HydroC-MEG_ENG

Page 1

HydroC™/ MEG MEG Sensor Mono Ethylene Glycol is one of the most important fluids in the modern Oil + Gas industry. Indeed, in many areas of the offshore, the monitoring of MEG has become a necessity. CONTROS’ HydroC™ / MEG is a unique underwater leakage sensor solving the global problems of the in-situ measurements of Mono Ethylene Glycol. Applications include offshore pipeline inspections, leakage detection, water & waste water treatment tasks and risk management solutions. HydroC™ / MEG - Sensor for Mono Ethylene Glycol (Anti-freeze) in water Function principle

MEG diffuses out of the liquid through a special silicone membrane (patented) into the detector chamber. Inside the chamber MEG gas is measured electronically with an adaptive analysing system and converts into the output signals. Patent pending.

Membrane

Standard: 10 µm silicone membrane. Other options or anti fouling device on request

Operational depth

2000 m, 4000m, 6000m

Temperature

-5°C… +50 °C, other ranges on request

Measuring range

0…100% MEG, other ranges on request

Resolution

0.1 %

Accuracy

±3% reading + 1.5% full scale range (one year max.)

Response time

typ. 20 seconds, T90 time typ. 45 seconds

Zero adjust

Offset zeroing offline with software

ADC

24 Bit AD Converter with DSP Controller

Power supply

Wide range 10 .. 30 VDC typ. 250 mA @ 12V (max. 3,5 W)

Connector

Connector SUBCONN® MCBH8MTI 8-pin

Analogue Output

0 ... 5 V sensor reading

Digital Output

RS-232C, RS-485, CONTROS Long-Range-Modem up to 25 km

Housing

90 d x 380 mm Titanium, other on request (1.4571, POM)

Weight

3.8 kg / 1.8 kg approx. in air / water

Memory, Datalogger

Option internal SmartDI Datalogger with 2 GB CompactFlash Memory RS-232, RS-495 Output Binary and ASCII / NMEA-0183 Format KP30.244 Raw data voltage signal for MEG (MEG exposure 14:28:00 to 14:46:00) 2.7 2.65 2.6 2.55 V

Raw MEG voltage

Signal of a Mono Ethylene Glycol umbilical leakage in seawater at 36 PSU, +8°C, 142m detected with a work ROV.

2.5 2.45 2.4

14:58:20

14:56:20

14:54:20

14:52:20

14:50:20

14:48:20

14:46:20

14:43:20

14:41:20

14:39:20

14:37:20

14:35:01

14:33:00

14:31:00

14:29:00

14:27:00

14:25:00

14:23:09

14:20:40

14:18:40

14:16:40

14:14:40

14:12:00

14:10:04

14:08:00

14:06:00

14:04:00

14:02:00

2.35 14:00:00

Spider ROV on pipeline survey © Statoil/Norsk Hydro

Time/UTC

Symphotic TII Corporation 880 Calle Plano, Unit K Camarillo, CA 93012 Tel: 805-484-6639 www.symphotic.com

Roper Resources Ltd. 984 St. Patrick Street Victoria, BC V8S 4X5 Tel: 805-798-0277 www.roperresources.com

© CONTROS Systems & Solutions GmbH 2007. All rights reserved. In view of our policy of continual improvement, the design and specifications of our products may vary from those illustrated in this brochure. All pictures and trademarks mentioned in this user manual are property of their respective owners. HydroC is the trademark of CONTROS Systems & Solutions GmbH in Germany. SmartDI and CONTROS are the applied trademarks of CONTROS Systems & Solutions GmbH. 15.06.2007


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.