Quick Selection Guide Fire Systems LSN Periphery
Local SecurityNetwork Feature
• Easy wiring • Auto configuration capability (self-learning mode) • Central programming of all device configurations from the panel • Flexible network structure (Loop, stub, T-tap & mixed structure) • All cable types usable (Shielded & Unshielded cables)
• Reduced programming and installation cost and time
• Up to 3000 m line length • Up to 1.5 A current • Up to 254 elements per loop/line • Up to 127 elements per loop/line in LSN classic version
• Less installation time and cost through reduced number of loops • Increased number of loop powered devices
• Built-in diagnosis functions • Remote support is possible
• Easy and cost efficient maintenance and support
• Short circuit isolators in each device increase system integrity and cost savings
• One cable connects multiple areas • Can withstand a short or open circuit at any point in the loop and all devices still function
• Digital communication into every detector
• High security against tamper
• Addressable detectors • Automatic or manual address setting possible
• Easy operation • Way of address setting can be chosen depending on wiring
• One bus for intrusion, fire and malfunction
• Cost efficient installation, additional security
• Remote programming and maintenance
• Cost efficient and time saving
Benefit
• No special cable types needed, existing cables can be used
Special features LSN improved version
FS-OT-en-16_4998144899_11
Quick Selection Guide Fire Systems LSN Periphery
FAH-T 420 Heat Detector
FAP-O 420 Optical Smoke Detector
FAP-DO 420 Dual-Optical Smoke Detector
FAP-OT 420 Multisensor Detector Optical, Thermal
FAP-DOT 420 Multisensor Detector Dual-Optical, Thermal
FAP-OTC 420 Multisensor Detector Optical, Thermal, Chemical
FAP-DOTC 420 Multisensor Detector Dual-Optical, Thermal, Chemical
Feature • Combination of rate of rise and fixed temperature measurement • Central alarm LED visible from any direction • 2-wire device
• Light scattering principle • Drift compensation • Automatic pollution detection • Central alarm LED visible from any direction • 2-wire device
• Dual Ray technology Two light scattering smoke sensors with different wavelengths (infrared and blue LED) • Drift compensation • Automatic pollution detection • Central alarm LED visible from any direction • 2-wire device
• Combination of light scattering principle, rate of rise and fixed temperature measurement • Drift compensation • Automatic pollution detection • Central alarm LED visible from any direction • 2-wire device
• Dual Ray technology (see FAP-DO 420) in combination with rate of rise and fixed temperature measurement • Drift compensation • Automatic pollution detection • Central alarm LED visible from any direction • 2-wire device
• Combination of light scattering principle, rate of rise and fixed temperature measurement as well as combustion gas detection • Drift compensation • Automatic pollution detection • Central alarm LED visible from any direction • 2-wire device
• Dual Ray technology (see FAP-DO 420) in combination with rate of rise and fixed temperature measurement as well as combustion gas detection • Drift compensation • Automatic pollution detection • Central alarm LED visible from any direction • 2-wire device
Benefit • Error free alarm signals which virtually eliminate the occurrence of false alarms • Used where an open, fast-developing fire might occur • Detection of test fire TF1
• Error free alarm signals which virtually eliminate the occurrence of false alarms • Used where a smoldering fire might occur
• Error free alarm signals which virtually eliminate the occurrence of false alarms • Used where equal response to different types of fire is essential • Detection of test fire TF1
• Error free alarm signals which virtually eliminate the occurrence of false alarms • Used where open, fastdeveloping fires, as well as smoldering fires, might occur • Detection of test fire TF1
• Error free alarm signals which virtually eliminate the occurrence of false alarms • Used in environments with varying conditions • Detection of test fire TF1
• Error free alarm signals which virtually eliminate the occurrence of false alarms • Used where CO gas might harm people • Detection of test fire TF1
• Error free alarm signals which virtually eliminate the occurrence of false alarms • Used in environments with special conditions to maintain, and where CO gas might harm people • Detection of test fire TF1
FS-OT-en-16_4998144899_11
Quick Selection Guide Fire Systems LSN Periphery
FAP-OC 520 Smoke Detector
FAP-OC 520-P Smoke Detector
FAP-O 520 Smoke Detector
FAP-O 520-P Smoke Detector
FAD-O 420 and FAD-HS 420 EN Duct Detector
Feature • Light scattering principle in a virtual chamber • White housing • Multi-sensor detection in a combination of combustion gas and scattered-light sensor • Central alarm LED visible from any direction • 2-wire device
• Light scattering principle in a virtual chamber • Multi-sensor detection in a combination of combustion gas and scattered-light sensor • Color rings can be fitted into the detector to adapt to the ceiling • Central alarm LED visible from any direction • 2-wire device
• Light scattering principle in a virtual chamber • White housing • Central alarm LED visible from any direction • 2-wire device
• Light scattering principle in a virtual chamber • Color rings can be fi tted into the detector to adapt to the ceiling • Central alarm LED visible from any direction • 2-wire device
• Use in ventilation systems with air velocities from 1 m/s to 20 m/s • For the activation of fans, door controls or external display devices an optional relay board can be installed • A clear section on the frosted cover allows to view alarm LED of integrated FAD-O 420 detector • Tamper control • 2-wire device
Benefit • Unobtrusive design • Easy to clean • Enhances the appearance of architecturally attractive rooms • Ideal for dust-sensitive areas • High stability against disturbance values
• Unobtrusive design • Easy to clean • Enhances the appearance of architecturally attractive rooms • Ideal for dust-sensitive areas • High stability against disturbance values
• Unobtrusive design • Easy to clean • Enhances the appearance of architecturally attractive rooms • Ideal for dust-sensitive areas
• Unobtrusive design • Easy to clean • Enhances the appearance of architecturally attractive rooms • Ideal for dust-sensitive areas
• Easy installation in air ducts • Allows smoke detection in demanding environments
FS-OT-en-16_4998144899_11
Quick Selection Guide Fire Systems LSN Periphery
FAS-420-TM Aspirating Smoke Detector
FMC-210 DM/SM Manual Call Point
FMC-420RW Manual Call Point
FMC-420RW Manual Call Point Outdoor
FAS-420-TP Aspirating Smoke Detector
FAS-420-TT Aspirating Smoke Detector
Feature • Display sensitivity can be set to 0.05 %/m light oscuration • RoomIdent – fire localization • 10 level smoke density display • Innovative air flow sensor technology • High Power Light Source • 4-wire device • Max. 8 aspiration openings and 40 m or 2x25 m pipe lenth
• Display sensitivity can be set to 0.015 %/m light oscuration • 2 detector modules possible • Innovative air flow sensor technology • High Power Light Source • 4-wire device • Max. 48 aspiration openings and TP1: 300m; TP2:560m (2x280m) pipe lenth
• Display sensitivity can be set to 0.0015 %/m light oscuration • 2 detector modules possible • Innovative air flow sensor technology • High Power Light Source • 4-wire device • Max. 48 aspiration openings and TT1: 300m; TT2: 560m (2x280m) pipe lenth
• Different colors • Single and double action • Indoor and outdoor versions • 2-wire device
• Different colors • Resettable or with glass pane • Single-action call point • Indoor and outdoor (IP67) versions • 2-wire device
• Red color only • Resettable or with glass pane • Single-action version • EN54-11 and EN54-17 compliant
Benefit • Very early smoke detection even under challanging environmental conditions • Minimalization of false alarms due to intelligent signal processing • Easy maintenance and service no interruption of regular operations • Up to 5 rooms can be individually monitored
• Very early smoke detection even under challanging environmental conditions • Minimalization of false alarms due to intelligent signal processing • Easy maintenance and service no interruption of regular operations • 2-detector-dependency
• Very early smoke detection even under challanging environmental conditions • Minimalization of false alarms due to intelligent signal processing • Easy maintenance and service no interruption of regular operations • 2-detector-dependency
• High flexibility • Can be used for fire and other types of manual alarms
• High flexibility • Can be used for fire and other types of manual alarms
• High flexibility • Protection category according to EN 60529: IP67
FS-OT-en-16_4998144899_11
Quick Selection Guide Fire Systems LSN Periphery
FNM-420-A-BS-WH / FNM-420-A-BS-RD Base Sounder
FNM-420-A- WH / FNM-420-A-RD Stand-alone Sounder Indoor
FNM-420-B-RD Stand-alone Sounder Outdoor
Feature • 2 types: red and white • 90 dB with current < 5 mA • Constant sound pressure level in case of voltage drop • Immediate and permanent synchronization of different sounder groups within one loop • 32 tones • Different sound pressure levels • Combination with detector/Beacon
• 2 types: red and white • 100 dB with current < 5 mA • Constant sound pressure level in case of voltage drop • Immediate and permanent synchronization of different sounder groups within one loop • 32 tones • Different sound pressure levels • Double entry back box for simplified installation
• Red colour only • Outdoor type with IP66 • 100 dB with current < 5mA • Constant sound pressure level in case of voltage drop • Immediate and permanent synchronization of different sounder groups within one loop • 32 tones • Different sound pressure levels • Double entry back box for simplified installation
• Addressable strobe • Freely configurable • Combination with detector base or with LSN base sounder • Low current consumption of 6 mA • 2-wire device
Benefit • > 50 sounders per loop • European tones covered • Easy installation (sounder snaps into pre-installed mounting plate) • Special mounting plate for surface mounted cabling • Installation costs reduced by mounting detectors or beacons into the base sounder
• > 50 sounders per loop • Very high, consistent sound pressure level at low power • European tones covered • Easy installation (comfortable back box with knock-outs and space for cabling) • Very robust design
• > 50 sounders per loop • Very high, consistent sound pressure level at low power • European tones covered • Easy installation (comfortable back box with knock-outs and space for cabling) • Very robust weather-proof design
• Allows integration with • Maximum light at 1 Hz technical alarms (e.g. frequency for high level freezer, air condition) of visibility • Low current consumption • The various monitoring types ensure customized allows connection of a applications large number of peripheral elements
FNS-420-R Strobe
FLM-420-I2 Input Interface Module • 2 monitored inputs • Available as in-built, wall-mount and DIN-rail version • Contact or voltage monitoring • Line monitoring with use of EOL resistor • 2-wire device
FLM-420-O2 Output Interface Module
FLM-420/4-CON Conventional Interface Module
• 2 open collector outputs • Available as in-built, wall-mount and DIN-rail version • Max. switchable current per output 700 mA • Max. switchable voltage per output 30 V DC • Outputs are electrically isolated from LSN-loop and short-circuit proof • 2-wire device
• 2 fire zones class B or 1 fire zone class A • Available as wall-mount and DIN-rail version • 200 mA max. supply current per Aux-output • switchable Aux for resetting 4-wire detectors • 4-wire device
• Flexible control of external devices
• One class A or two class B zone • Provides integration of conventional fire alarm periphery into LSN systems • Compatible with 2- and 4-wire detectors • Can be used with a wide range of conventional detectors
FS-OT-en-16_4998144899_11
Quick Selection Guide Fire Systems LSN Periphery
FLM-420-RLV1 Relay Interface Module Low Voltage
FLM-420-RHV Relay Interface Module High Voltage
FLM-420-NAC Signaling Device Interface Module
FLM-I 420 Short Circuit Isolator
Feature • 1 low voltage relay 30 V/1 A • LSN improved version • Available as in-built, wall-mount and DIN-rail version • 2-wire device
• Isolation of short circuits • 1 supervised output line • 2 high voltage relays on LSN-Line reversed polarity with up (240 V/10 A) • 2-wire device to 3 A • 2 supervised feedback • Available as surface mount lines and DIN-rail version • Available as surface mount • 4-wire device and DIN-rail version • 2-wire device
Benefit • Control of external applications
• Supervision and control of external applications e.g. extinguishing systems
• Supervised control of signaling devices • Easy monitoring and activating of signaling devices
• Isolator for T-tap-systems • Functionality of the remaining network is preserved
FLM-420-RLV8-S Octo-relay Interface Module Low Voltage
FLM-420-O8I2-S Octo-Output Interface Module with 2 Inputs
FLM-420-I8R1-S Octo-Input Interface Module with Relay
• Eight change-over contact relays provide potentialfree contact outputs • Maximum switching capacity of the relays 2 A / 30 V DC • 2-wire device
• Eight individually switchable open collector outputs • Max. switchable current per output 700 mA • Outputs electrically isolated from LSN loop and short circuit proof • Individually selectable monitoring functions (EOL or contact) for the two inputs each • 2-wire device
• Individually selectable monitoring functions (EOL or contact) for each of the 8 inputs • Maximum switching capacity 2 A / 30 V DC • 2-wire device
• Easy wiring thanks to pluggable terminal block • Control of external applications
• Easy wiring thanks to pluggable terminal block • Control of technical LED-tableaus
• Easy wiring thanks to pluggable terminal blocks • Integration of technical alarms
FS-OT-en-16_4998144899_11
Quick Selection Guide Fire Systems LSN Periphery
FLM-420-RLE-S Interface Module
FLM-420-O1I1 Output-Input Interface Modules
FK 100 LSN RF Interface Module
DOW 1171 Radio Smoke Detector
MPA Detector Remote Indicator DIN 14623, ATEX PTB01, ATEX 2163X
FAA-RI 420 Remote Indicator
Feature • 1 low voltage relay (30 V, 1 A) • 2 supervised input lines • 1 input line programmable as relay feedback • DIN-rail mountable • Delivered with housing for surface mounting
• Open collector output electrically isolated from LSN loop and short-circuit proof • Max. switchable current per output 700 mA • Individually selectable input monitoring functions (EOL, contact or voltage) • 2-wire device
• Connection of up to 30 wireless detectors • Bi-directional data transfer • 868-870 MHz short range device • Transmission path monitoring • LSN classic • 4-wire device
• Deception-proof operating behaviour • High resistance to e lectro magnetic interference, temperature changes, humidity, corrosion and contamination • Smoke detector with outstanding interference immunity • Conntectable to FK-100-LSN
• Good visibility • Elegant, robust and efficient design • Easy localization of detectors • Compatible to LSN-classic and LSN improved
• Good visibility • Elegant, robust and efficient design • Easy localization of detectors • Compatible to LSN-classic and LSN improved
Benefit • Supervision and control of external applications, e.g. extinguishing systems • Conformity to VdS 2496: 2005 • Low supply current
• Available as in-built and DIN-rail version • Control of external devices
• Easy expansion of existing fire alarm systems • High transmission and functional security • Outstanding interference immunity
• Easy extension of existing fire alarm systems without additional wiring
• VdS approved • Parallel indication for detectors in false ceilings • Mounting in corridors or access pathways
• Parallel indication for detectors in false ceilings • Mounting in corridors or access pathways • Cost-efficient solution
FS-OT-en-16_4998144899_11