Welcome to Membrane for industrial Water Filtration, Catalog # MemEN201505. This catalog provides a comprehensive resource for users needing Membrane elements. This catalog contains membranes from major sources like Filmtec, Hydranautic, KOCH and Toray in which covers Reverse Osmosis, Nano Filtration and Ultrafiltrative in may kinds of format to supplies your needs.

Trademarks of Other Manufactures The following trademarks and referring to herein are the high quality products that we also offer or correspond with. FilmtecTM iLECTM FullFitTM ESPA® CPA® LFC® SWC® HYDRAcap® SelRO® TFC® SPIRAPROTM ROMIPROTM Super-Cor

Membrane

We would like to thank you for your interest in our products. Please feel free to contact our customer service team for inquiries, orders, technical problems and more application supports.

2

©2015 Acropore Technology Co.,Ltd. All rights reserved. Specifications subject to change without notice.

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Dow Chemicals Dow Chemicals Dow Chemicals Hydranautics Hydranautics Hydranautics Hydranautics Hydranautics Koch Koch Koch Koch Koch


Table of Contents Filmtec Membrane

2-11

Tape Wrapped Elements for Commercial Applications

2

Fiberglass Elements for Commercial Systems

3

Brackish Water Elements for Industrial Applications

4

iLECTM Interlocking Style Brackish Water Elements

5

Seawater RO Elements for Marine Systems

6

Seawater RO Elements for Industrial Systems

7

iLEC Seawater RO Elements for Industrial Systems

8

Full Fit & Heat Sanitizable Membrane Elements

9

Nanofiltration Membrane Elements

10

Hollow Fiber Ultrafiltration Modules

11

TM

Hydranautics Membrane

12-17

ESPA® Ultra Low Pressure Membrane Elements

12

CPA High Rejection Membrane Elements

13

LFC® Low Fouling Membrane Elements

14

SWC® Seawater Membrane Elements

15

Nanofiltration Membrane Elements

16

HYDRAcap® Ultrafiltration Modules

17

Koch Membrane

18-25 18

XR Series – Extra High Rejection Thin Film Elements

19

HRX Series - Food & Dairy Sanitary RO Elements

20

SW Series – Seawater Elements

21

SelRO® MPS Series - pH Stable Nanofiltration Membrane

22

SPIRAPRO Series – Pharmaceutical Grade NF Elements

23

ROMIPRO Seies - Hollow Fiber Cartridges for Foood and Pharmaceutical Applicaions

24

Super-Cor Series - Ultrafiltration Tabular Multitube Modules for Juice and Beverage Processing

25

Toray Membrane

26-35

TM700 Series - High Rejection RO Elements for high salinity brackish water applications

26

TMG, TMH Series - Ultra Low Pressure RO Elements for low salinity brackish water applications

27

TM800 Series - High Rejection RO Elements for sea water applications

28

TML Series - Low Fouling RO Elements for high fouling potential water applications

29

TMRO Series - Sanitary RO Elements for Pharmaceutical, Food and Beverage applications

30

TNF Series - Sanitary NF Elements for Pharmaceutical, Food and Beverage applications

31

TUF Series - Sanitary UF Elements for Dairy applications

32

HF Series - Hollow fiber Ultrafiltratiom Modules for sea water applications

33

Membrane Cleaners

34-35

Membrane Cleaning Chemicals

34

Membrane Cleaning System

35

sales@acropore.com

Membrane

HR Series - High Rejection Low Pressure Thin Film Elements

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

3


FILMTEC™ Membrane Elements Tape Wrapped Elements for Commercial Applications • FILMTEC TW30 is the industry standard for reliable operation and production of the highest quality water. • FILMTEC XLE is the most productive, lowest pressure RO membrane available, delivering the lowest total system cost. • FILMTEC LP delivers high quality water at low pressure operation. LP replaces many “first generation” low pressure membrane elements and will purify more water in many older systems, especially on cold water feeds. Tape-wrapped elements are built with the same high quality membranes and materials of construction as industrial elements, except for the hard outershell, and are more economical for commercial systems with one or two elements per housing. Operating Contditions Membrane Type Maximum Operating Temperature Feed water pH Range, Continuous Operation1 Feed water pH Range, Short-Term Cleaning (30 minutes) Maximum Feed water Silt Density Index (SDI) Free Chlorine Tolerance2 Maximum Pressure Drop Maximum Operating Pressure

Polyamide Thin-Film Composite 45°C 2-11 1-13 5 < 0.1 ppm 13 psig (0.9 bar) 600 psig (41 bar)

Membrane

1: Maximum temperature for continuous operation above pH 10 is 35°C. 2: Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, FilmTec recommends removing residual free chlorine by pretreatment prior to membrane exposure.

Dimension Model No. TW30-2026 TW30-2514 TW30-2521, XLE-2521 TW30-2540, XLE-2540, LP-2540 TW30-4014 TW30-4021, XLE-4021 TW30-4040, XLE-4040, LP-4040

Max. Feed Flow Rate gpd lpd 5 1100 6 1400 6 1400 6 1400 14 3200 14 3200 14 3200

A inch 26.0 14.0 21.0 40.0 14.0 21.0 40.0

B mm 660 356 533 1016 356 533 1016

inche 1.18 1.19 1.19 1.19 1.05 1.05 1.05

C mm 30 30 30 30 27 27 27

inche 0.68 0.75 0.75 0.75 0.75 0.75 0.75

D mm 17 19 19 19 19 19 19

inche 1.8 2.4 2.4 2.4 3.9 3.9 3.9

mm 46 61 61 61 99 99 99

Ordering information Model No. TW30-2026 TW30-2514 TW30-2521 TW30-2540 TW30-4014 TW30-4021 TW30-4040 LP-2540 LP-4040 XLE-2521 XLE-2540 XLE-4021 XLE-4040

Permeate Flow Rate gpd3 lpd4 220 830 200 760 325 1230 850 3200 525 1990 900 3410 2400 9100 1000 3800 2900 11000 365 1380 850 3200 1025 3880 2600 9800

lph5 35 30 50 130 80 140 380 160 460 60 130 160 400

Dia × Length (inch) 2.0 × 26 2.5 × 14 2.5 × 21 2.5 × 40 4.0 × 14 4.0 × 21 4.0 × 40 2.5 × 40 4.0 × 40 2.5 × 21 2.5 × 40 4.0 × 21 4.0 × 40

Active Surface Area (Sq. Ft.) 7 7 13 28 20 36 78 28 78 13 28 36 87

Single Element Applied Pressure Stabilized Salt Recovery (%) (psi) Rejection (%) 10 225 99.5 5 225 99.5 8 225 99.5 15 225 99.5 5 225 99.5 8 225 99.5 15 225 99.5 8 145 99.0 8 145 99.2 10 100 99.0 15 100 99.0 5 100 99.0 15 100 99.0

3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

2

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com


FILMTEC™ Membrane Elements Fiberglass Elements for Commercial Systems • Permeate flow and salt rejection based on the following test conditions: 2,000 ppm NaCl, applied pressure as above, 25°C and 15% recovery. • Permeate flows for individual elements may vary ±20%. • For the purpose of improvement, specifications may be updated periodically. • LE-4040 replaces BW30LE-4040. FILMTEC™ brackish water reverse osmosis membrane elements provide consistent, outstanding system performance in light industrial applications. FILMTEC™ LE delivers highest performance at lowest pressure resulting in less energy usage and lower costs. FILMTEC BW30 is the industry standard for reliable operation and production of the highest quality water

Operating Contditions Membrane Type Maximum Operating Temperature Maximum Operating Pressure Maximum Pressure Drop Maximum Feed Flow Rate

Polyamide Thin-Film Composite 45°C 600 psig (41 bar) 15 psig (1 bar) 2.5” x 40” Elements: 6 gpm (1400 lph) 4” x 40” Elements: 16 gpm (3600 lph) 2-11 1-13 5 < 0.1 ppm

Feed water pH Range, Continuous Operation1 Feed water pH Range, Short-Term Cleaning (30 minutes) Maximum Feed water Silt Density Index (SDI) Free Chlorine Tolerance2

Membrane

1: Maximum temperature for continuous operation above pH 10 is 35°C. 2: Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, FilmTec recommends removing residual free chlorine by pretreatment prior to membrane exposure.

Dimension A

Model No. BW30-2540 BW30-4040, LE-4040, LC LE-4040, LC HR-4040

B

inches 40.0 40.0

mm 1016 1016

lph5 130 380 400 400 460

Dia × Length (inches) 2.5 × 40 4 × 40 4 × 40 4 × 40 4 × 40

inches 1.19 1.05

C mm 30 27

inches 0.75 0.75

D mm 19 19

inches 2.4 3.9

mm 61 99

Ordering information Model No. BW30-2540 BW30-4040 LE-4040 LC LE-4040 LC HR-4040

Permeate Flow Rate gpd3 lpd4 850 3200 2400 9100 2500 9500 2500 9500 2900 11000

Active Surface Area (Sq. Ft.) 28 78 78 94 94

Single Element Applied Pressure Recovery (%) (psi) 34 225 34 225 28 150 15 125 15 225

Stabilized Salt Rejection (%) 99.5 99.5 99.0 99.1 99.5

3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

3


FILMTEC™ Membrane Elements Brackish Water Elements for Industrial Applications • FILMTEC BW30 is the element of choice for systems requiring consistently high performance and the highest quality permeate. • FILMTEC XLE is the most productive, lowest pressure RO membrane available, delivering the lowest total system cost. • FILMTEC BR-30FR are fouling resistant elements designed to purify water with high biological or organic fouling potential in systems with well-controlled pretreatment and offer superior fouling resistance and clean ability

Operating Contditions Membrane Type Maximum Operating Temperature Maximum Operating Pressure Maximum Pressure Drop Maximum Feed Flow Rate Feed water pH Range, Continuous Operation1 Feed water pH Range, Short-Term Cleaning (30 minutes) Maximum Feed water Silt Density Index (SDI) Free Chlorine Tolerance2

Polyamide Thin-Film Composite 45°C 600 psig (41 bar) 15 psig (1 bar) 85 gpm (19,000 lph) 2-11 1-13 5 < 0.1 ppm

Membrane

1: Maximum temperature for continuous operation above pH 10 is 35°C. 2: Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, FilmTec recommends removing residual free chlorine by pretreatment prior to membrane exposure.

Dimension A

Model No. BW30-FR-365, BW30FR-400, LE-400 XLE-440

inch 40 40

B mm 1016 1016

inch 1.125 1.500

C mm 29 38

inch 7.9 7.9

mm 201 201

Inlet Connector (one included) PV-IN810 PV-IN810LE

Ordering information Model No. BW30-365 BW30-365-IG* BW30-400 BW30-400-IG* XLE-440 LE-400 BW30FR-400 BW30FR-365

Permeate Flow Rate lpd4 gpd3 9,500 36,000 9,500 36,000 10,500 40,000 10,500 40,000 14,000 53,000 11,500 44,000 10,500 40,000 9,500 36,000

lph5 1,500 1,500 1,600 1,600 2,200 1,800 1,600 1,500

OD × L (inch) 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40

Active Surface Feed Spacer Applied Area (Sq. Ft.) Thickness (mil) Pressure (psi) 365 34 225 365 34 225 400 28 225 400 28 225 440 28 125 400 34 150 400 28 225 365 34 225

Minimum Salt Stabilized Salt Rejection (%) Rejection (%) 99.0 99.5 99.0 99.5 99.0 99.5 99.0 99.5 99.0 99.5 99.0 99.5 99.0 99.5 99.0 99.5

*Industrial Grade (IG) elements are designed for use in industrial water treatment applications. They maintain the same flow and rejection performance of the equivalent elements, but do not carry the ANSI standard 61 or KIWA certifications, offering a more cost effective option for industrial applications. 3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

4

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com


FILMTEC™ Membrane Elements iLECTM Interlocking Style Brackish Water Elements A variety of FILMTEC elements are now available with iLEC interlocking end caps, an innovative element coupling technology that significantly enhances the performance of RO systems. Instead of using interconnectors to couple membranes end-to-end within a vessel, interlocking end caps twist directly together, reducing the number of sealing surfaces to a single axially compressed O-ring. The design reduces the potential for seal leakage, enabling sustained higher quality permeate, and reduces energyconsuming flow resistance, resulting in lower operating costs. FILMTEC BW30 is the element of choice for systems requiring consistently high performance and the highest quality permeate. FILMTEC BW30HR is a high productivity, high rejection RO membrane, with 99.7% Stabilized Salt Rejection FILMTEC LE Low Energy Elements are designed to deliver high quality water at 40% lower feed pressure to reduce energy and operating cost in municipal and industrial water applications. FILMTEC FR fouling resistant elements are designed to purify water with high biological or organic fouling potential in systems with well-controlled pretreatment and offer superior fouling resistance and cleanability.

Operating Contditions Membrane Type Maximum Operating Temperature Maximum Operating Pressure Maximum Pressure Drop Maximum Feed Flow Rate Feed water pH Range, Continuous Operation1 Feed water pH Range, Short-Term Cleaning (30 minutes) Maximum Feed water Silt Density Index (SDI) Free Chlorine Tolerance2

Membrane

Polyamide Thin-Film Composite 45°C 600 psig (41 bar) 15 psig (1 bar) 85 gpm (19,000 lph) 2-11 1-13 5 < 0.1 ppm

1: Maximum temperature for continuous operation above pH 10 is 35°C. 2: Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, FilmTec recommends removing residual free chlorine by pretreatment prior to membrane exposure.

Dimension A

Model No. All models

inch 40

B mm 1,016

inch 40.5

C mm 1,029

inch 7.9

D mm 201

inch 1.125

mm 29

Ordering information Model No. BW30-400/34i BW30-440i BW30HR-440i LE-440i HRLE-440i BW30XFR-400/34i BW30FR-400/34i XFRLE-400/34i

Permeate Flow Rate lpd4 gpd3 10,500 40,000 11,500 43,000 12,650 48,000 12,650 48,000 12,650 48,000 11,500 43,000 10,500 40,000 11,500 43,000

lph5 1,600 1,800 2,000 2,000 2,000 1,800 1,600 1,800

OD × L (inch) 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40 8 x 40

Active Surface Feed Spacer Applied Area (Sq. Ft.) Thickness (mil) Pressure (psi) 400 34 225 440 28 225 440 28 225 440 28 150 440 28 150 440 34 225 440 34 225 440 34 225

Minimum Salt Stabilized Salt Rejection (%) Rejection (%) 99.0 99.5 99.0 99.5 99.4 99.7 99.0 99.3 99.5 99.3 99.4 99.65 99.0 99.5 99.4 99.2

3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

5


FILMTEC™ Membrane Elements Seawater RO Elements for Marine Systems Designed to convert Seawater to Drinking Water in land and sea-based desalinators, the improved FILMTEC seawater reverse osmosis elements offer the highest productivity while maintaining excellent salt rejection in seawater desalination systems. FILMTEC seawater RO Elements can be used in water makers for seawater desalination in shipboard applications FILMTEC SW30 membrane elements have the highest flow rates available to meet the water demands of both sea-based and land-based desalinators. FILMTEC SW30 elements may also be operated at lower pressure to reduce pump size, cost and operating expenses.

Operating Contditions Membrane Type Maximum Operating Temperature Maximum Operating Pressure Maximum Pressure Drop Feed water pH Range, Continuous Operation1 Feed water pH Range, Short-Term Cleaning (30 minutes) Maximum Feed water Silt Density Index (SDI) Free Chlorine Tolerance2

Polyamide Thin-Film Composite 45°C 1000 psig (69 bar), SW30HRLE: 1,200psig 15 psig (1 bar) 2-11 1-13 5 < 0.1 ppm

Membrane

1: Maximum temperature for continuous operation above pH 10 is 35°C. 2: Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, FilmTec recommends removing residual free chlorine by pretreatment prior to membrane exposure.

Dimension Model No. SW30-2514 SW30-2521 SW30-2540 SW30-4021 SW30-4040, SW30HRLE-4040

Max. Feed Flow Rate gpd lpd 6 1.4 6 1.4 6 1.4 14 3.2 14 3.2

A inch 14.0 21.0 40.0 21.0 40.0

B mm 356 533 1016 533 1016

inche 1.19 1.19 1.19 1.05 1.05

C mm 30 30 30 27 27

inche 0.75 0.75 0.75 0.75 0.75

D mm 19 19 19 19 19

inche 2.4 2.4 2.4 3.9 3.9

mm 61 61 61 99 99

Ordering information Model No. SW30-2514 SW30-2521 SW30-2540 SW30-4021 SW30-4040

Permeate Flow Rate lpd4 gpd3 150 600 300 1,100 700 2,600 800 3,000 1,950 7,400

lph5 25 45 108 125 308

OD × L (inch) 2.5 × 4 2.5 × 4 2.5 × 4 4 x 21 4 × 40

Active Surface Area (Sq. Ft.) 6.5 13 29 33 80

Feed Spacer Thickness (mil) 2 4 8 4 8

Applied Pressure (psi) 800 800 800 800 800

Stabilized Salt Rejection (%) 99.4 99.4 99.4 99.4 99.4

*Industrial Grade (IG) elements are designed for use in industrial water treatment applications. They maintain the same flow and rejection performance of the equivalent elements, but do not carry the ANSI standard 61 or KIWA certifications, offering a more cost effective option for industrial applications. 3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

Ordering information Model No. SW30HRLE-4040

Permeate Flow Rate Salt Rej (%) OD × L Active Surface Feed Spacer Applied lpd4 lph5 (inch) Area (Sq. Ft.) Thickness (mil) Pressure (psi) Stab. Min. gpd3 1,600 610 25.5 4 × 40 85 8 800 99.4 99.6

Boron Rej (%) Stabilized 91.0

Note: SW30HRLE-4040 RO Element is a four inch diameter version of SW30HRLE-400 and may also be used as a pilot element to demonstrate performance for the design of larger systems. Permeate flow and salt rejection based on the following test conditions: 32,000 ppm NaCl feed stream (5ppm Boron, SW30HRLE), (25°C) and the pressure & recovery rates listed above. Permeate flows for individual elements may vary ±20%. For the purpose of improvement, specifications may be updated periodically.

6

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com


FILMTEC™ Membrane Elements Seawater RO Elements for Industrial Systems FILMTEC™ SW30HR-380 is a premium grade seawater reverse osmosis element featuring both high active area and high salt rejection to offer the best long-term economics for seawater desalination systems. FILMTEC SW30HRLE-400 delivers the highest boron rejection to help customers meet World Health Organization (WHO) and other drinking water standards. FILMTEC SW30-6040 elements deliver high performance over their operating lifetime without the use of oxidative post-treatments like many competitive products. This is one reason why FILMTEC elements are more durable and may be cleaned more effectively over a wide pH range than other RO elements. Operating Contditions Membrane Type Maximum Operating Temperature Maximum Operating Pressure Maximum Pressure Drop Feed water pH Range, Continuous Operation1 Feed water pH Range, Short-Term Cleaning (30 minutes) Maximum Feed water Silt Density Index (SDI) Free Chlorine Tolerance2

Polyamide Thin-Film Composite 45°C 1000 psig (69 bar), SW30HRLE: 1,200psig 15 psig (1 bar) 2-11 1-13 5 < 0.1 ppm

1: Maximum temperature for continuous operation above pH 10 is 35°C. 2: Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, FilmTec recommends removing residual free chlorine by pretreatment prior to membrane exposure.

Model No. SW30HR-380 SW30HRLE-400 SW30-6040

A inch 40 40 40

B mm 1016 1016 1016

inch 1.125 1.125 1.27

C mm 29 29 32.3

inch 7.9 7.9 5.97

mm 201 201 151.6

Filmtec supplies coupler part number 313198 with each element. Each coupler includes two 3-912 EPR o-rings (FilmTec part number 151705).

Ordering information Model No. SW30HR-380 SW30HRLE-400 SW30-6040

Permeate Flow Rate OD × L Active Surface Feed Spacer Applied lpd4 lph5 (inch) Area (Sq. Ft.) Thickness (mil) Pressure (psi) gpd3 6,000 23,000 960 8 x 40 380 28 800 7,500 28,000 1,160 8 x 40 400 28 800 2,100 8,000 330 8 x 40 N/A 34 800

Salt Rej (%) Stab. Min. 99.70 99.6 99.75 99.6 99.40 99.0

Boron Rej (%) Stabilized 92.0 91.0 N/A

Membrane

Dimension

The above values are normalized to the following test conditions: 32,000 ppm NaCl, 5 ppm Boron (SW30HR-380), 800 psi (5.5 MPa), (25°C), pH 8 and 8% recovery. Permeate flow rates for individual elements may vary ±15%. Sales specifications may vary as design revisions take place.

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

7


FILMTEC™ Membrane Elements iLECTM Seawater RO Elements for Industrial Systems A variety of FILMTEC seawater desalination elements are now available with iLEC interlocking end caps, an innovative element coupling technology that significantly enhances the performance of RO systems. Instead of using interconnectors to couple membranes endto-end within a vessel, interlocking end caps twist directly together, reducing the number of sealing surfaces to a single axially compressed O-ring. The design reduces the potential for seal leakage, enabling sustained higher quality permeate, and reduces energy-consuming flow resistance, resulting in lower operating cost. • • • • •

SW30 offers 34 mil feed spacer to lessen the impact of fouling SW30XLE offers high productivity and low energy requirements SW30ULE offers highest productivity available SW30HRLE offers high NaCl and boron rejection SW30HR highest boron rejection t

Operating Contditions Membrane Type Maximum Operating Temperature Maximum Operating Pressure Maximum Pressure Drop Feed water pH Range, Continuous Operation1 Feed water pH Range, Short-Term Cleaning (30 minutes) Maximum Feed water Silt Density Index (SDI) Free Chlorine Tolerance2

Polyamide Thin-Film Composite 45°C 1200 psig (83 bar) 15 psig (1 bar) 2-11 1-13 5 < 0.1 ppm

Membrane

1: Maximum temperature for continuous operation above pH 10 is 35°C. 2: Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, FilmTec recommends removing residual free chlorine by pretreatment prior to membrane exposure.

Dimension A

Model No. All models

inch 40

B mm 1,016

inch 40.5

C mm 1,029

inch 7.9

D mm 201

inch 1.125

Ordering information Model No. SW30XLE-400i SW30XLE-440i SW30ULE-400i SW30ULE-440i SW30HRLE-370/34i SW30HRLE-400i SW30HRLE-440i SW30XHR-400i

Permeate Flow Rate lpd4 gpd3 9,000 34,000 9,900 38,000 11,000 42,000 12,000 45,000 6,700 25,000 7,500 28,000 8,200 31,000 6,000 23,000

lph5 1,400 1,580 1,750 1,875 1,040 1,160 1,290 960

OD × L Active Surface Feed Spacer Applied (inch) Area (Sq. Ft.) Thickness (mil) Pressure (psi) 8 x 40 400 28 800 8 x 40 440 28 800 8 x 40 400 28 800 8 x 40 440 28 800 8 x 40 370 34 800 8 x 40 400 28 800 8 x 40 440 28 800 8 x 40 400 28 800

Salt Rej (%) Stab. Min. 99.80 99.65 99.80 99.65 99.70 99.60 99.70 99.60 99.80 99.65 99.80 99.65 99.80 99.65 99.82 99.70

The above benchmark values are based on the following test conditions: 32,000 ppm NaCl, 5 ppm Boron, 800 psi (5.5 MPa), 25°C, pH 8 and 8% recovery. Permeate flows for individual elements may vary ±15%. Product specifications may vary slightly as improvements are implemented.

8

mm 29

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Boron Rej (%) Stabilized 88 88 87 89 92 92 92 93


FILMTEC™ Membrane Elements Full Fit & Heat Sanitizable Membrane Elements FilmTec’s full-fit configuration minimizes stagnant areas and is an ideal choice for applications requiring a sanitary design. All components comply with U.S. Food & Drug Administration standards. • RO-390-FF product is a premier membrane for evaporator condensate polishing. • HSRO heat sanitizable reverse osmosis membrane elements deliver exceptional quality water with the added capability to withstand sanitization with hot water.

Operating Contditions Membrane Type Maximum Operating Temperature Maximum Sanitizing Temperature Maximum Operating Pressure Maximum Pressure Drop Feed water pH Range, Continuous Operation1

Thin-Film Composite 45°C 85°C 600 psig (41 bar) 15 psig (1 bar) RO: 3-10 HSRO: 2-11 1-12 5 < 0.1 ppm

Feed water pH Range, Short-Term Cleaning (30 minutes) Maximum Feed water Silt Density Index (SDI) Free Chlorine Tolerance2

1: Maximum temperature for continuous operation above pH 10 is 35°C. 2: Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, FilmTec recommends removing residual free chlorine by pretreatment prior to membrane exposure.

Model No. RO-4040-FF HSRO-4040-FF RO-390-FF HSRO-390-FF

A inch 40 40 40 40

B mm 1,016 1,016 1,016 1,016

inch 0.75 0.75 1.125 1.125

C mm 19 19 28.58 28.58

inch 3.9 3.9 7.9 7.9

mm 99 99 200 200

Active Surface Area (Sq. Ft.) 85 90 390 390

Applied Pressure (psi) 225 150 225 150

Stabilized Salt Rejection (%) 99.5 99.5 99.5 99.5

Ordering information Model No. RO-4040-FF HSRO-4040-FF RO-390-FF HSRO-390-FF

Permeate Flow Rate lpd4 gpd3 2,400 9,100 1,900 7,200 10,800 40,900 9,000 34,100

lph5 380 300 1,700 1,420

OD × L (inch) 4 x 40 4 x 40 8 x 40 8 x 40

Membrane

Dimension

Permeate flow and salt rejection based on the following test conditions: 2,000 ppm NaCl, pressure specified above, 25°C and 15% recovery. Elements must be conditioned prior to start-up. A one-time flux loss will occur during stabilization. Listed values apply after performance stabilization. Permeate flows for individual elements may vary ± 20%.

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

9


FILMTEC™ Membrane Elements Nanofiltration Membrane Elements FILMTEC™ NF270 membrane elements are ideal for removing a high percentage of TOC and THM precursors with medium to high salt passage and medium hardness passage. FILMTEC NF270 membrane is an ideal choice for surface water and ground water where good organic removal is desired with partial softening. FILMTEC™ NF90 membrane elements provide high productivity performance while removing a high percentage of salts, nitrate, iron and organic compounds such as pesticides, herbicides and THM precursors. The low net driving pressure of the NF90 membrane allows the removal of these compounds at low operating pressures.

Operating Contditions Membrane Type Maximum Operating Temperature Maximum Operating Pressure Maximum Pressure Drop Feed water pH Range, Continuous Operation

Polyamide Thin-Film Composite 45°C 600 psig (41 bar) 15 psig (1 bar) 2.5” & 4” Diameter : 2-11 8” Diameter : 3-10 2.5” & 4” Diameter : 1-12 8” Diameter : 1-13 2.5” Diameter : 13 psig (0.9 bar) 4” & 8” Diameter : 15 psig (1.0 bar)

Feed water pH Range, (Cleaning) Maximum Pressure Drop Maximum Feed Flow

2.5” Diameter : 6 gpm & 4” Diameter : 16 gpm 8” Diameter : 7 gpm 5 < 0.1 ppm

Membrane

Maximum Feed water Silt Density Index (SDI) Free Chlorine Tolerance2

Dimension A

Model No. NF270-2540, NF90-2540 NF270-4040, NF90-4040 NF270-400, NF90-400

inch 40 40 40

B mm 1,016 1,016 1,016

inch 1.19 1.05 1.5

C mm 30 27 38

inch 0.75 0.75 7.9

D mm 19 19 201

inch 2.4 3.9

mm 61 99

Ordering information Model No. NF270-2540 NF90-2540 NF270-4040 NF90-4040 NF270-400 NF90-400

gpd4 8501 6801 2,5001 2,0001 CaCl2: 14,7002 MgSO4: 12,5002 NaCl : 7,5003 MgSO4: 9,5003

Permeate Flow Rate lpd5 3,200 2,600 9,500 7,600 CaCl2: 55,6002 MgSO4: 47,3002 NaCl : 28,4003 MgSO4: 36,0003

lph6 130 108 395 315 CaCl2: 2,3152 MgSO4: 1,9702 NaCl : 1,1803 MgSO4: 1,5003

OD × L (inch) 2.5 x 40 2.5 x 40 4 x 40 4 x 40

Applied Pressure (psi) 70 70 70 70

8 x 40

70

8 x 40

70

1 Permeate flow and salt passage based on: 2000 mg/l MgSO4, 70 psi (0.48 MPa), and 25ºC and 15% recovery. 2 Permeate flow and salt passage based on: 500 mg/l CaCl2 or 2000 mg/l MgSO4, 70 psi (0.48 MPa), 25ºC, 15% recovery. 3 Permeate flow and salt passage based on: 2,000 mg/l NaCl or 2000 mg/l MgSO4, 70 psi (0.48 MPa), 25ºC, 15% recovery. 4 gpd: gallon per day, 5 lpd: liter per day, 6 lph: liter per hour

10

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Stabilized Salt Rejection (%) >97.01 >97.01 >97.01 >97.01 CaCl2: 40-602 MgSO4: > 972 NaCl : 85-953 MgSO4: >973


FILMTEC™ Membrane Elements Hollow Fiber Ultrafiltration Modules DOW™ Ultrafiltration module utilizes a double-walled hollow fiber (capillary) PVDF membrane which has a very small nominal pore diameter for PVDF material that allows for the removal of all particulate matter, bacteria and most viruses and colloids. Despite the small pore diameter, the membrane has a very high porosity resulting in a flux similar to that of micro-filtration (MF) and can effectively replace MF in most cases. Systems designed with DOW Ultrafiltration use an outside-in flow configuration which allows for less plugging, higher solids loading, higher flow area and easy cleaning. The primary flow design is deadend filtration but the module can be operated using a concentrate bleed. Dead-end filtration uses less energy and has a lower operating pressure than the concentrate bleed, therefore reducing operating costs. Dow Ultrafiltation advantages: • Low fouling Hydrophilic Polyvinylidenefluoride (H-PVDF) membrane • Excellent filtration performance with high flux • Durable and break resistant double- walled fiber structure • High chemical resistance and temperature tolerance for effective membrane cleaning • Very fine nominal pore diameter (0.03 μm) • High removal efficiency of bacteria and viruses • Dead-end or concentrate bleed flow capabilities • Outside-In flow configuration that allows for less plugging and higher solids loading, • higher flow area and easier cleaning • Can be periodically back washed and air scoured to improve performance and extend operating life by removing the • fouling layer • Simple, vertical, modular design allows low cost, compact systems

24 – 70 gfd (40 – 120 l/m²/hr) 2-11 34 – 104°F (1 – 40°C) 93.75 psi (6.25 bar) 30 psi (2.1 bar) 7.1 scfm (12 Nm³/hr) 36 psi (2.5 bar)

NaOCl (max) TSS (max) Turbidity (max) Particle Size (max) Flow Configuration Expected Filtrate Turbidity Expected Filtrate SDI

2,000 mg/l 100 mg/l 300 ntu 300 μm Outside In, Dead End Flow ≤ 0.1 NTU ≤ 2.5

Ordering information Permeate Flow Rate Size Model No. (inch) gpd lph Pretreatment Models SFP-2660 6 x 60 5.9–17.3 1,300-4,000 SFP-2860 8 x 60 9.2–26.7 2,000-6,100 SFP-2880 8 x 80 3.1–9.3 13,600-40,900 NSF/ANSI 61 Drinking Water Models SFD-2660 6 x 60 5.9-17.3 1,300-4,000 SFD-2860 8 x 60 9.2-26.7 2,000-6,100 SFD-2880 8 x 80 3.1-9.3 13,600-40,900

Membrane Area m2 Ft2

sales@acropore.com

Module Volume gallon Liter

Weight-EMPTY lbs kg

Weight-Water lbs kg

355 549 829

33 51 77

4.2 9.3 10.3

16 35 39

25 106 135

55 48 61

41 183 220

90 83 100

355 549 829

33 51 77

4.2 9.3 10.3

16 35 39

25 106 135

55 48 61

41 183 220

90 83 100

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Membrane

Operating Contditions Filtrate Flux @ 25°C pH, Operating Temperature Max. Inlet Module Pressure (@20°C) Max. Operating TMP Max. Operating Air Scour Flow Max. Backwash Pressure

11


Hydranautics Membrane Elements ESPA® Ultra Low Pressure Membrane Elements When high productivity from a membrane element is important, the ESPA family of products is the right choice. ESPA (Energy Saving Polyamide) membranes achieve high flux without compromising on the standard for high rejection. The ESPA membranes find wide applications in the industry due to the significant cost savings associated with their use.

• • • • • •

High Permeate Flow Lower operating pressure Lower energy consumption High Salt Rejection Lowest Biological And Colloidal Fouling Higher rejection for impurities including Silica and Boron Greater tolerance to high pH cleanings

ESPA SERIES – Ultra Low Pressure Brackish Water RO Membranes ESPA1 – High Productivity, energy saving membranes ESPA2-LD – New technology for higher productivity; minimizes biofouling & colloidal fouling; enhanced cleanability ESPA2 MAX – Highest productivity at the highest rejection level ESPA4-LD & ESPA4 MAX– Extra Low energy membranes with high productivity & rejection

Membrane

ESPABMAX – Boron Removal, provides a new option for communities by boron contamination issues. Applications • Municipal Potable and Wastewater Plants • Bottling Operations • Light Industrial

Operating Contditions Configuration: Membrane Polymer: Maximum Chlorine Concentration: Maximum Operating Temperature: Maximum Feedwater SDI (15 mins):

Spiral wound Composite Polyamide < 0.1 ppm 45 OC 2.5” Dia. & 4” 14 & 21”L: 4.0 4×40” & 8”×40”: 5.0 1.0 NTU 3-10 5:1 10 psi 2.5” Dia. & 4” 14 & 21”L: 300 psi 4×40” & 8”×40”: 600 psi

Maximum Feedwater Turbidity Feedwater pH Range: Maximum Single-Element Recovery Ratio: Maximum Single-Element Pressure Drop: Maximum Applied Pressure:

Note: Performance specifications based on 1,500 ppm NaCl solution (ESPA4 500 pm NaCl), 25°C temperature, feed water pH 6.5-7, 15% recovery and applied pressures as listed above. Element permeate +35% or -15%. See technical literature for extended pH tolerance and additional application data.

Ordering information Model No. ESPA-2514 ESPA-2521 ESPA-2540 ESPA-4014 ESPA-4021 ESPA1-4040 ESPA2-LD-4040 ESPA4-4040 ESPA1 ESPA2-LD ESPA2MAX ESPA4-LD ESPA4MAX

Dia × L (inch) 2.5 × 14 2.5 × 21 2.5 × 40 4 × 14 4 × 21 4 × 40 4 × 40 4 × 40 8 × 40 8 × 40 8 × 40 8 × 40 8 × 40

gpd3 250 350 750 500 1,000 2,600 2,000 2,500 12,000 10,000 12,000 12,000 13,200

Permeate Flow Rate lpd4 900 1,300 2,800 1,900 3,800 9,800 7,600 9,500 45,400 37,900 45,400 45,400 50,000

lph5 37 54 116 79 158 408 316 395 1891 1579 1891 1891 2083

Tested Pressure (psi) 150 150 150 150 150 150 150 100 150 150 150 100 100

3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

12

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Nominal Salt Rejection (%) 99.4 99.4 99.4 99.4 99.4 99.3 99.6 99.2 99.3 99.6 99.6 99.2 99.2

Minimum Salt Rejection (%) 98.0 98.0 98.0 98.0 98.0 99.0 99.4 99.0 99.0 99.5 99.5 99.0 99.0


Hydranautics Membrane Elements CPA High Rejection Membrane Elements CPA (Composite Polyamide) elements set the standard for RO membrane elements – over 600 million gallons per day of pure water are produced by CPA elements for global municipalities and industries.

• • • • • •

High Permeate Flow Lower operating pressure Lower energy consumption High Salt Rejection Lowest Biological And Colloidal Fouling Higher rejection for impurities including Silica and Boron Greater tolerance to high pH cleanings

CPA2 – “The Workhorse” Most widely used with consistent performance CPA3 – Best combination of productivity and salt rejection available CPA5-LD Series – New technology minimizing bio-fouling and colloidal fouling and enhancing cleanability Applications • Desalting of well waters – municipal drinking water • Reducing TDS prior to ion exchange • Boiler make-up water • Ultrapure water for semi-conductor manufacture

Operating Contditions Configuration: Membrane Polymer: Maximum Chlorine Concentration: Maximum Operating Temperature: Maximum Feedwater SDI (15 mins): Maximum Feedwater Turbidity Feedwater pH Range: Maximum Single-Element Recovery Ratio: Maximum Single-Element Pressure Drop: Maximum Applied Pressure:

Spiral wound Composite Polyamide < 0.1 ppm 45 OC 5 1.0 NTU 3-10 5:1 10 psi 600 psi

Dimension A

Model No. CPA2-4040, CPA5-LD-4040 CPA3, CPA5-LD, CPA5 MAX

inch 40 40

B mm 1016 1016

inch 3.95 7.89

C mm 100.3 200

inch 0.75 1.125

mm 19.1 28.6

Membrane

Note: Performance specifications based on 1,500 ppm NaCl solution (ESPA4 500 pm NaCl), 25°C temperature, feed water pH 6.5-7, 15% recovery and applied pressures as listed above. Element permeate +35% or -15%. See technical literature for extended pH tolerance and additional application data.

Ordering information Model No. CPA2-4040 CPA5-LD-4040 CPA3 CPA5-LD CPA5MAX

Dia × L (inch) 4 × 40 4 × 40 8 × 40 8 × 40 8 × 40

gpd3 2,250 2,100 11,000 11,000 12,000

Permeate Flow Rate lpd4 8,500 7,950 41,600 41,600 45,400

lph5 355 330 1,733 1,733 1,890

Tested Pressure (psi) 225 225 225 225 225

Nominal Salt Rejection (%) 99.5 99.7 99.7 99.7 99.7

Minimum Salt Rejection (%) 99.2 99.5 99.6 99.6 99.6

3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

13


Hydranautics Membrane Elements LFC® Low Fouling Membrane Elements LFC® (Low Fouling Composite) elements combine neutral surface charge and hydrophilicity, providing significant reduction in fouling rates and increasing membrane efficiency by restoring nominal performance after cleaning. The LFC3-LD is designed with a thicker brine spacer lowering the Delta P meeting the increased demand for lower fouling membranes that require less frequent cleanings while maintaining a high permeate flow. The LFC3-LD provides 11,000 gallons per day (41.6 m3/d) of flow at 99.7% nominal salt rejection. This membrane is well suited for the treatment of difficult feed waters for numerous municipal and industrial applications, which up to now required significant feed water pretreatment upstream of any composite reverse osmosis membrane. • high permeate flow • high salt rejection • Lower colloidal fouling • Reduced biofouling • Increased membrane durability • Lower dP (differential pressure) • Greater tolerance to high pH cleanings • Improved flux distribution

Membrane

Applications: • Municipal wastewater treatment • Industrial wastewater treatment • Wastewater with high biological and organic fouling potential Operating Contditions Configuration: Membrane Polymer: Maximum Chlorine Concentration: Maximum Operating Temperature: Maximum Feedwater SDI (15 mins): Maximum Feedwater Turbidity Feedwater pH Range: Maximum Single-Element Recovery Ratio: Maximum Single-Element Pressure Drop: Maximum Applied Pressure:

Spiral wound Composite Polyamide < 0.1 ppm 45 OC 5 1.0 NTU 3-10 5:1 10 psi 600 psi

Note: Performance specifications based on 1,500 ppm NaCl solution (ESPA4 500 pm NaCl), 25°C temperature, feed water pH 6.5-7, 15% recovery and applied pressures as listed above. Element permeate +35% or -15%. See technical literature for extended pH tolerance and additional application data.

Dimension A

Model No. LFC3-LD-4040 LFC3-LD

inch 40 40

B mm 1016 1016

inch 3.95 7.89

C mm 100.3 200

inch 0.75 1.125

mm 19.1 28.6

Ordering information Model No. LFC3-LD-4040 LFC3-LD

Dia × L (inch) 4 × 40 8 × 40

gpd3 2,100 11,000

Permeate Flow Rate lpd4 7,950 41,600

lph5 330 1,733

Tested Pressure (psi) 225 225

3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

14

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Nominal Salt Rejection (%) 99.7 99.7

Minimum Salt Rejection (%) 99.5 99.5


Hydranautics Membrane Elements SWC® Seawater Membrane Elements SWC seawater desalination elements offer the highest levels of salt rejection and a consistently pure end product. Membrane formulations are designed to accommodate varying levels of seawater salinities worldwide with reliable field-proven performance. SWC4B MAX – Highest Boron Rejection Available (95% average) SWC5 MAX, SWC5-LD – Lower Fouling for Maximum Performance SWC6-4040, SWC6, SWC6 MAX – Highest Permeate Flow Rate Available with 91% Average Boron Rejection Applications: • Boiler makeup water in power industry • Conventional and hybrid desalination plants • Boron reduction for agricultural application

Operating Contditions Configuration: Membrane Polymer: Maximum Chlorine Concentration: Maximum Operating Temperature: Maximum Feedwater SDI (15 mins):

Spiral wound Composite Polyamide < 0.1 ppm 45 OC 2.5” Dia. & 4” 14 & 21”L: 4.0 4×40” & 8”×40”: 5.0 1.0 NTU 2.5” Dia. & 4” 14 & 21”L: 3-10 4×40” & 8”×40”: 2-11 5:1 10 psi 2.5” Dia. & 4” 14 & 21”L: 1,000 psi 4×40” & 8”×40”: 1,800 psi

Maximum Feedwater Turbidity Feedwater pH Range: Maximum Single-Element Recovery Ratio: Maximum Single-Element Pressure Drop: Maximum Applied Pressure:

Note: Performance specifications based on 1,500 ppm NaCl solution (ESPA4 500 pm NaCl), 25°C temperature, feed water pH 6.5-7, 15% recovery and applied pressures as listed above. Element permeate +35% or -15%. See technical literature for extended pH tolerance and additional application data.

A

Model No. SWC-2514 SWC-2521 SWC-2540 SWC-4014 SWC-4021 SWC – All 4”×40” SWC – All 8”×40”

inch 14 21 40 14 21 40 40

B mm 355.6 533.4 1,016 355.6 533.4 1,016 1,016

inch 2.4 2.4 2.4 3.95 3.95 3.95 7.89

C mm 61 61 61 100.3 100.3 100.3 200

inch 0.75 0.75 0.75 0.75 0.75 0.75 1.125

mm 19.1 19.1 19.1 19.1 19.1 19.1 28.6

Maximum Feed Flow gpm lph 6 1,400 6 1,400 6 1,400 12 2,700 12 2,700 16 3,600 75 17,000

Membrane

Dimension

Ordering information Model No. SWC-2514 SWC-2521 SWC-2540 SWC-4014 SWC-4021 SWC5-LD-4040 SWC6-4040 SWC4BMAX SWC5-LD SWC5MAX SWC6 SWC6MAX

Dia × L (inch) 2.5 × 14 2.5 × 21 2.5 × 40 4 × 14 4 × 21 4 × 40 4 × 40 8 × 40 8 × 40 8 × 40 8 × 40 8 × 40

gpd3 110 220 520 370 640 1,750 2,500 7,200 9,000 9,900 12,000 13,200

Permeate Flow Rate lpd4 400 800 2,000 1,400 2,400 6,600 7,200 27,300 34,100 37,500 45,500 50,000

lph5 16 32 83 58 100 275 300 1,137 1,420 1,562 1,895 2,083

Tested Pressure (psi) 800 800 800 800 800 800 800 800 800 800 800 800

Nominal Salt Rejection (%) 99.4 99.4 99.4 99.4 99.4 99.7 99.7 99.8 99.8 99.8 99.8 99.8

Minimum Salt Rejection (%) 99.0 99.0 99.0 99.0 99.0 99.5 99.5 99.7 99.7 99.7 99.7 99.7

3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

15


Hydranautics Membrane Elements Nanofiltration Membrane Elements ESNA SERIES – Energy Saving Nanofiltration (NF) Membranes High performance energy savings ESNA nanofiltration membrane elements are ideal for softening applications and the removal of pesticides, bacteria or viruses. They provide 50%-90% salt rejection with ultra-low-pressure operations, increased energy savings, and significantly lower installation and operating costs. They can effectively remove organics which can form disinfection by-products in municipal water distribution lines. At the Boca Raton plant the THM formation potential was reduced from 0.6 mg/L to less than 0.020 mg/L, well below the 0.042 mg/L limit. Applications • Up to 91% nominal rejection • Effectively removes organics • Optimum hardness rejection • Ultra-low pressure, energy saving, lower OPEX.

Operating Contditions Configuration: Membrane Polymer: Maximum Chlorine Concentration: Maximum Operating Temperature: Maximum Feedwater SDI (15 mins):

Spiral wound Composite Polyamide < 0.1 ppm 45 OC LF-LD : 5.0 LF2-LD: 4.0 1.0 NTU 2-10 5:1 10 psi 600 psi

Maximum Feedwater Turbidity Feedwater pH Range: Maximum Single-Element Recovery Ratio: Maximum Single-Element Pressure Drop: Maximum Applied Pressure:

Membrane

Note: Performance specifications based on 1,500 ppm NaCl solution (ESPA4 500 pm NaCl), 25°C temperature, feed water pH 6.5-7, 15% recovery and applied pressures as listed above. Element permeate +35% or -15%. See technical literature for extended pH tolerance and additional application data.

Dimension A

Model No. ESNA1-LF-LD-4040 & ESNA1-LF2-LD-4040 ESNA1-LF-LD & ESNA1-LF2-LD

B

C

Maximum Feed Flow gpm lph

inch

mm

inch

mm

inch

mm

40

1,016

3.95

100.3

0.75

19.1

16

3.6

40

1,016

7.89

200

1.125

28.6

75

17

Ordering information Model No. ESNA1-LF-LD-4040 ESNA1-LF2-LD-4040 ESNA1-LF-LD ESNA1-LF2-LD

Dia × L (inch) 4 × 40 4 × 40 8 × 40 8 × 40

gpd3 1,700 2,000 8,200 10,500

Permeate Flow Rate lpd4 6,400 7,600 31,000 39,700

lph5 266 316 1291 1654

Tested Pressure (psi) 75 75 75 75

3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

16

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Nominal Salt Rejection (%) 89 86 89 86

Minimum Salt Rejection (%) 86 83 86 83


Hydranautics Membrane Elements HYDRAcap® Ultrafiltration Modules HYDRAcap is used to treat surface water, ground water, seawater and waste water as either primary treatment or as pre-treatment to reverse osmosis (RO) and Nano filtration (NF). Compared to conventional pretreatment, HYDRAcap allows higher fluxes for RO and NF systems while maintaining longer intervals between cleanings. In some cases it replaces conventional pretreatment for portable applications, ground water recharging and water recycling. HYDRAcap® Advantages and Peformance • Low fouling hydrophilic polyethersulfone membrane • Tolerant to chlorine, peroxide and other oxidants. • Resistant to pH extremes • Filtrate Turbidity: ≤ 0.07 NTU • Virus & Bacteria Removal: ≥ 4 log • TOC Reduction: 5 – 65% • MWCO, nominal: 150,000 Daltons • Operating Mode: Inside to Outside Filtration; Direct flow or Crossflow.

Operating Contditions Configuration: Membrane Polymer: Nominal MWCO, daltons Typical Filter Flux Range, GFD (l/m2/hr) Operating pH Range Claning pH Range Instantaneous Chlorine Tolerance, ppm Operating Mode Maximum operating Temperature Maximum Feed Pressure: Maximum Turbidity

Capillary (inside-out) Hydrophillic polyethersulfone 150,000 30-75 (51-128) 4-10 2-13 100 Cross-Flow or Dead-end, Backflushable 40 OC 73 psi (5 bar) 100 NTU

Model No. HYDRAcap40, 40-LD HYDRAcap80, 60-LD

A inch 40 63

B mm 1092 1600

inch 46.125 66.125

C mm 1172 1680

inch 47.25 67.25

mm 1200 1708

Pipe Connections 2” Victaulic 2” Victaulic

Ave. Weight lbs 63 97

kg 28 44

Membrane

Dimension

Ordering information Model No. HYDRAcap40 HYDRAcap40-LD HYDRAcap60 HYDRAcap60-LD

Permeate Flow Rate gpm1 lph2 7–19 1,600–4,400 5–12.3 1,100–2,800 11–30 2,700–6,800 7.8–19 1,800–4,300

Nomonal Membrane Area (ft2) 320 208 500 323

Numer of Fibers 13,200 5,600 13,200 5,600

Fiber Dimensions ID OD 0.031” (0.8 mm) 0.051” (1.3 mm) 0.047” (1.2 mm) 0.080” (2.0 mm) 0.031” (0.8 mm) 0.051” (1.3 mm) 0.047” (1.2 mm) 0.080” (2.0 mm)

1 gpm: gallon per minuit, 2 lph: liter per hour

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

17


KOCH Membrane Elements HR Series - High Rejection Low Pressure Thin Film Elements • Membrane Chemistry: Proprietary TFC® polyamide • Membrane Type: TFC® HR membrane for High rejection • Membrane Type: TFC® FR membrane for High rejection with Fouling resistance • Construction: Spiral wound with fiberglass outerwrap • Applications: Municipal Water Solutions Municipal Wastewater Water Reuse Process Water Food & Beverage Wastewater Treatment Metal Finishing Water Reuse Power Solutions Mining Water Solutions Semiconductor Solutions Bottled Water Water Recovery

Operating Contditions Typical Operating Pressure: Maximum Operating Pressure: Maximum Operating Temperature: Maximum Cleaning Temperature: Maximum Continuous Free Chlorine: Allowable pH Maximum Differential Pressure

Membrane

Maximum Feed Turbidity: Maximum Feed SDI (15 min test):

150-250 psi (1,035-1,725 kPa) 600 psi (4,140 kPa) 113°F (45°C) 113°F (45°C) < 0.1 mg/l Continuous Operation: 4 - 11 Short Term Cleaning: 2.5 - 11 per 40” Long Element: 10 psi (69 kPa) per Vessel: 60 psi (414 kPa) 1 NTU 5

Dimension Model No. 4040-HR 4040-HR-T 4040-FR 8040-HR-375 8040-HR-400 8040-FR-375 8040-FR-400

A inch 40 40 40 40 40 40 40

B mm 1016 1016 1016 1016 1016 1016 1016

inch 4.0 4.0 4.0 8.0 8.0 8.0 8.0

C mm 101.6 101.6 101.6 203 203 203 203

inch 0.75 0.75 0.75 1.125 1.125 1.125 1.125

D mm 19.0 19.0 19.0 29 29 29 29

inch 1.0 1.0 1.0

mm 25.4 25.4 25.4

Weight lbs kg 10 4.5 10 4.5 10 4.5 44 20 44 20 44 20 44 20

Connector 0035267 0035267 0035267 0035260 0035260 0035260 0035260

Part numbers O-ring 0035458 0035458 0035458 0035464 0035464 0035464 0035464

Brine Seal 0035702 0035702 0035702 0030584 0030584 0030584 0030584

Ordering information Model No. 4040-HR 4040-HR-T 4040-FR 8040-HR-375 8040-HR-400 8040-FR-375 8040-FR-400

Dia × L (inch) 4 × 40 4 × 40 4 × 40 8 × 40 8 × 40 8 × 40 8 × 40

Permeate Flow Rate Chloride Tested gpd3 lpd4 lph5 Rejection (%) Pressure (psi) 2,270 8,600 358 99.55 225 2,270 8,600 358 99.55 225 2,270 8,600 358 99.55 225 10,200 38,600 1,608 99.5 225 11,000 41,600 1,733 99.5 225 10,200 38,600 1,608 99.5 225 11,000 41,600 1,733 99.5 225

Overwrap Fiberglass Tape Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass

Membrane Area (ft2) (m2) 85 7.9 85 7.9 85 7.9 375 34.8 400 37.2 375 34.8 400 37.2

Test Conditions: 2,000 mg/l NaCl (700mg/l for 2.5”) solution at 225 psi (1,550 kPa) applied pressure, 15% recovery, 77°F (25°C) and pH 7.5 3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

18

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Feed Spacer mil mm 28 0.7 28 0.7 28 0.7 31 0.8 28 0.7 31 0.8 28 0.7


KOCH Membrane Elements XR Series – Extra High Rejection Thin Film Elements • • • •

Membrane Chemistry: Proprietary TFC® polyamide Membrane Type: TFC® XR membrane Construction: Spiral wound with fiberglass outerwrap Regulatory Information: Certified by NSF to NSF/ANSI Standard #61 Drinking Water • System Components - Health Effects • Applications: Municipal Water Solutions Municipal Wastewater Water Reuse Process Water Food & Beverage Wastewater Treatment Metal Finishing Water Reuse Power Solutions Mining Water Solutions Semiconductor Solutions Bottled Water Water Recovery

Operating Contditions Typical Operating Pressure: Maximum Operating Pressure: Maximum Operating Temperature: Maximum Cleaning Temperature: Maximum Continuous Free Chlorine: Allowable pH Maximum Differential Pressure Maximum Feed Turbidity: Maximum Feed SDI (15 min test):

225-450 psi (1,550-1,725 kPa) 600 psi (4,140 kPa) 113°F (45°C) 113°F (45°C) < 0.1 mg/l Continuous Operation: 4 - 11 Short Term Cleaning: 2.5 - 11 per 40” Long Element: 10 psi (69 kPa) per Vessel: 60 psi (414 kPa) 1 NTU 5

Model No. 4040-XR 8040-XR-375 8040-XR-400

A inch 40 40 40

B mm 1016 1016 1016

inch 4.0 8.0 8.0

C mm inch 101.6 0.75 203 1.125 203 1.125

D mm 19.0 29 29

inch 1.0

mm 25.4

Weight lbs kg 10 4.5 38 17 38 17

Connector 0035267 0035260 0035260

Part numbers O-ring 0035458 0035458 0035458

Brine Seal 0035702 0035702 0035702

Membrane

Dimension

Ordering information Model No. 4040-XR 8040-XR-375 8040-XR-400

Dia × L (inch) 4 × 40 8 × 40 8 × 40

Permeate Flow Rate Chloride Tested Overwrap gpd3 lpd4 lph5 Rejection (%) Pressure (psi) 2,200 8,300 345 99.75 325 Fiberglass 9,800 37,100 1,545 99.75 325 Fiberglass 10,500 39,700 1,733 99.5 325 Fiberglass

Membrane Area (ft2) (m2) 85 7.9 375 34.8 400 37.2

Feed Spacer mil mm 28 0.7 31 0.8 28 0.7

Test Conditions: 2,000 mg/l NaCl (700mg/l for 2.5”) solution at 225 psi (1,550 kPa) applied pressure, 15% recovery, 77°F (25°C) and pH 7.5 3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

19


KOCH Membrane Elements HRX Series - Food & Dairy Sanitary RO Elements • • • •

Membrane Chemistry: Proprietary TFC® polyamide Membrane Type: High rejection reverse osmosis Construction: Sanitary spiral wound with net outerwrap Regulatory Status: Compliant with US FDA CFR Title 21, EC Reg. No. 1935/2004, and EU Reg. No. 10/2011. Halal-certified by the Islamic Food and Nutrition Council of America (IFANCA) • Applications: Protein Processing Nutraceuticals Food & Feed Milk Whey Brine Bottled Water Industrial Biotechnology Pharmaceutical Intermediates Operating Contditions SpiraPro 4” 300-600 psi (20.7-41.4 bar) 650 psi (44.8 bar) 122 °F (50°C) 122°F (50°C) Continuous Operation: 4 - 10 Cleaning-In-Place(CIP): 1.8 - 11 per Element: 6-10 psi (0.4-0.7 bar) per Vessel: 30-50 psi (2.1-3.4 bar)

Typical Operating Pressure: Maximum Operating Pressure: Maximum Operating Temperature: Maximum Cleaning Temperature: Allowable pH Maximum Differential Pressure

SpiraPro 8” 200-450 psi (13.8-31.0 bar) 650 psi (44.8 bar) 122 °F (50°C) 113°F (45°C) Continuous Operation: 4 - 10 Cleaning-In-Place(CIP): 1.8 - 11 per Element: 3-6 psi (0.2-0.4 bar) per Vessel: 15-35 psi (1.0-2.4 bar) HRX 8040

Membrane

HRX 3838”

Dimension Model No. 3838 HRX 3839 HRX 7838 HRX 8038 HRX 8040 HRX

A inch 38.0 38.8 38.0 38.0 40.0

B mm 965 984 1016 1016 1,016

inch 3.8 3.8 7.7 7.9 7.9

C mm 96 96 197 201 201

inch 0.831 0.831 1,125 1,125 1,125

mm 21.1 21.1 28.6 28.6 28.6

Ordering information Model No. 3838 HRX-NYV 3839 HRX-NYV 3838 HRX-VYV 3839 HRX-VYV 7838 HRX-NYV 8038 HRX-NYV 8038 HRX-NYT 8038 HRX-VYV 8040 HRX-NYVP

20

Dia × L (inch) 3.8 x 38.0 3.8 x 39.0 3.8 x 38.0 3.8 x 39.0 7.8 x 38.0 7.9 x 38.0 7.9 x 38.0 7.9 x 38.0 7.9 x 40.0

Minimum Rejection (%) 99.5 99.5 99.5 99.5 99.5 99.5 99.5 99.5 99.5

sales@acropore.com

Active Membrane Area (ft2) (m2) 76 7.1 76 7.1 61 5.7 61 5.7 350 32.5 371 34.5 371 34.5 291 27.0 371 34.5

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Feed Spacer mil 31 31 46 46 31 31 31 46 31

mm 0.8 0.8 1.1 1.1 0.8 0.8 0.8 1.1 0.8


KOCH Membrane Elements SW Series – Seawater Elements • • • • •

Membrane Chemistry: Proprietary TFC® polyamide Membrane Type: TFC® SW membrane Membrane Type: TFC® HF membrane for High flow Construction: Spiral wound with fiberglass outerwrap Applications: Seawater desalination

Operating Contditions Typical Operating Pressure: Maximum Operating Pressure: Maximum Operating Temperature: Maximum Cleaning Temperature: Maximum Continuous Free Chlorine: Allowable pH Maximum Differential Pressure Maximum Feed Turbidity: Maximum Feed SDI (15 min test):

750-950 psi (5,175-6,555 kPa) 1,200 psi (8,275 kPa) 113°F (45°C) 113°F (45°C) < 0.1 mg/l Continuous Operation: 4 - 11 Short Term Cleaning: 2.5 - 11 per Element: 10 psi (69 kPa) per Vessel: 60 psi (414 kPa) 1 NTU 5

Model No. 4040-SW 4040-HF 8040-SW-335 8040-SW-400 8040-HF-400

A inch 40 40 40 40 40

B mm 1016 1016 1016 1016 1016

inch 4.0 4.0 8.0 8.0 8.0

C mm inch 101.6 0.75 101.6 0.75 203 1.125 203 1.125 203 1.125

D mm 19.0 19.0 29 29 29

inch 1.0 1.0

mm 25.4 25.4

Weight lbs kg 10 4.5 10 4.5 38 17 38 17 38 17

Connector 0035267 0035267 0035260 0035260 0035260

Part numbers O-ring 0035458 0035458 0035458 0035458 0035458

Brine Seal 0035702 0035702 0035702 0035702 0035702

Ordering information Model No. 4040-SW 4040-HF 8040-SW-335 8040-SW-400 8040-HF-400

Dia × L (inch) 4 × 40 4 × 40 8 × 40 8 × 40 8 × 40

Permeate Flow Rate Chloride Tested gpd3 lpd4 lph5 Rejection (%) Pressure (psi) 1,330 5,000 208 99.75 800 1,760 6,600 275 99.75 800 6,000 22,700 945 99.75 800 7,200 27,200 1,133 99.75 800 9,500 36,000 1,500 99.75 800

Overwrap Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass

Membrane Area (ft2) (m2) 74 6.9 74 6.9 375 34.8 400 37.2 400 37.2

Feed Spacer mil mm 31 0.8 31 0.8 31 0.8 28 0.7 28 0.7

Membrane

Dimension

Test Conditions: 32,800 mg/l NaCl solution (isosmotic to ASTM standard seawater) at 800 psi (5,520 kPa) applied pressure, 7% recovery, 77°F (25°C) and pH 7.5 3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

21


KOCH Membrane Elements SelRO® MPS Series - pH Stable Nanofiltration Membrane • Membrane Chemistry: Proprietary composite nanofiltration membrane • Membrane Type: pH stable nanofiltration membrane • Construction: Spiral wound element • Major Applications: Acid and caustic recovery, Product concentration • Permeate Tube Material: CPVC • Applications: Nutraceuticals Chemical Recovery Industrial Biotechnology Solutions Pharmaceutical Intermediates Solutions General Industrial Solutions Operating Contditions Typical Operating Pressure: Maximum Operating Temperature: Molecular weight Cutoff (MWCO)

220-510 psi (15-35 bar) 122°F (50°C) MPS-34 : 200 Dalton MPS-36 : 1,000 Dalton Continuous Operation: 0 - 14 Short Term Cleaning: 0 - 14 per Element: 10 psi (0.7 bar) per Vessel: 50 psi (3.5 bar)

Allowable pH

Membrane

Maximum Differential Pressure

Dimension A

Model No. MPS-34-2540 MPS-34-4040 MPS-34-8040-B2X MPS-34-8040-B2Z MPS-34-8040-C2Z MPS-36-2540 MPS-36-4040 MPS-36-8040-B2X MPS-36-8040-B2Z

inch 40 40 40 40 40 40 40 40 40

B mm 1016 1016 1016 1016 1016 1016 1016 1016 1016

inch 2.4 3.9 7.9 7.9 7.9 2.4 3.9 7.9 7.9

C mm 61 99 200 200 200 61 99 200 200

inch 0.75 0.75 1.187 1.187 1.187 0.75 0.75 1.187 1.187

D mm 19.0 19.0 30.15 30.15 30.15 19.0 19.0 30.15 30.15

inch 1.0 1.0

mm 25.4 25.4

1.0 1.0

25.4 25.4

Ordering information Model No. MPS-34-2540-A2X MPS-34-2540-A2Z MPS-34-4040-A2X MPS-34-4040-A2Z MPS-34-8040-B2X MPS-34-8040-B2Z MPS-34-8040-C2Z MPS-36-2540-A2X MPS-36-4040-A2X MPS-36-8040-B2X MPS-36-8040-B2Z

Rejection (%) Dia × L (inch) Glucrose Sucrose 2.5 x 40 95 97 2.5 x 40 95 97 4 x 40 95 97 4 x 40 95 97 8 x 40 95 97 8 x 40 95 97 8 x 40 95 97 2.5 x 40 30 50 2.5 x 40 30 50 8 x 40 30 50 8 x 40 30 50

NaCl 35 35 35 35 35 35 35 10 10 10 10

Permeate Flow Rate gpd3 lpd4 lph5 610 2,300 95 455 1,700 70 2,240 8,500 354 1,520 5,800 241 10,250 39,000 1,625 10,250 39,000 1,625 7,250 27,400 302 2,536 9,600 400 9,350 35,400 1,475 34,500 130,000 5,416 24,000 91,000 3,791

Overwrap Tape Tape Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Tape Fiberglass Fiberglass Fiberglass

Membrane Area (ft2) (m2) 17.2 1.6 12.9 1.2 60.3 5.6 43.0 4.0 290 27 205 19 290 27 17.2 1.6 60.3 5.6 290 27 205 19

*Test Conditions: RO water at 440 psi (30 bar), 86°F (30°C). Feed solution for rejection tests is 3% glucose / 3% sucrose or 5% NaCl. 3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

22

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Feed Spacer mil mm 30 0.8 57 1.4 30 0.8 57 1.4 30 0.8 57 1.4 30 0.8 30 0.8 30 0.8 30 0.8 57 1.4


KOCH Membrane Elements SPIRAPRO Series – Pharmaceutical Grade NF Elements • • • • •

Membrane Chemistry: Proprietary TFC® polyamide Membrane Type: Selective rejection nanofiltration Observed molecular weight cut-off: 200 daltons Construction: Sanitary spiral wound with net outerwrap Regulatory Status: USP Class VI testing for element components. Conform to FDA food-contact regulations (CFR Title 21). • Applications: Desalting Concentration and separation of antibiotics and API’s

Operating Contditions SpiraPro 4” 200-450 psi (13.8-31.0 bar) 650 psi (44.8 bar) 122 °F (50°C) 122°F (50°C) Continuous Operation: 3 - 10 Cleaning-In-Place(CIP): 1.8 - 11 per Element: 6-10 psi (0.4-0.7 bar) per Vessel: 30-50 psi (2.1-3.4 bar)

Typical Operating Pressure: Maximum Operating Pressure: Maximum Operating Temperature: Maximum Cleaning Temperature: Allowable pH Maximum Differential Pressure

SpiraPro 8” 200-450 psi (13.8-31.0 bar) 650 psi (44.8 bar) 122 °F (50°C) 113°F (45°C) Continuous Operation: 4 - 10 Cleaning-In-Place(CIP): 1.8 - 11 per Element: 3-6 psi (0.2-0.4 bar) per Vessel: 15-35 psi (1.0-2.4 bar)

SpiraPro 8040

SpiraPro 3838”

Model No. SPIRAPRO 3838 SR3-NYV SPIRAPRO 3838 SR3-VYV SPIRAPRO 8040 SR3-NYVP SPIRAPRO 8040 SR3-VYVP

A inch 38.0 38.0 40.0 40.0

B mm 965 965 1016 1016

inch 3.8 3.8 7.9 7.9

C mm 96 96 201 201

inch 0.831 0.831 1,125 1,125

mm 21.1 21.1 28.6 28.6

Membrane

Dimension

Ordering information Model No. SPIRAPRO 3838 SR3-NYV SPIRAPRO 3838 SR3-VYV SPIRAPRO 8040 SR3-NYVP SPIRAPRO 8040 SR3-VYVP

Dia × L (inch) 3.8 x 38.0 3.8 x 38.0 7.9 x 40.0 7.9 x 40.0

Minimum Rejection (%) 99.0 99.0 99.0 99.0

Active Membrane Area (ft2) (m2) 76 7.1 61 5.7 371 34.5 291 27.0

Feed Spacer mil 31 46 31 46

mm 0.8 1.1 0.8 1.1

Test conditions: 5,000 mg/l MgSO4 in deionized water at 95 psi (6.5 bar) applied pressure, 10% recovery, 77°F (25°C), pH 7.5

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

23


KOCH Membrane Elements ROMIPRO Seies - Hollow Fiber Cartridges for Foood and Pharmaceutical Applications ROMIPRO™ cartridges should be selected for filtration of food and pharmaceutical water and intermediates when the required separation is in the range of 10,000 to 500,000 daltons. The ROMIPRO cartridges provide stable productivity, ease of cleaning and reliable operation. ROMIPRO cartridges are crossflow-type filters, in which the feed solution is pumped across the cartridge to minimize solids cake buildup on the membrane. Crossflow filters provide efficient filtration at low operating pressure, allowing long process runs while reducing cleaning time, cleaning frequency, and labor costs.

Membrane material: Polysulfone Membrane Type: Hollow Fiber Ultrafiltration Housing Construction: Polysulfone Seal/Potting Material: Proprietary Epoxy Compound Storage Solution: Glycerin Regulatory and Quality Information: All cartridge components in contact with the process fluid have passed USP Class VI test guidelines. • Certificate of quality is included with each cartridge. • Change control notification procedures apply. • Applications: Operating Contditions Sugar & Starch Maximum Inlet Pressure: Protein Processing Maximum Transmembrane Pressure: Nutraceuticals Maximum Operating Temperature: Food & Feed Maximum Permeate Side Back Pressure: Juice Processing Maximum Differential Pressure Vinegar Industrial Biotechnology Solutions Allowable pH Pharmaceutical Intermediates Maximum Total Chlorine General Industrial (During Cleaning):

Membrane

• • • • • •

40 psi (2.8 bar) 35 psi (2.4 bar) 140°F (60°C) 20 psi (1.4 bar) 30 psi (2.1 bar) 1.5 - 13 @ 130°F (54°C) 200 ppm @ pH 10-10.5, @ 130°F (54°C) 0 ppm @ pH < 9.5

Dimension Model No. 3043 5043

A inch 43 43

B mm 1092 1092

inch 3 5

C mm 76 127

inch 40.9 38.625

D mm 1040 981

inch 4.0 6.0

mm 102 152

Ordering information Model No. 3043-25-43-PM10 3043-25-43-PM30 3043-25-43-PM100 3043-25-43-PM500 5043-132-20-PM10 5043-66-43-PM10 5043-66-43-PM100 5043-66-43-PM500

24

Dia × L (inch) 3 x 40 3 x 40 3 x 40 3 x 40 5 x 38 5 x 38 5 x 38 5 x 38

Membrane Type PM10 PM30 PM100 PM500 PM10 PM10 PM100 PM500

MWCO (Dalton) 10,000 30,000 100,000 500,000 10,000 30,000 100,000 500,000

sales@acropore.com

Membrane Area (ft2) (m2) 25 2.3 25 2.3 25 2.3 25 2.3 132 12.3 66 6.1 66 6.1 66 6.1

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Feed Spacer mil 43 43 43 43 20 43 43 43

mm 1.1 1.1 1.1 1.1 0.5 1.1 1.1 1.1


KOCH Membrane Elements Super-Cor Series - Ultrafiltration Tabular Multitube Modules for Juice and Beverage Processing From processing golden, haze-free apple juice to ensuring excellent color passage in dark juices, Super-Cor offers juice clarification technology for all juices and production requirements, providing significantly increased yields of higher-quality juice with less maintenance than conventional methods. Super-Cor UF Multitube Modules easily remove suspended solids, colloidal haze particles, microorganisms, and undesirable proteins, leaving a crystal clear, flavorful juice. Super-Cor offers filtered juice yields of 96-99%, producing more juice per bushel and higher profits per gallon without the need for diatomaceous earth (DE). Super-Cor juice clarification solutions are durable and long-lasting, which means optimal productivity, high flux, and high recovery.

• • • • • •

Membrane Material: PVDF Membrane Type: Tabular Ultrafiltration Molecular Weight Cutoff*: 100,000 -500,000 Daltons Configuration: Nineteen (19) ½” diameter tubules in a polysulfone shell Applications: Juice and Beverage processing Regulatory Information: Compliant with food contact regulations per US FDA CFR Title 21, EC Reg. No. 1935/2004 and EU Reg. No. 10/2011 • Applications: Sugar & Starch Juice Processing Wine Industrial Biotechnology Solutions

Maximum Chlorine (cleaning):

90 psi (6.2 bar) @ 120°F (49°C) 10 psi (0.7 bar) 3 psi (0.2 bar) Per Module : 4-5 psi (0.27-0.35 bar) Per Module : 5 psi (0.35 bar) @ 120°F (49°C) Continuous 120°F (49°C) Short term 130°F (54°C) Continuous 2.0 – 10.0 Short term 1.5 – 10.5 200 ppm @ pH 10-10.5, 120°F (49°C)

Membrane

Operating Contditions Typical Operating Pressure: Minimum Outlet Pressure: Maximum Permeate Pressure: Typical Feed Side Pressure Drop Maximum Feed Side Pressure Drop Maximum Operating Temperature at pH 8: Allowable pH at @ 120°F (49°C)

Ordering information Model No. SUPER-COR® 3010-HFM-180 SUPER-COR® 3010-HFM-513

Dia × L (inch) 3 x 120 3 x 120

MWCO (Dalton) 100,000 500,000

Applications Light juices All juices

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Membrane Area (ft2) 24 24

(m2) 2.2 2.2

25


TORAY Membrane Elements TM700 Series - High Rejection RO Elements for high salinity brackish water applications • • • • • •

Membrane Chemistry: Cross Linked Fully Aromatic Polyamide Composite Membrane Type: TM700D High rejection Membrane Type: TM700C High rejection, 95% Boron rejection Membrane Type: TM700L High rejection, Low pressure Construction: Spiral wound with fiberglass outerwrap Applications: high salinity brackish water applications Municipal Water Solutions Municipal Wastewater Water Reuse Process Water Food & Beverage Wastewater Treatment Metal Finishing Water Reuse Power Solutions Mining Water Solutions Semiconductor Solutions Bottled Water Water Recovery

Recommended Operating Conditions and Technical Information Maximum Operating Pressure: 600 psi (4.14 MPa) Maximum Feed Water Temperature: 113°F (45°C) Maximum Feed SDI (15 min test): 5 Feed Water Chlorine Concenration: < 0.1 ppm Continuous Operation: 2 - 11 Allowable pH Short Term Cleaning: 1 - 13 per Element: 20 psi (0.14 MPa) Maximum Differential Pressure per Vessel: 60 psi (0.44 MPa)

B

Concentrated Brine

F

0.75(19)

TM710D

Feed Water

F

4(101)

Flow direction

1.05(26)

F

B PERMEATE B

40(1,016)

TM720DA400 TM720D-400 TM720D-440 F TM720C-440 TM720L-400 F TM720L-440

7.9(201)

Flow direction

1.125(29)

Membrane

Dimensions : shown in Inches (mm)

B PERMEATE B

40(1,016)

Ordering information Model No. TM710D TM720DA400 TM720D-400 TM720D-440 TM720C-440 TM720L-400 TM720L-440

Dia × L (inch) 4 × 40 8 × 40 8 × 40 8 × 40 8 × 40 8 × 40 8 × 40

Membrane Area (ft2) (m2) 87 8 400 37 400 37 440 41 440 41 400 37 440 41

Permeate Flow Rate gpd3 lpd4 2,600 9,800 11,000 41,600 11,000 41,600 12,100 45,800 9,000 34,100 8,500 32,200 9,400 35,600

lph5 408 1,733 1,733 1,908 1,420 1,341 1,483

Test Conditions: 2,000 mg/l NaCl solution at 225 psi (1.55 MPa) applied pressure, 15% recovery, 77°F (25°C) and pH 7.0 3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

26

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Salt Rejection (%) 99.8 99.8 99.8 99.8 99.2 99.5 99.5

Feed Spacer mil mm 31 0.8 31 0.8 34 0.9 28 0.7 28 0.7 31 0.8 28 0.7


TORAY Membrane Elements TMG, TMH Series - Ultra Low Pressure RO Elements for low salinity brackish water applications • • • • •

Membrane Chemistry: Cross Linked Fully Aromatic Polyamide Composite Membrane Type: TMG Low pressure Membrane Type: TMH Ultra Low pressure Construction: Spiral wound with fiberglass outerwrap Applications: high salinity brackish water applications Municipal Water Solutions Municipal Wastewater Water Reuse Process Water Food & Beverage Wastewater Treatment Metal Finishing Water Reuse Power Solutions Mining Water Solutions Semiconductor Solutions Bottled Water Water Recovery

Recommended Operating Conditions and Technical Information Maximum Operating Pressure: 365 psi (2.5 MPa) Maximum Feed Water Temperature: 113°F (45°C) Maximum Feed SDI (15 min test): 5 Feed Water Chlorine Concenration: Not detectable Continuous Operation: 2 - 11 Allowable pH Short Term Cleaning: 1 - 12 per Element: 20 psi (0.14 MPa) Maximum Differential Pressure per Vessel: 60 psi (0.44 MPa)

B

Concentrated Brine

F

0.75(19)

TMG10A

Feed Water

F

B PERMEATE B

40(1,016)

1.125(29)

7.9(201)

Flow direction TMG20-370C TMG20-400C TMG20N-400C F TMG20-440C TMH10A F TMH20A-370 TMH20A-400 TMH20A-440

B PERMEATE B

Membrane

Flow direction

1.05(26)

F

4(101)

Dimensions : shown in Inches (mm)

40(1,016)

Ordering information Model No. TMG10A TMG20-370C TMG20-400C TMG20N-400C TMG20-440C TMH10A TMH20A-370 TMH20A-400 TMH20A-440

Dia × L (inch) 4 × 40 8 × 40 8 × 40 8 × 40 8 × 40 4 × 40 8 × 40 8 × 40 8 × 40

Membrane Area (ft2) (m2) 87 8 370 34 400 37 400 37 440 41 87 8 370 34 400 37 440 41

Permeate Flow Rate gpd3 lpd4 2,400 9,100 9,500 36,000 10,200 38,600 10,200 38,600 11,300 42,600 2,400 9,100 10,200 38,600 11,000 41,600 12,100 45,700

lph5 379 1,500 1,608 1,608 1,775 379 1,608 1,733 1,904

Salt Rejection (%) 99.5 99.5 99.5 99.5 99.5 99.3 99.3 99.3 99.3

Feed Spacer mil mm 31 0.8 34 0.9 31 0.8 34 0.9 28 0.7 31 0.8 34 0.9 28 0.7 28 0.7

Test Conditions: 2,000 mg/l NaCl solution at 100 psi (0.69 MPa) applied pressure, 15% recovery, 77°F (25°C) and pH 7.0 3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

27


TORAY Membrane Elements TM800 Series - High Rejection RO Elements for sea water applications • • • • • • •

Membrane Chemistry: Cross Linked Fully Aromatic Polyamide Composite Membrane Type: TM800C, TM800M stabdard Membrane Type: TM800E, TM800R High Flow Membrane Type: TM800V, Low Energy Membrane Type: TM800K, Highest rejection Construction: Spiral wound with fiberglass outerwrap Applications: sea water

Recommended Operating Conditions and Technical Information Maximum Operating Pressure: 1,200 psi (8.3 MPa) Maximum Feed Water Temperature: 113°F (45°C) Maximum Feed SDI (15 min test): 5 Feed Water Chlorine Concenration: Not detectable Continuous Operation: 2 - 11 Allowable pH Short Term Cleaning: 1 - 12 per Element: 20 psi (0.14 MPa) Maximum Differential Pressure per Vessel: 60 psi (0.44 MPa)

Flow direction

1.05(26)

Feed Water

B

Concentrated Brine

F

0.75(19)

TM810C TM810V

F

PERMEATE B

7.9(201)

Flow direction

TM820C-400 TM820M-400 TM820M-440 TM820E-400 F TM820R-400 TM820R-440 F TM820V-400 TM820V-440 TM820K-400 TM820K-440

B PERMEATE B

40(1,016)

Ordering information Model No. TM810C TM820C-400 TM820M-400 TM820M-440 TM820E-400 TM820R-400 TM820R-440 TM810V TM820V-400 TM820V-440 TM820K-400 TM820K-440

Dia × L (inch) 4 × 40 8 × 40 8 × 40 8 × 40 8 × 40 8 × 40 8 × 40 4 × 40 8 × 40 8 × 40 8 × 40 8 × 40

Membrane Area (ft2) (m2) 73 7 400 37 400 37 440 41 400 37 400 37 440 41 73 7 400 37 440 41 400 37 440 41

Permeate Flow Rate gpd3 lpd4 1,200 4,500 6,500 24,600 7,000 26,500 7,700 29,200 7,500 28,300 8,500 32,200 9,400 35,600 1,900 7,200 9,000 34,100 9,900 37,500 5,800 21,900 6,400 24,200

lph5 187 1,025 1,104 1,216 1,179 1,341 1,483 300 1,420 1,562 912 1,008

Salt Rejection (%) 99.75 99.75 99.75 99.8 99.75 99.8 99.8 99.8 99.8 99.8 99.86 99.86

Test Conditions: 32,000 mg/l NaCl solution at 800 psi (5.52 MPa) applied pressure, 15% recovery, 77°F (25°C) and pH 7.0 3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

28

B

40(1,016)

1.125(29)

Membrane

F

4(101)

Dimensions : shown in Inches (mm)

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Feed Spacer mil mm 31 0.8 34 0.9 34 0.7 28 0.7 34 0.9 34 0.9 28 0.7 28 0.7 34 0.9 28 0.7 34 0.9 28 0.7


TORAY Membrane Elements TML Series - Low Fouling RO Elements for high fouling potential water applications • • • •

Membrane Chemistry: Cross Linked Fully Aromatic Polyamide Composite Membrane Type: TML Low fouling and high tolerance Construction: Spiral wound with fiberglass outerwrap Applications: high fouling potential water applications Municipal Water Solutions Municipal Wastewater Water Reuse Process Water Food & Beverage Wastewater Treatment Metal Finishing Water Reuse Power Solutions Mining Water Solutions Semiconductor Solutions Bottled Water Water Recovery

Recommended Operating Conditions and Technical Information Maximum Operating Pressure: 600 psi (4.1 MPa) Maximum Feed Water Temperature: 113°F (45°C) Maximum Feed SDI (15 min test): 5 Feed Water Chlorine Concenration: Not detectable Continuous Operation: 2 - 11 Allowable pH Short Term Cleaning: 1 - 13 per Element: 15 psi (0.10 MPa) Maximum Differential Pressure per Vessel: 50 psi (0.34 MPa)

Flow direction

1.05(26)

Feed Water

B

Concentrated Brine

0.75(19)

F F

B PERMEATE B

40(1,016)

1.125(29)

TML20D-370 F TML20DA400 TML20D-400 F

7.9(201)

Flow direction B PERMEATE B

Membrane

TML10D

F

4(101)

Dimensions : shown in Inches (mm)

40(1,016)

Ordering information Model No. TML10D TML20D-370 TML20DA400 TML20D-400

Dia × L (inch) 4 × 40 8 × 40 8 × 40 8 × 40

Membrane Area (ft2) (m2) 87 8 370 34 400 37 400 37

Permeate Flow Rate gpd3 lpd4 1,900 7,200 9,700 36,700 10,500 39,700 10,500 39,700

lph5 300 1,529 1,654 1,654

Salt Rejection (%) 99.8 99.8 99.8 99.8

Feed Spacer mil mm 34 0.9 34 0.9 31 0.8 34 0.9

Test Conditions: 2,000 mg/l NaCl solution at 225 psi (1.55 MPa) applied pressure, 15% recovery, 77°F (25°C) and pH 7.0 3 gpd: gallon per day, 4 lpd: liter per day, 5 lph: liter per hour

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

29


TORAY Membrane Elements TMRO Series - Sanitary RO Elements for Pharmaceutical, Food and Beverage applications • • • • •

Membrane Chemistry: Cross Linked Fully Aromatic Polyamide Composite Membrane Type: Sanitaty RO element Construction: Net-wrapped Spiral wound FDA Compliant Applications: Pharmaceutical, Food and Beverage

Membrane

Recommended Operating Conditions and Technical Information TMRO, TRO Maximum Operating Pressure: 600 psi (41.0 bar) Maximum Feed Water Temperature: 185°F (85°C) Maximum Feed Water Temperature: 122°F (50°C) Feed Water Chlorine Concenration: Not detectable Continuous Operation: 2.5-10.5 Allowable pH Short Term Cleaning: 1.7-11.5 per Vessel: 60 psi (4.0 bar) Maximum Differential Pressure per Element: 15 psi (1.0 bar)

Flow direction

TRO-HP 800 psi (55.2 bar) 150°F (65°C) 122°F (50°C) Not detectable Continuous Operation: 2.5-10.5 Short Term Cleaning: 1.7-11.5 per Vessel: 60 psi (4.0 bar) per Element: 15 psi (1.0 bar)

F

Feed Water

B

Concentrated Brine

B

F C

B

F

PERMEATE B

A

Ordering information Model No. TMRO-4040-HS TMRO-8040-HS TMRO-8040-NW TRO-3838 TRO-3838-N2 TRO-8038 TRO-8038-N2 TMRO-8040-PS TRO-3838HP TRO-8038HP TRO-8038HP-N2 TMRO-8040HP TMRO-8040HP-N2

30

TMRO-NW 800 psi (55.2 bar) 122°F (50°C) 122°F (50°C) Not detectable Continuous Operation: 2.5-10.5 Short Term Cleaning: 1.7-11.5 per Vessel: 60 psi (4.0 bar) per Element: 15 psi (1.0 bar)

Length (A) 40 (1016) 40 (1016) 40 (1016) 38 (965) 38 (965) 38 (965) 38 (965) 40 (1016) 38 (965) 38 (965) 38 (965) 40 (1016) 40 (1016)

Dimension, Inch (mm) OD (B) 4.0 (101) 7.9 (201) 7.9 (201) 3.8 (97) 3.8 (97) 7.9 (201) 7.9 (201) 7.9 (201) 3.8 (97) 7.9 (201) 7.9 (201) 7.9 (201) 7.9 (201)

sales@acropore.com

Spacer Thickness Inch (mm) 0.031 (0.79) 0.031 (0.79) 0.031 (0.79) 0.031 (0.79) 0.046 (1.17) 0.031 (0.79) 0.046 (1.17 0.031 (0.79) 0.031 (0.79) 0.031 (0.79) 0.046 (1.17 0.031 (0.79) 0.031 (0.79)

Tube ID (C) 0.75 (19) 1.125 (28.6) 1.125 (28.6) 0.83 (21) 0.83 (21) 1.125 (28.6) 1.125 (28.6) 1.125 (28.6) 0.83 (21) 1.125 (28.6) 1.125 (28.6) 1.125 (28.6) 1.125 (28.6)

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Membrane Area (ft2) 85 390 400 85 68 390 312 390 85 390 312 390 312

(m2) 7.9 36 37 7.9 6.3 36 29 36 7.9 36 29 36 29


TORAY Membrane Elements TNF Series - Sanitary NF Elements for Pharmaceutical, Food and Beverage applications • Membrane Chemistry: Cross Linked Fully Aromatic Polyamide Composite • Membrane Type: Sanitaty Nano Filtration element, selected specialty for sugar & protiens concentration with minimum lost of monovalent ions • Construction: Net-wrapped Spiral wound • FDA Compliant • Applications: Pharmaceutical, Food and Beverage Recommended Operating Conditions and Technical Information Maximum Operating Pressure: 800 psi (55.2 bar) Maximum Feed Water Temperature: 122°F (50°C) Maximum Feed Water Temperature: 122°F (50°C) Feed Water Chlorine Concenration: Not detectable Continuous Operation: 3.5-10.5 Allowable pH Short Term Cleaning: 1.8-11.5 per Vessel: 60 psi (4.0 bar) Maximum Differential Pressure per Element: 15 psi (1.0 bar)

Flow direction

F

Feed Water

B

Concentrated Brine

B

F C

F

PERMEATE

B

B

Ordering information Model No. TRO-3838 TRO-3838-N2 TRO-8038 TRO-8038-N2 TMRO-8040-PS TMRO-8040-PS-N2

Length (A) 38 (965) 38 (965) 38 (965) 38 (965) 40 (1016) 40 (1016)

Dimension, Inch (mm) OD (B) 3.8 (97) 3.8 (97) 7.9 (201) 7.9 (201) 7.9 (201) 7.9 (201)

sales@acropore.com

Spacer Thickness Inch (mm) 0.031 (0.79) 0.046 (1.17) 0.031 (0.79) 0.046 (1.17 0.031 (0.79) 0.031 (0.79)

Tube ID (C) 0.83 (21) 0.83 (21) 1.125 (28.6) 1.125 (28.6) 1.125 (28.6) 1.125 (28.6)

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Membrane Area (ft2) 80 68 360 280 360 280

(m2) 7.4 6.0 33.5 26 33.5 26

Membrane

A

31


TORAY Membrane Elements TUF Series - Sanitary UF Elements for Dairy applications • Membrane Chemistry: hydrophilic Polyethersulfone Asymmetric Membrane • Membrane Type: Sanitaty UF element, developed specially for milk and whey proteins concentration • Nominal Molecular Weight Cut-off: TUF10K; 10,000 Daltons • Nominal Molecular Weight Cut-off: TUF5K; 5,000 Daltons • Construction: Net-wrapped Spiral wound • FDA Compliant • Applications: Dairy Recommended Operating Conditions and Technical Information Maximum Operating Pressure: 140 psi (9.7 bar) Maximum Feed Water Temperature: 131°F (55°C) Maximum Feed Water Temperature: 122°F (50°C) Feed Water Chlorine Concenration: 180 ppm Continuous Operation: 2.5-10 Allowable pH Short Term Cleaning: 1.7-11.5 per Vessel: 60 psi (4.0 bar) Maximum Differential Pressure per Element: 15 psi (1.0 bar)

Flow direction

F

Feed Water

B

Concentrated Brine

B

F C

B

Membrane

F

32

PERMEATE B

A

Ordering information Model No. TUF10K-3838-HRN1 TUF10K-3838-HRN2 TUF10K-6338-HRN1 TUF10K-6438-HRN1 TUF10K-6338-HRN2 TUF10K-6438-HRN2 TUF10K-6338-HRN3 TUF10K-6438-HRN3 TUF10K-8038-HRN1 TUF10K-8038-HRN2 TUF5K-3838-HRN1 TUF5K-3838-HRN2 TUF5K-6338-HRN1 TUF5K-6438-HRN1 TUF5K-6338-HRN2 TUF5K-6438-HRN2 TUF5K-6338-HRN3 TUF5K-6438-HRN3 TUF5K-8038-HRN1 TUF5K-8038-HRN2 TUF5K-8038-HRN3

Length (A) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965)

Dimension, Inch (mm) OD (B) 3.8 (97) 3.8 (97) 6.3 (160) 6.3 (161) 6.3 (160) 6.3 (161) 6.3 (160) 6.3 (161) 7.9 (201) 7.9 (201) 3.8 (97) 3.8 (97) 6.3 (160) 6.3 (161) 6.3 (160) 6.3 (161) 6.3 (160) 6.3 (161) 7.9 (201) 7.9 (201) 7.9 (201)

sales@acropore.com

Spacer Thickness Inch (mm) 0.031 (0.79) 0.046 (1.17) 0.031 (0.79) 0.031 (0.79) 0.046 (1.17) 0.046 (1.17) 0.065 (1.65) 0.065 (1.65) 0.031 (0.79) 0.046 (1.17) 0.031 (0.79) 0.046 (1.17) 0.031 (0.79) 0.031 (0.79) 0.046 (1.17) 0.046 (1.17) 0.065 (1.65) 0.065 (1.65) 0.031 (0.79) 0.046 (1.17) 0.065 (1.65)

Tube ID (C) 0.83 (21) 0.83 (21) 1.138 (28.9) 1.138 (28.9) 1.138 (28.9) 1.138 (28.9) 1.138 (28.9) 1.138 (28.9) 1.125 (28.6) 1.125 (28.6) 0.83 (21) 0.83 (21) 1.138 (28.9) 1.138 (28.9) 1.138 (28.9) 1.138 (28.9) 1.138 (28.9) 1.138 (28.9) 1.125 (28.6) 1.125 (28.6) 1.125 (28.6)

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Membrane Area (ft2) 80 60 200 200 150 150 122 122 360 280 80 60 200 200 150 150 122 122 360 280 230

(m2) 7.4 5.6 19 19 14 14 11.5 11.5 33.5 26 7.4 5.6 19 19 14 14 11.5 11.5 33.5 26 21.4


TORAY Membrane Elements HF Series - Hollow fiber Ultrafiltratiom Modules for sea water applications • • • • •

Hollow Fiber Material : PVDF (Polyvinylidene fluoride) Type: HFU 0.01 micron for drinking water production Type: HFU 0.02 micron for waste or industrial water treatment Construction: Hollow fiber in PVC module Applications: Drinking Water Production Tertiary Treatment of Sewage Water RO Pretreatment in Seawater Desalination Industrial Water Production Reuse of Industrial Waste Water

Recommended Operating Conditions and Technical Information Maximum Feed Pressure: 43.5 psi (300 kPa) Minimum Feed Temperature: 32°F (0°C) Maximum Feed Temperature: 104°F (40°C) Continuous Operation: 1 - 10 Allowable pH Short Term Cleaning: 0 - 12

Model No. HFU-2020N HFU-1020N HFU-2020N HFU-1020N

Dia × L (inch) 8.5 × 85 8.5 × 44 8.5 × 85 8.5 × 44

Membrane Area (ft2) 775 312 775 312

sales@acropore.com

Nominal MWCO (Da) 150,000 150,000 300,000 300,000

(m2) 72 29 72 29

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

Nominal Por size (um) 0.01 0.01 0.02 0.02

Design Flux (m3/h) 8.0-2.6 3.2-1.1 11.0-2.4 4.3-1.0

Membrane

Ordering information

33


Membrane Cleaners Membrane Cleaning Chemicals Membrane cleaning chemicals has been formulated by proprietary chemicals. These products are a result of over 20 years of hands-on experience of engineers and chemists. We offer technical expertise and assistance in troubleshooting and cleaning of RO membranes to give you an optimum system performance. Features

• Membrane cleaners are sold in powder form in 25lb containers. (Some are available in 5lb. containers as well.) • Mixing and cleaning instructions, product specifications, and MSDS sheets are included with each container. • Acid and Alkaline Cleaners to Regularly Clean RO Membranes: • Maintain System Performance at a Higher Level and Prolong Membrane Life

Membrane Cleaning Cartridges Clean Membranes Without Removing them from Your System Reduce Downtime Maintain Your System Performance at a Higher Level Prolong Membrane Life by Regular Use of Cleaning Cartridge Designed to Fit Standard and Big Blue Filter Housings in 10” & 20” Lengths • For use on Thin Film Membranes in Systems up to 20,000 GPD

Membrane

• • • • •

Ordering information Model No. To Remove Membrane Cleaning Chemicals AM-11-25 Mineral Scale, Hardness, Iron, Barium Sulfate, Etc. AM-11-5 AM-22-25 Biofilms, Organics AM-22-5 AM-23-25* Silica, Biofilms, Organics AM-33-25 Biofilms, Organics AM-44-25 Hardness, Iron, Metal Scales AM-55-25 Colloids(Silt), Biofilm, Organics AM-99-25 Silica, Silicates AM-124-25 Iron Deposits

pH

For Membrane Type

Acid

Thin Film (TF)

Alkaline

Thin Film (TF)

Alkaline Alkaline Acid Alkaline Acid Acid

Thin Film (TF) CA/CTA CA/CTA TF, CTA, MF, UF Thin Film (TF) TF, CA/CTA

Container size 25 lb 5 lb 25 lb 5 lb 25 lb 25 lb 25 lb 25 lb 25 lb 25 lb

* Items marked with an asterisk are classified as DOT hazardous materials and cannot be shipped by UPS or by air. Can be shipped by ground common carrier or ocean shipment only.

Ordering information Model No. Containg Membrane Cleaning Cartridges C-C2510-A11 AM-11 (Acid) C-C2520-A11 AM-11 (Acid) C-C4210-A11 AM-11 (Acid) C-C4220-A11 AM-11 (Acid) C-C2510-A22 AM-22 (Alkaline) C-C2520-A22 AM-22 (Alkaline) C-C4210-A22 AM-22 (Alkaline) C-C4220-A22 AM-22 (Alkaline) C-C2510-A23* AM-23 (Alkaline) C-C2520-A23* AM-23 (Alkaline)

To Remove

Mineral Scale, Hardness, Iron, Barium Sulfate, Etc.

Biofilms, Organics

Silica, Biofilms, Organics

For Housing Size

Repeatability

10” Standard 20” Standard 10” Big Blue 20” Big Blue 10” Standard 20” Standard 10” Big Blue 20” Big Blue 10” Standard 20” Standard

1 1 to 2 2 to 3 4 to 6 1 1 to 2 2 to 3 4 to 6 1 1 to 2

* Items marked with an asterisk are classified as DOT hazardous materials and cannot be shipped by UPS or by air. Can be shipped by ground common carrier or ocean shipment only.

34

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com


Membrane Cleaners Membrane Cleaning System Membrane Cleaning Reverse Osmosis membrane elements can experience a decline in performance due to the accumulation of deposits on the membrane surface. Mineral scale, colloidal particles, biological matter, and insoluble organic compounds are the usual causes of membrane fouling. When production of a Reverse Osmosis system drops by at least 10 percent, or the differential pressure increases by 15 percent (over normal operating conditions), membrane cleaning should be performed Acid and Caustic cleaning chemicals are most commonly used for membrane cleaning. Acid cleaners are designed to remove inorganic and iron deposits. Acid (low pH) cleaning should be performed at a pH of about 2. Caustic (high pH) cleaners are designed for removal of biological matter, organic foulants, and silica deposits. Caustic cleaning is performed at a pH of about 12.

System

Ordering information Pressure vessel to be cleaned Model number Size Quantity AF-MC-41 4” 1 AF-MC-42 4” 2 AF-MC-43 4” 3 AF-MC-44 4” 4 AF-MC-81 8” 1 AF-MC-82 8” 2 AF-MC-83 8” 3 AF-MC-84 8” 4 AF-MC-85 8” 5 AF-MC-86 8” 6

Max Flow (Liter/minute) 100 100 200 200 200 300 500 700 1,000 1,000

sales@acropore.com

Connection (inch) 1” 1” 1” 1.5” 1.5” 1.5” 2” 2” 3” 3”

®

ACROPORE

Your Water Filtration Specialists

Tank Capacity (Litre) 200 400 600 800 800 800 1,200 1,500 2,000 2,500

www.acropore.com

Dimension (inch) 48 x 35 x 60 50 x 35 x 60 65 x 40 x 75 65 x 40 x 75 65 x 40 x 75 65 x 40 x 75 85 x 55 x 90 85 x 55 x 100 85 x 55 x 100 85 x 55 x 100

Weight (kg) 135 200 250 275 275 275 300 325 350 375

Membrane

The cleaning system is designed to be used with any RO system to clean membrane withou removing membrane form the system. A chemical storage tank is mounted on its own stand and connected to the skid with either hard piping or quick disconnect fittings and flexible hoses. This gives the unit the ability to be mounted in a permanent location as a CIP (Clean In Place) or portable if desired.

35


Systems and Options RO Systems

●● Series PRO44, capacity of 0.25 - 1.5 m3/hr ●● Series PRO48, capacity of 1.5 - 3.0 m3/hr ●● Series PRO88, capacity of 6-18 m3/hr

Ultra Filtration (UF) Systems

●● ●● ●● ●●

Capacity of 0.75 - 100 m3/hr Low fouling Hydrophilic Polyvinylidenefluoride (H-PVDF) membrane Excellent filtration performance with high flux Can be periodically back washed and air scoured to improve performance and extend operating life by removing the fouling layer

Water Deionizers

Water deionizers are used in applications requiring very high water quality, usually as polishers after reverse osmosis. Many industries use DI sytems: paints, chemicals, electronics, textiles, plating, cosmetics, boiler feed, food/beverage processing, hospitals/medical facilities.

Membrane

Water Softeners

Anthracite : for Sediment Removal Manganese Green Sand : for Stain Removal Activated Carbon : for Chlorine, Tastes and Oders Removal Cation Resin : for Hardness Removal Mixed-Bed Resin : for Salt Removal

Booster Pumps

For boosting the constant pressure to the filter tanks and offering smooth filtration and high effficiency. Consists of single or double pumps , diaphram pressure tank, pumpd controller with pressure swich or float swich.

Stainless Steel Multi-Cartridge Filters and Housing

Commercial Stainless Steel Multi-Cartridge Filter and Housings provide a high quality solution for high-volume filtering at reduced pricing. Ideal for use in post- filtration and more. Housings will fit standard 30” or 40” filter cartridges. Filters cartridges are nominal micron rating 1-150 micron.

UV Sterilizers

The quality of drinking water can change with time and become contaminated with harmful bacteria. Allfyll UV system is a reliable, economical and chemical-free way to safeguard drinking water.

Please request more information

36

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com


Membrane warranty Important Note: If a membrane performs as per specifications when first tested in the system (allowing for water temperature effect), then the membrane is good. Any performance decline after this has nothing to do with the membrane. The performance decline is due to one or more of the following: • Chlorine Leakage • Colloidal Particles or Suspended Solids • Hardness, Iron or other fouling • Microbiological Fouling • Physical Abuse • O-Ring Leak The water quality and the way the system is operated may lead to premature failure. It sometimes takes only a few hours to damage the membrane. The membrane does not lose its performance unless it is subjected to poor operating conditions or improper pretreatment. Performance problems at startup should be reported immediately. 1. Terms of Pro-rated Performance Warranty - Subject to the conditions set forth in Sections 3 and 4 below, Allfyll warrants the performance of its elements for one (1) year from whichever of the following events occurs first: a. First use in system; b. Three (3) months following date of shipment. 2. Initial Performance - Allfyll warrants the elements herein offered have the initial minimum permeate flow and initial minimum salt rejection as specified in the Technical Bulletin(s) when such elements are tested under standard conditions specified by Allfyll. a. Buyer is responsible for testing of each element to ensure element meets performance specified in the Technical Bulletin(s). b. Should any element not meet performance specifications, and Buyer notifies Allfyll of such deficiency within 10 days from date of testing of element(s) by Buyer, Allfyll will, upon confirmation of faulty performance, repair or replace the defective element(s) at no charge. Shipping costs, in such case, will be paid by Allfyll. 3. Performance During Three Year Warranty Period - During the first year of operation on the element(s), Allfyll warrants that minimum permeate flow, when operated under standard conditions published by Allfyll, shall be at least 70 percent of the specified initial average flow. Allfyll further warrants that maximum salt passage, when element is operated under standard conditions published by Allfyll and pressure required to give the initial rated flow, will not exceed 1.35x the specified maximum value. Allfyll will, on confirmation of loss of performance during the warranty period, credit 1/12 of the original purchase price of the element for each unused month of the warranty period toward the purchase of a replacement element and the current prevailing price.

5. Repair of Replacement - Allfyll’s obligation under this warranty and Buyer’s sole remedy for any breach of warranty is limited to and shall be fully discharged by Allfyll repairing any defective element or, at Allfyll’s discretion, replacing same at the then selling price f.o.b. Allfyll’s plant, plus a service and handling charge of thirty dollars ($30.00) per element, less a prorated rebate on the unrealized life of the warranty period. Allfyll reserves the right to test the alleged defective elements and the reverse osmosis systems on user’s or Buyer’s premises or to request Buyer to perform such inspections or tests and forward the results thereof to Allfyll. If the element failure is determined to be from cause other than breach of warranty as set forth above, Buyer shall pay to Allfyll a fee of $800 per day, plus direct travel expenses incurred by Allfyll’s employees, in connection with any inspection and testing of such elements and systems on Buyer’s premises. Elements shipped to Allfyll for warranty examination must be shipped freight prepaid. Elements examined as part of a warranty claim which are found to be performing as warranted will be returned to the Buyer freight collect and a handling charge will be levied against the Buyer, as described in the published Element Return Procedures Reminders • Permeate obtained from first hour of operation should be discharged. • Elements must be in use for at least 6 hours before formaldehyde is used as a biocide. If the elements are exposed to formaldehyde before this period, a severe loss in flux may result. • Neither nonionic nor cationic surfactants, nor any other chemical not approved by Allfyll, should be used for membrane cleaning or come in contact with • Allfyll elements. The customer is fully responsible for the effects of unapproved chemicals on Allfyll elements; their use will void the warranty. • Before returning any element(s) to Allfyll for warranty examination, see the Element Return Procedures technical bulletin.

Membrane

4. Conditions of Warranty The performance warranty described in section 3 above shall be null and void if any of the following conditions are not met: a. The feedwater to the element(s) shall have less than one (1) NTU turbidity and a silt density index at 15 mins. (SDI15) of less than 5.0; b. The feedwater to the element(s) shall contain no oil, grease, or other organic or inorganic matter harmful to the membrane; c. The feedwater temperature shall not exceed 113°F (45°C). The element(s) shall not be exposed during operation, cleaning, or in shutdown periods, to pH outside the range given in specification sheet and adequate provisions against microbiological contamination shall be incorporated into the system and design, as well as into all operating and maintenance procedures. The element(s) shall not be exposed to pressure outside the limit in the specification sheet; d. Backpressure (where permeate static pressure exceeds reject static pressure) shall not exceed 5 psi at any time; e. The element(s) shall be operationally protected against hydraulic shock loading (water hammer); f. The element(s) shall be maintained in a clean condition, unfouled by particulate matter or precipitates or biological growth; If scaling or fouling should occur, or normalized element flow decline 10%, cleaning procedures should be initialized; g. The system array, recovery, and instrumentation, and the design parameters and components of the system in which the element(s) are employed, shall be consistent with sound engineering practice; h. Buyer is responsible for providing the user with the adequate system operating and maintenance manuals, operator and supervisor training, and ensuring user’s ability to perform cleaning and other performance restoration and diagnostic procedures; i. Buyer shall ensure that frequent, adequate system and subsystem performance data are routinely logged, reviewed, and filed in a systematic format, such information to be available to AMI on a reasonable basis in the event a claim is made against AMI pursuant to this performance warranty.

6. UF & MF Membranes & Systems for Non-Water Treatment Applications - The performance of membranes for process and waste water applications is difficult to predict. Each situation is different in the liquid composition and can drastically change the performance of the membrane, its fouling and useful life. Allfyll makes no specific claims on the permeate flow, rejection or membrane life for these applications. This information must come from the customer either from prior experience or from pilot testing under actual process conditions. Allfyll can only provide flux information with non-fouling water. The molecular weight cut-off information is a guideline number and must be treated as such. Different compounds with similar molecular weight cut-offs can behave very differently in their rejection by a membrane. Also, different material membranes with the same MWCO may mean different rejections for the same compound. In short, for process and waste water applications the customer must take the responsibility of the membrane performance. Allfyll will honor warranty only if the initial non-fouling water permeate flow under the test conditions is lower or if there is an initial mechanical defect. No performance warranty is given or implied by anyone or any sales literature from Allfyll. Warranty Notice - Failure or refusal to fully disclose to Allfyll the use and operating parameters of Allfyll membrane elements shall render all warranties other than that covering materials and workmanship null and void.*The warranty information above is Allfyll. membrane warranty, and pertains to membrane elements manufactured by Allfyll. For other manufacturers, their individual warranties will apply.

sales@acropore.com

®

ACROPORE

Your Water Filtration Specialists

www.acropore.com

37


ACROPORE

Your Water Filtration Specialists

Membranes

Membrane

for Industrial Water Filtration

Acropore Technology Co.,Ltd.

Head Office: 8 Thaiyanon 12, Nonthaburi 46 Rd., Muang, Nonthaburi TEL: 02950-2121-2, FAX: +66 2950-2120 Khonkan Office: 157/18-19, Mitraphab Rd., Muang, Khonkan TEL: 043-042582, FAX: 043-042581 Surathani Office: 189/1, Tambol Watpradoo, Muang, Surathani TEL: 092 4146929, 02950-2121-2, FAX: 02950-2120 Email: sales.th@acropore.com

ACROPORE www.acropore.com

Allfyll Vietnam Co., Ltd.

HCMC Office: 161 Vo Van Tan street, Ward 6, District 3, HCMC TEL: +84-8-3933 3599, FAX: +84-8-3930 9610 Ha Noi Office: 160 Tay Son, Dong Da District, Hanoi TEL: +84-4-3533 5759, Fax: +84-4-3533 5760 Email: sales.vn@allfyll.com

Allfyll (Myanmar) Co., Ltd.

San Ward, Bahan Township, Yangon TEL: +95-1-557539, FAX: +95-1-557-539 38 Yangon Office: 141, West Race Course Rd., Kyaik Kasales@acropore.com ACROPORE www.acropore.com Email: sales.mm@allfyll.com

Your Water Filtration Specialists

PRODUCT OF THAILAND

Ct-MembraneEN-201505 息 2015 Printed in Thailand 05/2015


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.