Rsg2300 c datasheet

Page 1

GIGABIT A Siemens Business

eRSTP

RoS GIGABIT RuggedSwitch RSG2300 eRSTP RoS ®

TM

TM

32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports, 128-bit Encryption

eRSTP

TM

ZPL

ZPL eRSTP

Zero-Packet-Loss™

eRSTP

ZPL

TM

Rugged Operating System™

Zero-Packet-Loss™ Rugged Operating System™

ZPL eRSTP

eRSTP

Zero-Packet-Loss™

Rugged Operating System™

TM

Zero-Packet-Loss™

TM

Rugged Operating System™

Rugged Operating System™

eRSTP

Rugged Operating System™

TM

ZPL

TM

ZPL

The RuggedSwitch® RSG2300 is an industrially hardened, fully RuggedRated™ for Reliability in Harsh Environments managed, modular, Ethernet switch specifically designed to Immunity to EMI and heavy electrical surges yy operate reliably in electrically harsh and climatically demanding Zero-Packet-Loss™ Technology yy utility substation and industrial environments. The RSG2300’s Zero-Packet-Loss™ Zero-Packet-Loss™ Meets IEEE 1613 Class 2 (electric utility substations) yy superior ruggedized hardware design coupled with the Exceeds IEC 61850-3 (electric utility substations) yy embedded Rugged Operating System (ROS®) provides improved Exceeds IEC 61800-3 (variable speed drive systems)TM yy system reliability and advanced cyber security and networking Exceeds IEC 61000-6-2 (generic industrial) yy features making it ideally suited for creating secure Ethernet Exceeds NEMA TS-2 (traffic control equipment) networks for mission-critical, real-time, control applications. -40° to +85°C operating temperature (no fans) Conformal coated printed circuit boards (optional) The RSG2300’s modular flexibility offers 10BaseFL /100BaseFX 18 AWG galvanized steel enclosure /1000BaseX fiber and 10/100/1000BaseTX copper port Hazardous Location Certification: Class 1 Division 2 combinations. Optional front or rear mount connectors make the Rugged Operating System (ROS®) Features RSG2300 highly versatile for any application and can support Simple plug and play operation - automatic learning, multiple fiber connectors (ST, MTRJ, LC, SC) without loss of port negotiation, and crossover detection density. The RSG2300 is packaged in a rugged galvanized steel MSTP 802.1Q-2005 (formerly 802.1s) enclosure with industrial grade DIN, panel, or 19” rack-mount RSTP (802.1w) and Enhanced Rapid Spanning Tree mounting options. (eRSTP™) network fault recovery (<5ms) Quality of Service (802.1p) for real-time traffic Features and Benefits VLAN (802.1Q) with double tagging and GVRP support Link aggregation (802.3ad) Ethernet Ports IGMP Snooping for multicast filtering 24 10/100TX copper ports Port Rate Limiting and Broadcast Storm Limiting Optional: up to 4 1000LX Gigabit Ethernet ports (copper and/ Port configuration, status, statistics, mirroring, security or fiber) and up to 8 100FX Fiber Fast Ethernet ports yy SNTP time synchronization (client and server) 2 port modules for tremendous flexibility Industrial automation features (eg. Modbus) Non-blocking, store and forward switching Supports many types of fiber (Multimode, singlemode, Management Tools bi-directional single strand) Web-based, Telnet, CLI management interfaces Long haul optics allow distances up to 90km SNMP v1/v2/v3 (56-bit encryption) Multiple connector types (ST, MTRJ, LC, SC) Remote Monitoring (RMON)

Cyber Security Features

Multi-level user passwords SSH/SSL with 128-bit encryption Enable/disable ports, MAC based port security Port based network access control (802.1x) VLAN (802.1Q) to segregate and secure network traffic RADIUS centralized password management SNMPv3 authentication and 56-bit encryption

eRSTP

Rich set of diagnostics with logging and alarms

Universal Power Supply Options

Fully integrated, dual-redundant (optional) power supplies Universal high voltage range: 88-300VDC or 85-264VAC Popular low voltage ranges: 2 4VDC(12-36VDC), 48VDC (36-59VDC) Screw or pluggable terminal blocks available Terminal blocks for reliable maintenance free connections CSA/UL 60950 safety approved to +85°C

RUGGEDCOM

ISO 9001 REGISTERED

www.RuggedCom.com

RuggedSwitch® RSG2300

1


RuggedSwitch® RSG2300

A Siemens Business

32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports, 128-bit Encryption

RuggedSwitch® RSG2300 Modular Gigabit Port Types: Modularity: Modular Fast Ethernet Port Types: XX up to 4 Gigabit modular Ports XX4 available slots XX up to 8 Fast Ethernet modular Ports XX 10/100/1000 TX RJ45 XX Up to 4 Modular Gigabit ports XX 10/100TX RJ45 XX 1000SX Multimode XXUp to 8 modular Fast Ethernet ports XX 100FX Multimode &Singlemode XX 1000LX Singlemode XX Dual and single port modules XX SC, ST, LC and MTRJ XX Pluggable Optics (SFP and GBIC) XX SC, ST, LC and MTRJ

Mounting Options XX Panel/Din Rail XX 19” Rack Mount XX Front or Rear Mount

Integrated Power Supply XX Universal high-voltage range: 88-300VDC or 85-264VAC XX Popular low voltage DC ranges: 24VDC (12-36VDC), 48VDC (36-59VDC) XX True Dual Redundant Parallel Load Sharing (Optional) XX Screw or pluggable terminal blocks available

www.RuggedCom.com

Standard Fast Ethernet Ports Types: XX24 10/100TX Copper Ethernet Ports

Operating Temperature XX - 40°C to +85°C XX No Fans

Modular HMI: XXFront or Rear Mount

Critical Alarm Relay XX Form-C contact ratings: Max Voltage 250VAC,125VDC Max Current 2A@250VAC, 2A@30VDC

RuggedSwitch® RSG2300

2


RuggedSwitch® RSG2300

A Siemens Business

32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports, 128-bit Encryption

ROS® Features Cyber Security

Cyber security is an urgent issue in many industries where advanced automation and communications networks play a crucial role in mission critical applications and where high reliability is of paramount importance. Key ROS® features that address security issues at the local area network level include: Passwords - Multi-level user passwords secures switch against unauthorized configuration SSH / SSL - Extends capability of password protection to add 128-bit encryption of passwords and data as they cross the network Enable/Disable Ports - Capability to disable ports so that traffic can not pass 802.1Q VLAN - Provides the ability to logically segregate traffic between predefined ports on switches MAC Based Port Security - The ability to secure ports on a switch so only specific Devices / MAC addresses can communicate via that port 802.1x Port Based Network Access Control - The ability to lock down ports on a switch so that only authorized clients can communicate via this port R ADIUS - authentication service using MD5 hash and providing centralized password management SNMPv3 - encrypted authentication access security and data encryption (CBC-DES with 56-bit encryption key) Secure Socket Layer - Web-based management using SSL with data encryption (128-bit encryption key) RSA – 1024 bit key for key management and key exchange TACACS+ - Terminal Access Control and Accounting Services Client provides encrypted authentication and authorization Point to Point (PPP) - using CHAP (MD5 Hash) authentication service SFTP - Secure File Transfer Protocol using SSH encryption

The ROS® cyber security features are included to help address the various industry specific security standards such as NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 and PCSRF SPP-ICS.

Enhanced Rapid Spanning Tree Protocol (eRSTP™)

RuggedCom eRSTP™ allows the creation of fault-tolerant ring and mesh Ethernet networks that incorporate redundant links that are ‘pruned’ to prevent loops. eRSTP™ yields worst-case fault recovery1 of 5ms times the ‘bridge diameter’ and allows rings of up to 160 switches. For example, a ring of ten switches will have fault recovery times under 50ms. eRSTP™ implements both STP and RSTP to ensure interoperability with commercial switches unlike other proprietary ‘ring’ solutions.

Quality of Service (IEEE 802.1p)

Some networking applications such as real-time control or VoIP (voice over IP) require predictable arrival times for Ethernet frames. Switches can introduce latency in times of heavy network

www.RuggedCom.com

traffic due to the internal queues that buffer frames and then transmit on a first come first serve basis. ROS® supports ‘Class of Service’ in accordance with IEEE 802.1p that allows time critical traffic to jump ahead to the front of the queue thus minimizing latency and reducing jitter to allow such demanding applications to operate correctly. ROS® allows priority classification by port, tags, MAC address, and IP type of service (ToS). A configurable “weighted fair queuing” algorithm controls how frames are emptied from the queues.

VLAN (IEEE 802.1Q)

Virtual local area networks (VLAN) allow the segregation of a physical network into separate logical networks with independent broadcast domains. A measure of security is provided since hosts can only access other hosts on the same VLAN and traffic storms are isolated. ROS® supports 802.1Q tagged Ethernet frames and VLAN trunks. Port based classification allows legacy devices to be assigned to the correct VLAN. GVRP support is also provided to simplify the configuration of the switches on the VLAN.

Link Aggregation (802.3ad)

The link aggregation feature provides the ability to aggregate several Ethernet ports into one logical link (port trunk) with higher bandwidth. This provides an inexpensive way to set up a high speed backbone to improve network bandwidth. This feature is also known as “port trunking”, “port bundling”, “port teaming”, and “Ethernet trunk”.

IGMP Snooping

ROS® uses IGMP snooping (Internet Group Management Protocol v1&v2) to intelligently forward or filter multicast traffic streams (e.g. MPEG video) to or from hosts on the network. This reduces the load on network trunks and prevents packets from being received on hosts that are not involved. ROS® has a very powerful implementation of IGMP snooping that: Can be enabled on a per VLAN basis. Detects and filters all multicast streams regardless of whether subscribers exist. Supports “router-less” operation by supporting an “active” mode. Restores traffic streams immediately after an RSTP topology change.

SNMP (Simple Network Management Protocol)

SNMP provides a standardized method for network management stations the ability to interrogate devices from different vendors. SNMPv3 in particular provides security features such as authentication, privacy with data encryption (CBC-DES with 56-bit encryption key) and access control not present in earlier SNMP versions. ROS® also supports numerous standard MIBs (Management Information Base) allowing for easy integration with any network management system (NMS).

RuggedSwitch® RSG2300

3


RuggedSwitch® RSG2300

A Siemens Business

32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports, 128-bit Encryption

ROS® Features A feature of SNMP supported by ROS® is the ability to generate “traps” upon system events. RuggedNMSTM, the RuggedCom management solution, can record traps from multiple devices providing a powerful network troubleshooting tool. It also provides a graphical visualization of the network and is fully integrated with all RuggedCom products.

Port Mirroring

1 eRSTP™ f ault recovery times may be approximated as follows:

ROS® allows individual ports to be ‘hard’ configured for speed, duplex, auto-negotiation, flow control and more. This allows proper connection with devices that do not negotiate or have unusual settings. Detailed status of ports with alarm and SNMP trap on link problems aid greatly in system troubleshooting.

For 100 Mbps, fault recovery performance is <5ms/hop

For 1,000 Mbps, fault recovery performance is <5ms/hop + 20ms

SNTP (Simple Network Time Protocol)

SNTP automatically synchronizes the internal clock of all ROS® devices on the network. This allows for correlation of time stamped events for troubleshooting.

SCADA and Industrial Automation

ROS® contains features that optimize network performance and simplify switch management based on the unique requirements found in SCADA and industrial automation applications. Features such as Modbus TCP management for retrieval of switch data using the ubiquitous Modbus protocol and DHCP Option 82, a Rockwell Automation ODVA requirement for IP address assignment based on the location of the end device, provide capabilities not found in typical “commercial” or “office grade” Ethernet switches.

Port Based Network Access Control (802.1x)

ROS® supports the IEEE 802.1x standard that defines a mechanism for port-based network access control which provides a means of authenticating and authorizing devices attached to LAN ports.

ROS® can be configured to duplicate all traffic on one port to a designated mirror port. When combined with a network analyzer, this can be a powerful troubleshooting tool.

Port Configuration and Status

Port Statistics and RMON (Remote Monitoring)

ROS® provides continuously updating statistics per port that provide both ingress and egress packet and byte counters as well as detailed error figures. Also provided is full support for the RMON statistics, history, alarms, and event groups. RMON allows for very sophisticated data collection, analysis and detection of traffic patterns.

Event Logging and Alarms

ROS® records all significant events to a non-volatile system log allowing forensic troubleshooting. Events include link failure and recovery, unauthorized access, broadcast storm detection, and self-test diagnostics among others. Alarms provide a snapshot of recent events that have yet to be acknowledged by the network administrator. An external hardware relay is de-energized during the presence of critical alarms allowing an external controller to react if desired.

HTML Web Browser and Telnet User Interfaces

ROS® supports configurable rate limiting per port to limit unicast and multicast traffic. This can be essential to managing precious network bandwidth for service providers. It also provides edge security for denial of service (DoS) attacks.

ROS® provides a simple, intuitive user interface for configuration and monitoring via a standard graphical web browser or via Telnet. All system parameters include detailed on-line help to make setup a breeze. ROS®, presents a common look and feel and standardized configuration process allowing easy migration to other RuggedCom managed products.

Broadcast Storm Filtering

Configuration via ASCII Text File

Port Rate Limiting

Broadcast storms wreak havoc on a network and can cause attached devices to malfunction. This could be disastrous on a network with mission critical equipment. ROS ® limits this by filtering broadcast frames with a user-defined threshold.

Loss of Link Management

Some intelligent electronic devices (IEDs) have dual fiber optic ports with automatic failover to a backup port should the primary fail. ROS ® ensures this mechanism works reliably under all failure modes by appropriately disabling link signals when required. ROS ® also flushes learned MAC addresses to ensure the failover occurs quickly.

www.RuggedCom.com

All configuration parameters are stored in an ASCII formatted text file that can easily be transferred via TFTP or Xmodem. The configuration file can be saved for backup purposes and easily manipulated by a text editor. The same text file can be downloaded to the switch at a later date in order to re-configure or restore a previous configuration.

Command Line Interface (CLI)

A command line interface can be used in conjunction with remote shell to automate data retrieval, configuration updates, and firmware upgrades. A powerful SQL-like capability allows expert users the ability to selectively retrieve or manipulate any parameters the device has to offer.

RuggedSwitch® RSG2300

4


RuggedSwitch® RSG2300

A Siemens Business

32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports, 128-bit Encryption

EMI and Environmental Type Tests IEC 61850-3 EMI TYPE TESTS TEST

Description

IEC 61000-4-2

ESD

IEC 61000-4-3

Radiated RFI

Test Levels Enclosure Contact Enclosure Air Enclosure ports Signal ports

IEC 61000-4-4

+/- 4kV @ 2.5kHz

x

+/- 4kV

4

+/- 4kV

4

+/- 4kV

4

+/- 4kV line-to-earth, +/- 2kV line-to-line +/- 2kV line-to-earth, +/- 1kV line-to-line +/- 4kV line-to-earth, +/- 2kV line-to-line

4 3 4

Signal ports

10V

3

D.C Power ports

10V

3

A.C. Power ports

10V

3

D.C. Power ports

Burst (Fast Transient)

A.C. Power ports Earth ground ports

IEC 61000-4-5

IEC 61000-4-6

Induced (Conducted) RFI

Earth ground ports IEC 61000-4-8 IEC 61000-4-29

Magnetic Field

1

Enclosure ports D.C. Power ports

Voltage Dips & Interrupts

A.C. Power ports

IEC 61000-4-11 IEC 61000-4-12

1

Signal ports D.C. Power ports A.C. Power ports

Surge

Signal ports D.C. Power ports A.C. Power ports Signal ports D.C. Power ports D.C. Power ports Signal ports D.C. Power ports A.C. Power ports Signal ports D.C. Power ports A.C. Power ports

Damped Oscillatory

IEC 61000-4-16

Mains Frequency Voltage

IEC 61000-4-17

Ripple on D.C. Power Supply

IEC 60255-5

Dielectric Strength

IEC 60255-5

H.V. Impulse

Severity Levels 4 4 x

+/- 8kV +/- 15kV 20 V/m

10V

3

40 A/m continuous, 1000 A/m for 1 s

N/A

30% for 0.1s, 60% for 0.1s, 100% for 0.05s

N/A

30% for 1 period, 60% for 50 periods

N/A

100% for 5 periods, 100% for 50 periods

N/A

2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 30V Continuous, 300V for 1s 30V Continuous, 300V for 1s 10% 2kVac (Fail-Safe Relay output) 1.5kV DC 2kVac 5kV (Fail-Safe Relay output) 5kV 5kV

3 3 3 4 4 3 N/A N/A N/A N/A N/A N/A

IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS Test

Description

IEEE C37.90.3

ESD

IEEE C37.90.2

Radiated RFI

IEEE C37.90.1

Fast Transient

IEEE C37.90.1

Oscillatory

IEEE C37.90

H.V. Impulse

IEEE C37.90

Dielectric Strength

Enclosure Contact Enclosure Air Enclosure ports Signal ports D.C. Power ports A.C. Power ports Earth ground ports1 Signal ports D.C. Power ports A.C. Power ports Signal ports D.C. Power ports A.C. Power ports Signal ports D.C. Power ports A.C. Power ports

Test Levels +/- 8kV +/- 15kV 35 V/m +/- 4kV @ 2.5kHz +/- 4kV +/- 4kV +/- 4kV 2.5kV common mode @1MHz 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 5kV (Fail-Safe Relay output) 5kV 5kV 2kVac 1.5kV DC 2kVac

Severity Levels N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Environmental Type Tests Test IEC 60068-2-1

Description Cold Temperature

Test Ad

Test Levels -40°C, 16 Hours

Severity Levels N/A

IEC 60068-2-2

Dry Heat

Test Bd

+85°C, 16 Hours

N/A N/A Class 2 Class 2

IEC 60068-2-30

Humidity (Damp Heat, Cyclic)

Test Db

95% (non-condensing), 55°C , 6 cycles

IEC 60255-21-1 IEC 60255-21-2

Vibration Shock

Tests Fc Tests Ea

2g @ (10 - 150) Hz 30g @ 11mS

2 2

Notes:

1. Only applicable to functional earth connections separated from the safety earth connection.

2. Class 2 refers to “Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high,( e.g. shipboard application and for severe transportation conditions”)

www.RuggedCom.com

RuggedSwitch® RSG2300

5


RuggedSwitch® RSG2300

A Siemens Business

32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports, 128-bit Encryption

Technical Specifications Power Supply

Power Consumption: 32W Max 24VDC: 12-36 VDC, 1.2A 48VDC: 36-59 VDC, 0.6A HI Voltage AC/DC: 88-300VDC or 85-264VAC

Critical Alarm Relay

Form-C contact ratings: yy Max Voltage 250VAC,125VDC yy Max Current 2A@250VAC, 2A@30VDC

Physical

Height: 1.74” Width: 18.3” Depth: 12.4” Weight: 5.2kg Ingress Protection: IP40 (1mm objects) Enclosure: 18 AWG galvanized steel enclosure Mounting: DIN rail or panel mounted

Switch Properties

Switching method: Store & Forward Switching latency: 7 us Switching bandwidth: 13.6 Gbps MAC addresses: 8192 MAC address table size: 64kbytes Priority Queues: 4 Frame buffer memory: 2 Mbit Simultaneous VLANs: 255 VLAN ID Range: 1 to 4094 IGMP multicast groups: 256 Port rate limiting No head of line blocking

Approvals

ISO: Designed and manufactured using a ISO9001: 2000 certified quality program CE Marking Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A) Safety: cCSAus (Compliant with CSA C22.2 No. 60950, UL 60950, EN60950) Laser Eye Safety (FDA/CDRH): Complies with 21 CFR Chapter1, Subchapter J. HazLoc Class 1, Div 2

Network Management

HTTP graphical web-based, SSL (128-bit encryption) SNMP v1, v2c, v3 (56-bit encryption) Telnet, VT100, SSH/SFTP (128-bit encryption) Command Line Interface (CLI) RSA Key Management (1024 bit key) Authentication and Accounting - TACACS+ (encrypted), RADIUS client, PPP

www.RuggedCom.com

Warranty

5 Years - Applicable to design and manufacturing related product defects.

EMI Immunity and Environmental Compliance IEC 61000-6-2 Industrial (Generic) IEC 61800-3 Industrial (Variable Speed Drive Systems) IEC 61850-3 Electric Utility Substations IEEE 1613 Electric Utility Substations NEMA TS 2 Traffic Control Equipment

IEEE Compliance

802.3-10BaseT 802.3u-100BaseTX, 100BaseFX 802.3x-Flow Control 802.3z-1000BaseLX 802.3ab-1000BaseTX 802.3ad-Link Aggregation 802.1D-MAC Bridges 802.1D-Spanning Tree Protocol 802.1p-Class of Service 802.1Q-VLAN Tagging 802.1w-Rapid Spanning Tree Protocol 802.1x-Port Based Network Access Control 802.1Q-2005 (formerly 802.1s) MSTP

IETF RFC Compliance

RFC768-UDP RFC783-TFTP RFC791-IP RFC792-ICMP RFC793-TCP RFC826-ARP RFC854-Telnet RFC894-IP over Ethernet RFC1112-IGMP v1 RFC1519-CIDR RFC1541-DHCP (client) RFC2030-SNTP RFC2068-HTTP RFC2236-IGMP v2 RFC2284-EAP RFC2475-Differentiated Services RFC2865-RADIUS RFC3414-SNMPv3-USM RFC3415-SNMPv3-VACM

IETF SNMP MIBS

RFC1493-BRIDGE-MIB RFC1907-SNMPv2-MIB RFC2012-TCP-MIB RFC2013-UDP-MIB RFC2578-SNMPv2-SMI RFC2579-SNMPv2-TC RFC2819-RMON-MIB RFC2863-IF-MIB draft-ietf-bridge-rstpmib-03-BRIDGE-MIB draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB IANAifType-MIB

RuggedSwitch® RSG2300

6


RuggedSwitch速 RSG2300

A Siemens Business

32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports, 128-bit Encryption

Dimensions

www.RuggedCom.com

RuggedSwitch速 RSG2300

7


RuggedSwitch® RSG2300

A Siemens Business

32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports, 128-bit Encryption

Order Codes RSG2300  - ______ - ______ - ____ - ____ - ____ - ____ - ____ - ____ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 MOD

Main: Ethernet and Power Connectors

R = Ethernet on rear; LED panel on front; power connector on rear F=E thernet on front; LED panel on front; power connector on rear B = Ethernet on rear; LED panel on top; power connector on rear T = Ethernet on front; LED panel on top; power connector on rear

Mount: Mounting Options

RM = 19” Rack Mount Kit DP = DIN and Panel Mount Kit RD = 19” Rack, DIN, and Panel Mount Kit 00 = No Mounting Option

PS1 and PS2: Power Supply 1 and 26

24 = 24VDC (12-36VDC), screw terminal block 48 = 48VDC (36-59VDC), screw terminal block HI = 88-300VDC or 85-265VAC, screw terminal block 24P = 24VDC (12-36VDC), pluggable terminal block 48P = 48VDC (36-59VDC), pluggable terminal block HIP = 88-300VDC or 85-265VAC, pluggable terminal block XX = No Power Supply (PS2 Only)

S1, and S2: Ethernet Modules for Slots 1 and 2

XXXX = Empty TX01 = 2 x 10/100Tx RJ45 FL01 = 2 x 10FL - Multimode, 850nm, ST FX01 = 2 x 100FX - Multimode, 1300nm, ST FX02 = 2 x 100FX - Multimode, 1300nm, SC FX11 = 2 x 100FX – Multimode, 1300nm, LC FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ FX04 = 2 x 100FX - Singlemode, 1310nm, ST, 20km FX05 = 2 x 100FX - Singlemode, 1310nm, SC, 20km FX06 = 2 x 100FX - Singlemode, 1310nm, LC, 20km FX07 = 2 x 100FX - Singlemode, 1310nm, SC, 50km FX08 = 2 x 100FX - Singlemode, 1310nm, LC, 50km FX09 = 2 x 100FX - Singlemode, 1310nm, SC, 90km FX10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km

FG51 = 2 x 1000SX SFP - Multimode, 850nm, LC, 500m (4) FG52 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 10km (4) FG53 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 25km (4) FG54 = 2 x 1000LX SFP - Singlemode, 1550nm, LC, 70km (2) (4) FG70 = 2 x 1000LX GBIC - Blank (no optical transceiver) FG71 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km (5) FG72 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km (5) FG73 = 2 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km(2) (5) FXA01 = 2 x 100FX - Multimode, 1300nm, ST FXA02 = 2 x 100FX - Multimode, 1300nm, SC FXA11 = 2 x 100FX – Multimode, 1300nm, LC FXA03 = 2 x 100FX - Multimode, 1300nm, MTRJ FXA04 = 2 x 100FX - Singlemode, 1310nm, ST, 20km FXA05 = 2 x 100FX - Singlemode, 1310nm, SC, 20km FXA06 = 2 x 100FX - Singlemode, 1310nm, LC, 20km FXA07 = 2 x 100FX - Singlemode, 1310nm, SC, 50km FXA08 = 2 x 100FX - Singlemode, 1310nm, LC, 50km FXA09 = 2 x 100FX - Singlemode, 1310nm, SC, 90km FXA10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km

MOD: Manufacturing Modifications XX = None C01 = Conformal Coating Notes: 1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices. 2 These transceivers have an operating temperature range of -20 °C to +85°C. All other transceivers have an operating temperature range of -40°C to +85°C 3 Base unit comes standard with 24 10/100TX RJ45 ports 4 SFP plugable optics that consist of a blank cage (FG50 for dual, 1FG50 for single) plus specified fiber optic interface(s) installed 5 GBIC plugable optics that consist of a blank cage (FG70 for dual, 1FG70 for single) plus specified fiber optic interface(s) installed 6 Power Supply 1 and 2 must be either both screw terminal block or both pluggable terminal block

S3 and S4: 100FX/Gigabit Ethernet Modules for Slots 3 and 4

XXXX = Empty CG01 = 2 x 10/100/1000Tx RJ45 FG01 = 2 x 1000SX - Multimode, 850nm, LC, 500m FG02 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 10km FG03 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 10km FG04 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 25km FG05 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km FG50 = 2 x 1000LX SFP - Blank (no optical transceiver)

www.RuggedCom.com

RuggedSwitch® RSG2300

8


RuggedSwitch® RSG2300

A Siemens Business

32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports, 128-bit Encryption

Example Order Codes: RSG2300-R-RM-24-48-TX01-TX01-XXXX-XXXX-XX 19” Rack mounted, 24VDC power supply, 48VDC power supply, 28 10/100 RJ45 Ethernet Ports, with Ethernet ports on the rear. RSG2300-F-RM-48-48-TX01-TX01-FXA01-FXA01-XX 19” Rack mounted, 48VDC power supply, 48VDC, 28 10/100 RJ45 Ethernet Ports, 4 100FX (Multi Mode 1300nm Fiber) Ethernet ports, with Ethernet ports on the front. RSG2300-R-RM-HI-HI-TX01-TX01-FG02-FG02-C01 19” Rack mounted, HI power supply, HI power supply, 28 10/100 RJ45 Ethernet Ports, 4 1000LX (Gigabit) Ethernet ports, with Ethernet ports on the rear, conformal coating. Accessories/Options 41-11-0011 - Cable support bracket (one) 43-10-0007 - Power cable (North America three prong connector -> beau)

www.RuggedCom.com

RuggedSwitch® RSG2300

9


RuggedSwitch® RSG2300

A Siemens Business

32-Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports, 128-bit Encryption

RuggedCom Inc.

300 Applewood Crescent, Concord, Ontario, Canada  L4K 5C7 Tel:  +1 (905) 856-5288  Fax:  +1 (905) 856-1995 Toll Free:  1 (888) 264-0006

Technical Support Center

Toll Free (USA & Canada):  1 (866) 922-7975 International:  +1 (905) 856-5288 USA:  +1 (954) 922-7975 E-mail: Support@RuggedCom.com © 2011 RuggedCom Inc. RuggedSwitch is a registered trademark of RuggedCom Inc. Ethernet is a trademark of the Xerox Corporation. Patent Pending All specifications in this document are subject to change without notice. Rev 1r — 06/07/12

www.RuggedCom.com

For additional information on our products and services, please visit our web site at: www.RuggedCom.com

RuggedSwitch® RSG2300

10


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.