PRO3200 Professional Modular Access Control Hardware

PRO3200 Access Control Hardware

PRO3200 Modules

As a part of the WIN-PAK software controlled hardware family the

The PRO3200 professional series family of access control modules

PRO3200 professional modular access control hardware is an

is connected to an interface with the main controller (PRO32IC)

advanced access control panel capable of providing solutions where

through a supervised RS485 bus. Hardware interface

installation space is at a premium. The design of the hardware is

configuration options are stored in the main controller and may be

modular and flexible and can be tailored to meet a wide range of

directly controlled via operator intervention, time schedules or

applications, while optimising cost and mounting space.

event-based procedures. The modules have been designed to

®

The PRO3200 system is connected to a host computer with WIN-

allow for a modular customisable solution.

PAK for system configuration, alarm monitoring and direct control.

PRO3200 Reader Modules

Using WIN-PAK SE 4.0 / PE 4.0 or higher, at least 255 PRO3200

The PRO32R2 supports two card access readers to control two

systems can be connected to create large access control solutions.

doors. In the event that communication to the intelligent control

Every PRO3200 consists of a main controller, one or more

module is lost, the card access readers can be individually

enclosures, power supplies and reader or I/O modules. A PRO3200

configured to allow entrance based on security needs.

system can be set up as an access control system with up to 32

This customisation allows for a door to be configured as locked,

doors, protected with one reader each door. If additional inputs and

unlocked or access only via a valid facility code.

outputs are needed for extra control within the PRO3200 system, the number of controllable doors will be limited to less than 32 doors. The access control limitations depend on the amount of extra controllable inputs and outputs needed within the modular configuration of up to 16 I/O or reader boards.

PRO3200 I/O Modules The PRO32OUT module provides 12 Form C, 12 VDC, 2A relay output controls when mounted in a high density rack mount enclosure (PRO22ENC1 and PRO22ENC2). If the board is tile mounted in a PRO22ENC3, four extra Form C, 12 VDC, 2A relay

Designed to fit into tight spaces, the PRO3200 with its rack-mount

output controls and power fail and panel tamper inputs are

design provides high-density installations for up to 16 doors per

provided. Relays may be used for lift control, status annunciation

cabinet in a small space. The design makes it ideal for applications

and for general facility control.

where eight or more doors are needed. Metal enclosures for up to two modules are available for remote located controllable doors, connected via a supervised RS485 bus.

The PRO32IN module provides 16 supervised alarm inputs and a dedicated power fail and panel tamper when tile mounted. The inputs can be supervised with end-of-line resistors or non-

PRO3200 Main Controller

supervised (digital). Inputs may be used for status and for general

The PRO3200 main controller board (PRO32IC) accommodates a

facility monitoring, such as door monitoring.

card database of 100,000 cards, a transaction buffer of 50,000 transactions and is designed to operate off-line, making access control decisions independently from a PC or other controlling devices.

Enclosures for PRO3200 devices The PRO3200 main controller and modules are designed to accommodate various mounting options. Units can be mounted in a

The PRO32IC supports any combination of up to 16 I/O or reader

high-density rack configuration (PRO22ENC1 and PRO22ENC2)

boards to monitor alarm input points, relay output points and access

when space is limited or in a tile-mount configuration (PRO22ENC3)

control reader interface points. Connectivity to the host computer with

for remotely located doors and I/O. A high-density enclosure can

WIN-PAK SE 4.0 / PE 4.0 or higher is accomplished via on board

facilitate a power supply, a main controller and up to eight modules.

Ethernet port, serial (RS232) communication or dial-up modem.

• PRO22ENC1 is a wall-mounted high-density enclosure • PRO22ENC2 is a 19" rack-mounted high-density enclosure • PRO22ENC3 is a wall-mounted remote enclosure for up to two modules or main controllers


PRO3200 Professional Modular Access Control Hardware

S Y S T E M F E AT U R E S • Configurable via WIN-PAK SE 4.0 / PE 4.0 or higher access control software • At least 225 PRO3200 systems

• Supervised communication and lithium battery backup ensures system reliability • Large, local controller database allows

• Any combination of 16 I/O or reader modules may be connected to the PRO32IC RS485 ports at 38,400 bps.

configurable in a WIN-PAK hosted system

access control decisions to be made by

1250m total bus length per port.

to meet the needs of large access control

controller in real time without the need to

• Accommodates a card database of

and security systems

communicate to the server

• Scalable architecture ensures optimal

• Seamless support for TCP/IP protocols to

performance with a seamless upgrade

allow intelligent controller(s) to tap into a

path to accommodate future growth

LAN or WAN

beyond its initial installation • Rack or tile mounting options available

• True 32-bit microprocessor provides fast transaction processing for the most demanding network applications

100,000 cards, and a transaction buffer of 50,000 transactions • Option to include or exclude fields during database configuration to maximise memory usage • Automatic calculation of leap-year and daylight savings

A C C E S S C O N T R O L F E AT U R E S • Supports a wide range of reader

• Configurable as fail-secure (energise

technologies including Wiegand, magnetic

to activate) or fail-safe (de-energise

stripe, proximity, smart card and keypad

to activate)

• Supports multiple reader and card formats for maximum flexibility and security options • System off-line modes customisable per reader include facility code access, locked (no access) and unlocked (full access) • Operating modes include locked, unlocked, facility code, card only, card and PIN, card or PIN and PIN only

• Activation and deactivation dates by card • Up to 12 intervals per time zone where each interval is a start time, stop time and

• Up to eight card formats per reader

day map. The day map indicates the day

• Anti-passback support

of the week or holiday

• Up to 32 access levels per card or individual time zones per readers • 10-digit (32-bit) user ID standard / 15-digit maximum

• 255 possible holidays are defined by a starting date and duration • Entire card bit-stream reported with invalid facility code or invalid card format

• Personal Identification Number (PIN) with up to eights digits

I N P U T / O U T P U T C O N T R O L F E AT U R E S • User programmable relay outputs allow for specific control needs • Pulse control: single pulse (up to 255 seconds) or repeating pulses (on/off in 1 second increments, up to 255 times)

• Configurable as standard, entry delay

• Alarm circuit type - normally open,

latching, entry delay non-latching and

normally closed, non-supervised,

exit delay

supervised (with correct EOL). Meets

• User programmable alarm inputs offer

requirements for UL294 and CUL

flexible system configuration and control

E N C L O S U R E F E AT U R E S • User programmable relay outputs allow for specific control needs • Pulse control: single pulse (up to 255 seconds) or repeating pulses (on/off in 1 second increments, up to 255 times)

• Configurable as standard, entry delay

• Alarm circuit type - normally open,

latching, entry delay non-latching and

normally closed, non-supervised,

exit delay

supervised (with correct EOL). Meets

• User programmable alarm inputs offer flexible system configuration and control

requirements for UL294 and CUL


S Y S T E M S P E C I F I C AT I O N S Database:

Access Modules:

Enclosures:

• Flash programming for firmware

• 16 total devices/modules available per

• PRO22ENC1 (Wall-mount)

revision updates • Memory for 100,000 cards

PRO32IC controller • PRO3200 modules available:

• Memory for 50,000 events

- Dual reader module (PRO32R2)

• Access codes: Unlimited

- 16 relay output module (PRO32OUT)

• Holidays: Unlimited

- 16 alarm input module (PRO32IN)

• Time codes: 255, 64 supported by WIN-PAK

• Backward compatible with PRO2200

Capacity: nine modules. Power supply and battery not included • PRO22ENC2 (19" Rack-mount) Capacity: nine modules. Power supply and battery not included • PRO22ENC3 (Tile-mount)

modules:

Capacity: Two modules. Battery included.

• Card reader formats: eight per reader

- Single reader module (PRO22R1)

Recommended Power Supply: PSX220

• Credential facility codes: eight

- Dual reader module (PRO22R2)

Transformer 240VAC / 16VAC

• Lift support: 240 floors (relays)

- 16 relay output module (PRO22OUT)

Dimensions:

• Dedicated tamper alarm

- 16 alarm input module (PRO22IN)

• PRO3200 Board: 22.86 cm H x 13.97 cm

• Dedicated power fail alarm • Real time clock: - Geographic time zone support

• Module connectivity via RS485 protocol (1250m)

- Daylight Saving Time

Access Control Operational Functionality:

- Leap year support

• Duress detection

- 4-bit parallel accurate to 50 ppm

• Operational modes:

• Precision access groups/levels

- Card only

• Multiple access groups/levels

- PIN only

Communication: • Primary communication support: - On board Ethernet (TCP/IP) - RS232 - Dial-up modem* • Communication speed: 38.4 Kbps • Automatic dial back: - Dial-back on alarm condition - Dial-back on transaction buffer capacity reached - Dial-back on primary power loss • Download functionality: - System functional during system download: Yes - System functional during credential download: Yes *Requires additional hardware

W x 2.54 cm D • PRO22ENC1: 35.3 cm H x 43.18 cm W x 22.86 cm D • PRO22ENC2: 35.3 cm H x 48 cm W x 22.86 cm D • PRO22ENC3: 35.56 cm H x 40.64 cm W x 10.2 cm D

- Card or PIN

Environment:

- Card and PIN

• Temperature: 0°C to 49°C operational;

- Facility code only • Maximum PIN size: 8 digits • Door object support • Two person access rule • Offline modes (selectable per reader): - Facility code access - Locked (no access) - Unlocked (free access) • Anti-Passback support via RS485 modules: - While preventing access (hard) - While allowing access (soft) • Transaction prioritisation: 99 levels

-55°C to 85°C storage • Humidity: 0 to 85% RHNC

Wiring Requirements: • Power - twisted pair, 18 AWG • RS485 - 24 AWG, 1,200m max, two twisted pairs with shield (120 W, 23 pF, Belden 9842 or equivalent) • RS232 - 24AWG, 7.6 m max • Alarm input - twisted pair, 30 ohms max


PRO3200 Professional Modular Access Control Hardware

M O D U L E S P E C I F I C AT I O N S Reader Modules PRO3200 Series Dual Reader Module (PRO32R2) Module Specifications Port

2 reader ports - 12 VDC at 50 mA, clock / data or data0 / data1

Keypad

Keypad multiplexed with card data

Wire Support

Two-wire or one-wire bi-colour LED support

Buzzer Support

Buzzer support only with one-wire LED control 4 supervised, door status and egress inputs and 2 general purpose alarm inputs with programmable circuit type (2 additional supervised inputs available when using PRO22ENC3 enclosure)

Door Alarm Inputs Alarm Inputs

2 dedicated alarm inputs for tamper detection and power loss

Door Control Relays Output Relays

2 general purpose output relays, form C, 5 A 28 VDC 2 general purpose output relays, form C, 2 A 28 VDC (2 additional output relays available when using PRO22ENC3 enclosure)

Alarm Input Properties Inputs

Inputs may be assigned to door related functions or general purpose I/O Circuit type - normally open, normally closed, non-supervised, supervised (with standard 1K or custom end-of-line resistance 200-10K)

Circuit Type Line Conditioning

Line conditioning - programmable sensitivity and hold time

Output Control Properties Outputs

Outputs may be assigned to door related functions or general purpose I/O

Relay Rating

The 5 A relay(s) are rated to handle the inductive loads of door locking devices

Configurable

Configurable as fail-secure (energise to activate) or fail-safe (de-energise to activate)

Pulse Time

1-32,400 seconds, 1-255 for door relays

RS485 Port

RS485 port, 1,250m total bus length

Default Speed

38.4 Kbps

I/O Modules PRO3200 Series 16 Relay Output Module (PRO32OUT) Module Specifications Alarm Inputs

2 dedicated alarm inputs for tamper detection and power loss (tile-mounted only)

Alarm Inputs Output Relays

PRO3200 Series 16 Alarm Input Module (PRO32IN)

N/A

16 general purpose inputs with programmable circuit type

12 general purpose output relays, form C, 2 A 30 VDC (four additional are available when using PRO22ENC3 enclosure)

1 general purpose, form C, 2 A 30 VDC relay (one additional is available when using PRO22ENC3 enclosure)

Output Control Properties Outputs

All 16 relay outputs (mounted in PRO22ENC3) or 12 relay outputs (in PRO22ENC1 and PRO22ENC2) are available for general purpose I/O

Both relay outputs are available for general purpose I/O

The 2 A relays are rated to handle dry circuit logic

Both relay outputs are rated to handle dry circuit logic

Dry Circuit Logic Pulse Time Configurable

1-32,400 seconds Configurable as fail-secure (energise to activate) or fail-safe (de-energise to activate)

N/A

Alarm Input Properties Inputs

N/A

All 16 inputs may be assigned to door related functions or general purpose I/O

Circuit Type

N/A

Circuit type - normally open, normally closed, non-supervised, supervised (with correct EOL)

Line Conditioning

N/A

Line conditioning - programmable sensitivity and hold time

Communication Features Measurements Default Speed

RS485 port, 1250m total bus length per port 38.4 Kbps


T Y P I C A L S Y S T E M C O N F I G U R AT I O N

PRO22ENC1 and PRO22ENC2 Module

PRO22ENC3

Reader

Inputs

Outputs

Inputs

PRO32R2

2

6

4

10**

6

PRO32OUT

0

0

12

2**

16

PRO32IN

0

16

1

18**

2

**Two are used to monitor Power and Tamper PRO22ENC1 and PRO22ENC2=9 Board Capacity / PRO22ENC3=2 Board Capacity

Outputs


PRO3200 Professional Modular Access Control Hardware

ORDERING PRO3200 Controllers and Modules

PRO3200 High Density Enclosures and Accessories

PRO32IC

PRO3200 Intelligent Controller

PRO22ENC1

PRO32R2

PRO3200 Dual Reader Module

power supply, main controller and up to

PRO32OUT

PRO3200 16* Relay Output Module

eight modules. Power supply and battery

PRO32IN

PRO3200 16 Alarm Input Module

not included PRO22ENC2

modules. Power supply and battery not

(add PRO3200 Modules to complete configuration)

included

PRO3200 Kit , including PRO32IC, PRO22ENC1, PRO32E1PS, PRO22BAT1,

PRO32E1PS

PRO22DCC

PRO3200 Kit , including PRO32IC,

PRO3200 power/communication daisy chain harness

PRO22ENC2, PRO32E1PS, PRO22BAT1, PRO22DCC

110V/240VAC - 12VDC /4 A rack-mounted power supply with battery backup

PRO22DCC PRO32E2EN

19" Rack-mount, high-density enclosure for power supply, main controller and up to eight

PRO3200 High Density Enclosure kit

PRO32E1EN

Wall-mount, high-density enclosure for

PRO3200 Remote Enclosure and Accessories PRO22ENC3

Wall-mount enclosure with battery for two modules. Power supply not included

PSX220 * Only 12 relay outputs are available when using the PRO22ENC1 and PRO22ENC2 enclosures

For additional information, please visit www.honeywell.com/security/uk Honeywell Security Group Aston Fields Road Whitehouse Industrial Estate Runcorn Cheshire WA7 3DL Tel: 08448 000 235 www.honeywell.com