Architectural Portfolio 2021 | MSSS Sanathan | SPAV

Page 1


Index


Resume


SYNTAX: MIXED USE BUILDING

SHAKESPEARE SARANI RD, KOLKATA





SWASTHIKA: HERITAGE INTERPRETATION CENTER NAGARJUNAKONDA , TELANGANA





BUNA: WEAVER’S RESIDENCE TINGVONG, SIKKIM





1

3

2 5175

3600

4 4050

6

5 3511

7

1214

1

5099

3

2 5175

3600

4 4050

6

5 3511

1214

WORKING DRAWINGS FOR TINGVONG WEAVERS RESIDENCE

7 5099

C1 Footing Section 300

53

15

C2

C2

C1

A

100

C1

1500

A

1800

S5

S4

8550

8550

Scale 1:50

S6

Plinth Beam Section

Beam Section

C2

C1

B

C1

300

C1

S3

1800

230

230

8550

8550

300

1800

52

B

LEGEND

C2 Footing Section C

C1

C1

C1

S2

LEGEND

M.H

MAN HOLE

GULLY TRAP

D

C1

1800

C1

GREY WATER

G.T

Scale 1:50

C1

COLD WATER HOT WATER

Mixture & Shower Tap

8550

8550

100

S1 4170

D

Ablustion Tap

C

1500

C1

Floor Trap

230

230

COLD WATER HOT WATER

INSPECTION CHAMBER

GREY WATER

4170

1

3

2

4

5

6

7 SI NO

DESCRIPTION

LEGEND:

POSITION

CEILING MOUNTED LIGHT FIXTURE

TOWARDS THE WATER TREATMENT PLANT 3088

3896

I.C

6

SB 2

+1400mm FROM FFL

2

0

CEILING MOUNTED FLUORESCENT LIGHT FIXTURE

1

3

WALL BRACKET LIGHT POINT AT +2400mm FROM F.F.L.

3

SB 3

+1400mm FROM FFL

0

0

0

2

4

SB 4

+1400mm FROM FFL

1

0

1

4

5

SB 5

+1400mm FROM FFL

0

0

0

2

6A SOCKET

6

SB 6

+800mm FROM FFL

1

1

0

2

FAN REGULATOR.

7

SB 7

+1400mm FROM FFL

0

0

1

4

16A SOCKET

8

SB 8

+1400mm FROM FFL

0

0

0

2

SB 1

+1400mm FROM FFL

CEILING FAN. SWITCH BOARD. +1400 FROM F.F.L

G.T

757 1396 583

665 1421

1041

2453

1729

3982

WEST ELEVATION

SOUTH ELEVATION

9

SB 9

+1400mm FROM FFL

1

0

0

3

10

SB 10

+1400mm FROM FFL

0

0

1

2

TELEPHONE OUTLET. - AT +300 FROM F.F.L. INTERNET OUTLET. AC POINT AT 2400mm FROM FFL.

1585

740 mm

1

I.C

M.H

A

2785

2780

1650

1278

426

2820

A

750 mm

1

2

1

WATER FROM LOCAL SUPPLY

1

CABLE/TV OUTLET AT +300 FROM F.F.L. 2416

B

DRY AREA

2882

988

150

WATER CLOSET

FLOOR TRAP

658

4522

300

610

384

0

0

1

2

+800mm FROM FFL

1

1

0

2

13

SB 13

+800mm FROM FFL

1

1

0

2

14

SB 14

+1400mm FROM FFL

0

0

0

2

15

SB 15

+1400mm FROM FFL

0

0

0

2

16

SB 16

+800mm FROM FFL

1

0

1

3

17

SB 17

+800mm FROM FFL

1

0

1

3

SWITCH MAIN DISTRIBUTION BOARD M

METER BOARD

GENERAL NOTES Site Dimensions : 25000 mm by 20000 mm Offsets : 3000 mm at at East side and 1500 mm at the remaining 3 Sides. Column Thickness : 300 mm by 300 mm. Wall Thickness : 300 mm Exterior & 115 mm Interior ALL THE DIMENSIONS IN THE DRAWING ARE IN MM

WATER HEATER

1992

1130

730 mm

WET AREA

2114

2845

532

S1 - 5540 mm x 5640 mm S2 - 5540 mm x 5640 mm S3 - 5400 mm x 4940 mm S4 - 5540 mm x 4940 mm S5 - 5540 mm x 2140 mm S6 - 5540 mm x 3950 mm

1005

FLOOR TRAP

+1400mm FROM FFL

SB 12

LEGEND

580

SHOWER

SB 11

12

2729

978

C

208

ABLUTION TAP

11

D G.T

G.T

I.C

2662

A'

PLAN

1251

437

SECTION AA'

Reinforcement Bars - 12 mm (dia) & 8 mm (dia) Slab Depth - 150mm

I.C

M S S S SANATHAN 1180100752 B.ARCH 4TH YEAR SECTION A SCHOOL OF PLANNING AND ARCHITECTURE VIJAYAWADA

N


3

2

4

6

5

7

1

3

2

4

6

5

WORKING DRAWINGS FOR TINGVONG WEAVERS RESIDENCE

7

23899

4280

460

449

7899

600

263

7910

263

230

4981

4280

W1

W1

6000 619

619

750 mm 1068

SB 4

1270

300

4981

4981

BEAM 250X300MM

SB 2

750 mm

10800

SLAB 150MM THICK

SB 5

1029

4603

1204

283

D1 698

SB 3

1204

750 mm

D2

D1

1300

1854

4981

1075

4992

1064

331

406

6646

165

D1

460

1854

600

13110

1024

1025

LEGEND

600

600

601

6657

370

2408

370

600

22800

535

791

200

SB 7

B

791

LINTEL

SB 6

230

230

1905

1905

3099

500

BRICK WALL 300 mm

W1

B

Plinth Beam Section

Beam Section

7970

7101

1235

740 mm 7101

1204

241

D1

1235

PARAPET WALL 250MM THICK

9589

4981

600

9589

600

600

A

SB 1

276

A

300

1

LINTEL

4603

4981

Ablustion Tap

D2

1500

4981

Floor Trap W1

COLD WATER HOT WATER

Mixture & Shower Tap

0 mm 600 mm

2212

2212

750 mm

878

878

10796

WINDOW

SB 8

GREY WATER

3829

5700

600

525

1119

4981

1119

800

M.H

MAN HOLE

GULLY TRAP

D1 525

1316

1322

2408

600

2138

D1

4981

600

2408

600

370

413

1323

5700

601

6300 601

SB 11

600

C

PLINTH BEAM

6300

370

600

G.T

6300

6900

75MM PCC BED

FFL

4770

SB 10

3829

800

15 MM PLASTERING

DISTRIBUTION BOX

C

LEGEND

1204

W2

463

12 MM PLASTERING

84

SB 9

4981

W1

W1

750 mm

SECTION OF EXTERIOR WALL

988

2408

D1

2408

888

524

D1

658

12000

758

524

750 mm

COLD WATER HOT WATER

INSPECTION CHAMBER

GL

SB 15

12000

SB 14

4981

SB 13

SB 12

GREY WATER

5294

5294

6030

5800

740 mm

5800

5800

5218

5218

6030

740 mm

5800

SCALE 1:20

SI NO W1

D

1826

4981

50

320

3259

801

1818

600

4293

600

4301

4981

1818

GROOVES FOR GRIP 300

600

SUNSHADE 500

BALUSTER

225

2500

BOLTED AT BASE

HEAD

JAMB

1463

Detail A

BRICK WAIST SLAB 12 MM PLASTERING

Detail A

2955

1500

1700

1700

STILE

1778

800

Detail B

CASING

75

SILL BEAM

BRICK WALL

3494

3496

902

150

22

FFL

600

PLAN

A' UP

SASH

GLASS

18

DW 17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

BEADING

INTERNAL PLASTER 12mm thick

30mm

12 mm

BRICK WALL 300 mm thick

2

0

CEILING MOUNTED FLUORESCENT LIGHT FIXTURE

1

3

WALL BRACKET LIGHT POINT AT +2400mm FROM F.F.L.

3

SB 3

+1400mm FROM FFL

0

0

0

2

4

SB 4

+1400mm FROM FFL

1

0

1

4

5

SB 5

+1400mm FROM FFL

0

0

0

2

6A SOCKET

6

SB 6

+800mm FROM FFL

1

1

0

2

FAN REGULATOR.

7

SB 7

+1400mm FROM FFL

0

0

1

4

16A SOCKET

8

SB 8

+1400mm FROM FFL

0

0

0

2

+1400mm FROM FFL

PLAN

9

SB 9

+1400mm FROM FFL

1

0

0

3

10

SB 10

+1400mm FROM FFL

0

0

1

2

CEILING FAN. SWITCH BOARD. +1400 FROM F.F.L

TELEPHONE OUTLET. - AT +300 FROM F.F.L. INTERNET OUTLET.

11

SB 11

+1400mm FROM FFL

0

0

1

2

12

SB 12

+800mm FROM FFL

1

1

0

2

13

SB 13

+800mm FROM FFL

1

1

0

2

14

SB 14

+1400mm FROM FFL

0

0

0

2

15

SB 15

+1400mm FROM FFL

0

0

0

2

16

SB 16

+800mm FROM FFL

1

0

1

3

17

SB 17

+800mm FROM FFL

1

0

1

3

SWITCH MAIN DISTRIBUTION BOARD M

METER BOARD

GENERAL NOTES Site Dimensions : 25000 mm by 20000 mm Offsets : 3000 mm at at East side and 1500 mm at the remaining 3 Sides. Column Thickness : 300 mm by 300 mm. Wall Thickness : 300 mm Exterior & 115 mm Interior ALL THE DIMENSIONS IN THE DRAWING ARE IN MM

+400

Reinforcement Bars - 12 mm (dia) & 8 mm (dia) Slab Depth - 150mm

1

30mm 6mm 2500

STILE

FFL

225

A 3000

SECTION X - X' 50

+1400mm FROM FFL

S1 - 5540 mm x 5640 mm S2 - 5540 mm x 5640 mm S3 - 5400 mm x 4940 mm S4 - 5540 mm x 4940 mm S5 - 5540 mm x 2140 mm S6 - 5540 mm x 3950 mm

900

100mm

6

SB 2

SB 1

LEGEND

SECTION AA' CASING

1

CABLE/TV OUTLET AT +300 FROM F.F.L.

20 MM THICK MARBLE

MUTIN BAR

GLASSS PANNEL

1

AC POINT AT 2400mm FROM FFL.

NOSING

RAIL

1

2

1 600

INT. PLASTER HEAD

LEGEND:

POSITION

CEILING MOUNTED LIGHT FIXTURE

4981

24000

ELEVATION

DESCRIPTION

W1 3370

693

600

SB 17

SB 16

4981

600

D

1826

Detail B

M S S S SANATHAN 1180100752 B.ARCH 4TH YEAR SECTION A SCHOOL OF PLANNING AND ARCHITECTURE VIJAYAWADA

N


DVARA BHANDAM: CARPENTRY DEVELOPMENT CENTER ARAKU VALLEY, ANDHRA PRADESH













End Page


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.