Retrotouch crystal rocker light switch ib b

Page 1

INSTALLATION

10AX LIGHT SWITCHES 1 WAY, 2 WAY, INTERMEDIATE, PULSE

SAFETY WARNING

Before use please read carefully and use in accordance with these safety instructions. Before commencing any electrical work ensure the supply is switched OFF at the mains. Either by switching off the consumer unit or by removing the appropriate fuse. This product should be installed in accordance with the relevant sections of the building regulations code and in accordance with the latest edition of IEE regulations (BS 7671). If the unit is to be used as a replacement for an existing product, remove the existing unit from its location and disconnect the wiring. Connect the wires as shown in diagram. Ensure terminals are properly tightened and ensure no bare wires are visible. When pushing back into the backbox ensure no wires are trapped. Read the instructions carefully before starting the installation process and keep them safe for future reference. IF IN ANY DOUBT, PLEASE CONTACT A QUALIFIED ELECTRICIAN.

WARNING

Do not exceed the load rating as shown on the back of the product Retrotouch (UK) Ltd, Suite 1 Kelvin House, Kelvin Way, Crawley, West Sussex, RH10 9SE. Tel: + 44 (0) 1293 279426 Fax: +44 (0) 1293 471444 email: info@retrotouch.co.uk

IMPORTANT: PLEASE READ ALL THE SAFETY WARNINGS BEFORE COMMENCING ANY WORK. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.

Remove trim cover to access fixing holes by inserting a flat headed screw driver into the aperture on the under side of the switch and twist to remove. Take care and attention not to damage the glass with the screwdriver. Remove the fixing screws (2) from the bag supplied. Undo the terminal screws until they no longer obstruct the cable entry holes. Trim wires to correct length allow cable to reach terminals comfortably. Strip back the insulation (plastic sheath) on the cable to approx 7 to 8mm. Caution: An earth wire must be fitted if a metal mounting box is used. If mounted into a plastic mounting box the earth lead must be fully insulated to prevent earth wire touching live parts or a push-in earth terminal. Connect the wires to the correct terminals according to the marking on the back of the product and wiring diagram. When replacing a switch, take note of the wire positions and terminal markings on the old switch. Carefully push the wired unit back into the mounting box, ensuring the cables are not trapped or pinched. Fit and tighten the fixing screws as supplied. Do not over tighten the screws as it may cause damage to the front plate or the mounting box threads.

REMOVING THE GLASS COVER To remove trim cover insert a flat headed screw driver into the aperture on the under side of the switch (as shown) and twist to remove.

MOUNTING BOX 10A 1 or 2 Way 1,2,3 Gang (25mm back box) 10A 1 or 2 Way 4 Gang, Intermediate, Retractive (35mm back box)

SPECIFICATION Rated Voltage: 250V ~ Rated Current: 10AX Dimension: 86 x 86 mm

Technical queries should be made to Retrotouch Technical Sales and Service Department Tel: +44 (0) 1293 279426 email: support@retrotouch.co.uk Products certified in accordance with BS EN60669 standard.

1

Twist to remove

2


ONE/TWO WAY 10AX SWITCH

INTERMEDIATE 10AX SWITCH

INTERMEDIATE LINK WIRES REQUIRED

One way is used to control one light (circuit) from one switch position only. Two way is used to control one light from two seperate two way switches.

Intermediate is used to control one light from three or more switches and should be used with two way switches as shown in wiring diagram below.

1 Gang model: Add a link wires between L12 to L21 and L22 to L11

Please follow the wiring diagram below and ensure the safety warning and installation guide are read and followed before commencing any work.

Please follow the wiring diagram to the right for the switches and ensure the safety warning and installation guide are read and followed before commencing any work.

2 Gang model: Add a link wires between L12 to L21 , L22 to L11, L32 to L41 & L42 to L31

L1

2 Way Switching

1

L N

1

1

L

L

N

N

L2

L1

L

L1

N

L2

L1

Common

Common

L2

L2

L2

L1

L1

L1

L2

L2

L1 switch

L2

switch

switch

L1 switch

L2

L1 switch

L2

switch

L11

L1

3

COM2

Common Common

Two-way Intermediate Two-way L1 L2 L1 L2 Two-way Intermediate Intermediate Two-way Two-way Two-way L2 switch L1 L2 switch L1 switch

SW.L SW.L SW.L N N NL LL L1

L2

4

1 GANG

Common L1

Common Common

Common Common

Common Common

Common Common

L12

Two-wayTwo-way plus intermediate switchingswitching 3 wire control plus intermediate 3 wire control

Common

Common

L N

Two-way plus intermediate switching 3 wire control

2 Way Switching 2 Way Switching

1 Way Switching 1 Way Switching

L2

L1

2 GANG

L2

L12

L22

COM2

BSEN60669 9

hing

IN

D0202 COM1 10AX250V~

OUT

L22 L32

BSEN60669 9

COM4

L2

L42

10AX250V~ 1 AX25

D0202 D0 0202

L11

L21

L2

L1

5

COM1

L2

L21 L31

COM3 C

L41

L1 L2

L1


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.