply unit

Cable

1

*1

*2

1

GOT

Cable

2

GOT

2

Cable

3

3

GOT

*2

1

1

0 Max. 1m

A0J2CM

A0J2-PW

03: 0.3m (for horizontal installation) 06: 0.55m (for vertical installation) 10: 1m (for extension) 20: 2m (for extension)

GT15-J2C10B 10 : 1m

GOT main unit

Bus connection unit

15" type GT1595

GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2

12.1" type GT1585 10.4" type GT1575 10.4" type GT1572

GOT main unit

Bus connection unit

GOT main unit

Bus connection unit

Bus connection

Within 1m

0

1m

Power supply unit *1

PLC

1 unit

For connectable CPU models, refer to "Connectable mode list" on page 28.

d

When connected with A0J2HCPU

connecte Ts

er of GO mb

8.4" type GT1565 8.4" type GT1562

Max. 6m *1: The power supply unit is required for connecting GOT. *2: Cable length can be read from cable model name. For example, "GT15-J2C10NB" is 1m long.

For details regarding connection to an A series motion controller, refer to the "GOT1000 series Connection Manual" (SH (NA)-080532ENG).

"Number of GOT extension stages" and "slot No." settings 1. Controller and recognition of GOT When GOT uses a bus, the CPU recognizes GOT as follows: • QCPU (Q mode) : Intelligent function unit with 16 I/O points. • Other than QCPU (Q mode): Intelligent function unit with 32 I/O points.

2. I/O assignment (1) For connection to the QCPU (Q mode) Install 1 extension stage (16 points x 10 slots) for a GOT connection. (GOT cannot be assigned to a vacant I/O slot at the main base or any extension base.) Note By setting I/O slots that are not used for GOT as vacant (0 point), "16 points x 1 vacant slot" I/O numbers can be used for other devices. (This setting is specified in the GX Developer's [PLC parameter setting] - [I/O assignment setting].) Reference See the "Precautions" section, item 9 (For Q mode connection).

(2) For other PLCs connection Assign the GOT to a vacant I/O slot at the extension base. If there is no extension base, or if the extension base has no vacant slots, install another extension stage, and assign GOT to an I/O slot there. (GOT cannot be assigned to a main base I/O slot.)R Reference See the "Precautions" section, item 10. For connection to QnA(S)CPU type and An(S)CPU type.

Precautions 1. At GOT power ON (1) System construction While PLC CPU is in reset status until the GOT is started, sequence program will not starts. It is not possible to construct a system in which the sequence program turns the GOT power ON.

(2) Time period from GOT power ON to PLC run status A PLC run starts approximately 10 seconds after the GOT starts up following a GOT power ON. When installing a new GOT in an existing system, or when replacing an existing GOT, the system timing should be adjusted to allow for this 10-second PLC startup delay.

(3) Power ON order when 3 or more GOTs are connected (for QCPU (Q mode) connection) Reference See item 9. (1) "Total cable length restriction when connecting multiple GOTs"

(4) Power ON order when connected to a Q4ARCPU redundant system Reference See item 13. (2) "Power ON order for GOT and Q4ARCPU redundant system"

(5) GOT and PLC power ON order in systems other than those described in items (3) and (4) above The system can be started regardless of whether the GOT power or the PLC power is turned ON first. There is no specified power ON order for GOT and the PLC. However, if a GOT→ PLC power ON order is used, operation occurs as follows. A system alarm (No.402: time-out error) occurs if the PLC is OFF when the GOT power is turned ON. GOT automatically begins monitoring after the PLC CPU is turned ON. Use the system information to reset the alarm.

2. At GOT restarts (OFF→ON) (1) GOT restart (OFF→ON) precaution Do not restart GOT (OFF→ON) while the PLC power is ON. Before restarting GOT (OFF→ON), always be sure to turn the PLC power OFF. Note GOT1000 series automatic reboot operation

46

Because GOT1000 series automatically reboot at the conditions of OS installation and Utility setting changes, there is no need for a GOT restart (OFF→ON). • When an OS installation occurs from GT Designer2 or from the CF card. • When the utility setting content is changed.

(2) When GOT power is turned OFF before the user created screens are displayed on GOT Communication may stop if the GOT power is turned OFF before the user created screens are displayed.If this occurs, restart the PLC CPU and GOT.

(3) Power ON order when 3 or more GOTs are connected (for QCPU (Q mode) connection) Reference See item 9. (1) "Total cable length restriction when connecting multiple GOTs"

3. The GOT's reset switch The reset switch on the GOT is disabled when using a bus connection.

4. At PLC power OFF or reset (1) When a PLC power OFF or reset occurs during monitoring A system alarm (No.402: time-out error) occurs if a PLC power OFF or reset occurs during monitoring. GOT automatically resumes monitoring when a PLC CPU recovery occurs. Use the system information to reset the alarm.

(2) When a PLC CPU power OFF or reset occurs before the user created screens are displayed on GOT Communication may stop if a PLC CPU power OFF or reset occurs before the user created screens are displayed on GOT. If this occurs, restart the PLC CPU and GOT.

(3) Power ON order when 3 or more GOTs are connected (for QCPU (Q mode) connection) Reference See item 9. (1) "Total cable length restriction when connecting multiple GOTs"

5. GOT connection position The GOT must always be connected to the last extension of a system. GOT cannot be connected between stages.

6. When GOT is connected to a PLC CPU via bus connection without having installed a communication driver A PLC CPU reset status occurs if GOT is connected to a PLC CPU via bus connection without having installed (at GOT) the basic function OS and a communication driver for the bus connection (communication with the PLC CPU using GX Developer, etc., is disabled). If the above occurs, disconnect GOT's bus connection cable to clear the PLC CPU's reset status.

7. System design When the GOT power is turned OFF, the current consumption values shown below are supplied to GOT from the PLC CPU side (power supply unit at main base unit). (GOT operation is disabled when the Total current consumption GOT power is OFF.) Be sure to Connection target CPU Number of GOTs 5 units 2200mA design the system so that the 4 units 1760mA "5VDC current consumption of When using Q CPU 3 units 1320mA the unit installed at the main (Q mode) 2 units 880mA base unit" and the "GOT current 1 unit 440mA consumption" total value does 3 units 360mA For other than QCPU 2 units 240mA not exceed the 5VDC rated (Q mode) connections 1 unit 120mA output of the power supply unit being used.

8. When assigning GOT input/output signals Do not use a sequence program, etc., in an attempt to use input/output signals (assigned to the PLC CPU) to the GOT system. If this is attempted, GOT operation cannot be guaranteed.

9. When using QCPU (Q mode)

11. When multiple GOTs are connected

(1) Total cable length restriction when connecting multiple GOTs

(1) Composite GOT system

The following restrictions apply when 3 or more GOTs are connected. Number of GOTs

Within 15m

○ ○ ○ ○ ○

1 unit 2 units 3 units 4 units 5 units

Total cable length Within 15 to 20m Within 20 to 25m

○ ○ ○ ○ #

○ ○ ○ # #

GOTs other than the GOT1000 Series cannot be used together with GOT1000 series.

(2) GOT quantity restriction Within 25 to 37m

○ ○ # # #

The number of GOTs that can be connected is limited according to the connection target CPU and number of special function units which are installed. Connection target CPU

does not apply. ○:: Restriction # The PLC and all GOTs must have the same power supply, and must all switch ON and OFF simultaneously.

(2) When using Q00JCPU The bus extension connector box can be installed only at an extension base unit. (It cannot be installed at the main base unit.)

QCPU (Q mode), motion controller CPU (Q series) QCPU (A mode) QnACPU

ACPU

(3) When using Q00J/Q00/Q01CPU When connected to Q00JCPU by a bus connection, the number of extension stages (including GOT) must not exceed 2. When connected to Q00CPU, Q01CPU by a bus connection, the number of extension stages (including GOT) must not exceed 4.

(4) When using the QA1S6MB type extension base unit Although GOTs can be connected to the last stages of all extension base units, the "number of GOT extension stages" setting must be assigned at the end of the QMMB extension base units. The "number of extension stages" for the QA1S6MB extension base unit is assigned at the last stage of the "number of GOT extension stages". Q38B main base unit

Q68B extension base unit

QA1S68B extension base unit GOT

Connection method Level of extension base unit

1

3

2

10. For connection to the QnA(S)CPU and An(S)CPU types GOT can be connected only at one of the main base unit's extension connectors. (Concurrent GOT connections at both the extension connectors is not permitted.)

(2) For Q4A(R)CPU, Q3ACPU, A3MCPU, and A4UCPU A vacant I/O slot is required within the "maximum number of extension stages" range.

(3) For A0J2HCPU Assign GOT to I/O slots 0 to 3 at the first extension stage.

(4) For CPUs other than items (2) and (3) above Even if the maximum number of extension stages are being used, and there are no vacant slots, a GOT can be connected by using the following communication interface settings, provided that there are 32 or more vacant I/O points. Connection target CPU

Communication interface setting Max. number of the extension base units No. of Extension Stages Slot No. 1 3 7 7 1

2 4

0 0 Use is prohibited

Max. 5 units

5 GOTs + 6 intelligent function units*2

Connection prohibited Max. 3 units Max. 3 units Max. 2 units Max. 1 unit Connection prohibited

Total 6 units Total 6 units Total 2 units Total 2 units

Max. 3 units Max. 2 units

1

1 Total 6 units Total 2 units

*1: This applies to the following intelligent function unit types: AD51 (S3), AD51H (S3), AD51FD (S3), AD57G (S3), AJ71C21 (S1), AJ71C22 (S1), AJ71C23, AJ71C24 (S3/S6/S8), AJ71UC24, AJ71E71 (-S3), AJ71E71N-B2/B5/T/B5T, AJ71E71N3-T, AJ61BT11 (only in intelligent mode), A1SJ71C24 (-R2/PRF/R4), A1SJ71UC24 (-R2/PRF/R4), A1SJ71E71-B2/B5 (-S3), A1SJ71E71N-B2/B5/T/B5T, A1SJ71E71N3-T, A1SD51S, A1SJ61BT11 (only in intelligent mode) *2: Only the A1SD51S intelligent function unit can be connected to the QCPU (Q mode).

12. When using the PLC CPU in a direct format Note that a vacant I/O slot's input "x" input cannot be used when a direct I/O control mode is used for the connection target PLC CPU, with a 5m extension cable (GT15-AC50B, GT15A1SC50NB), and with the first GOT connected to the main or extension base unit. This restriction does not apply when a "refresh" I/O control mode is used. At PLC CPU's equipped with an I/O control mode selector switch, set the switch to the "refresh" format. Note Examples of a vacant I/O slot's "x" input usage • When input "x" is assigned at the MELSECNET/10 network. • When a vacant I/O slot's input "x" is turned ON/OFF from the computer link unit. • When a vacant I/O slot's input "x" is turned ON/OFF by the GOT touch-switch function (bit SET/RST/alternate/momentary).

13. For connection to a Q4ARCPU redundant system

(1) For connection to the QnASCPU and AnSCPU types

A1MCPU/A2USCPU(-S1) A2MCPU/Q2ACPU A3MCPU/A4MCPU Q3ACPU/Q4ACPU A0J2HCPU

Motion controller CPU (A series)

AnUCPU,AnACPU,A2US(H)CPU AnNCPU,AnS(H)CPU,A1SJ(H)CPU A0J2HCPU A1FXCPU A273UCPU,A273UHCPU(-S3), A373UCPU(-S3),A173UHCPU(-S1) A171SHCPUN,A172SHCPUN

Number of GOTs that Total Permissible GOT + Intelligent can be connected Function Unit*1 Connections

(1) For a bus connection with a Q4ARCPU redundant system Connect the GOT to the redundant system extension base unit (A68RB) at the Q4ARCPU redundant system's last stage. A version "B" or later redundant system extension base unit must be used. The redundant system extension base unit's version is indicated in the "DATE" column at the rated plate. Note Q4ARCPU redundant system configuration precautions GOT will not operate properly in the following system configurations. • When GOT is bus-connected to the bus switching unit (A6RAF) of the redundant system main base unit (A32RB/A33RB). • When GOT is bus-connected to a version "A" redundant system extension base unit (A68RB).

(2) Power ON order for GOT and a Q4ARCPU redundant system The power ON order for GOT and a Q4ARCPU redundant system should be as follows. 1) GOT power ON. 2) After the monitor screen displays at GOT, the Q4ARCPU redundant system power switches ON. As a "time-out" system alarm then displays, use the system information to reset the alarm.

47


Specification General specifications

Power supply specifications

Item

Specification

Operating ambi- Display ent temperature Other than display

0 to 50°C*6 0 to 55°C*6

Storage ambient temperature

-20 to 60°C

Operating ambient

humidity*1

10 to 90% RH, no condensing

Storage ambient humidity*1

10 to 90% RH, no condensing Frequency Based on

Vibration resistance*2

If intermittent vibration occurs

JIS B 3502, IEC61131-2

If continuous vibration occurs

Acceleration Single amplitude Sweep count

5 to 9Hz

9 to 150Hz

9.8m/s2

5 to 9Hz

1.75mm

9 to 150Hz

4.9m/s2

3.5mm 10 times in each of X, Y, and Z directions

Based on JIS B 3502, IEC 61131-2 (147m/s2, 3 times in X, Y and Z directions)

Impact resistance Operating atmosphere

No corrosive gas

Altitude*3

2000m or less

Installation location

Inside the control panel

Overvoltage category*4

II or lower

Contamination*5

2 or less

Cooling method

Self cooling

*1: Wet bulb temperature for STN display type is 39°C or lower. *2: Refer to the Communication Unit User's Manual for vibration resistance specifications when using a MELSECNET/10 communication unit (GT15-75J71LP23-Z, GT15-75J71BR13-Z) or a CC-Link communication unit (GT15-75J61BT13-Z). Communication units specs. are different from GOT specs. *3: Do not operate or store the GOT unit in pressurized environments where the pressure exceeds the 0m elevation atmospheric pressure, as this could result in abnormal operation. *4: Assuming that the device is connected at some point between a public power distribution network and local system equipment. Category II applies to devices that are supplied with power from fixed equipment. The surge withstand voltage is 2500V for devices with ratings up to 300V. *5: Index that indicates the level of foreign conductive matter in the operating environment of device. Contamination level 2 denotes contamination by non-conductive matter only, though momentary conductivity may occur due to occasional condensation. *6: 0 to 40°C for GT115□HS. *7: Excluding GT115□HS.

Screen size

GT1575-STBA

Specification GT1575-VTBA GT1575-VNBA

GT1572-VNBA

GT1585-STBD

GT1575-STBD

GT1575-VTBD

GT1572-VNBD

XGA:1024 x 768 [dot]

304.1(W) x 228.1(H) [mm] 246(W) x 184.5(H)[ mm]

Contrast adjustment

For 16-dot standard font : 50 chars. x 37 lines (two bytes)

For 12-dot standard font

For 12-dot standard font

: 85 chars. x 64 lines (two bytes)

: 66 chars. x 50 lines (two bytes)

Life

350 [cd/m2]

Back light

Life *2

Key size

8-step adjustment

256 colors / 65536 colors *1 380 [cd/m2]

150 [cd/m2]

4-step adjustment

8-step adjustment

4-step adjustment

(operating ambient temperature: 25°C)

(operating ambient temperature: 25°C)

1900 keys per screen

(per key)

(per key) (16 x 8 at final line only)

(per key)

5.7"

256 colors

16-tone gray scales Right/left: 45°,

Right/left: 50°, Up: 50°, Down: 60°

Up: 20°, Down: 40°

Number of touch keys Touch panel

350 [cd/m2]

220 [cd/m2]

1,000,000 or more operations (pressing force of 0.98N or less) 1(m)

 

Detection delay time

0 to 4 [sec]

 5 MB built-in flash memory

9 MB built-in flash memory (for saving project data, extended function OS/optional function OS)

*4

Life (number of writings)

(for saving project data, extended function OS/optional function OS)

Battery

Built-in interface

220 [cd/m2]

(for saving project data,

(for saving project data,

extended function OS/

extended function OS/

optional function OS)

optional function OS)

USB interface

Min. 16 x 16 [dots] (per key) RS-232 interface

Max. 2 points 1,000,000 or more operations (pressing force of 0.98N or less)

* This illustration shows the GT1595-XTBA.

3 MB built-in flash memory (for saving project data)

GT11

100,000 writings

CF card cover

Approx. 5 years (operating ambient temperature: 25°C) Battery

57600, 38400, 19200, 9600, 4800 bps Connector shape: D-sub 9-pin (female)

RESET switch

Application: Communication with connected devices RS-422/232, 2ch (select 1ch when using) Transmission speed: 115200, 57600, 38400, RS-422/232

19200, 9600, 4800 bps Connector shape: Round 32-pin (male)

Built-in

RS-232 interface

Application: Communication with connected devices USB interface

Application: Communication with connected devices, connection to personal computer (for project data uploads/downloads, OS installation, FA transparent function)

Connector shape: D-sub 9-pin (male)

Connector shape: Mini-DIN6-pin (female)

Application: Communication with connected devices,

Application: Communication with connected devices,

interface

RS-232

USB (Full Speed 12Mbps), device, 1ch, Connector shape: Mini-B Application: Connection to personal computer (for project data uploads/downloads, OS installation, FA transparent function)

connection to personal computer (for project data uploads/ connection to personal computer (for project data uploads/

Compact Flash slot: 1ch, Connector shape: TYPE I, Application: For data transmission and data saving

downloads, OS installation, FA transparent function)

1ch for optional function board installation

Extension unit Buzzer output Environmentally protective construction

1ch for multi-color display board installation

USB

2ch for communication unit installation

CF card

Single tone (tone length is adjustable)

Optional function board

JEM1030 Front face: IP67f *5 Inside panel: IP2X 397(W) x 296(H) x 61(D) [mm] 316(W) x 242(H) x 52(D) [mm]

303(W) x 214(H) x 49(D) [mm]

241(W) x 190(H) x 52(D) [mm]

383.5(W) x 282.5(H) [mm] 302(W) x 228(H) [mm]

289(W) x 200(H) [mm]

227(W) x 176(H) [mm]

Weight

2.3 [kg]

1.9 [kg]

Supported

(excluding the mounting bracket)

(excluding the mounting bracket)

External dimensions (without USB port cover) Panel cut dimensions

4.9 [kg]

2.8 [kg]

2.4 [kg]

Supported Drawing software software package Simulator function *1: 65,536 colors when multi-color display board is installed. *2: Using the GOT screen save / backlight OFF functions prevents screen burn-in and extends the backlight life. *3: Analog resistance film type screen. When 2 points on the screen are touched simultaneously, if a switch is located in the middle of the 2 points then the switch will be activated. Therefore, avoid touching 2 points on the screen simultaneously. *4: The internal memory is a ROM that permits new data overwriting without having to delete the existing data.

USB (Full Speed 12Mbps), device, 1ch Connector shape: Mini-B Application: communication with personal computer (for project data uploads/downloads, OS installation, FA transparent function) Compact Flash slot: 1ch, Connector shape: TYPE I, Application: For data transmission and data saving 1ch for optional function board installation

Single tone (tone length is adjustable) Environmentally protective construction JEM1030 Front face: IP67f *3 Inside panel: IP2X JEM1030 IP65f *4

Panel cut dimensions

(excluding the mounting bracket) (excluding the mounting bracket) (excluding the mounting bracket)

downloads, OS installation, FA transparent function)

Buzzer output

External dimensions (without USB port cover)

GT Designer2 Version 2.18U or later GT Simulator2 Version 2.18U or later *5: Conforms to the IP67f (JEM1030) standard when the USB port cover is installed. (The USB interface conforms to IP2X (JEM1030) when a USB cable is connected.) However, this does not guarantee protection in all user environments. On LCD screens, bright dots (permanently lit) and black dots (not to be lit) generally appear. Because the large number of display elements exist on an LCD screen, it is not possible to reduce appearance of the bright and black dots to zero. Note that the existence of bright and black dots is a standard characteristic of LCD screens, and it does not mean that the products are defective or damaged.

CF card interface

RS-422 interface POWER LED

Optional function board interface (shipped with cover)

Power supply terminal

57600, 38400, 19200, 9600, 4800 bps

1ch for multi-color display board installation

CF card access switch

CF card access LED

Clock, alarm history, recipe data

RS-232, 1ch, Transmission speed: 115200,

Multi-color display

Touch panel

300 keys per screen (15 lines x 20 columns matrix resistive type)

57600, 38400, 19200, 9600, 4800 bps

CF card

Multi-color display board interface

Human sensor (GT1595, GT1585 only)

RS-232, 1ch, Transmission speed: 115200,

Optional function board

48

350 [cd/m2]

POWER LED

Backed up data

RS-422

9 MB built-in flash memory 5 MB built-in flash memory

CF card access switch

Power supply terminal

RS-232, 1ch, Transmission speed: 115200, 57600, 38400, 19200, 9600, 4800 bps Connector shape: D-sub 9-pin (male)

USB

Weight

Up: 20°, Down: 40°

RS-422, 1ch, Transmission speed: 115200,

Clock and maintenance schedule notification data Approx. 5 years (operating ambient temperature: 25°C)

Life RS-232

16-tone gray scales Right/left: 45°,

Cold cathode fluorescent tube (not replaceable) with backlight OFF detection function, and selectable backlight OFF / screen save time

Life (number of writings)

Life

100,000 writings

Backed up data

CF card interface Battery holder CF card access LED

Optional function board interface

Approx. 75,000 hours or more Approx. 54,000 hours or more Approx. 75,000 hours or more Approx. 54,000 hours or more (time for display intensity to become 50% at operating ambient temperature of 25°C)

No. of simultaneous touch points C drive

256 colors Right/left: 50°, Up: 50°, Down: 60°

8-step adjustment

GT15-BAT type lithium battery (optional) Battery

S.MODE (OS installation switch) (GT1595 only)

Extension unit interface

GT11-50BAT type lithium battery

Right, left, up, down: 70°

GT15 RESET switch

Approx. 50,000 hours (operating ambient temperature: 25°C)

Key size Life

Max. 2 points

Detection range

Component Names

16-step adjustment

Intensity

Memory*2

Detection distance

C drive

Display color

Backlight

1200 keys per screen Min. 16 x 16 [dots]

STN color display STN monochrome (black/white) display

115(W) x 86(H) [mm]

Life

(30 lines x 40 columns matrix resistive type)

Min. 16 x 16 [dots]

GT1155HS-QSBD GT1150HS-QLBD

QVGA: 320 x 240 [dot]

Life *1

Min. 16 x 16 [dots]

STN monochrome (black/white) display

Display size

Contrast adjustment

Approx. 40,000 hours or more

3072 keys per screen

STN color display

Contrast adjustment

(time for display intensity to become 50% at operating ambient temperature of 25°C) (48 lines x 64 columns ) (38 lines x 50 columns matrix resistive type)

GT1150-QLBD

Resolution

View angle

16 colors

200 [cd/m2] Approx. 41,000 hours

Approx. 50,000 hours or more

Specification GT1155-QSBD

Number of display characters For 16-dot standard font: 20 chars. x 15 lines (two bytes),For 12-dot standard font: 26 chars. x 20 lines (two bytes)

Right/left: 65°, Up: 50°, Down: 60° Right/left: 45°, Up: 20°, Down: 20°

Approx. 50,000 hours

Life

Memory

16 colors

Right/left: 45°, Up: 30°, Down: 20°

380 [cd/m2]

GT1150-QLBD GT1150HS-QLBD

0.5 to 0.8 [N·m]*1

0.5 to 0.8 [N·m]

Screen size 171(W) x 128(H) [mm]

256 colors

Simultaneous touch No. of simultaneous touch points prohibited*3 (1 point only)

Human sensor

Item Type

Cold cathode fluorescent tube (replaceable) with backlight OFF detection function, and selectable backlight OFF / screen save time

Number of touch keys Touch panel

TFT color display

brightness, wide viewing angle)

Display

280 [cd/m2]

GT1155-QSBD GT1155HS-QSBD

Performance specifications (GT11)

For 12-dot standard font: 53 chars. x 40 lines (two bytes)

256 colors / 65536 colors *1

Approx. 52,000 hours (operating ambient temperature: 25°C)

GT1562-VNBD

For 16-dot standard font: 40 chars. x 30 lines (two bytes)

Right/left: 75°, Up: 50°, Down: 60° Right/left: 60°, Up: 40°, Down: 50° Right/left: 50°, Up: 35°, Down: 45° Right, left, up,down: 85°

Intensity

GT1565-VTBD TFT color display (High-

VGA:640 x 480 [dot]

: 64 chars. x 48 lines (two bytes)

450 [cd/m2]

GT1562-VNBA

211(W) x 158(H) [mm]

For 16-dot standard font

GT1585-STBD

Input power supply voltage 100 to 240VAC (+10%, -15%) 24VDC (+25%, -20%) 24VDC (+10%, -15%) 50/60Hz ±5%  Input frequency   Input maximum voltampere 110VA (at max. load) 90VA (at max. load)  28W or less Power consumption 51W or less 26W or less 31W or less (1290mA/24VDC) 26W or less (1080mA/24VDC) 9.84W or less (410mA/24VDC) 9.36W or less (390mA/24VDC) 20W or less 20W or less (830mA/24VDC) With backlight off 28W or less 20W or less 4.32W or less (180mA/24VDC) 115A or less (1ms, at max. load) Rush current 50A or less (4ms, at max. load) 45A or less (4ms, at max. load) 40A or less (4ms, at max. load) 15A or less (2ms, at max. load) Within 20ms (100VAC or more) Within 10ms Permissible instantaneous failure time Within 5ms Noise width 1 µs, and noise frequency 25 to 60 Hz, Noise width 1 µs, and noise frequency 25 to 60 Hz, Noise width 1 µs, and noise frequency 30 to 100 Hz, Noise resistance by noise simulation with noise voltage 1,500 Vp-p by noise simulation with noise voltage 500 Vp-p by noise simulation with noise voltage 1,000 Vp-p 1500VAC between power supply terminal and ground for 1 minute 500VAC between power supply terminal and ground for 1 minute 500VAC between power supply terminal and ground for 1 minute Dielectric withstand voltage 10MΩ or higher with an insulation resistance tester 10MΩ or higher with an insulation resistance tester (500VDC between power supply terminal and ground) Insulation resistance (500VDC between power supply terminal and ground) 0.75 to 2 [mm2]*1 0.75 to 2 [mm2] Applicable wire size Crimp terminal for M3 screw RAV1.25-3, V2-N3A, FV2-N3A*1 Crimp terminal for M3 screw RAV1.25-3, V2-S3.3, V2-N3A, FV2-N3A Crimp terminal

8.4"

SVGA: 800 x 600 [dot]

Display color

GT1565-VTBA

10.4"

Display size

View angle

TFT color display

12. 1"

Resolution

Number of display Display characters

GT1575-VNBD

(High-brightness, wide viewing angle) 15"

GT1585-STBA

*1: Excluding GT115□HS.

GT1585-STBA

TFT color display

Type

GT1595-XTBA

GT1575-STBD GT1575-VTBD GT1575-VNBD GT1572-VNBD GT1565-VTBD GT1562-VNBD

Specification

GT1595-XTBA

Item

Tightening torque (terminal block's terminal screws)

Performance specifications(GT15) Item

Specification GT1575-STBA GT1575-VTBA GT1575-VNBA GT1572-VNBA GT1565-VTBA GT1562-VNBA

164(W) x 135(H) x 56(D) [mm]

176(W) x 220(H) x 93(D) [mm]

153(W) x 121(H) [mm]

0.7 [kg] (excluding the mounting bracket)

1.0 [kg] (Main unit only)

Drawing software

GT Designer2 Version 2.18U or later

software package Simulator function

GT Simulator2 Version 2.18U or late

*1: Using the GOT screen save / backlight OFF functions prevents screen burn-in and extends the backlight life. *2: The internal memory is a ROM that permits new data overwriting without having to delete the existing data. *3: Conforms to the IP67f (JEM1030) standard when the USB port cover is installed. (The USB interface conforms to IP2X (JEM1030) when a USB cable is connected.) However, this does not guarantee protection in all user environments. *4: Does not apply when IP65f-rated interface covers on top and rear face are removed. On LCD screens, bright dots (permanently lit) and black dots (not to be lit) generally appear. Because the large number of display elements exist on an LCD screen, it is not possible to reduce appearance of the bright and black dots to zero. Note that the existence of bright and black dots is a standard characteristic of LCD screens, and it does not mean that the products are defective or damaged.

Touch panel

Handy GOT CF card interface Environmentally protective cover

RS-232 interface Emergency stop switch

USB interface

Hook for wall mounting

Key type selector switch

Hook for neck strap Rear face protective cover

Touch panel

Optional function board interface Battery

POWER LED Operation switches (6 switches)

Hand strap

RS-422/232 interface Grip switch

49


External dimensions (Unit: mm)

10

42

5

50

110

4

13

58

49.9

Fig.

33

12.4 49.9

49.9

1000 Cable approx. Ø8.0 70

100

10

Ferrite core, approx. Ø35 x 40, green holder tube

Ferrite core, approx. Ø35 x 40, GOT side green holder tube

A7GT-CNB side

50

3000

53

A0J2-PW side

16

Fig.

16

50

3000

14

50

L

53

12

16

13

35

55 16

Fig.

Fig.

16

50

3000

15 55

35

Ø7

50

16

Ø6 35

Fig. 11 Fig. 12 Fig. 13

13

Ø20 x 28

35

External dimensions

40

Ø7

35

Cable length (L) 3m 10, 20, 30 m 1, 3, 10, 20, 30 m

5

Fig.

External dimensions

16

13

Fig. 14 Fig. 15 Fig. 16

50

L

40

16

Fig.

13

50

3000

53

16

16

Ø15 x 28.5

Ø6

Ø6 55

Cable length 3m 3m 3m

13

Cable model name

35

74

35

47 56

53

52

20

11

80 or more

* The GOT ambient temperature must always be 55°C or less.

With CF Card

50 or more

100 or more

E 100 or more

7

Model name GT15-QBUS GT15-QBUS2 GT15-ABUS GT15-ABUS2

A 2.3 2.5 4.5 4.5

B 0.5 3.0 0.8 3.0

C 12 11 15 11

D

31.5  29 33.5 29.5  31 31

*3: Dimension X when mounting GOT

8.4" type 10.4" type, 12.1" type, 15" type

E

Model name GT15-75QBUSL GT15-75QBUS2L GT15-75ABUSL GT15-75ABUS2L

8.4" type 10.4" type, 12.1" type, 15" type

Fig.

2.3 2.3 3.9 3.9

29

17.6 98 117

98 112

12 11.5

30.5 21.5

7

64.2

46.7 44.5

28 102 When When the connector the connector is installed is installed

GOT main unit

To bus connection unit

63

Fig.

3

30

When F type connector is installed

GOT main unit GT15-75IF900

X

GT15-75IF900

150

150

Fig.

34

27

20

34

155

102

150

Fig.

Mounting hole 48

GOT main unit

15.5 13.5

9

30.5

21.5

57

4.25 39.5 4.25

A

*3 89.7

RS-422

57

26

20

RS-232

RS-422

(Unit: mm) *4: Dimension A of each communication unit.

*5: Dimension X when mounting GOT

23 21

C

30.5

21.5

101.8 A

25

Fig.

A

A

A C

30.5

21.5

Fig.

24 RS-232

X

29.5

Fig.

X

*1: Connector shapes vary according to the model name. *2: Dimensions A to E of each communication unit.

101.8

107 98

98 107

31.5

From base unit

A

*1 *3

*5

*5

GOT main unit 0.5

98 112

Plate thickness: 2 to 4mm

Fig. 25 Fig. 26 Fig. 27 Fig. 28 Fig. 29 Fig. 30

0.5

22

2.5

GT15-75IF900

*5

X

0.4

Without CF Card

Other device or control panel

D

A9GT-QCNB A7GT-CNB GT15-75J71LP23-Z GT15-75J71BR13-Z GT15-75J61BT13-Z GT15-J71E71-100

Fig.

*1 *4

3 GOT main unit

63

2.5 X

7

B

C

Fig. 24

0.5

23

GT15-75IF900

(Unit: mm)

C

E

*1 *4

80

50 or more (48 or more)

3

Fig.

Fig. 23

GT15-RS2T4-25P

Bottom

8

B

GT15-RS2T4-9P

Side

20.5

50 or more (36 or more) 50 or more (36 or more) 73 or more

63

2.5

Fig. 22

136.8 Front

19

GOT main unit

21

Side

Bottom

GT15-RS4-TE

Fig.

*1 *2 *3

D

48 38

GT1565

E

Fig.

136.8 Front

20

B

X

102

GT1575

Fig. 21

Fig.

39

GT1585

GT15-RS4-9S

D

71.5

GT1595

Fig. 21

*1 *2 *3

30.5 21.5

(Unit: mm)

GT15-RS2-9P

2.5

X

X

121

2.5

44.5

*1: Same dimensions as the A985GOT (-V). *2: Same dimensions as the A975/970GOT (-B). *3: Same dimensions as the F940GOT.

+2 0

Fig. 17 Fig. 18 Fig. 17 Fig. 18 Fig. 19 Fig. 20 Fig. 19 Fig. 20

17.6

153

B

Panel opening

Model name GT15-QBUS GT15-QBUS2 GT15-ABUS GT15-ABUS2 GT15-75QBUSL GT15-75QBUS2L GT15-75ABUSL GT15-75ABUS2L

18

20.5

Q-BUS (1ch) unit, standard model Q-BUS (2ch) unit, standard model A-BUS (1ch) unit, standard model A-BUS (2ch) unit, standard model Bus connection Q-BUS (1ch) unit, slim model unit Q-BUS (2ch) unit, slim model A-BUS (1ch) unit, slim model A-BUS (2ch) unit, slim model RS-232 serial communication unit (D-sub 9-pin (male)) Serial RS-422/485 serial communication communication unit (D-sub, 9-pin (female)) unit RS-422/485 serial communication unit (Terminal block) RS-232 → RS-422 conversion RS-422 unit (9-pin) conversion RS-232 → RS-422 conversion unit unit (25-pin) Bus extension connector box Bus connector conversion box MELSECNET/10 Optical loop communication unit Coaxial bus CC-Link communication unit Intelligent device station Ethernet communication unit

GOT main unit 3

133

GT15-75IF900

Product name

Fig.

GT15-75IF900

B 282.5 228 200 176

17 External dimensions

4.25

+2 0

3 GOT main unit B

63

Fig.

48 38

A

Communication unit

A

v5.7" type

50

60 50

Cable approx. Ø8.0

Ferrite core, approx. Ø35 x 40, blue holder tube

RS-232 cable 3.5

GT01-C30R2-6P GT01-C30R2-9S GT01-C30R2-25P

*1: Only applies to the GT15-75QBUSL, GT15-75QBUS2L, GT15-75ABUSL, and GT15-75ABUS2L. *2: Only applies to the GT15-QBUS, GT15-QBUS2, and GT15-ABUS2. · Dimensions shown in parentheses apply when there are no devices nearby (contactor, etc.) which produce radiated noise or heat. Even with these dimensions, however, the ambient temperature must never exceed 55°C. Depending on the unit and cable being used, a cable length longer than the dimension A shown above may be required.

50 or more

16

Fig.

383.5 302 289 227

When only GOT or 50 or more 50 or more a bus connection unit*1 is installed (20 or more) (31 or more) When a bus connection unit*2, or a serial 50 or more 50 or more communication unit is connected (20 or more) (31 or more) When an RS-422 converter is installed 50 or more 51 or more 68 or more When an Ethernet communication unit, 50 or more a MELSECNET/10 communication unit (coaxial), (20 or more) or a CC-Link communication unit is installed When a MELSECNET/10 50 or more 50 or more 50 or more communication unit (optical) is installed (20 or more) (26 or more) (43 or more) 80 or more (20 or more) 50 or more (20 or more) 100 or more (20 or more)

5.7" type

110

Motion controller side

10

204

209

GT01-C30R4-25P GT01-CMR4-25P GT01-CMR4-8P

5 6

56

GT1595 GT1585 *1 GT1575 *2 GT1565 GT1155 *3 GT1150 *3

A,D

Cable approx. Ø9.0

(Unit: mm)

v15" type /12.1" type / 10.4" type / 8.4" type

Size

L

33

110

160

62 16

Cable model name

When a GOT is installed, the spaces must be provided between other equipment as shown below.

B C,D E

FG cable

9

Ø7

mProduct installation interval

A

GT15-CMBS (Fig. 9)

RS-422 cable

120

135

190

75 72 62

152

GOT main unit type

Item

~

12.4

5

GOT side

(Unit: mm) 18

176 50

(Unit: mm)

Size

50

Cable approx. Ø8.0

Ferrite core, approx. Ø35 x 40, green holder tube

Fig.

GT15-EXCNB (Fig. 8)

mPanel cut dimensions 15" type 12.1" type 10.4" type 8.4" type 5.7" type 5.7" type

Fig.

L

33

12.4

10

10 175 10

Fig. A

168 226

49.9

Fig.

20.5

75

500 Cable approx. Ø9.0

PLC side

L

33

A7GT-CNB side

FG cable

1000

8

Ferrite core, approx. Ø32 x 16, green holder tube 12.4

20

External dimensions

120

175.5

Cable approx. Ø17.0

3

Ferrite core, approx. Ø35 x 40, green holder tube

33

Fig.

49

6

56 52

Handy GOT 164 120

12.4 70

60 50

Cable approx. Ø8.0

60

Fig.

5 56

6

288 CON2

241 175.5

PLC side

L

60

GOT side GOT side

GT1155 GT1150

110

7

49.9

214

10 199

242

10

6

61

PLC side CON1

GT1565

Fig.

50

Ferrite core, approx. Ø35 x 40, GOT side green holder tube

20

*1: The GT15-CMEXSS-1 is a set product consisting of the GT15-EXCNB and GT15-CMBS. (See Fig. A)

301

382

33

Cable approx. Ø8.0

PLC side

5

10

222

250

70

L

33

CON2

320

L

60

20

2

12.4

12.4

CON1

227

296

252

Ferrite core, approx. Ø35 x 40, green holder tube

Ferrite core, approx. Ø35 x 40, red holder tube

Fig.

110

Cable approx. Ø8.0

GOT side

281

10

263

Fig. 1 Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 + Fig. 9 Fig. 8 Fig. 9 Fig. 10

160

6

49.9

303

External dimensions

0.6, 1.2, 3, 5, 10 m 15, 20, 25, 30, 35 m 1.2, 3, 5 m 0.6, 1.2, 3, 5 m 1.2, 2.5 m 1.2, 2.5 m 0.7, 1.2, 3, 5 m 0.45, 0.7, 3, 5 m 10.6, 20.6, 30.6 m 0.5 m 0.7, 1.2, 3, 5, 10, 20, 30 m 1m

4.25

10

GT1575 316

Cable length (L)

GT15-QCMB GT15-QCMBS GT15-CMNB GT15-ACMB GT15-A370CMB-S1 GT15-A370CMB GT15-A1SCMB GT15-A1SCMNB GT15-CMEXSS-1*1 GT15-EXCNB GT15-CMBS GT15-J2C10B

Cable approx. Ø10

L

33

Fig.

95

58

GT1585

397 320

1

Cable model name

12.4

L 145

49.9

GT1595

(Unit: mm)

34.2

58

mExternal dimensions

10

Fig.

49.9

Bus connection cable

58

GOT main unit

21

*3

51


VGA

VGA

VGA

QVGA

QVGA

QVGA

QVGA

10.4"

8.4"

8.4"

5.7"

5.7"

5.7"

5.7"

Bus connection

v

v

v

v

v

v

v

v

CPU direct connection

v

v

v

v

v

v

v

v

v

v

v

v

Computer link connection

v

v

v

v

v

v

v

v

v

v

v

v

MELSECNET/10 connection

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Temperature controller connection

v

v

v

v

v

v

v

v

v

v

v

v

Inverter connection

v

v

v

v

v

v

v

v

v

v

v

Servo amplifier connection

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

MELSECNET/10 connection

v

v

v

v

v

v

v

v

CC-Link (ID) connection

v

v

v

v

v

v

v

Ethernet connection

v

v

v

v

v

v

9MB

9MB

9MB

9MB

5MB

P.11,48 Max.

Max.

Max.

Max.

57MB

57MB

57MB

v

v

v

v

16 gray scales 1024 x 768 dot 800 x 600 dot

P.28

Ethernet connection For connectable PLCs, refer to

other brand PLCs

the "Connectable model list" on page 30

Microcomputer connection

Communication protocol (15 type) compatible

P.8, 28

P.28

Optional expansion memory function board. Required using option (standard + option) Requires (GT15-QFNBMM) + CF card. Total memory capacity when

Multi-color display board is required.

256 colors

P.19,48

16 colors

640 x 480 dot

P.48

320 x 240 dot Number of touch keys (line x row)

P.21,48

USB (USB (Full Speed 12Mbps For PC communication (project data downloads/ device 1ch (Mini-B)) CF card interface (Compact Flash slot 1ch (TYPE 1))

uploads, OS installation, FA transparent function) For data transmission and data saving

Optional function

For optional function board installation

board interface (1ch)

(only for GT15 with expansion memory)

Extension unit interface (2ch)

For communication unit installation

P.48

Vertical display

Other

Clock function Buzzer output

GT15 requires a battery (GT15-BAT) to save clock data. Monotone (tone length is adjustable)

Human sensor Backlight OFF

GT15 backlight is replaceable.

detection function

GT1155-QSBD features a long-life backlight.

P.48

Environmentally protective construction Main unit functions

Boot OS installation OS installation*4 Project data downloads /uploads *5

Via USB or RS-232, using CF card Via Ethernet (GT15 only)*7,

P.20

Via USB or RS-232, using CF card

Specifications

Screen design

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Password

v

v

v

v

v

v

v

v

v

v

v

v

System information

v

v

v

v

v

v

v

v

v

v

v

v

Multilingual support function

Multilingual support device switches

P.12

the language of objects with comment groups.

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Parts registration

v

v

v

v

v

v

v

v

v

v

v

v

v

Data operation function

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Offset function

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Security function

v

v

v

v

v

v

v

v

v

v

v

v

Lamp display

v

v

v

v

v

v

v

v

v

v

v

v

v

Touch switch

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Numerical display/input

v

v

v

v

v

v

v

v

v

v

v

v

5MB

9MB

5MB

3MB

3MB

3MB

3MB

Data list display

v

v

v

v

v

v

v

v

v

v

v

v

Max.

Max.

Max.

Max.

v

v

v

v

v

v

v

v

v

v

v

v

57MB

53MB

53MB

57MB

53MB

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

3072

1900

Comment registration

ASCII display/input

v

P.12

255 comment groups per project

ASCII inputs limited to 16 chars.

Lower/higher bit display order is selectable.

Clock display

v

v

v

v

v

v

v

v

v

v

v

v

v

Comment display

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

1900

1200

1200

1200

1200

1200

300

300

300

300

v

v

v

v

v

v

v

v

v

v

Kana-kanji conversion function

Required Required

Advanced alarm

Advanced user alarm / advanced system

observation/display

alarm / advanced alarm popup window

Alarm list display

User alarm display / system alarm display

P.13

P.22

v

v

v

v

v

v

v

v

v

v

v

v

Alarm history display

v

v

v

v

v

v

v

v

v

v

v

v

Parts display

v

v

v

v

v

v

v

v

v

v

v

v

Parts movement

v

v

v

v

v

v

v

v

v

v

v

v

Panel meter display

v

v

v

v

v

v

v

v

v

v

v

v

Level display

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Trend graph

*3

*3

*3

*3

*3

*3

*3

*3

v

v

Historical trend graph*9

v

v

Line graph

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Bar graph

v

v

v

v

v

v

v

v

v

v

v

v

Statistical graph

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Scatter graph

v

v

v

v

v

v

v

v

v

v

v

v

Status observation function

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Time action function

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Hard copy function

File saved in CF card (BMP, JPEG)

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

CF card is required

v

v

(File saved in CF card)

v v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Screen call function

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Logging function

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

System monitor function

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

List editor for A

Required Required

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

List editor for FX

Required Required

v

v

v

v

v

v

v

v

v

v

v

v

Re- Required quired

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v *6

v *10

v *10

P.9,55

v

v

v

v

v

v

v

v

P.10

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Pop-up window

v

v

v

v

v

v

v

v

v

v

BMP image data

v

v

v

v

v

v

v

v

v

JPEG image data

v

v

v

v

v

v

v

v

DXF data

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

High-quality font

v

v

v

v

v

v

TrueType font

v

v

v

v

v

Windows ® font

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

Re- *9 Re- *9 quired quired

Advanced recipe

Required Required

Recipe function

Required Required

Bar-code function

P.15

P.14

Required

Required Required

P.15

Project script Script function

Object script

Ladder monitor function

P.13

Screen script Required Required Required

Use the GT15-QFNB (MM) for the Q/QnA ladder monitor function.

P.24

Intelligent unit monitor function

Required Required

Q motion monitor function

Required Required

Servo amplifier monitor function

Required Required

v

v

v

v

v

v

v

v

Network monitor function

Required Required

v

v

v

v

v

v

v

v

v

CNC monitor function

Required Required

v

v

v

v

v

Maintenance notification function Battery (GT15-BAT) is required

Required

v

v

v

v

v

v

v

v

v

v

v

For items shipped with the unit,

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

P.19

P.11

v

Station No. switching

v

v *6

Part (object + figure) Layer function

v

v

v

Re- Required quired

v

v

v *6

/ Gothic font

v

v

v

Traditional Chinese [Big5]

v

v

v *6

Re- Required quired

v

v

v

/ Mincho (GB2312)

v

v

v

Simplified Chinese [GB]

v

v

v

P.11

v

v

v

Standard font

v

v

v

format

v

v

v

Supported image data

v

v

v

Overlap window display

5.7"

Screen switching

Displays the desired image (BMP) at GOT startup. 1 basic comment per project*8

v

Superimposed window display Composite display windows on the base screen

QVGA

5.7"

Boot logo

v

Basic GOT display screen

QVGA

5.7"

v

v

Base screen

QVGA

5.7"

v

v

Required Required

QVGA

8.4"

v

v

Gateway function

VGA

8.4"

v

v

Required

VGA

10.4"

v

v

Multi-channel function

VGA

10.4"

v

v

Via USB or RS-232

VGA

10.4"

v

v

FA transparent function

VGA

10.4"

v

P.20

Resource data uploads *6

SVGA

12.1"

v

Other

Internal interface

RS-422/232 interface

SVGA

15"

v

v

RS-422 interface

XGA

v

(48 x 60) (38 x 50) (38 x 50) (30 x 40) (30 x 40) (30 x 40) (30 x 40) (30 x 40) (15 x 20) (15 x 20) (15 x 20) (15 x 20)

RS-232 interface

-XTBA -STBM -STBM -VTBM -VNBM -VNBM -VTBM -VNBM -QSBD -QLBD HS-QSBD HS-QLBD

Channel No. driver setting is required

Maintenance functions

Touch Resolution keys

Display colors

65536 colors

GT11

Page GT1595 GT1585 GT1575 GT1575 GT1575GT1572 GT1565 GT1562 GT1155 GT1150 GT1155 GT1150

Connected device setting

P.25

P.24

v

v

v

v

v

v

v

v

v

v

v

v

GT Designer2 Version2

GOT1000 compatible drawing software

P.16

v

v

v

v

v

v

v

v

v

v

v

v

GT Simulator2 Version2

GOT1000 compatible simulation software

P.18

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

v

GT Works2 Version2 Software

User memory capacity

Standard memory capacity

Via G4 only Via G4 only Via G4 only Via G4 only

Description

Optional *2 Function Board Extended/Optional *2 Function OS Installation

VGA

10.4"

Connection to

Category

VGA

10.4"

Common settings

SVGA

10.4"

Function *1

Model GT15

see the "Device List" (page 56).

List of products

SVGA

12.1"

CC-Link connection (ID/via G4)

Connection configuration

-XTBA -STBM -STBM -VTBM -VNBM -VNBM -VTBM -VNBM -QSBD -QLBD HS-QSBD HS-QLBD

15"

CNC connection

Hardware specifications

Page GT1595 GT1585 GT1575 GT1575 GT1575 GT1572 GT1565 GT1562 GT1155 GT1150 GT1155 GT1150 XGA

CPU direct connection

52

GT11

Object setting

Description

Model GT15

Screen design

Function *1

Optional *2 Function Board Extended/Optional *2 Function OS Installation

Category

Function list for each model

Easy data convert function GT Converter2 Version2

Converts GOT800 series, GP-PRO/ PBIIIC-Package03 to GT15, A900 data

*1: Function contents, such as the number of points to set and the destination to save files, vary according to the model. *2: For details, see the "Notes for use" section on page 54. *3: The RS-232 interface is used as an RS-422 interface by installing an RS-422 converter. *4: "OS" refers to the basic functions, communication drivers, extended functions, and optional functions. *5: "Project data" refers to user screen data (base screen, window screen), components, advanced recipes, comments, common settings, high-quality font, and the boot logo. *6: "Resource data" refers to the alarm log files (advanced alarms, alarm history), recipe files, advanced recipe files, data log files, screen transition information files, and hard copy files. The GT11 supports only the alarm log file (alarm history). *7: The GOT with basic functions installed must be equipped with an Ethernet communication unit. *8: Only 16-dot fonts (standard / high-quality Mincho font) are available. *9: Settings of the logging function are required in order to use historical trend graph function. In addition, the optional function board and optional function OS (Logging) must be installed. *10: Structural restrictions apply.

53


Notes for use

When using multi-channel function

CF card & optional function board selection When using the GT15 mWhen using optional functions & extended functions In order to use the optional functions shown in "Table A", an optional function board or an optional expansion memory function board must be installed, regardless of the project data capacity and the available user data space. Depending on the functions used, the OS installation may reduce the available user data space. Refer to "Table A" for the amount of user data space corresponding to the optional function OS and the extended function OS. If there is insufficient user space available, an optional expansion memory function board should be selected.

Functions Multi-channel*2 Maintenance notification function

Optional functions*1

mSelect according to project data capacity

*1:Standard memory capacity vary according to the the model. For details refer to the specification on page 48. *2: This is a general guideline.

When using the GT11 mWhen using optional functions & extended functions Install an optional function board in order to use the "Table A" optional functions.

Extended functions

Available user data space (KB) GT15

GT11

*3

None

*3

None

Simplified Chinese [GB] Mincho font

1280

None

Traditional Chinese [Big5] Gothic font

1920

None

Recipe

100

*4

Advanced recipe

1241

None

Logging

740

None

Kana-Kanji conversion function

1223

None

Object script

360

None

Gateway (server, client)

100

None

Gateway (mail)

100

None

Gateway (FTP)

64

None

List editor for MELSEC-A

1058

*4

List editor for MELSEC-FX

1058

*4

Ladder monitor for MELSEC-Q/QnA*2

1082

None

Ladder monitor for MELSEC-A

523

None

Ladder monitor for MELSEC-FX

592

None

Intelligent unit monitor

384

None

Q motion monitor

607

None

Servo amplifier monitor

524

None

Network monitor function

324

None

CNC monitor function

588

None

System monitor

746

*4

Bar-code

84

*4

*1: GT15···Use the optional function board (GT15-QFNB/GT15-FNB) or the optional expansion memory function board (GT15-QFNBMM). GT11···Use the optional function board (GT11-50FNB). *2: The GT15-FNB does not support the multi-channel function and the MELSEC-Q/QnA ladder monitor function. These functions require the GT15-QFNB (MM). *3: Installation of the optional function OS is not required. *4: Requires installation of the optional function OS and extended function OS, but the user data area cannot be used. The CF card can be used for the following GT15 functions: · Data transmission (also possible at GT11) · Advanced recipe · Historical trend graph · Advanced alarm · Recipe · Parts display · Alarm history (also possible at GT11) · Logging

· Parts movement · Hardcopy

Project data created in GT Designer can be used in GT Designer2.

mGOT900 series È GOT1000 series compatibility* • Using data from the GOT-A900 series GOT900 series project data can be used at the GOT1000 series. • Using data from the GOT-F900 series Data created in GT Designer and GT Designer2 can be used. Data must first be converted to GOT-A900 series data, and then to GOT1000 series data. *: Some data and function items cannot be used (not compatible).

For cable mBus connection cables • The GOT900 series bus connection cable cannot be used by the GOT1000 series. • The GOT1000 series bus connection cable cannot be used by the GOT900 series.

mRS-422 and RS-232 cables • The GOT900 series RS-422 and RS-232 cables cannot be used by the GOT1000 series. • The GOT1000 series RS-422 and RS-232 cables cannot be used by the GOT900 series.

Panel cut dimensions mGOT900 series È GOT1000 series compatibility • The A985GOT(-V) and the GT1585, the A975/970GOT(-B) and the GT1575, the F940GOT and the GT1155/1150, have the same panel cut dimensions. Therefore, it is not necessary to change the mounting holes when replacing an A985GOT(-V), A975/970GOT(-B), or F940GOT with a GOT1000 series unit.

54

Bus connection: 1ch (When using GT15-QBUS (2) or GT15-ABUS (2)) Serial connection*1: 1 to 3ch

Total: Up to 4ch

Bus connection: 1ch *2 (When using GT15-75QBUS (2) or GT15-75ABUS (2) L) Serial connection*1: 1ch Total: Up to 2ch *2 MELSECNET/10 connection (PC-to-PC Network): 1ch Serial connection*1: 1ch

Total: Up to 2ch

*2 CC-Link (ID) connection: 1ch Serial connection*1: 1ch

Total: Up to 2ch

Ethernet connection: 1ch Serial connection*1: 1 to 3ch

Total: Up to 4ch

Serial connection only*1: 1 to 4ch

*1: The serial connection includes the following connection configurations: · CPU direct connection · CC-Link connection (via G4) · Other brand PLC connection · Inverter connection · CNC connection (CPU direct connection) · Computer link connection · Microcomputer connection · Temperature controller connection · Servo amplifier connection *2: Because the following communication units cannot be connected together with other communication units (serial communication units, Ethernet communication units, etc.), GOT's built-in RS-232 interface must be used for serial connections. Therefore, the barcode function, the FA transparent function (via RS-232), the Ethernet download function, and the gateway function cannot be used. · Bus connection unit (slim type): GT15-75QBUS(2)L, GT15-75ABUS(2)L · MELSECNET/10 communication unit: GT-15-75J71LP23, GT-15-75J71BR13-Z · CC-Link communication unit: GT15-75J61BT13-Z

Total: Up to 4ch

mCommunication driver

mOptional function board

A communication driver must be installed for each of the connection configurations. Communication drivers for the 2nd and subsequent channels will be installed in the user area.

Use of the GT15-QFNB (MM) optional function board is required. The GT15-FNB cannot be used.

GT Designer2 (English version) operating environment Item

Description

Personal computer

PC/AT compatible machine running Windows® Microsoft® Windows® 98 Operating System (English, Chinese, Korean, German Versions) Microsoft® Windows® Millennium Edition Operating System (English, Chinese, Korean, German Versions) OS Microsoft® WindowsNT® Workstation 4.0 Operating System (English, Chinese, Korean, German Versions)*2 Microsoft® Windows® 2000 Professional Operating System (English, Chinese, Korean, German Versions)*2 CPU Pentium 200MHz or higher Required memory 64MB or more Free hard For installation 300MB or more disk space For operation 100MB or more Disk drive CD-ROM disk drive Display colors High color (16 bit) or more Display Resolution 800 x 600 dot or more • Internet Explorer Ver. 5.0 or later must be installed. Others • Mouse, keyboard, printer, CD-ROM drive which are compatible with the above OS.

Microsoft® Windows® XP Professional Operating System (English, Chinese, Korean, German Versions)*1*2 Microsoft® Windows® XP Home Edition Operating System (English, Chinese, Korean, German Versions)*1*2 Pentium II 300MHz or higher 128MB or more

*1: The following functions are not supported: Compatible Mode, Fast User Switching, Desktop Theme (Font) Change, Remote Desktop. *2: Administrator authority is required to install GT Designer2 on the following systems: Windows NT® Workstation 4.0, Windows® 2000 Professional, Windows® XP Professional, Windows® XP Home Edition; Administrator authority is required to operate GT Designer2 on Windows® XP Professional and Windows® XP Home Edition.

Forward compatibility For project data mGT Designer È GT Designer2 compatibility*

The following connection combinations are compatible with the multi-channel function.

Notes for use

A CF card and an optional function board with expansion memory are required if the project data size exceeds the standard memory capacity*1. Project data should be downloaded to Drive "A" (CF card). • Selecting a CF card Select a CF card that exceeds the project data capacity*2. • Selecting an optional expansion memory function board Select an optional function board with expansion memory that has the larger capacity than it is indicated as follows*2: [project data size] - [standard memory capacity*1].

mAcceptable combinations

[ Table A]

GT Simulator2 (English version) operating environment Item

Description

Personal computer

PC/AT compatible machine running Windows® Microsoft® Windows® 98 Operating System (English, Chinese, Korean, German Versions) Microsoft® Windows® XP Professional Operating System (English, Chinese, Korean, German Versions)*3*4 Microsoft® Windows® Millennium Edition Operating System (English, Chinese, Korean, German Versions) OS *2*3 Microsoft® WindowsNT® Workstation 4.0 Operating System (English, Chinese, Korean, German Versions) Microsoft® Windows® XP Home Edition Operating System (English, Chinese, Korean, German Versions)*3*4 Microsoft® Windows® 2000 Professional Operating System (English, Chinese, Korean, German Versions)*3 CPU Pentium 200MHz or higher Pentium II 300MHz or higher Required memory 64MB or more 128MB or more Free hard For installation (product only) 250MB or more (For product operation and manual reference: 400MB or more) disk space*1 For operation 200MB or more Disk drive CD-ROM disk drive GT15 simulator: High Color (16-bit) or more Display colors GT11 simulator: 256 colors Display Resolution 800 x 600 dot or more For project data creation/editing GT Designer2*5 • GX Simulator of the following version is required depending on CPU.*6 PLC CPUs to be simulated Software version QCPU (A mode), ACPU or motion controller CPU (A series) Version5 "A" Edition or later Software QCPU (Q mode) (except Q00J/Q00/Q01CPU), QnACPU, FXCPU Version5 "E" Edition or later When GX Simulator is used Q00J/Q00/Q01CPU Q12PHCPU, Q25PHCPU Q12PRHCPU, Q25PRHCPU

*1: A separate available space is required when using GT Designer2, GX Developer, and GX Simulator. *2: Use WindowsNT® Workstation 4.0 with Service Pack3 or later installed. *3: Administrator authority is required to install GT Simulator2 in the following operating systems. • WindowsNT® Workstation 4.0 • Windows® 2000 Professional • Windows® XP Professional • Windows® XP Home Edition

Version6.00A or later Version6.10L or later Version6.20W or later

Moreover, administrator authority is required to use GT Simulator2 in the following operating systems. • Windows® XP Professional • Windows® XP Home Edition *4: The following functions are not supported. • "Compatibility mode", "user account", "desktop appearance", and "remote desktop" *5: Use a GT Designer2 that is included in the same GT Works as GT Simulator2. *6: Use only same-language GT Simulator2, GX Developer, and GX Simulator versions.

55


List of products Model name explanation

Model name explanation (Options)

GT15 9 5

GT 15 - 90 XLTT

Code 9 8 7 6 5 GT15 GT11

-XTBA

Screen size 15" 12.1" 10.4" 8.4" 5.7"

Code Display color 5 256 colors or more 2 16 colors 0 16-tone gray scales

Code None HS

Mounting type Panel mounted type Handy type

Code X S V Q

Resolution XGA (1024 x 768 dot) SVGA (800 x 600 dot) VGA (640 x 480 dot) QVGA (320 x 240 dot)

Full-specification model covering a broad range of applications to be used as stand-alone and network access control. Stand-alone model with full of basic functions.

Code T N S L

Display device TFT color (High-brightness, wide viewing angle) TFT color STN color STN monochrome

Code Power supply specs A 100 to 240VAC D 24VDC

* For inquiries relating to products which conform to UL, cUL, and CE directives, please contact your local sales office.

GT1595

Screen size [resolution] NEW

GT1595-XTBA GT1585-STBA

GT1585

NEW

GT1585-STBD GT1575-STBA

NEW

GT1575-STBD

15" XGA [1024 x 768 dots] 12.1" SVGA [800 x 600 dots] 10.4" SVGA [800 x 600 dots]

GT1575

GT1575-VTBD

NEW

GT1575-VNBA

NEW

GT1575-VNBD

NEW

GT1572-VNBA

NEW

GT1572-VNBD

NEW

TFT color display

GT1562-VNBA

NEW

GT1562-VNBD

NEW

GT1155

GT1155-QSBD

GT1150

GT1150-QLBD

Handy GOT

GT1155HS-QSBD coming soon GT1150HS-QLBD coming soon

256 colors /

Product name

Bus connection unit

Power source Memory size 100-240VAC

TFT color display

Serial communication unit

100-240VAC

(High-brightness, wide viewing angle) 65,536 colors (optional) 24VDC 256 colors /

100-240VAC

RS-422 conversion unit

9MB

Ethernet communication unit MELSECNET/10 communication unit CC-Link communication unit

(High-brightness, wide viewing angle) 65,536 colors (optional) 24VDC 256 colors /

100-240VAC 100-240VAC

256 colors

10.4" VGA [640 x 480 dots]

24VDC

TFT color display

100-240VAC

16 colors

8.4" VGA [640 x 480 dots]

5.7" QVGA [320 x 240 dots]

24VDC

256 colors /

100-240VAC

(High-brightness, wide viewing angle) 65,536 colors (optional) 24VDC 100-240VAC

TFT color display

16 colors

STN color display

256 colors

STN monochrome display

16-tone black/white adjustment

STN color display

256 colors

STN monochrome display

16-tone black/white adjustment

24VDC

Software Version

*1

Version upgrade software (upgrade GT Designer2 to the latest version)

SW2D5C-GTWK2-E SW2D5C-GTWK2-EV

Version upgrade

Version upgrade software (upgrade GT Works2 to the latest version)

SW2D5C-GTD2-E

Version2

SW2D5C-GTD2-EV

GT Works2 Version2

SoftGOT GT SoftGOT2

Version upgrade

A9GTSOFT-LKEY-P

DOS/V License key (for D-sub 25-pin and parallel port)

SW5D5F-SGLKEY-E

License registration package for personal computer CPU unit

*1

Product name

9MB 5MB

3MB

Remarks English version

Multi-color display board

English version 

English version

Protection sheet

Manuals Manual Name

Content Basic software installation information, basic design techniques, and data transfer to a terminal

Data Transfer Manual <For GOT1000 Series> GT Designer2 Version2 Screen Design Manual

Programming manual, including instruction for objects, specifications

<For GOT1000 Series>

Catalog No. SH-080529ENG SH-080530ENG SH-080531ENG

GOT1000 Series Connection Manual

System configurations and procedure to create customized cables

SH-080532ENG

GOT1000 Series Extended/Option Functions Manual

Detailed Extended Functions information

SH-080544ENG

GOT1000 Series Gateway Function Manual

Detailed Gateway Information, including specifications, setting, and configurations

SH-080545ENG

General specification overview, parts and settings, external dimensions, mounting, wiring,

GT15 User's Manual

optional interfaces General specification overview, parts and settings, external dimensions, mounting, wiring,

GT11 User's Manual GOT1000 Handy GOT User's Manual

optional interfaces coming soon

General specification overview, parts and settings, external dimensions, wiring, optional interfaces, in addition to explanations of utility, system configurations, and cable fabrication

SH-080528ENG

USB IP67f rated port cover Emergency stop switch guard

JY997D17501A JY997D20101A

GT Simulator2 Version2 Operation Manual

GT Simulator2 specifications and operating instructions

SH-080546ENG

GT Converter2 Version2 Operation Manual

GT Converter2 operating instructions

SH-080533ENG

Stand

CF card

Memory card adaptor Attachment

56

NEW NEW

NEW NEW NEW NEW NEW

Battery

Model name GT15-90XLTT GT15-80SLTT GT15-70SLTT GT15-70VLTT GT15-70VLTN GT15-60VLTT GT15-60VLTN GT15-FNB GT15-QFNB GT15-QFNB16M GT15-QFNB32M GT15-QFNB48M GT11-50FNB GT15-XHNB GT15-90PSCB GT15-90PSGB GT15-90PSCW GT15-90PSGW GT15-80PSCB GT15-80PSGB GT15-80PSCW GT15-80PSGW GT15-70PSCB GT15-70PSGB GT15-70PSCW GT15-70PSGW GT15-60PSCB GT15-60PSGB GT15-60PSCW GT15-60PSGW GT11-50PSCB GT11-50PSGB GT11-50PSCW GT11-50PSGW GT11H-50PSC GT15-UCOV GT11-50UCOV GT11H-50ESCOV GT15-90STAND GT15-80STAND GT15-70STAND A9GT-50STAND GT05-MEM-32MC GT05-MEM-64MC GT05-MEM-128MC GT05-MEM-256MC GT05-MEM-ADPC GT15-60ATT-96 GT15-60ATT-97 GT15-BAT GT11-50BAT

Specification NEW

Backlight NEW NEW

Optional function board (A/FX ladder monitor) Optional function board (Q/QnA/A/FX ladder monitor)

NEW NEW NEW NEW NEW

NEW

NEW NEW

Applicable model GT15 GT11 Handy GOT                 

Q-BUS (1ch) unit slim model for QCPU (Q-mode) 1 connector Q-BUS (2ch) unit slim model for QCPU (Q-mode) 2 connectors Q-BUS (1ch) unit standard model for QCPU (Q-mode) 1 connector Q-BUS (2ch) unit standard model for QCPU (Q-mode) 2 connectors A-BUS (1ch) unit slim model for QnA/ACPU 1 connector A-BUS (2ch) unit slim model for QnA/ACPU 2 connectors A-BUS (1ch) unit standard model for QnA/ACPU 1 connector A-BUS (2ch) unit standard model for QnA/ACPU 2 connectors RS-232 serial communication unit (D-sub 9-pin (male)) RS-422 / 485 serial communication unit (D-sub, 9-pin (female))*1 RS-422 / 485 serial communication unit (Terminal block)*1 RS-422 connector 9-pin RS-232 → RS-422 conversion unit RS-422 connector 25-pin Ethernet (100Base-TX/10Base-T) unit Optical loop unit Coaxial bus unit Intelligent device station unit

Options

*1: Soon to be supported by the GOT1000 Series. *2: GT SoftGOT2 License key is required for every DOS/V computer, and GT SoftGOT2 license key FD is required for every personal computer CPU unit.

GT Designer2 Version2 Basic Operation/

GT15-75QBUSL GT15-75QBUS2L GT15-QBUS GT15-QBUS2 GT15-75ABUSL GT15-75ABUS2L GT15-ABUS GT15-ABUS2 GT15-RS2-9P GT15-RS4-9S GT15-RS4-TE GT15-RS2T4-9P GT15-RS2T4-25P GT15-J71E71-100 GT15-75J71LP23-Z *2 GT15-75J71BR13-Z *2 GT15-75J61BT13-Z *2

Specification

5MB

Optional function board

Version upgrade Version upgrade Version upgrade

GT Designer2

License key for GT SoftGOT2 *1*2 License key FD for GT SoftGOT2 *1*2

Included product Drawing Software Simulation Version upgrade Easy data conversion GT Designer2 Ver. 2 GT Simulator2 Ver. 2 GT Converter2 Ver. 2

Model name

*1: The unit maybe unusable depending on the connection destination. For details, see the "Connection configuration" section from page 32 and relevant manuals. *2: All units other than MELSECNET/10 and CC-Link communication units conform to CE / UL/ cUL.

Software Software

Specification 15" 12.1" Common to 15", 12.1", 10.4", and 8.4". 10.4" 8.4" 5.7"

5MB

Backlight 24VDC

Common to both GT15 and GT11

Code 90 80 75 70 60 50

Applicable model GT15 GT11 Handy GOT

For 15" type High-brightness, wide viewing angle TFT (XGA) For 12.1" type High-brightness, wide viewing angle TFT (SVGA) For 10.4" type High-brightness, wide viewing angle TFT (SVGA) For 10.4" type High-brightness, wide viewing angle TFT (VGA) For 10.4" type TFT (VGA) For 8.4" type High-brightness, wide viewing angle TFT (VGA) For 8.4" type TFT (VGA) (Without expansion memory) (Without expansion memory) 16MB expansion memory 32MB expansion memory 48MB expansion memory

Optional function board Multi-color display board for 65536 color display Clear (Set of 5) Anti-glare (Set of 5) Protection sheet for 15" type Clear with white frame (Set of 5) Anti-glare with white frame (Set of 5) Clear (Set of 5) Anti-glare (Set of 5) Protection sheet for 12.1" type Clear with white frame (Set of 5) Anti-glare with white frame (Set of 5) Clear (Set of 5) Anti-glare (Set of 5) Protection sheet for 10.4" type Clear with white frame (Set of 5) Anti-glare with white frame (Set of 5) Clear (Set of 5) Anti-glare (Set of 5) Protection sheet for 8.4" type Clear with white frame (Set of 5) Anti-glare with white frame (Set of 5) Clear (Set of 5) Anti-glare (Set of 5) Protection sheet for 5.7" type Clear with white frame (Set of 5) Anti-glare with white frame (Set of 5) Protection sheet for 5.7" type (For Handy GOT) Clear (Set of 5)

IP67f rated port cover (for replacement) for unit front USB interface

 

To prevent operational error Debugging stand for 15" type Debugging stand for 12.1" type Debugging stand for 8.4"/10.4" type Debugging stand for 5.7" type 32MB Flash ROM 64MB Flash ROM 128MB Flash ROM 256MB Flash ROM CF card → memory card (TYPE II) conversion adaptor A960GOT→ GT1565/GT1562 Attachment for 8.4" type A97 GOT→ GT1565/GT1562 Data backup battery for clock and maintenance notification Data backup battery for clock, alarm history, and recipes

                

    

           

           

                

                    

     

   

List of products

GT11

NEW

256 colors /

(High-brightness, wide viewing angle) 65,536 colors (optional)

TFT color display

GT1565-VTBD

Display color

(High-brightness, wide viewing angle) 65,536 colors (optional) 24VDC

GT1565-VTBA GT1565

TFT color display

TFT color display

GT1575-VTBA GT15

Display device

Model name GT15 GT11 Handy GOT

Communication interface

GOT main units Model name

Code 15 11 11H 09 05 01

     

  

57


List of products

Cables

Cables for other brand PLC Product name

Model name

Cable 3rd party length products*1

GT15-QC06B

0.6m

GT15-QC12B

1.2m

GT15-QC30B

3m

GT15-QC50B

5m

cable

GT15-QC100B

10m

(For QCPU (Q mode))

GT15-QC150BS

15m

GT15-QC200BS

20m

For long-distance (13.2m or more) connection

GT15-QC250BS

25m

between QCPU and GOT (A9GT-QCNB required)

GT15-QC300BS

30m

For connection between GOT and GOT

GT15-QC350BS

35m

QCPU extension cable Q bus connection

Inter-GOT connection cable

QCPU long-distance connection cable Inter-GOT long-distance connection cable

Bus extension connector box

Large CPU extension cable

A bus connection cable

Small CPU extension cable

A9GT-QCNB

GT15-C12NB

1.2m

GT15-C30NB

3m

GT15-C50NB

5m

GT15-AC06B

0.6m

GT15-AC12B

1.2m

GT15-AC30B

3m

GT15-AC50B

5m (A series/main base) and GOT For connection between motion controller CPU

GT15-A370C25B

2.5m

(A series/main base) and A7GT-CNB

GT15-A1SC07B

0.7m

GT15-A1SC12B

1.2m

GT15-A1SC30B

3m

(A series))

GT15-A1SC07NB

0.7m

GT15-A1SC30NB

3m

GT15-C300EXSS-1

30.6m

3m 5m

GT15-C100BS

10m

GT15-C200BS

20m

GT15-C300BS

30m

A0J2HCPU connection cable GT15-J2C10B

1m

Bus connector conversion box

A7GT-CNB

Buffer circuit cable

GT15-EXCNB

connection cable Computer link connection cable RS-422 cable

FXCPU direct connection cable FX communication function extension board connection cable QCPU direct connection cable Data transmission cable

Used for QnA/ACPU long-distance bus connection Can be used with GT15-C BS as GT15-C EXSS-1

GT01-C200R4-25P

20m

For connection between FA-CNV CBL and GOT.

GT01-C300R4-25P

30m

For connection between serial communication unit and GOT

3m

GT01-C100R4-8P

10m

GT01-C200R4-8P

20m

GT01-C300R4-8P

30m

GT01-C30R2-6P

3m

For connection between FXCPU (MINI-DIN 8-pin connector) and GOT. For connection between FXCPU communication function extension board and GOT.

For connection between personal computer (drawing software) (D-sub 9-pin: female) and GOT (MINI-DIN 6-pin: female) *Handy GOT only connector) and GOT.

GT01-C30R2-9S

3m

(D-sub 9-pin connector) and GOT. For connection between personal computer (drawing software) (D-sub 9-pin: female) and

Data transmission cable

GOT (D-sub 9-pin: female) For connection between FXCPU communication function adaptor (D-sub GT01-C30R2-25P

3m

operation switch connection cable

RS-422, power supply, FA device

operation switch

connection

connection cable

operation switch connection cable Data transmission cable

Cable for Hitachi Industrial Equipment Systems PLC

25-pin connector) and GOT. For connection between personal computer (drawing software) (D-sub 25-pin: male) and GOT (D-sub 9-pin: female)

GT11H-C30-37P

coming soon

GT11H-C60-37P

coming soon

6m

GT11H-C100-37P

coming soon

10m

GT11H-C30

coming soon

3m

GT11H-C60

coming soon

6m

GT11H-C100

coming soon

10m

GT11H-C15R4-8P

coming soon

1.5m

GT11H-C15R4-25P

coming soon

1.5m

GT11H-C15R2-6P

coming soon

1.5m

3m

relay cable RS-232, power supply,

Cable for TOSHIBA PLC

For connection between FXCPU communication function adaptor

adaptor connection cable

FA device, power supply,

RS-422 cable

For connection between QCPU and GOT *Excluding Handy GOT

extension board connection FX communication function

Cable for SHARP PLC

For connection between QnA/ACPU/motion controller CPU (A series)/FXCPU (D-sub 9-pin connector) and GOT.

Data transmission cable

USB cable

For connection between A0J2HCPU power supply unit (A0J2-PW) and GOT

FX communication function

adaptor connection cable

connection cable

For connection between GOT and GOT

10m

FX communication function

External

Cable for KEYENCE PLC

GT01-C100R4-25P

GT01-C30R4-8P

GT09-C20USB-5P

2m

GT09-C30R20402-15P GT09-C30R20901-25P

coming soon

GT09-C30R20903-9P GT09-C30R20904-3C GT09-C30R20201-9P GT09-C30R20202-15P GT09-C30R20203-9P GT09-C30R20204-14P GT09-C30R20205-25P

3m 3m 3m 3m 3m

HMI adaptor

3m 3m 3m 3m 3m 3m 3m 3m 3m 3m

coming soon

3m 3m 3m

GT09-C30R20902-9P

GT09-C30R20801-9S

For connection between GOT and GOT

3m

1m

coming soon

coming soon

For connection between FA device connection relay cable and GOT

Cable for Yaskawa Electric PLC

For connection between FA device, power supply, operation switch and GOT For connection between FXCPU and GOT For connection between power supply, operation switch and GOT For connection between A/QnACPU and GOT For connection between power supply, operation switch and GOT For connection between QCPU and GOT For connection between power supply, operation switch and GOT For connection between personal computer (drawing software) (USB) and GOT (USB Mini-B)

*1: Items listed above are developed by Mitsubishi Electric System & Service Co., LTD., and sold through your local sales office.

Cable for Yokogawa Electric PLC

GT09-C30R40101-9P GT09-C100R40101-9P GT09-C200R40101-9P GT09-C300R40101-9P GT09-C30R40102-9P GT09-C100R40102-9P GT09-C200R40102-9P GT09-C300R40102-9P GT09-C30R41101-5T GT09-C100R41101-5T GT09-C200R41101-5T GT09-C300R41101-5T GT09-C30R40601-15P GT09-C100R40601-15P GT09-C200R40601-15P GT09-C300R40601-15P GT09-C30R40602-15P GT09-C100R40602-15P GT09-C200R40602-15P GT09-C300R40602-15P GT09-C30R40603-6T GT09-C100R40603-6T GT09-C200R40603-6T GT09-C300R40603-6T GT09-C30R40501-15P GT09-C100R40501-15P GT09-C200R40501-15P GT09-C300R40501-15P GT09-C30R40502-6C GT09-C100R40502-6C GT09-C200R40502-6C GT09-C300R40502-6C GT09-C30R40503-15P GT09-C100R40503-15P GT09-C200R40503-15P GT09-C300R40503-15P GT09-C30R40401-7T GT09-C100R40401-7T GT09-C200R40401-7T GT09-C300R40401-7T GT09-C30R40201-9P GT09-C100R40201-9P GT09-C200R40201-9P GT09-C300R40201-9P GT09-C30R40202-14P GT09-C100R40202-14P GT09-C200R40202-14P GT09-C300R40202-14P GT09-C30R40301-6T GT09-C100R40301-6T GT09-C200R40301-6T GT09-C300R40301-6T GT09-C30R40302-6T GT09-C100R40302-6T GT09-C200R40302-6T GT09-C300R40302-6T

coming soon

coming soon coming soon coming soon coming soon

GOT connection destination PLC CPU: CQM1/CQM1H/CS1/CJ1/CV500/CV1000/CV2000/CVM1 Serial communication unit: CS1W-SCU21 Communication board: C200HW-COM2/COM05/COM06 Serial communication board: CQM1-SCB41/CS1W-SCB41/CS1W-SCB21 Connection cable: CQM1-CIF01 Base mounted type upper link unit: C500H-LK201-V1 PLC CPU: KV-700/1000 Communication unit: KV-L20/L20R port1 Communication unit: KV-L20/L20R port2 PLC CPU: JW-22CU/70CUH/100CUH/100CU PLC CPU: JW-32CUH/33CUH PLC CPU: T2E PLC CPU: T2N PLC CPU: H-4010/H series board type/EH-150 series Intelligent serial port module: COMM-H/COMM-2H PLC CPU: H-4010/EH-150 series RS-422/232 conversion adaptor: AFP8550 PLC CPU: FP2/FP2SH/FP10(S)/FP10SH/FP-M Computer communication unit: AFP2462/AFP3462/AFP5462 PLC CPU: FP1-C24C/C40C PLC CPU: FP1-C16CT/C32CT PLC CPU: PROGIC-8/MP-920/MP-930 PLC CPU: PROGIC-8 PLC CPU: CP-9300MS MEMOBUS module: CP-217IF PLC CPU: MP-940 MEMOBUS module: CP-217IF Yokogawa Electric personal computer module: LC01-0N/LC02-0N CPU port/D-sub 9-pin conversion cable: KM10-0C Personal computer module: F3LC11-1N/F3LC11-1F/F3LC12-1F/F3LC11-2N PLC CPU: SL500 series Converter: 1761-NET-AIC Adaptor: 1770-KF3

3m

GT09-C30R20401-15P

SIEMENS PLC

*Combination of GT15-EXCNB and GT15-C BS

GT01-C30R4-25P

GT01-C10R4-8P

GT09-C30R20102-25S GT09-C30R20103-25P GT09-C30R21101-6P GT09-C30R21102-9S GT09-C30R21103-3T GT09-C30R20601-15P GT09-C30R20602-15P GT09-C30R20501-9P GT09-C30R20502-15P

GT09-C30R20301-9P GT09-C30R20302-9P GT09-C30R20701-9S GT09-C30R20702-25P

Cable for OMRON PLC

For connection between A7GT-CNB and GOT (Long distance)

For connection between FXCPU communication function extension board (D-sub 9-pin

cable RS-232 cable

 0.5m

GT09-C30R20101-9P

Cable for Yokogawa Electric PLC Cable for Allen-Bradley PLC

For connection between QnAS/AnSCPU and A7GT-CNB and GOT (Long distance)

GT15-C50BS

QnA/A/FXCPU direct

(A series) and A7GT-CNB

20.6m

1.2m

connection cable

For connection between QnAS/AnSCPU/motion controller CPU

GT15-C200EXSS-1

GT15-C30BS

Inter-GOT long-distance

For connection between QnAS/AnSCPU and GOT

For connection between QnAS/AnSCPU/motion controller CPU (A series)

GT15-C12BS

Inter-GOT connection cable

(A series) and GOT

10.6m

0.7m

Cable 3rd party length products*1

Model name

3m 3m 3m 3m 3m 3m 3m

For connection between QnAS/AnSCPU/motion controller CPU

GT15-C100EXSS-1

GT15-C07BS

Cable for Yaskawa Electric PLC

NEW

3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m 3m 10m 20m 30m

PLC CPU: CV500/CV1000/CV2000/CVM1 Communication board: C200HW-COM03/COM06 Serial communication board: CQM1-SCB41/CS1W-SCB41

Base mounted type upper link unit: C200H-LK202-V1/C500H-LK201-V1

Communication unit: KV-L20/L20R port2

Applicable model GT15 GT11 Handy GOT

List of products

connection cable

5m

Cable for SHARP PLC Cable for TOSHIBA PLC Cable for Hitachi Industrial Equipment Systems PLC Cable for Matsushita Electric Works PLC

(A series/extension base) and A7GT-CNB

1.2m

5m

RS-232 cable

For connection between QnA/ACPU/motion controller CPU

GT15-A370C12B

0.45m

Small CPU long-distance

(A series/extension base) and GOT

For connection between motion controller CPU

GT15-A1SC05NB Small CPU extension cable

For connection between QnA/ACPU/motion controller CPU

2.5m

GT15-A1SC50B

Cable for KEYENCE PLC

Used for QCPU long-distance (13.2m or more) bus connection

1.2m

motion controller

Cable for OMRON PLC

For connection between GOT and GOT

GT15-A370C25B-S1

(For QnA/ACPU/

Product name

GT15 GT11 Handy GOT

For connection between QCPU and GOT

GT15-A370C12B-S1

GT15-A1SC50NB

58

Specification

Applicable model

PLC CPU: JW-22CU/70CUH/100CUH/100CU

PLC CPU: JW-32CUH/33CUH

Link unit: JW-21CM/10CM/ZW-10CM

PLC CPU: T2/T3/T3H/model3000(S3)

PLC CPU: T2E

PLC CPU: T2N

Intelligent serial port module: COMM-H/COMM-2H

MEMOBUS module: JAMSC-120NOM27100/JAMSC-IF612

PLC CPU: MP940

Personal computer link module: F3LC11-2N

Personal computer link module: LC01-0N/LC02-0N

*1: Items listed above are developed by Mitsubishi Electric System & Service Co., LTD., and sold through your local sales office. *2: RS-422 conversion unit (GT15-RS2T4-9P) is required.

59


Memo

60

Memo

61


Mitsubishi Graphic Operation Terminal Precautions for Choosing the Products

For safe use • To use the products given in this catalog properly, always read the "manuals" before starting to use them. • This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life. • Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi. • This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

This catalog explains the typical features and functions of the GOTs and does not provide restrictions and other information on usage and module combinations. When choosing the products, always check the detailed specifications, restrictions, etc. of the products in the user's manuals. When using the products, always read the user's manuals of the products. Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.

Country/Region Sales office

Tel/Fax

U.S.A

Mitsubishi Electric Automation Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061

Tel : +1-847-478-2100 Fax : +1-847-478-2396

Brazil

MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Rua Correia Dias,184, Edificio Paraiso Trade Center-8 andar Paraiso, Sao Paulo, SP Brazil

Tel : +55-11-5908-8331 Fax : +55-11-5574-5296

Germany

Mitsubishi Electric Europe B.V. German Branch Gothaer Strasse 8 D-40880 Ratingen, GERMANY

Tel : +49-2102-486-0 Fax : +49-2102-486-7170

U.K

Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Herts., AL10 8XB,UK

Tel : +44-1707-276100 Fax : +44-1707-278695

Italy

Mitsubishi Electric Europe B.V. Italian Branch Centro Dir. Colleoni, Pal. Perseo - Ingr.2 Via Paracelso 12, 20041 Agrate B., Milano, Italy

Tel : +39-039-60531 Fax : +39-039-6053312

Spain

Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi 76-80 08190 Sant Cugat del Valles, Barcelona, Spain

Tel : +34-93-565-3131 Fax : +34-93-589-2948

France

Mitsubishi Electric Europe B.V. French Branch 225 Boulevard des Bouvets, F-92741 Nanterre Cedex, France

Tel : +33-1-5568-5568 Fax : +33-1-5568-5685

South Africa

Circuit Breaker Industries LTD Private Bag 2016, 1600 Isando, Tripswitch Drive, Elandsfontein Gauteng, South Africa

Tel : +27-11-928-2000 Fax : +27-11-392-2354

Hong Kong

Mitsubishi Electric Automation (Hong Kong) Ltd. 10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong

Tel : +852-2887-8870 Fax : +852-2887-7984

China

Mitsubishi Electric Automation (Shanghai) Ltd. 1-3/F., Block5, 103 Cao Bao Road, Shanghai 200233, China

Tel : +86-21-6475-3228 Fax : +86-21-6474-6996

Taiwan

Setsuyo Enterprise Co., Ltd. 6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan

Tel : +886-2-2299-2499 Fax : +886-2-2299-2509

Korea

Mitsubishi Electric Automation Korea Co., Ltd. Dong seo Game Channel Bldg. 2F 660-11, Deungchon-dong, Kangseo-ku, Seoul 157-030, Korea

Tel : +82-2-3660-9552 Fax : +82-2-3664-8372

Singapore

Mitsubishi Electric Asia Pte, Ltd. 307 Alexandra Road #05-01/02, Mitsubishi Electric Bulding Singapore 159943

Tel : +65-6470-2460 Fax : +65-6476-7439

Thailand

F.A. Tech Co., Ltd. 896/19, 20, 21, 22, S. V. City Building, Office Tower 1, Floor 12 Rama III Rd, Bangpongpang, Yannawa, Bangkok 10120

Tel : +66-2-682-6522 Fax : +66-2-682-6020

Indonesia

Indonesia P.T. Autoteknindo SUMBER MAKMUR Muara Karang Selatan Block A/Utara No.1 Kav. No.11 Kawasan Industri/Pergudangan Jakarta-Utara 14440

Tel : +62-21-663-0833 Fax : +62-21-663-0832

India

Messung Systems Pvt, Ltd. Electronic Sadan NO:111 Unit No15, M.I.D.C Bhosari, Pune-411026, India

Tel : +91-20-2712-3130 Fax : +91-20-2712-8180

Australia

Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, Rydalmere, N.S.W 2116, Australia

Tel : +61-2-9684-7777 Fax : +61-2-9684-7245

ELECTRIC CORPORATION HEAD OFFICE: 1-8-12,OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN NAGOYA WORKS: 1-14,YADA-MINAMI 5, HIGASHI-KU, NAGOYA, JAPAN

When exported from Japan, this manual does not require application to the Ministry of International Trade and Industry for service transaction permission.

L(NA)08054E-B 0511(MDOC)

New publication, effective November, 2005 Specifications subject to change without notice.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.