11 minute read
Softener accessories
15000205-08 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 8lt. resin 15000205-12 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 12lit. resin 15000205-15 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 15lt. resin 15000205-20 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 20lt. resin 15000205-25 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 25lt. resin 15000205-30 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 30lt. resin 15000205-40 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 40lt. resin 15000205-50 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 50lt. resin 15000205-60 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 60 liters resin 15000205-70 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 70 liters resin 15000205-75 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 75 liters resin 15000205-80 BNT1650F Single tank water softener valve 1" electronic (Reg. Metered-time) 80 liters resin
Code: 000092
Advertisement
Yellow drain tube for water softener 1/2"
Sold by the meter Features • Ø 12,5 mm (1/2") • Flexible • Anti alga • Operating temperatures from -10°C to 40°C • Pressure 8 Bar 8 years warranty Code: 000093
Yellow drain tube for water softener 3/4"
Sold by the meter Features • Ø 19 mm (3/4") • Flexible
• Anti alga • Operating temperatures from -10°C to 40°C • Pressure 8 Bar • 8 years warranty Code: 15000421
Overflow Elbow 90° / Thread ring 3/8" - Black
Code: 15000411
Overflow Elbow 90° / Thread ring 1/2"
Code: 15000407
Chlo Active CL2 complete chlorine maker with Titanium electrode, o-ring, Starfit fittings 3/8"
OPERATION: Connect the probe on your softener brine line (use the necessary adapters). Check how many liters of resin are there in your softener (look on softener manual). Make sure that the plug of Our generator is disconnected. On the generator's board there is a trimmer that can be setted from 1 to 70 minutes of timer. Every minutes that you program can disinfect 1 lt of resin. The system is ready to start. How it works: The softener during regeneration aspires the brine, our system feels the passage of brine and active electrolysis of NaCl for the time setted on the probe. After this time the generator is silent for 4 hours (ignoring the possible passage of brine). After this 4 hours the system is ready to re-disinfect the resins.
The green LED indicates the system voltage, the yellow LED indicates system disinfection. Code: 15000402
Chlo Active CL2 - components chlorine maker
Variants
Code Description
15000402-01 Chlo Active CL2 chlorine maker without electrode 15000402-02 Titanium electrode for Chlo Active with TEE 3/8" 15000402-03 TEE 3/8"
Replacement parts chlo active Articles to assemble: J173-CPR16IS JG replacement O-ring OD tube 1/2" (x3pcs.) + S001-4200 Straight adaptor OD Tube - M. thread 3/8" x 3/8" (x2pcs.) Code: 15000435
Specifications Power: 200mA Connection: QC 3/8" tube Total Chlorine Generation: 1.8ppm @ 2.0L/M Saturated Brine draw rate. Salt Alarming: Detect the salt volume in the brine tank simultaneously, alarm if salt is lack(85HE PCB only current).
Principal of Work The generator can be installed into the normal Brine Line to produce chlorine through electrolytic reaction during the Brine. Draw cycle, thus killing the bacteria or other relevant microbes that affect the water quality in the container or the solution, this periodic disinfection reduce the existence of all kinds of microorganisms in softener system.
Automatic disinfection system for water softener from 0 to 350 lt. resin.
An automatic chloration of ion exchangers in residential water softeners is already required in most European countries. Even if it is not always compulsory, a periodic chloration is often advised in order to avoid bacteriological growth, which can affect softened water characteristics. The automatic disinfection system for softeners Steril-Soft Pro:
* Generates chlorine by brine electrolysis during regeneration. * The chlorine gets in contact with the ion exchange resin at the same time as brine, ensuring regeneration as well as chloration. * Chlorine in excess is eliminated during the regeneration process. * This patented technology generates the electrolysis only during the brine draw cycle and stops automatically based on your own settings: once switched off, the device requires 20 minutes before starting another cycle. * Chlorine production can be set depending on the installation conditions. * We recommend to follow the chart below in order to set the device for the chlorine PPM required by your system. * Steril-Soft Pro can be used with any automatic valve with a 3/8" brine line. * The controller includes its own transformer as well as titanium electrodes. * The electrode cell is installed in the brine line.
Feature’s regulation box with cell: * Input voltage 230 VAC ± 10% * Output voltage: 2-6 VDC * Protection: IP44 * Automatic electrode polarization for each cycle. * Potentiometer for the intensity setting adjustable from 0.2 to 2.5 A * Potentiometer for cycle time setting adjustable from 2 to 20 minutes. * Complies with CE regulations 23/73 and 336/89
Feature’s electrode cell: * Titanium electrodes with linking cable. * Fiber glass reinforced polypropylene body. * Connections 3/8" compression fittings
Important: the time setting must be smaller than the brine draw cycle time otherwise there is a risk of heating and deterioration of the electronic cell.
One thermal probe is assembled on the cell in order to avoid any issue related to the temperature increase when the device is not producing chlorine. A perfect setting can only be done if the variable characteristics of the softener are taken into account (brine draw time, resin capacity, injector, etc). Use the following chart as a guideline to obtain the right set up. The chlorine production starts only when the conductivity on the probe reaches 18000 µS.
Installation and maintenance: * Remove the cover of the Steril-Soft Pro box. Set the outlet current by using the AMPERE potentiometer, then use the TIME potentiometer to set the cycle time. * Close the cover and connect the electrode cell to the Steril-Soft Pro box and fit it in the brine line. * Fix the Steril-Soft Pro box to a wall or on a bracket, close to a 230V/50Hz electrical supply. * Connect the brine line to the inlet and outlet of the electrodes cell. * Link the power cord to the Steril-Soft Pro box and plug to the mains. Check that the electrical power is not controlled by a switch. The green L.E.D. indicates that the Steril-Soft Pro is on. The red L.E.D. indicates chlorine production and only comes on during the brine draw cycle.
Set-up Instruction: * The adaptability of the Steril-Soft Pro for softeners up to 350 lt. of resin is obtained by setting in the TIME potentiometers inside the box. * The Ampere potentiometer (from 0.2A to 2.5A) regulates the amount of chlorine produced. The bigger the resin quantity is (similarly to the injector capacity), the more chlorine will have to be produced in order to ensure a sufficient chlorine concentration on the resin. * The Time potentiometer sets the chlorine production time from 2 to 20 minutes. When the device finishes the production it will remain switched off for 20 minutes before being ready for a new cycle. Code: 15000416
STERIL-SOFT - components chlorine maker
Automatic disinfection system for water softener from 0 to 90 lt. resin. Titanium electrode not included.
Code: 15000417
STERIL-SOFT - components titanium electrodes without cable for chlorine maker
Code: 15000418
Automatic disinfection system for water softener from 0 to 90 lt. resin.
Important: the time setting must be smaller than the brine draw cycle time otherwise there is a risk of heating and deterioration of the electronic cell.
Set-up Instruction: * The adaptability of the Steril-Soft for softeners up to 90 lt. of resin is obtained by setting in the TIME potentiometers inside the box. * The Ampere potentiometer (from 0.2A to 2.5A) regulates the amount of chlorine produced. The bigger the resin quantity is (similarly to the injector capacity), the more chlorine will have to be produced in order to ensure a sufficient chlorine concentration on the resin. * The Time potentiometer sets the chlorine production time from 2 to 20 minutes. When the device finishes the production it will remain switched off for 20 minutes before being ready for a new cycle. The fitting "T" to be assembled with the electrode and fittings Starfit is the code 15000402-03 Code: 15000436
Quick connector II spacer for BNT valves (25)
Dimension (ODxH): 99x63 mm.
Variants
Code Description
15000422-01 Upper bayonet screen basket OD 27mm. for Fleck
Code: 15000431
Upper bayonet screen basket OD 27mm. for Clack
Code: 15000406
Upper bayonet screen basket OD 21mm., OD 27mm.
Variants
Code Description
15000406-01 Upper bayonet screen basket OD 21mm. 15000406-02 Upper bayonet screen basket OD 27mm. (Standard)
Code: 15000432
Resin filling funnel
Code: 15000408
Resin filling funnel
Code: 15000433
PP alimentary bailer for resin refill - 34 cm.
Variants
Code Description
15000409-05 Safety brine valve with float 13" - 33cm. (3/8") slim 15000409-01 Safety brine valve with float 17" - 43,17cm. (3/8") 15000409-06 Safety brine valve with float 22" - 55,87cm. (3/8") slim 15000409-03 Safety brine valve with float 35" - 88,9cm. (3/8") 15000409-04 Safety brine valve with float 44" - 111cm. (3/8")
Code: 15000420
Code: 15000423
1600 brine valve 32,28" - 82cm. (3/8")
Variants
Code Description
15000439-01 Brine valve 17" - 43,17cm. (3/8") 15000439-02 Brine valve 35" - 88,9cm. (3/8") 15000439-03 Brine valve 44" - 111cm. (3/8")
The brine valve have to be chosen based on the height of the pressure vessel installed in the water softener. In any case, the valves are suitable by adjusting the height to the pressure vessel used. Just follow the instructions below:
15000439-01: Brine valve suitable for all the pressure vessels with height 17"
15000439-02: Brine valve suitable for all the pressure vessels with height 35"
15000439-03: Brine valve suitable for all the pressure vessels with height 44" Code: 15000427
Code: 15000429
Code: 15000426
Union elbow OD Tube - OD Tube 3/8"
Code: 15000413
Safety brine valve with float 2350 - 1/2"
Code: 15000424
Bottom screen basket OD 27mm.
Code: 15000438
Bottom screen basket OD 27mm.
Code: 15000425
Bottom screen basket tube OD 27mm. (1,05") x 3000mm.
Code: 15000430
Variants
Code Description
15000430-01 Bottom distributor pipe 1,05" + Bottom crepine 125 cm. (49,21") 15000430-02 Bottom distributor pipe 1,05" + Bottom crepine 195 cm. (76,77")
Code: 15000419
Variants
Code Description
15000419-01 Bottom distributor pipe 2,66 cm. (1,05") + Bottom crepine - 44 cm. (17") 15000419-02 Bottom distributor pipe 2,66 cm. (1,05") + Bottom crepine - 90,4 cm. (35") 15000419-04 Bottom distributor pipe 2,66 cm. (1,05") + Bottom crepine - 112 cm. (44") 15000419-05 Bottom distributor pipe 2,66 cm. (1,05") + Bottom crepine - 122 cm. (48") 15000419-03 Bottom distributor pipe 2,66 cm. (1,05") + Bottom crepine - 136,62 cm. (54")
Code: 15000414
Screen bottom distributor pipe 50mm. for vessels 21", 24" upper thread 4"
Code: 15000412
Standard Brine wells from 17" to 44"
Variants
Code Description
15000412-06 Standard Brine well 17" Ø 90 - 37cm. 15000412-08 Standard Brine well 35" OD 90 - 75cm. 15000412-10 Standard Brine well 44" OD 90 - 111,4cm.
Compatible with other cabinets: Standard 17" model (cod. 15000412-06) . Compatible with Dayton 12,5 liters Standard 35" model (cod. 15000412-08) . Compatible with Dayton 15, 18, 30 liters You can cut and adapt to different models. Cap included. Code: 15000440
PVC reduced sleeve OD 50x40 mm.
Code: 15000441