Installed Performance of Dual vs. Single Stage Ducted Fan Thrusters at Low Speed

Page 1

Installed Performance of Dual vs. Single Stage Ducted Fans at subsonic speeds Sina Golshany 12/09/2018


Dual vs. Single Stage Ducted Fans

Dual-Stage, Contra Rotating Ducted Fan

Single-Stage, Ducted Fan with guide vanes


Single Stage Net Thrust vs. Airspeed & RPM

Air Speed [m/sec]:


Single Stage Net Thrust vs. Airspeed & RPM


Single Stage Net Efficiency vs. Airspeed & RPM

Air Speed [m/sec]:


Single Stage Net Efficiency vs. Airspeed & RPM


Single Stage Fan Torque vs. Airspeed & RPM

Air Speed [m/sec]:


Single Stage Fan Torque vs. Airspeed & RPM


Single Stage Fan Performance Sensitivity 2 m/sec airspeed and 6800 RPM


Single Stage Fan Performance Sensitivity 10 m/sec airspeed and 6800 RPM


Single Stage Fan Performance Sensitivity 18 m/sec airspeed and 6800 RPM


Single Stage Fan Performance Metrics 2 m/sec airspeed and 6800 RPM


Single Stage Fan Performance Metrics 10 m/sec airspeed and 6800 RPM


Single Stage Fan Performance Metrics 18 m/sec airspeed and 6800 RPM


Dual Stage Net Thrust vs. Fore/Aft Fan Speed Airspeed 2 [m/sec]

Aft Fan Speed [rad/sec]


Dual Stage Net Thrust vs. Fore/Aft Fan Speed Airspeed at 2 m/sec


Dual Stage Net Efficiency vs. Fore/Aft Fan Speed Airspeed 2 [m/sec]

Note: Efficiency values above 100% are an artifact of interpolation errors in the fringes of the design exploration space.

Aft Fan Speed [rad/sec]


Dual Stage Net Efficiency vs. Fore/Aft Fan Speed Airspeed 2 [m/sec]


Dual Stage Net Efficiency vs. Fore/Aft Fan Speed Airspeed 18 [m/sec]

Aft Fan Speed [rad/sec]


Dual Stage Net Efficiency vs. Fore/Aft Fan Speed Airspeed 18 [m/sec]


Dual Stage Net Thrust vs. Fore/Aft Fan Speed Airspeed 18 [m/sec]

Aft Fan Speed [rad/sec]


Dual Stage Net Thrust vs. Fore/Aft Fan Speed Airspeed at 18 m/sec


Dual Stage Fan Performance Sensitivity 2 m/sec airspeed and 6000 RPM


Dual Stage Fan Performance Sensitivity 10 m/sec airspeed and 6000 RPM


Dual Stage Fan Performance Sensitivity 18 m/sec airspeed and 6000 RPM


Single Stage Fan Performance Metrics 2 m/sec airspeed and 6800 RPM


Single Stage Fan Performance Metrics 10 m/sec airspeed and 6800 RPM


Single Stage Fan Performance Metrics 18 m/sec airspeed and 6800 RPM


Point Design Performance Comparison • Three comparisons are performed. Optimal RPM, (fore/aft for the dual fan) are computed to identify the highest efficiency point at three design speeds: • 2 m/sec (stationary maneuvering), 30 [lbf] • 10 m/sec (transition to cruise), 30 [lbf] • 15 m/sec (cruise), 30 [lbf]

• A Multi-Objective Genetic Algorithm (MOGA) is used to identify best of 3 candidates out of 3000 initial samples, subject to the following criteria: • 29.75 [lbf]< Net Force < 30.25 [lbf] • Maximize Net Efficiency • Seek Airspeed Equal to the objective (2,10, or 15 m/sec)


Point Design Performance Comparison • Single Fan Optimal Combinations: Condition:

2 [m/sec]

10 [m/sec]

15 [m/sec]

Forward Fan Speed [rad/sec]

740

780

820

Aft Fan Speed [rad/sec]

---

---

---

Net Efficiency [%]

87

68

53

Forward Fan Torque [N-m]

6.35

6.40

6.50

Aft Fan Torque [N-m]

---

---

---


Point Design Performance Comparison • Dual Fan Optimal Combinations: Condition:

2 [m/sec]

10 [m/sec]

15 [m/sec]

Forward Fan Speed [rad/sec]

629.8

744.7

746.9

Aft Fan Speed [rad/sec]

708.6

534.6

730.1

Net Efficiency [%]

97

65

53

Forward Fan Torque [N-m]

1.10

5.10

2.72

Aft Fan Torque [N-m]

-5.52

-1.699

-4.71