http://www.sourceav.com/Files/Commend/Data_Sheets_Networking_-_SIP/DS-G7-WAN-CU-EN-V10-1207

Page 1

DATASHEET

G7-WAN-8 G7-WAN-16

3

1

IP-Network Card G7-WAN Intercom Servers with a WAN card act as a network node, like a gateway in the Internet. Now, this gateway can be used to link up to 120 ‘regions’. A region is defined as a complete, integrated, local Intercom network. These networks have a uniform 4-digit dialling code system with no

1.

G7-WAN-8 IP-Network card for Intercom Servers for supra-regional networking. Up to 8 Intercom Servers can be addressed directly. Up to 8 conversations with 7 kHz, 16 conversations with 3.5 kHz, music programmes or radio channels can be accessed simultaneously with the maximum bandwidth. Each of these connections can be defined as a regional connection (LAN with full range of features, also to G7-CNET-LAN) or a multi-regional connection (WAN with limited range of features).

2.

G7-WAN-16 (not pictured) Same as G7-WAN-8 however with 16 connections per card (maximum 8 conversations with 7 kHz, 16 conversations with 3.5 kHz simultaneously).

limitation of features. In order to interconnect the regions, in the supra-regional Intercom network they are assigned 1- to 4-digit prefix codes. In this way, up to 30,000 subscribers are able to communicate directly with each other.

3.

GEA-WAN Installation board for the G7-WAN network card with shielded RJ 45 connectors and status LEDs, for use in a GE 700 or in the interface housing GEI 200 (required for GE 200).

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 1.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.

www.commend.com

P1|5


DATASHEET

G7-WAN

Technische Daten – Benefits TECHNICAL DATA

BENEFITS

Operating temperature range: 0° C to +50° C (32° F to 122° F)

• Intercom system divided into regions

Storage temperature range: –30° C to +60° C (–22° F to 140° F)

• WAN networking over IP with up to 120 regions

Relative Humidity:

20 % to 80 %

Plug: Card: 96-way PC board connector according to DIN 41612 Ethernet: 2 x RJ 45, Cabling: 10/100Base-T Connection GEV-Ring: 2 x RJ 45 Power supply:

from central

Emergency power consumption:

0.05 Ah/h

• Can be used to configure Intercom systems with up to 14,280 networked Intercom Servers • Up to 30,000 subscribers are able to communicate with each other within the entire WAN network • Maintenance and configuration of the entire network from one central point

Number of connections between two centrals: G7-WAN-8: 8 two centrals / regions: G7-WAN-16: 16

• Regions with 4-digit numbering system

Number of possible conversations per card:

• 1- to 4-digit prefix codes to identify different regions

Cabling:

8 (7 kHz) 16 (3.5 kHz)

• Full-feature regional operation

CAT 5

Protocol:

IoIP® protocol (over UDP) + IP protocol

Ethernet:

2 x 10/100 MBit/s (full / half duplex)

Maximum acceptable packet delay: Measurements:

100 ms

100 x 167 mm (3.94 x 6.58 inch)

Weight including package:

373 g (0.8 lbs)

• Supra-regional operation with limited features • Integrated Switch

SYSTEM OVERVIEW Example of a “complete network”:

SYSTEM REQUIREMENTS Please also pay special attention to the requirements of the Network on page 3! • Central Software min. Pro 06.0 build 14

G7-WAN

WAN WAN

G7-WAN

• Configuration software CCT 6.0 build 9 G7-WAN

• For centrals GE 200 an interface housing GEI 200 is required. The G7-WAN-16 card is not supported in the GE 200 (only 2 G7-WAN-8 can be used). For all network cards in the same central as the G7-WAN the following hard- and software versions are required: • G7-GEV: software min. 5.1 build 2 and hardware min. 3.0 • G7-CNET-W and G7-CNET-E1: software min. 5.1 build 2 and hardware min. 2.0 For connections via WAN the entire conversation/call path must contain network cards with software min. 5.1 build 2 and central software min Pro 06.0.

SPEECH CHANNELS The maximum number of conversations depends on the following factors: • The available bandwidth (maximum 10/100 MBit can be used)

EXTENT OF SUPPLY

• The number of conversations the G7-WAN can handle • All Calls / Radio Conferences with 3.5 or 7 kHz

1 network card including: • Installation board GEA-WAN • 2 connection cables 0.5 m (for G7-GEV to G7-WAN or for multiple G7-WAN, G7-CNET-LAN, G7-CNET-E1 or G7-CNET-W) • Short reference • CD with software and manuals

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 1.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.

www.commend.com

P2|5


DATASHEET

G7-WAN

Planning Information REQUIRED BANDWIDTH The required Bandwidth (3.) is calculated by adding the connections (1.) and the data bandwidth (2.).

1. CONNECTIONS Required Bandwidth incl. protocol overhead, for upload/download each: Type of connection

Audio band width

Compression

Number of possible connections

Required bandwidth per connection

Conversation, All Call, Radio Conference, Music

7 kHz

Compressed

8

82 kBit/s

Conversation between 2 digital subscribers

3.5 kHz

Uncompressed (can not be compressed)

16

82 kBit/s

Radio Conference, Music

3.5 kHz

Uncompressed (can not be compressed)

16

82 kBit/s

All Call / Group Call

3.5 kHz

Uncompressed (can not be compressed)

15 (one channel occupied by gong)

82 kBit/s

2. DATA BANDWIDTH kBit/s 3000

2500

max.

2000

Signalling data depending on the network functions used (e.g. call transfers, etc.)

1500 Signalling data

min.

1000

500

10

20

30

40

50

60

70

Number of centrals in LAN/WAN

3. TOTAL BANDWIDTH kBit/s

reserved QoS bandwidth

1250

Signaling data Signaling data depending on the network functions used (e.g. call transfers, etc.)

1000

Signaling data after Traffic shaping

750

500 Up to 8 Audio-Connections (82 kBit/s each with constant bit rate)

250

t

REQUIREMENTS OF THE NETWORK YES

Dedicated Network

A dedicated network always consists of equipment of one type, e.g. only G7-WAN

YES

Non Dedicated Network with QoS (Quality of Service)

QoS controls the data stream in the network and ensures, that the speech packets are delivered within the demanded time

NO

Non Dedicated Network without QoS (Quality of Service)

99 % of all Corporate Networks, that are between 3 and 5 years old, are Non Dedicated Networks!

IP-Addresses and Ports: • Each G7-WAN must have a fixed IP-address • The communication to the central requires port 16384 (can be changed) QoS Requirements: • Maximum one-way-delay 100 ms • Delay-Jitter not above 50 ms • 0% packet loss for perfect audio quality Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 1.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.

www.commend.com

P3|5


DATASHEET

G7-WAN

Planning Information MAXIMUM EXPANSION • Up to 120 regions • Up to 14,280 networked Intercom Servers • Up to 30,000 subscribers are able to communicate with each other within the entire WAN network

1. CALCULATE THE NUMBER OF WAN-CLIENTS The following counts as a WAN-client: • Each intercom terminal, that initiates or receives conversations across a WAN-connection • Each input, that initiates a input message across a WAN-connection • Each output which is switched across a WAN-connection (via dialling or as attendant contact). Outputs which are switched via after dialling (e.g. door openers) do not count as WAN-client. • Include a reserve of clients for future expansions!

2. NUMBER OF VIRTUAL CENTRAL NUMBERS PER REGION • Virtual central numbers must be unique (only supra-regional, therefore multiple WAN-cards within a region central can share a virtual number). • Per 250 WAN-Clients one virtual central number is required. • The range for virtual central numbers is 136 to 255. Therefore a maximum of 120 virtual central numbers are available; each region requires a minimum of one virtual number so a maximum of 120 regions are possible.

3. MAXIMUM CENTRAL NUMBER 239 • Available central numbers: 1 to 119. Available virtual central numbers: 136 to 255.

4. NUMBER OF G7-WAN (MAXIMUM OF 4 PER CENTRAL) • Calculate the required amount of G7-WAN depending on the number of connections to the regions • A maximum of 64 connections per central(housing) is possible. If more connections are required a second GE 700 can be used, however this housing needs a separate virtual central number. • Therefore, if all centrals need to communicate with each other a maximum of 64 regions can be realised.

EXAMPLE FOR CENTRALS WITH 48 CLIENTS Each region can talk with all other regions (complete network): Centrals / Region:

120

5

60

10

40

15

30

20

24

26

20

31

17

36

15

41

13

46

12

52

10

62

9

67

8

78

7

88

6

104

5

119

140 120

Number of regions

Regions:

100 80 60 40 20 0 0

20

40

60

80

100

120

140

Centrals per region

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 1.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.

www.commend.com

P4|5


DATASHEET

G7-WAN

Installation INSTALLATION

PRECAUTIONS

• For connection of the G7-WAN the enclosed installation board GEA-WAN has to be used.

• ESD precautions must be observed.

• In a central GE 700 the card can be installed in the slots 8 to 12, A or B of the central, a maximum of 4 network cards (G7-WAN, G7-CNET-LAN, G7-CNET-W and G7-CNET-E1 all together) per housing.

• Mounting and installation of the centrals and of the equipment may be carried out by authorised service personnel only.

• In a central GE 200 the G7-WAN-8 card can be installed in the slots 9 or 10 of the central (interface housing GEI 200, a maximum of 2 cards). The G7-WAN-16 card is not supported in a GE 200.

CONNECTION GE 700 G7-WAN Slot 12

G7-WAN Slot 11

GEAC 700

GEA-WAN

GEA-WAN

OUT1 IN1 OUT2 IN2

UPLINK DOWNLINK

UPLINK DOWNLINK

OUT2 IN2

OUT2 IN2

SYSTEM CONFIGURATION • It is not possible, to define two parallel G7-WAN between two centrals. It is also not possible, to establish a second connection over other centrals (e.g. like a ring) – Except for redundancy. • Attention: If Ring 2 is used for connection of centrals GE 700 over G7-GEV, no G7-WAN can be used in this housing, because Ring 2 would have to be connected to the G7-WAN. Example:

GE 700 #1 G7-GEV Slot C

• Cards may be exchanged only with voltage switched off.

G7-WAN

IP

GE 700 No. 1

8/ 8/

OUT2 IN2

8/ 8/

G7-WAN

GE 700 No. 2

GE 700 #2 G7-GEV Slot C GEAC 700

OUT1 IN1 OUT2 IN2

OUT2 IN2

GE 700 #3 G7-WAN Slot 12

G7-GEV Slot C

GEA-WAN

GEAC 700

OUT1 IN1 OUT2 IN2

UPLINK CNET DOWNLINK

OUT2 IN2

G7-WAN Slot 12 GEA-WAN UPLINK CNET DOWNLINK

G7-WAN

GE 700 No. 3

OUT2 IN2

OUT2 IN2

Connection GEV-Ring: Connection G7-GEV with G7-WAN (and G7-CNET-E1, G7-CNET-W or G7-CNET-LAN) over “Ring 2“.

OUT2

G7-GEV OUT1 IN1 OUT2 IN2 G7-GEV OUT1 IN1 OUT2 IN2

no G7-WAN in this central!

GE 700 No. 5

OUT2 IN2

OUT1 IN1 OUT2 IN2

G7-GEV OUT1 IN1 OUT2 IN2

UPLINK

DOWNLINK

IN2

OUT1 IN1 OUT2 IN2

G7-GEV

GE 700 No. 4

G7-WAN

INSTALLATION BOARD GEA-WAN

G7-GEV

• The G7-WAN is connected to the network via the RJ 45 socket “UPLINK“. • Via the socket “DOWNLINK” five further LAN/WAN/IP cards can be connected in series (even across multiple housings).

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 1.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.

www.commend.com