R
--- REFRIGERATION PARTS
SANHE REFRIGERATION
ABOUT US Our Company
About Us NINGBO SANHE REFRIGERATION CO., LTD. was established in 1998 to supply spare parts for HVAC/R industry. Over the past years, NINGBO SANHE has earned its reputation as the leading supplier among customers due to its experience, professionalism and integrity. Dedicated NINGBO SANHE team attends to each customer’s specific requirements and helps customers make informed buying decisions.
Our Mission NINGBO SANHE will use wide knowledge in products and services, to supply the most suitable refrigeration parts and system solution to our customer.
Our Vision NINGBO SANHE is committed to providing the best services and meeting the needs of businesses through reliable quality, competitive price, and repid delivery. Our hope is to be the most professional One-Stop HVAC/R parts and system solution supplier.
A
Our Factory
Certification
www.sanhehvac.com
B
CONTENTS
01
SINGLE PRESSURE CONTROL
01
02
Single Pressure Control
DOUBLE PRESSURE CONTROL
EXPANSION VALVE
18
ST2/STE2 Thermal Expansion Valve
19
NRF(E)/RT(E) Series Expansion Valve
20
TCLE/TRFE Series Expansion Valve
21
TB Series Expansion Valve
02
Double Pressure Control
03
Delay Time Differential Pressure Control
03
Differential Pressure Control
22
04
SH55/58 Pressure Control
22
Electronic Expansion Valve
22
CGX Series Bypass Valve
23
CBX Series Bypass Valve
05
THERMOPLASTIC CAPILLARY
HOSE
BYPASS VALVE
24 25
ELECTRONIC-DRAIN VALVE
06
SIGHT GLASS
FILTER DRIER
SGS Series
25
SEK Molecular Sieve Liquid Line Filter Drier
06
SGN Series
26
SDK Solid Core Liquid Line Filter Drier
06
SG Series
27
SDCL/SDML Liquid Line Solid Core Drier
29
Two-Way Filter Drier
30
Oil Filter
30
SSF Suction Line Filter Drier
06
07
VALVE
07
BV Series Ball Valve
08
Standard Ball Valve
31
09
Hand Valve
CYLINDER
10
Magnetic Check Valve
31
Dry And Suction Filter Cylinder
11
Plunger Check Valve
32
Drying & Suction Drier-Filter Core
11
Globe Valve
32
D/H Drier-Filter Cores
12
Rotalock Valve
32
X Suction Line Filter Cores
Split Valve
32
SX Suction Oil Filter Cores
32
Mounting Brasket For Demountable Shells
13
14
VIBRATION ABSORBER TUBE
14
15
Vibration Absorber Tube
SOLENOID VALVE
C
18
33
DRY AND SUCTION FILTER
SUCTION LINE ACCUMULATOR
33
Suction Line Accumulator
35
Heat Exchanger Accumulator
15
SH Series Solenoid Valve
16
EVR Solenoid Valve
36
17
SHF Improved Solenoid Valve
36
Conventional Oil Separator
17
FDF Series Solenoid Valve
37
Demountable (Flange) Oil Separator
38
Mechanical Oil Level Regulator
OIL SEPARATOR
39
LIQUID RECEIVER
39
Vertical Liquid Receiver
43
Horizontal Liquid Receiver
44
OIL RECEIVER
44
45
Oil Receiver
SHELL & TUBE HEAT EXCHANGER
45
46
Shell & Tube Heat Exchanger
NOTE
www.sanhehvac.com
D
SINGLE PRESSURE CONTROL
• Scale plate use “bar” & “psig” units • Could be use “MPa” , “ kgf/cm2” units also as customer requirement. • Connection could as customer requirement use British unit flare(E), solder(S) and capillary(C)such as SHP506E; • Ammonia refrigerant model added a code B, such as SHP506B.
Rated voltage(V) Rated Amps(A) Non-Inductive Current Full Load Current Inductive Current Locked Roter
01
125V AC
250V AC
24V DC
20A 15A 72A
10A 8A 72A
10A 8A 64A
Differential Pressure (bar)
Factorly Setting (bar) Fig.1 Fig.2 1 0.5
Max.Bellows Press (bar)
Model
Pressure Range (bar)
SHP502
-0.5 ~ 2
0.2 ~ 0.7
SHP503
-0.5 ~ 3
0.35 ~ 1.5
2
1
16.5
SHP506
-0.5 ~ 6
0.6 ~ 4
3
2
16.5
SHP506M
-0.5 ~ 5.5
≤1
Manual Reset
2
16.5
SHP110
1 ~ 10
1~3
6
5
16.5
SHP516
5 ~ 16
2~5
10
8
33
16.5
SHP520
5 ~ 20
2~5
16
14
33
SHP530D
5 ~ 30
3 ~ 10
20
15
33
SHP530
8 ~ 30
3 ~ 5 ( Fixation )
20
15 ~ 17
33
SHP530M
8 ~ 30
≤5
20
Manual Reset
33
DOUBLE PRESSURE CONTROL
• Maximum bellows testing pressure: Low 16.5 bar, high 33 bar; • Scale plate use “bar” & “psig” units • Could be use “MPa” , “ kgf/cm2” units also as customer requirement. • Connection could as customer requirement use British unit flare(E), solder(S) and capillary(C)such as SHP830E; • Ammonia refrigerant model added a code B, such as SHP830B.
RANG E AC 250V-8A AC 125V-15A
bar
30 25 20 15 10 8
PSi
435 363 290 218 145 115
M.W.P 33bar/471psig
Rated Voltage(V) Rated Amps(A) Non-Inductive Current Full Load Current Inductive Current Locked Roter Low pressure(bar) Model
125V AC
250V AC
24 V DC
20A 15A 72A
10A 8A 72A
10A 8A 64A
High Pressure(bar)
Reset Pressure (bar)
Factory Setting (bar) Low Pressure
High Pressure
Pressure Range
Differentral Pressure
Pressure Range
Differential Pressure
Low Pressure
High Pressure
Fig.1
Fig.2
Fig.1
Fig.2
SHP830
-0.5 ~ 6
0.6 ~ 4
8 ~ 30
3 ~ 5 (Fix)
Auto
Auto
3
2
20
15
SHP830HM
-0.5 ~ 6
0.6 ~ 4
8 ~ 30
≤5
Auto
Manual
3
2
20
Manual Reset
SHP830HLM
-0.5 ~ 5.5
≤1
8 ~ 30
≤5
Manual
Manual
Manual Reset
2
20
Manual Reset
Note: Maximum bellows testing pressure: Low 16.5 bar, high 33 bar, Scale plate use “bar” & “psig” units ; Could be use “MPa” , “ kgf/cm2 ” units also as customer require. Connection could as customer require use British unit flare(E), solder(C) and capillary(S), such as SHP830E; Ammonia refrigerant model added a code B, such as SHP8308.
www.sanhehvac.com
02
DIFFERENTIAL PRESSURE CONTROL
Features • Differential pressure is adjustable type; • Model Options: controlling throughput of condensed water and cotrolling compressor oil pressure protection; • Non-delay devices of differential pressure control.
Inductive Current
Rated Voltage(V) Rated Amps(A) Non-Inductive Current Full Load Current Locked Roter Differential Adjust Range (bar) 0.5 ~ 2 0.5 ~ 3.5 0.5 ~ 3.5 1~6 1~6
Model SHD502 SHD504 SHD504H SHD106 SHD106H
Factory Setting (bar) 0.5 1 1 1 1
125V AC
250V AC
24 V DC
20A 15A 72A
10A 8A 72A
10A 8A 64A
Max. Working Pressure (bar) 17 17 30 17 30
Description Micro differential -----
Scale boards use “bar·, and “psig” two kinds of measurement units; Can be according to the customer requires use “MPa”, “kgf/cm2 ” Measurement units. Interface based on customer require: Inch screw type. add “E”, type welding model added “c”, capillary model added “s” such as SHD106E. Ammonia refrigerant type in the model. add “s”. shch as SHD106B
DELAY TIME DIFFERENTIAL PRESSURE CONTROL SHD series of delay differential pressure control is a protection controller, which can effectively protect the compressor oil pressure and always maintain a high-pressure state to avoid the damage of the compressor crankshaft due to the oil shortage; lf the oil pressure does not reach the set value within the set time, the controller will immediately cut off the power and stop compressor.
Rated Voltage (V)
125V AC
250V AC
24V DC
Non-Inductive Current
20A
10A
10A
Full Load Current
15A
8A
8A
Locked Roter
72A
72A
64A
Inductive Current
03
Model
Pressure Adjust Range (bar)
Switch Difference
Factory Setting (bar)
Delay Time
Max. Working Pressure (bar)
SHD35T
0.5 ~ 4
≤0.4
1
60s / 90s
16.5
SHD35TH
0.5 ~ 4
≤0.4
1
60s / 90s
33
SINGLE PRESSURE CONTROL
SH55 Series pressure switches are used to control the pressure of compressor in refrigerant system, also available in air or water fluid. This series have quite stable performance with internal micro-switch structure. Standard mounting bracket are provided
Rated Voltage (V) Full Load Current Inductive Current Locked Roter Temperature
125V AC 20A 72A
Range (bar)
Model
Min -0.2 2 8 8
SH5508 SH5514 SH5532 SH5542
250V AC 10A 72A -20 ~ 110ยบC
Differential (bar) Min Max 0.7 4 1 4 2 6 4 10
Max 7.5 14 32 42
24V DC 8A 64A
Factory Setting (bar) OFF ON 6 2 10 8 20 17 30 25
Max Operating Pressure (bar) 20 20 35 46.5
DOUBLE PRESSURE CONTROL Contact Function
Arrow means the direction of pressure increasing, M means hand reset
Rated Voltage (V) Full Load Current Locked Roter Temperature
Inductive Current
Model SH5832
SH5832HM
SH5832HLM
D 250V AC 50VA 4A
24V DC 8A 64A -20 ~ 110ยบC
Min
Range (bar) Max
Low Side
-0.2
7.5
High Side
8
32
Low Side
-0.2
7.5
High Side
8
32
Low Side
-0.2
High Side
8
Pressure Side
B-C 250V AC 10A 72A
125V AC 20A 72A
Differential (bar) Min Max 0.7
4
Factory Setting (bar) OFF ON
Max Operating Pressure (bar)
4
2
20
20
15
35
4
2
20
Fixed 4
20
Manual Reset
35
7.5
Fixed 4
3
Manual Reset
20
32
Fixed 4
20
Manual Reset
35
Fixed 4 0.7
4
www.sanhehvac.com
04
THERMOPLASTIC CAPILLARY HOSE
Features • • • • •
High elasticity No more brazing, flaring and bending of copper tubes. Time saving for system installation and assembling. Protection class IP65, insulation class H level. Very low refrigerating gas permeation rate.
Assembly Instructions
1
2
3
4
5
6
1. Cut the hose using proper shears,automatic or manual cutters.The cut must be per fectly square and smooth. 2. Insert the sleeve on the hose with the groove towards the hose side to be assembled 3. Insert the nut onto the hose. 4. Push the insert inside the hose 5. Make the nut slide onto the external part of the insert(flare) and push the sleeve till it covers the bottom of the free insert. 6. Assemble the hose by positioning manual pliers on the sleeve covering its whole surface. Crimp till hand pliers poen automatically.A second crimping is useful to obtain a safer assembling.
Fittings and Accessories
90%insert with nut
Straight insert with nut
T fitting
Copper gasket
Straight insert
Sleeve
Note: Available in any combination of 1/4" or 3/8" brass SAE flare straight or 90° angel fittings.
Thermoplastic Hose ID 2mm Model
Colour
Inner Diametre
Outer Diametre
Tolerances
Min Bending Radius
Working Pressure
Working Temp
Weight
TCH2 TCH2-B TCH2-R
Black Blue Red
2.0 mm 2.0 mm 2.0 mm
5.9 mm 5.9 mm 5.9 mm
0.1 mm 0.1 mm 0.1 mm
10 mm 10 mm 10 mm
45 bar 45 bar 45 bar
-40ºC ~ 130ºC -40ºC ~ 130ºC -40ºC ~ 130ºC
30 g/m 30 g/m 30 g/m
Thermoplastic Hose ID 4mm
05
Model
Colour
Inner Diametre
Outer Diametre
Tolerances
Min Bending Radius
Working Pressure
Working Temp
Weight
TCH4 TCH4-B TCH4-R
Black Blue Red
4.0 mm 4.0 mm 4.0 mm
8.2 mm 8.2 mm 8.2 mm
0.1 mm 0.1 mm 0.1 mm
35 mm 35 mm 35 mm
45 bar 45 bar 45 bar
-40ºC ~ 130ºC -40ºC ~ 130ºC -40ºC ~ 130ºC
50 g/m 50 g/m 50 g/m
SIGHT GLASS
Model SGS-7 SGS-9 SGS-11 SGS-13 SGS-17 SGS-33
Connector Specification 7/8" ODM 1-1/8" ODM 1-3/8" ODM 1-5/8" ODM 2-1/8" ODM 4-1/8" ODM
Rn (mm)
Model
11 14.2 17.5 20.64 27 52.4
SGS-S13U
Window Connected Screw Diameter(mm) 24 1-5/8”-12UNF
SGS-S10U
19
SGS-S14U
27
1-1/4”-12UNF 1-3/4”-12UNF
SGS-S18U
36.3
2-1/4”-12UNF
SGS-S22U
44.5
2-3/4”-12UNF
Male SAE to Male SAE Model SGN-2 SGN-3 SGN-4 SGN-5 SGN-6
Connector Specification 1/4" SAE 3/8" SAE 1/2" SAE 5/8" SAE 3/4" SAE
L (mm) 64 70 78 78 94
H (mm) 23 24 28 29 32
B (mm) 7/16"-20UNF 5/8"-18UNF 3/4"-16UNF 7/8"-14UNF 1-1/16"-14UNF
L (mm) 65 65 70 80
H (mm) 23 24 30 32
B (mm) 7/16"-20UNF 5/8"-18UNF 3/4"-16UNF 7/8"-14UNF
Male SAE to Female SAE Model SGN-2FS SGN-3FS SGN-4FS SGN-5FS
Connector Specification 1/4" MxF 3/8" MxF 1/2" MxF 5/8" MxF
Female ODS to Female ODS Model SGN-2S SGN-3S SGN-4S SGN-5S SGN-6S SGN-7S SGN-9S
Connection Specification 1/4" (06mm) 3/8" (10mm) 1/2" (12mm) 5/8" (16mm) 3/4" (18mm) 7/8" (22mm) 1-1/8" (28mm)
L (mm) ODS ODS ODS ODS ODS ODS ODS
L1 (mm) 100 118 145 145 160 172 172
H (mm) 23 23 28 29 32 40 40
A (mm) 6.35 (6) 9.52 (10) 12.7 (12) 15.88 (16) 19.05 (18) 22.22 (22) 28.57 (28)
Male SAE to Male SAE Model SG-2 SG-3 SG-4 SG-5 SG-6
Connector Specification 1/4" SAE 3/8" SAE 1/2" SAE 5/8" SAE 3/4" SAE
L (mm) 58 70 80 80 90
H (mm) 23 28 31 34 34.3
B (mm) 7/16"-20UNF 5/8"-18UNF 3/4"-16UNF 7/8"-14UNF 1-1/16"-14UNF
Female ODS to Female ODS Model SG-2S SG-3S SG-4S SG-5S SG-6S SG-7S
Connector Specification 1/4"(06mm) ODS 3/8"(10mm) ODS 1/2"(12mm) ODS 5/8"(16mm) ODS 3/4"(18mm) ODS 7/8"(22mm) ODS
L (mm) 100 120 124 124 140 160
L1(mm) 8 10 12 14 14 15
H (mm) 23 28 31 33 34.3 46
A (mm) 6.35 (6) 9.52 (10) 12.7 (12) 15.88 (16) 19.05(18) 22.22(22)
www.sanhehvac.com
06
BV SERIES BALL VALVE
Features • • • • • • • • •
L1
No pressure drop in flow. Only turn 1/4 circle to make valve full open or full close. Turning stop for full open or full close. Two-direction flow is available. Argon arc welded structure. Explosion-proof valve stem design. Modified PTFE sealing. Inside liquid accumulation is avoided. Could be mounted on the control panel.
L
Specification Appicable Refrigerant Appicable Medium Temperature (PS/MWP) Max. Opening Pressure Max. Allowable Pressure Yearly leakage of Refrigerant Certification
CFC . HCFC. HFC. HC -40ºC ~ +150ºC 45bar (653psig) 65bar (943psig) ≤ 2g R22/a UL
Type
Connection Size(in)
L (mm)
L1 (mm)
Type
Connection Size(in)
L (mm)
L1 (mm)
BV-06
1/4"
144
7
BV-06S
1/4"
144
7
BV-10
3/8"
144
8
BV-10S
3/8"
144
8
BV-12
1/2"
160
11
BV-12S
1/2"
160
11
BV-16
5/8"
160
15
BV-16S
5/8"
160
15
BV-18
3/4"
186
20
BV-18S
3/4"
186
20
BV-22
7/8"
186
20
BV-22S
7/8"
186
20
BV-28
1-1/8"
214
23
BV-28S
1-1/8"
214
23
BV-35
1-3/8"
248
25
BV-35S
1-3/8"
248
25
BV-42
1-5/8"
280
28
BV-42S
1-5/8"
280
28
BV-54
2-1/8"
304
33
BV-54S
2-1/8"
304
33
BV-67
2-5/8"
305
37
BV-67S
2-5/8"
305
37
BV-79
3-1/8"
380
40
BV-79S
3-1/8"
380
40
BV-89
3-1/2"
410
40
BV-89S
3-1/2"
410
40
BV-92
3-5/8"
410
40
BV-92S
3-5/8"
410
40
Two types of BV ball valve are available :with and without the charging port . The part number which with “’s” has the charging port.
07
STANDARD BALL VALVE
Features • • • • • • • • •
No pressure drop in flow. Only turn 1/4 circle to make valve full open or full close. Turning stop for full open or full close. Two-direction flow is available. Argon arc welded structure. Explosion-proof valve stem design. Modified PTFE sealing. Inside liquid accumulation is avoided. Could be mounted on the contral panel.
Specification Appicable Refrigerant
CFC . HCFC. HFC. HC
Suitable Temperature
-40ºC ~ +140ºC
The Maximum Working Air Pressure
4.5 Mpa
Hydraulic Pressure
6.8 Mpa
Certification
UL
Model
ODS
ΦD
B
H
L
Standard
With a Chargeing Port
inch
mm
mm
mm
mm
SH-17202
SH-17402
1/4"
SH-17203
SH-17403
3/8"
Φ10
10
28.5
126
SH-17204
SH-17404
1/2"
SH-17205
SH-17405
5/8"
SH-17206
SH-17406
3/4"
Φ13
12
30.5
150
SH-17207
SH-17407
7/8"
SH-17209
SH-17409
1-1/8"
Φ18.5
20
40.5
189
SH-17211
SH-17411
1-3/8"
SH-17213
SH-17413
1-5/8"
Φ31
25
51
245
SH-17217
SH-17417
2-1/8"
Φ48
30
64.5
319
SH-17221
SH-17421
2-5/8"
Φ58
35
81.5
380
SH-17225
SH-17425
3-1/8"
Φ71
91.5
410
SH-17233
SH-17433
4-1/8"
Φ94
115
450
40
www.sanhehvac.com
08
HAND VALVE
Hand valve is one kind of manual stop valve and applied to one-way flow.It is used for the liquid of freezing, refrigeration and air conditioning systems and also installe in inhaling &heating pipes.
Features • With nylon valve core, durable sealing surface,long service life. • With a stainless steel diaphragm which can avoid leaking during service life. • Applicable refrigerant medium: For R22, R134A, R410A, R502, R407C etc. • Medium temperature:-25°C ~ +100°C • Maximum working pressure:4.5MPa • Just turn one and a half circle to make the valve full open or full closed.
Specification Model SH-B-02H SH-B-02 SH-B-03H SH-B-03 SH-B-04H SH-B-04 SH-B-05H SH-B-05 SH-B-06H SH-B-06 SH-B-07H SH-B-07
09
Specification 1/4" 3/8" 1/2" 5/8" 3/4" 7/8"
Connection Thread
Dimension(mm) B
C
ODF
60
6
SAE
58
13
ODF
52
5.5
SAE
60
13
D
E
66
35
84
41.3
ODF
80
6
SAE
81
17
ODF
82
7.5
SAE
84
17
ODF
85
8.5
SAE
87
17.4
ODF
83
12.4
84
41.3
SAE
105
24
110
50
MAGNETIC CHECK VALVE CV type magnetic check valve is designed with a permanent magnet, and a diaphragm with steel core, which has coated with modified NBR on surface. The diaphragm is compatible to many refrigerants and has a perfect sealing performance. The valve can be used in liquid line and exhaust line of compressor, and can be mounted with any angel due to its special design.
Features • • • • • • • • • • • •
Multi orientation while maintaining flow direction Hermetic spun copper body design Designed for maximum flow and minimal pressure drop Valve diaphragm coated with Neoprene Built-in 30 mesh stainless steel screen Copper connection sizes 1 /4” through 3-1 /8” Stable, Zero leak Negligible loss in system efficiency Efficient sealing with a negligible leak rate Able to be installed in any position Filt function to extend the valve service life Suitable for a wide range of applications, including combination (muffler/check valve)
Model
ConnectorSize (A)
Shell Body (C)
Length (B)
Mesh No.
SWP(Kpa)
Leakage Rate @420 kPa (cm3/sec)
Kv(m3/Hr)
CV-04
1/4
22
102
30
5500
<0.00025
0.47
CV-06
3/8
22
102
30
5500
<0.00025
0.99
CV-08
1/2
22
102
30
5200
<0.00056
0.99
CV-08B
1/2
29
127
30
5200
<0.00056
2.67
CV-10
5/8
22
102
30
5200
<0.00056
2.98
CV-10B
5/8
29
127
30
5200
<0.00056
2.98
CV-12
3/4
29
127
30
4100
<0.00123
5.56
CV-12B
3/4
41
178
30
4100
<0.00123
5.56
CV-14
7/8
29
127
30
4100
<0.00123
7.58
CV-14B
7/8
41
178
30
4100
<0.00123
7.58
CV-18
1-1/8
41
213
30
4100
<0.00203
13.19
CV-18B
1-1/8
54
213
30
4100
<0.00203
13.19
CV-22
1-3/8
54
213
30
4000
<0.00287
16.26
CV-26
1-5/8
54
213
30
3000
<0.00453
27.78
CV-34
2-1/8
92
305
30
3200
<0.00643
48.27
CV-42
2-5/8
105
330
30
3000
<0.00853
64.76
CV- 50
3-1/8
105
330
30
3000
<0.00995
80.95
www.sanhehvac.com
10
PLUNGER CHECK VALVE Features • Max. working pressure: 4.8MPa. • Working media: R22, R134a, R410a, POE refrigerant oil, water, steam and fluorine refrigerants. • Working temperature: -40ºC ~ +150ºC • Small size, easy to mount/unmount. • Good anti-vibration and sealing performance, easy to use. • Sealed by imported PTFE: good sealing performance and long durability.
Model
ODS (inch.)
SH-3120/6 SH-3120/7 SH-3120/9 SH-3120/11 SH-3120/13 SH-3120/17
3/4" 7/8" 1-1/8" 1-3/8" 1-5/8" 2-1/8"
DN (mm) Φ25 Φ32 Φ38 Φ48
B (mm) 18 20 22 25 30
H (mm)
M (mm)
27 34.5 37 42
M10
L (mm)
C (mm)
100
86
118 141 172
103 127 137
Note: The valve should be mounted according to the flow direction marked on the valve body.
GLOBE VALVE Globe valve could be installed in commercial refrigeration system, civil and industrial air-conditional systems. The spindle is automatic closed,it can be installed in any position which needs to change the direction.
Features • Vlave plate of polyamide nylon to give complete shutoff with minimum torque. • Valve handle with special design,can be shut-off without the use of tools. • Adapt to R22,R502,R134a,R407C,R410,R404a,R600a refrigerants and so on. • Maximum working prossure: 4.5Mpa(Air); 6.8Mpa (Hydraulic) • Working temperature: -40ºC ~ +140ºC
Model
ODS (inch.)
SH-6510/7 SH-6510/9 SH-6510/11 SH-6510/13 SH-6510/17
7/8" 1-1/8" 1-3/8" 1-5/8" 2-1/8"
DN (mm) Φ25 Φ32 Φ38 Φ48
B (mm)
H (mm)
20 22 25 30 30
27
Note: The valve should be mounted according to the flow direction marked on the valve body.
11
34 37 42
M (mm)
M10
L (mm)
C (mm)
100
132
118 141 172
140 160 174
ROTOLOCK VALVE
ODS
Model
Inch 3/8" 1-1/8" 1-3/8" 3/4" 7/8" 1/2" 7/8" 5/8" 5/8"
MLV01 MLV02 MLV03 MLV04 MLV05 MLV06 MLV07 MLV08 MLV09
mm 10 28 35 19 22 12 22 16 16
ODS
Model
Inch 3/8" 1-1/8" 1-3/8" 3/4" 7/8" 1/2" 7/8" 5/8" 5/8"
TKV01 TKV02 TKV03 TKV04 TKV05 TKV06 TKV07 TKV08 TKV09
Body 20
30
35
45
mm 10 28 35 19 22 12 22 16 16
Model
Rotolack Connection
Hex
Body
Length
1" -14UNS 1-3/4" 12UN 1-3/4" 12UN 1-1/4 " 12UNF 1-1/4 " 12UNF 1" -14UNS 1-3/4 " 12UNS 1" -14UNS 1-1/4 " 12UNF
30 50 50 36 36 30 50 30 36
20 X 20 35 X 35 35 X 35 30 X 30 30 X 30 20 X 20 30 X 30 20 X 20 20 X 20
135 195 195 160 160 135 160 135 135
Rotolack Connection
Hex
Body
Length
1" -14UNS 1-3/4" 12UN 1-3/4" 12UN 1-1/4 " 12UNF 1-1/4 " 12UNF 1 " 14UNS 1-3/4 " 12UNS 1 " 14UNS 1-1/4 " 12UNF
30 50 50 36 36 30 50 30 36
20 X 20 35 X 35 35 X 35 30 X 30 30 X 30 20x20 30x30 20x20 20x20
105 173 175 135 135 110 135 110 110
ODS
Length (L)
ML001 ML002 ML003 ML004 ML005 ML006 ML007 ML008 ML009 ML010
inch 3/8" 1/2" 5/8" 3/4" 7/8" 1-1/8" 1-1/8" 1-3/8" 1-5/8" 1-3/8"
mm 10 12 16 19 22 28 28 35 42 35
ML011
1-5/8"
42
192
ML012
2-1/8"
54
194
105 109 105 135 135 172 172 190 192 190
www.sanhehvac.com
12
SPLIT VALVE Split valve is an important part of the split air conditioner, which is used for connecting the outdoor unit and the indoor unit. closing or openning the refrigerant circuit, extracting or fiIling refrigerant.
Features
Applicable Scope
• It is used to connect the outdoor units and indoor units, and play the role of switching. • Easy to operate, easy operation. • Use soft seal and hard seal to ensure the sealing performance.
• Applicablemedium: R22 , R134a, R410a, R407C, R32,etc. • Maximum working pressure: 4.2MPa. • Applicable medium temperature: -30ºC ~ +120ºC.
Model SV-01 SV-02 SV-03 SV-04 SV-05 SV-06 SV-07
Model SV-01B SV-02B SV-03B SV-04B SV-05B SV-06B
Model SV-02C SV-03C SV-04C SV-05C SV-06C SV-07C
Model SSV-03 SSV-04 SSV-05 SSV-06 SSV-07
13
Connection Size (in) 1/4" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8"
Connection Size (in) 1/4" 1/4" 3/8" 1/2" 5/8" 3/4"
Connection Size (in) 1/4" 3/8" 1/2" 5/8" 3/4" 7/8"
Connection Size (in) 3/8" 1/2" 5/8" 3/4" 7/8"
Remark Two Way
Three Way
Remark Two Way
Three Way
Remark
Three Way
Remark
Three Way
VIBRATION ABSORBER TUBE Metal hose, with excellent flexibility and vibration absorbing capacity due to being tightly covered by high intensitve protecting metal braid and fixed with two metal rings,then welded with copper socket, is used for connection between circulating tube and compressors of air-conditioners, refrigerators, congealers etc. to absorb vibration caused by the compressors and protect the whole tube system.
Features • • • •
Compatible with all CFC, HCFC and HFC refrigerants and oils. 100% leakage tested. Solid copper contruction. CE & UL certified.
Material Specification Item VA-014 ~ VA-418
Flexible Tubing SS304/ SS316/ Copper
Wire braid
Ferrule
Tube End
SS304/ SS316
SS304/ SS316/ Copper
SS304/ SS316/ Copper
Note:(1)Commonly used materials of our Vibration Absorber: Flexible Tubing:SUS304; Wire Braid:SUS304; Ferrule:SUS304; Tube End:Copper TP2; (2)If other materials are needed(except ones in the table above), please kindly specify in advance.
Specifications ETL Certificated Dimensions ( inch ) E
Working Pressure(psig)
Burst Pressure(psig)
200mm
1/2"
650
3250
8-1/2"
217mm
1/2"
650
3250
7-1/4"
9"
228mm
1/2"
650
3250
15/16"
8"
9-7/8"
250mm
7/8"
650
3250
3/4"
1/4"
8-1/16"
10-1/2"
268mm
7/8"
650
3250
VA-078
7/8"
1-3/8"
9-1/4"
12"
305mm
7/8"
650
3250
VA-100
1"
1-3/4"
9-7/16"
13"
332mm
7/8"
650
3250
VA-118
1-1/8"
1-3/4"
9-7/16"
13"
332mm
7/8"
650
3250
VA-138
1-3/8"
2-1/16"
11-7/16"
15-1/2"
395mm
7/8"
550
2750
VA-158
1-5/8"
2-1/4"
12-3/8"
16-15/16"
429mm
1"
510
2550
VA-218
2-1/8"
2-11/16"
15-3/16"
20-1/2"
524mm
1-3/8"
400
2000
VA-258
2-5/8"
3-1/16"
18"
24-1/8"
617mm
2"
350
1750
VA-318
3-1/8"
3-7/16"
20"
26-15/16"
684mm
2"
320
1600
VA-358
3-5/8"
4-1/16"
24"
32-1/8"
818mm
2"
190
570
VA-418
4- 1/8"
4-1/2"
24"
33"
836mm
2"
190
570
Model
A
B
C
D
VA-014
1/4"
1/2"
6-1/2"
7-7/8"
VA-038
3/8"
3/4"
7"
VA-012
1/2"
7/8"
VA-058
5/8"
VA-034
www.sanhehvac.com
14
SH SERIES SOLENOID VALVE Features • Only NC type solenoid valve is available. • It is applicable to various applications in freezing, cold storage and air conditioner units. • The solenoids of different power supply are available. • The thread capped solenoid is easy to be manually mounted and dismounted. • SH series solenoid valve is a direct-operated or servo-operated valve, which is applicable to one direction flow. • The valve seat of SH series solenoid valve is well sealed with perfect sealing performance. • Various voltage options are for solenoid while the valve body is universal. • Both integrated and separated SH series solenoid valves are available.
Applicable Refrigerant
HCFC and HFC (Customer choice)
Applicable Medium Temperature
-25ºC ~ +105ºC
Max. Operating Pressure
3.0MPa
Min. Pressure Differential to Open Valve
Direct-operated: 0.00MPa; Servo-operated: 0.02MPa
Max. Operating Pressure Differential ( MOPD)
2.5MPa
Applicable Ambient Temperature for Solenoid
-25ºC ~ +60ºC
Standard Voltage of Solenoid
AC380V, AC220V/50Hz(Custom-design is available)
Allowable Voltage Fluctuation for Solenoid
+10%--15%
Solenoid Coil
8W
Connection Model
15
Nominal Refrigerating Capacity kW (liquid)
Flare
Welded
SH-1020/2
1/4" SAE
--
SH-1028/2
--
1/4" ODF
SH-1020/3
3/8" SAE
--
SH-1028/3
--
3/8" ODF
SH-1064/3
3/8" SAE
--
SH-1068/3
--
3/8" ODF
SH-1064/4
1/2" SAE
--
SH-1068/4
--
1/2" ODF
SH-1068/5
--
5/8" ODF
SH-1070/4
1/2" SAE
--
SH-1078/4
--
1/2" ODF
SH-1070/5
5/8" SAE
--
SH-1078/5
--
5/8" ODF
SH-1078/6
--
SH-1098/7
--
Kv ( m3/h)
R22
HFC-134a
R404a/R502
0.175
3.15
2.95
2.08
0.230
4.15
3.90
2.75
0.800
14.5
13.50
9.50
0.800
14.5
13.50
9.50
2.200
39.6
37.10
26.20
2.610
47.00
44.00
31.00
3/4" ODF
4.300
77.50
72.045
51.10
7/8" ODF
5.700
102.60
96.00
67.85
EVR SOLENOID VALVE Features • Only NC type solenoid valve is available. • 100-mesh filter is contained at the suction end, which is replaceable. • (MOPD) is 3.0 MPa. • It is applicable to various applications in freezer, cold store and air conditioning unit. • It is applicable to various applications in freezer, cold store and air conditioning unit. • It is applicable to various applications in freezer, cold store and air conditioning unit.
Applicable Refrigerant Applicable Medium Temperature Applicable Ambient Temperature Of Solenoid Standard Voltage Of Solenoid Allowable Voltage Fluctuation For Solenoid Connection Of Solenoid Model EVR3-2 EVR3-3 EVR6-3 EVR6-4 EVR10-4 EVR10-5 EVR15-5 EVR15-6 EVR15-7 EVR20-7 EVR20-9 EVR25-9 EVR25-11 EVR32-11 EVR32-13 EVR40-13 EVR40-17
Connection Type Flare Welded 1/4 SAE 1/4 ODF 3/8 SAE 3/8 ODF 3/8 SAE 3/8 ODF 1/2 SAE 1/2 ODF 1/2 SAE 1/2 ODF 5/8 SAE 5/8 ODF 5/8 SAE 5/8 ODF 3/4 SAE 3/4 ODF -7/8 ODF -7/8 ODF -1-1/8ODF -1-1/8ODF -1-3/8ODF -1-3/8ODF -1-5/8ODF -1-5/8ODF -2-1/8ODF
Min. 0 0
R22
R134a R404A/R507
P ( bar) Max.MOPD Liquid
Max. Operating Pressure ( bar)
Kv(m3/h) 0.27 0.27 0.8 0.8 1.9 1.9 2.6 2.6 2.6 5 5
0.05 30
40
10.5 0.2
16 21
Nominal Refrigerating Capacity (kW) Vapour
Liquid
Model
HCFC or HFC ( Customer choice) -25ºC ~ + 105ºC -25ºC ~ +80ºC AC380V, AC220V/50Hz ( Custom design is available) +10% ~ -15% IP65 with terminal box
R407C
R22
R134a R404A/R507
R407C
Hot Gas R22
R134a
R404A/R507
R407C
EVR3
5.40
5.00
3.80
5.08
--
--
--
--
2.50
2.00
2.00
2.43
EVR6
16.10
14.80
11.20
15.13
1.80
1.30
1.60
1.60
7.40
5.90
6.00
7.18
EVR10
38.20
35.30
26.70
35.91
4.30
3.10
3.90
3.96
17.50
13.90
14.30
16.98
EVR15
52.30
48.30
36.50
49.16
5.90
4.20
5.30
5.43
24.00
19.00
19.60
23.28
EVR20
101.0
92.80
70.30
94.90
11.40
8.10
10.20
10.49
46.20
36.60
37.70
44.81
EVR22
121.0
112.0
84.30
113.7
13.70
9.70
12.20
12.60
55.40
43.90
45.20
53.74
EVR25
201.0
186.0
141.0
188.9
22.80
16.30
20.40
20.98
92.30
73.20
75.30
89.53
EVR32
322.0
297.0
225.0
302.5
36.50
26.10
32.60
33.58
148.0
117.0
120.0
143.56
EVR40
503.0
464.0
351.0
472.7
57.00
40.80
51.00
52.44
231.0
183.0
188.0
224.07
www.sanhehvac.com
16
SHF IMPROVED SOLENOID VALVE Features • • • • • •
Refrigerant:R12,R22;R134a,R404,R407C,R410,R502 Suitable Temperature: -30ºC ~ +105ºC Service Life: 100,000 cyeles Working Pressure: 3.0MPa Solenoid Coil: 12W SHF series solenoid valve is one upgraded version of SH series. • The valve is widely used in refrigeration compressor group, central air-conditioning, coldstorage equipment and bus air-conditioning system.
Model
Operating Principles
mm SHF2-02 SHF2-02S SHF3-03 SHF3-03S SHF7-03 SHF7-03S SHF7-04 SHF7-04S SHF8-03 SHF8-03S SHF10-04 SHF10-04S SHF13-05 SHF13-05S SHF16-06S SHF19-07S
Connection Size
Port Size
2.5 Direct Acting 3
7
8
Diaphragm Pilot Operated
10 13 16 19
SAE in. 1/4" -3/8" -3/8" -1/2" -3/8" -1/2" -5/8" ----
ODF mm --------10 -12 -16 ----
in. -1/4" -3/8" -3/8" -1/2" -3/8" -1/2" -5/8" 3/4" 7/8"
mm ---------10 -12 -16 19 22
Opening Pressure Differential (Bar) Max. Min. A.C. D.C. 21 19 21 19 0 21 19 21 19 21 19 21 19 21 19 21 19 21 17 21 17 0.05 21 17 21 17 21 17 21 17 21 17 21 17
Dimension (mm) Length 58 107 58 107 72 118 72 108 85 125 85 125 89 150 185 190
Width 24 24 24 24 30 30 30 30 45 45 45 45 45 45 60 60
Height 84 84 84 84 90 90 90 90 97 97 97 97 97 97 120 120
FDF SERIES SOLENOID VALVE Features • • • • • • • • •
Model FDF-2A FDF-3A FDF-4A FDF-6A FDF-8A
Movement Pattern
Diameter (mm)
Flow
Normally Close
Φ1.9 Φ3.0 Φ4.0 Φ6.0 Φ8.0
38 110 196 367 450
Note: Available with straight - thru or right angle design
17
Rated Voltage: AC220V, AC110V, DC24V Frequency: 50/60Hz Refrigerant: R22, R407C, R410A,etc. Maximum pressure:4.2Mpa Voltage:ranges from 85% to 110% of rated voltage Medium temperature:-30ºC ~ 120ºC Ambient temperature:-30ºC ~ 50ºC Relative humidity: 95% or less Movement Pattern: Normally Closed; Normally Open(Custom-made).
Internal Leakage Max. working Connection Size (mL/min) pressure (Mpa) (mm) ≤100 4.2 Φ6 ≤300 4.2 Φ8 ≤500 4.2 Φ6 ≤500 4.2 Φ8 ≤500 4.2 Φ8
Motion type Normal close Normal close Normal close Normal close Normal close
ST2/STE2 THERMAL EXPANSION VALVE Features • Application: regulating the flow rate of refrigerant into evaporators; • Type options: internal equalizer and external equalizer systems; • Orifice: Interchangeable; • Evaporator temperature: -40ºC ~ +10ºC.
Ordering Code Connection Type
Equalization
R12
R134A
R22
R404A R507
R407C
Internal
STF2
STN2
STX2
STS2
STZ2
External
STEF2
STEN2
STEX2
STES2
STEZ2
Internal
HTF2
HTN2
HTX2
HTS2
HTZ2
SAE Flare
ODF Solder
External
HTEF2
HTEN2
HTEX2
HTES2
HTEZ2
Specification Model
Equalization
ST2
Internal
STE2
External
HT2
Internal
HTE2
External
Connection Inlet x Outlet inch mm
Connection Type
Equalization connection
Capillary Length(m)
1/4 (6mm)
1
SAE Flare 3/8 x 1/2
10 x 12
ODF Solder
Nominal Refrigerating Capacity(-40ºC~ +10ºC) Orifice Size
R22
R407C
R134a
R404A/R507 KW
TR
KW
TR
KW
TR
KW
TR
0X
0.15
0.5
0.16
0.5
0.11
0.4
0.11
0.38
00
0.3
1
0.3
1.1
0.25
0.9
0.21
0.7
01
0.7
2.5
0.8
2.7
0.5
1.8
0.45
1.6
02
1.0
3.5
1.1
3.8
0.8
2.6
0.6
2.1
03
1.5
5.2
1.6
5.6
1.3
4.6
1.2
4.2
04
2.3
8
2.5
8.6
1.9
6.7
1.7
6.0
05
3.0
10.5
3.2
11.3
2.5
8.6
2.2
7.7
06
4.5
15.5
4.9
16.7
3.0
10.5
2.6
9.1
Remark: Nominal refrigerating capacity is based on the condensing temperature 32ºC, evaporating temperature 5ºC
www.sanhehvac.com
18
NRF(E)/RT(E) SERIES EXPANSION VALVE
Features • • • • •
Stable superheat setting Evaporating temperature range: -40ºC+10ºC MOP (Max. operating pressure) function is available Changeable inlet filter net Suitable for R22, R134a, R407c, R404A/R507
Superheat Adjusting Factory setting :superheat 3.5K,static superheat adjusting range is between 2~8K. Take off cap and turn adjusting stem. Turn adjusting stem anticlockwise one round,reduces superheat 1.5K.
R134a Model
R22 Nominal Capacity (KW)
Model
Nominal Capacity (KW)
NRF(E) RT(E)
1/4M
0.88
NRF(E) RT(E)
1/2H
1.76
NRF(E) RT(E)
1/2M
1.76
NRF(E) RT(E)
1H
3.52
NRF(E) RT(E)
1M
3.52
NRF(E) RT(E)
1-1/2H
5.28
NRF(E) RT(E)
1-1/2M
5.28
NRF(E) RT(E)
2H
7.04
NRF(E) RT(E)
2M
7.04
NRF(E) RT(E)
3H
10.56
NRF(E) RT(E)
2-1/2M
8.80
NRF(E) RT(E)
4H
14.08
NRF(E) RT(E)
3M
10.56
NRF(E) RT(E)
5H
17.60
NRF(E) RT(E)
4M
12.32
NRF(E) RT(E)
6H
21.12
NRF(E) RT(E)
5-1/2M
19.36
NRF(E) RT(E)
7-1/2H
26.40
NRF(E) RT(E)
7-1/2M
26.40
NRF(E) RT(E)
10H
35.20
NRF(E) RT(E)
9M
31.68
NRF(E) RT(E)
12H
42.24
Note :Nominal capacity is based on evaporating temperature te=4.4ºC, condensing temperature tc=40ºC, and refrigerant temperature ahead of valve t1= 38ºC
R407c Model
R404A/R507 Nominal Capacity (KW)
Model
Nominal Capacity (KW)
NRF(E) RT(E)
1/2N
1.76
NRF(E) RT(E)
1/3S
1.17
NRF(E) RT(E)
1N
3.52
NRF(E) RT(E)
2/3S
2.35
NRF(E) RT(E)
1-1/2N
5.28
NRF(E) RT(E)
1S
3.52
NRF(E) RT(E)
2N
7.04
NRF(E) RT(E)
1-1/2S
5.28
NRF(E) RT(E)
3N
10.56
NRF(E) RT(E)
2S
7.04
NRF(E) RT(E)
4N
14.08
NRF(E) RT(E)
3S
10.56
NRF(E) RT(E)
5N
17.6
NRF(E) RT(E)
3-1/2S
12.32
NRF(E) RT(E)
6N
21.12
NRF(E) RT(E)
4S
14.08
NRF(E) RT(E)
7-1/2N
26.4
NRF(E) RT(E)
5S
17.60
NRF(E) RT(E)
10N
35.2
NRF(E) RT(E)
7S
24.64
NRF(E) RT(E)
12N
42.24
NRF(E) RT(E)
8-1/2S
29.92
Note :Nominal capacity is based on evaporating temperature te=4.4ºC, condensing temperature tc=40ºC, and refrigerant temperature ahead of valve t1= 38º C
19
TCLE/TRFE SERIES EXPANSION VALVE
Naming Rule • Interchangeable orifice assembly ,easier stocking , easy capacity matching ,better service. • Stable superheat setting with bi-flow function. • MOP (Max. operating pressure) function is available. • Various connection type and size can be made according to customer’s requirement. • Suitable for R22, R134a, R407C, R404A/R507,R410A.
R134a
R22 Nominal capacity (KW)
Model
R407c Nominal capacity (KW)
Model
R404A/R507 Nominal capacity (KW)
Model
R410A
Nominal capacity (KW)
Model
Model
Nominal capacity (KW)
TCLE
1/4M
1.20
TCLE
1/2H
1.76
TCLE
1/2N
1.68
TCLE
1/3S
1.17
TCLE
2/3Z
2.20
TCLE
3/4M
2.29
TCLE
1H
3.52
TCLE
1N
3.49
TCLE
2/3S
2.35
TCLE
1-1/4Z
4.40
TCLE
1-1/2M
4.93
TCLE
2H
7.04
TCLE
2N
7.00
TCLE
1-1/2S
5.28
TCLE
2-1/2Z
8.80
TCLE
2-1/2M
10.91
TCLE
3H
10.55
TCLE
3N
10.23
TCLE
2S
7.04
TCLE
3-1/2Z
12.30
TCLE
3-1/2M
14.08
TCLE
5H
17.60
TCLE
5N
16.80
TCLE
3-1/2S
12.32
TCLE
6Z
21.10
TCLE
5-1/2M
19.36
TCLE
7-1/2H
26.40
TCLE
7-1/2N
25.75
TCLE
5S
17.60
TCLE
9Z
31.60
TCLE
7-1/2M
26.05
TCLE
10H
35.20
TCLE
10N
34.78
TCLE
7S
24.64
TCLE
12Z
42.20
TCLE
9M
30.72
TCLE
12H
42.24
TCLE
12N
41.85
TCLE
8-1/2S
29.92
TCLE
15Z
52.80
TRFE
11M
38.72
TRFE
14H
49.28
TRFE
14N
47.93
TRFE
10S
35.20
TRFE
17Z
60.00
TRFE
13M
45.76
TRFE
18H
63.36
TRFE
18N
61.59
TRFE
12S
42.24
TRFE
22Z
77.40
TRFE
16M
56.32
TRFE
22H
77.44
TRFE
22N
75.88
TRFE
15S
52.80
TRFE
26Z
91.50
TRFE
19M
66.36
TRFE
26H
91.52
TRFE
26N
90.79
TRFE
18S
63.36
TRFE
30Z
105.00
TRFE
25M
84.48
TRFE
35H
123.20
TRFE
35N
121.90
TRFE
25S
88.00
TRFE
42Z
147.80
TRFE
31M
105.6
TRFE
45H
158.40
TRFE
45N
156.78
TRFE
32S
112.64
TRFE
55Z
193.60
TRFE
45M
147.84
TRFE
55H
193.60
TRFE
55N
191.41
TRFE
38S
133.76
TRFE
65Z
228.80
TRFE
55M
193.60
TRFE
75H
264.00
TRFE
75N
262.50
TRFE
52S
183.04
TRFE
90Z
316.80
TRFE
68M
228.80
TRFE
100H
352.00
TRFE
100N
350.17
TRFE
70S
246.40
TRFE
100Z
352.00
TRFE
80M
280.60
TRFE
120H
420.70
TRFE
120N
416.70
TRFE
84S
295.70
TRFE
140Z
492.00
Note: Nominal capacity is based on evaporating temperature te=4.4ºC, condensing temperature tc=40ºC, and refrigerant temperature ahead of valve t1= 38ºC
www.sanhehvac.com
20
TB SERIES EXPANSION VALVE
Features • • • •
Model
Nominal capacity (kw) R134a R22
TB-1
0.50
0.70
TB-2
0.80
1.10
TB-3
1.00
1.40
TB-4
1.20
1.70
TB-5
1.60
2.80
TB-6
2.10
3.00
TB-7
3.10
4.40
TB-8
3.70
5.30
TB-11
4.90
7.00
TB-12
6.20
8.80
TB-13
7.20
10.20
TB-14
9.00
12.80
TB-15
9.50
14.00
TB-16
11.70
16.60
TB6-01
12.40
17.60
TB6-02
14.90
21.12
TB6-03
18.80
26.64
TB6-04
19.80
28.16
Type of equalization
Connection size
Capillary Length
Internal equalizated
ODF Inlet:1/4" Outlet:1/2"
1m 1.5m
Internal equalizated∆
ODF Inlet:1/2" Outlet:5/8"
1m 1.5m
Note: Condensing temperature +38ºC, evaporating temperature +5ºC; R134a: ∆P=0.46MPa, R22:∆P=0.69MPa.
21
Fixed static superheat temperature Suitable for small scale refrigeration system. ODF copper tube connections. Maximum working pressure: 2.8 MPa.
ELECTRONIC EXPANSION VALVE Features • S maller installation space: lower height, smaller volume, lower weight • High reliability • Low energy consumption • Suitable for reversible systems, such as heat pumps: bidirectional flow
Matching Fully PowOpen er(HP) Pulse "8.8( 2.5 )" 1.0 ~ 2.5 500 "7( 2.0 )" 1.0 ~ 1.75 500 "5.25( 1.5 )" 0.75 ~ 1.5 500 4.38( 1.25 ) 0.5 ~ 1.25 500 3.5( 1.0 ) 0.5 ~ 1 500
Model No.
DN R22 Capacity (mm) KW(USRT)
DPF(J) 2.0 DPF(J) 1.8 DPF(J) 1.6 DPF(J) 1.5 DPF(J) 1.3
Φ2.0 Φ1.8 Φ1.6 Φ1.5 Φ1.3
Open Valve Pulse 32±20 32±20 32±20 32±20 32±20
Max. Operating Pressure Pulse Difference(MPa) Frequency (PPS) R22 R407C R410a 30~90 2.26 2.48 3.43 30~90 2.26 2.48 3.43 30~90 2.26 2.48 3.43 30~90 2.26 2.48 3.43 30~90 2.26 2.48 3.43
CGX SERIES BYPASS VALVE
Connecting Pipe Size(mm) Φ6.35x0.7 Φ6.35x0.7 Φ6.35x0.7 Φ6.35x0.7 Φ6.35x0.7
Max. Working Pressure(Mpa) R22 R407C R410a 3 3.3 4.2 3 3.3 4.2 3 3.3 4.2 3 3.3 4.2 3 3.3 4.2
Features • Used in the refrigerating compressor set(without energy unloading device) to realize the systematic energy regulation. • Can be used as autometic expansion valve under fixed pressure to maintain the fixed evaporation pressure(temperature). • Can prevent the refrigerating compressor set from extract pressure decreasing lower than the minimum value. • Connecting means include flare with thread and ODF copper pipe welding. • Suitable mediums are various kinds of Freon and hydrocarbon compounds. • Maximum working pressure: 2.8 MPa. • To open or close within measure automatically when outlet pressure varies. • To ensure the outlet pressure constant on the set value in manual regardless the influence of the inlet pressure (within a certain range).
Model
Adjustment range
CGX-05 CGX-08 CGX-10 CGX-15 CGX-20 CGX-30
0 ~ 0.7 MPa
R134a 1. 5 2. 4 3.0 4. 2 5. 7 8. 5
Capability (KW) R22 2.8 4.5 5.6 8.4 11. 2 16. 8
R502 2.0 3.0 3.8 5.8 7.5 11. 7
Set pressure
ODF Connecting size
Weight (kg)
0 Mpa
Inlet : Φ8 x 1 Outlet : Φ10 x 1
0.15
www.sanhehvac.com
22
CBX SERIES BYPASS VALVE Features • The CBX hot gas-bypass valve is a kind of capacity adjust component for the refrigerating system with a non-adjustable compressor. • The CBX hot gas-bypass valve can be used as automatic expansion valve under fixed pressure to maintain the fixed evaporation pressure (temperature). • The CBX hot gas-bypass valve is capable of maintaining the minimum suction pressure. • ODF copper tube connections. • Suitable for HFC and HCFC. • Maximum working pressure: 28bar.
• CBX used as expansion valve under the fixed pressure. • CBX used as hot gas bypass valve to regulate capacity.
Model
Nominal capacity (kw) R407c R404A/507
R134a
R22
R410A
CBX-01
0.97
1.77
1.82
1.38
2.12
CBX-02
1.30
2.36
2.43
1.84
2.83
CBX-03
1.95
3.54
3.65
2.76
4.25
CBX-04
2.92
5.31
5.47
4.14
6.37
CBX-05
3.89
7.08
7.29
5.52
8.50
CBX-06
5.83
10.60
10.90
8.27
12.70
CBX-07
7.76
14.10
14.50
11.00
16.90
CBX-08
9.74
17.70
18.20
13.80
21.20
CBX-09
11.66
21.20
21.80
16.50
25.40
CBX6-01
13.60
24.70
25.40
19.30
29.60
CBX6-02
15.60
28.30
29.20
22.10
33.90
CBX6-03
17.50
31.80
32.80
24.80
38.20
CBX6-04
19.50
35.40
36.50
27.60
42.50
Note: Condensing temperature Te=3ºC, evaporating temperature Tc=38ºC; Refrigerant temperature ahead of valve: TL=37ºC; Subcooling: Tsub=1k;
23
Connection size
Inlet: φ8 ODF Outlet: φ12 ODM
Inlet:1/2" ODF Outlet:5/8" ODF
ELECTRONIC-DRAIN VALVE
Features
MIC-A
• Suitable for all applications, simple to install, fully automatic, maintenance-free. • Adjustable interval and discharge time and equipped with test button. • Pressure 16bar, various options for voltage and connection CE certification, patented products, protection class IP65, insulation class H level • Stainless steel valves, explosion-proof valve to choose from CE certification, patented products, protection class IP65, insulation class H level. • Equipped with ball valve filter, separated from the drain valve, with L-type structure. • Dimensions: 106 × 47 × 91mm, weight 570g
MIC-B
Timer
MICDRAIN
Time Interval (OFF)
0.5-45 Mins.
Discharge Time (ON)
0.5-10 Secs.
Manual Test Button
Micro Switch
Voltage
24-240V AC/DC 50/60Hz (Custom-made 380VAC)
Current Consumption
Max.: 4mA
Ambient Temperature
-40ºC ~ +60ºC
Protection Level
IP65
Shell Material
Flame-retardant ABS Plastic
Electrical Connection
DIN43650A
Indicator Light
LED(On/Off)
Valve
MIC-A
MIC-B
Type
2/2 directly operated valve
2/2 directly operated valve
Inlet / Outlet Dimensions
1/2" , 3/8" or 1/4"
1/2"
Maximum Working Pressure
16bar
16bar
Min. / Max. Ambient Temperature
2ºC/55ºC
2ºC/55ºC
Max. Medium Temperature
90ºC
90ºC
Valve Body
Forge Brass (Custom-made:Stainless Steel)
Forge Brass, Flow Aperture 1.0mm
Insulation Grade
Heat Resistance: Grade H
Heat Resistance: Grade H
Protection Level
IP65 (With Proper Installation)
IP65(With Proper Installation)
Voltage
24V ~ 230V AC/DC (Custom-made 380VAC)
24-230V AC/DC(Custom-made 380VAC)
Voltage Range
+/-10%
+/-10%
Installation Position
Random
Random www.sanhehvac.com
24
SEK MOLECULAR SIEVE LIQUID LINE FILTER DRIER • The automatic compressed device makes it possible to automatically fill in the wom molecules • High moisture and acid removal capacity • Motion of pads will not cause vibration • Drying and fiftering effect of combining • Filtration:20 microns • Two kinds of connection methods: ODF and SAE ;In order to facilitate welding. • ODF adoption of TP2 copper reserve • For a variety of refrigerant A-12. A-134a, A-22, R-404A, A-502 • Maximum working pressure: 4.5Mpa Connection Model SEK-032 SEK-032S SEK-033 SEK-033S SEK-052 SEK-052S SEK-053 SEK-053S SEK-082 SEK-082S SEK-083 SEK-083S SEK-084 SEK-084S SEK-162 SEK-162S SEK-163 SEK-163S SEK-164 SEK-164S SEK-165 SEK-165S SEK-167S SEK-303 SEK-303S SEK-304 SEK-304S SEK-305 SEK-305S SEK-306 SEK-306S SEK-307S SEK-309S SEK-413 SEK-414 SEK-414S SEK-415 SEK-415S SEK-416 SEK-416S SEK-417S SEK-419S
25
ODF
SAE
-1/4" -3/8" -1/4" -3/8" -1/4" -3/8" -1/2" -1/4" -3/8" -1/2" -5/8" 7/8" -3/8" -1/2" -5/8" -3/4" 7/8" 1-1/8" --1/2" -5/8" -3/4" 7/8" 1-1/8"
1/4" -3/8" -1/4" -3/8" -1/4" -3/8" -1/2" -1/4" -3/8" -1/2" -5/8" --3/8" -1/2" -5/8" -3/4" ---3/8" 1/2" -5/8" -3/4" ----
Liquid Flow Capacity (TONS) R22/ R407a/ R134a R407c/ R507 R410a 2
1.5
2
5
3.5
5.5
2
1.5
2
5
4
5.5
2
1.5
2
5.5
4
6
7.5
5.5
8
2
1.5
2
6
4.5
6.5
8.5
6
9
12
8.5
13.5
12
8.5
13.5
6
4.5
6.5
8.5
6
9.5
12.5
9
14
16.5
12
18.5
16.5 17.5 3.59 8.55 8.95 9.95 13 .98 15.35 15.21 16.66 22.75
12 12.5 4.39 10.41 10.85 12.00 17.02 14.03 19 20.35 22.78
18.5 19 4.15 11.32 11.74 13.05 1 8.41 15.04 20.3 22.01 30.25
R134a/ R507
Drying Capacity (lbs) R22/ desiccant R404a R407c/ (cu.in) R410a
15
24
14.5
3
19
28.5
17.5
5
27.5
44
27.5
8
59.5
96
59.5
19
126
204
126
30
263
427
263
65
L(mm) 131 121 139 125 128 118 136 112 152 142 160 146 162 152 164 154 172 158 174 164 186 166 174 239 225 241 231 253 233 235 235 241 245 239 225 241 231 253 241 245 232 235
B(mm)
D(mm)
85
54
82
63
106
63
118
63
185
76
185
89
SDK SOLID CORE LIQUID LINE FILTER DRIER Features
SDK series solid core liquid line tilter drier, using a high-quality compression of small spherical particles sintered desiccant module.combined with high-density filter doth, to dry and the role of filter .that can effectively tilter system residues of water and debris .
Model SDK-052 SDK-052S SDK-053 SDK-053S SDK-082 SDK-082S SDK-083 SDK-083S SDK-084 SDK-084S SDK-162 SDK-162S SDK-163 SDK-163S SDK-164 SDK-164S SDK-165 SDK-165S SDK-167S SDK-303 SDK-303S SDK-304 SDK-304S SDK-305 SDK-305S SDK-306S SDK-307S SDK-309S SDK-413 SDK-414 SDK-414S SDK-415 SDK-415S SDK-417S SDK-419S
Connection ODF
SAE
R134a
-1 /4 -3/8 -1 /4 -3/8 -1 /2 -1 /4 -3/8 -1 /2 -5/8 7/8 -3/8 -1 /2 -5/8 3/4 7/8 1-1/8 --1/2 -5/8 7/8 1-1/8
1/4 -3/8 -1/4 -3/8 -1/2 -1/4 -3/8 -1/2 -5/8 --3/8 -1/2 -5/8 ----3/8 1/2 -5/8 ----
1.72 2.72 2.91 3.62 1.89 2.56 3.33 3.76 5.56 5.88 1.96 2.56 3.19 3.61 5.88 7.1 8.02 8.32 1 2.78 3.61 5.23 6.64 8.78 8.78 10.32 12.12 13.84 16.12 3.58 8.56 8.96 9.96 13.98 16.66 22.75
• Small spherical particles of high strength sintered desiccant module ,to make runtime without shock and friction,reduce wear off the desiccant • High moisture and acid removal capacity • Drying and tittering effect of combining • Filtration:20 microns • With minimum pressure drop design allows the system to play better energy efficiency in the run-time • Two kinds of connection methods: ODF and SAE; In order to tacilitate welding, ODF adoption of TP2 copper reserve • Fora varitey of refrtgerant R-12.R-134a. R-22,R-404A,R-410A.R-S02 • Maximum working pressure: 4.5Mpa
Liquid Flow Capacity (TONS) R12/ R407a/ R12 R407c R410a R507 2.12 2.32 2.22 1.52 3.32 3.62 3.52 2.42 3.53 3.85 3.69 2.54 4.41 4.78 4.68 3.23 2.31 2.28 2.45 1.69 3.12 3.46 3.34 2.23 4.01 4.35 4.36 2.94 4.56 4.88 4.78 3.29 6.75 7.32 7.13 4.96 7.12 7.74 7.56 5.12 2.36 2.57 2.44 1.72 3.12 3.45 3.32 2.19 3.88 4.25 4.11 2.78 4.41 4.79 4.77 3.16 7.14 7.81 7.77 5.23 8.5 9.22 9.01 6.21 9.71 10.45 10.32 7.01 10.12 10.94 10.77 7.32 15 .56 1 6.87 16.54 11.26 4.34 4.71 4.61 3.61 6.36 6.87 6.78 4.63 8.13 8.89 8.64 5.92 10.62 11.52 11.36 7.74 10.69 11.56 11.35 7.74 12.51 13.52 13.33 9.12 14.84 16.06 15.75 10.71 16.84 1823 17.92 12.23 19.63 212 5 20.84 14.21 4.39 4.75 4.65 3.16 10.41 11.32 11.15 7.51 10.85 11.74 11.52 7.84 12.06 13.05 12.84 8.74 17.02 18.41 18.18 12.3 20.35 22.01 21.6 14.78 27.78 30.25 29.41 20.14
R502 1.52 2.31 2.54 3.13 1.58 2.23 2.84 3.19 4.76 5.07 1.63 2.19 2.71 3.13 5.12 6.02 6.82 7.12 10.92 3.11 4.45 5.71 7.53 7.54 8.84 10.44 11.84 13.84 3.09 7.31 7.61 8.54 12 14.35 19.51
L(mm) 123 113 132 116 142 132 150 136 152 142 161 151 170 156 171 161 183 163 172 234 220 236 226 248 228 230 236 240 250 252 242 264 244 252 256
B(mm) D(mm) -77 -77 -96 -96 ---115 -115 -115 -115 115 -180 -180 -180 180 180 180 196 -196 -196 196 196
63
63
76
76
89
www.sanhehvac.com
26
SDCL/SDML LIQUID LINE SOLID CORE DRIER
fig 1
fig 2
fig 3
fig 4
SDML/SDCL series liquid pipeline filter dryer absorbs water, acid and filters solid impurities to protect the refrigeration and air conditioning system. All drying filter core is a molecular sieve sintered filter, the core body of the SDML series is 100% molecular sieve and SDCL series 80% molecular sieve and 20% active aluminum.
Features • Solid filter is a molecular sieve particles stick together, don't move, avoid the powder produced • SDML series and SDCL series have copper over braze welding interface and threaded connections are available • SDML series have good drying and filtering ability, SDCL series with acid absorption and dry filtering capability
• Filtration precision of 25µm, can maintain effective filtering in the minimum pressure drop • Surface coated with corrosion resistant epoxy powder coating, match the requirement of 500 hours salt spray testing • Maximum working pressure of 45 bar • Applicable temperature -40ºC ~ +120ºC
Model Selection Medium type
Refrigerant
Oil
SDCL
SDML
HFC
Usable
Recommended
HCFC
Recommended
Usable
CFC
Recommended
Not applicable
Mineral oil or AB
Recommended
Usable
Pure POE or PAG
Usable
Recommended
Additive POE or PAG
Not applicable
Recommended
For CFC system, it is recommended to use l 038 series dry fillers, in these systems, may need lo use with acid absorption can filter dryer For oil additive in the system, is not recommended to contain active aluminum filter dryer
27
SDCL/SDML LIQUID LINE SOLID CORE DRIER
Specification Model SDML/SDCL-032 SDML/SDCL-032S SDML/SDCL-033 SDML/SDCL-033S SDML/SDCL-052 SDML/SDCL-052S SDML/SDCL-053 SDML/SDCL-053S SDML/SDCL-054 SDML/SDCL-054S SDML/SDCL-082 SDML/SDCL-082S SDML/SDCL-083 SDML/SDCL-083S SDML/SDCL-084 SDML/SDCL-084S SDML/SDCL-085 SDML/SDCL-085S SDML/SDCL-162 SDML/SDCL-l62S SDML/SDCL-l63 SDML/SDCL-l63S SDML/SDCL-l64 SDML/SDCL-l64S SDML/SDCL-165 SDML/SDCL-l65S SDML/SDCL-166 SDML/SDCL-l66S SDML/SDCL-l67S SDML/SDCL-303 SDML/SDCL-303S SDML/SDCL-304 SDML/SDCL-304S SDML/SDCL-305 SDML/SDCL-305S SDML/SDCL-306 SDML/SDCL-306S SDML/SDCL-307S SDML/SDCL-309S SDML/SDCL-413 SDML/SDCL-414 SDML/SDCL-414S SDML/SDCL-415 SDML/SDCL-415S SDML/SDCL-416 SDML/SDCL-416S SDML/SDCL-417S SDML/SDCL-419S
Connections ODF SAE -1/4 1/4 --3/8 3/8 --1/4 1/4 --3/8 3/8 --1/2 1/2 --1/4 1/4 --3/8 3/8 --1/2 1/2 --5/8 5/8 --1/4 1/4 --3/8 3/8 --1/2 1/2 --5/8 5/8 --3/4 3/4 -7/8 --3/8 3/8 --1/2 1/2 --5/8 5/8 --3/4 3/4 -7/8 -1-1/8 --3/8 -1/2 1/2 --5/8 5/8 --3/4 3/4 -7/8 -1-1/8 --
Pressure Drop ∆p = 0.07bar Fluid Refrigerating Capacity (Kw) R134a R404A R507R R22/R410A R407C 6.7 5.1 4.9 7.5 7.1 6.7 5.1 4.9 7.5 7.1 12.9 9.9 9.6 14.5 13.8 12.9 9.9 9.6 14.5 13.8 7.7 5.6 5.5 8.5 8.0 7.7 5.6 5.5 8.5 8.0 12.9 9.8 9.5 14.5 13.8 12.9 9.8 9.5 14.5 13.8 25.7 20.8 20.2 30.2 28.6 25.7 20.8 20.2 30.2 28.6 7.7 5.4 5.3 8.2 7.9 7.7 5.4 5.3 8.2 7.9 14.2 11.0 10.7 16.2 15.3 14.2 11.0 10.7 16.2 15.3 28.6 21.4 20.7 31.7 30.2 28.6 21.4 20.7 31.7 20.2 43.8 35.3 34.3 51.6 48.7 43.8 35.3 34.3 51.6 48.7 7.7 5.4 5.3 8.2 7.9 7.7 5.4 5.3 8.2 7.9 16.3 11.2 10.8 16.8 16.2 16.3 11.2 10.8 16.8 16.2 32.2 23.5 22.7 35.1 33.6 32.2 23.5 22.7 35.1 33.6 44.6 36.6 35.6 53.4 50.2 44.6 36.6 35.6 53.4 50.2 44.5 37.4 36.4 54.4 51.2 44.5 37.4 36.4 54.4 51.2 45.9 40.1 39.2 56.6 52.8 15.7 10.6 10.2 16.6 15.5 15.7 10.6 10.2 16.6 15.5 32.5 25.0 24.3 36.8 35.l 32.5 25.0 24.3 36.8 35.l 43.7 36.9 35.9 53.8 50.9 43.7 36.9 35.9 53.8 50.9 45.7 39.8 38.9 55.6 52.5 45.7 39.8 38.9 55.6 52.5 64.3 54.0 52.5 77.8 73.3 83.6 69.8 67.9 101.6 95.0 18.4 12.4 12.0 19.2 18.2 33.4 26.5 25.7 38.6 36.7 33.4 26.5 25.7 38.6 36.7 55.4 41.8 40.6 62.1 59.l 55.4 41.8 40.6 62.1 59.l 62.4 53.8 52.6 76.6 72.4 62.4 53.8 52.6 76.6 72.4 66.7 56.3 54.8 80.2 76.3 95.3 76.3 74.1 112.3 105.4
Dimensions (mm) A B D L 22.5 111 16.5 99 66 43 27.5 121 19.0 104 22.5 120 18.5 112 27.5 130 75 54 19.0 113 30.0 135 20.0 115 22.5 146 18.5 138 27.5 156 19.0 139 101 54 30.0 161 20.0 141 35.0 171 24.0 149 22.5 155 18.0 146 27.5 165 19.0 148 30.0 170 20.0 110 150 76 35.0 180 24.0 158 40.0 190 26.0 162 28.5 167 27.5 244 19.0 227 30.0 249 20.0 229 35.0 259 189 76 24.0 237 40.0 269 26.0 241 28.5 246 29.0 247 27.5 246 30.0 251 20.0 231 35.0 261 24.0 191 89 239 40.0 271 26.0 243 28.5 248 29.0 249
Type
fig 1
fig 2
fig 3
fig 3
fig 4
fig 4
Remark:1: The capacity to work status: liquid refrigerant temperature tc=30ºC, saturated evaporation temperaturete=-15ºC. the pressure drop ∆p=0.07bar: 2: It is not recommended used when pressure drop ∆P over than 0.14 bar.
www.sanhehvac.com
28
TWO-WAY FILTER DRIER
Features • Internal adopts automatic open and close the reversing device, refrigerant flow and fittration can be carried out in any one party • Installation position is not restricted • Surface coating with corrosion resistant epoxy powder coating, match the requirement of 500 hours salt spray testing • Maximum working pressure is 45bar To pretect the refrigerant in the refrigeration and heating circulation system, it effectively prevent buildup in a direction of pollutants in reversing flow back. Moreover, it saves two external check valve and a oneway filter in the design of unit, which reduces the pipe complexity and the corresponding cost.
Model SFK-082 SFK-082S SFK-083 SFK-083S SFK-084 SFK-084S SFK-085 SFK-085S SFK-162 SFK-162S SFK-163 SFK-163S SFK-164 SFK-164S SFK-165 SFK-165S SFK-166 SFK-166S SFK-167S SFK-303 SFK-303S SFK-304 SFK-304S SFK-305 SFK-305S SFK-306 SFK-306S SFK-307S SFK-309S
Connections ODF -1/4 -3/8 -1/2 -5/8 -1/4 -3/8 -1/2 -5/8 -3/4 7/8 -3/8 -l/2 -5/8 -3/4 7/8 1-1/8
SAE 1/4 -3/8 -1/2 -5/8 -1/4 -3/8 -1/2 -5/8 -3/4 --3/8 -1/2 -5/8 -3/4 ----
Pressure Drop ∆p = 0.07bar Fluid Refrigerating Capacity (Kw) R22 R410C R407C 7.0 7.0 6.9 7.8 7.8 7.4 15.8 15.8 15.4 17.8 17.8 17.4 22.5 22.5 22.1 23.6 23.6 23.2 27.4 27.4 26.6 28.5 28.5 27.8 8.1 8.8 8.4 10.9 12.0 11.6 16.2 16.2 15.8 18.3 18.3 17.9 27.1 27. l 26.7 28.5 28.5 27.8 29.2 29.2 28.5 30.6 30.6 29.9 34.5 34.5 33.6 36.6 36.6 35.9 40.2 40.2 39.6 18.3 18.3 17.9 20.4 20.4 20.0 26.8 26.8 26.4 34.1 34.l 33.4 36.3 36.3 35.5 50.0 50.0 48.9 43.0 43.0 40.2 56.3 56.3 55.3 58.8 58.8 57.7 68.9 68.9 67.8
Dimensions (mm) A 22.5 18.5 27.5 19 30 20 35 24 22.5 18.5 27.5 19 30 20 35 24 40 26 28.5 27.5 19 30 20 35 24 40 26 28.5 29
B 100 100 100 100 100 100 100 100 110 110 110 110 110 110 110 110 110 110 110 181 181 181 181 181 181 181 181 181 181
Remark:1: The capacity to work status: liquid refrigerant temperature tc=30ºC, saturated evaporation temperaturete=-15ºC. the pressure drop ∆p=0.07bar: 2: It is not recommended used when pressure drop ∆P over than 0.14 bar.
29
D 63.5 63.5 63.5 63.5 63.5 63.5 63.5 63.5 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76
L 145 137 155 138 160 140 170 148 155 147 165 148 170 150 180 158 190 162 167 236 219 241 221 251 229 261 233 238 239
SSF SUCTION LINE FILTER DRIER Features • The shortest length has to adapt to the compact installation • Low pressure drop, increase the effective filtration area with pleated filter design • Copper to take over the welded joint • Two repair valves, simplify the pressure drop measurement 5: Filtration precision 40µm • Surface coating with corrosion resistant epoxy powder coating, match the requirement of 500 hours salt spray testing • Maximum working pressure 35bar
SSF series suction line filter features large suction filter core, large shell diameter and internal refrigerant diffusion tube design, to reduce the installation length, provide big filter area and guarantee the maximum efficiency. The divergent tube inside distributes refrigerant evenly to avoid losses and protect the compressor effectively. Model SSF-283T SSF-284T SSF-285T SSF-286T SSF-287T SSF-289T SSF-2811T SSF-2813T
Connection (in) ODF 3/8" 1/2" 5/8" 3/4" 7/8" 1-1/8" 1-3/8" 1-5/8"
Filter Paperarea (in2) 83 83 83 141 141 141 219 219
OIL FILTER
Model SHOF-082 SHOF-082S SHOF-083 SHOF-083S SHOF-084 SHOF-084S SHOF-085 SHOF-085S
Connections ODF SAE -1/4 1/4 --3/8 3/8 --1/2 1/2 --5/8 5/8 --
Dimensions (mm) B D 112 89 112 89 112 89 152 89 152 89 152 89 205 89 205 89
A 19 20 24 26 28.5 29 32 32
L 150 152 160 204 209 210 269 269
Oil filters are of excellent capacity of filtration to insure the limited clean oil (pure POE oil, mineral oil and alkyl benzene oil) into compressor repeatedly. The pure oil could ensure the daily operation of oil level control. as well as reducing the damage of compressor. SHOF series oil filter could provide excellent performance of 3µm partides and sundries and get to 99%, which still have enough flow to remain low pressure drop. Moreover, it can prevent changing oil for compressor that caused by filtered feculence In practical application.
R134a 21.8 27.4 21.8 27.4 21.8 27.4 21.8 27.4
Liquid Flow Capacity (Kw) R22 R404A 23.7 15.7 29.8 19.8 23.7 15.7 29.8 19.8 23.7 15.7 29.8 19.8 23.7 15.7 29.8 19.8
R502 15.4 19.3 15.4 19.3 15.4 19.3 15.4 19.3
A 22.5 18.5 27.5 19 30 20 35 24
Dimensions (mm) B D 96 63.5 96 63.5 96 63.5 96 63.5 96 63.5 96 63.5 96 63.5 96 63.5 www.sanhehvac.com
L 141 133 151 134 156 136 166 144
30
DRY AND SUCTION FILTER CYLINDER
Application • It can match all brands of 48 series filter • Complete specifications, cylinder diameter 114mm, maximum interface size 3-1/8" • For measuring pressure drop and filling with 1/4 NPT access port • Liquid pipe application can choose 48 type drying filter core • The suction on the application can choose 48 type suction filter element
Model SH-485
31
ODF (in) 5/8
pressure drop ∆p(1 2)=0.07bar fluid refrigerating capacity (Kw) R12 R134a R22 R404A/507 R502 52.8 66.9 73.8 49.0 45.8
Size (mm) A 26
B 22
H 149
L 227
SH-487
7/8
97.6
123.2
132.8
88.6
84.8
27
25
150
228
SH-489
1-1/8
140.2
168.6
187.0
124.2
120.0
27
25
150
228
SH-4811
1-3/8
160.2
196.8
214.6
140.2
138.2
32
28
155
232
SH-4813
1-5/8
224.2
274.6
298.0
198.2
194.6
32
28
155
232
SH-4817
2-1/8
253.3
310.2
332.2
235.2
211.2
39
32
161
239
SH-4821G
2-5/8
274.6
335.4
348.6
260.5
232.3
54
50
152
245
SH-4824G
3
302.8
362.6
373.2
288.6
260.5
56
50
145
244
SH-4825G
3-1/8
345.2
386.3
394.4
302.2
278.0
56
50
144
243
SH-967
7/8
109.4
130.4
144.2
96.8
91.2
27
25
295
372
SH-969
1-1/8
165.4
205.6
221.8
148.6
138.6
27
25
295
372
SH-9611
1-3/8
207.6
252.4
278.0
183.0
178.4
32
28
300
377
SH-9613
1-5/8
225.3
276.4
299.2
197.6
192.5
32
28
300
377
SH-9617
2-1/8
257.0
330.8
337.6
288.5
267.4
39
32
306
384
SH-9621G
2-5/8
289.0
356.5
372.1
327.6
295.4
54
50
297
390
SH-9624G
3
323.2
380.4
383.2
360.5
320.4
56
50
290
389
SH-9625G
3-1/8
373.0
394.6
402.6
374.6
368.0
56
50
289
388
SH-1449
1-1/8
197.6
232.8
249.0
281.6
172.5
27
25
437
514
SH-14411
1-3/8
267.5
320.2
344.2
239.4
235.4
32
28
442
519
SH-14413
1-5/8
292.2
348.5
373.6
260.5
257.0
32
28
442
519
SH-14417
2-1/8
330.8
397.3
429.4
295.7
288.6
39
32
448
526
SH-14421G
2-5/8
369.6
394.2
408.3
380.2
345.0
54
50
439
532
SH-14424G
3
402.0
443.2
429.4
415.4
373.2
56
50
432
531
SH-14425G
3-1/8
436.3
454.1
464.5
447.5
380.2
56
50
431
530
SH-19211
1-3/8
285.4
336.8
366.0
253.2
248.6
32
28
592
669
SH-19213
1-5/8
306.2
369.2
397.6
274.5
267.4
32
28
592
669
SH-19217
2-1/8
341.4
408.8
438.2
308.6
296.4
39
32
298
676
SH-19221G
2-5/8
422.4
485.2
521.0
492.8
348.5
54
50
589
682
SH-19224G
3
456.2
507.8
534.6
510.4
406.4
56
50
582
681
SH-19225G
3-1/8
472.2
535.6
562.4
556.2
422.4
56
50
581
680
Filter element quantity
1
2
3
4
DRYING & SUCTION DRIER-FILTER CORE Features Filter cores and unloaded dryer shells produced by SANHE are most popular and replaceable. The filter cores packed with metal cans, having good leak tightness against dirty oil, substances and dust.
• Under special environment, capable of dissoving pollutants such as moisture and acid. • Protecting normal systems as well as clearing up compressors.
D/H Drier-Filter Cores Model
ΦD (mm)
H (mm)
A (mm)
D48
94
140
45
H48
94
140
45
H100
122
166
52
X Suction Line Filter Cores Model
ΦD (mm)
H (mm)
A (mm)
X48
94
140
64
X100
122
166
90
SX Suction Oil Filter Cores Model
ΦD (mm)
H (mm)
A (mm)
SX48
94
140
64
SX100
122
166
90
Mounting Brasket For Demountable Shells Model
ΦD (mm)
H (mm)
L (mm)
A (mm)
M114
114
169
98
10*20
M152
152
207
110
10*20
www.sanhehvac.com
32
SUCTION LINE ACCUMULATOR
In a refrigeration cycle, the refrigerant must be completely vaporized before returning to the compressor. Therefore, the gaseous and liquid refrigerant must be separated before the refrigerant enter the compressor, which will protect the compressor from the liquid hit/ slugging. And the liquid refrigerant will be stored in the accumulator. To make the liquid refrigerant return to the compressor, it will flow through the orifice at the bottom of U shape tube in the accumulator and return to the compressor together with the vapor. With the protection of accumulator, the compressor will have a longer working life and the system can run better.
Features • Prevents liquid slugging, controlled liquid return • Designed maximum flow and minimal pressure drop • Use with HFFC and HFC refrigerant and with associated oils • Stamped "Inter" position • Designed "U" shape for return tube • High corrosion-resistant paint coating finish • The max.working pressure 3.1 MPa,the burst pressure 19MPa, the Medium temperature: -40ºC ~ 120ºC
Technical parameters Conn. Size (inch)
ΦD
SH-384
1/2"
75
150
25
40
SH-595
5/8”
127
216
35
SH-596
3/4”
127
216
SH-5126
3/4”
127
SH-5127
7/8”
SH-5137
Model No.
33
H H1 A (mm) (mm) (mm)
Nominal Capacity(Kw) at the following evaporating temperature ºC R22
R134a
R404A
volume(L)
schematic drawing
-18ºC
5ºC
-18ºC
5ºC
-18ºC
5ºC
70
5.1
11.8
2.7
7.1
4.5
7.2
2.5
a
35
70
6.3
14.1
3.2
8.1
5.3
9.2
2.5
a
298
35
70
6.3
14.1
3.2
8.1
5.3
9.2
3.3
a
127
298
37
70
11.6
25.7
6.3
14.0
9.5
16.2
3.3
a
7/8”
127
323
37
70
11.6
25.7
6.3
14.0
9.5
16.2
3.6
a
SH-5139
1-1/8”
127
323
45
70
18.9
41.5
10.9
25.3
15.5
26.7
3.6
a
SH-5179
1-1/8”
127
426
45
70
18.9
41.5
10.9
25.3
15.5
26.7
5
a
SH-51711
1-3/8”
127
426
50
70
29.9
66.1
16.2
37.6
25.3
42.9
5
a
SH-61411
1-3/8”
159
348
50
70
29.9
66.1
16.2
37.6
25.3
42.9
6.5
a
SH-62013
1-5/8’’
159
515
55
70
45.0
101.3
25.7
59.8
37.6
64.0
9.5
a
SUCTION LINE ACCUMULATOR
In a refrigeration cycle, the refrigerant must be completely vaporized before returning to the compressor. Therefore, the gaseous and liquid refrigerant must be separated before the refrigerant enter the compressor, which will protect the compressor from the liquid hit/ slugging. And the liquid refrigerant will be stored in the accumulator. To make the liquid refrigerant return to the compressor, it will flow through the orifice at the bottom of U shape tube in the accumulator and return to the compressor together with the vapor. With the protection of accumulator, the compressor will have a longer working life and the system can run better.
Features • Prevents liquid slugging, controlled liquid return • Designed maximum flow and minimal pressure drop • Use with HFFC and HFC refrigerant and with associated oils • Stamped "Inter" position • Designed "U" shape for return tube • High corrosion-resistant paint coating finish • The max.working pressure 3.1 MPa,the burst pressure 19MPa,the Medium temperature -40ºC ~ 120ºC
Technical parameters Nominal Capacity(Kw) at the following evaporating temperature ºC H H1 A volume(L) R22 R134a R404A (mm) (mm) (mm) -18ºC 5ºC -18ºC 5ºC -18ºC 5ºC
Model No.
Conn. Size (inch)
ΦD
SH-204
1/2”
102
224
30
53
3.2
7.0
2.17
4.3
2.8
4.6
1.6
a
SH-205
5/8”
102
264
30
53
4.9
10.5
2.8
6.0
4.2
7.0
1.9
a
SH-206
3/4”
140
276
36
80
6.3
14.1
3.2
8.1
5.3
9.2
3.8
a
SH-207
7/8”
140
326
36
80
11.6
25.7
6.3
14.0
9.5
16.2
4.4
a
SH-208
1-1/8”
165
413
40
82
18.9
41.5
10.9
25.3
15.5
26.7
8
a
SH-209
1-3/8”
165
533
40
82
29.9
66.1
16.2
37.6
25.3
42.9
10.5
a
SH-210
1-5/8’’
165
583
40
82
45.0
101.3
25.7
59.8
37.6
64.0
11.5
a
SH-221
2-1/8”
219
750
50
120
-
-
-
-
-
-
24
b
SH-1817
2-1/8”
219
490
50
120
-
-
-
-
-
-
18
b
schematic drawing
www.sanhehvac.com
34
HEAT EXCHANGER ACCUMULATOR SH heat exchanger suction acumulator has strong construction. It can prevent the lose of refrigerating capacity well.In the cooling system,it is separated high pressure and low pressure about the refrigerant flowing pipeline. The refrigerant which is higher temperature in the high pressure pipeline would be cooled via the condenser, but the regrigerant which is lower temperature via the evaporator would be separated gas and liquid in the suction line accumulator. the liquid refrigerant would be evaporated into full gaseity by the heat and enter into the compressor. it prevent slugging the compressor by liguid refrigerant, so that the lifetime of the compressor is longer.
Features • The firm steel shells for long Iife • High resistant corrosion pant power coating finish • Max.working pressure:2.8MPa,the burst pressure 17.5MPa • It is suitable with HFC, HCFC, CFC refrigerant and with associated oil • It is strongly commended to instalI the heat exchanger accumulator when the evapour temperature is lower than -15ºC in the refrigeration system
Technical Parameters Model No.
35
Suction line Liquid State tube(inch) tube(inch)
ΦD(mm)
H(mm)
H1(mm)
A(mm)
B(mm)
Volume(L)
Schematic Drawing
SH-2404
1/2"
3/8"
102
224
30
53
53
1.6
a
SH-2405
5/8"
3/8"
102
264
30
53
53
1.9
a
SH-2406
3/4"
1/2"
140
276
36
80
80
3.8
a
SH-2407
7/8"
1/2"
140
326
36
80
80
4.4
a
SH-2411
1-1/8''
5/8"
165
413
40
82
82
8
a
SH-2413
1-3/8"
3/4"
165
533
40
82
82
10.5
a
SH-2415
1-5/8''
7/8"
165
583
40
82
82
11.5
a
SH-2421
2-1/8"
7/8"
219
490
50
120
120
18
b
CONVENTIONAL OIL SEPARATOR
It is intended for low pressure oil control system and compatible to HFC and HCFC refrigerants(R134a,R404A, R507,R407A,R407C,R22etc ). It's designed for use with scroll and reciprocating type compressor, but not recommended for crew or rotary vane compressors.
Features • • • • • •
Medium Temperature: -40 ~ +120° C Max.working pressure: 3.1MPa Burst pressure: 19MPa Oil storage volume: 55813→559011-- 600ml, 569011→569417-- 1000ml The thickness of paint film thickness: 50→80um
Technical Parameters Nominal capacity(Kw) at the following evaporating temperature ºC R22 R143a R404A/R507 -40ºC -20ºC 5ºC -40ºC -20ºC 5ºC -40ºC -20ºC 5ºC
Connection Size (inch)
ΦD
SH-55813
3/8"
102
242
35
48
4.8
5.9
6.4
2.9
4.0
5.6
4.8
5.7
6.3
SH-55824
1/2"
102
242
35
48
5.3
6.2
7.0
3.2
4.5
6.2
5.3
6.2
7.0
SH-55855
5/8"
102
336
37
48
15.8
17.5
19.3
11.4
13.4
15.8
14.4
16.4
19.3
SH-55866
3/4"
102
336
37
48
24.6
26.2
28.1
16.7
19.3
22.4
22.8
25.2
28.8
SH-55877
7/8"
102
418
39
48
24.6
26.2
28.1
16.7
19.3
22.4
22.8
25.2
28.8
SH-55888
1"
102
448
45
48
31.7
34.3
37.0
22.4
26.3
29.9
30.0
33.4
37.4
SH-55889
1-1/8"
102
448
45
48
31.7
34.3
37.0
22.4
26.3
29.9
30.0
33.4
37.4
SH-559011
1-3/8"
102
473
45
48
40.4
43.6
47.5
28.1
33.6
40.4
36.7
43.3
49.0
SH-569011
1-3/8"
159
350
43
70
45.2
47.4
49.2
33.4
40.4
48.4
41.0
45.2
50.8
SH-569213
1-5/8"
159
428
48
70
56.3
58.9
63.3
41.3
48.4
56.3
51.0
57.3
65.1
SH-569417
2-1/8"
159
490
52
70
91.4
102.3
105.5
63.3
74.8
88.8
88.5
98.4
108.6
Model
Dimensions(mm) H(mm) H1(mm) A(mm)
www.sanhehvac.com
36
DEMOUNTABLE (FLANGE) OIL SEPARATOR
It is intended for low pressure oil control system and compatible to HFC and HCFC refrigerants(R134a,R404A, R507,R407A,R407C,R22etc ). It's designed for use with scroll and reciprocating type compressor, but not recommended for crew or rotary vane compressors.
Features • Medium Temperature: -40 ~ +120° C • Max.working pressure: 3.1MPa • Burst pressure: 19MPa • Oil storage volume: 5300→5305 600ml, 6303→6305 1000ml • The thickness of paint film thickness: 50→80um
Technical Parameters
37
Nominal capacity(Kw) at the following evaporating temperature ºC R22 R143a R404A/R507 H(mm) H1(mm) A(mm) -40ºC -20ºC 5ºC -40ºC -20ºC 5ºC -40ºC -20ºC 5ºC
Connection Size (inch)
ΦD
SH-5300
3/8"
102
247
30
48
4.8
5.9
6.4
2.9
4.0
5.6
4.8
5.7
6.3
SH-5301
1/2"
102
247
30
48
5.3
6.2
7.0
3.2
4.5
6.2
5.3
6.2
7.0
SH-5302
5/8"
102
341
32
48
15.8
17.5
19.3
11.4
13.4
15.8
14.4
16.4
19.3
SH-5302A
3/4"
102
341
32
48
24.6
26.2
28.1
16.7
19.3
22.4
22.8
25.2
28.8
SH-5303
7/8"
102
423
34
48
24.6
26.2
28.1
16.7
19.3
22.4
22.8
25.2
28.8
SH-5303A
1"
102
453
40
48
31.7
34.3
37.0
22.4
26.3
29.9
30.0
33.4
37.4
SH-5304
1-1/8"
102
453
40
48
31.7
34.3
37.0
22.4
26.3
29.9
30.0
33.4
37.4
SH-5305
1-3/8"
102
478
40
48
40.4
43.6
47.5
28.1
33.6
40.4
36.7
43.3
49.0
SH-6303
1-3/8"
152
355
38
70
45.2
47.4
49.2
33.4
40.4
48.4
41.0
45.2
50.8
SH-6304
1-5/8"
152
433
43
70
56.3
58.9
63.3
41.3
48.4
56.3
51.0
57.3
65.1
SH-6305
2-1/8"
152
495
47
70
91.4
102.3
105.5
63.3
74.8
88.8
88.5
98.4
108.6
Model
Dimensions(mm)
MECHANICAL OIL LEVEL REGULATOR
Mechanical oil level regulator is to control oiI level in the compressor crankcase to protect the compressor. Mechanical oil level regulators are used in low pressure oiI management system.They are designed for use with reciprocating compressors, but not recommended for scroll compressors.
Features • Proven needle valve design • Stainless steeI float ball • Special mounting flange allows direct fitting to standard compressors • VisuaI indication of oil level via large sight glass • Allowable working pressure: 0 MPa ~ 3.1MPa • Allowable working temperature: 0ºC~ 100ºC
How it works Oil fed to oil level regulator by inlet connection, an internal needle valve either allows or shuts off an oil supply to the regulator. An internal ball float controls the position of the needle valve. During the compressor operation, the crankcase oil level reduces and a reduction in oil level activates the regulator, which ensures the correct crankcase oil Ievel is achieved and maintained. Adjuslable mechanical oil level regulator has in- built mechanism that allows the ball float to be adjustable: up or down. Some regulator models are fitted with an equalization connection which enable the oil levels between several compressors to be balanced.
Technical parameters Model SHOLC-A1 SHOLC-A2
ΦD (mm) 102 102
H (mm) 115 115
H1 (mm) 60 60
A (mm) 101 101
Sight Glass QTY 1 2
Model SHOLC
ΦD (mm) 102
H (mm) 115
H1 (mm) 55
A (mm) 100
B (mm) 100 www.sanhehvac.com
38
VERTICAL LIQUID RECEIVER
Liquid receivers are used in refrigeration systems for the purpose of allowing the system to adjust to varying loads. They should be able to store liquid refrigerant for evaporators, which ensures only liquid refrigerant enters the liquid line and stores all of the liquid refrigerants in the system when the system maintain.
Features • With the PTFE sealing gasket. • High corrosion-resistant powder coating finish, it can be use in aII environments, including marine applications • Refrigerant: HFC, HCFC, CFC, as well as with their associated oil. • Max. allowance working pressure: 4.2MPa, burst pressure: 19MPa • Allowance working temperature: -40°C ~ 100°C: • Can design and customize special receivers as customer's requirement.
Specification
39
Model
ODF Conn.(in)
ΦD (mm)
H (mm)
H1 (mm)
H2 (mm)
A (mm)
volume (L)
SH-01
3/8"
89
194
132
40
40
1.1
SH-02
3/8"
127
258
181
40
40
2.8
SH-03
3/8"
127
289
204
40
40
3.9
SH-04
1/2"
159
348
277
40
40
6.3
SH-05
5/8"
165
414
320
45
45
8
SH-06
3/8"
165
560
510
45
45
12
SH-07
7/8"
165
700
610
45
45
14
VERTICAL LIQUID RECEIVER
Liquid receivers are used in refrigeration systems for the purpose of allowing the system to adjust to varying loads. They should be able to store liquid refrigerant for evaporators, which ensures only liquid refrigerant enters the liquid line and stores all of the liquid refrigerants in the system when the system maintain.
Features • With the PTFE sealing gasket. • High corrosion-resistant powder coating finish, it can be use in aII environments, including marine applications • Refrigerant: HFC, HCFC, CFC, as well as with their associated oil. • Max. allowance working pressure: 4.2MPa, burst pressure: 19MPa • Allowance working temperature: -40°C ~ 100°C: • Can design and customize special receivers as customer's requirement.
Specification Model
ODF Conn.(in)
ΦD(mm)
H(mm)
H1(mm)
A(mm)
volume(L)
schematic drawing
SH-133
3 /8"
102
180
40
45
1
a
SH-233
3/8"
127
195
40
50
2
a
SH-333
3/8"
127
310
40
50
3
a
SH-433
3/8"
165
245
40
55
4
a
SH-644
1/2"
165
330
40
55
6
a
SH-844
1/2"
165
415
40
55
8
a
SH-1055
5/8"
219
310
45
75
10
b
SH-1255
5/8"
219
370
45
75
12
b
SH-1455
5/8"
219
430
45
75
14
b
SH-1677
7/8"
219
489
50
75
16
b
SH-1877
7/8"
219
549
50
75
18
b
SH-2177
7/8"
219
610
50
75
21
b
www.sanhehvac.com
40
VERTICAL LIQUID RECEIVER 1. SANHE according to the specific needs of customers design and manufacture of special liquid receiver 2. Design for during normal operation and system maintenance storage refrigerants 3. Allows the system to adjust to adapt to the different conditions and load system 4. Structure design for vertical and horizontal optional 5. Available for selection: depending on the liquid mirror, cut-off valve, mounting bracket, the welding joint, threaded connection, the relief valve connection mouth mouth, fusible plug, etc 6. Surface coated with corrosion resistant epoxy powder coating
Features • Adopt the manufacture drawing structure design • The fluid end equipped with cut-off valve, fluid end can match threaded connectors or welding • Vertical accumulator in order to achieve the best operation, should be installed vertically • Maximum working pressure 35 bar
Specification
41
Overall dimensions(mm)
Model
Inlet A (in)
Outlet B (in)
D
h
H
d
SH-03-1L
3/8
3/8
91
40
230
63.5
1.0L
SH-03-2.1L
3/8
3/8
120
40
260
76
2.1L
SH-04-3.2L
1/2
1/2
150
40
260
76
3.2L
SH-43-3.2L
1/2
3/8
150
40
260
76
3.2L
SH-04-4L
1/2
1/2
150
40
320
76
4.0L
SH-43-4L
1/2
3/8
150
40
320
76
4.0L
SH-04-5.5L
1/2
1/2
180
40
290
76
5.5L
SH-04-6.2L
1/2
1/2
180
40
318
76
6.2L
SH-04-7L
1/2
1/2
180
40
350
76
7.0L
SH-54-7L
5/8
1/2
180
40
350
76
7.0L
SH-05-7L
5/8
5/8
180
40
350
76
7.0L
SH-05-10L
5/8
5/8
220
40
350
89
10.0L
SH-05-12L
5/8
5/8
220
40
400
89
12.0L
SH-65-12L
3/4
5/8
220
40
400
89
12.0L
SH-65-14L
3/4
5/8
220
40
450
89
14.0L
SH-07-14L
7/8
7/8
220
45
455
89
14.0L
SH-09-14L
1-1/8
1-1/8
220
53
463
89
14.0L
Cubage
VERTICAL LIQUID RECEIVER 1. SANHE according to the specific needs of customers design and manufacture of special liquid receiver 2. Design for during normal operation and system maintenance storage refrigerants 3. Allows the system to adjust to adapt to the different conditions and load system 4. Structure design for vertical and horizontal optional 5. Available for selection: depending on the liquid mirror, cut-off valve, mounting bracket, the welding joint, threaded connection, the relief valve connection mouth mouth, fusible plug, etc 6. Surface coated with corrosion resistant epoxy powder coating
Features • Adopt the manufacture drawing structure design • The fluid end equipped with cut-off valve, fluid end can match threaded connectors or welding • Vertical accumulator in order to achieve the best operation, should be installed vertically • Maximum working pressure 35 bar
Specification Inlet A
Outlet B
(in)
(in)
D
E
F
H
Φd
SH-101
3/8"
1/4"
91
145
145
230
63 . 5
1.2 L
SH-102
3/8"
3/8"
127
170
170
255
76
2.8 L
SH-103
3/8"
3/8"
127
228
228
317
76
3.5 L
SH-104
1/2"
1/2"
156
285
285
372
76
6.3 L
SH-105
5/8"
5/8"
180
332
285
422
89
9.6 L
Model
Dimensions (mm)
Cubage
www.sanhehvac.com
42
HORIZONTAL LIQUID RECEIVER Features • Adopt the steel structure design • In/out liquid interface can be customized according to customer's requirements • There is no limit on the cut-off valve installation Angle, depending on the liquid lens is optional • Horizontal accumulator in order to achieve the best operation, should be installed • Surface coated with corrosion resistant epoxy powder coating • Maximum working pressure 35 bar
Model SH-07B-20.8L SH-07B-30.2L SH-07B-39.3L
Inlet A (in) 1-1/4-12UUNF 1-1/4-12UUNF 1-1/4-12UUNF
Outlet B (in) 7/8 7/8 7/8
ΦD 219 219 219
E 159 116 116
F 390 713 983
Dimensions (mm) M N I 132 400 111 172 600 214 237 740 349
J 381 381 381
H 549 829 1099
L 664 944 1214
Cubage 20.8 L 30.2 L 39.3 L
Features • Adopt the steel structure design • In/out liquid interface can be customized according to customer's requirements • There is no limit on the cut-off valve installation Angle, depending on the liquid lens is optional • Horizontal accumulator in order to achieve the best operation, should be installed • Surface coated with corrosion resistant epoxy powder coating • Maximum working pressure 35 bar
Technical parameters Model SH-07-12L SH-05-14.3L SH-07-14.3L SH-07A-18L SH-05A-23.1L SH-07A-26.7L SH-07A-30L SH-07A-33.4L SH-09A-33.4L SH-07A-40L SH-09A-40L SH-07A-45L SH-09A-45L SH-11A-45L SH-09A-50.4L SH-11A-50.4L SH-09A-54.7L SH-11A-54.7L
43
Inlet A (in) 7/8" 5/8" 7/8" 7/8" 5/8" 7/8" 7/8" 7/8" 1-1/8" 7/8" 1-1/8" 7/8" 1-1/8" 1-3/8" 1-1/8" 1-3/8" 1-1/8" 1-3/8"
Outlet B (in) 7/8" 5/8" 7/8" 7/8" 5/8" 7/8" 7/8" 7/8" 1-1/8" 7/8" 1-1/8" 7/8" 1-1/8" 1-3/8" 1-1/8" 1-3/8" 1-1/8" 1-3/8"
ΦD 159 159 159 159 219 219 219 219 219 273 273 273 273 273 273 273 273 273
E 110 110 110 120 140 150 150 150 150 160 160 160 160 160 160 160 160 160
F 450 580 580 760 420 500 600 700 700 480 480 580 580 580 680 680 780 780
Dimensions (mm) M N I 110 450 120 140 520 120 140 520 220 175 760 220 120 460 220 135 530 220 175 550 220 175 650 220 175 650 220 150 500 220 150 500 220 150 600 220 150 600 220 150 600 220 175 650 220 175 650 220 200 700 220 200 700 220
J 165 165 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270 270
H 110 110 110 110 139.5 139.5 139.5 139.5 139.5 166.5 166.5 166.5 166.5 166.5 166.5 166.5 166.5 166.5
L 670 800 800 1000 700 800 900 1000 1000 800 800 900 900 900 1000 1000 1100 1100
Cubage 12.0 L 14.3 L 14.3 L 18.0 L 23.1 L 26.7 L 30.0 L 33.4 L 33.4 L 40.0 L 40.0 L 45.0 L 45.0 L 45.0 L 50.4 L 50.4 L 54.7 L 54.7 L
OIL RECEIVER The oil receiver is the container of spare oil which has sight glass ports to observe the oil level in the device. The valve on the top of it gets oil from oil separator. The valve on the bottom of it can distribute the oil to oil regulator.There is a 1/4 inch threaded connection on the side of valve to increase or decrease spare oil.High pressure gas returns with the oil from the oil separator to it. The pressure would cause negative effects to oil controller.To prevent this phenomenon,a vent line is installed from the top of the oil receiver to suction line. This line permits the pressure in the oil receiver to be approximately same as suction line and compressor crankcase
Features • • • •
Multiple models for choices Sight glass with floating ball Seal ring is made of PTFE gasket Standard models suppliped with U type mounting brackets to install conveniently • The surface is corrosion resistant epoxy powder coating • Maximum working pressure: 35 Bar
Connection Size Model
Dimensions (mm)
Cubage (L)
(In/Out) ODF
SAE
ΦD
A
B
h
H
Cubage I
Cubage II
Gross Capacity
SHOC-633
3/8"
1/4NPT
159
97
150
344
426
1.6 L
4.4 L
6.0 L
SHOC-833
3/8"
1/4NPT
159
110
220
440
522
1.9 L
5.9 L
7.8 L
SHOC-1033
3/8"
1/4NPT
159
132
285
549
631
2.3 L
7.5 L
9.8 L
SHOC-1233
3/8"
1/4NPT
159
140
360
640
722
2.4 L
9.1 L
11.5L
SHOC-1433
1/2"
1/4NPT
159
194
350
739
821
3.4 L
9.8 L
13.2 L
SHOC-1955
1/2"
1/4NPT
219
140
300
580
662
4.3 L
14.7 L
19.0 L
SHOC-2355
5/8"
1/4NPT
219
140
420
700
782
4.2 L
18.9 L
23.1 L
www.sanhehvac.com
44
SHELL & TUBE HEAT EXCHANGER
Features • High efficiency, coefficient up to 10000W/m2C. Heat exchanging capacity 3-7 times traditional equipments. • Compact configure, occupy small area, one tenth as the traditional equipments • Stainless steel and/or titanium material, endure high temperature, pressure and corruption. • Helix screw thread elasticity heat exchange bundle, eliminate the stress. • Design flux speed is 5.5m/s, less dirt. • ASME standard VIII-1. • Big flow volume. • Easy installation and durable.
Model
A (mm)
B (mm)
C
E
SH-55K SH-85K SH-155K SH-210K SH-300K SH-360K SH-600K SH-1200K SH-2400K SH-3000K SH-3600K SH-4500K SH-5000K SH-6000K
60 60 76 76 76 89 114 133 168 168 168 219 219 219
360 520 450 570 780 830 900 900 950 1100 1300 1070 1120 1220
3/4" 3/4" 1" 1-1/2" 1-1/2" 1-1/2" 2" 2" 2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2"
1" 1" 1-1/2" 1-1/2" 2" 2" 2-1/2" 2-1/2" 4" 4" 4" 4" 4" 4"
Model SH-55K SH-85K SH-155K SH-210K SH-300K SH-360K SH-600K SH-1200K SH-2400K SH-3000K SH-3600K SH-4500K SH-5000K SH-6000K
45
kW 16 25 45 61 88 105 175 352 704 880 1056 1320 1467 1760
Normal Capacity Kbtu/hr 55 85 155 210 300 360 600 1200 2400 3000 3600 4500 5000 6000
Pool Capacity Gallons @ 1° F/hr Liters @ 1°C/hr 4700 32021 7300 49735 13300 90613 18000 122634 25800 175776 31500 214610 52500 357684 105600 719455 211200 1438910 264000 1798638 316800 2158365 396000 2697956 439000 3000000 526800 3600000
Heat Transfer Area m2 0.15 0.25 0.33 0.44 0.64 0.85 1.55 2.01 4.47 5.30 6.42 8.46 8.87 10.64
NOTE
www.sanhehvac.com
46
NINGBO SANHE REFRIGERATION CO., LTD 1105, 535th, Tiantong South Road, Yinzhou District, Ningbo, Zhejiang, China 315100
Telephone: 0086-574-82833733
Fax: 0086-574-88226612
Email: sales@sanhehvac.com