DATASHEET
GE 200
1
3
2
Compact System Intercom Server GE 200 Compact and suitable for networks, the GE 200 Intercom Server is ideal for Intercom systems where small, manageable units are combined to form a network. Each GE 200 acts as an Intercom Server that controls the different interfaces: interface cards for speech, control and indication functions and communication with other systems such as video systems, door and gate control, telephone systems, and more. The simple modular construction of the basic operating system
enables continuous upgrading for new applications and features. The latest SMD design results in the system being physically compact and conforming to the highest standards of electronic reliability. All kinds of Intercom stations, 2-wire, 4-wire as well as IP-stations, can be connected to the GE 200. Connection of the special GEI 200 interface housing also allows cards from the GE 700 to be used.
1. GE 200
2. GE 200 (bottom) with GEZ 200 (top)
Basic central including power supply, with five plug-in slots. Slots 1 to 4 for subscriber cards (for up to 16 subscribers) and/or interface cards. Slot A for interface cards only. One AF input (for music or alarm); two inputs for floating contacts; two relay outputs; interface for (remote) programming or maintenance.
Expansion central including power supply with 5 plug-in slots. Slot 5 to 8 for subscriber cards (up to 32 subscribers with basic housing) and/or interface cards, Slot B for interface cards only.
3. GEI 200 Interface housing with two slots for G7-interface cards.
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 3.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.
www.commend.com
P1|8
DATASHEET
GE 200
Technical Data - Benefits TECHNICAL DATA
BENEFITS
AC power supply:
24 V +/–5% / 40 VA / 16 subscribers
DC power supply:
24 – 35 V / 40 W / 16 subscribers
Emergency power consumption: 200 mAh/h (without cards) cards see corresponding data sheet Power consumption:
minimum (no conversation): 8 VA, maximum (All Call): 40 VA
Frequency range:
internal 300 – 16,000 Hz
Distortion:
less than 0.9%
Operating temperature range: 0° C to +50° C (32° F to 122° F)
• Compact plastic housing suitable for wall mounting • Easy installation and start-up • More than 150 standard features (a detailed list is available separately) • Latest Intercom technology: microprocessor-controlled, high density design, SMD production, object-orientated programming • For all kinds of Intercom stations (IP, 2-wire and 4-wire)
Storage temperature range: –30° C to +60° C (–22° F to 140° F)
• Digital networking over IP, 2-wire lines, E1 or ISDN
Relative humidity:
• Integrated functions for door/gate control, alarms, conferences and central control desks
20% to 80%
Measurements of the housing: Weight including package:
310 x 210 x 77.5 mm (12.21 x 8.27 x 3.05 inch) GE 200: 2210 g (4.87 lbs) GEZ 200: 2160 g (4.76 lbs) GEI 200: 1077 g (2.37 lbs)
Mounting: Relay outputs:
Wall mounting max. switching capacity: 60 W / 125 VA, max. switching current: 2A max. switching voltage: 60 VDC / 40 VAC
Music input: Inputs IN1, IN2:
• Plug&Play CCTV integration • Flexible expansion by means of different feature packages • Wide range of applications • User-friendly programming with PC software (included in extent of supply) • Remote programming via modem
max. 800 mV at 600 Ohm for floating contacts, max. line resistance: 1.5 kOhm
EXTENT OF SUPPLY • GE 200: Basic central including CD “Software and Manuals” and short reference
EXPANSION Subscribers:
Outputs:
0
2
Inputs: • GEZ 200: Expansion central including short reference
Basic expansion:
2 • GEI 200: Interface housing including short reference
Maximum expansion:
see “Plug-in Position of the Cards” The types of GE 200 and GEZ 200 differ in extent of supply: • GE 200, GEZ 200: including transformer 230 V Europe • GE 200AU, GEZ 200AU: incl. transformer 230 V Australia • GE 200U, GEZ 200U: including transformer 120 V USA • GE 200TE, GEZ 200TE: without transformer
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 3.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.
www.commend.com
P2|8
DATASHEET
GE 200
Installation PRECAUTIONS
PROGRAMMING CABLE
• With regard to the CE mark, the central is suitable for the following types of application: residential buildings, office and commercial premises, small businesses and industrial premises with public low-voltage mains supply.
For programming of the GE 200 a 9-way D-Submin connection cable is required (1:1, plug on central side, socket on PC side):
• Defective power cables of the transformer may not be repaired or changed. In case of defective power cables, the whole transformer must be changed. • Mounting and installation of the central GE 200 and of the equipment may be carried out by authorised service personnel only. • Cards may be inserted or removed only with voltage switched off. • Before exchanging of cards, ESD precautions must be observed. The “–“ terminal of the motherboard G2-GEM (see “Mounting, Cable Run” at page 8) is used as grounding point for Wrist Strap Grounding.
NC TXD RXD NC GND NC NC NC NC
1 2 3 4 5 6 7 8 9
GE 200 (9-way D-Submin plug)
1 2 3 4 5 6 7 8 9 (9-way D-submin jack) PC
NC = not connected This cable can be purchased at an electric outfitter or ordered with the type “X-KAB-CCT“.
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 3.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.
www.commend.com
P3|8
DATASHEET
GE 200
Installation LINK CARDS A link card is required for two reasons: 1. If a GE 200 (GEZ 200) contains analogue (4-wire) subscriber cards or an analogue telephone interface, a link card G2-GEK2-3 is required. 2. If features like “Reception of several music programs“, “Conference“ or “Radio conference“ are used (only in case of feed-in via analog subscriber cards), additional link cards G2-GEK2-3 are required (for music 4T1 no link card is required). Available per link card G2-GEK2-3 (a maximum of 3 G2-GEK2-3 in one GE 200 with GEZ 200): • 2 duplex controllers (only two duplex controllers can be used in the central, that means, from additional cards only the A/D converters can be used). • 3 A/D converters (a maximum of 9 A/D converters can be used) If only 2-wire subscribers are used, no link card is required. Available in the GE 200 (and GEZ 200) • 48 digital audio lines • 12 analogue audio lines The different types of conversation require a different number of audio lines, the free lines are allocated dynamically (see below).
REQUIRED LINES
Digital - Digital
A/D converter
Duplexcontrollers
Digital audio lines
Analogue audio lines
Simplex
-
-
1
-
16
Switched duplex
-
-
2
-
16
OpenDuplex
-
-
2
-
16
Simplex
1
-
1
1
9
®
Analogue - Digital
Analogue - Analogue
Switched duplex
1
1
2
4
2
Full Duplex
1
-
2
2
6
Simplex
-
-
-
1
12
Switched duplex
-
1
-
4
2
Full Duplex
-
-
-
2
6
1 per channel
-
1
1
9 channels
Digital, 7 kHz
-
-
1
-
32 channels 2
Digital, 3,5 kHz
-
-
1/2
-
32 channels 2
Analogue Feed-in of audio signals 1
max. conversations (incl. GEZ)
1
Features like “feed in of music programs“, “conferences“ or “radio conferences“. For music 4T1 none of the mentioned lines are required (internal music bus). 2 – 32 channels if only digital subscribers are in the central – 32 channels if analogue and digital subscribers are in the central, but only digital subscribers are receivers – 9 channels when analogue and digital subscribers are receivers
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 3.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.
www.commend.com
P4|8
DATASHEET
GE 200
Installation PLUG-IN CARDS FOR GE 200 Subscriber cards: • G2-DSP-IP-8B, C, D, P: for eight IP-stations • G2-DSP-IP-4B, C, D, P: for four IP-stations • G7-DSP-TEL-4C, D: for four analogue telephones • G2-GET-4B, C, D: for four 4-wire Intercom stations • G2-GED-4B, C, D: for four 2-wire Intercom stations Link cards: • G2-GEK2-3: 2 duplex controllers and 3 AD/DA converters Input/output cards: • G2-8E8A: 8 inputs for floating (volt-free) contacts and 8 floating (volt-free) relay contacts • G2-16A: 16 outputs (floating (volt-free) relay contacts) • G2-16E: 16 inputs for floating (volt-free) contacts Interface cards: • G7-V24-PROIP: IP interface card with programmable protocol converter and additional RS232 (not programmable). The card works with separately available driver software only! Plug-in card in Euro card format, therefore an interface housing GEI 200 is required. • G7-V24-PRO: Programmable V24-card with two RS 232-interfaces, of which one can be configured as RS 422. Attention: The card works with separately available driver software only! Plug-in card in Euro card format, therefore an interface housing GEI 200 is required. • G2-V24: V24 interface card with two RS 232, of which one can be configured as RS 422 • G2-TEL: Analogue telephone interface • G7-TEL: Analogue telephone interface (plug-in card in Euro card format, therefore an interface housing GEI 200 is required - only one G2-TEL may be used in the GE 200/GEZ 200) • G7-SELCALL: Radio interface (plug-in card in Euro card format, therefore an interface housing GEI 200 is required. Both slots of the GEI 200 are occupied by the G7-SELCALL and the enclosed G7-V24-PRO!) • G7-DSP-AUD4B, C, D: Digital Audio-Recording-Card with four audio channels (IN/OUT) and four relay contacts. Plug-in card in Euro card format, therefore an interface housing GEI 200 is required. Connection cards: • G2-CNET-LAN: IP network card for connection of up to 100 Intercom Servers (GE 200, GE 700, GE 700-2) via Ethernet (corresponding to IP protocol). Attention: It is not possible to operate additional network cards besides the G2-CNET-LAN! • G7-CNET-LAN: IP network card for connection of up to 100 Intercom Servers (GE 200, GE 700, GE 700-2) via Ethernet (corresponding to IP protocol). Plug-in card in Euro card format, therefore an interface housing GEI 200 is required. • G7-WAN-8: IP-Network card for WAN networking over IP of up to 120 regions. Allows security and communication networks with up to 14,280 networked Intercom Servers (up to 30,000 subscribers). Up to 8 Intercom Servers can be addressed directly. Plug-in card in Euro card format, therefore an interface housing GEI 200 is required. • G7-CNET-E1: E1 network card for connection of up to 100 Intercom Servers GE 200/GE 700 over multiplexer con-nections or media converters, like e.g. fibre optic (plug-in card in Euro card format, therefore an interface housing GEI 200 is required) • G7-CNET-W: network card for connection of up to 100 Intercom Servers GE 200/GE 700 over 2 wires up to 4 km (2.48 miles) (plug-in card in Euro card format, therefore an interface housing GEI 200 is required) • G2-S0-I: network card for connection of up to 16 Intercom Servers GE 200/GE 700 over ISDN dial up connections (one ISDN-basic rate interface, plug-in card in Euro card format, interface housing GEI 200 is required) • G2-GEL: tieline card for one leased line connection to another Intercom Server, optional 2-wire or 4-wire
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 3.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.
www.commend.com
P5|8
DATASHEET
GE 200
Installation PLUG-IN POSITION OF THE CARDS The plug-in cards can be inserted in the following slots: GE 200 1
2
GEZ 200
Card type
A
3
4
B
G2-GET-4B, C, D
-
G2-GED-4B, C, D
-
G2-DSP-IP-4B, C, D, P
-
-
G2-DSP-IP-8B, C, D, P
-
-
5
max. per GEZ 200
max. per GEI 200
-
-
-
4
4
-
-
-
-
4
4
-
-
-
4
4
-
-
-
4
-
-
G2-GEK2-3
-
-
G2-8E8A
-
-
G2-16A
-
-
G2-16E
-
-
-
-
-
8
max. per GE 200
10
-
7
Maximum number of cards
9
-
6
GEI 200
-
G2-TEL 1
G7-TEL
G2-V24
-
2
G7-V24-PRO
2
G7-V24-PROIP
2
G7-SELCALL 3 G2-CNET-LAN
4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
together 2
-
together 2
-
1
1
-
-
-
11
2
2
1
1
-
-
-
-
22
-
-
-
-
22
-
-
-
-
13
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
together 3
-
-
-
-
4
-
together 1
-
G7-CNET-LAN
-
-
-
-
-
-
-
-
-
-
-
-
2
G7-WAN-8
-
-
-
-
-
-
-
-
-
-
-
-
2
G7-CNET-E1
-
-
-
-
-
-
-
-
-
-
-
-
2
G7-CNET-W
-
-
-
-
-
-
-
-
-
-
-
-
2
G7-DSP-AUD4B, C, D
-
-
-
-
-
-
-
-
-
-
G7-DSP-TEL4C, D 5
-
-
-
-
-
-
-
-
-
-
G2-FAN-I
-
-
-
-
-
-
-
-
-
-
G2-S0-I 6
-
-
-
-
-
-
-
-
-
-
G2-GEL
-
-
-
-
-
2
-
-
15
-
-
1
-
-
26
2
2
-
1
If a G7-TEL is used only one G2-TEL may be used in the GE 200 or GEZ 200 2 All together a maximum of two G2-V24, G7-V24-PRO and G7-V24-PROIP can be used (e.g. one G2-V24 and one G7-V24-PRO) 3 The second slot of the GEI 200 is occupied by the G7-V24-PRO delivered with the G7-SELCALL 4 It is not possible to operate additional network cards besides the G2-CNET-LAN! 5 When a G7-DSP-TEL4 is used the card G2-FAN-I must be inserted in slot 10 6 Two G2-S0-I can be used only in a special system configuration, see manual “G7-S0, G2-S0-I“
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 3.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.
www.commend.com
P6|8
DATASHEET
GE 200
Installation MOUNTING, CABLE RUN 306 mm (12.1 inch) 290 mm (11.4 inch)
GEI 200
GEZ 200 Expansion Central
206 mm (8.1 inch)
180 mm (7.1 inch)
max. 120 mm (4.7 inch)
max. 120 mm (4.7 inch)
110 cm (4.3 inch) Grounding point for wrist strap grounding
GE 200
+30V
A B C D
Cable bearer
4 / 4 /
110 cm (4.3 inch)
/2
RJ11-Socket 24VAC supply
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 3.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.
www.commend.com
P7|8
DATASHEET
GE 200
Installation CONNECTION DIAGRAM
GEI 200 Slot 9
Slot 10
GEI 200
!
No subscriber cards in the interface slots (A,B)
8
e.g. G2-GET-4
Expansion plug
7
e.g. G2-GET-4
Interface slot (e.g. G2-GEK2-3)
GEI 200
e.g. G2-GET-4
Slot number B 5 6
e.g. G2-GET-4
GEZ 200
50
60
70
80
51
61
71
81
52
62
72
82
53
63
73
83
+ -
30VDC output max. 100mA
+30V 24 VAC 24 VAC
+
30VDC supply
Subscriber numbers with standard program
GEZ 200 (or GEI 200)
IN2 S1 S2
10 11 12 13
e.g. G2-GET-4
MUSIC IN1
Power ON OFF
4
e.g. G2-GET-4
Programming plug
3
e.g. G2-GET-4
Floating contacts
Expansion plug
e.g. G2-GED-4
Music / Alarm input
Slot number A 1 2
Interface slot (e.g. G2-GEK2-3)
GE 200
20
30
40
21
31
41
22
32
42
23
33
43
StatusLED + +30V 24 VAC 24 VAC
+
30VDC output max. 100mA 30VDC supply
12 34
Subscriber numbers with standard program
DIP switches e.g.: Door opener Power supply
A B A B
A B C D
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · office@commendusa.com · www.commendusa.com Datasheet Version 3.0/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice.
www.commend.com
P8|8