ECKA 50/35/45L(h), 50/35/45R(h)
Technical data Version 11/2014
Operation when directly connected to chimney Tested according to
EN 13229
Nominal heat power
5,9 kW
Efficiency
> 80 %
Consumption of wood
1,9 kg/h
Mass flow of flue gas
5,4 g/s
Average flue gas temperature on the output
245 °C
Heat distribution fireplace insert door glass (single / double)
64–75 % 36 / 25 %
Required chimney pressure
12 Pa
Required amount of combustion air
20 m3/h
Minimum supply air grating cross-section
600 cm2
Minimum outgoing air grating cross-section
700 cm2
Operation with connected accumulation mass Load of wood
4,5 kg
Total heat output of the burning chamber
18 kW
Mass flow of flue gas
15 g/s
Average flue gas temperature 395 °C 162 °C
on the output 1) past 3,2 m of ceramic accumulation system KMS 240 2) Heat distribution fireplace insert door glass (single / double) adjoining accumulation mass
35 % 36 / 25 % 29–40 %
Required chimney pressure
12 Pa 45 m3/h
Required amount of combustion air
General technical information Ø 125 mm
Combustion air connection Total weight / lining weight Use in non-ventilated accumulation builds according to craft rules Meets values
175
(A)
- 116 (B) / 45 kg suitable
BImSchV (Stufe2), 15a BVG
1) The Hoxter products are available in the Austrian stove-calculation program for evaluation of firebrick accumulation systems. 2) Only a sample calculation! For accurate results is evaluation of each system in the KMS-calculation program from the Ortner company necessary.
1
Hoxter gmbh I Kirchgasse 1 I 912 17 Hersbruck I Germany I info@hoxter.de I +49 (0)9151 8659 163 Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
ECKA 50/35/45Lh
(A)
Technical data Version 11/2014
2
19
359
505
1 230
Hoxter gmbh I Kirchgasse 1 I 912 17 Hersbruck I Germany I info@hoxter.de I +49 (0)9151 8659 163 Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
240
50 - 110
450
1 110
943
M 1 : 10
ECKA 50/35/45Lh
(A)
Technical data Version 11/2014
50 - 110
35
Ø 125
3
1 110
943
M 1 : 10
Hoxter gmbh I Kirchgasse 1 I 912 17 Hersbruck I Germany I info@hoxter.de I +49 (0)9151 8659 163 Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
ECKA 50/35/45Lh
(A)
Technical data Version 11/2014 M 1 : 10
276
240
19
251
359
505
450
1 230
Ø 150
19 509 655
4
Hoxter gmbh I Kirchgasse 1 I 912 17 Hersbruck I Germany I info@hoxter.de I +49 (0)9151 8659 163 Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
ECKA 50/35/45L
(B)
Technical data Version 11/2014 M 1 : 10
214 Ø 150
240
350
445
1 043
50 - 110
500 595 5
Hoxter gmbh I Kirchgasse 1 I 912 17 Hersbruck I Germany I info@hoxter.de I +49 (0)9151 8659 163 Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701
445
1 043
450
943 1110
50
ECKA 50/35/45L
(B)
Technical data Version 11/2014 M 1 : 10
214 189
50
50 - 110
943 1110
50
25
Ø 125
6
Hoxter gmbh I Kirchgasse 1 I 912 17 Hersbruck I Germany I info@hoxter.de I +49 (0)9151 8659 163 Hoxter a.s. I Mlynska 326/13 I 602 00 Brno I Czech Republic I info@hoxter.eu I +420 518 777 701