50 Hz Water-Source Heat Pumps


tranquility large (tlV) Series

The award winning Tranquility Large (TLV) Series raises the bar for water-source heat pump efficiencies, features and application flexibility. Not only does the Tranquility Large Series exceed ASHRAE 90.1 efficiencies, but it also uses EarthPure® (HFC-410A) zero ozone depletion refrigerant, making it an extremely environmentally-friendly option. Tranquility Large Series is eligible for additional LEED® (Leadership in Energy and Environmental Design) points because of the “green” technology design.

Condensate overflow is one of the 8 standard safeties provided by the microprocessor controls in all TLV Series units

Belt drive blowers with high efficiency motors and multiple pulley adjustments Wide variety of vertical configurations Large capacity up to 87.97 kW Galvanized steel cabinet with baked-on epoxy powder finish on all access panels

Dual compressor refrigeration circuit in TLV 168-300 equipment single compressor refrigeration circuit in TLV 084-150 Optional insulated water/ refrigerant circuits allow extended range operation (ground loop applications)


tranquility large (tlV) Series

Unit Features • Vertical sizes 084 (24.6 kW) through 300 (87.9 kW)

• Extended range (-6.7 to 48.9°C) operation

• Unit configuration can be ordered with, or converted to

• Microprocessor controls standard (optional DXM and/

front or back return and top, front, or back discharge.

or DDC controls)

Field conversion uses all existing parts including panels

• LonWorks, BACnet, Modbus and Johnson N2

and belts

compatibility options for DDC controls

• Electrical box can be field converted to be on front or

• Unit Performance Sentinel performance

back of unit

monitoring system

• Electric power can enter from any side of unit • Water and drain can be connected to either side • Dual refrigeration circuits (TL168, 192, 240, 300) • Exceeds ASHRAE 90.1 efficiencies • TXV metering device

Performance and Specifications AHRI/ISO/ASHRAE 13256-1 Data Water Loop Heat Pump Cooling 30 ºC

Model

Ground Water Heat Pump

Heating 20 ºC

Capacity WATTS

EER W/W

Capacity WATTS

TLV084

22,011

4.9

TLV096

24,971

4.8

TLV120

31,653

TLV150 TLV168

Cooling 15 ºC

COP

Capacity WATTS

EER W/W

Capacity WATTS

26,876

5.3

23,681

6.7

31,008

5.2

27,521

6.6

4.8

38,189

5.3

35,961

40,064

4.5

48,652

5.1

44,021

4.9

53,751

5.3

TLV192

49,941

4.8

62,016

TLV240

63,306

4.8

TLV300

80,129

4.5

Cooling 25 ºC

Heating 0 ºC

COP

Capacity WATTS

EER W/W

Capacity WATTS

COP

22,128

4.7

22,098

5.3

17,526

4.0

25,205

4.6

25,147

5.1

19,343

3.8

6.7

30,481

4.6

31,770

5.1

24,414

3.9

45,926

6.4

39,918

4.5

40,709

4.9

30,774

3.8

47,362

6.7

44,256

4.7

44,197

5.3

35,053

4.0

5.2

55,041

6.6

50,410

4.6

50,293

5.1

38,687

3.8

76,377

5.3

71,923

6.7

60,961

4.6

63,540

5.1

48,828

3.9

97,304

5.1

91,852

6.4

79,836

4.5

81,419

4.9

61,547

3.8

Cooling capacities based upon 27°C DB, 19°C WB entering air temperature. Heating capacities based upon 20°C DB, 15°C WB entering air temperature. All ratings based upon operation at lower voltage of dual voltage rated models. Note 1 - All TLV084 ratings at 1321 l/s with sheave settings at 3.5 turns open. Note 1 - All TLV096 ratings at 1510 l/s with sheave settings at 3.5 turns open. Note 1 - All TLV120 ratings at 1888 l/s with sheave settings at 3.5 turns open.

Voltage Options

Dimensional Data Vertical Model

Ground Loop Heat Pump

Heating 10 ºC

Overall Cabinet W

D

H

084 -150

cm

134.9

86.4

200.7

168 -300

cm

270.9

86.4

200.7

Vertical Model

Volts

Hz

Phase

084 - 300

380/420

50

3


M AT E M A S T E R W AT E R - S O U R C E H E AT P U M P S

aged Units

06/09B

ion History

Date

Item

ov, 2008

Various

Oct, 2008

Line Voltage

ept, 2008

CXM Control

une, 2008

Description

TC Data Added

Two Notes Added Below Tables and 460 Vac Note

Pressure Testing Note Updated

Low Volt Wiring Shut-Off Valve Note Added

ne, 2008

Various

May, 2008

CXM Control

ov, 2007

Line Voltage

ep, 2007

Various

uly, 2007

Various

23, 2007

Various

23, 2007

Various

ov, 2006

ov, 2006

Added 460 Vac Note to Electrical Tables Added Pressure Testing Language Note

Added TS 50Hz Electrical Data

Added Data for TS Size 006, 009, 012 Updated Metric Information

Added Data for TT Size 072

Updated TS Size 018 for Rev B

Added International Warranty

Added GS, GR, GC 50Hz Service Data

ov, 2006

Added ClimaDry Reheat Option Information

ov, 2006

uly, 2005

Various

uly, 2005

All

Added GS, GR, GC 50Hz Electrical Data

Updated Low Temperature Limit Verbiage First Published

ISO 9001:2000 Certified

BR I

HE

AT P U M P S

R

ST AND

3 ARD 1

6

-1

WATER TO

R AI

A TO NE

IS

O

7300 S.W. 44th Street Oklahoma City, OK 73179 Phone: +1-405-745-6000 Fax: +1-405-745-6058 climatemaster.com

IFIED TO ARI A RT S C CE

NG WITH LYI MP O IR

MANUFACT UR ER

Quality: First & Always

25

7300atS.W. 44thfor Street ClimateMaster works continually to improve its products. As a result, the design and specifications of each product the time order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Oklahoma Department at +1-405-745-6000 for specific City, OK 73179 information on the current design and specifications. Statements and other information contained herein are not express warranties and do not Phone: 405-745-6000 form the basis of any bargain between the parties, but are merely ClimateMaster’s opinion or commendation of its products. Fax: 405-745-6058

*97B0045N02* EP018

97B0045N02

© ClimateMaster, Inc. 2010

climatemaster.com Created: 31 August, 2010