Halovolt LF EMC

Page 1

PiPELifE wORLd widE

Pipelife European Electro Office Pipelife Office and Plant Pipelife Sales Office

European Electro Office: Pipelife Netherlands B.V. Flevolaan 7 1601 MA Enkhuizen Telephone: +31 (0) 228 355 555 www.pipelife.nl Contact: Mark Bakker

Patrick Verschuur

Sales Manager Electro Export

Product Manager Electro Export

e-mail: mark.bakker@pipelife.nl

e-mail: patrick.verschuur@pipelife.nl

mobile phone: +31 (0) 653 260 977

mobile phone: +31 (0) 646 789 609

NO MORE ELECTRO STRESS


MiNiMUM RAdiATiON iN BUiLdiNGS wiTH THE NEw HALOVOLT LOw fRiCTiON EMC PiPE fROM PiPELifE increasingly, people are consciously opting for a healthy lifestyle. People want to limit the harmful effects of the things around them as much as possible. Besides wanting clean air and healthy food, people also want to live and work in a low-radiation living and working environment. Pipelife serves this need perfectly with an important new innovation.

ASSORTMENT

Electromagnetic radiation at a too high level is

HALOVOLT, LOw fRiCTiON, EMC, HiGH iMPACT

harmful to people, believe scientists. For this

Classification: 3442 Color: RAL9005

reason, Pipelife has created a new product: the

Material: Halogen Free Diameter

Meter per

Meter in

Bundle per

Meter

Article

Halovolt Low Friction EMC. This electrical instal-

(mm)

Length (m)

Bundle (m)

Package

Package (m)

Number

lation pipe is intended to keep the emission of

16

3

75

60

4500

316805

20

3

75

40

3000

316807

electromagnetic radiation to the immediate environment to a minimum. It is the new standard

HALOVOLTfLEx, LOw fRiCTiON, EMC, HiGH iMPACT

for both public and private buildings.

Classification: 3442 Color: RAL9005

EMC radiation from electrical installation

Diameter

Meter

Article

(mm)

coil (m)

Number

16

100

316894

20

100

316895

768 v/m 312 v/m

HALOVOLT EMC SOCkET

29 v/m

Bad installation

Normal installation

Material: Halogen Free

EMC installation

PROTECTiON The Halovolt Low Friction EMC pipe from Pipelife is on the outside recognizably black. This is the protective outer layer. This outer layer facilitates the best possible protection against the electromagnetic radiation that wants to pass through the pipe. This outer layer blocks the EMC radia-

Color: RAL9005 Material: Halogen Free Diameter

Pieces per

Bag per

Article

(mm)

Bag

Package

Number

16

50

400

316898

20

50

400

316899

HALOVOLT EMC BENdS Color: RAL9005 Material: Halogen Free Diameter

Pieces per

Bag per

Article

(mm)

Bag

Package

Number

16

25

150

316902

20

25

125

316903

HALOVOLT EMC CONNECTORS Color: RAL9005

tion, so that no or very little EMC radiation es-

Material: Halogen Free

capes into the living or working environment

Diameter

Pieces per

Bag per

Article

(mm)

Carton

Package

Number

where the pipes are installed. It facilitates the best possible protection and keeps harmful EMC radiation to an absolute minimum.

16

316908

20

316909


MiNiMUM RAdiATiON iN BUiLdiNGS wiTH THE NEw HALOVOLT LOw fRiCTiON EMC PiPE fROM PiPELifE

COMPOSiTE iN THREE LAYERS A cross-section clearly shows that the Halovolt APPLiCATiONS

Low Friction EMC pipe from Pipelife comprises

The new Halovolt LF EMC pipe can be used in different buildings and installations. Every building and

three layers. The basic component is the original

installation has his own demands.

light-grey halogenfree pipe, which everyone is fa-

In an office building a Halovolt LF EMC installation can be installed for a cleaner environment. But can

miliar with. Earlier innovation is the red Low Fric-

also being installed for the shielding properties, protecting a data network. Those two applications

tion layer, which is fixed on the inside of the pipe.

can be used in all kinds of buildings.

This layer is extra smooth. The big advantage of

For example:

this is that the wiring can be pulled through the

-Residential houses

pipe more easily and quickly. The most recent in-

-Railway buildings

novation of Pipelife is now the outer layer, which

-Public buildings

protects the living and working environment

ELECTRO STRESS:

-Hospitals

from EMC radiation.

An increasing number of scientists believe that the limit

INCREASINg RADIATION VOLT PER METER AgAINST CONDuCTION AND PROTECTION

-Airports

for electromagnetic radiation should be much tighter. It

-Etc.

is a growing belief that the current limits in most European countries form a risk to our health. In the meantime, people are being exposed in their homes and workplaces to an increasing dose of nonionizing or electromagnetic radiation. International scientific studies reveal that too much electromagnetic radiation can lead to various physical complaints and diseases. They are collectively referred to as ‘electro stress’.


iNTERNATiONAL NORMS

CORPORATE SOCiAL RESPONSiBiLiTY

The Council of Europe compares electromagnetic radiation with

Pipelife cares about the environment and future of our

asbestos and tobacco, for which the harmful effects were also

planet! Since already some years we at Pipelife have

initially underestimated. The Council of Europe believes that

committed ourselves to sustainability, which plays an im-

waiting for scientific proof is foolish. For this reason, the Coun-

portant aspect in our daily business life, our production

cil of Europe stipulates strict radiation limits to prevent serious

processes and the products and services we offer.

health risks. Of course, one person suffers more than another

Careful use of raw materials, reduction of energy con-

from what is called ‘electro smog’; in this regard, one talks of

sumption, lowering our emissions and increased recy-

electro-sensitive people. Whatever is decided, the Halovolt LF

cling are only few examples of the broad range of tar-

EMC pipe from Pipelife already helps reduce electromagnetic

gets Pipelife dedicates itself to.

radiation in buildings and keeps it to an absolute minimum.

Pipelife engineered the Halovolt LF EMC pipe and fittings in a way that they are fully 100% recyclable. This makes the Halovolt LF EMC pipes and fittings not only good for

PROTECTiON Of dATA NETwORkS

kNx BUiLdiNG AUTOMATiON

The Halovolt LF EMC pipe is not only protecting

The new Halovolt LF EMC pipe can also be installed

the ambience against EMC radiation it can also be-

in a KNX installation. The pipe is not only protect-

ing used to protect the cable inside the Halovolt LF

ing the building against EMC radiation, but also

EMC pipe against outer interferences. This makes

protects the KNX data cable.

the Halovolt LF EMC pipe ideal to use in an data network installation. Now the data has an extra protection against outer interferences. This helps to reduce corrupted data and gives the data network installation a better reliability.

humans, but also of the environment.

HOw TO iNSTALL It’s very easy to install the Halovolt LF EMC. To upgrade the electro installation to an EMC installation the installer must only do two steps. First of all use the Halovolt LF EMC pipe in the installation. Second is using the Halovolt EMC Connector. HALOVOLT Lf EMC PiPE The Halovolt LF EMC pipe doesn’t require any special installing. The Halovolt LF EMC can be installed like a normal electrical installation pipe. EMC SOCkETS ANd EMC BENdS

HOw dOES iT wORk

When the Halovolt LF EMC pipes are connected

The Halovolt LF EMC pipe is based on the prin-

together with a EMC sock or EMC bend don’t use

ciple “Cage of Faraday”. The shielding properties

any glue. The glue will make an insulator between

of the cage of Faraday are very good.

the outer layer of the Halovolt LF EMC and the

Inside the cage is nearly no more EMC radiation.

EMC sock or EMC bend.

Pipelife implemented this technique in the Halovolt LF EMC pipe. When installing the Halovolt LF

EMC CONNECTOR

EMC pipe of Pipelife the installer is automatically

The EMC connector can be easily inserted into the

making a cage of Faraday. This is done due to the

pipe insert of the junction box. Than connect the

outer layer of the pipe who is conductive. When

Halovolt LF EMC pipe into the EMC Connector.

the outer layer of the Halovolt EMC pipe is than

And connect the wire from the EMC Connector to the “earth” wire of the installation.

connected to earth it will become an excellent cage of Faraday. Now the electrical installation

EMC JUNCTiON BOx

will emit significantly less EMC radiation.

For the best result it is recommended to use EMC junction boxes. Kaiser is a manufacture of EMC junction boxes. For details of the EMC Junction boxes you can contact Kaiser. For contact details got to their website: www.kaiser-elektro.de


iNTERNATiONAL NORMS

CORPORATE SOCiAL RESPONSiBiLiTY

The Council of Europe compares electromagnetic radiation with

Pipelife cares about the environment and future of our

asbestos and tobacco, for which the harmful effects were also

planet! Since already some years we at Pipelife have

initially underestimated. The Council of Europe believes that

committed ourselves to sustainability, which plays an im-

waiting for scientific proof is foolish. For this reason, the Coun-

portant aspect in our daily business life, our production

cil of Europe stipulates strict radiation limits to prevent serious

processes and the products and services we offer.

health risks. Of course, one person suffers more than another

Careful use of raw materials, reduction of energy con-

from what is called ‘electro smog’; in this regard, one talks of

sumption, lowering our emissions and increased recy-

electro-sensitive people. Whatever is decided, the Halovolt LF

cling are only few examples of the broad range of tar-

EMC pipe from Pipelife already helps reduce electromagnetic

gets Pipelife dedicates itself to.

radiation in buildings and keeps it to an absolute minimum.

Pipelife engineered the Halovolt LF EMC pipe and fittings in a way that they are fully 100% recyclable. This makes the Halovolt LF EMC pipes and fittings not only good for

PROTECTiON Of dATA NETwORkS

kNx BUiLdiNG AUTOMATiON

The Halovolt LF EMC pipe is not only protecting

The new Halovolt LF EMC pipe can also be installed

the ambience against EMC radiation it can also be-

in a KNX installation. The pipe is not only protect-

ing used to protect the cable inside the Halovolt LF

ing the building against EMC radiation, but also

EMC pipe against outer interferences. This makes

protects the KNX data cable.

the Halovolt LF EMC pipe ideal to use in an data network installation. Now the data has an extra protection against outer interferences. This helps to reduce corrupted data and gives the data network installation a better reliability.

humans, but also of the environment.

HOw TO iNSTALL It’s very easy to install the Halovolt LF EMC. To upgrade the electro installation to an EMC installation the installer must only do two steps. First of all use the Halovolt LF EMC pipe in the installation. Second is using the Halovolt EMC Connector. HALOVOLT Lf EMC PiPE The Halovolt LF EMC pipe doesn’t require any special installing. The Halovolt LF EMC can be installed like a normal electrical installation pipe. EMC SOCkETS ANd EMC BENdS

HOw dOES iT wORk

When the Halovolt LF EMC pipes are connected

The Halovolt LF EMC pipe is based on the prin-

together with a EMC sock or EMC bend don’t use

ciple “Cage of Faraday”. The shielding properties

any glue. The glue will make an insulator between

of the cage of Faraday are very good.

the outer layer of the Halovolt LF EMC and the

Inside the cage is nearly no more EMC radiation.

EMC sock or EMC bend.

Pipelife implemented this technique in the Halovolt LF EMC pipe. When installing the Halovolt LF

EMC CONNECTOR

EMC pipe of Pipelife the installer is automatically

The EMC connector can be easily inserted into the

making a cage of Faraday. This is done due to the

pipe insert of the junction box. Than connect the

outer layer of the pipe who is conductive. When

Halovolt LF EMC pipe into the EMC Connector.

the outer layer of the Halovolt EMC pipe is than

And connect the wire from the EMC Connector to the “earth” wire of the installation.

connected to earth it will become an excellent cage of Faraday. Now the electrical installation

EMC JUNCTiON BOx

will emit significantly less EMC radiation.

For the best result it is recommended to use EMC junction boxes. Kaiser is a manufacture of EMC junction boxes. For details of the EMC Junction boxes you can contact Kaiser. For contact details got to their website: www.kaiser-elektro.de


MiNiMUM RAdiATiON iN BUiLdiNGS wiTH THE NEw HALOVOLT LOw fRiCTiON EMC PiPE fROM PiPELifE

COMPOSiTE iN THREE LAYERS A cross-section clearly shows that the Halovolt APPLiCATiONS

Low Friction EMC pipe from Pipelife comprises

The new Halovolt LF EMC pipe can be used in different buildings and installations. Every building and

three layers. The basic component is the original

installation has his own demands.

light-grey halogenfree pipe, which everyone is fa-

In an office building a Halovolt LF EMC installation can be installed for a cleaner environment. But can

miliar with. Earlier innovation is the red Low Fric-

also being installed for the shielding properties, protecting a data network. Those two applications

tion layer, which is fixed on the inside of the pipe.

can be used in all kinds of buildings.

This layer is extra smooth. The big advantage of

For example:

this is that the wiring can be pulled through the

-Residential houses

pipe more easily and quickly. The most recent in-

-Railway buildings

novation of Pipelife is now the outer layer, which

-Public buildings

protects the living and working environment

ELECTRO STRESS:

-Hospitals

from EMC radiation.

An increasing number of scientists believe that the limit

INCREASINg RADIATION VOLT PER METER AgAINST CONDuCTION AND PROTECTION

-Airports

for electromagnetic radiation should be much tighter. It

-Etc.

is a growing belief that the current limits in most European countries form a risk to our health. In the meantime, people are being exposed in their homes and workplaces to an increasing dose of nonionizing or electromagnetic radiation. International scientific studies reveal that too much electromagnetic radiation can lead to various physical complaints and diseases. They are collectively referred to as ‘electro stress’.


MiNiMUM RAdiATiON iN BUiLdiNGS wiTH THE NEw HALOVOLT LOw fRiCTiON EMC PiPE fROM PiPELifE increasingly, people are consciously opting for a healthy lifestyle. People want to limit the harmful effects of the things around them as much as possible. Besides wanting clean air and healthy food, people also want to live and work in a low-radiation living and working environment. Pipelife serves this need perfectly with an important new innovation.

ASSORTMENT

Electromagnetic radiation at a too high level is

HALOVOLT, LOw fRiCTiON, EMC, HiGH iMPACT

harmful to people, believe scientists. For this

Classification: 3442 Color: RAL9005

reason, Pipelife has created a new product: the

Material: Halogen Free Diameter

Meter per

Meter in

Bundle per

Meter

Article

Halovolt Low Friction EMC. This electrical instal-

(mm)

Length (m)

Bundle (m)

Package

Package (m)

Number

lation pipe is intended to keep the emission of

16

3

75

60

4500

316805

20

3

75

40

3000

316807

electromagnetic radiation to the immediate environment to a minimum. It is the new standard

HALOVOLTfLEx, LOw fRiCTiON, EMC, HiGH iMPACT

for both public and private buildings.

Classification: 3442 Color: RAL9005

EMC radiation from electrical installation

Diameter

Meter

Article

(mm)

coil (m)

Number

16

100

316894

20

100

316895

768 v/m 312 v/m

HALOVOLT EMC SOCkET

29 v/m

Bad installation

Normal installation

Material: Halogen Free

EMC installation

PROTECTiON The Halovolt Low Friction EMC pipe from Pipelife is on the outside recognizably black. This is the protective outer layer. This outer layer facilitates the best possible protection against the electromagnetic radiation that wants to pass through the pipe. This outer layer blocks the EMC radia-

Color: RAL9005 Material: Halogen Free Diameter

Pieces per

Bag per

Article

(mm)

Bag

Package

Number

16

50

400

316898

20

50

400

316899

HALOVOLT EMC BENdS Color: RAL9005 Material: Halogen Free Diameter

Pieces per

Bag per

Article

(mm)

Bag

Package

Number

16

25

150

316902

20

25

125

316903

HALOVOLT EMC CONNECTORS Color: RAL9005

tion, so that no or very little EMC radiation es-

Material: Halogen Free

capes into the living or working environment

Diameter

Pieces per

Bag per

Article

(mm)

Carton

Package

Number

where the pipes are installed. It facilitates the best possible protection and keeps harmful EMC radiation to an absolute minimum.

16

316908

20

316909


PiPELifE wORLd widE

Pipelife European Electro Office Pipelife Office and Plant Pipelife Sales Office

European Electro Office: Pipelife Netherlands B.V. Flevolaan 7 1601 MA Enkhuizen Telephone: +31 (0) 228 355 555 www.pipelife.nl Contact: Mark Bakker

Patrick Verschuur

Sales Manager Electro Export

Product Manager Electro Export

e-mail: mark.bakker@pipelife.nl

e-mail: patrick.verschuur@pipelife.nl

mobile phone: +31 (0) 653 260 977

mobile phone: +31 (0) 646 789 609

NO MORE ELECTRO STRESS


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.