INDEX Membranes .......................................................................................................................................................... 3
Membranes Code: 090001
Filmtec membrane TW30 1812 - 50, 75, 100 GPD (25)
Variants Code
Description
090001-01 090001-02 090001-03
Filmtec membrane TW30 1812 - 50 GPD (25) Filmtec membrane TW30 1812 - 75 GPD (25) Filmtec membrane TW30 1812 - 100 GPD (25)
Code: 090005
Greenfilter membrane TW30 1812/2012/3012 - 50, 75, 100, 150, 180, 300 GPD (25)
Variants Code
Description
090005-50 090005-75 090005-100 090005-150 090005-180 090005-300
Greenfilter membrane TW30 1812 - 50 GPD (25) Greenfilter membrane TW30 1812 - 75 GPD (25) Greenfilter membrane TW30 1812 - 100 GPD (25) Greenfilter membrane TW30 1812 - 150 GPD (25) Greenfilter membrane 2012 - 180 GPD (25) Greenfilter membrane 3012 - 300 GPD (1)
Definition Reverse osmosis process is base don nature and has been used for more than 30 years. These semi-permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 µm. 2. Polysulfone 45 µm . 3. Non woven fabric polyester 100 µm. Spacer: EPDM
19 June 2014
3/9
SPECIFICATIONS OF PRODUCT Membrane 50 GPD Cod. 090005-50 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 75 GPD Cod. 090005-75 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 100 GPD Cod. 090005-100 Active surface: 0,46m²(5ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 150 GPD Cod. 090005-150 Active surface: x,xxm²(xft²) * Pressure 3,5bar(50psi) * Production flow(N1) 23,66 l/h(150gpd) * Salts rejection(N2) 97,5% * Recovery del 15% Membrane 180 GPD Cod. 090005-180 Active surface: x,xxm²(xft²) * Pressure 8bar(116psi) * Production flow(N1) 45,83 l/h(300gpd) * Salts rejection(N2) 93% * Recovery del 15% Membrane 300 GPD Cod. 090005-300 Active surface: x,xxm²(xft²) * Pressure x,xbar(xxpsi) * Production flow(N1) xx,xx l/h(300gpd) * Salts rejection(N2) 95% * Recovery del 15% (N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF), 15% recovery and specified applied pressure. Permeated flows for individual elements may vary +/- 15%. (N2) Minimum SALT rejection is 95% OPERATING LIMITS OF 50, 75, 100 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 21 bar (300 psi) * Max. P for element 1 bar (15 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * pH range, short-term cleaning (30 min) 2 - 11 * Max. Feed SDI 5 * Free Chlorine tolerance¹ <0,1 ppm OPERATING LIMITS OF 150, 180 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 8,6 bar (125 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * Free Chlorine tolerance¹ <0,1 ppm ¹Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We recommend replacing it every 24 months max. GENERAL INFORMATION • All membranes are tested strictly and vacuum sealed in a bag containing a solution of sodium-bisulphite and propylene glycol to prevent biological growth in short-term storage and transport. • It is suggested that firs hour of pure water to be rejected. • Keep elements moist after initial wetting. • To prevent biological growth during prolonged system shutdown, it is recommended that membrane elements be immersed in a preservative solution.
19 June 2014
4/9
• The membrane shows some resistance to short-term attack by chlorine (hypochlorite). Continuous exposure, however, may damage the membrane and should be avoided. • The customer is fully responsible for effects of incompatible chemicals and lubricants on elements. • Use just glycerine as a lubricant if is needed. • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design and on the operation and maintenance of the system. Code: 090007
AMI membrane 1812/3012 - 50, 75, 100, 150 GPD (25)
Variants Code
Description
090007-100 090007-150 090007-300
AMI membrane 1812 - 100GPD (25) AMI membrane 1812 - 150GPD (25) AMI membrane 3012 - 300GPD (25)
AMI Membrane home membrane elements, are among the finest in the industry. With hundreds of thousands of membranes in operation world-wide, we offer these in a large range of both residential and commercial sizes AMI Membranes are Made in the USA in our ISO 9001:2008 Certified Facilities. For the past 30 years AMI Membrane elements have earned the reputation of consistent quality. Recommended Operating Conditions (50, 75, 100, 150gpd) * Maximum operating pressure: 125 psi (8,61bar) * Maximum feed flow rate: 2 gpm (7,57lt./min.) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 5 * Chlorine tolerance: <0.1 ppm * Feed water pH range, Continuous Operation: 2-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Minimum brine flow to permeate flow ratio: 4:1 * Dimensions: 50, 75, 100gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,75"(4,57cm) * Dimensions: 150gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,95"(5cm) Note: Salt rejection and performance specifications shown are from internal test data. Performance specifications based on 500 ppm tap water, 50 psi (3,44bar) applied pressure, 77°F (25°C) feed water temperature, feed water pH 7-8 and 15% recovery. Element permeate flow may vary ± 20%. The 150 gpd membranes are designed for a tight fit in most standard housings. If the membrane fits loosely, you may need to wrap a few layers of tape near one end to make a tight fit. Recommended Operating Conditions (300gpd) * Maximum operating pressure: 300 psi (20,68bar) * Maximum feed flow rate: 6 gpm (22,71lt./min.) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 4 * Chlorine tolerance: <0.1 ppm
19 June 2014
5/9
* Feed water pH range, Continuous Operation: 2-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Single Element recovery: 15% * Dimensions: 300gpd A-11,75"(29,85cm) B-10,25"(26,03cm) C-3"(7,61cm) E-3,2"(8,12cm) Note: Note: Performance specifications based on, Tap Water, 77°F (25°C) feed water temperature, pH 8 and 10% recovery. Element permeate flow may vary ± 15%. Code: 090006
NF90-2012 nanofiltration membrane - 180 GPD (25)
Variants Code
Description
090006-01
NF90-2012 nanofiltration membrane - 180 GPD (25)
ALPSPRING offers a full line of RO membrane elements in polyamide composite. The polyamide composite membrane elements display an outsdanding salt rejection of more than 97% , superior product water flow , high thermal and pressure durability , wide tolerance of chlorine and PH. SPECIFICATIONS OF PRODUCT Membrane 180GPD Cod. 090006-01 NF90-2012 NaCl Rejection: >90% ±2% * MgSO4 Rejection >96% * Permeate flow rate: 180GPD Test condition Applied pressure: 150PSI(10,34BAR) * Feed water temperature: 25°C * NaCl Concentration: 500ppm * Recovery: 15% Operating limits Max. temperature 40ºC * Recovery range 10-20% * Maximum operating pressure 21bar(300 psi) * Operating PH range: 4-11 * Chlorine tolerance <0,1 ppm Caution Should not be storage in direct sunlight * The flux and rejection performance may take 24 to 48 hours to stabilized Code: 090008
AMI nanofiltration membrane 1812 - 150, 200 GPD (25)
19 June 2014
6/9
Variants Code
Description
090008-150 090008-200
AMI nanofiltration membrane 1812 - 150GPD (25) AMI nanofiltration membrane 1812 - 200GPD (25)
Nanofiltration Membrane Elements: NF5 What is Nanofiltration? Nanofiltration (NF), in concept and operation, is much the same as reverse osmosis. The key difference is the degree of removal of monovalent ions such as chlorides. Reverse osmosis removes the monovalent ions at 98-99% level at 200psi (13,78bar). Nanofiltration membranes’ removal of monovalent ions varies between 50% to 90% depending on the material and manufacture of the membrane. For this reason, there is a variety of Nanofiltration membranes available. Each type is particularly suited to a certain application and may not be acceptable to a different application. Nanofiltration membranes (NF membranes) and systems are used for water softening, food and pharmaceutical applications. Recommended Operating Conditions * Maximum operating pressure: 300psi (20,68bar) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 4 * Chlorine tolerance: <1 ppm * Maximum Pressure Drop: 13psi (0,89bar) * Feed water pH range, Continuous Operation: 4-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Average Salt Rejection: 50% * Average Hardness Rejection: +97% * Dimensions: L-11,75"(29,85cm) I-10,25"(26,03cm) D-3"(7,61cm) Note: Performance specifications based on 2000 mg/l magnesium sulfate, 70 psi (4.8 bar) applied pressure, 77ºF (25ºC) feed water temperature and 15% recovery. Element permeate flow may vary -20%/+30%. Code: 090002
Housings 2,5'' for reverse osmosis membrane 1812, 2012 - 50, 75, 100, 150, 180GPD (25)
Variants Code
Description
090002-02 090002-04 090002-03 090002-05
Housings 2,5'' for reverse osmosis membrane 1812, 2012 double O-Ring thread-cap low pressure 1/8" (25) Housings 2,5'' for reverse osmosis membrane 1812, 2012 double O-Ring thread-cap high pressure 1/8" (24) 1812, 2012 Housing Wrench for cod. 090002-02 (Last Pieces) 1812, 2012 Housing Wrench for cod. 090002-02, 090002-04
With double o-ring.
19 June 2014
7/9
Code: 090009
Housings for reverse osmosis membrane 3012 - 300GPD (12)
Connections * Inlet/Outlet: 1/4"-3/8" * Drain: 1/4 " Code: 090011
Housings for reverse osmosis membrane 3012 - 300GPD Greenfilter (1)
Connections * Inlet/Outlet: 1/4"-3/8" * Drain: 1/4 "
19 June 2014
8/9