Input/output cards GE 100/GE 200 I/O The input/output cards are part of the unique interface concept of the Intercom Servers GE 100 and GE 200. They enable various control and indication functions and thus upgrade the central units to universal control units for all kinds of activating and sensoring. The different designs of these cards allow flexible configuration, adapted to the customer‘s needs. The inputs read in
1.
G1-16A, G2-16A Plug-in card with 16 outputs (4 can be connected as normally open contacts, normally closed contacts or change over contacts, the other 12 as normally open contacts). The card is equipped with pluggable screw terminals.
2.
G1-16E, G2-16E Plug-in card with 16 inputs for floating (volt-free) contacts. The card is equipped with pluggable screw terminals.
up to 5 states of floating (volt-free) contacts. The outputs are floating (volt-free) relay contacts, designed as normally open, normally closed or change over. The different functions for the individual inputs and outputs can be defined in an easy and user-friendly way with the configuration tool for Windows® (supplied with the Intercom Servers).
3.
G1-8E8A, G2-8E8A Plug-in card with 8 inputs for floating (volt-free) contacts and 8 outputs (can be connected as normally open contact, normally closed contact or changeover). The card is equipped with pluggable screw terminals.
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 2.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.
www.commend.com
P1|3
DATASHEET
GE 100/GE200 I/O
Technical Data – Benefits TECHNICAL DATA
BENEFITS
Operating temperature range: Storage temperature range: Relative humidity: Plug: Power supply:
0°C to +50°C (32° F to 122° F) –30°C to +60°C (–22° F to 140° F) 20% to 80% 40-way socket
Emergency power consumption G1-16E, G2-16E: minimum: 10 mAh/h (idle), maximum: 70 mAh/h (all inputs active) Emergency power consumption G1-8E8A, G2-8E8A: minimum: 10 mAh/h (idle), maximum: 170 mAh/h (all relays and all inputs active)
Weight including package:
• Control of contacts (e.g. door opener relay, barrier control, etc.) • Each input can read in 5 different states: Idle mode, Active 1, Active 2, Short circuit, Line break
from central
Emergency power consumption G1- 16A, G2-16A: minimum: 10mAh/h (idle), maximum: 250mAh/h (all relays active)
Measurements:
• Monitoring of inputs (e.g. sensors, door status, barrier broken, etc.)
60 x 160 mm (2.36 x 6.30 inch) G1-16-A, G2-16A: 204 g (0.45 lbs) G1-16E, G2-16E: 146 g (0.32 lbs) G1-8E8A, G2-8E8A: 182 g (0.4 lbs)
SYSTEM REQUIREMENTS • For G1-16A and G1-16E central software min. Pro 04.1E is required, for programming the corresponding configuration tool (minimum TE 700 version 4.1B) is required. • In a GE 200 the G2-8E8A works only with firmware min. V02.2.
EXTENT OF SUPPLY 1 input/putput card including: • Short reference
OUTPUTS System: Maximum switching power:
Floating relay contacts 60 W / 125 VA
Maximum switching current:
2A
Maximum switching voltage:
60 VDC / 40 VAC
INPUTS System: Maximum line resistance:
for floating relay contacts 600 Ohm
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 2.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.
www.commend.com
P2|3
DATASHEET
GE 100/GE200 I/O
Installation PRECAUTIONS
MOUNTING INSTRUCTIONS
• ESD precautions must be observed.
• The cards can be installed in all slots of the GE 100/GE 200.
• Cards may be inserted and removed only with voltage switched off.
• A maximum of 2 input/output cards can be used in the GE 100/GE 200 plus 2 input/output cards in the expansion central GEZ 100/GEZ 200.
• Mounting and installation of the centrals and of the equipment may be carried out by authorised service personnel only. • No voltage may be connected to the inputs of the G1-8E8A/G2-8E8A and G1-16E/G2-16E. Only FLOATING CONTACTS like e.g. relay contacts, contactors, keys or switches may be connected.
CONNECTION G2-16A/G1-16A
Status LEDs for S1 to S8
S1W S1 S2W S2 S3W S3 S4W S4 S5W S5 S6W S6 S7W 7S S8W S8 S1 S2 S3 S4 S5 S6 S7 S8
1 2 3 4 5 6 7 8
Status indication 8E8A card IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8
S5W S5 S6W S6 S7W S7 S8W S8 S9W S9 S10W S10 S11W S11 S12W S12 S13W S13 S14W S14 S15W S15 S16W S16
S1W S1 S2W S2 S3W S3 S4W S4 S1 S2 S3 S4
CONNECTION G1-8E8A/G1-8E8A Status LEDs for S1 - S8
Status indication output card
Input 1-8
1 2 3 4 5 6 7 8
CONNECTION G1-16E/G2-16E Status LEDs for IN1-IN8 IN9 IN10 IN11 IN12 IN13 IN14 IN15 IN16
IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8
Status indication input card
1 2 3 4 5 6 7 8
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 2.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.