About Us NINGBO SANHE REFRIGERATION CO., LTD. was established in 1998 to supply spare parts for HVAC/R industry. Over the past years, NINGBO SANHE has earned its reputation as the leading supplier among customers due to its experience, professionalism and integrity. Dedicated NINGBO SANHE team attends to each customer’s specific requirements and helps customers make informed buying decisions.

Our Mission NINGBO SANHE will use wide knowledge in products and services, to supply the most suitable refrigeration parts and system solution to our customer.

Our Vision NINGBO SANHE is committed to providing the best services and meeting the needs of businesses through reliable quality, competitive price, and repid delivery. Our hope is to be the most professional One-Stop HVAC/R parts and system solution supplier.

A


Our Factory

Certification

www.sanhehvac.com

B


CONTENTS

01

SINGLE PRESSURE CONTROL

01

02

Single Pressure Control

DOUBLE PRESSURE CONTROL

EXPANSION VALVE

18

ST2/STE2 Thermal Expansion Valve

19

NRF(E)/RT(E) Series Expansion Valve

20

TCLE/TRFE Series Expansion Valve

21

TB Series Expansion Valve

02

Double Pressure Control

03

Delay Time Differential Pressure Control

03

Differential Pressure Control

22

04

SH55/58 Pressure Control

22

Electronic Expansion Valve

22

CGX Series Bypass Valve

23

CBX Series Bypass Valve

05

THERMOPLASTIC CAPILLARY

HOSE

BYPASS VALVE

24 25

ELECTRONIC-DRAIN VALVE

06

SIGHT GLASS

FILTER DRIER

SGS Series

25

SEK Molecular Sieve Liquid Line Filter Drier

06

SGN Series

26

SDK Solid Core Liquid Line Filter Drier

06

SG Series

27

SDCL/SDML Liquid Line Solid Core Drier

29

Two-Way Filter Drier

30

Oil Filter

30

SSF Suction Line Filter Drier

06

07

VALVE

07

BV Series Ball Valve

08

Standard Ball Valve

31

09

Hand Valve

CYLINDER

10

Magnetic Check Valve

31

Dry And Suction Filter Cylinder

11

Plunger Check Valve

32

Drying & Suction Drier-Filter Core

11

Globe Valve

32

D/H Drier-Filter Cores

12

Rotalock Valve

32

X Suction Line Filter Cores

Split Valve

32

SX Suction Oil Filter Cores

32

Mounting Brasket For Demountable Shells

13

14

VIBRATION ABSORBER TUBE

14

15

Vibration Absorber Tube

SOLENOID VALVE

C

18

33

DRY AND SUCTION FILTER

SUCTION LINE ACCUMULATOR

33

Suction Line Accumulator

35

Heat Exchanger Accumulator

15

SH Series Solenoid Valve

16

EVR Solenoid Valve

36

17

SHF Improved Solenoid Valve

36

Conventional Oil Separator

17

FDF Series Solenoid Valve

37

Demountable (Flange) Oil Separator

38

Mechanical Oil Level Regulator

OIL SEPARATOR


39

LIQUID RECEIVER

39

Vertical Liquid Receiver

43

Horizontal Liquid Receiver

44

OIL RECEIVER

44

45

Oil Receiver

SHELL & TUBE HEAT EXCHANGER

45

46

Shell & Tube Heat Exchanger

NOTE

www.sanhehvac.com

D


SINGLE PRESSURE CONTROL

• Scale plate use “bar” & “psig” units • Could be use “MPa” , “ kgf/cm2” units also as customer requirement. • Connection could as customer requirement use British unit flare(E), solder(S) and capillary(C)such as SHP506E; • Ammonia refrigerant model added a code B, such as SHP506B.

Rated voltage(V) Rated Amps(A) Non-Inductive Current Full Load Current Inductive Current Locked Roter

01

125V AC

250V AC

24V DC

20A 15A 72A

10A 8A 72A

10A 8A 64A

Differential Pressure (bar)

Factorly Setting (bar) Fig.1 Fig.2 1 0.5

Max.Bellows Press (bar)

Model

Pressure Range (bar)

SHP502

-0.5 ~ 2

0.2 ~ 0.7

SHP503

-0.5 ~ 3

0.35 ~ 1.5

2

1

16.5

SHP506

-0.5 ~ 6

0.6 ~ 4

3

2

16.5

SHP506M

-0.5 ~ 5.5

≤1

Manual Reset

2

16.5

SHP110

1 ~ 10

1~3

6

5

16.5

SHP516

5 ~ 16

2~5

10

8

33

16.5

SHP520

5 ~ 20

2~5

16

14

33

SHP530D

5 ~ 30

3 ~ 10

20

15

33

SHP530

8 ~ 30

3 ~ 5 ( Fixation )

20

15 ~ 17

33

SHP530M

8 ~ 30

≤5

20

Manual Reset

33


DOUBLE PRESSURE CONTROL

• Maximum bellows testing pressure: Low 16.5 bar, high 33 bar; • Scale plate use “bar” & “psig” units • Could be use “MPa” , “ kgf/cm2” units also as customer requirement. • Connection could as customer requirement use British unit flare(E), solder(S) and capillary(C)such as SHP830E; • Ammonia refrigerant model added a code B, such as SHP830B.

RANG E AC 250V-8A AC 125V-15A

bar

30 25 20 15 10 8

PSi

435 363 290 218 145 115

M.W.P 33bar/471psig

Rated Voltage(V) Rated Amps(A) Non-Inductive Current Full Load Current Inductive Current Locked Roter Low pressure(bar) Model

125V AC

250V AC

24 V DC

20A 15A 72A

10A 8A 72A

10A 8A 64A

High Pressure(bar)

Reset Pressure (bar)

Factory Setting (bar) Low Pressure

High Pressure

Pressure Range

Differentral Pressure

Pressure Range

Differential Pressure

Low Pressure

High Pressure

Fig.1

Fig.2

Fig.1

Fig.2

SHP830

-0.5 ~ 6

0.6 ~ 4

8 ~ 30

3 ~ 5 (Fix)

Auto

Auto

3

2

20

15

SHP830HM

-0.5 ~ 6

0.6 ~ 4

8 ~ 30

≤5

Auto

Manual

3

2

20

Manual Reset

SHP830HLM

-0.5 ~ 5.5

≤1

8 ~ 30

≤5

Manual

Manual

Manual Reset

2

20

Manual Reset

Note: Maximum bellows testing pressure: Low 16.5 bar, high 33 bar, Scale plate use “bar” & “psig” units ; Could be use “MPa” , “ kgf/cm2 ” units also as customer require. Connection could as customer require use British unit flare(E), solder(C) and capillary(S), such as SHP830E; Ammonia refrigerant model added a code B, such as SHP8308.

www.sanhehvac.com

02


DIFFERENTIAL PRESSURE CONTROL

Features • Differential pressure is adjustable type; • Model Options: controlling throughput of condensed water and cotrolling compressor oil pressure protection; • Non-delay devices of differential pressure control.

Inductive Current

Rated Voltage(V) Rated Amps(A) Non-Inductive Current Full Load Current Locked Roter Differential Adjust Range (bar) 0.5 ~ 2 0.5 ~ 3.5 0.5 ~ 3.5 1~6 1~6

Model SHD502 SHD504 SHD504H SHD106 SHD106H

Factory Setting (bar) 0.5 1 1 1 1

125V AC

250V AC

24 V DC

20A 15A 72A

10A 8A 72A

10A 8A 64A

Max. Working Pressure (bar) 17 17 30 17 30

Description Micro differential -----

Scale boards use “bar·, and “psig” two kinds of measurement units; Can be according to the customer requires use “MPa”, “kgf/cm2 ” Measurement units. Interface based on customer require: Inch screw type. add “E”, type welding model added “c”, capillary model added “s” such as SHD106E. Ammonia refrigerant type in the model. add “s”. shch as SHD106B

DELAY TIME DIFFERENTIAL PRESSURE CONTROL SHD series of delay differential pressure control is a protection controller, which can effectively protect the compressor oil pressure and always maintain a high-pressure state to avoid the damage of the compressor crankshaft due to the oil shortage; lf the oil pressure does not reach the set value within the set time, the controller will immediately cut off the power and stop compressor.

Rated Voltage (V)

125V AC

250V AC

24V DC

Non-Inductive Current

20A

10A

10A

Full Load Current

15A

8A

8A

Locked Roter

72A

72A

64A

Inductive Current

03

Model

Pressure Adjust Range (bar)

Switch Difference

Factory Setting (bar)

Delay Time

Max. Working Pressure (bar)

SHD35T

0.5 ~ 4

≤0.4

1

60s / 90s

16.5

SHD35TH

0.5 ~ 4

≤0.4

1

60s / 90s

33


SINGLE PRESSURE CONTROL

SH55 Series pressure switches are used to control the pressure of compressor in refrigerant system, also available in air or water fluid. This series have quite stable performance with internal micro-switch structure. Standard mounting bracket are provided

Rated Voltage (V) Full Load Current Inductive Current Locked Roter Temperature

125V AC 20A 72A

Range (bar)

Model

Min -0.2 2 8 8

SH5508 SH5514 SH5532 SH5542

250V AC 10A 72A -20 ~ 110ยบC

Differential (bar) Min Max 0.7 4 1 4 2 6 4 10

Max 7.5 14 32 42

24V DC 8A 64A

Factory Setting (bar) OFF ON 6 2 10 8 20 17 30 25

Max Operating Pressure (bar) 20 20 35 46.5

DOUBLE PRESSURE CONTROL Contact Function

Arrow means the direction of pressure increasing, M means hand reset

Rated Voltage (V) Full Load Current Locked Roter Temperature

Inductive Current

Model SH5832

SH5832HM

SH5832HLM

D 250V AC 50VA 4A

24V DC 8A 64A -20 ~ 110ยบC

Min

Range (bar) Max

Low Side

-0.2

7.5

High Side

8

32

Low Side

-0.2

7.5

High Side

8

32

Low Side

-0.2

High Side

8

Pressure Side

B-C 250V AC 10A 72A

125V AC 20A 72A

Differential (bar) Min Max 0.7

4

Factory Setting (bar) OFF ON

Max Operating Pressure (bar)

4

2

20

20

15

35

4

2

20

Fixed 4

20

Manual Reset

35

7.5

Fixed 4

3

Manual Reset

20

32

Fixed 4

20

Manual Reset

35

Fixed 4 0.7

4

www.sanhehvac.com

04


THERMOPLASTIC CAPILLARY HOSE

Features • • • • •

High elasticity No more brazing, flaring and bending of copper tubes. Time saving for system installation and assembling. Protection class IP65, insulation class H level. Very low refrigerating gas permeation rate.

Assembly Instructions

1

2

3

4

5

6

1. Cut the hose using proper shears,automatic or manual cutters.The cut must be per fectly square and smooth. 2. Insert the sleeve on the hose with the groove towards the hose side to be assembled 3. Insert the nut onto the hose. 4. Push the insert inside the hose 5. Make the nut slide onto the external part of the insert(flare) and push the sleeve till it covers the bottom of the free insert. 6. Assemble the hose by positioning manual pliers on the sleeve covering its whole surface. Crimp till hand pliers poen automatically.A second crimping is useful to obtain a safer assembling.

Fittings and Accessories

90%insert with nut

Straight insert with nut

T fitting

Copper gasket

Straight insert

Sleeve

Note: Available in any combination of 1/4" or 3/8" brass SAE flare straight or 90° angel fittings.

Thermoplastic Hose ID 2mm Model

Colour

Inner Diametre

Outer Diametre

Tolerances

Min Bending Radius

Working Pressure

Working Temp

Weight

TCH2 TCH2-B TCH2-R

Black Blue Red

2.0 mm 2.0 mm 2.0 mm

5.9 mm 5.9 mm 5.9 mm

0.1 mm 0.1 mm 0.1 mm

10 mm 10 mm 10 mm

45 bar 45 bar 45 bar

-40ºC ~ 130ºC -40ºC ~ 130ºC -40ºC ~ 130ºC

30 g/m 30 g/m 30 g/m

Thermoplastic Hose ID 4mm

05

Model

Colour

Inner Diametre

Outer Diametre

Tolerances

Min Bending Radius

Working Pressure

Working Temp

Weight

TCH4 TCH4-B TCH4-R

Black Blue Red

4.0 mm 4.0 mm 4.0 mm

8.2 mm 8.2 mm 8.2 mm

0.1 mm 0.1 mm 0.1 mm

35 mm 35 mm 35 mm

45 bar 45 bar 45 bar

-40ºC ~ 130ºC -40ºC ~ 130ºC -40ºC ~ 130ºC

50 g/m 50 g/m 50 g/m


SIGHT GLASS

Model SGS-7 SGS-9 SGS-11 SGS-13 SGS-17 SGS-33

Connector Specification 7/8" ODM 1-1/8" ODM 1-3/8" ODM 1-5/8" ODM 2-1/8" ODM 4-1/8" ODM

Rn (mm)

Model

11 14.2 17.5 20.64 27 52.4

SGS-S13U

Window Connected Screw Diameter(mm) 24 1-5/8”-12UNF

SGS-S10U

19

SGS-S14U

27

1-1/4”-12UNF 1-3/4”-12UNF

SGS-S18U

36.3

2-1/4”-12UNF

SGS-S22U

44.5

2-3/4”-12UNF

Male SAE to Male SAE Model SGN-2 SGN-3 SGN-4 SGN-5 SGN-6

Connector Specification 1/4" SAE 3/8" SAE 1/2" SAE 5/8" SAE 3/4" SAE

L (mm) 64 70 78 78 94

H (mm) 23 24 28 29 32

B (mm) 7/16"-20UNF 5/8"-18UNF 3/4"-16UNF 7/8"-14UNF 1-1/16"-14UNF

L (mm) 65 65 70 80

H (mm) 23 24 30 32

B (mm) 7/16"-20UNF 5/8"-18UNF 3/4"-16UNF 7/8"-14UNF

Male SAE to Female SAE Model SGN-2FS SGN-3FS SGN-4FS SGN-5FS

Connector Specification 1/4" MxF 3/8" MxF 1/2" MxF 5/8" MxF

Female ODS to Female ODS Model SGN-2S SGN-3S SGN-4S SGN-5S SGN-6S SGN-7S SGN-9S

Connection Specification 1/4" (06mm) 3/8" (10mm) 1/2" (12mm) 5/8" (16mm) 3/4" (18mm) 7/8" (22mm) 1-1/8" (28mm)

L (mm) ODS ODS ODS ODS ODS ODS ODS

L1 (mm) 100 118 145 145 160 172 172

H (mm) 23 23 28 29 32 40 40

A (mm) 6.35 (6) 9.52 (10) 12.7 (12) 15.88 (16) 19.05 (18) 22.22 (22) 28.57 (28)

Male SAE to Male SAE Model SG-2 SG-3 SG-4 SG-5 SG-6

Connector Specification 1/4" SAE 3/8" SAE 1/2" SAE 5/8" SAE 3/4" SAE

L (mm) 58 70 80 80 90

H (mm) 23 28 31 34 34.3

B (mm) 7/16"-20UNF 5/8"-18UNF 3/4"-16UNF 7/8"-14UNF 1-1/16"-14UNF

Female ODS to Female ODS Model SG-2S SG-3S SG-4S SG-5S SG-6S SG-7S

Connector Specification 1/4"(06mm) ODS 3/8"(10mm) ODS 1/2"(12mm) ODS 5/8"(16mm) ODS 3/4"(18mm) ODS 7/8"(22mm) ODS

L (mm) 100 120 124 124 140 160

L1(mm) 8 10 12 14 14 15

H (mm) 23 28 31 33 34.3 46

A (mm) 6.35 (6) 9.52 (10) 12.7 (12) 15.88 (16) 19.05(18) 22.22(22)

www.sanhehvac.com

06


BV SERIES BALL VALVE

Features • • • • • • • • •

L1

No pressure drop in flow. Only turn 1/4 circle to make valve full open or full close. Turning stop for full open or full close. Two-direction flow is available. Argon arc welded structure. Explosion-proof valve stem design. Modified PTFE sealing. Inside liquid accumulation is avoided. Could be mounted on the control panel.

L

Specification Appicable Refrigerant Appicable Medium Temperature (PS/MWP) Max. Opening Pressure Max. Allowable Pressure Yearly leakage of Refrigerant Certification

CFC . HCFC. HFC. HC -40ºC ~ +150ºC 45bar (653psig) 65bar (943psig) ≤ 2g R22/a UL

Type

Connection Size(in)

L (mm)

L1 (mm)

Type

Connection Size(in)

L (mm)

L1 (mm)

BV-06

1/4"

144

7

BV-06S

1/4"

144

7

BV-10

3/8"

144

8

BV-10S

3/8"

144

8

BV-12

1/2"

160

11

BV-12S

1/2"

160

11

BV-16

5/8"

160

15

BV-16S

5/8"

160

15

BV-18

3/4"

186

20

BV-18S

3/4"

186

20

BV-22

7/8"

186

20

BV-22S

7/8"

186

20

BV-28

1-1/8"

214

23

BV-28S

1-1/8"

214

23

BV-35

1-3/8"

248

25

BV-35S

1-3/8"

248

25

BV-42

1-5/8"

280

28

BV-42S

1-5/8"

280

28

BV-54

2-1/8"

304

33

BV-54S

2-1/8"

304

33

BV-67

2-5/8"

305

37

BV-67S

2-5/8"

305

37

BV-79

3-1/8"

380

40

BV-79S

3-1/8"

380

40

BV-89

3-1/2"

410

40

BV-89S

3-1/2"

410

40

BV-92

3-5/8"

410

40

BV-92S

3-5/8"

410

40

Two types of BV ball valve are available :with and without the charging port . The part number which with “’s” has the charging port.

07


STANDARD BALL VALVE

Features • • • • • • • • •

No pressure drop in flow. Only turn 1/4 circle to make valve full open or full close. Turning stop for full open or full close. Two-direction flow is available. Argon arc welded structure. Explosion-proof valve stem design. Modified PTFE sealing. Inside liquid accumulation is avoided. Could be mounted on the contral panel.

Specification Appicable Refrigerant

CFC . HCFC. HFC. HC

Suitable Temperature

-40ºC ~ +140ºC

The Maximum Working Air Pressure

4.5 Mpa

Hydraulic Pressure

6.8 Mpa

Certification

UL

Model

ODS

ΦD

B

H

L

Standard

With a Chargeing Port

inch

mm

mm

mm

mm

SH-17202

SH-17402

1/4"

SH-17203

SH-17403

3/8"

Φ10

10

28.5

126

SH-17204

SH-17404

1/2"

SH-17205

SH-17405

5/8"

SH-17206

SH-17406

3/4"

Φ13

12

30.5

150

SH-17207

SH-17407

7/8"

SH-17209

SH-17409

1-1/8"

Φ18.5

20

40.5

189

SH-17211

SH-17411

1-3/8"

SH-17213

SH-17413

1-5/8"

Φ31

25

51

245

SH-17217

SH-17417

2-1/8"

Φ48

30

64.5

319

SH-17221

SH-17421

2-5/8"

Φ58

35

81.5

380

SH-17225

SH-17425

3-1/8"

Φ71

91.5

410

SH-17233

SH-17433

4-1/8"

Φ94

115

450

40

www.sanhehvac.com

08


HAND VALVE

Hand valve is one kind of manual stop valve and applied to one-way flow.It is used for the liquid of freezing, refrigeration and air conditioning systems and also installe in inhaling &heating pipes.

Features • With nylon valve core, durable sealing surface,long service life. • With a stainless steel diaphragm which can avoid leaking during service life. • Applicable refrigerant medium: For R22, R134A, R410A, R502, R407C etc. • Medium temperature:-25°C ~ +100°C • Maximum working pressure:4.5MPa • Just turn one and a half circle to make the valve full open or full closed.

Specification Model SH-B-02H SH-B-02 SH-B-03H SH-B-03 SH-B-04H SH-B-04 SH-B-05H SH-B-05 SH-B-06H SH-B-06 SH-B-07H SH-B-07

09

Specification 1/4" 3/8" 1/2" 5/8" 3/4" 7/8"

Connection Thread

Dimension(mm) B

C

ODF

60

6

SAE

58

13

ODF

52

5.5

SAE

60

13

D

E

66

35

84

41.3

ODF

80

6

SAE

81

17

ODF

82

7.5

SAE

84

17

ODF

85

8.5

SAE

87

17.4

ODF

83

12.4

84

41.3

SAE

105

24

110

50


MAGNETIC CHECK VALVE CV type magnetic check valve is designed with a permanent magnet, and a diaphragm with steel core, which has coated with modified NBR on surface. The diaphragm is compatible to many refrigerants and has a perfect sealing performance. The valve can be used in liquid line and exhaust line of compressor, and can be mounted with any angel due to its special design.

Features • • • • • • • • • • • •

Multi orientation while maintaining flow direction Hermetic spun copper body design Designed for maximum flow and minimal pressure drop Valve diaphragm coated with Neoprene Built-in 30 mesh stainless steel screen Copper connection sizes 1 /4” through 3-1 /8” Stable, Zero leak Negligible loss in system efficiency Efficient sealing with a negligible leak rate Able to be installed in any position Filt function to extend the valve service life Suitable for a wide range of applications, including combination (muffler/check valve)

Model

ConnectorSize (A)

Shell Body (C)

Length (B)

Mesh No.

SWP(Kpa)

Leakage Rate @420 kPa (cm3/sec)

Kv(m3/Hr)

CV-04

1/4

22

102

30

5500

<0.00025

0.47

CV-06

3/8

22

102

30

5500

<0.00025

0.99

CV-08

1/2

22

102

30

5200

<0.00056

0.99

CV-08B

1/2

29

127

30

5200

<0.00056

2.67

CV-10

5/8

22

102

30

5200

<0.00056

2.98

CV-10B

5/8

29

127

30

5200

<0.00056

2.98

CV-12

3/4

29

127

30

4100

<0.00123

5.56

CV-12B

3/4

41

178

30

4100

<0.00123

5.56

CV-14

7/8

29

127

30

4100

<0.00123

7.58

CV-14B

7/8

41

178

30

4100

<0.00123

7.58

CV-18

1-1/8

41

213

30

4100

<0.00203

13.19

CV-18B

1-1/8

54

213

30

4100

<0.00203

13.19

CV-22

1-3/8

54

213

30

4000

<0.00287

16.26

CV-26

1-5/8

54

213

30

3000

<0.00453

27.78

CV-34

2-1/8

92

305

30

3200

<0.00643

48.27

CV-42

2-5/8

105

330

30

3000

<0.00853

64.76

CV- 50

3-1/8

105

330

30

3000

<0.00995

80.95

www.sanhehvac.com

10


PLUNGER CHECK VALVE Features • Max. working pressure: 4.8MPa. • Working media: R22, R134a, R410a, POE refrigerant oil, water, steam and fluorine refrigerants. • Working temperature: -40ºC ~ +150ºC • Small size, easy to mount/unmount. • Good anti-vibration and sealing performance, easy to use. • Sealed by imported PTFE: good sealing performance and long durability.

Model

ODS (inch.)

SH-3120/6 SH-3120/7 SH-3120/9 SH-3120/11 SH-3120/13 SH-3120/17

3/4" 7/8" 1-1/8" 1-3/8" 1-5/8" 2-1/8"

DN (mm) Φ25 Φ32 Φ38 Φ48

B (mm) 18 20 22 25 30

H (mm)

M (mm)

27 34.5 37 42

M10

L (mm)

C (mm)

100

86

118 141 172

103 127 137

Note: The valve should be mounted according to the flow direction marked on the valve body.

GLOBE VALVE Globe valve could be installed in commercial refrigeration system, civil and industrial air-conditional systems. The spindle is automatic closed,it can be installed in any position which needs to change the direction.

Features • Vlave plate of polyamide nylon to give complete shutoff with minimum torque. • Valve handle with special design,can be shut-off without the use of tools. • Adapt to R22,R502,R134a,R407C,R410,R404a,R600a refrigerants and so on. • Maximum working prossure: 4.5Mpa(Air); 6.8Mpa (Hydraulic) • Working temperature: -40ºC ~ +140ºC

Model

ODS (inch.)

SH-6510/7 SH-6510/9 SH-6510/11 SH-6510/13 SH-6510/17

7/8" 1-1/8" 1-3/8" 1-5/8" 2-1/8"

DN (mm) Φ25 Φ32 Φ38 Φ48

B (mm)

H (mm)

20 22 25 30 30

27

Note: The valve should be mounted according to the flow direction marked on the valve body.

11

34 37 42

M (mm)

M10

L (mm)

C (mm)

100

132

118 141 172

140 160 174


ROTOLOCK VALVE

ODS

Model

Inch 3/8" 1-1/8" 1-3/8" 3/4" 7/8" 1/2" 7/8" 5/8" 5/8"

MLV01 MLV02 MLV03 MLV04 MLV05 MLV06 MLV07 MLV08 MLV09

mm 10 28 35 19 22 12 22 16 16

ODS

Model

Inch 3/8" 1-1/8" 1-3/8" 3/4" 7/8" 1/2" 7/8" 5/8" 5/8"

TKV01 TKV02 TKV03 TKV04 TKV05 TKV06 TKV07 TKV08 TKV09

Body 20

30

35

45

mm 10 28 35 19 22 12 22 16 16

Model

Rotolack Connection

Hex

Body

Length

1" -14UNS 1-3/4" 12UN 1-3/4" 12UN 1-1/4 " 12UNF 1-1/4 " 12UNF 1" -14UNS 1-3/4 " 12UNS 1" -14UNS 1-1/4 " 12UNF

30 50 50 36 36 30 50 30 36

20 X 20 35 X 35 35 X 35 30 X 30 30 X 30 20 X 20 30 X 30 20 X 20 20 X 20

135 195 195 160 160 135 160 135 135

Rotolack Connection

Hex

Body

Length

1" -14UNS 1-3/4" 12UN 1-3/4" 12UN 1-1/4 " 12UNF 1-1/4 " 12UNF 1 " 14UNS 1-3/4 " 12UNS 1 " 14UNS 1-1/4 " 12UNF

30 50 50 36 36 30 50 30 36

20 X 20 35 X 35 35 X 35 30 X 30 30 X 30 20x20 30x30 20x20 20x20

105 173 175 135 135 110 135 110 110

ODS

Length (L)

ML001 ML002 ML003 ML004 ML005 ML006 ML007 ML008 ML009 ML010

inch 3/8" 1/2" 5/8" 3/4" 7/8" 1-1/8" 1-1/8" 1-3/8" 1-5/8" 1-3/8"

mm 10 12 16 19 22 28 28 35 42 35

ML011

1-5/8"

42

192

ML012

2-1/8"

54

194

105 109 105 135 135 172 172 190 192 190

www.sanhehvac.com

12


SPLIT VALVE Split valve is an important part of the split air conditioner, which is used for connecting the outdoor unit and the indoor unit. closing or openning the refrigerant circuit, extracting or fiIling refrigerant.

Features

Applicable Scope

• It is used to connect the outdoor units and indoor units, and play the role of switching. • Easy to operate, easy operation. • Use soft seal and hard seal to ensure the sealing performance.

• Applicablemedium: R22 , R134a, R410a, R407C, R32,etc. • Maximum working pressure: 4.2MPa. • Applicable medium temperature: -30ºC ~ +120ºC.

Model SV-01 SV-02 SV-03 SV-04 SV-05 SV-06 SV-07

Model SV-01B SV-02B SV-03B SV-04B SV-05B SV-06B

Model SV-02C SV-03C SV-04C SV-05C SV-06C SV-07C

Model SSV-03 SSV-04 SSV-05 SSV-06 SSV-07

13

Connection Size (in) 1/4" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8"

Connection Size (in) 1/4" 1/4" 3/8" 1/2" 5/8" 3/4"

Connection Size (in) 1/4" 3/8" 1/2" 5/8" 3/4" 7/8"

Connection Size (in) 3/8" 1/2" 5/8" 3/4" 7/8"

Remark Two Way

Three Way

Remark Two Way

Three Way

Remark

Three Way

Remark

Three Way


VIBRATION ABSORBER TUBE Metal hose, with excellent flexibility and vibration absorbing capacity due to being tightly covered by high intensitve protecting metal braid and fixed with two metal rings,then welded with copper socket, is used for connection between circulating tube and compressors of air-conditioners, refrigerators, congealers etc. to absorb vibration caused by the compressors and protect the whole tube system.

Features • • • •

Compatible with all CFC, HCFC and HFC refrigerants and oils. 100% leakage tested. Solid copper contruction. CE & UL certified.

Material Specification Item VA-014 ~ VA-418

Flexible Tubing SS304/ SS316/ Copper

Wire braid

Ferrule

Tube End

SS304/ SS316

SS304/ SS316/ Copper

SS304/ SS316/ Copper

Note:(1)Commonly used materials of our Vibration Absorber: Flexible Tubing:SUS304; Wire Braid:SUS304; Ferrule:SUS304; Tube End:Copper TP2; (2)If other materials are needed(except ones in the table above), please kindly specify in advance.

Specifications ETL Certificated Dimensions ( inch ) E

Working Pressure(psig)

Burst Pressure(psig)

200mm

1/2"

650

3250

8-1/2"

217mm

1/2"

650

3250

7-1/4"

9"

228mm

1/2"

650

3250

15/16"

8"

9-7/8"

250mm

7/8"

650

3250

3/4"

1/4"

8-1/16"

10-1/2"

268mm

7/8"

650

3250

VA-078

7/8"

1-3/8"

9-1/4"

12"

305mm

7/8"

650

3250

VA-100

1"

1-3/4"

9-7/16"

13"

332mm

7/8"

650

3250

VA-118

1-1/8"

1-3/4"

9-7/16"

13"

332mm

7/8"

650

3250

VA-138

1-3/8"

2-1/16"

11-7/16"

15-1/2"

395mm

7/8"

550

2750

VA-158

1-5/8"

2-1/4"

12-3/8"

16-15/16"

429mm

1"

510

2550

VA-218

2-1/8"

2-11/16"

15-3/16"

20-1/2"

524mm

1-3/8"

400

2000

VA-258

2-5/8"

3-1/16"

18"

24-1/8"

617mm

2"

350

1750

VA-318

3-1/8"

3-7/16"

20"

26-15/16"

684mm

2"

320

1600

VA-358

3-5/8"

4-1/16"

24"

32-1/8"

818mm

2"

190

570

VA-418

4- 1/8"

4-1/2"

24"

33"

836mm

2"

190

570

Model

A

B

C

D

VA-014

1/4"

1/2"

6-1/2"

7-7/8"

VA-038

3/8"

3/4"

7"

VA-012

1/2"

7/8"

VA-058

5/8"

VA-034

www.sanhehvac.com

14


SH SERIES SOLENOID VALVE Features • Only NC type solenoid valve is available. • It is applicable to various applications in freezing, cold storage and air conditioner units. • The solenoids of different power supply are available. • The thread capped solenoid is easy to be manually mounted and dismounted. • SH series solenoid valve is a direct-operated or servo-operated valve, which is applicable to one direction flow. • The valve seat of SH series solenoid valve is well sealed with perfect sealing performance. • Various voltage options are for solenoid while the valve body is universal. • Both integrated and separated SH series solenoid valves are available.

Applicable Refrigerant

HCFC and HFC (Customer choice)

Applicable Medium Temperature

-25ºC ~ +105ºC

Max. Operating Pressure

3.0MPa

Min. Pressure Differential to Open Valve

Direct-operated: 0.00MPa; Servo-operated: 0.02MPa

Max. Operating Pressure Differential ( MOPD)

2.5MPa

Applicable Ambient Temperature for Solenoid

-25ºC ~ +60ºC

Standard Voltage of Solenoid

AC380V, AC220V/50Hz(Custom-design is available)

Allowable Voltage Fluctuation for Solenoid

+10%--15%

Solenoid Coil

8W

Connection Model

15

Nominal Refrigerating Capacity kW (liquid)

Flare

Welded

SH-1020/2

1/4" SAE

--

SH-1028/2

--

1/4" ODF

SH-1020/3

3/8" SAE

--

SH-1028/3

--

3/8" ODF

SH-1064/3

3/8" SAE

--

SH-1068/3

--

3/8" ODF

SH-1064/4

1/2" SAE

--

SH-1068/4

--

1/2" ODF

SH-1068/5

--

5/8" ODF

SH-1070/4

1/2" SAE

--

SH-1078/4

--

1/2" ODF

SH-1070/5

5/8" SAE

--

SH-1078/5

--

5/8" ODF

SH-1078/6

--

SH-1098/7

--

Kv ( m3/h)

R22

HFC-134a

R404a/R502

0.175

3.15

2.95

2.08

0.230

4.15

3.90

2.75

0.800

14.5

13.50

9.50

0.800

14.5

13.50

9.50

2.200

39.6

37.10

26.20

2.610

47.00

44.00

31.00

3/4" ODF

4.300

77.50

72.045

51.10

7/8" ODF

5.700

102.60

96.00

67.85


EVR SOLENOID VALVE Features • Only NC type solenoid valve is available. • 100-mesh filter is contained at the suction end, which is replaceable. • (MOPD) is 3.0 MPa. • It is applicable to various applications in freezer, cold store and air conditioning unit. • It is applicable to various applications in freezer, cold store and air conditioning unit. • It is applicable to various applications in freezer, cold store and air conditioning unit.

Applicable Refrigerant Applicable Medium Temperature Applicable Ambient Temperature Of Solenoid Standard Voltage Of Solenoid Allowable Voltage Fluctuation For Solenoid Connection Of Solenoid Model EVR3-2 EVR3-3 EVR6-3 EVR6-4 EVR10-4 EVR10-5 EVR15-5 EVR15-6 EVR15-7 EVR20-7 EVR20-9 EVR25-9 EVR25-11 EVR32-11 EVR32-13 EVR40-13 EVR40-17

Connection Type Flare Welded 1/4 SAE 1/4 ODF 3/8 SAE 3/8 ODF 3/8 SAE 3/8 ODF 1/2 SAE 1/2 ODF 1/2 SAE 1/2 ODF 5/8 SAE 5/8 ODF 5/8 SAE 5/8 ODF 3/4 SAE 3/4 ODF -7/8 ODF -7/8 ODF -1-1/8ODF -1-1/8ODF -1-3/8ODF -1-3/8ODF -1-5/8ODF -1-5/8ODF -2-1/8ODF

Min. 0 0

R22

R134a R404A/R507

P ( bar) Max.MOPD Liquid

Max. Operating Pressure ( bar)

Kv(m3/h) 0.27 0.27 0.8 0.8 1.9 1.9 2.6 2.6 2.6 5 5

0.05 30

40

10.5 0.2

16 21

Nominal Refrigerating Capacity (kW) Vapour

Liquid

Model

HCFC or HFC ( Customer choice) -25ºC ~ + 105ºC -25ºC ~ +80ºC AC380V, AC220V/50Hz ( Custom design is available) +10% ~ -15% IP65 with terminal box

R407C

R22

R134a R404A/R507

R407C

Hot Gas R22

R134a

R404A/R507

R407C

EVR3

5.40

5.00

3.80

5.08

--

--

--

--

2.50

2.00

2.00

2.43

EVR6

16.10

14.80

11.20

15.13

1.80

1.30

1.60

1.60

7.40

5.90

6.00

7.18

EVR10

38.20

35.30

26.70

35.91

4.30

3.10

3.90

3.96

17.50

13.90

14.30

16.98

EVR15

52.30

48.30

36.50

49.16

5.90

4.20

5.30

5.43

24.00

19.00

19.60

23.28

EVR20

101.0

92.80

70.30

94.90

11.40

8.10

10.20

10.49

46.20

36.60

37.70

44.81

EVR22

121.0

112.0

84.30

113.7

13.70

9.70

12.20

12.60

55.40

43.90

45.20

53.74

EVR25

201.0

186.0

141.0

188.9

22.80

16.30

20.40

20.98

92.30

73.20

75.30

89.53

EVR32

322.0

297.0

225.0

302.5

36.50

26.10

32.60

33.58

148.0

117.0

120.0

143.56

EVR40

503.0

464.0

351.0

472.7

57.00

40.80

51.00

52.44

231.0

183.0

188.0

224.07

www.sanhehvac.com

16


SHF IMPROVED SOLENOID VALVE Features • • • • • •

Refrigerant:R12,R22;R134a,R404,R407C,R410,R502 Suitable Temperature: -30ºC ~ +105ºC Service Life: 100,000 cyeles Working Pressure: 3.0MPa Solenoid Coil: 12W SHF series solenoid valve is one upgraded version of SH series. • The valve is widely used in refrigeration compressor group, central air-conditioning, coldstorage equipment and bus air-conditioning system.

Model

Operating Principles

mm SHF2-02 SHF2-02S SHF3-03 SHF3-03S SHF7-03 SHF7-03S SHF7-04 SHF7-04S SHF8-03 SHF8-03S SHF10-04 SHF10-04S SHF13-05 SHF13-05S SHF16-06S SHF19-07S

Connection Size

Port Size

2.5 Direct Acting 3

7

8

Diaphragm Pilot Operated

10 13 16 19

SAE in. 1/4" -3/8" -3/8" -1/2" -3/8" -1/2" -5/8" ----

ODF mm --------10 -12 -16 ----

in. -1/4" -3/8" -3/8" -1/2" -3/8" -1/2" -5/8" 3/4" 7/8"

mm ---------10 -12 -16 19 22

Opening Pressure Differential (Bar) Max. Min. A.C. D.C. 21 19 21 19 0 21 19 21 19 21 19 21 19 21 19 21 19 21 17 21 17 0.05 21 17 21 17 21 17 21 17 21 17 21 17

Dimension (mm) Length 58 107 58 107 72 118 72 108 85 125 85 125 89 150 185 190

Width 24 24 24 24 30 30 30 30 45 45 45 45 45 45 60 60

Height 84 84 84 84 90 90 90 90 97 97 97 97 97 97 120 120

FDF SERIES SOLENOID VALVE Features • • • • • • • • •

Model FDF-2A FDF-3A FDF-4A FDF-6A FDF-8A

Movement Pattern

Diameter (mm)

Flow

Normally Close

Φ1.9 Φ3.0 Φ4.0 Φ6.0 Φ8.0

38 110 196 367 450

Note: Available with straight - thru or right angle design

17

Rated Voltage: AC220V, AC110V, DC24V Frequency: 50/60Hz Refrigerant: R22, R407C, R410A,etc. Maximum pressure:4.2Mpa Voltage:ranges from 85% to 110% of rated voltage Medium temperature:-30ºC ~ 120ºC Ambient temperature:-30ºC ~ 50ºC Relative humidity: 95% or less Movement Pattern: Normally Closed; Normally Open(Custom-made).

Internal Leakage Max. working Connection Size (mL/min) pressure (Mpa) (mm) ≤100 4.2 Φ6 ≤300 4.2 Φ8 ≤500 4.2 Φ6 ≤500 4.2 Φ8 ≤500 4.2 Φ8

Motion type Normal close Normal close Normal close Normal close Normal close


ST2/STE2 THERMAL EXPANSION VALVE Features • Application: regulating the flow rate of refrigerant into evaporators; • Type options: internal equalizer and external equalizer systems; • Orifice: Interchangeable; • Evaporator temperature: -40ºC ~ +10ºC.

Ordering Code Connection Type

Equalization

R12

R134A

R22

R404A R507

R407C

Internal

STF2

STN2

STX2

STS2

STZ2

External

STEF2

STEN2

STEX2

STES2

STEZ2

Internal

HTF2

HTN2

HTX2

HTS2

HTZ2

SAE Flare

ODF Solder

External

HTEF2

HTEN2

HTEX2

HTES2

HTEZ2

Specification Model

Equalization

ST2

Internal

STE2

External

HT2

Internal

HTE2

External

Connection Inlet x Outlet inch mm

Connection Type

Equalization connection

Capillary Length(m)

1/4 (6mm)

1

SAE Flare 3/8 x 1/2

10 x 12

ODF Solder

Nominal Refrigerating Capacity(-40ºC~ +10ºC) Orifice Size

R22

R407C

R134a

R404A/R507 KW

TR

KW

TR

KW

TR

KW

TR

0X

0.15

0.5

0.16

0.5

0.11

0.4

0.11

0.38

00

0.3

1

0.3

1.1

0.25

0.9

0.21

0.7

01

0.7

2.5

0.8

2.7

0.5

1.8

0.45

1.6

02

1.0

3.5

1.1

3.8

0.8

2.6

0.6

2.1

03

1.5

5.2

1.6

5.6

1.3

4.6

1.2

4.2

04

2.3

8

2.5

8.6

1.9

6.7

1.7

6.0

05

3.0

10.5

3.2

11.3

2.5

8.6

2.2

7.7

06

4.5

15.5

4.9

16.7

3.0

10.5

2.6

9.1

Remark: Nominal refrigerating capacity is based on the condensing temperature 32ºC, evaporating temperature 5ºC

www.sanhehvac.com

18


NRF(E)/RT(E) SERIES EXPANSION VALVE

Features • • • • •

Stable superheat setting Evaporating temperature range: -40ºC+10ºC MOP (Max. operating pressure) function is available Changeable inlet filter net Suitable for R22, R134a, R407c, R404A/R507

Superheat Adjusting Factory setting :superheat 3.5K,static superheat adjusting range is between 2~8K. Take off cap and turn adjusting stem. Turn adjusting stem anticlockwise one round,reduces superheat 1.5K.

R134a Model

R22 Nominal Capacity (KW)

Model

Nominal Capacity (KW)

NRF(E) RT(E)

1/4M

0.88

NRF(E) RT(E)

1/2H

1.76

NRF(E) RT(E)

1/2M

1.76

NRF(E) RT(E)

1H

3.52

NRF(E) RT(E)

1M

3.52

NRF(E) RT(E)

1-1/2H

5.28

NRF(E) RT(E)

1-1/2M

5.28

NRF(E) RT(E)

2H

7.04

NRF(E) RT(E)

2M

7.04

NRF(E) RT(E)

3H

10.56

NRF(E) RT(E)

2-1/2M

8.80

NRF(E) RT(E)

4H

14.08

NRF(E) RT(E)

3M

10.56

NRF(E) RT(E)

5H

17.60

NRF(E) RT(E)

4M

12.32

NRF(E) RT(E)

6H

21.12

NRF(E) RT(E)

5-1/2M

19.36

NRF(E) RT(E)

7-1/2H

26.40

NRF(E) RT(E)

7-1/2M

26.40

NRF(E) RT(E)

10H

35.20

NRF(E) RT(E)

9M

31.68

NRF(E) RT(E)

12H

42.24

Note :Nominal capacity is based on evaporating temperature te=4.4ºC, condensing temperature tc=40ºC, and refrigerant temperature ahead of valve t1= 38ºC

R407c Model

R404A/R507 Nominal Capacity (KW)

Model

Nominal Capacity (KW)

NRF(E) RT(E)

1/2N

1.76

NRF(E) RT(E)

1/3S

1.17

NRF(E) RT(E)

1N

3.52

NRF(E) RT(E)

2/3S

2.35

NRF(E) RT(E)

1-1/2N

5.28

NRF(E) RT(E)

1S

3.52

NRF(E) RT(E)

2N

7.04

NRF(E) RT(E)

1-1/2S

5.28

NRF(E) RT(E)

3N

10.56

NRF(E) RT(E)

2S

7.04

NRF(E) RT(E)

4N

14.08

NRF(E) RT(E)

3S

10.56

NRF(E) RT(E)

5N

17.6

NRF(E) RT(E)

3-1/2S

12.32

NRF(E) RT(E)

6N

21.12

NRF(E) RT(E)

4S

14.08

NRF(E) RT(E)

7-1/2N

26.4

NRF(E) RT(E)

5S

17.60

NRF(E) RT(E)

10N

35.2

NRF(E) RT(E)

7S

24.64

NRF(E) RT(E)

12N

42.24

NRF(E) RT(E)

8-1/2S

29.92

Note :Nominal capacity is based on evaporating temperature te=4.4ºC, condensing temperature tc=40ºC, and refrigerant temperature ahead of valve t1= 38º C

19


TCLE/TRFE SERIES EXPANSION VALVE

Naming Rule • Interchangeable orifice assembly ,easier stocking , easy capacity matching ,better service. • Stable superheat setting with bi-flow function. • MOP (Max. operating pressure) function is available. • Various connection type and size can be made according to customer’s requirement. • Suitable for R22, R134a, R407C, R404A/R507,R410A.

R134a

R22 Nominal capacity (KW)

Model

R407c Nominal capacity (KW)

Model

R404A/R507 Nominal capacity (KW)

Model

R410A

Nominal capacity (KW)

Model

Model

Nominal capacity (KW)

TCLE

1/4M

1.20

TCLE

1/2H

1.76

TCLE

1/2N

1.68

TCLE

1/3S

1.17

TCLE

2/3Z

2.20

TCLE

3/4M

2.29

TCLE

1H

3.52

TCLE

1N

3.49

TCLE

2/3S

2.35

TCLE

1-1/4Z

4.40

TCLE

1-1/2M

4.93

TCLE

2H

7.04

TCLE

2N

7.00

TCLE

1-1/2S

5.28

TCLE

2-1/2Z

8.80

TCLE

2-1/2M

10.91

TCLE

3H

10.55

TCLE

3N

10.23

TCLE

2S

7.04

TCLE

3-1/2Z

12.30

TCLE

3-1/2M

14.08

TCLE

5H

17.60

TCLE

5N

16.80

TCLE

3-1/2S

12.32

TCLE

6Z

21.10

TCLE

5-1/2M

19.36

TCLE

7-1/2H

26.40

TCLE

7-1/2N

25.75

TCLE

5S

17.60

TCLE

9Z

31.60

TCLE

7-1/2M

26.05

TCLE

10H

35.20

TCLE

10N

34.78

TCLE

7S

24.64

TCLE

12Z

42.20

TCLE

9M

30.72

TCLE

12H

42.24

TCLE

12N

41.85

TCLE

8-1/2S

29.92

TCLE

15Z

52.80

TRFE

11M

38.72

TRFE

14H

49.28

TRFE

14N

47.93

TRFE

10S

35.20

TRFE

17Z

60.00

TRFE

13M

45.76

TRFE

18H

63.36

TRFE

18N

61.59

TRFE

12S

42.24

TRFE

22Z

77.40

TRFE

16M

56.32

TRFE

22H

77.44

TRFE

22N

75.88

TRFE

15S

52.80

TRFE

26Z

91.50

TRFE

19M

66.36

TRFE

26H

91.52

TRFE

26N

90.79

TRFE

18S

63.36

TRFE

30Z

105.00

TRFE

25M

84.48

TRFE

35H

123.20

TRFE

35N

121.90

TRFE

25S

88.00

TRFE

42Z

147.80

TRFE

31M

105.6

TRFE

45H

158.40

TRFE

45N

156.78

TRFE

32S

112.64

TRFE

55Z

193.60

TRFE

45M

147.84

TRFE

55H

193.60

TRFE

55N

191.41

TRFE

38S

133.76

TRFE

65Z

228.80

TRFE

55M

193.60

TRFE

75H

264.00

TRFE

75N

262.50

TRFE

52S

183.04

TRFE

90Z

316.80

TRFE

68M

228.80

TRFE

100H

352.00

TRFE

100N

350.17

TRFE

70S

246.40

TRFE

100Z

352.00

TRFE

80M

280.60

TRFE

120H

420.70

TRFE

120N

416.70

TRFE

84S

295.70

TRFE

140Z

492.00

Note: Nominal capacity is based on evaporating temperature te=4.4ºC, condensing temperature tc=40ºC, and refrigerant temperature ahead of valve t1= 38ºC

www.sanhehvac.com

20


TB SERIES EXPANSION VALVE

Features • • • •

Model

Nominal capacity (kw) R134a R22

TB-1

0.50

0.70

TB-2

0.80

1.10

TB-3

1.00

1.40

TB-4

1.20

1.70

TB-5

1.60

2.80

TB-6

2.10

3.00

TB-7

3.10

4.40

TB-8

3.70

5.30

TB-11

4.90

7.00

TB-12

6.20

8.80

TB-13

7.20

10.20

TB-14

9.00

12.80

TB-15

9.50

14.00

TB-16

11.70

16.60

TB6-01

12.40

17.60

TB6-02

14.90

21.12

TB6-03

18.80

26.64

TB6-04

19.80

28.16

Type of equalization

Connection size

Capillary Length

Internal equalizated

ODF Inlet:1/4" Outlet:1/2"

1m 1.5m

Internal equalizated∆

ODF Inlet:1/2" Outlet:5/8"

1m 1.5m

Note: Condensing temperature +38ºC, evaporating temperature +5ºC; R134a: ∆P=0.46MPa, R22:∆P=0.69MPa.

21

Fixed static superheat temperature Suitable for small scale refrigeration system. ODF copper tube connections. Maximum working pressure: 2.8 MPa.


ELECTRONIC EXPANSION VALVE Features • S maller installation space: lower height, smaller volume, lower weight • High reliability • Low energy consumption • Suitable for reversible systems, such as heat pumps: bidirectional flow

Matching Fully PowOpen er(HP) Pulse "8.8( 2.5 )" 1.0 ~ 2.5 500 "7( 2.0 )" 1.0 ~ 1.75 500 "5.25( 1.5 )" 0.75 ~ 1.5 500 4.38( 1.25 ) 0.5 ~ 1.25 500 3.5( 1.0 ) 0.5 ~ 1 500

Model No.

DN R22 Capacity (mm) KW(USRT)

DPF(J) 2.0 DPF(J) 1.8 DPF(J) 1.6 DPF(J) 1.5 DPF(J) 1.3

Φ2.0 Φ1.8 Φ1.6 Φ1.5 Φ1.3

Open Valve Pulse 32±20 32±20 32±20 32±20 32±20

Max. Operating Pressure Pulse Difference(MPa) Frequency (PPS) R22 R407C R410a 30~90 2.26 2.48 3.43 30~90 2.26 2.48 3.43 30~90 2.26 2.48 3.43 30~90 2.26 2.48 3.43 30~90 2.26 2.48 3.43

CGX SERIES BYPASS VALVE

Connecting Pipe Size(mm) Φ6.35x0.7 Φ6.35x0.7 Φ6.35x0.7 Φ6.35x0.7 Φ6.35x0.7

Max. Working Pressure(Mpa) R22 R407C R410a 3 3.3 4.2 3 3.3 4.2 3 3.3 4.2 3 3.3 4.2 3 3.3 4.2

Features • Used in the refrigerating compressor set(without energy unloading device) to realize the systematic energy regulation. • Can be used as autometic expansion valve under fixed pressure to maintain the fixed evaporation pressure(temperature). • Can prevent the refrigerating compressor set from extract pressure decreasing lower than the minimum value. • Connecting means include flare with thread and ODF copper pipe welding. • Suitable mediums are various kinds of Freon and hydrocarbon compounds. • Maximum working pressure: 2.8 MPa. • To open or close within measure automatically when outlet pressure varies. • To ensure the outlet pressure constant on the set value in manual regardless the influence of the inlet pressure (within a certain range).

Model

Adjustment range

CGX-05 CGX-08 CGX-10 CGX-15 CGX-20 CGX-30

0 ~ 0.7 MPa

R134a 1. 5 2. 4 3.0 4. 2 5. 7 8. 5

Capability (KW) R22 2.8 4.5 5.6 8.4 11. 2 16. 8

R502 2.0 3.0 3.8 5.8 7.5 11. 7

Set pressure

ODF Connecting size

Weight (kg)

0 Mpa

Inlet : Φ8 x 1 Outlet : Φ10 x 1

0.15

www.sanhehvac.com

22


CBX SERIES BYPASS VALVE Features • The CBX hot gas-bypass valve is a kind of capacity adjust component for the refrigerating system with a non-adjustable compressor. • The CBX hot gas-bypass valve can be used as automatic expansion valve under fixed pressure to maintain the fixed evaporation pressure (temperature). • The CBX hot gas-bypass valve is capable of maintaining the minimum suction pressure. • ODF copper tube connections. • Suitable for HFC and HCFC. • Maximum working pressure: 28bar.

• CBX used as expansion valve under the fixed pressure. • CBX used as hot gas bypass valve to regulate capacity.

Model

Nominal capacity (kw) R407c R404A/507

R134a

R22

R410A

CBX-01

0.97

1.77

1.82

1.38

2.12

CBX-02

1.30

2.36

2.43

1.84

2.83

CBX-03

1.95

3.54

3.65

2.76

4.25

CBX-04

2.92

5.31

5.47

4.14

6.37

CBX-05

3.89

7.08

7.29

5.52

8.50

CBX-06

5.83

10.60

10.90

8.27

12.70

CBX-07

7.76

14.10

14.50

11.00

16.90

CBX-08

9.74

17.70

18.20

13.80

21.20

CBX-09

11.66

21.20

21.80

16.50

25.40

CBX6-01

13.60

24.70

25.40

19.30

29.60

CBX6-02

15.60

28.30

29.20

22.10

33.90

CBX6-03

17.50

31.80

32.80

24.80

38.20

CBX6-04

19.50

35.40

36.50

27.60

42.50

Note: Condensing temperature Te=3ºC, evaporating temperature Tc=38ºC; Refrigerant temperature ahead of valve: TL=37ºC; Subcooling: Tsub=1k;

23

Connection size

Inlet: φ8 ODF Outlet: φ12 ODM

Inlet:1/2" ODF Outlet:5/8" ODF


ELECTRONIC-DRAIN VALVE

Features

MIC-A

• Suitable for all applications, simple to install, fully automatic, maintenance-free. • Adjustable interval and discharge time and equipped with test button. • Pressure 16bar, various options for voltage and connection CE certification, patented products, protection class IP65, insulation class H level • Stainless steel valves, explosion-proof valve to choose from CE certification, patented products, protection class IP65, insulation class H level. • Equipped with ball valve filter, separated from the drain valve, with L-type structure. • Dimensions: 106 × 47 × 91mm, weight 570g

MIC-B

Timer

MICDRAIN

Time Interval (OFF)

0.5-45 Mins.

Discharge Time (ON)

0.5-10 Secs.

Manual Test Button

Micro Switch

Voltage

24-240V AC/DC 50/60Hz (Custom-made 380VAC)

Current Consumption

Max.: 4mA

Ambient Temperature

-40ºC ~ +60ºC

Protection Level

IP65

Shell Material

Flame-retardant ABS Plastic

Electrical Connection

DIN43650A

Indicator Light

LED(On/Off)

Valve

MIC-A

MIC-B

Type

2/2 directly operated valve

2/2 directly operated valve

Inlet / Outlet Dimensions

1/2" , 3/8" or 1/4"

1/2"

Maximum Working Pressure

16bar

16bar

Min. / Max. Ambient Temperature

2ºC/55ºC

2ºC/55ºC

Max. Medium Temperature

90ºC

90ºC

Valve Body

Forge Brass (Custom-made:Stainless Steel)

Forge Brass, Flow Aperture 1.0mm

Insulation Grade

Heat Resistance: Grade H

Heat Resistance: Grade H

Protection Level

IP65 (With Proper Installation)

IP65(With Proper Installation)

Voltage

24V ~ 230V AC/DC (Custom-made 380VAC)

24-230V AC/DC(Custom-made 380VAC)

Voltage Range

+/-10%

+/-10%

Installation Position

Random

Random www.sanhehvac.com

24


SEK MOLECULAR SIEVE LIQUID LINE FILTER DRIER • The automatic compressed device makes it possible to automatically fill in the wom molecules • High moisture and acid removal capacity • Motion of pads will not cause vibration • Drying and fiftering effect of combining • Filtration:20 microns • Two kinds of connection methods: ODF and SAE ;In order to facilitate welding. • ODF adoption of TP2 copper reserve • For a variety of refrigerant A-12. A-134a, A-22, R-404A, A-502 • Maximum working pressure: 4.5Mpa Connection Model SEK-032 SEK-032S SEK-033 SEK-033S SEK-052 SEK-052S SEK-053 SEK-053S SEK-082 SEK-082S SEK-083 SEK-083S SEK-084 SEK-084S SEK-162 SEK-162S SEK-163 SEK-163S SEK-164 SEK-164S SEK-165 SEK-165S SEK-167S SEK-303 SEK-303S SEK-304 SEK-304S SEK-305 SEK-305S SEK-306 SEK-306S SEK-307S SEK-309S SEK-413 SEK-414 SEK-414S SEK-415 SEK-415S SEK-416 SEK-416S SEK-417S SEK-419S

25

ODF

SAE

-1/4" -3/8" -1/4" -3/8" -1/4" -3/8" -1/2" -1/4" -3/8" -1/2" -5/8" 7/8" -3/8" -1/2" -5/8" -3/4" 7/8" 1-1/8" --1/2" -5/8" -3/4" 7/8" 1-1/8"

1/4" -3/8" -1/4" -3/8" -1/4" -3/8" -1/2" -1/4" -3/8" -1/2" -5/8" --3/8" -1/2" -5/8" -3/4" ---3/8" 1/2" -5/8" -3/4" ----

Liquid Flow Capacity (TONS) R22/ R407a/ R134a R407c/ R507 R410a 2

1.5

2

5

3.5

5.5

2

1.5

2

5

4

5.5

2

1.5

2

5.5

4

6

7.5

5.5

8

2

1.5

2

6

4.5

6.5

8.5

6

9

12

8.5

13.5

12

8.5

13.5

6

4.5

6.5

8.5

6

9.5

12.5

9

14

16.5

12

18.5

16.5 17.5 3.59 8.55 8.95 9.95 13 .98 15.35 15.21 16.66 22.75

12 12.5 4.39 10.41 10.85 12.00 17.02 14.03 19 20.35 22.78

18.5 19 4.15 11.32 11.74 13.05 1 8.41 15.04 20.3 22.01 30.25

R134a/ R507

Drying Capacity (lbs) R22/ desiccant R404a R407c/ (cu.in) R410a

15

24

14.5

3

19

28.5

17.5

5

27.5

44

27.5

8

59.5

96

59.5

19

126

204

126

30

263

427

263

65

L(mm) 131 121 139 125 128 118 136 112 152 142 160 146 162 152 164 154 172 158 174 164 186 166 174 239 225 241 231 253 233 235 235 241 245 239 225 241 231 253 241 245 232 235

B(mm)

D(mm)

85

54

82

63

106

63

118

63

185

76

185

89


SDK SOLID CORE LIQUID LINE FILTER DRIER Features

SDK series solid core liquid line tilter drier, using a high-quality compression of small spherical particles sintered desiccant module.combined with high-density filter doth, to dry and the role of filter .that can effectively tilter system residues of water and debris .

Model SDK-052 SDK-052S SDK-053 SDK-053S SDK-082 SDK-082S SDK-083 SDK-083S SDK-084 SDK-084S SDK-162 SDK-162S SDK-163 SDK-163S SDK-164 SDK-164S SDK-165 SDK-165S SDK-167S SDK-303 SDK-303S SDK-304 SDK-304S SDK-305 SDK-305S SDK-306S SDK-307S SDK-309S SDK-413 SDK-414 SDK-414S SDK-415 SDK-415S SDK-417S SDK-419S

Connection ODF

SAE

R134a

-1 /4 -3/8 -1 /4 -3/8 -1 /2 -1 /4 -3/8 -1 /2 -5/8 7/8 -3/8 -1 /2 -5/8 3/4 7/8 1-1/8 --1/2 -5/8 7/8 1-1/8

1/4 -3/8 -1/4 -3/8 -1/2 -1/4 -3/8 -1/2 -5/8 --3/8 -1/2 -5/8 ----3/8 1/2 -5/8 ----

1.72 2.72 2.91 3.62 1.89 2.56 3.33 3.76 5.56 5.88 1.96 2.56 3.19 3.61 5.88 7.1 8.02 8.32 1 2.78 3.61 5.23 6.64 8.78 8.78 10.32 12.12 13.84 16.12 3.58 8.56 8.96 9.96 13.98 16.66 22.75

• Small spherical particles of high strength sintered desiccant module ,to make runtime without shock and friction,reduce wear off the desiccant • High moisture and acid removal capacity • Drying and tittering effect of combining • Filtration:20 microns • With minimum pressure drop design allows the system to play better energy efficiency in the run-time • Two kinds of connection methods: ODF and SAE; In order to tacilitate welding, ODF adoption of TP2 copper reserve • Fora varitey of refrtgerant R-12.R-134a. R-22,R-404A,R-410A.R-S02 • Maximum working pressure: 4.5Mpa

Liquid Flow Capacity (TONS) R12/ R407a/ R12 R407c R410a R507 2.12 2.32 2.22 1.52 3.32 3.62 3.52 2.42 3.53 3.85 3.69 2.54 4.41 4.78 4.68 3.23 2.31 2.28 2.45 1.69 3.12 3.46 3.34 2.23 4.01 4.35 4.36 2.94 4.56 4.88 4.78 3.29 6.75 7.32 7.13 4.96 7.12 7.74 7.56 5.12 2.36 2.57 2.44 1.72 3.12 3.45 3.32 2.19 3.88 4.25 4.11 2.78 4.41 4.79 4.77 3.16 7.14 7.81 7.77 5.23 8.5 9.22 9.01 6.21 9.71 10.45 10.32 7.01 10.12 10.94 10.77 7.32 15 .56 1 6.87 16.54 11.26 4.34 4.71 4.61 3.61 6.36 6.87 6.78 4.63 8.13 8.89 8.64 5.92 10.62 11.52 11.36 7.74 10.69 11.56 11.35 7.74 12.51 13.52 13.33 9.12 14.84 16.06 15.75 10.71 16.84 1823 17.92 12.23 19.63 212 5 20.84 14.21 4.39 4.75 4.65 3.16 10.41 11.32 11.15 7.51 10.85 11.74 11.52 7.84 12.06 13.05 12.84 8.74 17.02 18.41 18.18 12.3 20.35 22.01 21.6 14.78 27.78 30.25 29.41 20.14

R502 1.52 2.31 2.54 3.13 1.58 2.23 2.84 3.19 4.76 5.07 1.63 2.19 2.71 3.13 5.12 6.02 6.82 7.12 10.92 3.11 4.45 5.71 7.53 7.54 8.84 10.44 11.84 13.84 3.09 7.31 7.61 8.54 12 14.35 19.51

L(mm) 123 113 132 116 142 132 150 136 152 142 161 151 170 156 171 161 183 163 172 234 220 236 226 248 228 230 236 240 250 252 242 264 244 252 256

B(mm) D(mm) -77 -77 -96 -96 ---115 -115 -115 -115 115 -180 -180 -180 180 180 180 196 -196 -196 196 196

63

63

76

76

89

www.sanhehvac.com

26


SDCL/SDML LIQUID LINE SOLID CORE DRIER

fig 1

fig 2

fig 3

fig 4

SDML/SDCL series liquid pipeline filter dryer absorbs water, acid and filters solid impurities to protect the refrigeration and air conditioning system. All drying filter core is a molecular sieve sintered filter, the core body of the SDML series is 100% molecular sieve and SDCL series 80% molecular sieve and 20% active aluminum.

Features • Solid filter is a molecular sieve particles stick together, don't move, avoid the powder produced • SDML series and SDCL series have copper over braze welding interface and threaded connections are available • SDML series have good drying and filtering ability, SDCL series with acid absorption and dry filtering capability

• Filtration precision of 25µm, can maintain effective filtering in the minimum pressure drop • Surface coated with corrosion resistant epoxy powder coating, match the requirement of 500 hours salt spray testing • Maximum working pressure of 45 bar • Applicable temperature -40ºC ~ +120ºC

Model Selection Medium type

Refrigerant

Oil

SDCL

SDML

HFC

Usable

Recommended

HCFC

Recommended

Usable

CFC

Recommended

Not applicable

Mineral oil or AB

Recommended

Usable

Pure POE or PAG

Usable

Recommended

Additive POE or PAG

Not applicable

Recommended

For CFC system, it is recommended to use l 038 series dry fillers, in these systems, may need lo use with acid absorption can filter dryer For oil additive in the system, is not recommended to contain active aluminum filter dryer

27


SDCL/SDML LIQUID LINE SOLID CORE DRIER

Specification Model SDML/SDCL-032 SDML/SDCL-032S SDML/SDCL-033 SDML/SDCL-033S SDML/SDCL-052 SDML/SDCL-052S SDML/SDCL-053 SDML/SDCL-053S SDML/SDCL-054 SDML/SDCL-054S SDML/SDCL-082 SDML/SDCL-082S SDML/SDCL-083 SDML/SDCL-083S SDML/SDCL-084 SDML/SDCL-084S SDML/SDCL-085 SDML/SDCL-085S SDML/SDCL-162 SDML/SDCL-l62S SDML/SDCL-l63 SDML/SDCL-l63S SDML/SDCL-l64 SDML/SDCL-l64S SDML/SDCL-165 SDML/SDCL-l65S SDML/SDCL-166 SDML/SDCL-l66S SDML/SDCL-l67S SDML/SDCL-303 SDML/SDCL-303S SDML/SDCL-304 SDML/SDCL-304S SDML/SDCL-305 SDML/SDCL-305S SDML/SDCL-306 SDML/SDCL-306S SDML/SDCL-307S SDML/SDCL-309S SDML/SDCL-413 SDML/SDCL-414 SDML/SDCL-414S SDML/SDCL-415 SDML/SDCL-415S SDML/SDCL-416 SDML/SDCL-416S SDML/SDCL-417S SDML/SDCL-419S

Connections ODF SAE -1/4 1/4 --3/8 3/8 --1/4 1/4 --3/8 3/8 --1/2 1/2 --1/4 1/4 --3/8 3/8 --1/2 1/2 --5/8 5/8 --1/4 1/4 --3/8 3/8 --1/2 1/2 --5/8 5/8 --3/4 3/4 -7/8 --3/8 3/8 --1/2 1/2 --5/8 5/8 --3/4 3/4 -7/8 -1-1/8 --3/8 -1/2 1/2 --5/8 5/8 --3/4 3/4 -7/8 -1-1/8 --

Pressure Drop ∆p = 0.07bar Fluid Refrigerating Capacity (Kw) R134a R404A R507R R22/R410A R407C 6.7 5.1 4.9 7.5 7.1 6.7 5.1 4.9 7.5 7.1 12.9 9.9 9.6 14.5 13.8 12.9 9.9 9.6 14.5 13.8 7.7 5.6 5.5 8.5 8.0 7.7 5.6 5.5 8.5 8.0 12.9 9.8 9.5 14.5 13.8 12.9 9.8 9.5 14.5 13.8 25.7 20.8 20.2 30.2 28.6 25.7 20.8 20.2 30.2 28.6 7.7 5.4 5.3 8.2 7.9 7.7 5.4 5.3 8.2 7.9 14.2 11.0 10.7 16.2 15.3 14.2 11.0 10.7 16.2 15.3 28.6 21.4 20.7 31.7 30.2 28.6 21.4 20.7 31.7 20.2 43.8 35.3 34.3 51.6 48.7 43.8 35.3 34.3 51.6 48.7 7.7 5.4 5.3 8.2 7.9 7.7 5.4 5.3 8.2 7.9 16.3 11.2 10.8 16.8 16.2 16.3 11.2 10.8 16.8 16.2 32.2 23.5 22.7 35.1 33.6 32.2 23.5 22.7 35.1 33.6 44.6 36.6 35.6 53.4 50.2 44.6 36.6 35.6 53.4 50.2 44.5 37.4 36.4 54.4 51.2 44.5 37.4 36.4 54.4 51.2 45.9 40.1 39.2 56.6 52.8 15.7 10.6 10.2 16.6 15.5 15.7 10.6 10.2 16.6 15.5 32.5 25.0 24.3 36.8 35.l 32.5 25.0 24.3 36.8 35.l 43.7 36.9 35.9 53.8 50.9 43.7 36.9 35.9 53.8 50.9 45.7 39.8 38.9 55.6 52.5 45.7 39.8 38.9 55.6 52.5 64.3 54.0 52.5 77.8 73.3 83.6 69.8 67.9 101.6 95.0 18.4 12.4 12.0 19.2 18.2 33.4 26.5 25.7 38.6 36.7 33.4 26.5 25.7 38.6 36.7 55.4 41.8 40.6 62.1 59.l 55.4 41.8 40.6 62.1 59.l 62.4 53.8 52.6 76.6 72.4 62.4 53.8 52.6 76.6 72.4 66.7 56.3 54.8 80.2 76.3 95.3 76.3 74.1 112.3 105.4

Dimensions (mm) A B D L 22.5 111 16.5 99 66 43 27.5 121 19.0 104 22.5 120 18.5 112 27.5 130 75 54 19.0 113 30.0 135 20.0 115 22.5 146 18.5 138 27.5 156 19.0 139 101 54 30.0 161 20.0 141 35.0 171 24.0 149 22.5 155 18.0 146 27.5 165 19.0 148 30.0 170 20.0 110 150 76 35.0 180 24.0 158 40.0 190 26.0 162 28.5 167 27.5 244 19.0 227 30.0 249 20.0 229 35.0 259 189 76 24.0 237 40.0 269 26.0 241 28.5 246 29.0 247 27.5 246 30.0 251 20.0 231 35.0 261 24.0 191 89 239 40.0 271 26.0 243 28.5 248 29.0 249

Type

fig 1

fig 2

fig 3

fig 3

fig 4

fig 4

Remark:1: The capacity to work status: liquid refrigerant temperature tc=30ºC, saturated evaporation temperaturete=-15ºC. the pressure drop ∆p=0.07bar: 2: It is not recommended used when pressure drop ∆P over than 0.14 bar.

www.sanhehvac.com

28


TWO-WAY FILTER DRIER

Features • Internal adopts automatic open and close the reversing device, refrigerant flow and fittration can be carried out in any one party • Installation position is not restricted • Surface coating with corrosion resistant epoxy powder coating, match the requirement of 500 hours salt spray testing • Maximum working pressure is 45bar To pretect the refrigerant in the refrigeration and heating circulation system, it effectively prevent buildup in a direction of pollutants in reversing flow back. Moreover, it saves two external check valve and a oneway filter in the design of unit, which reduces the pipe complexity and the corresponding cost.

Model SFK-082 SFK-082S SFK-083 SFK-083S SFK-084 SFK-084S SFK-085 SFK-085S SFK-162 SFK-162S SFK-163 SFK-163S SFK-164 SFK-164S SFK-165 SFK-165S SFK-166 SFK-166S SFK-167S SFK-303 SFK-303S SFK-304 SFK-304S SFK-305 SFK-305S SFK-306 SFK-306S SFK-307S SFK-309S

Connections ODF -1/4 -3/8 -1/2 -5/8 -1/4 -3/8 -1/2 -5/8 -3/4 7/8 -3/8 -l/2 -5/8 -3/4 7/8 1-1/8

SAE 1/4 -3/8 -1/2 -5/8 -1/4 -3/8 -1/2 -5/8 -3/4 --3/8 -1/2 -5/8 -3/4 ----

Pressure Drop ∆p = 0.07bar Fluid Refrigerating Capacity (Kw) R22 R410C R407C 7.0 7.0 6.9 7.8 7.8 7.4 15.8 15.8 15.4 17.8 17.8 17.4 22.5 22.5 22.1 23.6 23.6 23.2 27.4 27.4 26.6 28.5 28.5 27.8 8.1 8.8 8.4 10.9 12.0 11.6 16.2 16.2 15.8 18.3 18.3 17.9 27.1 27. l 26.7 28.5 28.5 27.8 29.2 29.2 28.5 30.6 30.6 29.9 34.5 34.5 33.6 36.6 36.6 35.9 40.2 40.2 39.6 18.3 18.3 17.9 20.4 20.4 20.0 26.8 26.8 26.4 34.1 34.l 33.4 36.3 36.3 35.5 50.0 50.0 48.9 43.0 43.0 40.2 56.3 56.3 55.3 58.8 58.8 57.7 68.9 68.9 67.8

Dimensions (mm) A 22.5 18.5 27.5 19 30 20 35 24 22.5 18.5 27.5 19 30 20 35 24 40 26 28.5 27.5 19 30 20 35 24 40 26 28.5 29

B 100 100 100 100 100 100 100 100 110 110 110 110 110 110 110 110 110 110 110 181 181 181 181 181 181 181 181 181 181

Remark:1: The capacity to work status: liquid refrigerant temperature tc=30ºC, saturated evaporation temperaturete=-15ºC. the pressure drop ∆p=0.07bar: 2: It is not recommended used when pressure drop ∆P over than 0.14 bar.

29

D 63.5 63.5 63.5 63.5 63.5 63.5 63.5 63.5 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76

L 145 137 155 138 160 140 170 148 155 147 165 148 170 150 180 158 190 162 167 236 219 241 221 251 229 261 233 238 239


SSF SUCTION LINE FILTER DRIER Features • The shortest length has to adapt to the compact installation • Low pressure drop, increase the effective filtration area with pleated filter design • Copper to take over the welded joint • Two repair valves, simplify the pressure drop measurement 5: Filtration precision 40µm • Surface coating with corrosion resistant epoxy powder coating, match the requirement of 500 hours salt spray testing • Maximum working pressure 35bar

SSF series suction line filter features large suction filter core, large shell diameter and internal refrigerant diffusion tube design, to reduce the installation length, provide big filter area and guarantee the maximum efficiency. The divergent tube inside distributes refrigerant evenly to avoid losses and protect the compressor effectively. Model SSF-283T SSF-284T SSF-285T SSF-286T SSF-287T SSF-289T SSF-2811T SSF-2813T

Connection (in) ODF 3/8" 1/2" 5/8" 3/4" 7/8" 1-1/8" 1-3/8" 1-5/8"

Filter Paperarea (in2) 83 83 83 141 141 141 219 219

OIL FILTER

Model SHOF-082 SHOF-082S SHOF-083 SHOF-083S SHOF-084 SHOF-084S SHOF-085 SHOF-085S

Connections ODF SAE -1/4 1/4 --3/8 3/8 --1/2 1/2 --5/8 5/8 --

Dimensions (mm) B D 112 89 112 89 112 89 152 89 152 89 152 89 205 89 205 89

A 19 20 24 26 28.5 29 32 32

L 150 152 160 204 209 210 269 269

Oil filters are of excellent capacity of filtration to insure the limited clean oil (pure POE oil, mineral oil and alkyl benzene oil) into compressor repeatedly. The pure oil could ensure the daily operation of oil level control. as well as reducing the damage of compressor. SHOF series oil filter could provide excellent performance of 3µm partides and sundries and get to 99%, which still have enough flow to remain low pressure drop. Moreover, it can prevent changing oil for compressor that caused by filtered feculence In practical application.

R134a 21.8 27.4 21.8 27.4 21.8 27.4 21.8 27.4

Liquid Flow Capacity (Kw) R22 R404A 23.7 15.7 29.8 19.8 23.7 15.7 29.8 19.8 23.7 15.7 29.8 19.8 23.7 15.7 29.8 19.8

R502 15.4 19.3 15.4 19.3 15.4 19.3 15.4 19.3

A 22.5 18.5 27.5 19 30 20 35 24

Dimensions (mm) B D 96 63.5 96 63.5 96 63.5 96 63.5 96 63.5 96 63.5 96 63.5 96 63.5 www.sanhehvac.com

L 141 133 151 134 156 136 166 144

30


DRY AND SUCTION FILTER CYLINDER

Application • It can match all brands of 48 series filter • Complete specifications, cylinder diameter 114mm, maximum interface size 3-1/8" • For measuring pressure drop and filling with 1/4 NPT access port • Liquid pipe application can choose 48 type drying filter core • The suction on the application can choose 48 type suction filter element

Model SH-485

31

ODF (in) 5/8

pressure drop ∆p(1 2)=0.07bar fluid refrigerating capacity (Kw) R12 R134a R22 R404A/507 R502 52.8 66.9 73.8 49.0 45.8

Size (mm) A 26

B 22

H 149

L 227

SH-487

7/8

97.6

123.2

132.8

88.6

84.8

27

25

150

228

SH-489

1-1/8

140.2

168.6

187.0

124.2

120.0

27

25

150

228

SH-4811

1-3/8

160.2

196.8

214.6

140.2

138.2

32

28

155

232

SH-4813

1-5/8

224.2

274.6

298.0

198.2

194.6

32

28

155

232

SH-4817

2-1/8

253.3

310.2

332.2

235.2

211.2

39

32

161

239

SH-4821G

2-5/8

274.6

335.4

348.6

260.5

232.3

54

50

152

245

SH-4824G

3

302.8

362.6

373.2

288.6

260.5

56

50

145

244

SH-4825G

3-1/8

345.2

386.3

394.4

302.2

278.0

56

50

144

243

SH-967

7/8

109.4

130.4

144.2

96.8

91.2

27

25

295

372

SH-969

1-1/8

165.4

205.6

221.8

148.6

138.6

27

25

295

372

SH-9611

1-3/8

207.6

252.4

278.0

183.0

178.4

32

28

300

377

SH-9613

1-5/8

225.3

276.4

299.2

197.6

192.5

32

28

300

377

SH-9617

2-1/8

257.0

330.8

337.6

288.5

267.4

39

32

306

384

SH-9621G

2-5/8

289.0

356.5

372.1

327.6

295.4

54

50

297

390

SH-9624G

3

323.2

380.4

383.2

360.5

320.4

56

50

290

389

SH-9625G

3-1/8

373.0

394.6

402.6

374.6

368.0

56

50

289

388

SH-1449

1-1/8

197.6

232.8

249.0

281.6

172.5

27

25

437

514

SH-14411

1-3/8

267.5

320.2

344.2

239.4

235.4

32

28

442

519

SH-14413

1-5/8

292.2

348.5

373.6

260.5

257.0

32

28

442

519

SH-14417

2-1/8

330.8

397.3

429.4

295.7

288.6

39

32

448

526

SH-14421G

2-5/8

369.6

394.2

408.3

380.2

345.0

54

50

439

532

SH-14424G

3

402.0

443.2

429.4

415.4

373.2

56

50

432

531

SH-14425G

3-1/8

436.3

454.1

464.5

447.5

380.2

56

50

431

530

SH-19211

1-3/8

285.4

336.8

366.0

253.2

248.6

32

28

592

669

SH-19213

1-5/8

306.2

369.2

397.6

274.5

267.4

32

28

592

669

SH-19217

2-1/8

341.4

408.8

438.2

308.6

296.4

39

32

298

676

SH-19221G

2-5/8

422.4

485.2

521.0

492.8

348.5

54

50

589

682

SH-19224G

3

456.2

507.8

534.6

510.4

406.4

56

50

582

681

SH-19225G

3-1/8

472.2

535.6

562.4

556.2

422.4

56

50

581

680

Filter element quantity

1

2

3

4


DRYING & SUCTION DRIER-FILTER CORE Features Filter cores and unloaded dryer shells produced by SANHE are most popular and replaceable. The filter cores packed with metal cans, having good leak tightness against dirty oil, substances and dust.

• Under special environment, capable of dissoving pollutants such as moisture and acid. • Protecting normal systems as well as clearing up compressors.

D/H Drier-Filter Cores Model

ΦD (mm)

H (mm)

A (mm)

D48

94

140

45

H48

94

140

45

H100

122

166

52

X Suction Line Filter Cores Model

ΦD (mm)

H (mm)

A (mm)

X48

94

140

64

X100

122

166

90

SX Suction Oil Filter Cores Model

ΦD (mm)

H (mm)

A (mm)

SX48

94

140

64

SX100

122

166

90

Mounting Brasket For Demountable Shells Model

ΦD (mm)

H (mm)

L (mm)

A (mm)

M114

114

169

98

10*20

M152

152

207

110

10*20

www.sanhehvac.com

32


SUCTION LINE ACCUMULATOR

In a refrigeration cycle, the refrigerant must be completely vaporized before returning to the compressor. Therefore, the gaseous and liquid refrigerant must be separated before the refrigerant enter the compressor, which will protect the compressor from the liquid hit/ slugging. And the liquid refrigerant will be stored in the accumulator. To make the liquid refrigerant return to the compressor, it will flow through the orifice at the bottom of U shape tube in the accumulator and return to the compressor together with the vapor. With the protection of accumulator, the compressor will have a longer working life and the system can run better.

Features • Prevents liquid slugging, controlled liquid return • Designed maximum flow and minimal pressure drop • Use with HFFC and HFC refrigerant and with associated oils • Stamped "Inter" position • Designed "U" shape for return tube • High corrosion-resistant paint coating finish • The max.working pressure 3.1 MPa,the burst pressure 19MPa, the Medium temperature: -40ºC ~ 120ºC

Technical parameters Conn. Size (inch)

ΦD

SH-384

1/2"

75

150

25

40

SH-595

5/8”

127

216

35

SH-596

3/4”

127

216

SH-5126

3/4”

127

SH-5127

7/8”

SH-5137

Model No.

33

H H1 A (mm) (mm) (mm)

Nominal Capacity(Kw) at the following evaporating temperature ºC R22

R134a

R404A

volume(L)

schematic drawing

-18ºC

5ºC

-18ºC

5ºC

-18ºC

5ºC

70

5.1

11.8

2.7

7.1

4.5

7.2

2.5

a

35

70

6.3

14.1

3.2

8.1

5.3

9.2

2.5

a

298

35

70

6.3

14.1

3.2

8.1

5.3

9.2

3.3

a

127

298

37

70

11.6

25.7

6.3

14.0

9.5

16.2

3.3

a

7/8”

127

323

37

70

11.6

25.7

6.3

14.0

9.5

16.2

3.6

a

SH-5139

1-1/8”

127

323

45

70

18.9

41.5

10.9

25.3

15.5

26.7

3.6

a

SH-5179

1-1/8”

127

426

45

70

18.9

41.5

10.9

25.3

15.5

26.7

5

a

SH-51711

1-3/8”

127

426

50

70

29.9

66.1

16.2

37.6

25.3

42.9

5

a

SH-61411

1-3/8”

159

348

50

70

29.9

66.1

16.2

37.6

25.3

42.9

6.5

a

SH-62013

1-5/8’’

159

515

55

70

45.0

101.3

25.7

59.8

37.6

64.0

9.5

a


SUCTION LINE ACCUMULATOR

In a refrigeration cycle, the refrigerant must be completely vaporized before returning to the compressor. Therefore, the gaseous and liquid refrigerant must be separated before the refrigerant enter the compressor, which will protect the compressor from the liquid hit/ slugging. And the liquid refrigerant will be stored in the accumulator. To make the liquid refrigerant return to the compressor, it will flow through the orifice at the bottom of U shape tube in the accumulator and return to the compressor together with the vapor. With the protection of accumulator, the compressor will have a longer working life and the system can run better.

Features • Prevents liquid slugging, controlled liquid return • Designed maximum flow and minimal pressure drop • Use with HFFC and HFC refrigerant and with associated oils • Stamped "Inter" position • Designed "U" shape for return tube • High corrosion-resistant paint coating finish • The max.working pressure 3.1 MPa,the burst pressure 19MPa,the Medium temperature -40ºC ~ 120ºC

Technical parameters Nominal Capacity(Kw) at the following evaporating temperature ºC H H1 A volume(L) R22 R134a R404A (mm) (mm) (mm) -18ºC 5ºC -18ºC 5ºC -18ºC 5ºC

Model No.

Conn. Size (inch)

ΦD

SH-204

1/2”

102

224

30

53

3.2

7.0

2.17

4.3

2.8

4.6

1.6

a

SH-205

5/8”

102

264

30

53

4.9

10.5

2.8

6.0

4.2

7.0

1.9

a

SH-206

3/4”

140

276

36

80

6.3

14.1

3.2

8.1

5.3

9.2

3.8

a

SH-207

7/8”

140

326

36

80

11.6

25.7

6.3

14.0

9.5

16.2

4.4

a

SH-208

1-1/8”

165

413

40

82

18.9

41.5

10.9

25.3

15.5

26.7

8

a

SH-209

1-3/8”

165

533

40

82

29.9

66.1

16.2

37.6

25.3

42.9

10.5

a

SH-210

1-5/8’’

165

583

40

82

45.0

101.3

25.7

59.8

37.6

64.0

11.5

a

SH-221

2-1/8”

219

750

50

120

-

-

-

-

-

-

24

b

SH-1817

2-1/8”

219

490

50

120

-

-

-

-

-

-

18

b

schematic drawing

www.sanhehvac.com

34


HEAT EXCHANGER ACCUMULATOR SH heat exchanger suction acumulator has strong construction. It can prevent the lose of refrigerating capacity well.In the cooling system,it is separated high pressure and low pressure about the refrigerant flowing pipeline. The refrigerant which is higher temperature in the high pressure pipeline would be cooled via the condenser, but the regrigerant which is lower temperature via the evaporator would be separated gas and liquid in the suction line accumulator. the liquid refrigerant would be evaporated into full gaseity by the heat and enter into the compressor. it prevent slugging the compressor by liguid refrigerant, so that the lifetime of the compressor is longer.

Features • The firm steel shells for long Iife • High resistant corrosion pant power coating finish • Max.working pressure:2.8MPa,the burst pressure 17.5MPa • It is suitable with HFC, HCFC, CFC refrigerant and with associated oil • It is strongly commended to instalI the heat exchanger accumulator when the evapour temperature is lower than -15ºC in the refrigeration system

Technical Parameters Model No.

35

Suction line Liquid State tube(inch) tube(inch)

ΦD(mm)

H(mm)

H1(mm)

A(mm)

B(mm)

Volume(L)

Schematic Drawing

SH-2404

1/2"

3/8"

102

224

30

53

53

1.6

a

SH-2405

5/8"

3/8"

102

264

30

53

53

1.9

a

SH-2406

3/4"

1/2"

140

276

36

80

80

3.8

a

SH-2407

7/8"

1/2"

140

326

36

80

80

4.4

a

SH-2411

1-1/8''

5/8"

165

413

40

82

82

8

a

SH-2413

1-3/8"

3/4"

165

533

40

82

82

10.5

a

SH-2415

1-5/8''

7/8"

165

583

40

82

82

11.5

a

SH-2421

2-1/8"

7/8"

219

490

50

120

120

18

b


CONVENTIONAL OIL SEPARATOR

It is intended for low pressure oil control system and compatible to HFC and HCFC refrigerants(R134a,R404A, R507,R407A,R407C,R22etc ). It's designed for use with scroll and reciprocating type com­pressor, but not recommended for crew or rotary vane compressors.

Features • • • • • •

Medium Temperature: -40 ~ +120° C Max.working pressure: 3.1MPa Burst pressure: 19MPa Oil storage volume: 55813→559011-- 600ml, 569011→569417-- 1000ml The thickness of paint film thickness: 50→80um

Technical Parameters Nominal capacity(Kw) at the following evaporating temperature ºC R22 R143a R404A/R507 -40ºC -20ºC 5ºC -40ºC -20ºC 5ºC -40ºC -20ºC 5ºC

Connection Size (inch)

ΦD

SH-55813

3/8"

102

242

35

48

4.8

5.9

6.4

2.9

4.0

5.6

4.8

5.7

6.3

SH-55824

1/2"

102

242

35

48

5.3

6.2

7.0

3.2

4.5

6.2

5.3

6.2

7.0

SH-55855

5/8"

102

336

37

48

15.8

17.5

19.3

11.4

13.4

15.8

14.4

16.4

19.3

SH-55866

3/4"

102

336

37

48

24.6

26.2

28.1

16.7

19.3

22.4

22.8

25.2

28.8

SH-55877

7/8"

102

418

39

48

24.6

26.2

28.1

16.7

19.3

22.4

22.8

25.2

28.8

SH-55888

1"

102

448

45

48

31.7

34.3

37.0

22.4

26.3

29.9

30.0

33.4

37.4

SH-55889

1-1/8"

102

448

45

48

31.7

34.3

37.0

22.4

26.3

29.9

30.0

33.4

37.4

SH-559011

1-3/8"

102

473

45

48

40.4

43.6

47.5

28.1

33.6

40.4

36.7

43.3

49.0

SH-569011

1-3/8"

159

350

43

70

45.2

47.4

49.2

33.4

40.4

48.4

41.0

45.2

50.8

SH-569213

1-5/8"

159

428

48

70

56.3

58.9

63.3

41.3

48.4

56.3

51.0

57.3

65.1

SH-569417

2-1/8"

159

490

52

70

91.4

102.3

105.5

63.3

74.8

88.8

88.5

98.4

108.6

Model

Dimensions(mm) H(mm) H1(mm) A(mm)

www.sanhehvac.com

36


DEMOUNTABLE (FLANGE) OIL SEPARATOR

It is intended for low pressure oil control system and compatible to HFC and HCFC refrigerants(R134a,R404A, R507,R407A,R407C,R22etc ). It's designed for use with scroll and reciprocating type com­pressor, but not recommended for crew or rotary vane compressors.

Features • Medium Temperature: -40 ~ +120° C • Max.working pressure: 3.1MPa • Burst pressure: 19MPa • Oil storage volume: 5300→5305 600ml, 6303→6305 1000ml • The thickness of paint film thickness: 50→80um

Technical Parameters

37

Nominal capacity(Kw) at the following evaporating temperature ºC R22 R143a R404A/R507 H(mm) H1(mm) A(mm) -40ºC -20ºC 5ºC -40ºC -20ºC 5ºC -40ºC -20ºC 5ºC

Connection Size (inch)

ΦD

SH-5300

3/8"

102

247

30

48

4.8

5.9

6.4

2.9

4.0

5.6

4.8

5.7

6.3

SH-5301

1/2"

102

247

30

48

5.3

6.2

7.0

3.2

4.5

6.2

5.3

6.2

7.0

SH-5302

5/8"

102

341

32

48

15.8

17.5

19.3

11.4

13.4

15.8

14.4

16.4

19.3

SH-5302A

3/4"

102

341

32

48

24.6

26.2

28.1

16.7

19.3

22.4

22.8

25.2

28.8

SH-5303

7/8"

102

423

34

48

24.6

26.2

28.1

16.7

19.3

22.4

22.8

25.2

28.8

SH-5303A

1"

102

453

40

48

31.7

34.3

37.0

22.4

26.3

29.9

30.0

33.4

37.4

SH-5304

1-1/8"

102

453

40

48

31.7

34.3

37.0

22.4

26.3

29.9

30.0

33.4

37.4

SH-5305

1-3/8"

102

478

40

48

40.4

43.6

47.5

28.1

33.6

40.4

36.7

43.3

49.0

SH-6303

1-3/8"

152

355

38

70

45.2

47.4

49.2

33.4

40.4

48.4

41.0

45.2

50.8

SH-6304

1-5/8"

152

433

43

70

56.3

58.9

63.3

41.3

48.4

56.3

51.0

57.3

65.1

SH-6305

2-1/8"

152

495

47

70

91.4

102.3

105.5

63.3

74.8

88.8

88.5

98.4

108.6

Model

Dimensions(mm)


MECHANICAL OIL LEVEL REGULATOR

Mechanical oil level regulator is to control oiI level in the compressor crankcase to protect the compressor. Mechanical oil level regulators are used in low pressure oiI management system.They are designed for use with reciprocating compressors, but not recommended for scroll compressors.

Features • Proven needle valve design • Stainless steeI float ball • Special mounting flange allows direct fitting to standard compressors • VisuaI indication of oil level via large sight glass • Allowable working pressure: 0 MPa ~ 3.1MPa • Allowable working temperature: 0ºC~ 100ºC

How it works Oil fed to oil level regulator by inlet connection, an internal needle valve either allows or shuts off an oil supply to the regulator. An internal ball float controls the position of the needle valve. During the compressor operation, the crankcase oil level reduces and a reduction in oil level activates the regulator, which ensures the correct crankcase oil Ievel is achieved and maintained. Adjuslable mechanical oil level regulator has in- built mechanism that allows the ball float to be adjustable: up or down. Some regulator models are fitted with an equalization connection which enable the oil levels between several compressors to be balanced.

Technical parameters Model SHOLC-A1 SHOLC-A2

ΦD (mm) 102 102

H (mm) 115 115

H1 (mm) 60 60

A (mm) 101 101

Sight Glass QTY 1 2

Model SHOLC

ΦD (mm) 102

H (mm) 115

H1 (mm) 55

A (mm) 100

B (mm) 100 www.sanhehvac.com

38


VERTICAL LIQUID RECEIVER

Liquid receivers are used in refrigeration systems for the purpose of allowing the system to adjust to varying loads. They should be able to store liquid refrigerant for evaporators, which ensures only liquid refrigerant enters the liquid line and stores all of the liquid refrigerants in the system when the system maintain.

Features • With the PTFE sealing gasket. • High corrosion-resistant powder coating finish, it can be use in aII environments, including marine applications • Refrigerant: HFC, HCFC, CFC, as well as with their associated oil. • Max. allowance working pressure: 4.2MPa, burst pressure: 19MPa • Allowance working temperature: -40°C ~ 100°C: • Can design and customize special receivers as customer's requirement.

Specification

39

Model

ODF Conn.(in)

ΦD (mm)

H (mm)

H1 (mm)

H2 (mm)

A (mm)

volume (L)

SH-01

3/8"

89

194

132

40

40

1.1

SH-02

3/8"

127

258

181

40

40

2.8

SH-03

3/8"

127

289

204

40

40

3.9

SH-04

1/2"

159

348

277

40

40

6.3

SH-05

5/8"

165

414

320

45

45

8

SH-06

3/8"

165

560

510

45

45

12

SH-07

7/8"

165

700

610

45

45

14


VERTICAL LIQUID RECEIVER

Liquid receivers are used in refrigeration systems for the purpose of allowing the system to adjust to varying loads. They should be able to store liquid refrigerant for evaporators, which ensures only liquid refrigerant enters the liquid line and stores all of the liquid refrigerants in the system when the system maintain.

Features • With the PTFE sealing gasket. • High corrosion-resistant powder coating finish, it can be use in aII environments, including marine applications • Refrigerant: HFC, HCFC, CFC, as well as with their associated oil. • Max. allowance working pressure: 4.2MPa, burst pressure: 19MPa • Allowance working temperature: -40°C ~ 100°C: • Can design and customize special receivers as customer's requirement.

Specification Model

ODF Conn.(in)

ΦD(mm)

H(mm)

H1(mm)

A(mm)

volume(L)

schematic drawing

SH-133

3 /8"

102

180

40

45

1

a

SH-233

3/8"

127

195

40

50

2

a

SH-333

3/8"

127

310

40

50

3

a

SH-433

3/8"

165

245

40

55

4

a

SH-644

1/2"

165

330

40

55

6

a

SH-844

1/2"

165

415

40

55

8

a

SH-1055

5/8"

219

310

45

75

10

b

SH-1255

5/8"

219

370

45

75

12

b

SH-1455

5/8"

219

430

45

75

14

b

SH-1677

7/8"

219

489

50

75

16

b

SH-1877

7/8"

219

549

50

75

18

b

SH-2177

7/8"

219

610

50

75

21

b

www.sanhehvac.com

40


VERTICAL LIQUID RECEIVER 1. SANHE according to the specific needs of customers design and manufacture of special liquid receiver 2. Design for during normal operation and system maintenance storage refrigerants 3. Allows the system to adjust to adapt to the different conditions and load system 4. Structure design for vertical and horizontal optional 5. Available for selection: depending on the liquid mirror, cut-off valve, mounting bracket, the welding joint, threaded connection, the relief valve connection mouth mouth, fusible plug, etc 6. Surface coated with corrosion resistant epoxy powder coating

Features • Adopt the manufacture drawing structure design • The fluid end equipped with cut-off valve, fluid end can match threaded connectors or welding • Vertical accumulator in order to achieve the best operation, should be installed vertically • Maximum working pressure 35 bar

Specification

41

Overall dimensions(mm)

Model

Inlet A (in)

Outlet B (in)

D

h

H

d

SH-03-1L

3/8

3/8

91

40

230

63.5

1.0L

SH-03-2.1L

3/8

3/8

120

40

260

76

2.1L

SH-04-3.2L

1/2

1/2

150

40

260

76

3.2L

SH-43-3.2L

1/2

3/8

150

40

260

76

3.2L

SH-04-4L

1/2

1/2

150

40

320

76

4.0L

SH-43-4L

1/2

3/8

150

40

320

76

4.0L

SH-04-5.5L

1/2

1/2

180

40

290

76

5.5L

SH-04-6.2L

1/2

1/2

180

40

318

76

6.2L

SH-04-7L

1/2

1/2

180

40

350

76

7.0L

SH-54-7L

5/8

1/2

180

40

350

76

7.0L

SH-05-7L

5/8

5/8

180

40

350

76

7.0L

SH-05-10L

5/8

5/8

220

40

350

89

10.0L

SH-05-12L

5/8

5/8

220

40

400

89

12.0L

SH-65-12L

3/4

5/8

220

40

400

89

12.0L

SH-65-14L

3/4

5/8

220

40

450

89

14.0L

SH-07-14L

7/8

7/8

220

45

455

89

14.0L

SH-09-14L

1-1/8

1-1/8

220

53

463

89

14.0L

Cubage


VERTICAL LIQUID RECEIVER 1. SANHE according to the specific needs of customers design and manufacture of special liquid receiver 2. Design for during normal operation and system maintenance storage refrigerants 3. Allows the system to adjust to adapt to the different conditions and load system 4. Structure design for vertical and horizontal optional 5. Available for selection: depending on the liquid mirror, cut-off valve, mounting bracket, the welding joint, threaded connection, the relief valve connection mouth mouth, fusible plug, etc 6. Surface coated with corrosion resistant epoxy powder coating

Features • Adopt the manufacture drawing structure design • The fluid end equipped with cut-off valve, fluid end can match threaded connectors or welding • Vertical accumulator in order to achieve the best operation, should be installed vertically • Maximum working pressure 35 bar

Specification Inlet A

Outlet B

(in)

(in)

D

E

F

H

Φd

SH-101

3/8"

1/4"

91

145

145

230

63 . 5

1.2 L

SH-102

3/8"

3/8"

127

170

170

255

76

2.8 L

SH-103

3/8"

3/8"

127

228

228

317

76

3.5 L

SH-104

1/2"

1/2"

156

285

285

372

76

6.3 L

SH-105

5/8"

5/8"

180

332

285

422

89

9.6 L

Model

Dimensions (mm)

Cubage

www.sanhehvac.com

42


HORIZONTAL LIQUID RECEIVER Features • Adopt the steel structure design • In/out liquid interface can be customized according to customer's requirements • There is no limit on the cut-off valve installation Angle, depending on the liquid lens is optional • Horizontal accumulator in order to achieve the best operation, should be installed • Surface coated with corrosion resistant epoxy powder coating • Maximum working pressure 35 bar

Model SH-07B-20.8L SH-07B-30.2L SH-07B-39.3L

Inlet A (in) 1-1/4-12UUNF 1-1/4-12UUNF 1-1/4-12UUNF

Outlet B (in) 7/8 7/8 7/8

ΦD 219 219 219

E 159 116 116

F 390 713 983

Dimensions (mm) M N I 132 400 111 172 600 214 237 740 349

J 381 381 381

H 549 829 1099

L 664 944 1214

Cubage 20.8 L 30.2 L 39.3 L

Features • Adopt the steel structure design • In/out liquid interface can be customized according to customer's requirements • There is no limit on the cut-off valve installation Angle, depending on the liquid lens is optional • Horizontal accumulator in order to achieve the best operation, should be installed • Surface coated with corrosion resistant epoxy powder coating • Maximum working pressure 35 bar

Technical parameters Model SH-07-12L SH-05-14.3L SH-07-14.3L SH-07A-18L SH-05A-23.1L SH-07A-26.7L SH-07A-30L SH-07A-33.4L SH-09A-33.4L SH-07A-40L SH-09A-40L SH-07A-45L SH-09A-45L SH-11A-45L SH-09A-50.4L SH-11A-50.4L SH-09A-54.7L SH-11A-54.7L

43

Inlet A (in) 7/8" 5/8" 7/8" 7/8" 5/8" 7/8" 7/8" 7/8" 1-1/8" 7/8" 1-1/8" 7/8" 1-1/8" 1-3/8" 1-1/8" 1-3/8" 1-1/8" 1-3/8"

Outlet B (in) 7/8" 5/8" 7/8" 7/8" 5/8" 7/8" 7/8" 7/8" 1-1/8" 7/8" 1-1/8" 7/8" 1-1/8" 1-3/8" 1-1/8" 1-3/8" 1-1/8" 1-3/8"

ΦD 159 159 159 159 219 219 219 219 219 273 273 273 273 273 273 273 273 273

E 110 110 110 120 140 150 150 150 150 160 160 160 160 160 160 160 160 160

F 450 580 580 760 420 500 600 700 700 480 480 580 580 580 680 680 780 780

Dimensions (mm) M N I 110 450 120 140 520 120 140 520 220 175 760 220 120 460 220 135 530 220 175 550 220 175 650 220 175 650 220 150 500 220 150 500 220 150 600 220 150 600 220 150 600 220 175 650 220 175 650 220 200 700 220 200 700 220

J 165 165 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270

H 110 110 110 110 139.5 139.5 139.5 139.5 139.5 166.5 166.5 166.5 166.5 166.5 166.5 166.5 166.5 166.5

L 670 800 800 1000 700 800 900 1000 1000 800 800 900 900 900 1000 1000 1100 1100

Cubage 12.0 L 14.3 L 14.3 L 18.0 L 23.1 L 26.7 L 30.0 L 33.4 L 33.4 L 40.0 L 40.0 L 45.0 L 45.0 L 45.0 L 50.4 L 50.4 L 54.7 L 54.7 L


OIL RECEIVER The oil receiver is the container of spare oil which has sight glass ports to observe the oil level in the device. The valve on the top of it gets oil from oil separator. The valve on the bottom of it can distribute the oil to oil regulator.There is a 1/4 inch threaded connection on the side of valve to increase or decrease spare oil.High pressure gas returns with the oil from the oil separator to it. The pressure would cause negative effects to oil controller.To prevent this phenomenon,a vent line is installed from the top of the oil receiver to suction line. This line permits the pressure in the oil receiver to be approximately same as suction line and compressor crankcase

Features • • • •

Multiple models for choices Sight glass with floating ball Seal ring is made of PTFE gasket Standard models suppliped with U type mounting brackets to install conveniently • The surface is corrosion resistant epoxy powder coating • Maximum working pressure: 35 Bar

Connection Size Model

Dimensions (mm)

Cubage (L)

(In/Out) ODF

SAE

ΦD

A

B

h

H

Cubage I

Cubage II

Gross Capacity

SHOC-633

3/8"

1/4NPT

159

97

150

344

426

1.6 L

4.4 L

6.0 L

SHOC-833

3/8"

1/4NPT

159

110

220

440

522

1.9 L

5.9 L

7.8 L

SHOC-1033

3/8"

1/4NPT

159

132

285

549

631

2.3 L

7.5 L

9.8 L

SHOC-1233

3/8"

1/4NPT

159

140

360

640

722

2.4 L

9.1 L

11.5L

SHOC-1433

1/2"

1/4NPT

159

194

350

739

821

3.4 L

9.8 L

13.2 L

SHOC-1955

1/2"

1/4NPT

219

140

300

580

662

4.3 L

14.7 L

19.0 L

SHOC-2355

5/8"

1/4NPT

219

140

420

700

782

4.2 L

18.9 L

23.1 L

www.sanhehvac.com

44


SHELL & TUBE HEAT EXCHANGER

Features • High efficiency, coefficient up to 10000W/m2C. Heat exchanging capacity 3-7 times traditional equipments. • Compact configure, occupy small area, one tenth as the traditional equipments • Stainless steel and/or titanium material, endure high temperature, pressure and corruption. • Helix screw thread elasticity heat exchange bundle, eliminate the stress. • Design flux speed is 5.5m/s, less dirt. • ASME standard VIII-1. • Big flow volume. • Easy installation and durable.

Model

A (mm)

B (mm)

C

E

SH-55K SH-85K SH-155K SH-210K SH-300K SH-360K SH-600K SH-1200K SH-2400K SH-3000K SH-3600K SH-4500K SH-5000K SH-6000K

60 60 76 76 76 89 114 133 168 168 168 219 219 219

360 520 450 570 780 830 900 900 950 1100 1300 1070 1120 1220

3/4" 3/4" 1" 1-1/2" 1-1/2" 1-1/2" 2" 2" 2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2"

1" 1" 1-1/2" 1-1/2" 2" 2" 2-1/2" 2-1/2" 4" 4" 4" 4" 4" 4"

Model SH-55K SH-85K SH-155K SH-210K SH-300K SH-360K SH-600K SH-1200K SH-2400K SH-3000K SH-3600K SH-4500K SH-5000K SH-6000K

45

kW 16 25 45 61 88 105 175 352 704 880 1056 1320 1467 1760

Normal Capacity Kbtu/hr 55 85 155 210 300 360 600 1200 2400 3000 3600 4500 5000 6000

Pool Capacity Gallons @ 1° F/hr Liters @ 1°C/hr 4700 32021 7300 49735 13300 90613 18000 122634 25800 175776 31500 214610 52500 357684 105600 719455 211200 1438910 264000 1798638 316800 2158365 396000 2697956 439000 3000000 526800 3600000

Heat Transfer Area m2 0.15 0.25 0.33 0.44 0.64 0.85 1.55 2.01 4.47 5.30 6.42 8.46 8.87 10.64


NOTE

www.sanhehvac.com

46


NINGBO SANHE REFRIGERATION CO., LTD 1105, 535th, Tiantong South Road, Yinzhou District, Ningbo, Zhejiang, China 315100

Telephone: 0086-574-82833733

Fax: 0086-574-88226612

Email: sales@sanhehvac.com

www.sanheHVAC.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.