Perimeter Detection Systems
MAXIRIS 3000 / 3100 High Performance Infrared Barriers
ib
ar
W
us
30
e En
ir e
l
00
rg
y
n Zo
s es
I . S lo D. no ch Te
M
i ax
bu
gy So
l
ar
s
30
00 Zo
e En
r
ni
IP
ng
IP
IP
gy
ch Te
n
o ol
in
gy
c Te
h
g
l no
og
y
IR
le o ip h n r T ec T
g
n ni ZONING and IP Technology Zo IP
Innovative Zoning Function IP Technology for Maintenance and
ro chque n i S y pt O
W
ir e
le
IRSet up at distance o
IP
y og r l e o h l c re no ip h n y n il a i ch Tr ec S e T T Modularity withF 2 different frames available IP
ss
active fence
High detection performance technology
I . S lo g D. no ch Te
y
o hrr e c n ai Sy Fil
IR
Maxiris 3000
infrared
le o ip hn technology r T ec T
video analysis
Maxiris 3100
Modularity
1
zo n
e
2
zo n
e
ZONING Fonction
zo n e
3
The MAXIRIS 3000/3100 infrared barriers propose 2 different frames, to adapt to every site configuration. MAXIRIS 3000 Maxiris 2000 frame Simple face column Up to 36 beams per direction Zoning: from 4 to 10 cells per column (top beam left uncut) Adapted column height :
SF : Single Face DF : Double Face SD : Single Direction DD : Double Direction
SF / SD
Maxiris 3000 SF / SD
Up to 3 detection zones with adjustable length
Maxiris 3000 SF / DD
Optimized control of cameras
SF / DD
1,10 m (3.6 ft)
8 Beams
-
1,90 m (6.2 ft)
18 Beams
8 Beams
2,50 m (8.2ft)
24 Beams
12 Beams
3 m (9.2ft)
32 Beams
14 Beams
3,80 m (12.5 ft)
36 Beams
18 Beams
117 mm (4.6 ft)
115 mm (4.5 ft)
115 mm (4.5 ft)
117 mm ( 4.6 ft)
Rx /Tx Rx /Tx
Beams per direction
110 Vac / 60Hz
MAXIRIS 3100 Maxiris III frame Simple and Double Face column High density of beams : max 64 beams per 3 m column in double direction Zoning: from 4 to 10 cells per column (top beam left uncut) Adapted column height R
Cables - 1 pair synchronization (700m (2296 ft) maxi per barrier) - 1 pair RS485 (1200m (3938 ft) maxi per Network)
230 Vac / 50Hz 110 Vac / 60Hz 230 Vac / 50Hz
Rx /Tx
x
/Tx
Maxiris 3100 SF / SD
Maxiris 3100 SF / DD
Alar Co n m tr Pa n o l nel
110 Vac / 60Hz
Maxiris 3100 DF / DD
MA X
110 Vac / 60Hz
IBUS
30 0 0
230 Vac / 50Hz
Fibe r App Optic licat ion
Sup
ervis
or
230 Vac / 50Hz Rx /Tx
ETH
ERN
ET
TCP NET /IP WO RK
G App SM licat io
ns 110 Vac / 60Hz
Rem
ote PC
Beams per direction 160 mm (6.3 ft) 110 mm (4.3 ft)
110 mm (4.3 ft)
160 mm (6.3 ft)
110 mm (4.3 ft)
SF / SD
190 mm (7.5 ft)
SF / DD
DF / DD
1 m (3.3 ft)
6 Beams
-
6 Beams
2 m (6.6 ft)
20 Beams
10 Beams
20 Beams
2,50m (8.2 ft)
24 Beams
12 Beams
24 Beams
3 m (9.8 ft)
32 Beams
14 Beams
32 Beams
230 Vac / 50Hz
W App IFI licat io Main tena n PC ce
ns
Rx /Tx
110 Vac / 60Hz 230 Vac / 50Hz
High Performance Infrared Mixed cells Transmitter/Receiver Single / Dual / Triple Detection Bottom beam control Detection transfered to next beam in the event of an ejected zone
IP Technology The MAXIBUS 3000 hub has an Ethernet connection. Each MAXIRIS 3000/3100 column can be set up locally or at distance thanks to the integrated web server. Maintenance and set up at distance Alarm log history Graphical view of the columns on site (optional cartography)
TECHNICAL CHARACTERISTICS MAXIRIS 3000
MAXIRIS 3100
Inside maximum range
500 m (1640 ft)
Outside maximum range no matter what the weather conditions
100 m (328 ft)
Height of the columns
1,1 m
2m
2,5 m
3m
3,8 m
1m
2m
2,5 m
3m
3.6 ft
6.6 ft
8.2 ft
9.8 ft
12.5 ft
3.6 ft
6.6 ft
8.2 ft
9.8 ft
Intrusion alarm information
Up to 3 intrusion zones (distance can be configured)
Alarm outputs
RS 485 on each column, compatible with MAXIBUS III Ethernet (RJ45 in each column) compatible ModBus TCP/IP server/client Dry contacts output: from 8 up to 136 relays maximum per hub
Power supply
110 Vac/230 Vac - 60 Hz/50Hz
Alignment tools
Buzzer and leds inside each column
Operating temperatures
From -35°C (-31 F°) to +70°C (+158°F) - Thermostatic heater in each column
Electro magnetic compatibility
In compliance with European standards (CE approval)
Configuration tools
• Integrated web server inside each column • Integrated web server inside the MAXIBUS III hub: access at a distance via internet connection
HTML server functions
• Password protection • Reading/Entry of the parameters • Visualization of the log history and the state of the barrier
Configuration Example
Example with 5 columns, 2.5 m (8.2 ft), 4 cells, Network, closed loop, 3 detection zones per barrier Rx /Tx ZON E
1 ZON E
2 ZON E
Rx /Tx MAX IBU
S 30
00
Rx /Tx
3
2,5 m (8.2 ft)
Rx /Tx
Rx /Tx
MAXIRIS 3000
MAXIRIS 3100
Columns
5 x column 2m50 (8.2 ft) SF/DD 6E/6R - Ref : 30700306
5 x column 2m50 (8.2 ft) DF/DD 6E/6R - Ref : 30701308
Brackets
5 x pole 2m50 (8.2 ft) - Ref : 35205200
5 x Floor sockets - Ref : 30580001
Required parts
Hub Extension cards
1 x Universal hub MAXIBUS III - Ref : 40670006 3 x Extension cards - Ref : 35588419
Options Back up battery
5 x Ref : 35145000
Anti-climbing cap
5 x CAA 360° - Ref : 35180300
5 x CAA 360° - Ref : 30580004
Cable protection
5 x Cable protection - Ref : 35172805
Included in the frame
Seal of the retailer NC217-EN V2.0 06.15
In order to continuously ensure the high standard of quality and performance of our products, we reserve the right to modify the present technical data without notification.
1 rue du Dauphiné - 69120 VAULX-EN-VELIN - FRANCE Tél. : +33(0)4 78 03 06 10 Fax : +33(0)4 78 68 24 61 e-mail : export@sorhea.com
www.sorhea.com www.sorhea.fr