10 minute read
Fire Safety
by PSI Media
Fire safety in schools
Understanding the UK requirements for fire safety in schools can be challenging. Will Lloyd and Neil Budd, technical managers at the Fire Industry Association, explains what schools need to know
There are over 32,000 schools throughout the UK. Analysis of Home Office data by leading insurer Zurich Municipal shows that in the period from 2015 to 2020, schools in England had experienced 2,300 fires of which 47 school buildings were destroyed. This has a significant impact on not only the local community, but also individual pupils. Keeping both teachers, pupils, and the school buildings safe from fire is of utmost importance.
Requirements
Understanding the UK requirements for fire safety in schools can be challenging. Fire safety starts with the design of the building and Building Bulletin 100: Design for fire safety in schools (BB 100) is the starting point, alongside Approved Document B (ADB) volume 2, to establish a good foundation of fire safety.
BB 100 was recently the subject of a government consultation to seek views on a revised version. Some of the questions asked during the consultation included: views on which fire suppression systems (including sprinkler, misting systems etc.) are most effective in a school environment; whether BB 100 should include advice on specific property protection measures; and whether BB 100 should provide greater guidance on meeting fire safety management long-term, to support users to meet the requirements of the Regulatory Reform (Fire Safety) Order 2005.
The consultation on the new revision of BB 100 closed on the 18th of August 2021. The Government has issued a response to the consultation, but the revised guidance has yet to be published.
Approved Document part B is the baseline guidance for fire safety in buildings, and the recommendations of part B will typically be satisfied where the life safety guidance of BB 100 is followed.
Fire doors
One key fire safety element of the building’s construction is the presence of fire doors. Fire doors are used to prevent fire and smoke from spreading to protected routes i.e. protected corridors and stairways. They can also be used to restrict disproportionate damage to the school, as a result of a fire by acting as means of compartmentation, thus limiting the spread of a fire. Therefore, it is fundamental that these vital fire safety measures are subject to a suitable system of inspection and maintenance, as required by the Regulatory Reform (Fire Safety) Order 2005.
As fire doors are one of the key elements of fire safety in a school (and other buildings), it is essential that where they need to be held open, in order to allow the free movement of students, teachers and visitors around the school, they are not “wedged” open, but rather a suitable alternative method is adopted. This could be in the form of electronic hold-open devices that are linked to the automatic fire detection and fire alarm system so that they release upon detection of fire. BS 7273-4 is the appropriate British Standard for the interconnection of a fire detection and fire alarm systems and electronic hold-open devices, and anyone employed to install and maintain these devices should be competent. One of the easiest ways of ensuring competence is by the use of third-party certified companies.
Many schools, for security purposes, will implement an access control system to restrict access to authorised people. Where these systems are adopted on doors that form part of the means of escape, under BS 7273-4, BB 100 and Approved Document B, these doors should release upon detection of a fire.
Raising the alarm
All schools should have suitable arrangements for raising the alarm to warn occupants in the event of a fire. A fire detection and fire alarm system, installed to BS 5839-1 by a third-party certified company, provides confidence that a fire situation will be detected at the appropriate time E
The millions of period products being flushed every year is leading to blocked sewers, damage to buildings, polluted beaches and environmental damage, and this needs to change.
At phs, as hygiene specialists, we’re in a brilliantly unique position to help convert flushers into binners and we are committed to help do that from as early as possible, starting at school.
We recently commissioned a behavioural science whitepaper, Water Pollution – Less flushing, more discussing and we discovered that the right behaviour is more complicated than just having the knowledge not to flush. Sadly, many of us are flushing as a result of period shame not just ignorance.
More than half of tampon users throw them down the toilet every single day of their period rather than binning them.
Our research has shown that the reasons behind flushing is rooted in shame; with two in five (41%) of us feeling the need to hide our periods, and a quarter are flushing tampons are choosing to do so because it’s ‘less embarrassing’.
We’re eager to share what we’ve learned with schools, including the behavioural and practical recommendations that can make a difference in communicating with learners, educating those who have periods early to establish binning habits as soon as possible.
A part of this is talking to each other – all of us; and normalising the conversation around periods between friends and family, employers and employees and most importantly – between teachers and learners.
The whitepaper also revealed the environment and facilities people experience can also influence their behaviour. In shared spaces like public bathrooms at schools, those who flush tampons are most likely to do so if there is no bin in the bathroom (59%), no bin in the cubicle (57%), or when the bin is full (54%).
But how can we change things? It’s imperative that we continue to break down the barriers and stigma around periods. Nobody should be feeling shame or embarrassment about a monthly bodily function in 2022.
Every school, college and university can make a significant positive contribution to stopping the environmental pollution caused by flushing period products.
We urge schools to continue the brilliant work already taking place in tackling stigma around period equality. Our mission is to support educators to completely eradicate the culture of whispering around periods; to have open conversations about binning products and identify the improvements that work best for their school, their learners and the environment.
If you want to learn more about what schools can do to instigate flushing behaviours search “phs Water Pollution – Less flushing, more discussing” to read our whitepaper, or get in touch with us.
to allow sufficient opportunity for evacuation of all persons from the affected building(s). The size and complexity of the fire detection and fire alarm system will be proportionate to the size and complexity of the school. For example, a small school on one storey with no more than 160 pupils may only require a manual system with no automatic detection. Whereas a large multi-storey school with multiple buildings may require automatic detection throughout the buildings and possibly the installation of a voice alarm system complying with BS 58398, which may also incorporate a public address system, which will provide both an audible signal and verbal instructions in case of fire.
Many schools are implementing a means to warn occupants of a security situation within the school grounds, whereby there is a need to keep students within designated areas in the building. This is commonly known as lockdown and more recently known as invacuation. The FIA has produced a guidance note on these systems1 .
With increased awareness of people with sensory sensitivities, the FIA created a Special Interest Group (SIG) to discuss the needs of those people who may not react in the manner that the specifiers and designers of the fire detection and fire alarm system may expect. The guidance document2 that the FIA have subsequently published is intended to highlight the issue and provide guidance, not only for schools, but for the wider fire safety community.
Dual approach
With arson (wilful fire raising) being one of the main causes of fire in education establishments, the need to not only protect people’s lives in the school, but also the need to protect property (e.g. the IT equipment, education resources and the buildings themselves) leads to a dual approach to tailor the fire safety measures to the location, use and risks identified. The use of sprinklers for property protection is one of the main mitigating factors that can be implemented within a new school building, and even installed retrospectively to existing buildings to protect the property. A fire detection and fire alarm system which satisfies both the property protection objective and the life safety objective, and which includes automatic transmission of alarm signals to a monitored alarm receiving centre (ARC) to summon the fire and rescue service, will assist in early attendance without the need for a telephone call. It is advised that where possible, an automatic signal to the ARC is backed up by a telephone call to the fire and rescue service to provide confirmation of a real fire event. The ARC connection is particularly important with regards to property protection at night when the school is not occupied. The fire detection and fire alarm system needs to be designed and maintained to ensure that false alarms do not occur, however in practice, this is extremely difficult. Schools may be subject to malicious false alarms and a badly designed system could lead to false alarms from environmental influences. These create disruption to the school day, and where the fire and rescue service attends, wastes valuable time and could be taking resources away from a real fire situation elsewhere. The FIA has further guidance on how Premises Management can help to limit false alarms in their buildings https://www.fia.uk.com/cut-false-alarm-costs.html.
The FIA will be holding a series of regional events in 2023 with a specific focus on fire safety in schools. Signing up to the FIA email newsletter will keep you informed of all the events FIA taking place. L
FURTHER INFORMATION
www.fia.uk.com
1. FIA guidance note: Use of fire alarm systems for lockdown (specifically in schools) 2. FIA guidance document: Fire alarm considerations for people with sensory sensitivities Manchester Metropolitan University’s Story: Why are schools switching to Tio for Education – the digital fire safety software that makes compliance simple, smart, and automated
Manchester Met digitalised its fire compliance records using Tio for Education for the 22/23 academic year and beyond in minutes - this is their story.
Manchester Met is one of the UK’s largest universities with over 40,000 students enrolled every year, but it has struggled with keeping all 36 paper fire logbooks updated and in good repair for years given the continuous development happening on campus – a challenge every school can relate to.
With the new legislation and a better understanding of the requirements, Amanda Lane, Principal Fire Safety Manager at Manchester Met, knew something had to change and Tio for Education was the solution.
Amanda set up a Tio for Education account in minutes and had her staff documenting fire safety checks via the Tio app in just a few days. Manchester Met now have all their most important building documents uploaded to the Tio Cloud and staff update each building’s new digital fire logbook by simply scanning the QR codes on the walls.
With the free built-in Tio how-to guides, Manchester Met staff follow step-by-step instructions on how to complete every check with confidence. They receive clear daily, weekly, and monthly guidance on minimising incidences of fire like ensuring that fire detection and protection systems are maintained. This ensures every test is done correctly, comprehensively, and is recorded accurately.
Schools have thousands of students depending on every safety issue being resolved - Tio’s automatic notification system enables you to keep everyone on top of tasks and responsibilities.
Tio for Education supports single location schools & academies with multiple buildings and campuses by empowering managers to monitor the school’s fire safety compliance from a single allencompassing online dashboard.
Join the growing number of Universities, Schools, and Academies like Manchester Met, Dean Close School and Dartmoor Academy Trust who are using Tio for Education. L Tio’s mission is to make fire safety in education simpler, smarter, and manageable for only £30/building/year.
FURTHER INFORMATION