QUICK INSTALLATION GUIDE

Page 1

IG0008_EN_ZERO RADIO V1.2

QUICK INSTALLATION GUIDE

ZERO RADIO

KIT CONTENTS • ZERO TRANSMITTER with battery and mounting bracket • ZERO RECEIVER • Quick installation guide • n°1 countersunk head screw Ø3,5 x 16 mm (optional upon request)

Installation steps: 1. Move the magnet on the bottom of the transmitter for "enable" the pairing mode. After activation the transmitter will begin to transmit the data level every 9 seconds for 10 minutes. At the end of 10 min the transmitter goes back in normal mode and transmits every 5 min. 2. Remove both screws that secure the level indicator and replace the rear screw (0% side) with a countersunk screw, with a maximum outside diameter of the head of Ø6mm, leaving it unscrewed by about 2mm.

RECEIVER

Fig.1

Fig.3 3. Place the Zero device by inserting it from the eyelets input from the bottom and pushing it forward.

POSITIONING AND FIXING ZERO RADIO TRANSMITTER must be properly fastened above the level indicator of the tank, using its same screws. It can’t be covered by snow or water (see notes and next steps for the installation). ZERO RADIO RECEIVER must be plugged into an electrical socket (110 or 230Vac) in a dry environment and protected from direct sunlight. For example it is possible to install it within a building, avoiding the basements because the radio transmission is shielded from the ground. The maximum distance between the ZERO RADIO TRANSMITTER and the receiver is 50m.

Fig.4

TRANSMITTER ASSEMBLY TOOLS For installation you need: • cross-head screwdriver and flat head screwdriver • magnet

INSTALLATION RECOMMENDATIONS AND SAFETY Shitek Technology Srl does not assumes responsibility for inappropriate or incorrect use of the device and / or not meet the safety requirements indicated. ZERO RADIO TRANSMITTER: the device is suitable for operation in Hazardous Area (Zone 0) according to the label: II 1 G Ex ia IIB T2 Ga operating temperature range: -20°C = Ta = +55°C. Do not rub or scratch the device plastic housing in order to avoid the occurrence of electrostatic charges (see rating plate located on the housing of the device). Use only approved battery packs supplied by the manufacturer. Install and/or replace the battery in a safe area after removing the Zero from its mounting and taken to a safe area at least 2 meters from the Hazardous Area. Do not place the device without the enclosure on conductive surfaces, it could damage irreparably even without a battery inserted. Periodically check the tightening and tightness of the seal of the closure device. Mainteinance in Hazardous Area must be performed by qualified and authorized personnel. Shitek Technology Srl reserves the right to check the personnel responsible for this function both adequately instructed with appropriate audit that can be planned with the direction. ZERO RADIO RECEIVER: Zero Radio has to be installed in ATEX safe zone. ZERO RADIO TRANSMITTER: INSTALLATION PROCEDURE The device can be installed on horizontal and vertical tanks (not double reading); Normally ZERO RADIO TRANSMITTER transmits the level and battery status every 5 min. If you activate the device with the magnet it enter in pairing mode: it transmits data every 9 seconds, the pairing mode duration is 10 min. Consequently activating the product with the magnet it is possible to quickly check data reception in the receiver.

Fig.2

4. Permanently lock the device, repositioning the front screw (50%side).

Fig.5 Not make holes in any part of the tank. Note: the device bases its level measurement on the magnetic effect that is present between the existent probe and its respective coupling with the rod inside the tank. It is recommended to replace the level indicator with a new one, since the measurement could be influenced by the quality and/or wear of the indicator exists. Shitek Technology Srl is not responsible of the quality and/ or measurement error if the technical conditions are not in accordance with the requirements. ZERO RADIO RECEIVER: INSTALLATION PROCEDURE 1.Plug the receive into the electrical outlet. 2.Until the receiver does not receive data from a transmitter, it will periodically turn on all segments of the display by drawing a circle. 3.When the receiver receives the first valid data (level and battery),it displays the level with two digits. If the level is lower than 20% the display flashes to indicate the minimum level alarm. 4. The "RX" red LED flashes whenever a valid data is received from the receiver. When the transmitter is in pairing mode (10 min maximum), the LED must flash every 9 seconds. If the receiver displays the level it is possible to start the configuration of the tank type. If the receiver remains in the initial state by turning on periodically all the display segments by drawing a circle perform the following operations: 1. Reactivate the transmitter with the magnet and wait some minutes. 2. Bring the receiver close to the tank. If the receiver shows "ER" it means that the data was received, but the measure made by the transmitter is not valid. In this case check the installation of the transmitter and the status of the glycerin level indicator.


IG0008_EN_ZERO RADIO V1.2

5. Press the "SET" button for 5 seconds and release it when the LED "RX" is on to check the type of tank set. If is displayed the words "LV" then it is set as vertical tank, if you see the word "LH" it is set to as horizontal tank. 6. If you want to change the type of tank, press the "SET" button for 5 seconds and release it when the LED "RX" is on, at this point the display will flash to indicate that is possible to change the tank type. 7. By clicking the "SET" button, the tank type switches between "LV" vertical and "LH" horizontal. Once it is selected the correct tank type wait 30 seconds, automatically the display will return to the level indication and will save the new configuration. The level indication will be updated when the receiver will receive a new valid data from the transmitter. ZERO RADIO RECEIVER MENU DESCRIPTION: By pushing the button it is possible to get access to a menu where the user can see the level and battery status and can see or change the device’s settings. Below is reported a scheme of the menu:

LEVEL (Ex 78)

click

BATTERY (Ex b3)

click

PAIRING (Ex P)

MENU "MEASURE"

Push 10s

Push 5s

LEVEL TYPE (Ex LV)

click

REPEATER (Ex ro)

Push 5s

Push 5s

Push 5s

LEVEL SETUP

PAIRING ACTIVE

REPEATER SETUP

Push 5s

Push 5s

Push 5s

MENU "VIEW SETTINGS"

MENU "CHANGE SETTINGS"

DEFAULT SETTINGS

It is possible to scroll the menu using the "SET" button, and checking the status of the LED "RX": - Click: clicking the “SET” button it is possible to change the screen displayed in a menu. - Push 5s: pushing the button for 5 seconds and releasing it when the LED "RX" is on, it is possible to change the menu’s type choosing between three main menus: 1. Menu Measure: show the level and the battery status. 2. Menu View Settings: show the device setup. 3. Menu Change Settings: access to modify the device setup. - Push 10s: pushing the button for 10 seconds and releasing it when the LED "RX" flashes (only in the level screen) it is possible to reset the device and restore the default settings. Below is described in detail each screen:

MENU MEASURE LEVEL: shows the level percentage of the tank level>20% → display always all. Ievel<20% → slow blink. level<10% → fast blink. If the level read by the transmitter it isn’t valid is shown the “Er” string. If the receiver hasn’t received any data, it turn on periodically all the display segments by drawing a circle. clicking the button → switch to “BATTERY” screen. pushing the button for 5 seconds → switch to the “View Settings” menu, “LEVEL TYPE” screen. pushing the button for 10 seconds → reset the device, and restore default settings. BATTERY: shows the charge of the battery 'b3' → battery fully charged. 'b2' → battery charged. 'b1' → battery discharged. 'b0' → battery fully discharged. clicking the button → switch to “LEVEL” screen. MENU VIEWS SETTINGS LEVEL TYPE: shows the type of the tank ‘LV’ → vertical tank ‘LH’ → horizontal tank clicking the button → switch to “PAIRING” screen pushing the button for 5 seconds → switch to the “LEVEL SETUP” screen. PAIRING shows if the device is paired ‘P’ → device not paired ‘PP’ → device paired clicking the button → switch to “REPEATER” screen pushing the button for 5 seconds → switch to the “PAIRING ACTIVE” screen where it is possible to associate a receiver with a transmitter. Note: when a transmitter is paired with a receiver, the receiver displays only the data received from the paired transmitter.

REPEATER: shows if the repeater function is activated ‘ro’ → repeater deactivated ‘rA’ → repeater activated If the repeater is activated the receiver retransmits the received data doubling the transmission distance. It is possible to use only one repeater for each transmitter installed. If the receiver is paired and has the repeater active, it retransmits only the data received from the paired transmitter. clicking the button → switch to “LEVEL TYPE” screen pushing the button for 5 seconds → switch to the “REPEATER SETUP” screen. MENU CHANGE SETTINGS LEVEL SETUP: this screen allow to change the type of tank The type of tank (‘LV’ → vertical tank; ‘LH’ → horizontal tank) is blinking. clicking the button → change the “LEVEL TYPE” between LH and LV pushing the button for 5 seconds → save the parameters. If the user don’t press the button for 30 seconds automatically the receiver return in the “LEVEL” screen and save the new parameter. PAIRING ACTIVE When the receiver enter in this state the screen shows a blinking 'P', and return automatically to unpaired state. Pushing the button for 5 seconds → exit from "PAIRING ACTIVE" state and return in “LEVEL” screen. If the receiver receive an pairing packet from the transmitter, it shows the blinking string ‘PP’, and after 10 seconds return to the “LEVEL” screen. If the user don’t press the button, or the receiver don’t receive any pairing packet from the transmitter after 10 minutes automatically the receiver return in the “LEVEL” screen. REPEATER ACTIVE: this screen allow to activate or deactivate the repeater funcion. The repeater activation state (‘ro’ → repeater deactivated ; ‘rA’ → repeater activated) is blinking. clicking the button → change the “repeater state” between ‘ro’ e ‘rA’ pushing the button for 5 seconds → save the parameters. If the user don’t press the button for 30 seconds automatically the receiver return in the “LEVEL” screen and save the new parameter.

PAIRING PROCEDURE If a receiver is not paired with a specific transmitter it displays the last valid data (level and battery) received from any transmitter. If a receiver is paired with a specific transmitter displays only the data received from the paired transmitter. If a receiver is paired and have the repeater function activated, it retransmits only the data received from the paired transmitter. 1. Activate the transmitter with the magnet (see picture Fig.2). After activation the transmitter will begin to transmit the data level every 9 seconds for 10 minutes. 2. Enter in the “PAIRING ACTIVE” screen 3. Wait that the receiver displays the blinking string ‘PP’ for 10seconds. 4. Check if the measured level is correct. 5. Return to the “PAIRING” screen and check if are displayed the ‘PP’ string. REPEATER INSTALLATION To double the transmission distance it is possible to install two receiver, and by configuring one of these as repeater. In this way the transmitter send the data to the receiver with the repeater function activated, that retransmits the data to the final receiver. Both the receiver will display the data (level and battery) received.

TRANSMITTER

REPEATER

RECEIVER

If the receiver with the repeater activated is not paired with the transmitter it will display and repeat every valid data received from all the transmitter installed near it. If the receiver with the repeater activated is paired with one transmitter it will display and repeat only the data received from the paired transmitter. Note: it is possible to install two or more repeaters at a mutual distance smaller than 300 meters only if each repeater is paired with a different transmitter. Note: don’t install two or more receiver with the repeater activated at a mutual distance smaller than 300 meters if they aren’t paired with a different transmitter. To reach the maximum transmission distance from the transmitter to the final receiver, the receiver with the repeater activated must be installed in the middle between the transmitter and the final receiver as shown in the previous figure.

Shitek Technology Srl via Malerbe, 3 - 36040 Grumolo delle Abbadesse (VI) - Italia Sede legale: Via San’Antonio, 45 - 35030 Veggiano (PD) - Italia www.shitektechnology.com - info@shitek.it