Access Control Accessories

Page 1


TABLE OF CONTENTS

GEM

About GEM

1

Electromagnetic Lock

2

Shear Lock

26

Electric Dropbolt

29

Electric Strike

33

Electromechanical Lock

42

Automatic Door Operator

44

RFID Access Control System

46

Digital Keypad

50

Proximity Card & Key Tag

53

Power Supply Unit

55

Wireless Exit Button

58

Request to Exit

61

Call Point

68

Door Holder

70

Key Switch

72

Accessories

75

GEM

GIANNI INDUSTRIES,INC.

http://gianni.tw/

+886-2-2267-7986

info@gianni.com.tw



A



4



i ng

Ins w

12

4







!

53

0

late 53

0 35 .5 55

53

5

0

29 63 29

6.

.5




DC








!




!








DL-200 Door Loop



Electric Strike Dual Voltage (ANSI)

Features Max. latch throw: 15mm 12/24 VDC Fail-safe/secure changeable Suitable for inswing doors Compatible with mechanical locksets Mortise mount CSIRO fire-resistance certificate GK300-1224 / GK310-1224

GK301-1224 / GK311-1224

Optional Accessory

Specification

Lip extension brackets for the wide jamb

GK300-1224 Operating voltage: 12/24VDC Current draw: 250mA/12VDC 150mA/24VDC Latch width up to 45mm Mortise mount For hollow metal frame doors Compatible with spring latch locksets Remark:

Dimensions Unit: mm 45.5 33

43.5

18

202 45

45

GK310-1224 Latch width up to 36mm LP-050

LP-025

GK301-1224 Operating voltage: 12/24VDC Current draw: 250mA/12VDC 150mA/24VDC Latch width up to 45mm Mortise mount For wooden frame doors Compatible with spring latch locksets Remark:

Application For wide jamb

12

4

17

3

36.5

31.8

GK300-1224

GK301-1224 45.5

33

43.5

GK311-1224 Latch width up to 36mm 18

201

.6

36

36

123

.8

Version Changeable

2

2

3

1

“Fail-Secure” (Power to Open)

34

17 31.75

36.5

1

“Fail-Safe” (Power to Lock)

GK310-1224

GK311-1224


Electric Strike Single Voltage (ANSI)

GK300 / GK310

GK300M / GK310M

GK301 / GK311

Features

Specification

Max. latch throw: 15mm 12 or 24VDC Fail-safe/secure changeable Suitable for inswing doors Compatible with mechanical locksets Mortise mount Switch sensor output

GK300 Operating voltage: 12 or 24VDC Current draw: 250mA/12VDC 150mA/24VDC Latch width up to 45mm Mortise mount For hollow metal frame doors Compatible with spring latch locksets Remark:

Optional Accessory

GK310 Latch width up to 36mm

Lip extension brackets for the wide jamb

GK300M GK310M Latch monitoring switch

GK301M / GK311M

Dimensions Unit: mm 45.5 33

40

18

202 45 1 2

GK301 Operating voltage: 12 or 24VDC Current draw: 250mA/12VDC 150mA/24VDC Mortise mount For wooden frame doors Remark:

17

LP-025

36.5

3

GK300 / GK300M

GK301 / GK301M 45.5

33

GK311 Latch width up to 36mm LP-050

4

43.5

GK301M GK311M Latch monitoring switch

18

201

.6

36

Application

3 6 12 3.8

Version Changeable

For wide jamb 2

2

1

“Fail-Secure” (Power to Open)

1

“Fail-Safe” (Power to Lock)

17

3

31.75

GK310 / GK310M

36.5

GK311 / GK311M

35




Electric Strike GK320 ANSI Series

Features Max. 19mm latch throw 12 VDC, 24 VDC, 12/24 VDC Tvjubcmf!gps!jotxjoh!eppst Compatible with mechanical locksets Mortise mount Accessories for wide jamb: LP-GK320-25/50 GK320

GK321

Optional Accessory

Specification

Lip extension brackets for the wide jamb

GK320 Operating voltage: 12VDC or 24VDC GK320-1224 Operating voltage: 12/24VDC Current draw: 250mA/12VDC 150mA/24VDC Mortise mount Max. latch throw: 19mm (3/4”) For inswing doors Faceplate: short faceplate Door frame: hollow metal frame

LP-GK320-050

LP-GK320-025

Version Changeable

2

2

GK321 Operating voltage: 12VDC or 24VDC GK321-1224 Operating voltage: 12/24VDC Current draw: 250mA/12VDC 150mA/24VDC Mortise mount Max. latch throw: 19mm (3/4”) For inswing doors Faceplate: long faceplate Door frame: wooden frame

Dimensions Unit: mm

41

4 3 .5

18

20

3 6 12

21 3

3 1 .7 5

GK320

1

“Fail-Secure” (Power to Open)

1

“Fail-Safe” (Power to Lock)

Application For wide jamb

38

3.8

3

36.5

GK321

1.6





+


MEG

GE M

MEG

GE M


2

1 3

2

5

4

GEM

6

4

In-swing

7

9

1

3

8

(O

utd

oo

r)

.5 x. 4 Ma

13 14

ter me 0~

7m ete r


Request To Exit The request-to-exit buttons are used in secure door egress and door access control. The buttons are activated by placing your hand or finger on the button on the faceplate. The faceplates come in three sizes, including ANSI, British, and narrow. The buttons come with more different symbols.

Piezo-electric exit button

61


Request to exit Touch Sensitive Series

BTS-115-ANSI

BTS-200

BTS-300

Operating voltage :12~24 VDC Com,N/O,N/C dry contact Relay strike time:1~30 seconds SPDT relay rating:3A/24VDC

Operating voltage :12 VDC Com,N/O,N/C dry contact Relay strike time:1~30 seconds SPDT relay rating:3A/24VDC

Operating voltage :12~24 VDC Com,N/O,N/C dry contact Relay strike time:1~30 seconds SPDT relay rating:3A/24VDC 6*2 levels of LED indicator Press / Touch

BTS-400-ANSI

BTS-85UK

BTS-100

Operating voltage :12~24 VDC Com,N/O,N/C dry contact Relay strike time:1~30 seconds SPDT relay rating:3A/24VDC 6*2 levels of LED indicator Press / Touch

Operating voltage :12~24 VDC Com,N/O,N/C dry contact Relay strike time:1~30 seconds SPDT relay rating:3A/24VDC

Operating voltage :12~24 VDC Com,N/O,N/C dry contact Relay strike time:1~30 seconds SPDT relay rating:3A/24VDC Surface mount

Optioanl Accessory: (Electrical Box)

BTS-486 Operating voltage :12~24 VDC Com,N/O,N/C dry contact Relay strike time:1~30 seconds SPDT relay rating:3A/24VDC 6*2 levels of LED indicator Press / Touch

62

SMB-750

SMB-86ALU-03


Request to exit Press Series

ANSI size 1

2 1

2

AS-1135

AS-1138

AS-1141

Double pole double throw Switch: 1 SWH-260-GE 2 SWH-261-GE

Double pole double throw Switch: 1 SWH-260-GE 2 SWH-261-GE

Single pole single throw Optional letter color: blue or red Switch:SWH-CN020

1

2

1

2

AS-1144

AS-1149

AS-1153

Double pole double throw Optional letter color: blue or red Switch: 1 SWH-1922 2 SWH-1925 With cables

Double pole double throw Optional letter color: blue or red Switch:SWH-060 With cables

Double pole double throw Faceplate: 1 or 2

1

1

1

2

2

2

AS-1156

AS-1157

AS-1158

Double pole double throw Optional letter color: blue or red Switch: 1 SWH-160-GE 2 SWH-160-RE

Double pole double throw Optional letter color: blue or red Switch: 1 SWH-190-GE 2 SWH-190-RE

Double pole double throw Optional letter color: blue or red Switch: 1 S-SI-PBT-GE 2 S-SI-PBT-RE

63


Request to exit Press Series

Stainless steel ANSI size

Stainless steel European size

PBT-020B-4

PBT-160B

PBT-425BS

Double pole double throw Switch: SWH-040 With cables

Double pole double throw Switch: SWH-160-GE

Single pole single throw Switch:MSW-2502-K-EXIT Optional surface mount box

PBT-400BS

PBT-430BS

PBT-861BS-B

Double pole double throw Switch:SWH-160-GE Optional surface mount box

Double pole double throw Switch:SWH-050 With cables Optional surface mount box

Double pole double throw

Surface mount

PBT-450BS

PBS-86G

PBT-025JS

Double pole double throw Switch:SWH-250-GE Optional surface mount box

Plastic surface mount box for british standard press to exit buttons

Single pole single throw Relay rating:5mA/12VDC Aluminum alloy faceplate Switch:MSW-1902-EXIT

64


Request to exit Switch Surface mount

PBT-170

PBT-900-1

Double pole double throw Relay rating:5A/125VAC Stainless steel back box Switch:SWH-160-GE

Single pole double throw Relay rating:15A/125 or 250VAC Stainless steel faceplate

Backlight (LED)

PBT-010L

PBT-020-LED

PBT-419PTE-LED

Double pole double throw LED +/- contact Relay rating:5A/250VAC 6A/24VDC LED operating voltage:6~12VDC Stainless steel faceplate Switch:S-SI-PBT-RE

Single pole single throw LED +/- contact Relay rating:3A/125VAC 6A/24VDC LED operating voltage:12VDC Stainless steel faceplate Switch:S-SI-PBT-100-LED

Single pole single throw LED +/- contact Relay rating:3A/125 VAC 6A/24VDC LED operating voltage:12VDC Europe size mortise mount Switch:S-SI-PBT-100-LED

Piezo-electric exit button

PBT-200LED

PBT-120-PTE

PBT-110-PTE

Double pole double throw LED +/- contact Relay rating:5A/250VAC LED operating voltage:12VDC Stainless steel casing Switch:S-SI-PBT-LED

Input Voltage: 12~24 VDC Current Draw: 80mA/12VDC 40mA/24VDC Max. Time Delay: 1 to 30 secs Beeper sounds Bi-color LED indicator (Green/Red) Relay output contact (COM.,N.O., N.C.) Surface mount

Input Voltage: 12~24 VDC Current Draw: 80mA/12VDC 40mA/24VDC Max. Time Delay: 1 to 30 secs Beeper sounds Bi-color LED indicator (Green/Red) Relay output contact (COM.,N.O., N.C.) Surface mount

65


Request to exit Switch

SWH-10400

SWH-10500

SWH-10405CB

Single pole double throw Relay rating:1.5A/250VAC 1A/125~250VAC Cable : 4 meters Rectangular faceplate

Single pole double throw Relay rating:1.5A/250VAC 1A/125~250VAC Cable : 4 meters Oval-shaped faceplate

Position bolt Single pole double throw Relay rating: 5A/250VAC M18 X P1.0mm Cable : 4 Meters Rectangular stainless steel faceplate

SWH-10505CB

SWH-10415

Position bolt Single pole double throw SPDT (COM,N/C,N/O) M18 X P1.0mm Cable : 4 Meters Oval-shaped stainless steel faceplate

Single pole double throw Relay rating:1.5A/250VAC 1A/125~250VAC Cable : 15 cm Rectangular faceplate With cables

66


Request to exit Micro Switch Bar

EXIT Power Supply Unit

Electromagnet Lock

Door Loop

Access control unit (US) Signal appliance (cUL) PBA-860TDI Micro-Switch Push Bar Time Delay

it Key S Switch

PBA-860

PBA-860 TDI

SPDT switch Anodized finish Switch rating: 5A/125VAC Optional color:red,green,silver

Delayed egress locking systems Operating voltage:12 or 24VDC Switch rating: 5A/125VAC SPDT switch Signal input for emergency Buzzer signal output: 95db Relay strike time:1~30 sec.

Application The switch bar is easy to install and specifically designed to prevent unauthorized access of exit doors and risk of theft and burglary in airports, hotels, and other large-scale doors found in public places. It can also be used in hospitals, nursing homes or rehabilitation centers to prevent unauthorized exit.

Pushing..

The built-in time delay (relocking time) module provides high security for exit door control.

Alarming

After the exit bar is pushed, the switch will activate the buzzer.

After delay time

When the time delay is up, the exit door will be unlocked for egression.

(Reset)

The security guard can reset the switch bar back to normal status with a key.

67


Call Point The Call Point can be activated without power supply in emergencies. It is typically located on fire escape doors. The main function is to override the electrical locking devices in case of emergency. Using the provided key to reset the unit to normal mode and to replace the glass.

E DOMER OR GE RE NC LE Y AS E

BR EA KG LA PR SS ES SH ER E

Bottom Key Hole

68

E DOMER OR GE RE NC LE Y AS E

BR EA KG LA PR SS ES SH ER E

Side Key Hole


Call Point

CP-15 series (Break Glass Unit)

CP-20 series (Break Glass Unit)

CP-21 series (Break Glass Unit)

CP-15-GE

CP-20G

CP-21-GE

Switch rating: 3A/125VAC Dimensions: 88*88*52mm Single pole (N.O./N.C.)

Switch rating: 3A/125VAC Dimensions: 88*88*52mm Double pole (N.O./N.C.)

Switch rating: 3A/125VAC Dimensions: 88*88*52mm Double pole (N.O./N.C.) Color: green,red,white,yellow,blue (yellow is available by special order)

CP-21 series (Backlight):

CP-21-UC

CP-21-GL

CP-21G-L

Protective cover

Glass

Switch rating: 1A/125VAC Dimensions:87*87*55mm 2 Double pole (N.O./N.C.) Color: green,red,yellow (yellow is available by special order)

CP-22 series (Resetable Switch)

CP-24 series

CP-24 series (Backlight)

CP-22-GE

CP-24R

CP-24R-L

Switch rating: 3A/125VAC Dimensions: 88*88*60mm Double pole (N.O./N.C.) Color: green,red,white,yellow (yellow is available by special order)

Switch rating: 1A/125VAC Dimensions:87*87*55mm Quadruple pole (N.O./N.C.) Color: green,red,white,yellow (yellow is available by special order)

Switch rating: 1A/125VAC Dimensions:87*87*55mm Quadruple pole (N.O./N.C.) Color: green,red,white,yellow (yellow is available by special order)

69


Electromagnetic Door Holder Electromagnetic Door Holders are a fail-safe device. They release the fire door when the fire fighting system detects a fire and cuts off the power supply. The closed door may thus prevent the smoke from spreading and moving out of the confined space. The door can also be closed manually by pressing on the release button of the door holders.

Mount Brack & Door Type

Fire Sensor Control Panel

Door Operator

Door Holder

12 VDC (or 24 VDC) are the usual power source used in the control panel.

70

The control panel activates the fire alarm when a fire is detected.

The control panel cuts off the power source.

The electromagnet door holder automatically releases the armature plate allowing the door to close to prevent the fire and smoke from spreading to another room.


Electromagnetic Door Holder

GD650S

GD870S

GD830F

Operating voltage:24VDC (12VDC is available by special order) Holding force:70 lbs Mortise mount European size faceplate

Operating voltage:24VDC (12VDC is available by special order) Holding force:80 lbs Surface mount Release button Anti-residual magnetism kick-off button

Operating voltage:24VDC (12VDC is available by special order) Holding force:80 lbs Floor mount Release button Anti-residual magnetism kick-off button

GD830S

GD900F

GD900W

Operating voltage:24VDC (12VDC is available by special order) Holding force:80 lbs Surface mount Release button Anti-residual magnetism kick-off button

Operating voltage:24VAC/DC (12VAC/DC is available by special order) Holding force:80 lbs Floor mount Release button Anti-residual magnetism kick-off button Remark:

Operating voltage:24VAC/DC (12VAC/DC is available by special order) Holding force:up to 80 lbs Surface mount ANSI Sized faceplate With SMB-050 back box for surface mount (GD900WS) Remark:

RM80 Operating voltage:24VDC (12VDC is available by special order) Holding Force:520 lbs

71


Key Switch Key Switches are installed in secure locations outside, in parallel or series connection with the power supply and the electromagnetic lock. If the electromagnetic lock cannot be opened due to failure of proximity reader or other incidents, the user can use a key to switch between normally closed (N.C.) and normally open (N.O.) contacts, forcing the door to open. Key Switches act as a backup to access control systems.

Maintained SPDT

Momentary SPDT

N.O. Com.

N.O. Com.

N.C.

N.C.

Com.

Com.

72

N.O. Com.

N.C.

N.C.

Maintained DPDT

Com.

Com. N.C.

N.O.

N.O.

N.O. Com.

N.C.

N.O. Com.

N.C.

N.C.

Momentary DPDT

N.O.

N.O.

N.O. Com.

N.C.

N.C.

N.O.

N.O. Com.

Com. N.C.

N.C.


Key Switch British standard size

KS-7510A

KS-860

KS-860S

Mortise mount Stainless steel faceplate Switch rating: 4A/125VAC

Mortise mount Stainless steel faceplate Suitable for Euro profile cylinder (not included) Switch rating: 4A/125VAC Momentary or Maintained SPDT

Surface mount Stainless steel faceplate Suitable for Euro profile cylinder(not included) Switch rating: 4A/125VAC Momentary or Maintained SPDT

SMB-86ALU-03 European standard size Anodized and Brushed

Application: The connection to fail-safe lock devices:

. Com. N.C

le ptib erru upply t n i Un wer S Po

ch swit Keytdoor) (ou

The connection to fail-secure lock devices:

tible rrup pply e t n Uni er Su Pow . Com. N.O

tput

u ay o . Com . N.C

Rel

vice k De Loc l-safe) k (fai to Loc er Pow

ch swit Keytdoor) (ou

tput you Rela om. C . N.O

vice k De Loc secure) ck (fail to unlo er Pow 3 6 9 #

3 6 9 #

2 5 8 0

2 5 8 0

1 4 7

*

1 4 7

*

der Rea oor) d (out

der Rea oor) d (out

73


Key Switch ANSI & Narrow Size

ANSI standard sized

KS-500

KS-700W

KS-750LD

Mortise mount Stainless steel faceplate Switch rating: 5A/125VAC Momentary SPDT switch (Cyclinder is not included)

Mortise mount Stainless steel faceplate Switch rating: 5A/125VAC (Cyclinder is not included)

Mortise mount Stainless steel faceplate Switch rating: 5A/125VAC (Cyclinder is not included)

Narrow Size

SMB-750 ANSI size Zinc anodized Surface mount

74

KS-900 KS-900LD Mortise mount Stainless steel faceplate Switch rating: 5A/125VAC Maintained DPDT (KS-900) Maintained SPDT (KS-900LD)

SMB-370ALU For KS-900 Chromium anodized Surface mount


Access Control Accessories The peripherals of electric locks are essential and can upgrade the performance of the access control system, e.g. door loop, surface mount housing, interlock module‌etc.

75


Access Control Accessories

Mortise Mount Door Loop

Surface Mount Door Loop

DL-200

DL-350 50 DL-350-SP (spring)

Length:40cm Triangle plastic sleeve

Length:40cm Square aluminum sleeve

Position Ball Series

PB-100

DL-400 Length:29cm

Mortise Mount Door Loop Application

Door Latch

SWH-10405

LS-1802GF

Bolt switch SPDT(COM,N/C,N/O) M18 X P1.0mm

Auxiliary latch

Bond Sensor Status LED Indicator

LS-2000

TLM-300S

TLM-400S

Auxiliary latch Compatible with GK series electric strikes Adjustable latch throw 10~19mm

Door Status Indicator Operating voltage: 12/24VDC Current draw : 40mA/12VDC 50mA/24VDC

Door Status Indicator Operating voltage: 12/24VDC Current draw : 40mA/12VDC 50mA/24VDC

76


Access Control Accessories

Bond Sensor Status LED Indicator

TLM-100MTS

TLM-200

Operating voltage: 12~24VDC With SMB-040 back box for surface mount

Operating voltage:12~24VDC With SMB-86ALU back box for surface mount

Switching Module:

SM1224-1A

PSM-S1A12V

SM1228

Mini Voltage Switching Module Power input :15~24VAC 16~28VDC Output : 300mA/12VDC

Waterproof Switching Module Power input: 12~28VAC 12~50VDC Output: 1A/12VDC

Power Transformer Module Power input: 13~28VDC Output:300mA/12VDC

DBR-200

GPD-3015-PLUS

FFP-1224

Power input: 8~30VAC 11~30VDC Relay module When power input then contacts will change over from N/C (Normally Close) to N/O (Normally Open)

Voltage Distribution Board DC voltage averagely distributed to five output contacts Each OUTPUT is protected by individual PPTC from over current Therefore each load of output may not exceed 1AMP

PSU Interface module for Fire alarm panel Power Input:12~24VDC Output:12~24VDC Relay rated: 6A/125VAC~12A/125VAC 12A/28VDC Dimensions: 47(L) x 59 (W) mm