Protek Valves

Page 1

CATALOGUE 218

PROTEK MANUFACTURING CORP. ,ŝŐŚ WĞƌĨŽƌŵĂŶĐĞ &ŝƌĞ &ŝŐŚƟŶŐ ƋƵŝƉŵĞŶƚ

R

www.protekfire.com.tw

sales@protekfire.com.tw

0062


VALVES

GATED WYES

Protek offers a wide selection of valves, including wyes, water thief and siamese. Wyes are used to divide a single flow, allowing fire fighters to extend attack lines when pre-connects do not reach. Both 2-way and 3-way wye options are available. Water Thief allows fire fighters to extend attack lines from a main supply line. Siamese is used to combine several hose lines into one. Both dual-inlet and trio-inlet siamese options are available.

Wyes

• • • • •

505

506

Available in lightweight alloy or brass construction Working pressure up to 200 psi (13.79 bar) Easy operation even at high flows Minimal friction loss Used to divide a single flow

Forestry Wye • Male adapters are easily removed for adjustment of seats • 1" female inlet x two 1" male outlets

Forestry Wye • 1-1/2" female inlet x two 1-1/2" male outlets

Style 506

Style 505

Style 520-BC

Style 530

520, 520-BC Leader Line Wye • 2-1/2" female inlet x two 1-1/2" male outlets 530

Leader Line Wye Style 540-BC • Self-locking handle for positive positioning • 2-1/2" female inlet x two Style Material Inlet 1-1/2" male outlets

540, 540-BC Hydrant Wye • 2-1/2" to 6" female inlet x two  2-1/2" male outlets 541

550

587

Hydrant Wye • 2-1/2" female inlet x two  2-1/2" male outlets

3-Way Hydrant Wye • Self-locking handle • 2-1/2" to 6" female inlet x three  2-1/2" male outlets Plain Wye • 2-1/2" to 6" female inlet x two   2-1/2" male outlets

505

Alloy

506

Alloy

520-BC

Brass

540

Alloy

520 530

Alloy Alloy

540-BC

Brass

550

Alloy

541

587

Alloy Alloy

1" F (25mm) 1-1/2" F (38mm) 2-1/2" F (65mm) 2-1/2" F (65mm) 2-1/2" F (65mm) 2-1/2" to 6" F (65-150mm) 2-1/2" to 6" F (65-150mm) 2-1/2" F (65mm) 2-1/2" to 6" F (65-150mm) 2-1/2" F (65mm)

Style 550 Weight Lbs(kg) 1"M (×2) 2.2 (25mm) (1kg) 1" or 1-1/2"M (×2) 2.2 (25 or 38mm) (1kg) 1-1/2"M (×2) 4 (38mm) (1.8kg) 1-1/2"M (×2) 9 (38mm) (4.1kg) 1-1/2"M (×2) 6.4 (38mm) (2.9kg) 2-1/2"M (×2) 14.3 (65mm) (6.4kg) 2-1/2"M (×2) 33 (65mm) (15kg) 2-1/2"M (×2) 8.8 (65mm) (4kg) 2-1/2"M (×3) 20 (65mm) (9.2kg) 2-1/2"M (×2) 3.7 (65mm) (1.7kg) Outlet

WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

63


VALVES

WATER THIEF & SIAMESE

Water Thief • Lightweight alloy • Self-locking handle • Used for laying, extending or adding 1-1/2" or 2-1/2" lines without interfering with operation of other lines • 2-1/2" female inlet x one 2-1/2" and two 1-1/2" male outlets

510

Style 510

Water Thief

Style

Material

Inlet

Outlet

510

Alloy

2-1/2"F (65mm)

1-1/2"M (×2) & 2-1/2"M (×1) (38 & 65mm)

Siamese

Weight Lbs. (kg) 13.5 (6.1kg)

• Available in lightweight alloy or brass construction • Used to combine several hose lines into one • Clappers allow additional lines to be added without interrupting flow

545, 545-BC

585

Suction Siamese • Used as suction inlet collection for pumpers • Self-locking handle • 2-1/2" swivel inlets come with strainers • Two 2-1/2" female inlets x one 2-1/2" to 6" female

Style

Material

545

Alloy

545-BC

Brass

585

Alloy

555

Valves 595

596

Style 545

Clappered Valve Siamese • Two 2-1/2" female inlet x 2-1/2" male outlet • Optional drain valve

Alloy

Inlet

Outlet

2-1/2"F (×2) (65mm) 2-1/2"F (×2) (65mm) 2-1/2"F (×3) (65mm) 2-1/2"F (×2) (65mm)

2-1/2" to 6"F (65-150mm) 2-1/2" to 6"F (65-150mm) 2-1/2" to 6"F (65-150mm) 2-1/2"M (65mm)

Weight Lbs. (kg) 15.8 (7.2kg) 36 (16.5kg) 21.3 (9.7kg) 7 (3.2kg)

Style 555

Style 585

2-1/2" Hydrant Valve Style 596 • Lightweight alloy • 2-1/2" full flow waterway • Self-locking handle for positive positioning • Adapter easily removed for seat adjustment • 2-1/2" female inlet x 2-1/2" male outlet Style Material 2-1/2" Gate Valve • • • • •

Lightweight alloy Wedge seat gate valve Non-rising stem design Crank handle for easier operation 2-1/2" female inlet x 2-1/2" male outlet

595

596

Alloy

Alloy

Style 595 Inlet

Outlet

2-1/2"F (65mm) 2-1/2"F (65mm)

2-1/2"M (65mm) 2-1/2"M (65mm)

Weight Lbs. (kg) 7.3 (3.3kg) 4.6 (2.1kg)

WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

64



TECHNICAL DATA

FLOW & REACH DATA

The flow and reach data provides you with key information on our handline nozzle capabilities. The following table outlines the flow setting and the straight stream reach for our handline nozzles at various pressures. The data is compiled and updated by our Engineering & Testing departments.

Selectable Gallonage Handline Nozzles Style

360 (page 3)

361 (page 3)

362 (page 3)

Nozzle Pressure PSI

BAR

75

5

100

7

125

8.5

75

5

100

7

125

8.5

75

5

100

7

125

8.5

Flow Setting GPM 5 10 24 40 5 10 24 40 5 10 24 40 13 25 40 60 13 25 40 60 13 25 40 60 12 23 30 12 23 30 12 23 30

LPM 19 37 90 150 19 37 90 150 19 37 90 150 50 100 150 230 50 100 150 230 50 100 150 230 50 90 115 50 90 115 50 90 115

Actual Flow GPM 4 9 21 35 5 10 24 40 6 11 27 45 11 22 35 52 13 25 40 60 15 28 45 67 10 20 26 12 23 30 13 26 34

LPM 15 34 79 132 19 37 90 150 22 42 102 170 42 83 132 197 50 100 150 230 57 106 170 254 38 76 98 50 90 115 49 98 129

Straight Stream Reach Effective Overall Feet Meters Feet Meters 45 13 55 16 45 13 55 16 65 19 75 22 75 22 85 26 50 15 60 18 50 15 60 18 70 21 80 24 90 27 100 30 55 16 65 20 55 16 65 20 70 21 80 18 90 29 105 32 50 15 60 18 60 18 70 21 75 22 85 25 95 29 105 32 55 16 65 20 60 18 70 21 90 27 100 30 105 32 115 35 55 16 65 19 65 19 75 23 95 29 105 32 110 34 120 36 50 15 60 18 65 19 75 22 70 21 80 24 55 16 65 19 21 80 24 70 75 22 85 26 60 18 70 21 70 21 80 24 80 24 90 27

Notes Reach figures are measured with nozzle at 32° above horizontal. Overall reach is considered where the furthest droplets of water fall, in still conditions. Effective reach is considered the furthest portion of the water droplet foot print where fire fighting can be accomplished, in still conditions. These tests are conducted in still conditions, so the actual results will vary depending upon conditions.

WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

66


The flow and reach data provides you with key information on our handline nozzle capabilities. The following table outlines the flow setting and the straight stream reach for our handline nozzles at various pressures. The data is compiled and updated by our Engineering & Testing departments.

Selectable Gallonage Handline Nozzles Style

366 (page 4)

Nozzle Pressure PSI

BAR

75

5

100

125

75

367, 368 (page 5-6)

100

125

7

8.5

5

7

8.5

GPM 30

LPM 115

GPM 26

LPM 98

Straight Stream Reach Effective Overall Feet Meters Feet Meters 80 24 90 27

125

475

108

409

130

360

95

Flow Setting

60 95

30

60 95

125

230 360

115

230

Actual Flow

52 82

30

60

197 310

115

230 360

30

110

34

85

26

95

29

120

105 125

40

30 38

140

115 135

42

35 41

107

125

475

108

409

125

38

135

41

250

950

217

821

160

48

170

51

95

125 95

150

200 95

125

150

200

250 95

125

150

200

250

230

475 360

550

750

360

475

550

750

950 360

475

550

750

950

67

140 82

130

173 95

125

150

200

250 106

140

168

224

280

129

90

254

110

310

115

401

530

492

654

360

475

550

750

950 401

530

636

848

1060

125

135

145

155

140

150

160

170

175 115

145

160

175

185

27 34

38

41

35

44

47

42

45

48

51

53 44

47

48

53 56

150

39

360

60

34

42

130

125

115

140

36

475

30

475

100

100 120

130

145

125

155

165

150

160

170

180

185 155

165

170

185

195

TECHNICAL DATA

FLOW & REACH DATA

45

30 36

41

44

38

47

50

45

68

51

54

56 47

50

51

56 59

Notes Reach figures are measured with nozzle at 32° above horizontal. Overall reach is considered where the furthest droplets of water fall, in still conditions. Effective reach is considered the furthest portion of the water droplet foot print where fire fighting can be accomplished, in still conditions. These tests are conducted in still conditions, so the actual results will vary depending upon conditions.

WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

67


TECHNICAL DATA

FLOW & REACH DATA

The flow and reach data provides you with key information on our handline nozzle capabilities. The following table outlines the flow setting and the straight stream reach for our handline nozzles at various pressures. The data is compiled and updated by our Engineering & Testing departments.

Multi-Purpose Handline Nozzles Orifice Size

Nozzle Pressure PSI 50 75 50 75 50 75 50 75 50 75 50 75 50 75

3/8" 1/2" 5/8" 3/4" 7/8" 15/16" 1"

Combination Flows Style

332 (page 9)

Tip Size 3/8"

1/2"

5/8"

333 (page 9)

3/4"

7/8"

15/16" 1"

BAR 3.5 5 3.5 5 3.5 5 3.5 5 3.5 5 3.5 5 3.5 5

Inlet Pressure PSI BAR 50 3.5 75 5 50 3.5 75 5 50 3.5 75 5 50 3.5 75 5 50 3.5 75 5 50 3.5 75 5 50 3.5 75 5

Smooth Bore Flow GPM 23 50 45 60 75 95 108 135 155 190 187 229 216 266

LPM 87 114 170 227 284 360 409 571 587 719 708 867 818 1007

Flow GPM LPM 66 250 78 295 88 333 107 405 108 409 136 515 199 753 247 935 232 878 289 1094 250 946 313 1185 270 1022 334 1264

Straight Stream Reach Effective Overall Feet Meters Feet Meters 55 17 65 20 65 20 75 23 65 20 75 23 85 26 95 29 85 26 95 29 105 32 115 35 105 32 115 35 115 35 125 38 135 41 145 44 155 47 165 50 135 41 145 44 155 47 165 50 140 43 150 46 160 48 170 52

Fog Flows Style

332

333

Inlet Pressure PSI BAR

Flow GPM LPM

50

3.5

42

160

100

7

60

226

70

5

50

3.5

100

7

75

5

52

197

95

360

135

510

118

445

Notes Reach figures are measured with nozzle at 32° above horizontal. Overall reach is considered where the furthest droplets of water fall, in still conditions. Effective reach is considered the furthest portion of the water droplet foot print where fire fighting can be accomplished, in still conditions. These tests are conducted in still conditions, so the actual results will vary depending upon conditions.

WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

68


The flow and reach data provides you with key information on our handline nozzle capabilities. The following table outlines the flow setting and the straight stream reach for our handline nozzles at different pressures. The data is compiled and updated by our Engineering & Testing departments.

Constant Gallonage Handline Nozzles Style

371 (page 15)

Straight Stream Reach Actual Flow 100 psi Effective Overall Flow 75 psi 100 psi 125 psi 75 psi 100 psi 125 psi 75 psi 100 psi 125 psi Setting 5 bar 7 bar 8.5 bar 5 bar 7 bar 8.5 bar 5 bar 7 bar 8.5 bar 13 11 13 15 GPM 55 65 75 65 75 85 50

42

40

35

25

100

60

52

60

254 67

197

230

254

125

108

125

140

95

360

150

550

200

750

250

950

374 (page 16)

230

45

230

475

373 (page 16)

67

197 82

310

409

130

492

173

655

217

821

95

360

475

150

550

200

750

250

821

950

250

300

1140

655

217

260

984

750

300

1140

Meters

GPM

75

85

95

85

95

105

Feet

32

35

LPM

GPM LPM

GPM

168

636

224

848

280

70

21

23

85

26

85

LPM

26

GPM

115

LPM

41

LPM

280

950

750

26

530

401

250

200

23

GPM

1060

173

20

106

950

200

23

LPM

60

150

20

170

52

40

16

GPM

106

LPM

GPM

GPM LPM

GPM LPM

75

23

26

85

26

29

95

105

29

32

29

95

32

105

80

24

26

95

29

38

41

35

38

41

38

135

130 40

150 45

145 44

145 44

160 49

135

160 47

160 49

170 52

115

30

29

100

125

105

32

115

125 38

29

29

105

115 35

26

95

95

90

27

85

125

140 44

140 42

160 49

32

125

135 41

155 47

155 47

170 52

44

165 50

170 52

180

1060

LPM

49

52

56

52

55

59

335

1268

GPM LPM

160

170 52

170

190 58

185

200 61

170

180 55

180

200 61

Meters

Meters Feet

Meters Feet

Meters Feet

Feet

180

GPM

Feet

195

170 52

Feet

Meters

150 45

Meters

55

170 52

Feet

Feet

160 49

Meters

145

135

140 42

Meters

Meters

GPM LPM

Feet

35

224

848

Feet

LPM

28

100

132

230

25

57

83

150 60

372 (page 15)

22

49

55

210 64

TECHNICAL DATA

FLOW & REACH DATA

Feet

Meters

Meters Feet

Meters

Notes Reach figures are measured with nozzle at 32° above horizontal. Overall reach is considered where the furthest droplets of water fall, in still conditions. Effective reach is considered the furthest portion of the water droplet foot print where fire fighting can be accomplished, in still conditions. These tests are conducted in still conditions, so the actual results will vary depending upon conditions. WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

69


TECHNICAL DATA

COMPATIBILITY CHART These charts are designed to help you determine the compatibility of Protek monitors with its wide selection of nozzles and available accessories. It will assist you in choosing the suitable nozzle(s) for your new monitor as well as the accessories that you may like to add in order to broaden the application of your monitor. Monitors Accessories

Combination of Style 911 oscillating flange,and Style 611 monitor and Style 847-BC monitor nozzle

Combination of Style 649 monitor and Style 848-BC monitor nozzle

Industrial Monitors 605 111 611 119 560 699 911 916 612 119 560 699 911 916 633 119 560 699 911 916 636 119 560 699 911 916 648 119 560 699 911 916 649 119 560 699 911 916 655 119 560 699 911 916 736 119 560 699 911 916 Portable Ground Monitors 600-1 119 600-2 119 Portable Dual Purpose Ground Monitors 622-1 119 120 190 699 622-2 119 120 190 699 622-3 119 120 699 Remote Controlled Monitors 922 Electric Valve, Quick Connection Wireless Remote Controlled Monitors 933 Touch Screen Control Panel, Wire or Wireless Joystick Control, Electric Valve 955

Monitors Nozzles (Handline / Monitors / Self-Educting) & Smooth Bore Tips Industrial Monitors 605 106 112 115 366-TO 367-TO 372-TO 373-TO 375-TO 820 611 823-BC 825-BC 830 832 835-BC 845-BC 847-BC 848-BC 887 612 823-BC 825-BC 830 832 835-BC 845-BC 847-BC 848-BC 887 633 823 825 830 832 835 845 847 848 887 636 823-BC 825-BC 832 835-BC 845-BC 847-BC 848-BC 887 888 648 823-BC 825-BC 832 835-BC 845-BC 847-BC 848-BC 887 888 649 823-BC 825-BC 830 832 835-BC 845-BC 847-BC 848-BC 887 655 823 825 830 832 835 845 847 848 887 736 823-BC 825-BC 830 832 835-BC 845-BC 847-BC 848-BC 887 Portable Ground Monitors 600-1 117 118 314-TO 368-TO 375-TO 822 824 600-2 117 118 314-TO 368-TO 375-TO 822 824 Portable Dual Purpose Ground Monitors 622-1 823 825 830 832 835 845 847 848 887 622-2 823 825 830 832 835 845 847 848 887 622-3 823 825 830 832 835 845 847 848 887 Portable Oscillating Ground Monitors 625-1 118 822 824 625-2 118 822 824 Remote Controlled Monitors 922 818E 819E 820E Wireless Remote Controlled Monitors 933 817E 955 855E

888 888 888 889 889 888 888 888

889 889 889 889 889 889

888 888 888

WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

70


This chart is designed to help you better understand the performance of our foam eductors at various operating pressures. It will also help you choose a nozzle that is compatible with your eductor. All of our eductors achieve their rated flow at an inlet pressure of 200 psi. At lower pressures the water flow is less, but the flow of foam concentrate will remain the same. Consequently, the foam solution will be a richer mixture than the metering valve indicates. In addition, at lower pressures (flows) the effective reach of the nozzles decreases. Please take this into account when making your initial attack.

TECHNICAL DATA

EDUCTOR/NOZZLE PERFORMANCE DATA

Foam Eductors

Eductor Recommanded Nozzles Inlet (pages 61-62) For Use With Eductor Pressure 201-60 203-60 222-60

201-95 203-95 222-95

366, 372, 366-BC, 372-BC

366, 367, 368, 369, 372, 366-BC, 372-BC, 373-BC, 374-BC

200

120

100

200

150

100

200

150

100

205-250

366, 367, 368, 369, 372, 366-BC, 372-BC, 373-BC, 374-BC

368, 374, 368-BC, 374-BC

GPM

LPM

60

231

52

42

95

82

67

95

82

197

156

360

310

254

360

310

Maximum Nozzle Effective Hose Lay^ Pressure Reach# (feet) (psi) (feet) 100

100

100

50

65

75

90

100

100

150

50

150

250

100 50

250

254

250

150

108

408

150

200

125

100

125 88

475

333

475

75

85

75

95

75

95

90

75

150

100

100

150

50

75

75

90

300

100

100

300

50

75

150

108

200

250

950

200

100

120

100

177

670

150

50

80

100

150

88

217

408

75

150

67

200

203-125 222-125

Flow Rate*

333

821

300

200

Notes * Total flow when picking up 6% foam concentrate through metering valve. ^ Maximum hose lay from eductor discharge to nozzle. # These figures are with foam solution flowing and the nozzle set on straight stream.

75

75

90

110

WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

71


TECHNICAL DATA

THREAD INFORMATION

These tables outline the most commonly used threads. However, Protek has the ability to cut many other threads required by the fire service. Generally, there is no extra charge for these unique threads. Style 3/4" 1" 1-1/2" 2" 2-1/2" 3" 3-1/2" 4" 4-1/4" 5" 6"

National Standard (NH) ODM TPI 1.375 8 1.375 8 1.99 9 2.515 8 3.068 7.5 3.6239 6 4.2439 6 5.0109 4 5.7609 4 6.26 4 7.025 4

Straight New York New York Pacific Chicago Iron Pipe FD Corp Coast Fire Dept. (NPSH) (FDNY) (NYC) (PCT) (CFD) ODM TPI ODM TPI ODM TPI ODM TPI ODM TPI 1.0353 14 1.0625 11 1.295 11.5 1.66 8 1.3125 11.5 1.8788 11.5 2.1 8 2.093 11 2.1 11 1.933 11.5 2.3528 11.5 2.561 11 2.55 10 2.841 8 3.03 8 3 8 3.046 7.5 2.99 7.5 3.47 8 3.97 8 4.052 8 4.47 8 5.011 4 4.97 8 5.761 4 6.26 4 5.53 8 6.59 8

Canadian Standard 2-1/2" Hose Threads

Code

Description

ODM

TPI

AMA

Albert Mutual Aid

2.99

8

Province of Quebec Standard

3.031

BCT CSA QST WCT NDC

British Columbia

3

Canadian Standards Association - Ontario 3.125 Western Canada Fire Underwriters Nova Scotia - Zones 1 2-1/2" ANSI 150#

Outside Diameter Thickness Bolt Hole Circle Number of Bolts Size of Bolts

7"

0.75" 5.5" 4

5/8"

3.25

3.234

8 5

7

6

5

5/8"

8

5/8"

4.45 4.95 5.45 6.45

ABBREVIATION DEFINITIONS ODM – outside diameter of male TPI – threads per inch

11 11 11 11

THREAD DESIGNATIONS National Hose – NH or NHT; also called National Standard Thread (NST) National Pipe Straight Hose – NPSH; also called Straight Iron Pipe Thread (SIPT) National Pipe Thread – NPT; also called Tapered Iron Pipe Thread (TIPT) British Standard Parallel Pipe – BSPP British Standard Pipe Taper – BSP

Flange Specifications 3" ANSI 150# 4" ANSI 150# DN80 PN20 DN100 PN20 7.5" 9" 190.5mm 230mm 0.75" 0.94" 20mm 23mm 6" 7.5" 152.5mm 190.5mm 4

British Standard (BSP) ODM TPI 1.041 14 1.309 11 1.882 11 2.347 11 2.96 11 3.46 11

DN80 PN16

DN100 PN16

200mm

220mm

160mm

180mm

16mm

16mm

22mm 8

22mm 8

Please contact us on support@protekfire.com.tw to check availability of a specific thread on your product. WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

72


Liquid Volume Into Multiply By Mililiters (ml) 29.57 Liters (l) 0.4732 Liters (l) 0.9464 Liters (l) 3.785 Ounces (oz) 0.0338 Pints (pt) 2.113 Quarts (qt) 1.057 Gallons (gal) 0.2642 Solid Volume - Weight To Convert Into Multiply By Ounces (oz) Grams (g) 28.3495 Pounds (lb) Kilograms (kg) 0.4536 Grams (g) Ounces (oz) 0.035 Kilograms (kg) Pounds (lb) 2.205 Pressure To Convert Into Multiply By Pounds per Square inch (psi) Kilopascals (kPa) 6.895 Pounds per Square inch (psi) bar 0.06895 Kilopascals (kPa) Pounds per Square inch (psi) 0.145 Kilopascals (kPa) bar 0.01 bar Pounds per Square inch (psi) 14.503 bar Kilopascals (kPa) 100 Length To Convert Into Multiply By inches (in) Milimeters (mm) 25.4 inches (in) Centimeters (cm) 2.54 Feet (ft) Centimeters (cm) 30.48 Yards (yd) Meters (m) 0.914 Miles (mi) Kilometers (km) 1.609 Milimeters (mm) inches (in) 0.039 Centimeters (cm) inches (in) 0.394 Meters (m) Yards (yd) 0.094 Kilometers (km) Miles (mi) 0.6214 Area To Convert Into Multiply By Square inches (sq in) Square Centimeters (cm²) 6.425 Square feet (sq ft) Square Meters (m²) 0.093 Square Yards (sq yd) Square Meters (m²) 0.836 Square Miles (sq mi) Square Kilometers (km²) 2.59 Square Centimeters (cm²) Square inches (sq in) 0.155 Square Meters (m²) Square feet (sq ft) 1.196 Square Kilometers (km²) Square Yards (sq yd) 0.386 Pressures  50 psi = 345 kPa =  3.45 bar 300 psi = 2069 kPa = 20.69 bar  60 psi = 414 kPa =   4.14 bar 350 psi = 2413 kPa = 24.13 bar  70 psi = 488 kPa =  4.88 bar 400 psi = 2758 kPa = 27.58 bar  75 psi = 517 kPa =   5.17 bar 450 psi = 3103 kPa = 31.03 bar  80 psi =  552 kPa =  5.52 bar 500 psi = 3448 kPa = 34.48 bar  90 psi =  621 kPa =  6.21 bar 550 psi = 3792 kPa = 37.92 bar 100 psi =   690 kPa =     6.9 bar 600 psi = 4137 kPa = 41.37 bar 150 psi = 1034 kPa = 10.34 bar 650 psi = 4482 kPa = 44.82 bar 200 psi = 1379 kPa = 13.79 bar 700 psi = 4827 kPa = 48.27 bar 250 psi = 1723 kPa = 17.23 bar

To Convert Ounces (oz) Pints (pt) Quarts (qt) Gallons (gal) Mililiters (ml) Liters (l) Liters (l) Liters (l)

3/4" Tip   7/8" Tip  1" Tip 1-1/8" Tip 1-1/4" Tip 1-3/8" Tip

1" Hose  1.5" Hose 1.75" Hose 2" Hose   2.5" Hose  3" Hose 3.5" Hose 12 gpm 13 gpm 20 gpm 23 gpm 25 gpm 30 gpm 40 gpm 50 gpm 55 gpm 60 gpm 70 gpm 75 gpm 85 gpm 95 gpm   100 gpm   120 gpm   125 gpm   150 gpm   175 gpm   200 gpm   250 gpm   300 gpm   350 gpm   375 gpm   400 gpm   450 gpm   500 gpm   700 gpm   750 gpm   800 gpm 1000 gpm 1200 gpm 1250 gpm 1500 gpm 2000 gpm

Tip Sizes 19 mm   1-1/2" Tip 22 mm   1-3/4" Tip 25 mm  2" Tip 28 mm 2-1/4" Tip 32 mm 2-1/2" Tip 35 mm 3" Tip Hose Sizes = 25.4 mm  4" Storz = = 38.1 mm  4" Storz = = 44.5 mm 4.5" Storz = = 63.5 mm  5" Storz = = 63.5 mm  5" Storz = = 76.2 mm  6" Storz = = 88.9 mm Flow Rate = 45.42 lpm = = 49.20 lpm = = 75.70 lpm = = 87.06 lpm = = 94.62 lpm = =   113.55 lpm = =   151.40 lpm = =   189.25 lpm = =   208.18 lpm = =   227.10 lpm = =   264.95 lpm = =   283.88 lpm = =   321.73 lpm = =   359.58 lpm = =   378.50 lpm = =   454.20 lpm = =   473.13 lpm = =   567.75 lpm = =   662.38 lpm = =   757.00 lpm = =   946.25 lpm = = 1135.50 lpm = = 1324.75 lpm = = 1419.38 lpm = = 1514.00 lpm = = 1703.25 lpm = = 1892.50 lpm = = 2649.50 lpm = = 2838.75 lpm = = 3028.00 lpm = = 3785.00 lpm = = 4542.00 lpm = = 4731.25 lpm = = 5677.50 lpm = = 7570.00 lpm = = = = = = =

= = = = = =

38 mm 45 mm 50 mm 57 mm 64 mm 76 mm

TECHNICAL DATA

METRIC CONVERSION

100mm 101.60mm 114.30mm 125.00mm 127.00mm 152.40mm 45 lpm 50 lpm 75 lpm 90 lpm 95 lpm    115 lpm    150 lpm    190 lpm    210 lpm    230 lpm    265 lpm    285 lpm    320 lpm    360 lpm    380 lpm    460 lpm    475 lpm    550 lpm    660 lpm    750 lpm    950 lpm    1140 lpm    1325 lpm    1420 lpm    1525 lpm    1700 lpm    1900 lpm    2660 lpm    2900 lpm    3030 lpm 3800 lpm 4500 lpm 4800 lpm 6000 lpm 7600 lpm

WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

73


TECHNICAL DATA

STYLE NUMBER INDEX

Style 100 101 101-BC 102 102-BC 103 104 105 106 111 112 115 117 118 119 119-BC 120 129 130 130-BC 132 133 135 137 139 150 155 162 176 178 182 190 191 201-60 201-95 203-60 203-95 203-125 204

Page 25 25 25 25 26 26 18 27 27 29 27 27 27 27 46 46 27 29 26 26 26 29 29 29 29 29 28 28 28 28 28 55 29 61 61 61 61 61 22

Style 205-250 210 211 212 213 214 215 216 217 218 219 221 222-60 222-95 222-125 225 226 227 236 238 277 279 280 302 303 304 305 306 307 308-3 308-6 309 310 311 312 314 314-TP 320 321

Page 62 24 24 24 24 24 24 24 24 24 24 46 62 62 62 24 24 24 21 22 23 23 23 19 19 19 19 19 31 35 35 31 11 11 11 11 11 34 12

Style 322 322-SP 323 323-DP 324 324-TP 332 333 360 360-TO 360-BA 360-BC 361 362 366 366-TO 366-BA 366-BC 366-BC 366-BCSP 366-BI 367 367-TO 367-BA 367-BC 367-BI 368 368-TO 368-BA 368-BC 368-BCTO 368-BCTP 368-BI 368-TP 369 369-TO 369-BA 370 371

Page 12 12 13 13 13 13 9 9 3 3 3 3 3 3 4 4 4 4 32 32 4 5 5 5 5 5 6 6 6 6 6 6 6 6 5 5 5 4 15

Style 372 372-TO 372-BA 372-BC 372-BC 373 373-TO 373-BA 373-BC 374 374-BC 374-BC 374-TP 374-BCTP 375 375-TO 379 382 385 386 387-BC 388-BC 392 505 506 510 520 520-BC 530 540 540-BC 541 545 545-BC 550 555 560 585 587

Page 15 15 15 15 32 16 16 16 16 16 16 32 17 17 17 17 34 33 33 33 20 20 34 63 63 64 63 63 63 63 63 63 64 64 63 64 58 64 63

Style 595 596 600-1 600-2 605 611 612 622-1 622-2 622-3 625-1 625-2 633 636 648 649 655 699 736 814 817E 818 818E 818-BC 819 819E 819-BC 820 820-BC 820E 822 822-BC 823 823-BC 824 824-BC 825 825-BC 830

Page 64 64 53 53 48 49 49 54 54 55 56 56 52 50 50 51 52 58 51 35 43 39 43 39 39 43 39 39 39 43 40 40 40 40 40 40 42 42 41

Style 832 833 835 835-BC 837-BC 845 845-BC 846 846-BC 847 847-BC 848 848-BC 849 849-BC 855E 881-BC 883-BC 886 886-BC 887 887-BC 888 888-BC 889 889-BC 911 916 918 922 933 955 2360 2361 2365 2366 2368 2368-TP

Page 41 41 42 42 42 40 40 37 37 37 37 37 37 37 37 43 44 44 45 45 45 45 45 45 46 46 57 57 57 59 60 60 7 7 7 7 7 7

WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

74


LIMITED WARRANTY Protek Manufacturing Corp., 64 Kan Su Road, Section #2, Taichung, Taiwan (“Warrantor”) warrants to the original purchaser of the new fire protection equipment manufactured by Warrantor, and to anyone to whom it is transferred, that the equipment shall be free from defects in material and workmanship during the five (5) year period (electrical components two [2] years) commencing upon the receipt of such equipment by the original purchaser. Warrantor’s obligation under this warranty is specifically limited to replacing or repairing its equipment or parts which are shown by Warrantor’s examination to be in a defective condition attributable to Warrantor. To qualify for this limited warranty, the claimant must return the equipment to Warrantor, at its above address, transportation charges prepaid, within a reasonable time after discovery of an alleged defect. Warrantor will examine the equipment. If Warrantor determines that there is a defect attributable to it, Warrantor will correct the problem within a reasonable time. If the equipment is covered by this limited warranty, Warrantor will assume the expenses of repair, except for transportation charges and shipping expenses incurred in delivering such equipment to Warrantor.

If any defect attributable to Warrantor under this limited warranty cannot be reasonably cured by repair or replacement, Warrantor may elect to refund the purchase price of the equipment, less reasonable depreciation, in complete discharge of its obligations under this limited warranty. If Warrantor makes this election, the claimant shall return the equipment to Warrantor free and clear of any liens and encumbrances.

This is a limited warranty. The original purchaser of the equipment, any person to whom it is transferred, and any person who is an intended or unintended beneficiary of the equipment, shall not be entitled to recover from Warrantor any consequential or incidental damages for injury to person and/or property resulting from any defective equipment manufactured or assembled by Warrantor. Warrantor shall have no obligation under this limited warranty if the equipment is, or has been, misused or neglected (including failure to provide reasonable maintenance) or if there have been accidents to the equipment or if it has been repaired or altered by someone else.

THIS IS A LIMITED EXPRESS WARRANTY ONLY. WARRANTOR EXPRESSLY DISCLAIMS WITH RESPECT TO THE EQUIPMENT ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. THERE IS NO WARRANTY OF ANY NATURE MADE BY WARRANTOR BEYOND THAT STATED IN THE DOCUMENT. Warrantor reserves the right to change the parts or design of its products from time to time without notice, and with no obligation to maintain spare parts or to make corresponding changes in the products previously manufactured. Protek is proud to be ISO 9001:2008 registered with the internationally recognised Underwriter Laboratories Inc. (UL) and CE marking with Bureau Veritas S.A.

WƌŽƚĞŬ DĂŶƵĨĂĐƚƵƌŝŶŐ ŽƌƉ͘ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

WARRANTY

WARRANTY


PROTEK MANUFACTURING CORP.

,ŝŐŚ WĞƌĨŽƌŵĂŶĐĞ &ŝƌĞ &ŝŐŚƟŶŐ ƋƵŝƉŵĞŶƚ

,ĂŶĚůŝŶĞ EŽnjnjůĞƐ ^ĞůĞĐƚĂďůĞ͕ DƵůƟͲWƵƌƉŽƐĞ͕ ƵƚŽŵĂƟĐ͕ ŽŶƐƚĂŶƚ ,ŝŐŚ WƌĞƐƐƵƌĞ ĂŶĚ ^ŚŽĐŬůĞƐƐ EŽnjnjůĞƐ ^ĞůĨͲ ĚƵĐƟŶŐ EŽnjnjůĞƐ ĂŶĚ &ŽĂŵ EŽnjnjůĞƐ Ăůů ^ŚƵƚŽīƐ͕ WůĂLJƉŝƉĞƐ ĂŶĚ ^ŵŽŽƚŚ ŽƌĞ dŝƉƐ EŽnjnjůĞ ĂƐĞ͕ dĞĞƚŚ͕ ,ĂŶĚůĞƐ ĂŶĚ ĐĐĞƐƐŽƌŝĞƐ

^ƉĞĐŝĂůŝƚLJ EŽnjnjůĞƐ tŝůĚůĂŶĚͬ&ŽƌĞƐƚƌLJ͕ DĂƌŝŶĞ͕ &ůĂƐŚŽǀĞƌ͕ ůĞĐƚƌŝĐ͕ ĞŝĐŝŶŐ WŝĞƌĐŝŶŐ ƉƉůŝĐĂƚŽƌƐ ĂŶĚ /ŶĚƵƐƚƌŝĂů &ŽŐ EŽnjnjůĞ

DŽŶŝƚŽƌ EŽnjnjůĞƐ ^ĞůĞĐƚĂďůĞ͕ ĚũƵƐƚĂďůĞ &ůŽǁͲ ĂŋĞ͕ ƵƚŽŵĂƟĐ͕ ŽŶƐƚĂŶƚ ůĞĐƚƌŝĐĂůůLJ ŽŶƚƌŽůůĞĚ DŽŶŝƚŽƌ EŽnjnjůĞƐ ^ĞůĨͲ ĚƵĐƟŶŐ DŽŶŝƚŽƌ EŽnjnjůĞƐ DŽŶŝƚŽƌ EŽnjnjůĞ ĐĐĞƐƐŽƌŝĞƐ

DŽŶŝƚŽƌƐ /ŶĚƵƐƚƌŝĂů͕ WŽƌƚĂďůĞ͕ ƵĂůͲWƵƌƉŽƐĞ͕ WŽƌƚĂďůĞ KƐĐŝůůĂƟŶŐ ZĞŵŽƚĞ ŽŶƚƌŽůůĞĚ ĂŶĚ tŝƌĞůĞƐƐ ZĞŵŽƚĞ ŽŶƚƌŽůůĞĚ DŽŶŝƚŽƌ ĐĐĞƐƐŽƌŝĞƐ

&ŽĂŵ ƋƵŝƉŵĞŶƚ ^ĞůĨͲ ĚƵĐƟŶŐ ,ĂŶĚůŝŶĞ ĂŶĚ DŽŶŝƚŽƌ EŽnjnjůĞƐ ƵĂůͲ&ůŽǁ &ŽĂŵ͕ ƵĂůͲ ŐĞŶƚ͕ ƌLJ ŚĞŵŝĐĂů EŽnjnjůĞƐ &ŽĂŵ ĞƌĂƟŽŶ dƵďĞƐ /ŶͲ>ŝŶĞ ĂŶĚ WŽƌƚĂďůĞ LJͲWĂƐƐ ĚƵĐƚŽƌƐ

sĂůǀĞƐ tLJĞƐ tĂƚĞƌ dŚŝĞĨ ^ŝĂŵĞƐĞ sĂůǀĞƐ

,ĞĂĚƋƵĂƌƚĞƌ Θ DĂŶƵĨĂĐƚƵƌŝŶŐ &ĂĐŝůŝƟĞƐ

/ŶƚĞƌŶĂƟŽŶĂů ^ĂůĞƐ KĸĐĞ

ϲϰ <ĂŶ ^Ƶ ZŽĂĚ͕ ^ĞĐ͘ Ϯ͕ yŝƚƵŶ ŝƐƚ͕͘ dĂŝĐŚƵŶŐ ϰϬϳ dĂŝǁĂŶ DĂŝůŝŶŐ ĚĚƌĞƐƐ͗ WK Ždž ϮϳͲϭϮϲ͕ dĂŝĐŚƵŶŐ dĂŝǁĂŶ ǁǁǁ͘ƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ

WK Ždž ϳϬϳ͕ ĂůǁLJŶ EŽƌƚŚ͕ sŝĐƚŽƌŝĂ ϯϭϬϰ ƵƐƚƌĂůŝĂ DŽďŝůĞ͗ нϲϭͲϰϬϬͲϴϴϴͲϲϯϵ &Ădž͗ нϲϭͲϯͲϵϴϱϵͲϭϭϮϮ ŵĂŝů͗ ƐĂůĞƐΛƉƌŽƚĞŬĮƌĞ͘ĐŽŵ͘ƚǁ ^ŬLJƉĞ͗ ƉƌŽƚĞŬƐĂůĞƐ


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.