Inspirational external envelopes
ALUMINIUM JOINERY
CLADDING
SUN PROTECTION
SUPPLIERS OF INNOVATIVE EXTERIOR SYSTEMS WITH DISTINCTION
.
Content
REQUIREMENTS JOINERY SOLUTIONS FLASHING SYSTEM UNDERLAY CLADDING SOLUTIONS COMPANY CAPABILITIES STUDY
JOINERY SOLUTIONS
Positioning of CP96: middle range
CP50 Slide Price: 54% Uf:3.4 - 4,9 W/m²K Water tightness: 200Pa
CP96
CP155
Slide/Lift-Slide Price: 100% Uf:3.5 – 6,9 W/m²K Water tightness: 600Pa WK2 certified
Slide/ Lift-Slide Price: 170% Uf:3.0 – 4,8 W/m²K Water tightness: 450Pa WK2 certified
Positioning within CP96: wide range
CP96 mono
CP96
CP96-LS
CP96 mono AP
CP96 AP
CP96-LS AP
FEATURES Wind load testing Water resistance Air tightness Anti burglary available Acoustic testing Corrosion resistance Cyclic testing opening hardware Testing max sizes available?
2nd generation, optimized quality system
Fabricators
 New chicane solution: Better solution for water tightness in co-extruded synthetic profile (1) and integrated detail for brush for better water tightness (2)
2
2 1 1
Architects
Aesthetic solution
Aesthetical straight design: vents are in same plane as the frame. same visual width as CS for T-profiles
Hidden drainage solution optional bicolor optional for complete range
Architects
Aesthetic solution
Wide range of 7mm square pin handles available. 90° corner profile coupling of sliding doors, ideal for veranda applications
90°
Architects
Maximal transparency
Sliding system: glass weight up to 300 kg Lift-slide system:
Light version up to 150 kg
Heavy weight version up to 300 kg
Vent dimensions up to 2m40 height and more than 2m width Glazing up to 30mm for maximal insulation
Architects
Extreme water resistance
New patented solution from Reynaers with water tightness up to 600 pa
Face cap with valve
Separation piece for base profile
Developed for monorail application in high-rise buildings
End-user
Extensive range of safety solutions
Design of the profiles result in a dedicated anti burglary solution Small space between vent and frame protects the lock from burglary attacks WK2 certifications are available for a complete range of configurations except for double sliding LS-version.
End-user
Easy gliding solution
 To obtain minimal friction of the sliding door we optimized the brush.  The glass weight is exactly in line with the position of the wheels. This results in more easy sliding and maximal stability of the vent.
End-user
Good Accessibility, low threshold
 Because of the minimal frame height of 28mm in the lift & slide version, the system can easily be integrated in the floor.
28mm
HARDWARE OPTIONS One design..... For all opening types
3 additional exterior finishes (CS-68 suite)
Soft line
Renaissance
Hidden Vent
Slim line options
HI-FINITY
Option for self-regulating Passive Ventilation
Option to include insect protection
Air tight connection: Reynaconnect
REYNACONNECT
REYNACONNECT
FLASHING SYSTEM
FEATURES NZ 4284 Testing, VM1
Air tightness Flexibility Prepared in factory for perfect fit to windows Sill solution No bitumous components Sill detail sliding door Option: extruded clay for windows ?
Proprietary window jamb flashing accommodates all locations of joinery
FEATURES  Proprietary jamb tray draines any infiltrated water back through the cladding negative detail
UNDERLAY
TEXTILE BUILDING WRAP
Key Objectives: • Addressing the water & air tightness with a monolithic, resilient flexible layer under the cladding • Maintaining vapour openness so moisture vapour is not trapped • Robust system required to seal all penetrations so air tightness is always maintained
The solution:
Ferrari Stamisol FA membrane
Wrap
Clay
-
Completely sealed membrane
-
UV resistant up to 5,000 hrs
-
Stretch of 25%
Fibre cement
Polycarbonate
-
Water resistant up to 600mm
-
Wind resistant up to 2.5 kPa
-
Vapour open
-
Avoid internal condensation
Contact glue system – no perforations except for sealed Systemsbrackets Building wrap -
ACM
-
Installed over 6 mm fibre cement backer board from Very High Wind loading
Stamisol Color as an attractive weathertight backing to open rainscreens
CLADDING OPTIONS
T50 Vertical only rails and fixing Cavity adjustable by 15mm in depth
•
•
Adhesive only and rivet options for panel fixing Allowances for movement with floating points at the junction of all materials
T
T50 • •
T90
T230
Cavity depths of between 50-600mm possible Ideal for incorporating insulation inside the cavity
HIGH DENSITY FIBRE CEMENT Overhead
TECTIVA
Fonterra Building, Fanshawe St (photos during construction)
CLAY TILE CLADDING
•
The original clay cladding tile
•
Made popular by Architect Renzo Piano
•
A durable cladding solution with many possibilities
•
100% natural product
•
Ease of installation
•
Maintenance free
NATURAL CLAY BASE MATERIALS
Shop front Overhead Standard
Standard
DESIGN OPTIONS: Overhead Shop front CLADDING
COMPANY CAPABILITIES
System designers for range of unique exterior building systems
Complete engineered compliant solutions including design, connections, detailing and shop drawings
Products and systems fully tested
Wide range of colour schemes, textures and patterns, free joint patterns, perforations,‌
Direct sourcing from manufacturers. Systems adjusted and tested in NZ
DESIGN
Design includes • Value engineering • Systems and details, BIM capability • Engineering and testing • Customised solutions • Trained by Reynaers • Durability statement • Complete performance review – – – – –
Thermal Structural Acoustic Fixing design Thermal / hygric / carbonation differential stress analysis
EXPERTISE
• • • •
Recognized international suppliers with best-in-class reputation Durability-proven systems Trendsetters Machines from Reynaers Aluminium
INSTALLATION • Certified installers • Trained in installation, quoting and QA
PRODUCER STATEMENTS • PS1 to B1, B2, E2, F2 • E2 when – –
Approved wall underlay or Ferrari wrap is used Approved detailing at openings
THERM
Estimation software Passive House calcs
WINDOW
Structural assessment
U value
STUDY
Study design by experts K.U. Leuven and Bauphi N.V. Building Physics expert on Building Physics simulation of up to 3different wall build-up options Opinion on air leakage and consequences Opinion on system connections
Reynaers Institute Hardware durability Optional: thermal performance
50 mm wide cavity for enhanced safety Fast, flexible and accurate installation Fully engineered economic solution featuring breathable Stamisol Building wrap/membrane to allow moisture vapor to exit wall.
Same wall build up but with vapour closed barrier such as Plywood, with no external insulation: The dew point will be inside the ply layer meaning internal condensation will occur on the frame
Same wall build up as previous slide but 90mm cavity and insulation in the cavity on the outside of the Plywood. This shifts the dew point to the outside of the ply meaning no condensation within the wall.
ACTIVITIES
RESEARCH & DEVELOPMENT EXTRUSIO N
SALES & MARKETING EXTRUSIO N
REYNAERS INSTITUTE: • certification, technical approval • one of the largest private test centres in Europe
AIR-WIND-WATER TESTS
ACOUSTIC TESTS
SUSTAINABILITY
CYCLIC TESTS
AGEING TESTS
SAFETY
BURGLAR RESISTANCE TESTS
IMPACT TESTS
INSULATION EXTRUSIO N
SURFACE TREATMENT EXTRUSIO N
LOGISTICS EXTRUSIO N
Testing
COMFORT
TESTING EXTRUSIO N
AUTOMATIO N & TRAINING EXTRUSIO N
QUALITY CONTROL EXTRUSIO N
ACTIVITIES Testing
RESEARCH & DEVELOPMENT EXTRUSIO N
•
testing of energy performance
•
condensation tests on (ventilated) façades or window systems
•
behaviour of systems in winter/summer
•
tests and demonstrations on building connections
INSULATION EXTRUSIO N
SURFACE TREATMENT EXTRUSIO N
LOGISTICS EXTRUSIO N
SALES & MARKETING EXTRUSIO N
R-CUBE: dedicated labo on location (in-situ testing)
TESTING EXTRUSIO N
AUTOMATIO N & TRAINING EXTRUSIO N
QUALITY CONTROL EXTRUSIO N