5 minute read

1.4 The U.K.’s Approach to F-Gases

After the U.K.’s exit from the European Union, many wondered how this change would impact the refrigeration, air-conditioning, and heat pump (RACHP) industry, especially in relation to f-gas regulations.

Starting December 31, 2020, EU law, including F-gas Regulation No. 517/2014, no longer applied to the U.K. However, the U.K. has said it will follow the EU’s lead on revisions to the current EU F-gas Regulation and has also implied it may be willing to go even further in terms of ambition.17

Following Brexit, the U.K. Department for Environment, Food and Rural Affairs (Defra) has led the effort to draft the country’s f-gas regulation. A new regulation, however, is not expected to come into force before 2024.

Defra and the U.K.’s Environment Agency have a website for f-gas regulations.18 On August 2, 2022, the website updated guidance for applying for a quota to produce or import f-gas and to transfer and authorize an f-gas quota to another business.

On August 2, 2022, the website published a list of f-gas incumbent quota holders and authorization managers in Great Britain (England, Scotland and Wales) for the 2021 to 2023 reference period. It also published how to import, export or manufacture equipment pre-charged with f-gas.

In June 2022, the U.K. Climate Change Committee (CCC) called for the U.K. government to “match or exceed” the level of increased ambition that will be adopted following the revision of the EU F-gas Regulation. This was one of the messages contained in the 2022 Progress Report to the U.K. Parliament. The report pointed out major gaps in the implementation of policy measures supporting the U.K.’s net-zero goals. The report noted that the f-gas sector represented 3% (12Mt of CO2e) of total U.K. emissions in 2020. Even if credible policies to reduce f-gases are in place domestically, the CCC called for “stronger international action on reducing f-gas emissions, including health services in other countries,” referring to f-gases emissions released from the use of high-GWP HFCs in metered dose inhalers.

With regard to heat pumps, the CCC said, “Most heat pumps use f-gas refrigerants, which could become a significant source of f-gas emissions as heat pumps get rolled out across the U.K., unless the Government takes action to ensure that they shift to using non-F-gas refrigerants. Potential replacement refrigerants [to fluorinated gases] include propane and CO2.”

In May 2021, Defra held a stakeholder meeting to discuss plans to review the U.K.’s own f-gas regulation. Among the main takeaways from the meeting:

• The U.K. wants to align with new net-zero targets and ambitions.

• Defra will be working with customs to address illegal trade.

• The U.K. wants to propose “pragmatic, proportionate, and efficient” changes.

• The U.K. will set up sector-specific groups.

• Defra will see how the EU moves on f-gases to inform its proposal.

• Defra is aware of the trifluoroacetic acid (TFA) issue – HFO-1234yf degrades into TFA in the atmosphere – and is looking at existing and upcoming information.

The U.K. is motivated to be ambitious with f-gases to meet national expectations in regards to climate change. The nation also wants to be seen internationally as a leader in climate change and is counting on tackling f-gases as a way to reach this goal.

However, the U.K. is held back by being continuously compared to the EU, meaning it will have to be more ambitious than the EU if it wants to be seen as a global leader in climate change mitigation. In general, the U.K. appears to be more open to addressing specific issues such as air-conditioning or TFA where the EU is more hesitant. If the U.K. decides to be ambitious with its f-gas update, it could pave the way for the EU to be more ambitious as well. As a minimum impact, it would force a shift away from climate-polluting refrigerants in the U.K., driving accelerated adoption of natural refrigerant systems.

New sustainable and efficient production for high purity and competitive Hydrocarbon refrigerants

1.5 Hydrocarbon Charge Limits

In 2019, the International Electrotechnical Commission (IEC) voted to increase the allowable charge of hydrocarbons like R290 in commercial self-contained cases from 150g to 500g, updating its IEC 60335- 2-89 standard. The next step is for individual countries and regions to adopt their own version of the IEC standard.

CENELEC, which is responsible for publishing European (EN) standards, published the 500g charge limit for hydrocarbons in commercial cases under EN 600335-2-89 in August 2022.

But the standard must still be included in the list of harmonized standards with the EU Machine Directive (MD) before it can be used as a reference by industry; this could happen by the end of 2022, but more likely in 2023.

In the EU, the EN 378 (ISO 5149) general standard allows hydrocarbon charges up to 1.5kg in display cases, if rigorous safety precautions are taken. This standard has been invoked by U.K. retailer Waitrose, which employs display cases that include between 300g and 1,000g of propylene (R1270) charge per circuit, depending on the size and type of fixture. Every installation using EN 378 charge limits has to have a specific risk assessment for each system location. A similar standard does not exist in the U.S. or Japan.

More hydrocarbon case adoption?

A higher charge limit for R290 in commercial cases has long been considered a way to increase adoption of hydrocarbon equipment in supermarkets; this is particularly aimed at larger cabinets that currently use multiple circuits to compensate for the 150g charge limit. Commercial ice machines will also benefit from being able to use a larger charge of hydrocarbons.

However, the commercial cabinet industry has already been able to install millions of hydrocarbon cabinets in stores around the world using the 150g charge limit. The majority of self-contained cabinets are covered with 150g.

Manufacturers of large cabinets will be able to use a single circuit with the larger charge rather than multiple circuits. However, the larger charge is contingent on an appliance being constructed to prevent a flammable refrigerant concentration to surround the appliance in case of a leak, as verified by the “Annex CC” test. As a result, some manufacturers prefer the multiple-circuits approach instead of a higher hydrocarbon charge in one circuit.

This article is from: