TERMI NALKUALA LUMPUR SENTRAL
PRODUCED BY AN AUTODESK STUDENT VERSION
List of Drawings No.
Drawing Title
1
Master Plan
2
Platform
1 : 250
AAD 3231 D01
29
3
Level 1
1 : 250
AAD 3231 D02
4
Level 2
1 : 250
5
Level 3
1 : 250
Drawing No.
Scale
Drawing No.
Platform
1 : 250
AAD 3231 D21
30
Level 2
1 : 250
AAD 3231 D22
AAD 3231 D03
31
Level 3
1 : 250
AAD 3231 D23
AAD 3231 D04
32
Section A - A
1 : 250
AAD 3231 D24
33
Section B - B
1 : 250
AAD 3231 D25
Floor Plan
No.
Drawing Title
28
Electrical Layout
7
Platform
1 : 250
AAD 3231 D05
34
Section C - C
1 : 250
AAD 3231 D26
8
Level 1
1 : 250
AAD 3231 D06
35
Elevation Lobby Hallway
1 : 250
AAD 3231 D27
9
Level 2
1 : 250
AAD 3231 D07
36
Selected Area 1
1 : 50
AAD 3231 D28
10
Level 3
1 : 250
AAD 3231 D08
37
Detail Drawing A & B
1 : 25
AAD 3231 D29
38
Detail Drawing C & D
1 : 25
AAD 3231 D30
11
Furniture Layout
12
Platform
1 : 250
AAD 3231 D09
39
Detail Drawing E, F & G
1 : 10
AAD 3231 D31
13
Level 2
1 : 250
AAD 3231 D10
40
Detail Drawing H
1 : 10
AAD 3231 D32
14
Level 3
1 : 250
AAD 3231 D11
41
Selected Area 2
1 : 25
AAD 3231 D33
40
Detail Drawing I & J
1 : 10
AAD 3231 D34
41
Detail Drawing K
1 : 25
AAD 3231 D35
16
Floor Finishes Layout
17
Platform
1 : 250
AAD 3231 D12
18
Level 2
1 : 250
AAD 3231 D13
19
Level 3
1 : 250
AAD 3231 D14
20
Reflected Ceiling Plan
21
Platform
1 : 250
AAD 3231 D15
22
Level 2
1 : 250
AAD 3231 D16
23
Level 3
1 : 250
AAD 3231 D17
24
Lighting Layout Plan
25
Platform
1 : 250
AAD 3231 D18
26
Level 2
1 : 250
AAD 3231 D19
27
Level 3
1 : 250
AAD 3231 D20 Copyright 2019 RVICHIII studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHIII studio.
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
6
Scale
PRODUCED BY AN AUTODESK STUDENT VERSION
7
6
8
9
10
11
12
13
14
15
95221 10049
9985
10016
15153
10008
9967
10027
10010
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
10010
10361
B
PLATFORM 1 AND 2
PLATFORM 1 AND 2
C
MP
Master Plan \ platform Scale 1 : 2 5 0
Copyright 2020 RVICHIII studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Master Plan \ platform
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 0 1
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
5
7
6
10000
8
9
10000
10000
10000
10
13
12
11
20000
10000
10000
14
10000
15
16
10000
5325
A
B 9629
C
D
RAPID KL
E
9336
E1
KTM TICKETING COUNTER
F G TO PLATFORM 5 AND 6
TO PLATFORM 5 AND 6
KTM
17653
KTM
KTM TICKETING COUNTER
TO PLATFORM 3 AND 4
G1
TO PLATFORM 3 AND 4
6600
INFORMATION COUNTER
MCDONALD
MAJOR EXCLUSIVE CURRENCY EXCHANGE
ATM MACHINE
MYNEWS.COM SHOP LOT
SAMSUNG 6933
H TOURIST INFORMATION CENTER
AHU ROOM
TUNETALK
AHU ROOM
PANETTONE
MEAL STATION
MP
Master Plan \ level 1 Scale 1 : 2 5 0
Copyright 2020 RVICHIII studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Project:
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Master Plan \ level 1
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 0 2
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
6635
RAPID KL
PRODUCED BY AN AUTODESK STUDENT VERSION 5
7
6
9987
10
9
10065
19951
13
12
11
A
9969
8
20036
SECTION
4
9961
14
10000
10000
15
10000
16
10000
SITE BOUNDRIES
A SKYPARK LINK WAITING AREA
KTM ETS WAITING AREA
GLASS WALL NILE MONEY CHANGER
15256
GLASS WALL
GLASS WALL
PRODUCED BY AN AUTODESK STUDENT VERSION
10344
KFC ESCALATOR TO PLATFORM A (1 AND 2)
ESCALATOR TO PLATFORM B (1 AND 2)
C 5331
POLICE STATION RWP'S MER1 RWDP CHWP FIRE PIPE
D
ACMV
INFORMATION COUNTER
FT
KTM OFFICE
ACMV
TOILET EXHAUST SMOKE SPILL FA
ESCALATOR AND STAIRS TO GROUND FLOOR
H.R FT
ELEC
11000
FE
H
TOILET KTM OFFICE KOMUTER LINK COUNTER
KOMUTER LINK COUNTER
KOMUTER LINK COUNTER
TOILET
FT
COM
K
E
8800
K
WAITING AREA
WAITING AREA
WAITING AREA
F
KTM ETS TICKET COUNTER
I-CARD STUDENT COUNTER
BUDGET TAXI TICKET COUNTER K
KTM ETS TICKET COUNTER
RWO
RWO
RWO
RWO
RWO
RWO
RWO
K
KTM ETS TICKET COUNTER
RWO
RWO
K
11000
MAIN ENTRANCE (HILTON, LE MERIDIAN HOTEL)
RWO
RWO
ACMV2
K
RWO
A
SECTION
G SITE BOUNDRIES
MP
Master Plan \ level 2 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Project:
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Master Plan \ LEVEL 2
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 0 3
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
B
PRODUCED BY AN AUTODESK STUDENT VERSION
4
5
7
6
9969
9987
8
10
9
10065
19951
A
15256
SKYPARK LINK WAITING AREA
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
GLASS WALL
B
10344
KFC
VIP LOUNGE
GALLERY
5331
C
D INFORMATION COUNTER
11000
FT
ESCALATOR AND STAIRS TO GROUND FLOOR TOILET
E BRIDGING
8800
FOUND 8 (CO-WORKER SPACE)
F
11000
MAIN ENTRANCE (HILTON, LE MERIDIAN HOTEL)
RWO
RWO
RWO
RWO
RWO
RWO
MP
G
Master Plan \ level 3 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Master Plan \ LEVEL 3
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 0 4
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
7
6
8
9
10
11
12
13
14
15
95221
PRODUCED BY AN AUTODESK STUDENT VERSION
10049
9985
10016
15153
10008
9967
10027
10010
10361
B
PLATFORM 1 AND 2
PLATFORM 1 AND 2
C
FP
Floor Plan \ platform Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Floor Plan \ platform
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 0 5
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
10010
PRODUCED BY AN AUTODESK STUDENT VERSION
6
7
8
9
10
11
12
13
14
15
95221 10010
10049
9985
10016
15153
10008
9967
10027
10010
10361
PLATFORM 1 AND 2
PLATFORM 1 AND 2
C
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
B
PRODUCED BY AN AUTODESK STUDENT VERSION
4
5
7
6
8
10
9
59971 10000
9969
9987
10065
9944
B
SECTION
A
10006
A
A
SECTION
SECTION
WAITING AREA
STARBUCKS
15256
SUBWAY CAFE
DEPARTURE GATE SEATING 1
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
B
TICKET VENDING BOOTH
10344
SEATING AREA 3
ARRIVAL GATE
C
SEATING 2
D
61731
5331
VENDOR 1
VENDOR 3
11000
VENDOR 2
SEATING AREA 5 TOILET
TICKET VENDING BOOTH
E SEATING AREA 4
8800
INFORMATION COUNTER
LOBBY HALLWAY
WORK STATION
F D19
TICKET COUNTER
11000
CHARGING AREA
RWO
RWO
RWO
RWO
RWO
RWO
GRABCAR WAITING AREA
G
B
SECTION
FP
Floor Plan \ level 2 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Floor Plan \ level 2
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 0 7
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
7
8
10
9 30016
10065
9944
C
C
SECTION
SECTION
PRODUCED BY AN AUTODESK STUDENT VERSION
SLEEPING CAPSULE
10344
PRODUCED BY AN AUTODESK STUDENT VERSION
B
10006
MALE MUSOLLA
C 5331
26676
ABULATION AREA
D
11000
FT
TOILET
E BRIDGING
FP
Floor Plan \ level 3 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Floor Plan \ level 3
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 0 8
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
6
7
8
9
10
11
12
13
14
15
95221 10049
9985
10016
15153
10008
9967
10027
10010
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
10010
B
10361
Y203
Y203
PLATFORM 1 AND 2
PLATFORM 1 AND 2
C
Eletrical Legend Code Description
Quantity
Y203
2
Wood Parametric Design Bench 6.5m
FL
Furniture Layout \ platform Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Furniture Layout\ platform
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 0 9
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
4
5
7
6
8
10
9
59971 10000
9969
9987
10065
10006
9944
Furniture Legend Loose Furniture
B
SECTION
A
C201
A
C202
T201 K202 C201
SECTION
Y202
C202
A
K202
T202
SECTION
C201
Y210 C201
Y201 K203
C201
C201
C202
Y201
K203
WAITING AREA
T201
STARBUCKS
C201
C201
C202
K201
SUBWAY CAFE
Y209
15256
Y201
Code Description
Quantity
C201
Vintage Dining Chair
12
C202
Coat Leather ArmChair
4
C203
Executive Office Chair
6
C204
Gaming Office Chair
6
C205
Round Designer Chair
6
B201
Steel Bench 1.5m
15
T201
Glass Top Dining Table
3
T202
Marble Square Top Table
1
T203
Wood Top Dining Table
2
T204
Round Wood High Table
3
T205
Square Wood High Table
3
K201
Wood Cabinet 118x110cm
2
K202
Lower Cabinet 6 Doors
2
K203
Lower Cabinet 4 Doors
2
S201
Wood Round Stool
24
K201 Y202
C201
C201 C201 T201
DEPARTURE GATE
C201
SEATING 1
PRODUCED BY AN AUTODESK STUDENT VERSION
B201
B201
B201
B201
B201
Y203
TICKET VENDING BOOTH
10344
SEATING AREA 3
Furniture Legend ARRIVAL GATE
Custom Furniture B201
C
B201
B201
B201
Code Description
SEATING 2 VENDOR 1
5331 61731
D
B201
C205 C205
Y201
Custom Coated Fabric Round Banquet
3
Y202
Custom Coated Fabric Banquet
2
Y203
Wood Parametric Design Bench 6.5m
1
Y204
Custom Long Executive Counter Desk
2
Y205
Steel Parametric Bench 6.3m
1
Y206
Custom Side Sofa With Desk
2
Y207
Custom Aisle 4 Sided Sofa
6
Y208
Working Desk
3
Y209
Custom 10 Doors Low Cabinet with Sink
1
Y210
Custom 10 Doors Low 1 Cabinet with Food Display
Y211
3 Sides Custom Office Desk
T203 C205
VENDOR 3 T203
C205
VENDOR 2
11000
C205 C205
SEATING AREA 5 TOILET
Y204
TICKET VENDING BOOTH
E
C203
C203
Y204 Y205
SEATING AREA 4
8800
INFORMATION COUNTER
LOBBY HALLWAY
WORK STATION
F
C204
S201 S201
11000
S201
Y207
Y207
S201
Y208
S201 T204
Y206
Y207
S201 Y207
D19
TICKET COUNTER
Y208
C204
S201 S201
S201 Y208
C204
S201
T204
Y207 Y207
Y211
T204
CHARGING AREA Y206
C204 Y211
Y211
Y211
Y211
C204
C204 S201
S201
S201
S201 T205
T205
T205
S201 S201
S201
Quantity
S201
RWO B201
B201
B201
B201
RWO
RWO
RWO
RWO
6
RWO
B201
GRABCAR WAITING AREA
G
B
SECTION
FL
Furniture Layout \ level 2 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Furniture Layout\ level 2
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 1 0
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
B
PRODUCED BY AN AUTODESK STUDENT VERSION
7
8
10
9 30016
10065
B
10006
9944
C
C
SECTION
SECTION
B201
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
10344
SLEEPING CAPSULE
MALE MUSOLLA
K201
C 5331
26676
ABULATION AREA
D
11000
FT
TOILET
E BRIDGING
Furniture Legend Loose Furniture Code Description B201 K201
Single Soundproof Capsule Bed 2.4m x 1.2m Wood Cabinet 118x110cm
Quantity 7 1
FL
Furniture Layout \ level 3 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Furniture Layout\ level 3
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 1 1
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
6
7
8
9
10
11
12
13
14
15
95221 10049
9985
10016
15153
10008
9967
10027
10010
10361
B
PLATFORM 1 AND 2
PLATFORM 1 AND 2
C
Floor Finishes Legend Symbol Description 12" x 12" Ceramic Tiles
Note -
All m&e to be forwarded to m&e consultant. These drawings are to used for information only. Prior to installation all set outs are to be confirmed and approved by designer. All discrepancies between drawings and site conditions to be brought to the immediate attention of the designer. All fittings and specifications are to be respected unless an alternative is source approved by the designer.
FFL
Floor Finishes Layout \ platform Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Floor Finishes Layout\platform
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 1 2
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
10010
PRODUCED BY AN AUTODESK STUDENT VERSION
4
5
7
6
8
10
9
59971 10000
9969
9987
10065
9944
B
SECTION
A
10006
A
A
SECTION
SECTION
Floor Finishes Legend Symbol
WAITING AREA
STARBUCKS
Description Selected Epoxy Coating
SUBWAY CAFE
15256
Selected Wood Laminate 8" x 8" Sandblast Granite Tile Selected Wood Parquet 8" x 8" Terrazo Tiles 12" x 12" Ceramic Tiles
DEPARTURE GATE
8" x 8" Non Slippery Tiles
SEATING 1
B
PRODUCED BY AN AUTODESK STUDENT VERSION
Selected Wood Parquet
SEATING AREA 3
10344
Selected Carpet Tiles Selected Wood Veneer Selected Wood Parquet
ARRIVAL GATE
C
SEATING 2
D
61731
5331
VENDOR 1
Note VENDOR 3
11000
VENDOR 2
-
All m&e to be forwarded to m&e consultant. These drawings are to used for information only.
-
Prior to installation all set outs are to be confirmed and approved by designer.
-
All discrepancies between drawings and site conditions to be brought to the immediate attention of the designer.
-
All fittings and specifications are to be respected unless an alternative is source approved by the designer.
SEATING AREA 5 TOILET
TICKET VENDING BOOTH
E SEATING AREA 4
8800
INFORMATION COUNTER
LOBBY HALLWAY
WORK STATION
F D19
TICKET COUNTER
11000
CHARGING AREA
RWO
RWO
RWO
RWO
RWO
RWO
GRABCAR WAITING AREA
G
B
SECTION
FFL
Floor Finishes Layout \ level 2 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Floor Finishes Layout\level 2
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 1 3
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
Selected Embossed Tiles TICKET VENDING BOOTH
PRODUCED BY AN AUTODESK STUDENT VERSION
7
8
10
9 30016
10065
10006
9944
Floor Finishes Legend
PRODUCED BY AN AUTODESK STUDENT VERSION
C
C
SECTION
SECTION
Symbol
Description 12"x12" Ceramic Tiles 4"x4" Non Slippery Tiles
10344
SLEEPING CAPSULE
Selected Carpet Tiles Selected Carpet Tiles 8"x8" Non Slippery Tiles
MALE MUSOLLA
8"x8" Sandblast Granite
C 5331
26676
ABULATION AREA
Note
D
All m&e to be forwarded to m&e consultant. These drawings are to used for information only.
-
Prior to installation all set outs are to be confirmed and approved by designer.
-
All discrepancies between drawings and site conditions to be brought to the immediate attention of the designer.
-
All fittings and specifications are to be respected unless an alternative is source approved by the designer.
FT
11000
-
TOILET
E BRIDGING
FFL
Floor Finishes Layout \ level 3 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Floor Finishes Layout\level 3
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 1 4
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
B
PRODUCED BY AN AUTODESK STUDENT VERSION
6
7
8
9
10
11
12
13
14
15
95221 10010
10049
9985
10016
15153
10008
9967
10027
10010
Ceiling Legend Symbol
10361
B -
c02 -2800
PLATFORM 1 AND 2
PLATFORM 1 AND 2
c06 -2500
C
c02 -2800
c06 -2500
Description Ceiling Type Height from +0.00 Floor Level
c02 -2800
Flush 12mm Fibrous Plasterboard Suspended Finish with Brown Paint Generally unless Noted
c06 -2500
Custom Design Wavy Strip Suspended 50mm Thick Vibration Absorbing Steel
Note -
All m&e to be forwarded to m&e consultant. These drawings are to used for information only.
-
Prior to installation all set outs are to be confirmed and approved by designer.
-
All discrepancies between drawings and site conditions to be brought to the immediate attention of the designer.
-
All fittings and specifications are to be respected unless an alternative is source approved by the designer.
RCP
Reflected Ceiling Plan \ platform Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title Reflected Ceiling Plan \ platform
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 1 5
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
Ceiling Type
PRODUCED BY AN AUTODESK STUDENT VERSION
4
5
7
6
8
10
9
Ceiling Legend
59971 10000
9969
9987
10065
10006
9944
Ceiling Type Code
B
SECTION
-
c03
Description Ceiling Type Height from +0.00 Floor Level
+- 5000
A
A
A
SECTION
SECTION
WAITING AREA
c02 -2500
Flush 12mm Fibrous Plasterboard Suspended Finish with Brown Paint Generally unless Noted
Co2
3.8" pvc Suspended Ceiling Water and Corrosion Proof
Co3
30mm Glass Shade with 50% Sun Filter
Co4
Flush 12mm Gypsum Moisture Resistance Plasterboard
Co5
Custom Design Wavy Strip Suspended 50mmVibbration Absorbing Steel
Co6
50mm Roof Glazing
STARBUCKS
c02 -2500
15256
SUBWAY CAFE
DEPARTURE GATE SEATING 1
PRODUCED BY AN AUTODESK STUDENT VERSION
B
TICKET VENDING BOOTH SEATING AREA 3
10344
c04 -2800
ARRIVAL GATE
C
SEATING 2
5331 61731
D
c04 -2800
VENDOR 1
Note VENDOR 3
11000
VENDOR 2
c01 -3000
SEATING AREA 5
c01 -3000
-
All m&e to be forwarded to m&e consultant. These drawings are to used for information only.
-
Prior to installation all set outs are to be confirmed and approved by designer.
-
All discrepancies between drawings and site conditions to be brought to the immediate attention of the designer.
-
All fittings and specifications are to be respected unless an alternative is source approved by the designer.
TOILET
TICKET VENDING BOOTH
E
c04 -2800
SEATING AREA 4
8800
c01 -3000
c01 -3000
c01 -3000
INFORMATION COUNTER
c01 -3000 LOBBY HALLWAY
WORK STATION
F D19
TICKET COUNTER
11000
CHARGING AREA
c05 -2800
c01 -3000
c01 -3000
c01 -3000
G
B
SECTION
RCP
c06 -4000
Reflected Ceiling Plan \ level 2 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Reflected Ceiling Plan \ level 2
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 1 6
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
Co1
PRODUCED BY AN AUTODESK STUDENT VERSION
7
8
10
9
Ceiling Legend
30016 10065
10006
9944
Ceiling Type Code -
C
SECTION
SECTION
10344
PRODUCED BY AN AUTODESK STUDENT VERSION
C
SLEEPING CAPSULE
c01 -3000 MALE MUSOLLA
c01 -3000
C
Ceiling Type Height from +0.00 Floor Level
Co1
Flush 12mm Fibrous Plasterboard Suspended Finish with Brown Paint Generally unless Noted
Co2
3.8" pvc Suspended Ceiling Water and Corrosion Proof
Co7
Treated Strip Wood Panel
5331
26676
ABULATION AREA
D
Note 11000
FT
c02 -3000 TOILET
c01 -3000
c07 -2800
-
All m&e to be forwarded to m&e consultant. These drawings are to used for information only.
-
Prior to installation all set outs are to be confirmed and approved by designer.
-
All discrepancies between drawings and site conditions to be brought to the immediate attention of the designer.
-
All fittings and specifications are to be respected unless an alternative is source approved by the designer.
E BRIDGING
RCP
Reflected Ceiling Plan \ level 3 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Reflected Ceiling Plan \ level 3
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 1 7
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
B
Description
PRODUCED BY AN AUTODESK STUDENT VERSION
6
7
8
9
10
11
12
13
14
15
95221 10010
10049
9985
10016
15153
10008
9967
10027
10010
PRODUCED BY AN AUTODESK STUDENT VERSION
PLATFORM 1 AND 2
PLATFORM 1 AND 2
C
Note Lighting Legend
-
All m&e to be forwarded to m&e consultant. These drawings are to used for information only.
-
Prior to installation all set outs are to be confirmed and approved by designer.
-
All discrepancies between drawings and site conditions to be brought to the immediate attention of the designer.
-
All LED light strips are to be overlapped to provide a continuous even spread of diffused light.
-
Custom LED frame strip light need to refer with the designer
Lighting Type Code Description Custom Frame with LED Yellow Strip Light Recessed Down Light Warm White
LLP
Lighting Layout Plan \ platform Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title Lighting Layout Plan\platform
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 1 8
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
10361
B
PRODUCED BY AN AUTODESK STUDENT VERSION
4
5
7
6
8
10
9
59971 10000
9969
9987
10065
10006
Lighting Legend
9944
Lighting Type Code Description
A
B
SECTION
Custom Frame with LED Yellow Strip Light with Motion Sensor el Emergency Light
A
A
SECTION
SECTION
WAITING AREA
ac
Wall Mounted Split Unit Conditioner
STARBUCKS
SUBWAY CAFE
15256
Recessed Down Light Warm White Pendant LED Light Warm White LED Outdoor Light
DEPARTURE GATE M M
SEATING 1
B
M M
Wall Washer LED Light
TICKET VENDING BOOTH
10344
SEATING AREA 3
Wall mounted Fan LED Pendaflour Light
ARRIVAL GATE M
C
M
SEATING 2
M
M
5331
VENDOR 1
M
61731
M
D
Motion Sensor lighting switch
M M
ac
ac M M
M
Note
VENDOR 3
11000
VENDOR 2
SEATING AREA 5
-
All m&e to be forwarded to m&e consultant. These drawings are to used for information only.
-
Prior to installation all set outs are to be confirmed and approved by designer.
-
All discrepancies between drawings and site conditions to be brought to the immediate attention of the designer.
-
All LED light strips are to be overlapped to provide a continuous even spread of diffused light.
-
Custom LED frame strip light need to refer with the designer
TOILET
M
M
M
M
E
M
M
M
M
M
M
M
M
TICKET VENDING BOOTH
M
M
el
M
M
M
M
M
M
M
M
M
M
M
M
M
M
el
SEATING AREA 4
8800
INFORMATION COUNTER
M
M
M
M
F
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
LOBBY HALLWAY
WORK STATION
M
M
M
M
M
M
M
M
M
D19
ac
TICKET COUNTER
11000
CHARGING AREA
ac
ac
G
B
SECTION
LLP
Lighting Layout Plan \ level 2 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title Lighting Layout Plan\level 2
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 1 9
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
M
PRODUCED BY AN AUTODESK STUDENT VERSION
Lighting Legend 7
8
10
9
Lighting Type
30016 10065
10006
Code Description
9944
Custom Frame with LED Yellow Strip Light Recessed Down Light Warm White PRODUCED BY AN AUTODESK STUDENT VERSION
C
C
SECTION
SECTION
SLEEPING CAPSULE
10344
B
MALE MUSOLLA
C
Note
5331
26676
ABULATION AREA
-
All m&e to be forwarded to m&e consultant. These drawings are to used for information only.
-
Prior to installation all set outs are to be confirmed and approved by designer.
-
All discrepancies between drawings and site conditions to be brought to the immediate attention of the designer.
-
All LED light strips are to be overlapped to provide a continuous even spread of diffused light.
-
Custom LED frame strip light need to refer with the designer
D
11000
FT
TOILET
E BRIDGING
LLP
Lighting Layout Plan \ level 3 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Lighting Layout Plan\level 3
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 2 0
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
Hidden LED Strip Light
PRODUCED BY AN AUTODESK STUDENT VERSION
6
7
8
9
10
11
12
13
14
15
95221 10010
10049
9985
10016
15153
10008
9967
10027
10010
10361
PRODUCED BY AN AUTODESK STUDENT VERSION
PLATFORM 1 AND 2
PLATFORM 1 AND 2
C
Note -
Refer to mep drawings for extent of all exact electrical points and specifications.
-
These drawings are to be used for information only.
-
All switches to be in existing location unless noted otherwise.
-
Power provision for ptd should come from existing floor box unless otherwise instructed.
-
Outlet mounted at +300 a.f.l unless stated otherwise.
Eletrical Legend Code Description
Quantity 4
Single Power Outlet
EL
Electrical Layout\platform Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Electrical Layout\platform
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 2 1
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
B
PRODUCED BY AN AUTODESK STUDENT VERSION
4
5
7
6
8
10
9
59971 10000
9969
9987
10065
10006
9944
Eletrical Legend Code Description
72
Floor Mounted Single Power Outlet
5
Duplex Power Outlet
2
3 Phase Power Outlet
9
Above 1200mm Single Power Outlet
2
Above 1200mm 3 Phase Power Outlet
2
ac
Split Unit Air Conditioner
3
el
Emergency Light
2
Charging Port
3
LCD Monitor Screen
4
Telephone / WiFi
2
B
SECTION
Single Power Outlet f
A
3p
A SECTION
3p
3p
3p
3p
3p
3p
A SECTION
3p
3p
3p
WAITING AREA
STARBUCKS
15256
SUBWAY CAFE
3p
DEPARTURE GATE SEATING 1
TICKET VENDING BOOTH
f
SEATING AREA 3
10344
f
ARRIVAL GATE
C
SEATING 2
D
Note
61731
5331
VENDOR 1
-
Refer to mep drawings for extent of all exact electrical points and specifications. These drawings are to be used for information only.
-
All switches to be in existing location unless noted otherwise.
-
Power provision for ptd should come from existing floor box unless otherwise instructed.
-
Outlet mounted at +300 a.f.l unless stated otherwise.
VENDOR 3
11000
VENDOR 2
SEATING AREA 5 TOILET 3p
3p
TICKET VENDING BOOTH
E f
el
el
f
SEATING AREA 4
8800
INFORMATION COUNTER
LOBBY HALLWAY
WORK STATION
F ac
D19
TICKET COUNTER CHARGING AREA f
11000
f
ac
ac
f
RWO
RWO
RWO
RWO
RWO
RWO
GRABCAR WAITING AREA
G
B
SECTION
EL
Electrical Layout\ level 2 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Electrical Layout\level 2
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 2 2
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
B
PRODUCED BY AN AUTODESK STUDENT VERSION
Quantity
PRODUCED BY AN AUTODESK STUDENT VERSION
7
8
10
9 30016
10065
9944
C
C
SECTION
SECTION
10344
SLEEPING CAPSULE
MALE MUSOLLA
C 5331
26676
ABULATION AREA
Note
D
Refer to mep drawings for extent of all exact electrical points and specifications. These drawings are to be used for information only.
-
All switches to be in existing location unless noted otherwise.
-
Power provision for ptd should come from existing floor box unless otherwise instructed.
-
Outlet mounted at +300 a.f.l unless stated otherwise.
FT
11000
-
TOILET
E BRIDGING
Eletrical Legend Code Description
Quantity
Single Power Outlet
10
EL
Electrical Layout\ level 3 Scale 1 : 2 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Electrical Layout\level 3
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 2 3
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
B
10006
PRODUCED BY AN AUTODESK STUDENT VERSION
7
6
8
10
9
40002 10065
10006
9944
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
9987
L2
L1
GF
SC
Section A - A' Scale 1 : 1 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Section A - A'
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 2 4
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
A
B
C
E
D
F
G
61731 15256
10344
5331
11000
8800
11000
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
SC
Section B - B' Scale 1 : 2 0 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Section B - B'
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 2 5
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
7
8
9
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
SC
Section C - C' Scale 1 : 4 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Section C - C'
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 2 6
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
E1
Elevation Hallway Lobby Scale 1 : 4 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Elevation Hallway Lobby
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 2 7
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
Ceiling Design
D
Refer Drawing No. AAD 3231 D29 for detail and installation drawing.
SECTION
Built in Furniture 1
Refer Drawing No. AAD 3231 D32 for detail and installation drawing.
Detail Drawing 2 & 3 Refer Drawing No. AAD 3231 D31 for detail and installation drawing.
Loose Furniture 1 PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
Refer Drawing No. AAD 3231 D29 for detail and installation drawing.
Refer Drawing No. AAD 3231 D30 for detail and installation drawing.
Detail Drawing 1
D
Refer Drawing No. AAD 3231 D30 for detail and installation drawing.
SECTION
Floor Finishes 1
SA1
4100
Floor Finishes 2
Refer Drawing No. AAD 3231 D31 for detail and installation drawing.
Selected Area plan
SA1
Scale 1 : 5 0
Section D-D' Scale 1 : 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Selected Area 1\seating area
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 2 8
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
19
PVC base
Coated Polymer Fabric
- 19mm PVC coated with spray paint
Custom Coated Fabric Round Banquet - Selected polymer fabric
High Density Seat foam
120 60
- 5mm screw with wall plug
Vegetation Vase - Soil vase
Not to scale
35
PRODUCED BY AN AUTODESK STUDENT VERSION
FP1
Plan Seating 1
FS1
Scale 1 : 2 0
Treated Wood with Varnish
PRODUCED BY AN AUTODESK STUDENT VERSION
50
DA
Detail A
Section Seating 1 Scale 1 : 2 0
Stainless Steel
Detail B
DB
FP2
112
60
8mm Screw
Not to scale
Plan Furniture 1
FV1
Scale 1 : 1 0
Front View Scale 1 : 1 0
FV2
Side View Scale 1 : 1 0
FV3
Back View Scale 1 : 1 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Detail Drawing A & B
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 2 9
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
Selected Wood Parquet Interlocking Wood Parquet tile Adhesive
Cement Mortar & Sand
FF1
Floor Finishing 1
DC
Scale 1 : 1 0
Detail C Not to scale
Wood laminate with adhesive Selected Wood Laminate Treated wood decking based
Fixed Pedestal Support
Cement Mortar & Sand
Concrete Blinding
FF2
Floor Finishing 2
DD
Scale 1 : 1 0
Detail D Not to scale
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Detail Drawing C & D
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 3 0
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
Concrete Blinding
PRODUCED BY AN AUTODESK STUDENT VERSION
1 1/2" x 1 1/2" x 3/16" Diagonal 1/2" Joist
Sc1
Section Construction 1
DF
Scale 1 : 1 0
Detail F Not to scale
Treat wood plank
Handle with rubber grip 12" Bolt sunk to concrete
5'' bolt
DG
Detail E SC2
Not to scale
Section Construction 2 Scale 1 : 3 0
DG
Detail G Not to scale
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Detail Drawing E, F & G
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 3 1
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
Stainless steel frame
BC
Blow Up Ceiling
DH
Scale 1 : 1 0
CC
Detail H Not to scale
Ceiling Construction Details Scale 1 : 3 0 Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Detail Drawing H
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 3 2
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
SECTION
E
PRODUCED BY AN AUTODESK STUDENT VERSION
Refer Drawing No. AAD 3231 D34 for detail and installation drawing.
Built in Furniture 2 Refer Drawing No. AAD 3231 D34 for detail and installation drawing.
Wall Design
SECTION
E
Refer Drawing No. AAD 3231 D 35 for detail and installation drawing.
SA2
Selected Area Plan
SA2
Scale 1 : 5 0
Section E - E' Scale 1 : 5 0
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Project:
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title Selected Area 2\charging area
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 3 3
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
Loose furniture 2
PRODUCED BY AN AUTODESK STUDENT VERSION
Vinyl
50
Finish with varnish
6mm screw
FP3
125
Plan Furniture 2 DI
Scale 1 : 1 0
Detail I Not to scale
PVC Partition
Foam with fabric coated
FF4
Plan Seating 2
Steel base
DJ
Scale 1 : 1 0
Detail J Not to scale
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Detail Drawing I & J
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 3 4
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
Wood Round Stool
PRODUCED BY AN AUTODESK STUDENT VERSION
Wood Panel
Concrete Wall
Clading Bolt with plug Wood panel
SC2
DK
Wall Design Scale 1 : 1 0
Detail K \ plan
DK
Not to scale
Detail K \ Section Not to scale
Copyright 2020 RVICHI studio. ALL RIGHTS RESERVED Reproduction prohibited unless authorized in writing by RVICHI studio.
Integrated Hub:Terminal Design Kuala Lumpur Sentral, 50470 Kuala Lumpur, Federal Territory of Kuala Lumpur
Client
Kuala Lumpur Sentral Drawing Title
Detail Drawing K
Drawing Status
Tender Drawing Drawing No.
AAD 3 2 3 1 d 3 5
Drawn By
1 7 1 3 2 2 5 Muhammad Saifullah B. Za'ba Check By
IDr. Ts. Ismail Jasmani
Note The information contained in this document is copyright and may not be used or reproduced for any other project or purpose. Verify all dimensions and levels on site and report and discrepancies to RVICHI studio for direction prior to the commencement of work. Drawings are to be read in conjunction with all other contract documents. Use figured dimensions only. Do not scale from drawings. RVICHI studio cannot guarantee the accuracy content and format for copies of drawings issued electronically. The completion of the Issue Details Checked and Authorized section is confirmation of the status of the drawing. The drawing shall not be used for construction unless endorsed 'For Construction' and authorized for issue.
PRODUCED BY AN AUTODESK STUDENT VERSION
Project:
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
Concrete Wall