HFW-100 T6 Powered by:
IVECO NEF45 TM2 97 kW at 60 Hz
Generating Set Performance
60 Hz
SERVICE
Rated output Active power output * Rated speed Standard Voltage Voltage available
kVA kW
Continuous Service
Intermittent Service
110 88
121 97 1.800 480 220 / 208 / 440 / 416
r.p.m. V V
Performance data refers to Standard Reference Conditions of ISO 8528 : + 25 °C , 100 m ALT, relative humidity 30 % During running-in period the output increases by approx. 5 % which is taken into consideration at delivery. Power reduction acc. to DIN ISO 3046. Standard values: Above 100 m ALT approx. 1 % per 100 m. Above 25 °C (77 °F) approx. 4 % per 10 °C (50 °F). * Considering cos phi= 0,8
Prime Mover Performance
1.800 r.p.m. Continuous Service
SERVICE
Rated output Manufacturer Engine model 4 stroke Diesel Engine - Injection type Aspiration type Cylinders, number and arrangement Bore x stroke Total displacement Cooling system Lube oil specifications Specific fuel consumption Specific oil consumption (at full load) Compression ratio Lube oil maximum capacity Lube oil minimum capacity Speed governor Air filter
kW
mm - In L
g/kWh Kg/cm2 L L Type Type
Intermittent Service
97
107
IVECO MOTORS NEF45 TM2 DIRECT TURBOCHARGED 4-L 104 x 132 4,5 WATER ACEA E3 - E5 221 <0,1% max. of fuel consumption 17,5 : 1 electronic DRY light duty
PRIME POWER (P.R.P.): The prime power is the maximum power available with varyng loads for an unlimited number of hours. The average power output during a 24h period of operation must no exceed 80% of the dechared prime power between the prescribed maintenance intervals and at standard environmental conditions. A 10% overload is permissible for 1 hour every 12 hours of operation. STAND BY POWER: Is the maximum power available for a period of 500 hours/year with a mean load factor of 90% of the declared stand-by power. No kind of overload is permissible for this use.
Synchronous Generator * Pôles Winding connections (standard) Frame mounting Insulation Enclosure (according to IEC-34-5) Phases Voltage regulator Steady voltage precision
4
Nº
class
Star - serie SAE 3 - 11 1/2 H IP 23 3+N A.V.R. (electronic) within ± 1,5% from no load to full loading with cosf=0,8÷1
*Alternator used by HIMOINSA Gensets meet the requirements of following Standard: IEC 34-1; CEI 2-3; ; VDE 0530; BS 4999-5000:NF 51-100,11
HFW100 T6 - 97 kW at 60 Hz
Generating Set Installation Data
1.800 r.p.m.
EXHAUST SYSTEM Max. exhaust temperature at full load Exhaust gas flow Heat rejected to exhaust Maximum allowed back pressure AIR REQUIREMENT Air requirement for combustion at 100% load / rated speed
ºC ºF Kg/h Kcal/Kwh kPa(mbar)
m3/min kg/ h
540 1004 N.D. 785,3 6 (60) 734 609,3
ELECTRIC STARTING SYSTEM kW
Starting motor output
CV
Minimum recommended battery capacity Auxiliary voltage LIQUID CAPACITY Lube oil system including sump, filters, etc.
3 4,08
Vcc.
1 X 100 12
L
12,8
Open Skid Genset
LL LL
150
Soundproofed
Ah
FUEL TANK CAPACITY
165
Generating Set transport data
Pub. I005 HFW-100 T6 06/2006 - Himoinsa reserves the right to modify any characteristic without prior notice. Weights and dimensions based on products standars and sec / Ilustration may include optional equipment.
WEIGHT AND DIMENSIONS OPEN SKID GENSET Length Width Height Shipping volume seaworthy (Standard supplier) Dry weight (with standard accessories)
m - ft m - ft m - ft m3 - ft3 kg - lb
2,0 0,7 1,4 2,27 1.125
-
6,72 2,46 4,85 80,17 2.475 *
WEIGHT AND DIMENSIONS SOUNDPROOFED GENSET Length Width Height Shipping volume seaworthy (Standard supplier) Dry weight (with standard accessories)
m - ft m - ft m - ft m3 - ft3 kg - lb
2,75 - 9,02 1,1 - 3,60 1,50 - 4,92 4,53 - 159,76 1.670 - 3.674 *
* The weights are approximate