Maxiris 2000

Page 1

MA XIRIS 20 0 0 Network Infrared barriers EASY INSTALLATION Integrated alignment tools. Installation by one person.

RELIABILITY Synchronization and multiplexing of beams.

PRODUCT LINE 5 types of columns. 6 heights from 1.1 m to 5 m.

PRINCIPLE Invented and developed by SORHEA, MAXIRIS 2000 is the first infrared column on the market equipped for network management. The reliability of detection (up to 32 beams per barrier), combined with remote management and maintenance, makes MAXIRIS 2000 a high performance exterior infrared column. This line of proc ducts offers a column height up to 5 m, thereby making it i adaptable for all possible configurations. configuratio For precise analys analysis of beam interruptions, the column also includes a time-stamped t last 100 events. real-time log of the i equipped with simpliMAXIRIS 2000 is t fied alignment tools, allowing one individual to perform the adjustment:

22 | SORHEA 22 | SO SORHEA Catalogue Prof Pr Professional ofessional of Professionnel catalogue catal alogue

» optical sighting on each cell. » visual and audio indicators of the alignment level, » output for calibration of the incoming signal level for each receiver using a back alignment transmitter.

APPLICATIONS The reliabilit y and modular it y of the M A XIRIS 2000 columns allows ins tallation on the major it y of sites: » sur veillance of militar y ins tallations , nuclear plants , pr isons , etc. » sur veillance of supply bases » protec tion of subways , air por ts , etc.


i n f r aproducts red Barrières Bar rières Infrared res infrarouge infra frarouge barriers

» THE MAXIBUS NETWORK

R/R

R/T

T/T Hub T/T

Alarm center R/R R/R T/T

POWER SUPPLY HUB - CONTROL PANEL connection Cable SYT1

M A XIRIS 2000 is the f ir s t net wor ked infr ared column. Net wor k management is achieved via the MA XIBUS hub, which centr alizes the alar m ter minals for the entiret y of the receiver columns connec ted to the net wor k . Using a connec ted PC or a dedicated ter minal, it is possible to change the conf igur ation of each column (ope r ating mode, response time, etc.) to conf igure them relative to the site installation and per for m maintenance. Net wor k ing the bar r ier s , thank s to the MA XIBUS hub, of fer s the advantage of simplif ied wir ing, in addition to remote diagnosis of the sys tem.

Modif ication of the set tings is car r ied out thank s to the maintenance ter minal TM1711 or by using a PC equipped with the WINMA XI sof t ware application. The pr incipal set tings that can be changed are: » !"#"$ %&'&( ')"# * %+,-$ %&'&( ')"# * tr i- detec tion » response time of beams (bet ween 40 ms and 1 sec.) » time- delay for the low beam (40 ms and 5 sec.) » ejec tion of 1 or more beams » time - delay for the fog detec tor (1 sec . and 4 min .)

NETWORK: Twisted pair shielded cable Section 0.34 x mm2 SYNCHRONIZATION Cable SYT1

Min. 1.1 m

Max. 5m

Detection level » Multiple conf igur able levels of detec tion. » Mono- detec tion, dual- detec tion, tr i- detec tion. » Up to 32 entirely conf igur able beams .

Detection height

4 to 32 beams

Mono-/DualTri-detection

TECHNICAL SPECIFICATION Exterior range Height of columns Number of Beams Control Method for beams Power supply

Alarm information

Operating temperature Protection index

100 m 2.50 m 3 m 3.80 m 5 m 4 to 32 Multiplexed and synchronized via wire link ../ 0,( * 12/ 0,( $ 3/ 45*6/ 45

1.10 m

1.90 m

Intrusion 7)89+,-):(,')"# Tamper External alarm inputs (ex: Anti-climbing cap) Technical alarm “no power” -35°C to +55°C IP335

| 23