Forman - Data Sheet Pink Batts

Page 1

THERMAL INSULATION

Pink® Batts® Ceiling Application ®

®

PRODUCT DATA SHEET

Pink Batts ceiling insulation is a light weight flexible glass wool insulation product designed to: Thermally insulate ceilings in new homes, be retrofitted into existing homes with no insulation or over existing insulation for better performance Fit easily into standard ceiling constructions, or be easily cut to fit in non standard constructions Meet the requirements of the New Zealand Building Code (NZBC) for different designs and environments

Features and Benefits BRANZ appraised, a durable product for 50 years as required by the NZBC 1 Energy saving – a well insulated home can save up to $1800 on energy bills annually Non-combustible, will not burn for a safer environment R-values up to R5.0, to assist in keeping homes above 18ºC, as per the World Health Organisations recommendation for a healthy and comfortable home Absorbs sound for a quieter more relaxing home 1

(Department of Building and Housing, Your guide to a smarter home, 2008, p. 28)

Environment Manufactured using up to 80% recycled glass, making sustainable use of waste ® ® Energy used during the manufacture of Pink Batts products, is offset by the energy saved by ® ® 2 a home fully insulated with Pink Batts products within 3-15 months Locally manufactured in Auckland and Christchurch, minimising shipping distances compared to imported products Potential Green Star NZ Credits ® ® Green Star NZ is a comprehensive environmental rating system for buildings. Pink Batts insulation may contribute the following points under Green Star Office Design V.1: EMI-8

One point

MAT-11

One point

Thermal insulation avoids the use of ozone depleting substances in both manufacture and composition. 90% or more of the thermal insulation used is certified through a recognised a body (e.g., NZ Environmental Choice) as having lower environmental impact.

Certification and further information is available at www.nzgbc.org.nz Environmental Choice ® ® Higher R-value Pink Batts Ceiling insulation products have Environmental Choice New Zealand Accreditation (refer to the product specifications) - Independently assessed for: Waste Minimisation: Recycled content, and recycling of process waste Energy Management: Effective energy management policies and procedures Manufacturing Process: Not manufactured using blowing agents with a global warming potential Product Characteristics: Durability and performance

While only the higher R-value products are eligible for Environmental Choice, all Pink® Batts® Thermal Insulation Products are manufactured in the same environmentally considerate way

1235revA Oct08 Page Page 1 1 of of 6 6

2

(Beca Carter Hollings & Ferner ltd, Energy Economics of Fibreglass Insulation, 2005)

www.pinkbatts.co.nz This data sheet may have been superseded. Please refer to www.pinkbatts.co.nz or call 0800 PINK BATTS (746 522) for the most current information


THERMAL INSULATION

Pink® Batts® Ceiling Health

General Health ® ® Pink Batts insulation will assist in meeting the World Health Organisation recommendation for houses to be maintained at a minimum temperature of 18ºC to provide a healthy and comfortable home ® ® Pink Batts insulation has been accepted into the Asthma and Respiratory Foundation of New Zealand’s Sensitive Choice programme. Insulating with ® ® Pink Batts is beneficial to those suffering from asthma A Wellington School of Medicine study found insulated houses resulted in families with fewer sick days and the economic benefit was double the initial 3 cost of the insulation 3

(Howden-Chapman, P. et al. "Effect of insulating existing houses on health inequality: cluster randomised study in the community" British Medical Journal, 2007, p334:460)

Technical Data Properties

Result

Combustibility

Non-Combustible

Flammability

Non-Flammable

Test Method/Standard 

NZS/AS 1530.1:1994 NZS/AS 1530.3:1993 Ignitability (Range 0-20) Spread of Flame Index (Range 0-10) Heat Evolved Index (Range 0-10) Smoke Developed Index (Range (0-10)

Various*

Non-Corrosive

N/A

AS/NZS 4859.1:2002-Glasswool exempt

Moisture Absorption

Non-Hygroscopic

N/A

AS/NZS 4859.1:2002-Glasswool exempt

Vermin Resistance

No Food Source

AS/NZS 4859.1:2002-Glasswool exempt

R-value Corrosion

Test Results

PRODUCT DATA SHEET

Product Safety ® ® Pink Batts insulation is a non hazardous, safe product IARC (International Agency for Research on Cancer) classifies glass wool ® ® formulation used to manufacture Pink Batts products as Group 3: ‘Not classifiable as to its carcinogenicity to humans’ This the same classification as caffeine, tea, hair colouring, chlorinated drinking water, saccharin ® ® Pink Batts insulation is bio-soluble. In the unlikely event any fibres are inhaled into the lungs they will dissolve in the body fluids and be cleared from the body

=0 =0 =0 = 0-1

AS/NZS 4859.1:2002

*Refer to product specifications

Acoustic Properties ®

®

Pink Batts insulation will assist with noise control, however penetrations in walls will transmit sound ® ® readily. Superior noise control can be achieved by using Pink Batts insulation products in conjunction with good acoustic design.

Page 2 of 6

www.pinkbatts.co.nz This data sheet may have been superseded. Please refer to www.pinkbatts.co.nz or call 0800 PINK BATTS (746 522) for the most current information


THERMAL INSULATION

Pink® Batts® Ceiling

PRODUCT DATA SHEET

New Zealand Building Code (NZBC) and Limitations ®

®

®

®

®

®

Pink Batts ceiling insulation when used, installed and maintained in accordance with the requirements outlined in this datasheet, will meet or contribute to meeting the following provisions of the NZBC: NZBC Clause B2: Durability Meets the requirement NZBC B2.3.1 a) 50 years and NZBC B2.3.1 b) 15 years NZBC Clause E2: External Moisture Contributes to meeting these requirements NZBC Clause E3: Internal Moisture Contributes to meeting these requirements NZBC Clause F2: Hazardous Building Materials Meets this requirement and will not present a health hazard to people Limitations To meet the provisions of the NZBC as outlined in this datasheet, Pink Batts ceiling insulation must be: Installed and maintained in a dry protected environment Installed in a building where the provisions of NZBC E2 and E3 are met Installed to the requirements of NZS 4246:2006:Energy Efficiency-Installing Insulation in Residential Buildings Pink Batts ceiling insulation should not be: Crushed or folded Exposed to moisture for prolonged periods of time

Ceiling Installation Instructions ®

®

Correct installation with no compression, gaps or folds is critical to ensure Pink Batts ceiling insulation performance is not compromised Tools : Knife and cutting board Lamp and extension cord (15m long) Install rod (25mm rod, 1m long) for tight spaces Protective loose fitting, long sleeved clothing Dust mask Gloves Safety goggles Planks (long enough to span across joists) Safety

1235revA Oct08 Page Page 3 3 of of 6 6

Beware of loose boards and pipe work when working in the ceiling. Use planks laid across joists to walk on Ensure there is adequate lighting During daytime, avoid times of excessive heat, the ceiling cavity can get very hot Be careful not to cut or bare cables and wires Beware of other sharp objects, nails, splinters etc Beware of pests such as bees and wasps

www.pinkbatts.co.nz This data sheet may have been superseded. Please refer to www.pinkbatts.co.nz or call 0800 PINK BATTS (746 522) for the most current information


THERMAL INSULATION

Skillion Roof

Pitched Roof

Ceiling Installation Instructions continued… Ensure the product is installed dry. If the product is wet, replace it before installing Use planks laid across joists to walk and work on Any existing insulation should be levelled, refitted if required, and any damp insulation removed Start installation at point furthest away from ceiling manhole If cutting is required, cut oversize by 5-10mm to ensure a friction fit Insulate around vents (not over them) to allow unhindered ventilation Insulate directly up to bricked chimneys leaving no gaps ® ® Fit Pink Batts insulation beneath electrical wiring and plumbing (see caution overleaf) Install to the outer edge of the top plate ® ® Maintain a 25mm gap clearance between the Pink Batts insulation and roof underlay, if required trim insulation to maintain 25mm clearance. (Please consult your designer as to the best method for maintaining good insulation performance and the mandatory 25mm clearance for the particular design and construction of your house)

PRODUCT DATA SHEET

Pink® Batts® Ceiling

Page 4 of 6

www.pinkbatts.co.nz This data sheet may have been superseded. Please refer to www.pinkbatts.co.nz or call 0800 PINK BATTS (746 522) for the most current information


THERMAL INSULATION

Pink® Batts® Ceiling Ceiling Installation Instructions continued… Adhere to the clearances below for recessed light fittings, clearances are required for some fittings to prevent light fittings from overheating and failing Light Fitting Type

Unclassified Halogen CA, RA and OA CS, RS and OS C*, R*, O*, FR and AR

Clearance 200mm 50mm 200mm No clearance required 100mm As specified by manufacturer

Recessed Light Clearances

PRODUCT DATA SHEET

Unknown Light Unclassified Incandescent

®

®

Note: Pink Batts ceiling insulation can be installed from below when the ceiling is to be lined or replaced Caution: Electrical cables and equipment partially or completely surrounded with bulk thermal insulation may overheat and fail. This applies to wiring installed prior to 1989

®

PinkFit Installation Service Installation is critical in ensuring this product performs well. A small gap around the insulation can significantly reduce the construction R-value ®

1235revA Oct08 Page Page 5 5 of of 6 6

PinkFit installers are: A network of licensed professionals across New Zealand Trained installers and guarantee installation to NZS 4246:2006 Call 0800 PINKFIT ® ® ® The preferred Pink Batts installers, and provide a PinkFit guarantee 0800 746 534 certificate

www.pinkbatts.co.nz This data sheet may have been superseded. Please refer to www.pinkbatts.co.nz or call 0800 PINK BATTS (746 522) for the most current information


THERMAL INSULATION

Pink® Batts® Ceiling Specification Notes State the following: Product Required:

Pink Batts Ceiling insulation and required R-value

Installation Service:

PinkFit Installation Service and PinkFit Guarantee Certificate

®

®

®

®

®Batts®

Nominal Thickness (mm)

Size (mm)

Pieces per Pack

Coverage per Pack (m2)*

Area per Pack (m2)

1.8

95

1220 x 432

26

14.4

13.7

R2.2 Ceiling

7110122

2.2

115

1220 x 432

24

13.3

12.6

Pink ®Batts® R2.6 Ceiling

7110126

2.6

140

1220 x 432

20

11.1

10.5

Pink ®Batts® R3.2 Ceiling

7110132

3.2

170

1220 x 432

16

8.8

8.4

Pink

®Batts®

R3.6 Ceiling

7110136

3.6

180

1220 x 432

14

7.7

7.4

Pink

®Batts®

Ultra™ R 4.0 Ceiling

7110140

4.0

190

1220 x 432

12

6.6

6.3

Pink ®Batts® Ultra™ R4.6 Ceiling

7110146

4.6

195

1220 x 432

10

5.5

5.3

Pink ®Batts® Ultra™ R5.0 Ceiling

7110150

5.0

200

1220 x 432

8

4.4

4.2

2.2

94

610 x 432

24

7.0

6.3

Pink

®Batts®

Handy Pack

7110522

* Coverage relates to standard structure and actual coverage may vary.

PRODUCT DATA SHEET

R-value (m2·ºC/W)

Pink ®Batts® R1.8 Ceiling

Environmental Choice

7110118

Product Code

Product

Pink

BRANZ Appraised

Product Specifications

Storage ®

®

Pink Batts insulation must be protected from damage and weather. Store under cover in clean, dry conditions

Accreditations/Appraisals/Certifications

Tasman Insulation New Zealand Limited 9-15 Holloway Place, Penrose, Auckland, New Zealand

Tasman Insulation New Zealand Ltd Certified QMS

(1) This data sheet may have been superseded. Please refer to www.pinkbatts.co.nz for the most current information. This datasheet supersedes all previous versions. (2) Tasman Insulation New Zealand Ltd retains the right to change specifications without prior notification. (3) Do not use this product for any application not detailed in this data sheet. (4) Recommendations and advice regarding the use of this product are to be taken as a guide only. The purchaser should ascertain the suitability of this product for the particular end-use situation intended and when used in conjunction with other products. (5) Consult Tasman Insulation New Zealand Ltd for further information. (6) All claims about this product are subject to any variation caused by normal manufacturing process and tolerances. (7) The liability of Tasman Insulation New Zealand Ltd and its employees and agents for any errors or omissions in this data sheet or otherwise in relation to the product is limited to the fullest extent permitted by law. Except where the consumer acquires the goods for the purposes of a business, any rights a consumer may have under the Consumer Guarantees Act are not affected. (8) This information is provided without prejudice to Tasman Insulation New Zealand Ltd standard terms and conditions of sale.

Please consider the environment before printing this document

For further information visit www.pinkbatts.co.nz or call 0800 PINK BATTS (746 522)

1001 rev B Nov 08 Page 6 of 6


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.