DAISY™: Door Alarm Indication System Proven Behavioral Healthcare Solutions Supporting a secure, comfortable, healing environment
Securitech’s Door Alarm Indication System is designed to alert nursing staff to a patient-harm situation, while blending in to the room to promote a calm environment Thousands of patients are protected by the DAISY™ system technology each and every day. Applications: Behavioral Healthcare Wards Intake Rooms VA Medical Centers
DAISY™ Multi-Door Door Alarm Indication System
Protecting Patients:
Swinging doors present an opportunity for patients to harm themselves. Securitech created alarm sensors for doors which notify staff when there is an attempt to cause harm at the door. The aesthetic, curved design resembles applied molding and supports the concept that visible hardware should support the serene environment. Related consoles, key switches, strobes, and other peripheral items enable the creation of complete notification systems. While there is no replacement for continuous observation, Securitech’s DAISY™ is a useful tool to aid the nursing staff. The attractive rounded sensor bar at the top of the door pivots when pressure is applied and sends a signal to a strobe above the door in the corridor and to the nurse station console. DAISY™ alarms can only be reset by visiting a door after notification of an incident, assuring a physical response. DAISY™ console is a simple notification system, with no training , software or computer system required.
Design Flexibility
Customizable to meet your needs. Considerations include: • Corridor or in-room bathroom door • Door swing • Sensors on pull or both sides of door • Single direction swinging door or double acting • Desk or wall mounted console • Multiple console locations
Simplicity of Design
Aesthetically Designed To Detect Items Draped On Door
• Curved bar design and multiple sensors detect pressure placed on door • Neutral beige color blends in with environment • Durable construction, mounts securely to the door
Life-Safety System Design • Staff member must visit emergency door in order to shut off alarm
Signaling Options
• Designed to be easily integrated into the layout of any facility • Provides alarm signals to console and strobe • Nuisance alarm (tapping does not trigger alarm: field programmable) • Optional remote signal output
DAISY™ has been designed without software or programming. There’s no computer, monitor, annual maintenance agreements, upgrades or complicated nurse training.
Certifications
Fire Door Applications • Approved to be used as a component in a Fire Door assembly with up to 3-hour rating with hose stream
Strobe Light
Desk Console
DAISY™ Sensor Bar
Ligature-Resistant Transfer Hinge Wall Mounted Console
FS1 (left), DALAH (right) Key Reset Switch DAISY™ bar and full length hinge with exclusive frame header segment
Splice Box
Sample System Layout
How to build your DAISY system: • DAISY™ Bar; one per door • DAISY™ Hinge; one per door • DALAH™ Hinge; Used on double acting doors. • Reset Key Switch; located outside each room • Strobe Light; located outside each room • Power Supply and Controller (12/24/36 door system) • Nurse Station Console; Desk or Wall Mounted (12/24/36 door system) • Additional Console or Output; Optional, to meet facility requirements • Inner door option; Splice box integrates one bathroom + bedroom door on nurse console; shared reset keyswitch and strobe; reduces wire runs required to room Controller • DAISY™ is a hardwired run Console 110vACsystem, requiring a direct from the controller to each room.
Controller
Console
110vAC
Low Voltage Circuits 1
2
3
4
5
Door Sensor Assembly & Hinge Power Transfer
3
4
Sample Wire Run
5
6
7
8
9
10
11
12
110vAC
One per door
Keyswitch
One per door or room
Strobe Light
One per door or room
From
110vAC
To
Controller
-Power for console & LEDs -Input for Door Sensor Assemblies and Keyswitches -Outputs for strobe, siren and dry contact -Specify 12, 24, 36 or 48 door capacity -Adjustable “Nuisance alarm” timer -Includes piezo siren, status LED for each door, silence button -Adjustable piezo volume dial within console (not visible)
#
Size
One per door or room
Keyswitch
To
-Power for console & LEDs -Input for Door Sensor Assemblies and Keyswitches -Outputs for strobe, siren and dry contact -Specify 12, 24, 36 or 48 door capacity -Adjustable “Nuisance alarm” timer -Includes piezo siren, status LED for each door, silence button -Adjustable piezo volume dial within console (not visible)
#
Size
Application
Power
Controller Console 3 18 AWG Power & Alarm Controller Console 12 22 AWG LEDs Controller Console 2 22 AWG Silence Button
Application
Please Note: Wire gauge may change when longer distances are involved
Controller Door 1 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 2 6 18 AWG Sensor, Strobe, Keyswitch Controller Controller Door 3 6 18 AWG Sensor, Strobe, Keyswitch Console 110vAC Controller Door 4 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 5 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 6 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 7 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 8 6 18 AWG Sensor, Strobe, Keyswitch Low Voltage Circuits Controller Door 9 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 10 6 18 AWG Sensor, Strobe, Keyswitch 1 2 3 4 5 6 7 8 9 Controller Door 11 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 12 6 18 AWG Sensor, Strobe, Keyswitch
Please Note: Wire gauge may change when longer distances are involved
One per door
Strobe Light
Controller
Power
Controller Console 3 18 AWG Power & Alarm Controller Console 12 22 AWG LEDs Individual Door Elements Controller Console 2 22 AWG Silence Button Door Sensor Assembly & Hinge Power Transfer
11
Controller Door 1 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 2 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 3 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 4 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 5 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 6 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 7 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 8 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 9 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 10 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 11 6 18 AWG Sensor, Strobe, Keyswitch Controller Door 12 6 18 AWG Sensor, Strobe, Keyswitch
Individual Door Elements
Console
10
One per door or room
Console
From
Controller/Power Supply
9
Individual Door Elements
Individual Door Elements Door Sensor Assembly & Hinge Power Transfer
8
Keyswitch
Controller/Power Supply
2
7
Individual Door Elements
Low Voltage Circuits 1
6
10
11
One per door One per door or room
12
12
ELEMENTS Door Sensor Assemblies
ELEMENTS
Doo
DSY-DSA-P1-__ DSY-DSA-P2-__ DSY-DSA-P6-__ DSY-DSA-P5-__ DSY-DSA-P0-__
36" to 42" door width 42" to 48" door width 29" to 35" door width 35" to 41" door width Less than 28"door width; consult factory
DSY-FS1-6-2W
Flat profile 2-wire anti-lig sensor. 6-1/8" x 2" x 3/8". Used when door may impact frame in center hung or deep reveal applications. FS1 projects only 3/8" from the door's face and has an integral stainless steel impact bumper to protect the FS1 and door. FS1 can be used with DALAH double acting hinge sensors or electrified pivots by others.
Con
Exposed door width must be measured when a sensor bar is also applied to the push side of the door
Controller DSY-1A52-12
Controller/Power Supply for a 12 room DAISY including: Door sensor (DSA) inputs Reset keyswitch inputs Strobe output Console output Remote signal output Remote siren output Adjustable "Nuisance" delay (factory pre-set: 3sec) Note: Requires 110v input
DSY-1A52-24 DSY-1A52-36
Con
Same as above, for up to 24 rooms Same as above, for up to 36 rooms
Contact Factory For Custom Configurations
Con
Controller Modifications DSY-CPS-MOD-2
2nd console output (for 2nd nurse or guard station)
Console DSY-DCRS-12
Desk mounted console for 12 room DAISY including:
DSY-DCRS-24 DSY-DCRS-36 DSY-WCRS-12 DSY-WCRS-24 DSY-WCRS-36
Same as above, for up to 24 rooms Same as above, for up to 36 rooms Wall-mounted console for 12 room DAISY Wall-mounted console for 12 room DAISY Wall-mounted console for 12 room DAISY
Wall mounted units require recessing within drywall; all other elements identical to DCRS-12
Keyswitch DSY-KS101
Wall mounted keyswitch (single gang box by others) Mortise cylinder required (by others)
Strobe Light DSY-SL1 DSY-SL2
Strobe light for ceiling mounting (use with ceiling tiles) Same as above with steel mounting plate
Ligature‐Resistant Transfer Hinge DSY-ECHFS-MH-AL-4-(handing) (height - 84" standard)
Full-surface angled aluminum hinge modified for use with DAISY Handing and size required when ordering
DSY-DALAH-8-2W
Double acting upper 8" tall hinge element contains dual anti-lig sensors and a 2-wire signal transfer for use with FS1 and all Daisy Sensor Bars. Order with the lower A508 hinge element, sold separately.
DSY-DALAH-A508-HT
c:\mb x1 files\xi docs\technical\seda\DAISY Elements v1.vsd\page-1\as of5/2/17
LED (1 Green/Red per room) Momentary piezo silence button Piezo volume adjustment (within console)
Keys
Stro
Elec
Acce
Double acting DALAH hinge made in u.s.a.shown by SECURITECH GROUP, INC. 54‐60 need with FS1
Full length stainless steel pin-in-barrel double acting hinge element for use with DALAH upper sensor section. To order, specify full height of opening, less 8-1/8" for DALAH. Contact factory for ordering requirements.
Contact factory for different finish or use with electrified locks
Accessories DSY-SPLB-1
Splice box for use within room containing multiple doors Up to 5 doors… splice within room to reduce wire run
DSY-DSA
Manufactured in the USA
2nd door sensor where additional door monitoring is advisable
54-60 46th St. Maspeth, NY 11378
FS1 used with center hung pivot and DAISY sensor
718.392.9000