product catalogUE
Ground PV Mounting Systems Roof PV Mounting Systems Carport PV Mounting Systems
SolAR (PV) MOUNTING SYSTEMS
Solar Cube Mounting Systems Ltd Phone: 0121 555 1434 Fax: 0121 555 1435 (Ext 2455) Dartmouth Road Gaitskell Smethwick, B66 1BF UK
w w w. S OLARCU B E . c o m
2
3
s o l a r c u be . c o m
What we do We design and manufacture solar panel mounting systems for ground, roof and carport installations. Providing mounting solutions for utility-scale, commercial and industrial photovoltaic projects.
welcome
4 Ground
Mounting Systems
Solar Cube’s mounting systems are produced by The Hadley Group, Europe’s largest privately owned cold rolled steel manufacturer, combining deep expertise in steel manufacturing and specialized experience in Photovoltaic’s, empowering solar professionals and organizations with the intelligence and capabilities to respond to the rapidly evolving Solar market landscape. We hope you enjoy our product line up.
Panos Bi t archas
Panos Bitarchas, CEO, Solar Cube Mounting Systems Ltd.
8 CARPORT
Mounting Systems
10 ROOF
Mounting Systems
18 ABOUT
Our Process
4
5
s o l a r c u be . c o m
cr single pile GROUND SYSTEM
SINGLE PILE
DOUBLE PORTRAIT / LANDSCAPE GROUND MOUNTING SYSTEM Suitable for all framed Solar (PV) modules
Patented aluminiumclamp design
APPLICATION
GROUND MOUNTED
GROUNDING
Single pile ramming or drilling and concrete filling
SOIL CLASSES
Soil Classes 3-5 Soil Classes 5-7 (drilling)
MATERIAL
Cold roll-formed pre galvanized steel profiles according to EN 10147 – S320 + Z, or post galvanized steel profiles, Hot dip Galvanized piles IPE, RHS, Sigma or C section piles according to EN ISO 1461:2009
TILT ANGLES
Upon demand from 10º to 40º (degrees)
Norms & Standards Eurocode 1: Actions on structures (EC1, ENV 1991 1-1, 1--3, 1-4), - Part 1-1: General actions – Densities, self-weight and imposed loads
PANEL ARRANGEMENT
Double Portrait Quadruple Landscape
- Part 1-3: General actions – Snow loads - Part 1-4: General actions – Wind actions
MODULE COMPATIBILITY
Framed modules, all available commercial types
ACCESSORIES
Aluminum middle and end clamps: EN AW-6063 T66
CONNECTION TYPE
Grade 8.8 (galvanized) M12 and M8 (clamps) according to DIN933, 125, 9021, 985, 912 EPDM rubber against Electrolytic corrosion
WARRANTY
20 YEARS
Eurocode 3: Design of steel structures (EC3, ENV 1991-1-1, 1-3) - Part 1-1: General rules and rules for buildings - Part 1-3: General – Cold formed thin gauge members and sheeting - Part 1-8: General – Design of joints - Part 1-10: General – Material toughness and through thickness assessment
Eurocode 8: Design of structures for earthquake resistance (EC8, ENV 1998-1-1) Part 5: Foundations, retaining structures and geotechnical aspects Part 1: General rules, seismic actions and rules for buildings National Norms for Earthquake Resistance Other Regional Standards where Eurocodes not applicable.
WWW.SOLARCUBE.COM
6
7
s o l a r c u be . c o m
cr DOUBLE PILE GROUND SYSTEM
DOUBLE PILE
double portrait FOUR landscape GROUND MOUNTING SYSTEM Suitable for all framed Solar (PV) modules
Patented aluminium clamp design
APPLICATION
GROUND MOUNTED
GROUNDING
DOUBLE pile ramming or drilling and concrete filling
SOIL CLASSES
Soil Classes 3-5 Soil Classes 5-7 (drilling)
MATERIAL
Cold roll-formed pre galvanized steel profiles according to EN 10147 – S320 + Z, or post galvanized steel profiles, Hot dip Galvanized piles IPE, RHS, Sigma or C section piles according to EN ISO 1461:2009
TILT ANGLES
Upon demand from 10º to 40º (degrees)
Norms & Standards Eurocode 1: Actions on structures (EC1, ENV 1991 1-1, 1--3, 1-4), - Part 1-1: General actions – Densities, self-weight and imposed loads
PANEL ARRANGEMENT
Up to Triple Portrait Quadruple or more Landscape
- Part 1-3: General actions – Snow loads - Part 1-4: General actions – Wind actions
MODULE COMPATIBILITY
Framed modules, all available commercial types
ACCESSORIES
Aluminum middle and end clamps: EN AW-6063 T66
CONNECTION TYPE
Grade 8.8 (galvanized) M12 and M8 (clamps) according to DIN933, 125, 9021, 985, 912 EPDM rubber against Electrolytic corrosion
WARRANTY
20 YEARS
Eurocode 3: Design of steel structures (EC3, ENV 1991-1-1, 1-3) - Part 1-1: General rules and rules for buildings - Part 1-3: General – Cold formed thin gauge members and sheeting - Part 1-8: General – Design of joints - Part 1-10: General – Material toughness and through thickness assessment
Eurocode 8: Design of structures for earthquake resistance (EC8, ENV 1998-1-1) Part 5: Foundations, retaining structures and geotechnical aspects Part 1: General rules, seismic actions and rules for buildings National Norms for Earthquake Resistance Other Regional Standards where Eurocodes not applicable.
WWW.SOLARCUBE.COM
8
9
s o l a r c u be . c o m
cs a CARPORT SYSTEM
CS A
SOLAR (PV) CARPORT MOUNTING SYSTEM Suitable for all framed Solar (PV) modules
Patented aluminium clamp design
APPLICATION
Commercial and industrial parking areas
GROUNDING
Reinforced concrete foundations
SOIL CLASSES
Soil classes 3-7
MATERIAL
Cold roll-formed pre galvanized steel profiles according to EN 10147 – S320 + Z, or post galvanized steel profiles
TILT ANGLES
Upon demand from 7º to 10º (degrees)
PANEL ARRANGEMENT
Portrait 3x6 per double space unit
MODULE COMPATIBILITY
Framed modules, all available commercial types
ACCESSORIES
Aluminum middle and end clamps: EN AW-6063 T66
- Part 1-10: General – Material toughness and through thickness assessment
CONNECTION TYPE
Grade 8.8 (galvanized) M12 and M8 (clamps) according to DIN933, 125, 9021, 985, 912 EPDM rubber against Electrolytic corrosion
Eurocode 8:
WARRANTY
20 YEARS
Norms & Standards Eurocode 1: Actions on structures (EC1, ENV 1991 1-1, 1--3, 1-4), - Part 1-1: General actions – Densities, self-weight and imposed loads - Part 1-3: General actions – Snow loads - Part 1-4: General actions – Wind actions
Eurocode 3: Design of steel structures (EC3, ENV 1991-1-1, 1-3) - Part 1-1: General rules and rules for buildings - Part 1-3: General – Cold formed thin gauge members and sheeting - Part 1-8: General – Design of joints
Design of structures for earthquake resistance (EC8, ENV 1998-1-1) Part 5: Foundations, retaining structures and geotechnical aspects Part 1: General rules, seismic actions and rules for buildings National Norms for Earthquake Resistance Other Regional Standards where Eurocodes not applicable.
WWW.SOLARCUBE.COM
10
11
s o l a r c u be . c o m
cr SINGLE PILE / DOUBLE PORTRAIT
SINGLE PILE DOUBLE PORTRAIT STOCK GROUND MOUNTING SYSTEM Suitable for all framed Solar (PV) modules
Patented aluminium clamp design
APPLICATION
GROUND MOUNTED
GROUNDING
Single pile ramming or drilling and concrete filling
SOIL CLASSES
Soil Classes 3-5 Soil Classes 5-7 (drilling)
MATERIAL
Cold roll-formed pre galvanized steel profiles according to EN 10147 – S320 + Z, or post galvanized steel profiles, Hot dip Galvanized piles IPE, RHS, Sigma or C section piles according to EN ISO 1461:2009
TILT ANGLES
20º or 25º (degrees)
PANEL ARRANGEMENT
Double Portrait
MODULE COMPATIBILITY
Framed modules, all available commercial types
ACCESSORIES
Aluminum middle and end clamps: EN AW-6063 T66 Extension Kit
- Part 1-10: General – Material toughness and through thickness assessment
CONNECTION TYPE
Grade 8.8 (galvanized) M12 and M8 (clamps) according to DIN933, 125, 9021, 985, 912 EPDM rubber against Electrolytic corrosion
Eurocode 8:
WARRANTY
20 YEARS
Norms & Standards Eurocode 1: Actions on structures (EC1, ENV 1991 1-1, 1--3, 1-4), - Part 1-1: General actions – Densities, self-weight and imposed loads - Part 1-3: General actions – Snow loads - Part 1-4: General actions – Wind actions
Eurocode 3: Design of steel structures (EC3, ENV 1991-1-1, 1-3) - Part 1-1: General rules and rules for buildings - Part 1-3: General – Cold formed thin gauge members and sheeting - Part 1-8: General – Design of joints
Design of structures for earthquake resistance (EC8, ENV 1998-1-1) Part 5: Foundations, retaining structures and geotechnical aspects Part 1: General rules, seismic actions and rules for buildings National Norms for Earthquake Resistance Other Regional Standards where Eurocodes not applicable.
WWW.SOLARCUBE.COM
12
13
s o l a r c u be . c o m
cr SINGLE PILE / four LANDSCAPE
SINGLE PILE FOUR LANDSCAPE GROUND MOUNTING SYSTEM Suitable for all framed Solar (PV) modules
Patented aluminium clamp design
APPLICATION
GROUND MOUNTED
GROUNDING
Single pile ramming or drilling and concrete filling
SOIL CLASSES
Soil Classes 3-5 Soil Classes 5-7 (drilling)
Norms & Standards MATERIAL
Cold roll-formed pre galvanized steel profiles according to EN 10147 – S320 + Z, or post galvanized steel profiles, Hot dip Galvanized piles IPE, RHS, Sigma or C section piles according to EN ISO 1461:2009
TILT ANGLES
20º or 25º (degrees)
PANEL ARRANGEMENT
FOUR LANDSCAPE
MODULE COMPATIBILITY
Framed modules, all available commercial types
ACCESSORIES
Aluminum middle and end clamps: EN AW-6063 T66 Extension Kit
CONNECTION TYPE
Grade 8.8 (galvanized) M12 and M8 (clamps) according to DIN933, 125, 9021, 985, 912 EPDM rubber against Electrolytic corrosion
WARRANTY
20 YEARS
Eurocode 1: Actions on structures (EC1, ENV 1991 1-1, 1--3, 1-4), - Part 1-1: General actions – Densities, self-weight and imposed loads - Part 1-3: General actions – Snow loads - Part 1-4: General actions – Wind actions
Eurocode 3: Design of steel structures (EC3, ENV 1991-1-1, 1-3) - Part 1-1: General rules and rules for buildings - Part 1-3: General – Cold formed thin gauge members and sheeting - Part 1-8: General – Design of joints - Part 1-10: General – Material toughness and through thickness assessment
Eurocode 8: Design of structures for earthquake resistance (EC8, ENV 1998-1-1) Part 5: Foundations, retaining structures and geotechnical aspects Part 1: General rules, seismic actions and rules for buildings National Norms for Earthquake Resistance Other Regional Standards where Eurocodes not applicable.
WWW.SOLARCUBE.COM
14
15
s o l a r c u be . c o m
Ir iNDUSTRIAL ROOF SYSTEM APPLICATION
IR INDUSTRIAL ROOF MOUNTING SYSTEM Suitable for all framed Solar (PV) modules
Patented aluminium clamp design
Norms & Standards Eurocode 1: Actions on structures (EC1, ENV 1991 1-1, 1--3, 1-4),
Industrial roof and off-grid applications Chemical / Mechanical anchors (not included)
GROUNDING
N/A
SOIL CLASSES
N/A
MATERIAL
Cold roll-formed pre galvanized steel profiles according to EN 10147 – S320 + Z, or post galvanized steel profiles, Hot dip Galvanized piles IPE, RHS, Sigma or C section piles according to EN ISO 1461:2009
TILT ANGLES
10º to 35º (degrees) in 5º degrees per step
PANEL ARRANGEMENT
Single portrait Single landscape
- Part 1-1: General actions – Densities, self-weight and imposed loads - Part 1-3: General actions – Snow loads
MODULE COMPATIBILITY
Framed modules, all available commercial types
ACCESSORIES
Aluminum middle and end clamps: EN AW-6063 T66
- Part 1-10: General – Material toughness and through thickness assessment
CONNECTION TYPE
Grade 8.8 (galvanized) M12 and M8 (clamps) according to DIN933, 125, 9021, 985, 912 EPDM rubber against Electrolytic corrosion
Eurocode 8:
WARRANTY
20 YEARS
- Part 1-4: General actions – Wind actions
Eurocode 3: Design of steel structures (EC3, ENV 1991-1-1, 1-3) - Part 1-1: General rules and rules for buildings - Part 1-3: General – Cold formed thin gauge members and sheeting - Part 1-8: General – Design of joints
Design of structures for earthquake resistance (EC8, ENV 1998-1-1) Part 5: Foundations, retaining structures and geotechnical aspects Part 1: General rules, seismic actions and rules for buildings National Norms for Earthquake Resistance Other Regional Standards where Eurocodes not applicable.
WWW.SOLARCUBE.COM
16
17
s o l a r c u be . c o m
Fr fLAT ROOF SYSTEM
FR FLAT ROOF MOUNTING SYSTEM Suitable for all framed Solar (PV) modules
Patented aluminium clamp design
APPLICATION
Flat roof, small to utility scale installations
GROUNDING
Concrete counterweights
SOIL CLASSES
N/A
Norms & Standards MATERIAL
Cold roll-formed pre galvanized steel profiles according to EN 10147 – S320 + Z, or post galvanized steel profiles, Hot dip Galvanized piles IPE, RHS, Sigma or C section piles according to EN ISO 1461:2009
TILT ANGLES
Upon demand from 10º to 30º (degrees)
Eurocode 1: Actions on structures (EC1, ENV 1991 1-1, 1--3, 1-4), - Part 1-1: General actions – Densities, self-weight and imposed loads - Part 1-3: General actions – Snow loads - Part 1-4: General actions – Wind actions
PANEL ARRANGEMENT Eurocode 3:
single landscape or single PORTRAIT
Design of steel structures (EC3, ENV 1991-1-1, 1-3) - Part 1-1: General rules and rules for buildings
MODULE COMPATIBILITY
Framed modules, all available commercial types
ACCESSORIES
Aluminum middle and end clamps: EN AW-6063 T66
CONNECTION TYPE
Grade 8.8 (galvanized) M12 and M8 (clamps) according to DIN933, 125, 9021, 985, 912 EPDM rubber against Electrolytic corrosion
WARRANTY
20 YEARS
- Part 1-3: General – Cold formed thin gauge members and sheeting - Part 1-8: General – Design of joints - Part 1-10: General – Material toughness and through thickness assessment
Eurocode 8: Design of structures for earthquake resistance (EC8, ENV 1998-1-1) Part 5: Foundations, retaining structures and geotechnical aspects Part 1: General rules, seismic actions and rules for buildings National Norms for Earthquake Resistance Other Regional Standards where Eurocodes not applicable.
WWW.SOLARCUBE.COM
18
19
s o l a r c u be . c o m
Our process Our technical skills, experience and management strategies simplify the process.
ABOUT US
We have the know-how to maximize your photovoltaic project potentials.
Analysis
Design
Production
Supply
Solar Cube Mounting Systems Ltd is an experienced designer and producer of Photovoltaic (PV) Panel Mounting Systems engineered for Utility-Scale, Industrial and Commercial Developments.
Analysis
Design
The client / developer data allows our team to examine
Our experienced engineering teams design the mounting
and analyze the location data, from soil reports to satellite
system according to data specifications and provide drawings
imagery and determine the approriate mounting system
and calculations for usage by installation teams and
specifications to maximize efficiency and value.
developer engineers.
Manufacturing
Implementation
Solar Cube’s mounting systems are produced by the Hadley
Solar Cube follows the installation and assists project
Group, Europe’s largest privately owned cold rolled steel
collaborators and end-clients to ensure efficient deployment
manufacturer, offering manufacturing capacity, reliable
and assembly training with intuitive user guides and
solutions and undisputed know-how.
personalized advice and troubleshooting.
The company operates locations in the United Kingdom, United States and Asia, offering mounting system design, logistics, supply & installation support.
Visit us online at www.solarcube.com
solar cube mounting systems ltd
Dartmouth Road Gaitskell Smethwick, B66 1BF Phone: 0121 555 1434 Fax: 0121 555 1435 (Ext 2455) Email: contact@solarcube.com
UNITED STATES
INDIA
Solar Cube LLC
Solar Cube India Pvt Ltd
991 US Hwy 22W Bridgewater New Jersey 08807
M-9, 2nd Floor Lajpat Nagar-2 New Delhi , 110024
Phone: (+1) 888 966-9055 Fax: (+1) 855 880-5016
Phone: +91 11 4969 9912 Fax: +91 84 477 44619
Visit us Online www.solarcube.com