Sonora Solar Engineering / Services Portfolio / 2021

Page 1



About Us Sonora Solar Engineering is a company based in Tempe, AZ. We offer a wide range of services to support every stage of your solar business. From the conceptual design and site plan layouts through the building permitting and utility interconnection processes, and to the post-construction documentation.

Summary On the following pages you will find a summary of our services. - Sales material - Building plans - Miscellaneous Plans - Post Construction Material


Sales


Sales Material

Our team will help you develop sales material such as site plan layouts and 3D renderings showing proposed solar system on roofs or structures. We offer future Solar Structure year-round shade analysis that provides a comprehensive look at the shade provided by their new structure. Our engineering team will help you size your solar project based on Consumption analysis from bills. Sonora solar Engineering provides a full site audit investigation. Including photos, measurements, existing electrical gear audit, drone based photography and video, drone based site mapping, local AHJ and Utility requirements, and existing building planset analysis.

Bill Usage Analysis

Bill Usage Analysis Project Name: Acc #: Meter #: Location: Proposed Offset: Sun Hours: No. 1 2 3 4 5 6 7 8 9 10 11 12

Bill Date Jan-20 Feb-20 Mar-20 Apr-20 May-20 Jun-20 Jul-20 Aug-20 Sep-20 Oct-20 Nov-19 Dec-19

Total Usage (kWh) System Size (kW) Total System Size w/Offset (kW)

Project Name: Acc #: Meter #: Location: Proposed Offset: Sun Hours:

Delanco, NJ 95% MAIN METER Energy Usage (kWh) 24070.00 19489.00 17065.00 16368.00 13447.00 18468.00 23632.00 22553.00 21095.00 16365.00 15112.00 20080.00 227744.00 182.20 173.09

Demand (kW) 50.00 47.30 54.10 38.00 38.80 53.60 54.50 58.00 53.40 44.80 45.10 55.70 593.30

No. 1 2 3 4 5 6 7 8 9 10 11 12

Bill Date Jan-20 Feb-20 Mar-20 Apr-20 May-20 Jun-20 Jul-20 Aug-20 Sep-20 Oct-19 Nov-19 Dec-19

Total Usage (kWh) System Size (kW) Total System Size w/Offset (kW)

Delanco, NJ 95% Energy Usage (kWh)

Demand (kW)

12320.00 10640.00 8960.00 7400.00 5840.00 10400.00 23040.00 6320.00 11520.00 8240.00 9520.00 12400.00

49.60 47.20 33.60 76.00 85.60 70.40 56.00 73.60 44.00 48.80

126600.00 101.28 96.22



GIANT FITNESS GYM

262 PV modules of 370W for 96.94 kW.

901

464

total P V modules approx.

total PV modules approx.

204.16 kW

310 kW*

*

of power produced approx.

of power produced approx.

Plan View Plan view

Plan view * Using a 370 and 345 kW PV module

* Using a 440 kW PV module

NT FITNESS 262 PV modules of 370W for 96.94 kW.

Perspective view.

Perspective view.

Exterior View / Carport #1


Solar Projects


Photovoltaic Design PHOTOVOLTAIC SYSTEM ELECTRICAL INFORMATION 99,990 WATT DC PHOTOVOLTAIC SYSTEM (303 MODULES OF 330W EACH)

EX. BUILDING "E"

EX. BUILDING "D"

PROJECT DATA PROJECT DESCRIPTION:

EX. BUILDING "G"

EX. BUILDING "B"

EX. BUILDING "A"

EX. PARKING LOT

EX. PARKING LOT

1224'

EXISTING ZONING: R1-35

Maximum System Voltage = 1500V

SQ.FT SQ.FT. SQ.FT. SQ.FT. SQ.FT SQ.FT. SQ.FT. SQ.FT.

MALE PIN (-) CONNECTION

NORTH

%1.14 0#674#. 4756 2#6+0# *'+)6* Ä *+)*

MAX. MAX. MAX. MAX. MAX. MAX. MAX. MAX.

5ECNG Ä

3P-80A AC/DC DISC.

3P-60A

13 5

7

75.25 (NEC) AMPS @ 480V 3-# 2 AWG CU THWN-2 1-# 8 AWG CU THWN-2 NTL 1-# 8 AWG CU THWN-2 GND 1 1/4" EMT CONDUIT 10 FT MAX., VDR0P 0.05%

13

NEW. SWITCHGEAR JMT ELECTRICAL 800A 208Y/120V 60HZ. 3 PH, 4 WIRE, NEMA 3R, RATED 100 KAIC, WALL MOUNTED. SRP Meter 2

129.62 (NEC) AMPS @ 480V 3-# 250 KCMIL AWG AL THWN-2 1-# 04 AWG AL THWN-2 NTL 1-# 04 AWG AL THWN-2 GND 2 1/2" EMT CONDUIT 210 FT MAX., VDR0P 0.71%

M

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

ARRAY INFORMATION: Vmin = 33.20V x 17 = 564.40V ຎ Vmax = 50.32V x 17 = 855.44V Isc = 37.32A

285 FT MAXIMUM 1.5% VDROP.

PV SOURCE CIRCUITS TO 1000 VDC DISCONNECT SWITCH (INTEGRAL TO INVERTER) SEE SHEET E-2.2, E-2.3

4 LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH". SWITCH COVER TO BE LOCKED AT ALL TIMES. SWITCH TO BE VISUAL OPEN AND ACCESSIBLE PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22, AND IS RATED FOR THE AVAILABLE FAULT CURRENT

8

NOT USED.

9

NOT USED.

NOT USED.

12

NOT USED.

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

ARRAY INFORMATION: Vmin = 33.20V x 17 = 564.40V ຎ Vmax = 50.32V x 17 = 855.44V Isc = 27.99A

285 FT MAXIMUM 1.5% VDROP.

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

ARRAY INFORMATION: Vmin = 33.20V x 16 = 531.20V ຎ Vmax = 50.32V x 16 = 805.12V ຎ Isc = 27.99A

285 FT MAXIMUM 1.5% VDROP.

7

3P-80A

G

GFCI

5

A B C NG

10 17

13

NEW 400AF

15 16 18

6

PER SRP AFC = X 37,979 AMP

4

7

PHOTOVOLTAIC SYSTEM KWH METER 400A CT BASED METERING COMPARTMENT METER SOCKET 120/208V, NEMA3, 42 KAIC, ELECTRICAL MFG LLC JMT-403-0H-208 PV METER PROVIDED BY UTILITY

16 17

PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH 600VAC, 3-POLE, 200KA MAX. NON FUSED NEMA 3R, 400AMP SQD HU365R AFC = 19,604 AMP

SYSTEM #1 ELECTRICAL ONE-LINE DIAGRAM

f = (13857x 208 x 1.732 x 0.05) / (1000 x 112KVA) = 2.22 M = 1 / (1 + 2.22) = 0.30 Isc - (208x 0.30x 13857) / 480 = 1861.32 Amps

PHOTOVOLTAIC SYSTEM TRANSFORMER 3PH 112KVA 2.68KA/6.184 KA* 480Y/277V WYE -208V DELTA AFC = AFC = 1,861 AMP 13,857 AMP

M AFC = 16,237 AMP

X

299.03 AMPS (NEC) @ 208V 2 SETS OF: 3-# 3/0 AWG CU THWN-2 1-# 03 AWG CU THWN-2 NTL 1-# 03 AWG CU THWN-2 GND 2" EMT CONDUIT 35 FT MAX., VDR0P 0.27%

17

G

7

3-# 250 KCMIL AWG AL THWN-2 1-# 04 AWG AL THWN-2 NTL 1-# 04 AWG AL THWN-2 GND 2 1/2" EMT CONDUIT

AC/DC DISC.

13

X

299.03 AMPS (NEC) @ 208V 2 SETS OF: 3-# 3/0 AWG CU THWN-2 1-# 03 AWG CU THWN-2 NTL 1-# 03 AWG CU THWN-2 GND 2" EMT CONDUIT 15 FT MAX., VDR0P 0.09%

X

299.03 AMPS (NEC) @ 208V 2 SETS OF: 3-# 3/0 AWG CU THWN-2 1-# 03 AWG CU THWN-2 GND 2" EMT CONDUIT 15 FT MAX., VDR0P 0.09%

NOT USED.

20

NOT USED.

2 BI-DIRECTIONAL UTILITY METER INSTALLED BY UTILITY COMPANY (AS REQUIRED). NOT USED.

5 LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT DEVICE #" PER NEC 690.14(C)(2). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE, MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC 690.53. SWITCH TO BE LOCKED PER NEC 690.7(D).

NOT USED.

9

NOT USED.

2 SETS OF: 3-# 3/0 AWG CU THWN-2 1-# 03 AWG CU THWN-2 NTL 1-# 03 AWG CU THWN-2 GND 2" EMT CONDUIT

2

4

7

16 17

PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH 600VAC, 3-POLE, 200KA MAX. NON FUSED NEMA 3R, 400AMP SQD HU365R EX. 400AF

EX. 400AF

NEW 400A 3P PULLOUT PV SERVICE SWITCH W/ (3) 400 A RK1 FUSES 15 16 18

DESIGNED BY: REVIEWED BY: DATE: REV

BY

DATE

COMMENTS/CHANGES

11 GEC TO BE INSTALLED AS REQUIRED BY MANUFACTURER INSTRUCTIONS AND NEC 690.47. IRREVERSIBLE CONNECTION PER NEC 250.64(C)(1). NOT USED.

NOT USED.

15 A PLACARD OR DIRECTORY IS INSTALLED AT THE SERVICE ENTRANCE WITH EXPLICIT DIRECTIONS TO THE LOCATION OF THE PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH AS REQUIRED BY THE UTILITY.

6

17

PHOTOVOLTAIC SYSTEM KWH METER 400A CT BASED METERING COMPARTMENT METER SOCKET 120/208V, NEMA3, 42 KAIC, ELECTRICAL MFG LLC JMT-403-0H-208 PV METER PROVIDED BY UTILITY

M

2 SETS OF: 3-# 3/0 AWG CU THWN-2 1-# 03 AWG CU THWN-2 GND 2" EMT CONDUIT PHOTOVOLTAIC SYSTEM TRANSFORMER 3PH 112 KVA 2.68KA/6.184 KA 480Y/277V WYE -208V DELTA

A B C N

N

G

G

16 A PERMANENT PLACARD OR DIRECTORY IS INSTALLED PER NEC 705.10. THE MARKING SHALL COMPLY WITH NEC 110.21(B)

To see our full files and videos click here or scan our QR code.

17 EQUIPMENT SHALL BE TESTED, LISTED AND MARKED TO WITHSTAND THE AVAILABLE SHORT CIRCUIT CURRENT. 18 APPLY LABEL AT SERVICE PANEL/DISCONNECT "INTERACTIVE SYSTEM POINT OF INTERCONNECTION - PHOTOVOLTAIC POWER SOURCE "WITH MAXIMUM OPERATING CURRENT AND OPERATING AC VOLTAGE PER NEC 690.54. 19

NOT USED.

20

NOT USED.

EXISTING LOADS

2 SETS OF: 3-# 3/0 AWG CU THWN-2 1-# 03 AWG CU THWN-2 NTL 1-# 03 AWG CU THWN-2 GND 2" EMT CONDUIT

N G

X

11 1-#1/0 AWG SOL CU GND (G.E.C.)

PV SYSTEM ONE LINE DIAGRAM

E-2.2

TO UTILITY

We provide post-construction documentation for every project. We offer post-production construction documentation including as-built drawings, drone aerial video, and photos for future marketing purposes.

10 LABEL "DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL" AND "DO NOT ADD LOADS TO THIS PANEL"

14

M

*THE ISOLATION TRANSFORMER WILL LIMIT CURRENT THROUGH ITS IMPEDANCE.

E-2.1

1865 E 3RD ST. TEMPE, AZ 85281 (602) 288-6732 (OFFICE) WWW.SCOUTSOLAR.COM

KEY NOTES:

8

We provide everything you need to quickly receive your building permits and utility approvals. We offer management for the utility interconnection process and the permitting process of the authority having jurisdiction. We have worked with several AHJs and utilities around the country.

13 DC COMBINER BOX, LABEL "WARNING, DO NOT OPEN FUSES UNDER LOAD."

18 APPLY LABEL AT SERVICE PANEL/DISCONNECT "INTERACTIVE SYSTEM POINT OF INTERCONNECTION - PHOTOVOLTAIC POWER SOURCE "WITH MAXIMUM OPERATING CURRENT AND OPERATING AC VOLTAGE PER NEC 690.54. 19

1. ALL EQUIPMENT SHALL BE INSTALLED AND LABELED IN ACCORDANCE WITH THE NEC AND ALL APPLICABLE REQUIREMENTS OF THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION.

7 PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING-ELECTRIC SHOCK HAZARD-DO NOT TOUCH TERMINALS-TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION".

17 EQUIPMENT SHALL BE TESTED, LISTED AND MARKED TO WITHSTAND THE AVAILABLE SHORT CIRCUIT CURRENT.

EXISTING LOADS

ELECTRICAL STRING DETAILS

12

16 A PERMANENT PLACARD OR DIRECTORY IS INSTALLED PER NEC 705.10. THE MARKING SHALL COMPLY WITH NEC 110.21(B)

NEW 400A 3P PULLOUT PV SERVICE SWITCH W/ (3) 400 A RK1 FUSES

TEMPERATURE CORRECTED Vmax = 50.32 V Vmax = Voc ( 1+( [Tmin - Tstc] x [Temp Coefficient] ) )

6 LABEL "PHOTOVOLTAIC SYSTEM METER". METER ENCLOSURE AND SOCKET PROVIDED AND INSTALLED BY CUSTOMER. METER, CTs AND TEST SWITCHES PROVIDED BY UTILITY COMPANY WHEN REQUIRED.

3-# 4 AWG CU THWN-2 1-# 10 AWG CU THWN-2 NTL 1-# 10 AWG CU THWN-2 GND 1" EMT CONDUIT

NEW. SWITCHGEAR JMT ELECTRICAL 800A 208Y/120V 60HZ. 3 PH, 4 WIRE, NEMA 3R, RATED 100 KAIC, WALL MOUNTED.

NOT USED.

15 A PLACARD OR DIRECTORY IS INSTALLED AT THE SERVICE ENTRANCE WITH EXPLICIT DIRECTIONS TO THE LOCATION OF THE PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH AS REQUIRED BY THE UTILITY. NEW 400AF

TEMPERATURE CORRECTED Vmin = 33.20 V Vmin = Vmp ( 1+( [Tadd + Tmax - Tstc] x [Temp Coefficient] ) )

4 LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH". SWITCH COVER TO BE LOCKED AT ALL TIMES. SWITCH TO BE VISUAL OPEN AND ACCESSIBLE PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22, AND IS RATED FOR THE AVAILABLE FAULT CURRENT

MCB 3P-150A

3-# 2 AWG CU THWN-2 1-# 8 AWG CU THWN-2 NTL 1-# 8 AWG CU THWN-2 GND 1 1/4" EMT CONDUIT

AC/DC DISC.

15.84kW 3 SOURCE CIRCUITS SEE SHEET E-2.1 ARRAY 3

WALL MOUNTED INVERTER 36.0 kW INVERTER WITH INTEGRAL AFCP SOLECTRIA SOLAR PVI-36TL 36.0-3 480 240-1000 VDC TO 277/480 VAC, 43.5A OUTPUT, 3 , 4W, 60Hz 1000 VDC MAX INPUT VOLTAGE LISTED TO UL 1741 SA

STRING (16 MODULES) INFORMATION: Vmp = 604.8V Imp = 8.73A Voc = 739.2V Isc = 9.33A

PV SOURCE CIRCUITS TO 1000 VDC DISCONNECT SWITCH (INTEGRAL TO INVERTER) SEE SHEET E-2.4, E-2.5

PV done right.

We support installers until procurement of their Green Tags. We do RFI support during construction and minor design changes. Special P.E. field inspections are available. We coordinate with installers and engineers.

ARRAY 3 INFORMATION

13 DC COMBINER BOX, LABEL "WARNING, DO NOT OPEN FUSES UNDER LOAD." 14

STRING (17 MODULES) INFORMATION: Vmp = 642.6V Imp = 8.73A Voc = 785.4V Isc = 9.33A

15,840 WATT PHOTOVOLTAIC SYSTEM (48 MODULES)

ROOF MOUNTED ARRAYS

COMMENTS/CHANGES

COMMENTS/CHANGES

PV SOURCE CIRCUITS TO 1000 VDC DISCONNECT SWITCH (INTEGRAL TO INVERTER) SEE SHEET E-2.4, E-2.5

POLE MOUNTED PHOTOVOLTAIC SYSTEM (LOAD CENTER ) 250A, 480V, 3-PHASE, 4-WIRE, NEMA 3R. 65 KAIC SQD #NF430L2 W/MH38WP

16.83kW 3 SOURCE CIRCUITS SEE SHEET E-2.1 ARRAY 2

DATE:

DATE

GENERAL NOTES:

GFCI

5

DATE

BY

TEMPERATURE CORRECTED Vmax = 50.32 V Vmax = Voc ( 1+( [Tmin - Tstc] x [Temp Coefficient] ) )

3

DESIGNED BY:

BY

REV

16,830 WATT PHOTOVOLTAIC SYSTEM (51 MODULES)

3P-60A

REVIEWED BY:

REV

DATE:

ARRAY 2 INFORMATION

(3) PV OUTPUT CIRCUITS (6) #12 AWG PV WIRE (1) #10 SOLID BARE CU GND

22.44kW 4 SOURCE CIRCUITS SEE SHEET E-2.1 ARRAY 1

WALL MOUNTED INVERTER 50.0 kW INVERTER WITH INTEGRAL AFCP SOLECTRIA SOLAR PVI-50TL 50.0-3 480 200-950VDC TO 277/480 VAC, 60.2A OUTPUT, 3 , 4W, 60Hz 1000 VDC MAX INPUT VOLTAGE LISTED TO UL 1741 SA

10 LABEL "DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL" AND "DO NOT ADD LOADS TO THIS PANEL" 11

REVIEWED BY:

22.44kW 4 SOURCE CIRCUITS SEE SHEET E-2.1 ARRAY 1

NOT USED.

1865 E 3RD ST. TEMPE, AZ 85281 (602) 288-6732 (OFFICE) WWW.SCOUTSOLAR.COM

STRING (17 MODULES) INFORMATION: Vmp = 642.6V Imp = 8.73A Voc = 785.4V Isc = 9.33A

TEMPERATURE CORRECTED Vmax = 50.32 V Vmax = Voc ( 1+( [Tmin - Tstc] x [Temp Coefficient] ) )

(3) PV OUTPUT CIRCUITS (6) #12 AWG PV WIRE (1) #10 SOLID BARE CU GND

-

NEC 2014 & 2017 690.12 RAPID SHUTDOWN COMPLIANT.

1865 E 3RD ST. TEMPE, AZ 85281 (602) 288-6732 (OFFICE) WWW.SCOUTSOLAR.COM

7 PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING-ELECTRIC SHOCK HAZARD-DO NOT TOUCH TERMINALS-TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION".

54.37 (NEC) AMPS @ 480V 3-# 4 AWG CU THWN-2 1-# 10 AWG CU THWN-2 NTL 1-# 10 AWG CU THWN-2 GND 1" EMT CONDUIT 15 FT MAX., VDR0P 0.06%

+

ROOF MOUNTED ARRAYS

6 LABEL "PHOTOVOLTAIC SYSTEM METER". METER ENCLOSURE AND SOCKET PROVIDED AND INSTALLED BY CUSTOMER. METER, CTs AND TEST SWITCHES PROVIDED BY UTILITY COMPANY WHEN REQUIRED.

10 17

-

22.44kW 4 SOURCE CIRCUITS SEE SHEET E-2.1 ARRAY 1

5 LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT DEVICE #" PER NEC 690.14(C)(2). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE, MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC 690.53. SWITCH TO BE LOCKED PER NEC 690.7(D).

MCB 3P-150A

+

1

-

-

3

-

+

+

TIGO TS4-S JUNCTION BOX. TYP.

1.) LOCATE PRE-DRILLED HOLE IN SOLAR PANEL 2.) USE AN ABRASIVE MATERIAL TO REMOVE ANY CLEAR COAT OR ANODIZING FROM THE CONTACT SURFACE 3.) APPLY PENETROX (OXIDE INHIBITOR) IN THE AREA WHERE THE CONNECTOR WILL BE INSTALLED 4.) USE BOLT AND EXTERNAL TOOTH (STAR) LOCK WASHER TO MOUNT THE GROUND LUG TO SOLAR PANEL FRAME. 5.) LAY WIRE IN CONNECTOR AND TIGHTEN SET SCREW TO 35-IN-LB

(4)15A

+

A-1.0

10-32 STAINLESS STEEL HEX NUT

INSTALLATION INSTRUCTIONS

+ + + + +

-

(4)15A FUSE

(4)15A FUSE

+

GENERAL SITE PLAN

2 BI-DIRECTIONAL UTILITY METER INSTALLED BY UTILITY COMPANY (AS REQUIRED). 3

-

1

7

-

+++++ - - - - -

+

2

5

AC/DC DISC.

+

+++++ - - - - -

POLE MOUNTED PHOTOVOLTAIC SYSTEM (LOAD CENTER ) 250A, 480V, 3-PHASE, 4-WIRE, NEMA 3R. 65 KAIC SQD #NF430L2 W/MH38WP

-

3

-

-

+++++ - - - - -

#10 S.S. EXTERNAL TOOTH LOCK WASHER

KEY NOTES:

H

+

+

WALL MOUNTED INVERTER #2 50.0 kW INVERTER WITH INTEGRAL AFCP SOLECTRIA SOLAR PVI-50TL 50.0-3 480 200-950VDC TO 277/480 VAC, 60.2A OUTPUT, 3ɐ, 4W, 60Hz 1000 VDC MAX INPUT VOLTAGE LISTED TO UL 1741 SA

(4)15A FUSE

-

H

+

+++++ - - - - -

(3)15A FUSE

+++++ - - - - -

(3)15A FUSE

WALL MOUNTED INVERTER #1 36.0 kW INVERTER WITH INTEGRAL AFCP SOLECTRIA SOLAR PVI-36TL 36.0-3 480 240-1000 VDC TO 277/480 VAC, 43.5A OUTPUT, 3ɐ, 4W, 60Hz 1000 VDC MAX INPUT VOLTAGE LISTED TO UL 1741 SA

TINNED COPPER LAY-IN LUG 10-32 X .50 S.S. SLOTTED/HEX COMBINATION HEAD BOLT

(4)15A

22.44kW 4 SOURCE CIRCUITS SEE SHEET E-2.1 ARRAY 1 16.83kW 3 SOURCE CIRCUITS SEE SHEET E-2.1 ARRAY 2

15.84kW 3 SOURCE CIRCUITS SEE SHEET E-2.1 ARRAY 3

+

ARRAY WITH (3) PARALLEL STRINGS OF (16) GCL-P6/72 330 WATT SOLAR MODULES IN SERIES. FOR A TOTAL OF (48) SOLAR MODULES.

(4)15A

22.44kW 4 SOURCE CIRCUITS SEE SHEET E-2.1 ARRAY 1

-

MODULE GROUNDING DETAIL SCALE: N.T.S.

1. ALL EQUIPMENT SHALL BE INSTALLED AND LABELED IN ACCORDANCE WITH THE NEC AND ALL APPLICABLE REQUIREMENTS OF THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION.

22.44kW 4 SOURCE CIRCUITS SEE SHEET E-2.1 ARRAY 1

+

ARRAY 3 15,840 WATT PHOTOVOLTAIC ARRAY (3) STRINGS IN PARALLEL: (16) GCL-P6/72 330 WATT SOLAR MODULES IN SERIES.

GENERAL NOTES:

ROOF MOUNTED ARRAYS ROOF MOUNTED ARRAYS

-

NOTES:

+

5ECNG Ä

%10%'267#. 51.#4 5722146 5647%674' (4106 8+'9

+

1A

$

NEC 2014 & 2017 690.12 RAPID SHUTDOWN COMPLIANT.

+ + + +

%10%'267#. 51.#4 5722146 5647%674' 5'%6+10 8+'9

-

1. ALL MODULE INTERCONNECTIONS ARE #12 AWG PV WIRE SUNLIGHT RESISTANT MULTI CONTACT WIRE ASSEMBLY (TYPE IV). FIELD WIRING TO BE #12 AWG PV WIRE CU. 2. ALL MODULE GROUND INTERCONNECTIONS TO BE #10 AWG SOLID BARE COPPER UNLESS OTHERWISE NOTED 3. ALL MODULE GROUND CONNECTIONS SHALL USE STAINLESS STEEL HARDWARE WITH COPPER RATED LAY-IN-LUGS (ILSCO BGBL-4DBT OR BURNDY CL-50-1) 4. ALL MODULES CONNECT TO TIGO TS4-S JUNCTION BOX. MEETS NEC 690.12 RAPID SHUT DOWN REQUIREMENTS. LABEL "PHOTOVOLTAIC SYSTEM EQUIPED WITH RAPID SHUTDOWN AND PERMANENT PLAQUE OR DIRECTORY PER NEC 690.56(C).

99.99 kW DC / 86.0 KW AC PHOTOVOLTAIC SYSTEM

#

TIGO TS4-S JUNCTION BOX. TYP.

MULTI CONTACT TYPE IV MODULE CONNECTOR DETAIL

DEVELOPMENT AND USE OF THIS SITE WILL CONFORM WITH ALL APPLICABLE CODES AND ORDINANCES. THIS PROJECT IS LOCATED IN THE CITY OF PHOENIX WATER SERVICE AREA AND HAS BEEN DESIGNATED AS HAVING AN ASSURED WATER SUPPLY. ALL NEW OR RELOCATED UTILITIES WILL BE PLACED UNDERGROUND. ALL SIGNAGE REQUIRES SEPARATE APPROVALS AND PERMITS. ANY LIGHTING WILL BE PLACED SO AS TO DIRECT LIGHT AWAY FROM THE ADJACENT RESIDENTIAL DISTRICTS AND WILL NOT EXCEED ONE FOOT CANDLE AT THE PROPERTY LINE. NO NOISE, ODOR OR VIBRATION WILL BE EMITTED SO THAT IT EXCEEDS THE GENERAL LEVEL OF NOISE, ODOR OR VIBRATION EMITTED BY USES OUTSIDE OF THE SITE. OWNERS OF PROPERTY ADJACENT TO PUBLIC RIGHT-OF-WAY WILL HAVE THE RESPONSIBILITY FOR MAINTAINING ALL LANDSCAPING WITHIN THE RIGHTS-OF-WAY IN ACCORDANCE WITH APPROVED PLANS. AFTER FINAL APPROVAL THE PROJECT WILL BE INSPECTED FOR ZONING COMPLIANCE DURING CONSTRUCTION. ALL ROOFTOP EQUIPMENT AND SATELLITE DISHES SHALL BE SCREENED TO THE HEIGHT OF THE TALLEST EQUIPMENT. ALL SERVICE AREAS SHALL BE SCREENED TO CONCEAL TRASH CONTAINERS, LOADING DOCKS, TRANSFORMERS, BACKFLOW PREVENTERS AND OTHER MECHANICAL OR ELECTRICAL EQUIPMENT FROM EYE LEVEL ADJACENT TO ALL PUBLIC STREETS. ALL ON-SITE ACCESSIBLE SIDEWALKS SHALL BE A MINIMUM OF 3 FEET 0 INCHES WIDE AND HAVE A MAXIMUM SLOPE OF 1:20 WITH THE MAXIMUM CROSS SLOPE OF 1:50. ALL CURBS MUST PROVIDE ACCESSIBLE RAMPS PURSUANT TO THE AMERICANS WITH DISABILITIES ACT (ADA) STANDARDS. LANDSCAPE SHALL BE MAINTAINED BY A PERMANENT AND AUTOMATIC IRRIGATION SYSTEM TO MINIMIZE MAINTENANCE AND WATER CONSUMPTION.

/#6'4+#. 5647%674#. 56''.

-

+

TEMPERATURE CORRECTED Vmin = 33.20 V Vmin = Vmp ( 1+( [Tadd + Tmax - Tstc] x [Temp Coefficient] ) )

FEMALE SOCKET (+) CONNECTION

1. MODULE INTERCONNECTION CONNECTORS SHALL BE MARKED FOR POSITIVE AND NEGATIVE POLARITY PER NEC690.33 (A) 2. MODULE INTERCONNECTION CONNECTORS SHALL BE OF THE LOCKING OR LATCHING TYPE PER NEC 690.33 (C) 3. MODULES INTERCONNECTION CONNECTORS ARE EITHER CAPABLE OF INTERRUPTING THE CIRCUIT CURRENT WITHOUT DANGER TO THE OPERATOR, OR MARKED "DO NOT OPEN UNDER LOAD." PER NEC 690.33 (E)

MINOR COMMERCIAL SITE PLAN NOTES:

B

-

N

5ECNG Ä Ä

+

2

PROPOSED BUILDING/STRUCTURE HEIGHTS (STORIES/FEET): SOLAR SHADE STRUCTURE #1: ONE STORY/15'-0" MIN, 17'-0" SOLAR SHADE STRUCTURE #2: ONE STORY/15'-0" MIN, 17'-0" SOLAR SHADE STRUCTURE #3: ONE STORY/15'-0" MIN, 17'-0" SOLAR SHADE STRUCTURE #4: ONE STORY/15'-0" MIN, 17'-0" SOLAR SHADE STRUCTURE #5: ONE STORY/15'-0" MIN, 17'-0" SOLAR SHADE STRUCTURE #6: ONE STORY/15'-0" MIN, 17'-0" SOLAR SHADE STRUCTURE #7: ONE STORY/15'-0" MIN, 17'-0" SOLAR SHADE STRUCTURE #8: ONE STORY/15'-0" MIN, 17'-0"

*NOTE: SAME STRING DESIGN RULES AS TRADITIONAL MODULES

(3)15A

NORTH

Impedance Matching Function = No

(3)15A

#

5ECNG Ä Ä

Rapid Shutdown UL Certified = Yes

NEW TOTAL: 198,726.28 SQ.FT. (4.56 ACRES)

)'0'4#. 5+6' 2.#0

-

ARRAY WITH (3) PARALLEL STRINGS OF (17) GCL-P6/72 330 WATT SOLAR MODULES IN SERIES. FOR A TOTAL OF (51) SOLAR MODULES.

+

Minimum VMP = 16V OUTPUT Output Power Range = 0-475W Output Voltage Range = 0-VOC

+ + + +

PROPERTY LINE

(#%+.+6; 5+6' 2.#0

+

1A

NEW CARPORT STRUCTURE #3 & #6 (288) 390 WATT SOLAR MODULES ORIENTED DUE EAST/WEST AT A 5° ANGLE 15.0 FT MIN. CLEARANCE

603'

-

DESIGNED BY:

Maximum VOC @ STC = 75V

(3)15A

R=15'

+

ARRAY 2 16,830 WATT PHOTOVOLTAIC ARRAY (3) STRINGS IN PARALLEL: (17) GCL-P6/72 330 WATT SOLAR MODULES IN SERIES.

Max. Continuous Input Current (IMAX) = 12A COMMENTS/CHANGES

DATE

BY

+ + + + +

EX. PARKING LOT

REV

147,230 SQ.FT. 6,527.76 6,527.76 6,527.76 6,164.86 6,164.86 6,527.76 6,527.76 6,527.76

-

+

PROPERTY LINE

NEW ACCESSORY BUILDINGS: SOLAR CARPORT STRUCTURE #1: SOLAR CARPORT STRUCTURE #2: SOLAR CARPORT STRUCTURE #3: SOLAR CARPORT STRUCTURE #4: SOLAR CARPORT STRUCTURE #5: SOLAR CARPORT STRUCTURE #6: SOLAR CARPORT STRUCTURE #7: SOLAR CARPORT STRUCTURE #8: TOTAL: 51,496.28 SQ.FT

+

(4)15A

10,820 SQ.FT. 16,543 SQ.FT. 6,000 SQ.FT. 10,606 SQ.FT. 20,690 SQ.FT. 31,579 SQ.FT. 41,669 SQ.FT. 3,965 SQ.FT. 5,358 SQ.FT.

TOTAL EXISTING: NEW CARPORT STRUCTURE #7 & #8 (288) 390 WATT SOLAR MODULES ORIENTED DUE EAST/WEST AT A 5° ANGLE 15.0 FT MIN. CLEARANCE

Rated DC Input Power = 475W Max Input Voltage @ Lowest Temp = 90V

DESIGNED BY:

(4)15A

-

-

TIGO TS4-S SPECIFICATIONS:

+

B

2% WARM SEASON DESIGN DRY BULB TEMPERATURE (BY ASHRAE) = 43 DEG. C.

+ + + + +

-

CARPORT STRUCTURE

+

EXTREME ANNUAL MEAN MIN. DESIGN DRY BULB TEMP. (BY ASHRAE) = -2.86 DEG. C.

DATE:

"A": "B": "C-1": "C-2": "D": "E": "F": "G": "H":

-

MOUNTING TYPE: ROOF MOUNT (20 DEG. C TEMPERATURE ADDER)

(4)15A

A

BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING

+

SITE INFORMATION:

REVIEWED BY:

BUILDING SQUARE FOOTAGE: EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING

SHORT CIRCUIT CURRENT (Isc) = 9.33A TEMPERATURE COEFFICIENT (Voc) = -0.32 %/C

(3)15A

637'

N MILLER RD

NEW CARPORT STRUCTURE #1 & #2 (288) 390 WATT SOLAR MODULES ORIENTED DUE EAST/WEST AT A 5° ANGLE 15.0 FT MIN. CLEARANCE

-

INPUT

SITE ACREAGE: NET AREA = 803,553 SQ.FT. OR 18.44 ACRES

CARPORT STRUCTURE

+

OPEN CIRCUIT VOLTAGE (Voc) = 46.2V

-

CARPORT STRUCTURE

MAXIMUM POWER CURRENT (Imp) = 8.73A

+

EX. PARKING LOT

NEC 2014 & 2017 690.12 RAPID SHUTDOWN COMPLIANT.

-

EXISTING TREE TYP.

TIGO TS4-S JUNCTION BOX. TYP.

GCL-P6/72 330W SOLAR MODULE. SPECIFICATIONS @ STANDARD TEST CONDITIONS MAXIMUM POWER VOLTAGE (Vmp) = 37.8V

-

CARPORT STRUCTURE

LEGAL DESCRIPTION:

PROPERTY LINE

EX. BUILDING "A"

SOLAR MODULE SPECIFICATIONS:

- - - -

EX. BUILDING "D"

EX. BUILDING "G"

-

TEMPERATURE CORRECTED Vmin = 33.20 V Vmin = Vmp ( 1+( [Tadd + Tmax - Tstc] x [Temp Coefficient] ) )

- - - -

SCOTTSDALE BIBLE CHURCH

+

ONE WITH (3) PARALLEL STRINGS OF (16) GCL-P6/72 330 WATT SOLAR MODULES IN SERIES. GENERAL INFORMATION:

-

0' R=54

NEW CARPORT STRUCTURE #4 & #5 (272) 390 WATT SOLAR MODULES ORIENTED DUE EAST/WEST AT A 5° ANGLE 15.0 FT MIN. CLEARANCE

5ECNG 0 6 5

+

EX. BUILDING "B" EX. UTILITY TRANSFORMER

8+%+0+6; /#2

ONE WITH (3) PARALLEL STRINGS OF (17) GCL-P6/72 330 WATT SOLAR MODULES IN SERIES.

-

N

A

A-1.0

EX. BUILDING "F"

PHOTOVOLTAIC SYSTEM #1, 555.36 KW DC/ 396.00 KW AC PHOTOVOLTAIC SYSTEM #2, 330.72 KW DC/ 236.00 KW AC

EX. BUILDING "F"

EX. SES AND PV SYSTEM POINT OF INTERCONNECTION.

EX. BUILDING "C-1"

ARRAY 1 INFORMATION 22,440 WATT PHOTOVOLTAIC SYSTEM (68 MODULES) ARRAY WITH (4) PARALLEL STRINGS OF (17) GCL-P6/72 330 WATT SOLAR MODULES IN SERIES. FOR A TOTAL OF (68) SOLAR MODULES.

-

0' R=46

EX. BUILDING "E"

(4) PV OUTPUT CIRCUITS (8) #12 AWG PV WIRE (1) #10 SOLID BARE CU GND

FIVE ARRAYS: THREE ARRAYS WITH (4) PARALLEL STRINGS OF (17) GCL-P6/72 330 WATT SOLAR MODULES IN SERIES.

- - - - -

EX. BUILDING "C-2"

EX. BUILDING "H"

DEVELOPER:

-

EX. UTILITY TRANSFORMER

- - - - -

EX. PARKING LOT

1865 E 3rd St, Suite B Tempe, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

99.99 kW DC / 86.0 KW AC PHOTOVOLTAIC SYSTEM

EX. SES AND PV SYSTEM POINT OF INTERCONNECTION.

- - - - -

'

R=20

EX. PARKING LOT

ARRAY 1 22,440 WATT PHOTOVOLTAIC ARRAY (4) STRINGS IN PARALLEL: (17) GCL-P6/72 330 WATT SOLAR MODULES IN SERIES.

OWNER:

657'

99.99 kW DC / 86.0 KW AC PHOTOVOLTAIC SYSTEM

PROJECT TEAM PROPERTY LINE

EX. GROUNDING ELECTRODE SYSTEM

PV SYSTEM THREE LINE DIAGRAM

E-2.3


Electric Design 5

1 M

M

M

5

5 EX. 100AF

M

5 EX. 100AF

M 5

5

M

5

5

EX. 200AF

M

EX. 100AF

EX. 200AF

M 5

5

7

EX. 100AF

EX. 200AF

M

EX. 200AF

TYP.

2.

M

3.

5 EX. 100AF

4. 5.

EX. 40AF

6. 7.

EXISTING LOAD

#

EXISTING LOAD

PER SRP X AFC = 4 61,498 AMP

PER SRP 2 AFC = X 61,498 AMP 4

2

EXISTING LOAD

EXISTING EX. PNL "A" LOAD 200A, 208V, 3-PHASE, 4-WIRE, ': & '.'%64+%#. 5'48+%' .+0' &+#)4#/ NEMA 1 5ECNG 065 MLO

EX. EX.

TYP.

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

TYP.

$

TO UTILITY TRANSORMER

TO UTILITY TRANSORMER

EXISTING LOAD

': ' '.'%64+%#. 5'48+%' .+0' &+#)4#/ 5ECNG 065

8.

CONSTRUCTION DOCUMENTS ARE NOT CONSIDERED TO BE FOR CONSTRUCTION UNTIL REVIEWED AND APPROVED BY BOTH THE AUTHORITY HAVING JURISDICTION AND THE SERVING ELECTRICAL UTILITY. 9. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LAWS AND REGULATIONS ADOPTED BY THE AUTHORITY HAVING JURISDICTION. 10. BEFORE THE WORK WILL BE CONSIDERED COMPLETE AND ON A DAILY BASIS DURING CONSTRUCTION, ALL RUBBISH AND UNUSED MATERIALS MUST BE REMOVED AND THE PREMISES LEFT IN A CONDITION SATISFACTORY TO THE OWNER. ANY PROPERTY DISTURBED OR DAMAGED MUST BE RESTORED TO THEIR FORMER CONDITION WITHOUT COST TO THE OWNER.

LOAD CALCULATIONS PEAK DEMAND ON EXISTING "D" SERVICE PER LAST 12 MONTHS OF SRP. RECORDS = 73.8 KW * 2

[(73.8 KW)/(208V x 1.732)] x [125%/80% p.f.] = 320A PEAK DEMAND ON EXISTING "E" SERVICE PER LAST 12 MONTHS OF SRP. RECORDS = 71.80 KW

EXISTING EXISTING COND. COND. TO SES "D" TO SES "E"

%

NOTE: THIS IS THE COMBINED DEMAND OF ALL FIVE EX. METERS.

*

5ECNG 065

NEW SWITCHGEAR JMT ELECTRICAL MFG LLC 800A 208Y/120V 60HZ. 3 PH, 4 WIRE, NEMA 3R, RATED 65 KAIC, WALL MOUNTED.

3

3

BUS 800A SECTION 800A, 65 KAIC

4 NEW 30" PULL SECTION

X AFC = 30,891 AMP

X

X

NEW PNL "Z" DISCONNECT 240VAC, 3-POLE, 4 WIRE, FUSED, NEMA3R, 200A

EX. 100AF

EX. 100AF

EXISTING LOAD

EXISTING LOAD

EX. 200AF

EXISTING LOAD

EX. 100AF

EXISTING LOAD

0'9 '.'%64+%#. 59+6%*)'#4 .+0' &+#)4#/ 5ECNG 065

X

M

FUTURE 400AF PV PULLOUT (BACKFED)

NEW 400AF

EX. 200AF

NEW 400AF

EXISTING LOAD X 200A NEW MBC CHH3200H2X EX. EX.

11

4

4

400.0 (NEC) AMPS @ 208V 2 SETS 3-# 250 AWG CU THWN-2 1-# 250 AWG CU THWN-2 NTL 1-# 3 AWG CU THWN-2 GND 3" EMT CONDUIT 10 FT MAX.

2

E. PANEL 'LG' STATUS= NEW BUS RATING= 225A VOLTAGE= 208/120V SYSTEM= 3Ø, 4W MOUNTING= FLUSH NEMA RATING= 1 MAIN TYPE= M.C.B. AIC RATING= 10K AIC

1 3 5 7 9 11 13 15 17 19 21 23

1 2 2 2 2 1

LTG. - EAST CANOPY REC. - G14 - NORTH POS (2)

20

1.08

20

1.20

REC. - GEN./CONV. - NORTHWEST REC. - G14 - SOUTH POS (2)

20

0.60

20

1.20

REC. - GEN./CONV. - SOUTHWEST REC. - G15 - HEATED HOLDING CABINET

20

0.60

20

2.00

REC. - G15 - HEATED HOLDING CABINET

20

2.00

20

1.08

LTG. - WEST CANOPY

2

TV'S - WEST CANOPY

1

STRING LIGHTS - WEST CANOPY

3

IWH

3

20

2.16

20

0.60

20/2

PHASE A

PHASE B

PHASE C

2.28 1.95 1.10 2.20 1.20 3.44 2.72 2.52

4.24

2.08

FROM 'SES B'

4.24

0.00

PHASE TOTALS (KVA/Phase)

# 1. 2.

60-AMP MAIN BREAKER TO BE REPLACED WITH A 90-AMP MAIN BREAKER.

3.

NEW LOADS

4.

UPDATED CALCS

9.96

DEMAND LOADS MAY VARY FROM CONNECTED

-';'& 016'5

LOADS BECAUSE OF CODE DIVERSITIES.

Load Code

60-AMP SUBFEED BREAKER TO BE REPLACED WITH A 90-AMP BREAKER.

0 1 2 3 4 5 6 7 9 10 11

Connected KVA

31.53

Demand KVA

30.79

Exterior Lighting Interior Lighting Receptacles Special Loads Motors Kitchen (Commercial) HVAC Heating HVAC Cooling

0.00

0.00

9.91

11.66

88 85

Connected KVA

Load Summaries

Factor

0.00

1.25

2 4 6 8 10 12 14 16 18 20 22 24

20

REC. - GEN./CONVENIENCE NORTH

2

0.75

20

REC. - G9 - U.C. FREEZER

2

0.50

20

REC. - G8 - U.C. REFRIGERATOR

2

20

REC. - G6 - PREP. TABLE

2

0.60

20

REC. - CONV. - SOUTHEAST

2

20

WEST CANOPY - (2) BAF

4

0.72

20

WEST CANOPY - (1) BAF

4

20

EAST CANOPY - (2) BAF

0.72

20

EAST CANOPY - (1) BAF

4

2.16

20

4

TV'S - EAST CANOPY

2

2.16

20

REC. - BACK OF FASCIA WEST CANOPY

2

2.16

20

REC. - BACK OF FASCIA EAST CANOPY

2

1865 E 3RD ST SUITE B TEMPE, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

2.76

DESCRIPTION OF SUB-FEED 200A/3P PANEL XYZ

4

CIRCUIT NUMBERING BY POLE POSITION CIRCUIT BREAKERS FEEDING A/C EQUIPMENT

Connected AMPS

0.00

1.25

3.45

0.93

18.86

4.16

1.00

4.16

4.32 0.00

1.00 ***

0.00

0.00

1.00

0.00

0.00

1.00

0.00

ALL BREAKERS SHALL BE FULLY RATED

Phase amps (Connected)

0.00

0.00

1.00

0.00

0.00

1.25

0.00

0.00

1.56

0.00

Subtotals Largest Motor Largest AC Unit

31.53

4

Total KVA

31.53

0.25

0.00

0.00

0.25

0.00

4

83.00 82.58 97.16

Per Table 220.56 Larger of the two loads per NEC 220-60 Larger of the two loads per NEC 220-60 Phase amps (Demand) Phase (A) Phase (B) Phase (C)

30.79 0.00

Phase (A) Phase (B) Phase (C)

4

4.32

0.00

4

SHALL BE "HACR" RATED.

Demand AMPS Demand KVA

0.00

L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

STATUS= NEW MANUFACTURER= SIEMENS PANEL SERIES = TBD

(N) LIGHTING WEST CANOPY CIRCUIT #19

(N) 1P 20A

(N) TVs WEST CANOPY RECEPTACLES CIRCUIT #17

R1

(N) TVs EAST CANOPY RECEPTACLES CIRCUIT #20

R1

-

4

Spare Capacity (Amps) Spare Capacity Load (%)

4

5 5.55%

HIGH PHASE

30.79

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1 R1 BAF01

3

BAF01

(N) WEST CANOPY BAFs CIRCUIT #12, #14 BAF02

BAF01

CCT NO. 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41

BUS RATING = 225A VOLTAGE = 208/120V SYSTEM= 3Ø, 4W MOUNTING= SURFACE TRIM=DOOR-IN-DOOR NEMA RATING = 3R FEED THRU LUGS = YES

-

LOAD DESCRIPTION

MAIN RATING= 225A MAIN TYPE= M.C.B. AIC RATING = 10K FULLY/SERIES= FULLY BRANCH BREAKER TYPE= BOLT-ON

BKR SIZE

LOAD (KVA)

20

0.36

REC. - POLE A2

20

0.36

2

REC. - POLE A3

20

0.36

2

REC. - POLE B1

20

0.36

2

REC. - POLE B2

20

REC. - POLE B3

20

LOAD CODE 2

REC. - POLE A1

2

2

PHASE B

20

1.44

20

1.08

REC. - BACK OF FASCIA

20

0.72

0.30

PHASE C

LOAD (KVA) 8.30 6.30

6.66 8.66

8.30 6.30

6.66

LOAD DESCRIPTION

SPARE (FUTURE RESTROOMS)

BUSSED SPACE BUSSED SPACE BUSSED SPACE BUSSED SPACE BUSSED SPACE BUSSED SPACE BUSSED SPACE

0.00

BUSSED SPACE

0.00

BUSSED SPACE

BUSSED SPACE

0.00

BUSSED SPACE

0.00

BUSSED SPACE

0.00

BUSSED SPACE BUSSED SPACE

BUSSED SPACE

0.00

BUSSED SPACE

0.00

BUSSED SPACE

3

BUSSED SPACE

0.00 0.00

BUSSED SPACE

3

BUSSED SPACE

1.08

SPARE

BUSSED SPACE

3

BUSSED SPACE

0.36 1.44 0.72

BUSSED SPACE

3

RESTROOM SUB-PANEL

100/2

0.00

BUSSED SPACE

LOAD CODE

100/2

0.30

SPARE

BUSSED SPACE

0.00

BUSSED SPACE

DATE:

GROUND BUS (COPPER) = YES NEUTRAL BUS (COPPER) = YES IG GROUND BUS (COPPER) = NO SKIRT TYPE= NONE # SECTIONS= 1 LOCATION = SEE PLAN

BKR SIZE

0.36

0.36

20

LTG. - STARS CANOPY

2

4

8.66

0.36

MUSCO LTG. CONTROLS STARS CANOPY - (2) BAF

1

3

PHASE A

REVIEWED BY: BUS MATERIAL= COPPER

FEED TYPE = BOTTOM TERMINATIONS = 75°C CU

REV

BY

COMMENTS/CHANGES

DATE

CCT NO. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42

FEED THRU LOADS/PHASE (WHERE APPLICABLE) SUB-FEED BREAKER PHASE TOTALS (KVA/Phase)

(N) 1P 20A

(N) WEST CANOPY RECEPTACLES @ FASCIA CIRCUIT #22

R2

R2

R2

R2

R2

R2

(N) 1P 20A

(N) EAST CANOPY RECEPTACLES @ FASCIA CIRCUIT #24

R2

R2

R2

R2

R2

R2

51.#4 5*#&' %#012+'5 .+)*6+0) Ä 10' .+0' &+#)4#/

0 1 2 3 4 5 6 7 9 10 11

SYMBOL

LABEL

QTY.

L1

41

MANUFACTURER

DESCRIPTION

BEGHELLI

ILLUMINA BS100LED-RK

5ECNG Ä Ä

%#012+'5 (#05 #0& 4'%'26#%.'5 5%*'&7.'

(2) #10, (1) #10 GND, 3/4'' PVC

(N) STARS FIELD CANOPY RECEPTACLES CIRCUIT #19

R2

R2

SYMBOL

R2

L1 L1 L1 L1 L1

(N) LIGHTING SOCCER FIELD CANOPY (N) 1P 20A CIRCUIT #17

LABEL

QTY.

MANUFACTURER

DESCRIPTION

BAF01

5

BIG ASS FANS

14' ESSENCE

BAF02

3

BIG ASS FANS

12' ESSENCE

BAF02

R1

12

--

QUAD RECEPTACLE @ 24'' A.F.F.

R2

16

--

QUAD RECEPTACLE @ BACK OF FASCIA

2.

(N) SOCCER FIELD CANOPY BAFs CIRCUIT #15

3.

51%%'4 (+'.& 5*#&' %#012; .+)*6+0) Ä 10' .+0' &+#)4#/ 5ECNG Ä Ä

Load Summaries

0.00

0.00

0.00

16.34

8.46

10.1

Motors Kitchen (Commercial) HVAC Heating HVAC Cooling Non-Coincedental Loads Miscellaneous - Non Continuous Miscellaneous - Continuous

Connected AMPS

98

Demand AMPS

Factor 1.25

1.08

1.25

1.35

2.88

1.00

2.88

1.00

29.50

1.00 ***

1.44

0.00 0.00

1.00

0.00

0.00

1.00

0.00

0.00

0.00

0.00

1.00

0.00

1.25

0.00

1.56

Total KVA

34.90

0.00

4 4

0.00

Phase (A) Phase (B) Phase (C)

0.00

0.25

0.00

0.00

0.25

0.00 35.17

136.16 70.50 84.16

Phase amps (Demand)

0.00

0.00

4

Per Table 220.56 Larger of the two loads per NEC 220-60 Larger of the two loads per NEC 220-60

0.00

35.17

4

Phase (A) Phase (B) Phase (C)

0.00

1.44

35.46

SHALL BE "HACR" RATED. ALL BREAKERS SHALL BE FULLY RATED

Phase amps (Connected)

Demand KVA

29.50

Subtotals Largest Motor Largest AC Unit

CIRCUIT NUMBERING BY POLE POSITION CIRCUIT BREAKERS FEEDING A/C EQUIPMENT

97

0.00

Peak Demand per 220-87

DESCRIPTION OF SUB-FEED 200A/3P PANEL XYZ

34.9 35.17

Connected KVA

Exterior Lighting Interior Lighting Receptacles Special Loads

4

4

Spare Capacity (Amps) Spare Capacity Load (%)

-

4

HIGH PHASE

127 56% -

ELECTRICAL EQUIPMENT LABELING (APPLIES TO ALL PANELS) 1.

BAF02

Demand KVA

LOADS BECAUSE OF CODE DIVERSITIES.

%#012+'5 .7/+0#+4'5 5%*'&7.'

R2

Connected KVA

DEMAND LOADS MAY VARY FROM CONNECTED

Load Code

(N) 2P 20A

CCT NO.

1.44

20.29

MEASURED PEAK DEMAND (KW)

COMMENTS/CHANGES

LOAD CODE

5'5 $ #&&'& .1#&5 691 51.#4 5*#&' %#012;

(N) EAST CANOPY BAFs (N) 2P 20A CIRCUIT #16, #18

DATE

1.20

LOAD DESCRIPTION

1.00

Non-Coincedental Loads Miscellaneous - Non Continuous Miscellaneous - Continuous

PANELBOARD

(N) 1P 20A

(N) 1P 20A

BKR SIZE

Peak Demand per 220-87

L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

BAF01

DATE:

GROUND BUS (COPPER) = YES

DESIGNED BY:

(2) #10, (1) #10 GND, 3/4'' PVC

(E) 225A PANEL ''R1'' 120/208V VAC, 1Ø, 3W.

LOAD (KVA)

1.44 2.88

2.76

2.08

SUB-FEED BREAKER

5ECNG Ä Ä

(N) LIGHTING EAST CANOPY CIRCUIT #1

2

2

BUS MATERIAL= COPPER NEUTRAL BUS (COPPER) = YES IG GROUND BUS (COPPER) = NO SKIRT TYPE= NONE # SECTIONS= 1 LOCATION = EQUIP. ROOM

FEED TYPE = BOTTOM TERMINATIONS = 75°C CU

MEASURED PEAK DEMAND (KW)

5ECNG Ä Ä

(N) 1P 20A

LOAD CODE

MAIN RATING= 90A MAIN TYPE= M.C.B. AIC RATING = 10K FULLY/SERIES= FULLY BRANCH BREAKER TYPE= BOLT-ON

FEED THRU LOADS/PHASE (WHERE APPLICABLE)

5'5 $ 10' .+0' &+#)4#/ 56#45 (+'.& %#012;

(E) 225A PANEL ''LG'' 120/208V VAC, 3Ø, 4W.

3

TO 'RR1'

EXISTENT 2-1/2"C WITH (4)-#4/0CU., (1)-#4CU. GND.

90/3

5'5 # 10' .+0' &+#)4#/ 691 51.#4 5*#&' %#012;

(N) 2P 20A

X

EX. 100AF

X

EX. 200AF

X

EX. 100AF

X

EX. 40AF

TYP.

DISCONNECT AND REMOVE EXISTING METER AND TURN OVER TO UTILITY. PROVIDE JUMPERS (CU) ACROSS ALL METER C.T. AREAS AND PROVIDE BLANK COVERS ON OPENING. 2. UNDERGROUND SECONDARY FROM EXISTING UTILITY PAD MOUNTED TRANSFORMER TO BE DISCONNECTED AND REMOVED. 3. TAP ONTO EXISTING BUSS AND CONNECT NEW FEEDERS AS NOTED. PROVIDE ALL HI-POT TESTING, ETC. AS REQUIRED. 4. ALL DASHED LINES ARE INDICATING EXISTING EQUIPMENT. 5. REMOVE EXISTING MAIN BONDING JUMPER FROM EX. SWITCHGEAR. 6. NEW CONDUCTORS FROM UTILITY TRANSFORMER. 7. DISCONNECT AND REMOVE EXISTING EQUIPMENT. 8. INSTALL NEW LOAD DISCONNECT AND TAP INTO EXISTING GUTTER. 9. FEED EXISTING PANEL "A" FROM NEW DISCONNECT. REPLACE EXISTING CONDUCTORS WITH NEW AS SPECIFIED. 10. CONTRACTOR TO FIELD VERIFY EXISTING MULTIPLE BUILDING SERVICE GROUNDING ELECTRODE BONDING. IF NOT PRESENT, BOND GEC PER LARGEST SERVICE CONDUCTORS PER NEC 250.58. 11. CONTRACTOR TO REPLACE EXISTING BRANCH BREAKERS WITH EATON BRH TYPE BREAKER 22KAIC RATED.

4.

5.

ELECTRICAL EQUIPMENT, SUCH AS SWITCHBOARDS, PANELBOARDS, DISCONNECT SWITCHES, ENCLOSED CIRCUIT BREAKERS, INDUSTRIAL CONTROL PANELS, METERING ENCLOSURES AND MOTOR CONTROL CENTERS SHALL BE FIELD MARKED WITH AN ARC-FLASH HAZARD WARNING LABEL PER NFPA-70, SECTION 110.16. ELECTRICAL SERVICE EQUIPMENT SHALL BE LEGIBLY MARKED IN THE FIELD WITH THE MAXIMUM AVAILABLE FAULT CURRENT AND THE DATE THE FAULT CALCULATION WAS PERFORMED PER NFPA-70, SECTION 110-24. ALL SWITCHBOARDS AND PANELBOARDS SHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLY ORIGINATES PER NFPA-70, SECTION 408.4(B). PER NFPA-70, SECTION 408.4(A), EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT AND SPECIFIC PURPOSE OR USE. THE IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON THE FACE OR INSIDE OF THE PANEL DOOR IN THE CASE OF A PANELBOARD AND LOCATED AT EACH SWITCH OR CIRCUIT BREAKER IN A SWITCHBOARD. ELECTRICAL CONTRACTOR SHALL PROVIDE A LABEL/PLAQUE AT EACH PANEL, SWITCHBOARD, TRANSFORMER, ETC. INDICATING THE COLOR OF EACH CONDUCTOR INSTALLED PER PHASE BASED ON THE SERVING VOLTAGE AT THAT LOCATION.

ELECTRICAL PANEL SCHEDULES AND ONE-LINE

E-1.4

ELECTRICAL SERVICE REPLACEMENT 1865 E 3RD ST. TEMPE, AZ 85281 (602) 288-6732 (OFFICE) WWW.SCOUTSOLAR.COM

A, B -

NORTH

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

EXISTING LOAD

REMOVED METER

M

EX. METER WITH CURRENT TRANSFORMERS

5ECNG 065

ELECTRICAL SERVICE UPGRADE LOCATION: ______________________________________________________________ CONTRACTOR INFORMATION:

DESIGNED BY: REVIEWED BY: DATE: REV

BY

DATE

COMMENTS/CHANGES

________________________________________________________ BUILDING CODES ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING CODES AND STANDARDS. INTERNATIONAL BUILDING CODE, 2018 EDITION (IBC), AS AMENDED INTERNATIONAL ENERGY CONSERVATION CODE, 2018 EDITION (IECC), AS AMENDED INTERNATIONAL FIRE CODE, 2018 EDITION (IFC), AS AMENDED INTERNATIONAL MECHANICAL CODE, 2018 EDITION (IMC), AS AMENDED INTERNATIONAL PLUMBING CODE, 2018 EDITION (IPC), AS AMENDED NATIONAL ELECTRIC CODE, 2017 EDITION (NEC), AS AMENDED _______________________________________________________________ DESIGN PROFESSIONALS

SYMBOL LEGENDS:

X

,1$ .1%#6+10

_______________________________________________________________ PROJECT DATA

EX. PULL OUT SWITCH

9

NEW 3-# 4/0 AWG CU THWN-2 1-# 4/0 AWG CU THWN-2 NTL AFC = 1-# 3 AWG CU THWN-2 GND 11,359 AMP 2.5" EMT CONDUIT 120 FT EX. PNL "Z" 4 200A, 208V, 3-PHASE, 4-WIRE, 4 25KAIC NEMA 1 MCB

&

NEW 30" PULL SECTION

SRP NEW #

8

X (3) 200A J FUSE

X

3

CCT NO.

2

TRIM=DOOR-IN-DOOR NEMA RATING = 3R FEED THRU LUGS = NO LOAD LOAD BKR (KVA) DESCRIPTION SIZE

1.

TOTAL AMPERAGE NEEDED FOR NEW SERVICE = 320A + 311.4A = 631.4A

BUS 800A SECTION 800A, 65 KAIC

E. PANEL 'K1' STATUS= NEW BUS RATING= 225A VOLTAGE= 208/120V SYSTEM= 3Ø, 4W MOUNTING= SURFACE NEMA RATING= 1 MAIN TYPE= 225A M.C.B. AIC RATING= 10K AIC FEED THRU LUGS

BAF01

REVIEWED BY:

BY

225/3

LG

E. PANEL 'H2'

E. PANEL 'L1C'

(N) 1P 20A

DESIGNED BY:

REV

1

BUS RATING = 225A VOLTAGE = 208/120V SYSTEM= 3Ø, 4W MOUNTING= SURFACE

PANELBOARD

STATUS= NEW MANUFACTURER= TBD PANEL SERIES =

KEY NOTES:

NOTE: THIS IS THE COMBINED DEMAND OF ALL FIVE EX. METERS.

[(71.8 KW)/(208V x 1.732)] x [125%/80% p.f.] = 311.4A

':+56+0) 76+.+6; 64#05(14/'4 .+0' &+#)4#/

90/3

1865 E 3RD ST. TEMPE, AZ 85281 (602) 288-6732 (OFFICE) WWW.SCOUTSOLAR.COM

100/2

225/3

5'5 # #&&'& .1#&5 691 51.#4 5*#&' %#012;

E. PANEL 'R1' STATUS= NEW BUS RATING= 225A VOLTAGE= 208/120V SYSTEM= 3Ø, 4W MOUNTING= SURFACE NEMA RATING= 3R MAIN TYPE= M.C.B. MAIN RATING= 225A AIC RATING= 10K AIC

NEW ELECTRICAL SERVICE (METER CONSOLIDATION.

5

BUS 800A SECTION 800A, 65 KAIC

225/3

FROM 'SES B'

PHOTOVOLTAIC SYSTEM 122.10 KW DC/ 96.0 KW AC

BUS 800A SECTION 800A 65 KAIC

THE CONTRACTOR SHALL VISIT SITE TO VERIFY EXISTING CONDITIONS UNDER WHICH HE WILL BE OBLIGATED TO PERFORM THIS WORK. EXAMINE AND VERIFY LOCATIONS / ARRANGEMENTS OF EXISTING EQUIPMENT, STRUCTURES, ETC THAT MAY AFFECT THIS WORK. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF EQUIPMENT AND WIRING. REVIEW THE DRAWINGS OF OTHER TRADES TO AVOID CONFLICTS AND DETERMINE ROUGH IN LOCATIONS SO THAT EACH PIECE OF EQUIPMENT IS INSTALLED TO FUNCTION PER THE MANUFACTURERS SPECIFICATIONS. ALL MATERIALS PROVIDED BY THE CONTRACTOR SHALL BE NEW. REMOVED OR DAMAGED MATERIAL SHALL NOT BE REUSED FOR RELOCATED. WHERE THE WORD "OWNER" IS USED IT SHALL BE UNDERSTOOD TO REFER TO THE OWNER, ENGINEER, OR DESIGNATED REPRESENTATIVE. CONTRACTOR SHALL BE RESPONSIBLE FOR RETAINING THE CURRENT PROJECT DOCUMENTS AND SPECIFICATIONS ON SITE AT ALL TIMES DURING THIS CONSTRUCTION EFFORT. EXISTING EQUIPMENT NOT EXPLICITLY SHOWN ON THE DRAWINGS IS INTENDED TO BE "EXISTING TO REMAIN UNCHANGED, UNLESS OTHERWISE NOTED. VERIFY ALL EQUIPMENT LOAD CHARACTERISTICS, EXACT LOCATIONS AND ALL ROUGH-IN REQUIREMENTS PRIOR TO INSTALL. THESE DRAWINGS ARE BASED ON INFORMATION OBTAINED FROM EXISTING DRAWINGS, FIELD INVESTIGATIONS, AND INFORMATION PROVIDED BY THE OWNER. CONCEALED WORK OR ENERGIZED EQUIPMENT MAY NOT HAVE BEEN PHYSICALLY VERIFIED BUT IS BELIEVED TO BE ACCURATE, MINOR DEVIATIONS SHOULD BE ANTICIPATED. DURING THE COURSE OF CONSTRUCTION, CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE OWNER OF ANY DISCREPANCIES.

EXISTENT 1"C WITH (4)-#2CU., (1)-#8CU. GND.

TO 'M1B' DIST. PANELBOARD.

BUS 800A SECTION 800A 65 KAIC

1.

FROM E. 'M1B'

TO 'SES-B'

BUS 800A SECTION 800A, 65 KAIC

GENERAL NOTES

EX. SERVICE ENTRANCE "E" "IMAGE CRAFT 3041 E BROADWAY #16,22,23,24" SUN VALLEY ELECTRIC MFG G800A 208Y/120V 60HZ. 3 PH, 4 WIRE, NEMA 3R, RATED 65 KAIC, WALL MOUNTED.

NEW ELECTRICAL SERVICE (METER CONSOLIDATION.

EX. SERVICE ENTRANCE "D" "IMAGE CRAFT 3041 E BROADWAY #16,22,23,24" SUN VALLEY ELECTRIC MFG 800A 208Y/120V 60HZ. 3 PH, 4 WIRE, NEMA 3R, RATED 65 KAIC, WALL MOUNTED.

NOTE:

_________________________________________________________ PROJECT DESCRIPTION.

NORTH

THIS PROJECT CONSISTS OF THE INSTALLATION OF A NEW 800 AMPS SWITCHGEAR TO

FUSED SWITCH

'.'%64+#. 5;56'/ 5+6' 2.#0 5ECNG Ä

/'6'4 .+56 A B C

10

PER SRP AFC = X 6 37,979 AMP

D

SOCKET SOCKET

SOCKET

SOCKET

SOCKET

SOCKET

SOCKET

SOCKET

SOCKET

13 SOCKET

SOCKET

E F G

ELECTRICAL LINE DIAGRAM

E-2.0

A B C

D

H

E

F G H I

NOTE:

J

I J

#

': '.'%64+%#. '37+2/'06 '.'8#6+10 5ECNG Ä

$

0'9 '.'%64+%#. '37+2/'06 '.'8#6+10 5ECNG Ä

GENERAL ELECTRICAL SITE PLAN

E-1.0


Parking Design 1865 E 3RD ST SUITE B TEMPE, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

OWNER:

PARKING LOT RESTRIPPING

1.0

1865 E 3RD ST SUITE B TEMPE, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

NOTES:

A-1.3

DEVELOPER:

1.0

A-1.2

ACCESIBLE PARKING SPACES SHALL BE DESIGNATED AS RESERVED FOR PERSONS WITH DISABILITIES BY A SIGN SHOWING THE INTERNATIONAL WHEELCHAIR SYMBOL.

RESERVED PARKING

THE SIGN MUST HAVE THE MINUMUM VERBIAGE OF "RESERVED PARKING", INTERNATIONAL WHEELCHAIR SYMBOL AND TUCSON CITY CODE SEC. 20-220 THE SIGN PLATE SHALL BE A MINIMUM OF 12" X 24" WITH A THICKNESS OF 0.80 ALUMINUM CONSTRUCTION. THE SIGN PLATE SHALL HAVE A WHITE REFLECTIVE BACKGROUND WITH A BLUE LEGEND. (STANDARD 3M SCOTCHLITE SIGN FACE NUMBER R7-32 OR EQUIVALENT, WITH BLUE SCREEN PRINTED LETTER AS SHOWN ABOVE.)

PARKING LOT RESTRIPPING

PROJECT TEAM

ONE IN SIX COVERED ACCESIBLE SPACES SHALL BE DESIGNATED FOR HIGH PROFILE. UNLESS ALL SPACES ARE HIGH PROFILE SPACES AN ADDITIONAL SIGN DESIGNATING "VAN ACCESIBLE" SHALL BE INCLUDED. THE SIGNS SHALL BE ON A STATIONARY POST OR APPROVED WALL LOCATION. THESE SIGNS SHALL NOT BE OBSCURED.

EXISTING BUILDING

EXISTING BUILDING

THE BOTTOM OF THE SIGN(S) SHALL BE LOCATED NO LESS THAN FIVE (5) FEET OR MORE THAN SIX (6) FEET ABOVE THE GRADE (PARKING LOT SURFACE) AND SHALL BE VISIBLE DIRECTLY IN FRONT OF THE PARKING SPACE.

DESIGNED BY: REVIEWED BY: DATE: REV

EXISTING BUILDING

EXISTING BUILDING

EX. SERVICE ALLEY

PARKING LOT RESTRIPPING

#

8+%+0+6; /#2 5ECNG Ä /+.'

NORTH

ACCESIBLE HANDICAP PARKING SIGN MUST NEVER BE OBSCURED. SEE DETAIL A.1 (TYP.)

PARKING LOT RE-STRIPING LOCATION: ______________________________________________________________ PROJECT DESCRIPTION.

ONE-WAY DRIVEWAY LIMIT OF WORK

ONE-WAY DRIVEWAY EXISTING CARPORT CONTOUR

5 FT ACCESS AISLE REQUIRED. ACCESS AISLES LOCATED ON EITHER SIDE OF THE PARKING SPACE EXCEPT FOR ANGLED PARKING SPACES WITH SHALL HAVE ACCESS AISLES LOCATED ON THE PASSENGER SIDE OF THE PARKING SPACES. ACCESS SPACES MUST BE PROMINENTLY OUTLINED IN COLORS OR MATERIALS CONTRASTING FROM REGULAR PARKING SPACES. * 4" OUTLINE STRIPING REQUIRED (TRAFFIC YELLOW PREFERRED) * ACCESS AISLE SHALL BE CLEARLY MARKED (CROSSHATCHING STRIPES SPACE 2 FT O.C. PREFERRED)

4'' WIDE PAINTING 45 ANGLE PAINT STRIPING SIDE @ 2'-0" O.C.

INTERNATIONAL ACCESSIBLE SYMBOL REQUIRED, BLUE AND WHITE SYMBOLS PREFERRED. A SYMBOL CAN BE DISPLAYED WITHOUT BLUE BACKGROUND. ACCESSIBLE SIGN REQUIRED - MUST NEVER BE OBSCURED. RECOMMENDED LOCATION IS TO BE NO GREATER THAN 10 FEET FROM CURB. ONE OUT OF EVERY 6 SPACES SHALL BE VAN ACCESSIBLE AND HAVE A MINIMUM VERTICAL CLEARANCE OF 8 FT 2 INCHES AT GRADE UNDER CANOPIES. THE VERTICAL SIGN SHALL CONTAIN THE DESIGNATION "VAN ACCESSIBLE"

LIMIT OF WORK

CURB STOPS ARE REQUIRED WHERE SIDEWALKS ARE FLUSH WITH THE PARKING SPACES. CURB STOPS AT OTHER LOCATIONS ARE OPTIONAL. SEE PARKING AREA DIMENSION POLICES FOR ANGLED PARKING.

COMMENTS/CHANGES

WHERE A TOTAL OF 4 OR FEWER PARKING SPACES ARE PROVIDED, IDENTIFICATION OF ACCESSIBLE PARKING SPACES SHALL NOT BE REQUIRED. ACCESSIBLE PARKING SPACE DIMENSIONS SHALL BE MAINTAINED AND THE ACCESS AISLE SHALL BE PROVIDED.

#

ADA PARKING SITE PLAN

#&# 2#4-+0) &'6#+. 5ECNG Ä Ä

A-1.1

. ______________________________________________________________ CONTRACTOR INFORMATION

LIM IT OF W

OR K

EXISTING CARPORT CONTOUR

DATE

THIS PROJECT CONSISTS OF THE RE-STRIPING OF PART OF THE

LIMIT OF WORK

LIMIT OF WORK

BY

5ECNG 0 5

NOTES:

DATE: REV

#&# 2#4-+0) 5+)0 &'6#+.

5ECNG 0 5

REVIEWED BY:

PROJECT NAME:

COMMENTS/CHANGES

DATE

241215'& #&# 2#4-+0) 5+6' 2.#0

DESIGNED BY:

PROJECT DATA

BY

1865 E 3RD ST SUITE B TEMPE, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

______________________________________________________________ BUILDING CODES

LIMIT OF WORK

ONE-WAY DRIVEWAY

ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING CODES AND STANDARDS.

LIMIT OF WORK

LIMIT OF WORK

INTERNATIONAL BUILDING CODE, 2018 EDITION (IBC), AS AMENDED INTERNATIONAL FIRE CODE, 2018 EDITION (IFC), AS AMENDED CITY OF TUCSON/PIMA COUNTY OUTDOOR LIGHTING CODE CITY OF TUCSON UNIFIED DEVELOPMENT CODE LOCAL AMENDMENTS TO ABOVE CODES ______________________________________________________________ BUILDING DATA

LIMIT OF WORK

LIMIT OF WORK

EXISTING CARPORT CONTOUR

PARKING LOT RESTRIPPING

LIMIT OF WORK

ONE-WAY DRIVEWAY

DESIGNED BY: REVIEWED BY:

EX. SERVICE ALLEY

DATE: REV

BY

DATE

COMMENTS/CHANGES

6#$.' Ä . /+0+/7/ 07/$'4 1( /1614 8'*+%.'5 52#%'5 4'37+4'& LAND USE GROUP / CLASS

MOTOR VEHICLE PARKING REQUIRED

EXISTING BUILDING

EXISTING BUILDING

EXISTING BUILDING

241215'& 2#4-+0) #0#.+5;5 NUMBER OF PARKING SPACES REQUIRED FOR RELIGIOUS USE AREA = 9594.78 S.F NEW PARKING SPACES PROPOSED

NORTH

#%%'55 .#0' 5+6' 2.#0

NEW ADA SPACES NEW VAN ACCESSIBLE SPACES

5ECNG Ä Ä *

PER 2010 ADA Standards for Accessible Design Sections 208 & 502 Parking Spaces and Section 206 Accessible Route

ACCESS LANE SITE PLAN AND GN

NORTH

A-1.0

241215'& 2#4-+0) .16 4'564+22+0) &'6#+. 5ECNG Ä Ä

PARKING LOT RESTRIPING DETAILS

A-1.3


Structural Design

(#0 5%*'&7.'

B -

TAG

QTY.

DESCRIPTION

WEIGHT

BAF01

5

14' ESSENCE w/ 3' ET

96 LBS.

BAF02

3

12' ESSENCE w/ 3' ET

90 LBS.

® A -

A -

.7/+0#+4'5 5%*'&7.'

5*#&' 5647%674' % &+/'05+105 5ECNG Ä

TAG

QTY.

DESCRIPTION

WEIGHT

IBS01

41

ILLUMINA BS100LED-RF

10 LBS.

EXISTING BUILDING

1865 E 3RD ST SUITE B TEMPE, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

PHOTOVOLTAIC SYSTEM, 22.62 KW DC/ 18.00 KW AC

®

1865 E 3RD ST TEMPE, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

PHOTOVOLTAIC SYSTEM 122.10 KW DC/ 96.0 KW AC

®

GENERAL NOTES: 1. VERIFY EXTENSION TUBE LENGTH AND MOUNTING BRACKET WITH MANUFACTURER PRIOR TO ORDERING. 2. BOTTOM OF FANS SHALL BE AT LEAST 10' AFF. (EXCLUDING HAIKU) 3. FANS SHALL BE AT LEAST 2' AWAY, IN ALL DIRECTIONS, FROM POSSIBLE OBSTRUCTIONS. 4. FANS SHALL NOT BE MOUNTED WITHIN TWO TIMES THE FAN DIAMETER OF EXHAUST OR RETURN AIR INTAKES, AND SHALL NOT BE IN DIRECT LINE OF DISCHARGE OF HVAC EQUIPMENT. 5. EXTENSION TUBES 4' OR LONGER SHALL BE INSTALLED WITH GUY WIRES PER THE MANUFACTURER'S INSTALLATION REQUIREMENTS. (EXCLUDING HAIKU) 6. FANS SHALL BE AT THE SAME LEVEL OR HIGHER THAN RADIANT HEATERS AND OUTSIDE THE MINIMUM CLEARANCE TO COMBUSTIBLES. 7. FANS SHALL BE AT LEAST TWO AND ONE-HALF TIMES THE DIAMETER OF THE LARGEST FAN AWAY FROM NEIGHBORING FANS.

EXISTING BUILDING

DESIGNED BY: REVIEWED BY: DATE: REV

BY

COMMENTS/CHANGES

DATE

A -

%10%'267#. 5647%674#. 5'%6+10

#

NORTH

5ECNG Ä Ä

5;56'/ 5647%674#. 5+6' 2.#0 5ECNG Ä Ä

DESIGNED BY: REVIEWED BY: DATE: REV

BY

DATE

COMMENTS/CHANGES

PLAN VIEW

$

SIDE VIEW

ISOMETRIC VIEW

FRONT VIEW

70+4#% 4/ $#..#56 /1706 5;56'/ 8+'95

%

5ECNG 0 5

70+4#% 4/ $#..#56 /1706 5;56'/ &'6#+.5

&

5ECNG 0 5

411( /1706+0) 5;56'/ &'6#+.5

STRUCTURAL SITE PLAN AND DETAILS

5ECNG 0 5

S-1.0

D -

IRONRIDGE RAIL IRONRIDGE KO TILE

SOLAR PV MODULE

IRONRIDGE TILE REPLACEMENT FLASHING (S TILE)

ROOF ATTACHMENT, TYP.

J 5.4

51.#4 5*#&' 5647%674' # &+/'05+105 5ECNG Ä

51.#4 5*#&' 5647%674' $ &+/'05+105 5ECNG Ä

%

6;2+%#. (#0 /1706+0) &'6#+. Ä 2.#0 8+'9 5ECNG Ä Ä

&

H 5.4

C

VARIES

(#0 /1706+0) &'6#+. Ä +51/'64+% 5ECNG 0 5

NEW (36) LONGI LR4-60HPH-360M SOLAR MODULES FLUSH MOUNTED ON PITCHED ROOF FACING DUE SOUTH AT A 18 DEG. ANGLE.

S TILE ATTACHMENT DETAIL

MOUNTING RAIL, TYP.

SCALE: 1/8''-1'

IRONRIDGE STOPPER SLEEVE IRONRIDGE TILE REPLACEMENT IRONRIDGE UNIVERSAL FLASHING (S TILE) FASTENING OBJECT PV MODULE G E J 5.0 5.0 IRONRIDGE RAIL 5.4

IRONRIDGE KO TILE IRONRIDGE UNIVERSAL FASTENING OBJECT

1.0000

REFERENCE CERT LETTER GUIDELINES

STRUTURAL SITE PLAN

S TILE ATTACHMENT DETAIL

SCALE: 1/8''-1'

IRONRIDGE UNIVERSAL FASTENING OBJECT

PV MODULE FRAME IRONRIDGE UNIVERSAL FASTENING OBJECT

PV MODULE FRAME IRONRIDGE RAIL IRONRIDGE CAMO END CLAMP

PV MODULE FRAME

0.3750

IRONRIDGE RAIL

H

#

%10%'267#. 51.#4 5722146 5647%674' 5'%6+10 8+'9 5ECNG 065

$

%10%'267#. 5722146 5647%674' 5'%6+10 8+'9 5ECNG 065

NOTE: REFER TO SOLAR CANOPY STRUCTURAL PLANS FOR DETAILS.

STR - FAN AND LIGHTING LOCATION AND SPECS

S-1.0

DETAIL, MID CLAMP PLAN Scale: 6" = 1'-0"

J

ANALYSIS OF LAG-BOLT CONNECTIONS FOR UP-LIFT CALCULATION: LUMBER TYPE: DOUGLAS FIR 5 CONNECTOR TYPE: STAINLESS STEEL LAG SCREW 16 '' X 3 21'' ALLOWABLE WITHDRAWAL LOAD PER ATTACHMENT POINT: 258 LB/IN X 2 1/2 INCHES X 2 SCREWS= 1290 LBS (>216 LBS)

DETAIL, END CLAMP (CAMO) PLAN Scale: 6" = 1'-0"

K

DETAIL, MID CLAMP FRONT Scale: 6" = 1'-0"

SCALE: 1/8''-1'

PV MODULE, BY OTHERS

PV MODULE FRAME

IRONRIDGE RAIL

L

PV MODULE, BY OTHERS IRONRIDGE RAIL

IRONRIDGE RAIL IRONRIDGE REPLACEMENT FLASHING (S TILE)

IRONRIDGE CAMO END CLAMP

*MODULE GLASS NOT SHOWN FOR CLARITY

LOAD CALCULATIONS SOLAR MODULE: LONGI LR4-60HPH-360M 360W SOLAR MODULE DEAD LOAD: 69.09'' X 40.86'' @ 42.99 LBS = 2.19 PSF EA. ARRAY SQ.FT: 19.55 SQ.FT. PER MODULE = 703.8 SQ.FT. ARRAY RACKING DEAD LOAD: 1.00 LB/SQ.FT. ARRAY DEAD LOAD (RACKING INCLUDED): 2,245.12 LBS TOTAL ATTACHMENT POINTS: 70 TRIBUTARY DEAD LOAD PER ATTACHMENT (RACKING INCLUDED): 32.10 LBS WIND UPWARD PRESSURE (SEI/ASCE 7-10): 20.8 PSF WIND LOAD PER ATTACHMENT POINT: 216 PSF

L

IRONRIDGE REPLACEMENT FLASHING (S TILE)

KO TILE

DETAIL, END CLAMP (CAMO) FRONT Scale: 6" = 1'-0"

KO TILE (E) BUILDING STRUCTURE

(E) BUILDING STRUCTURE

CUSTOMER INFORMATION: OWNER

DESIGNED BY:

PROJECT INFORMATION PROJECT NAME 12.96 kW DC / 10.44 kW AC

4051 E YELLOWSTONE PL CHANDLER 85249 WWW.SONORASOLAR.NET

EMAIL: COMPANY:

-

PHONE NUMBER: -

NORTH

WEYRICK RESIDENCE

SCOTT AND LISA WEYRICK

ADDRESS:

4051 E YELLOWSTONE PL CHANDLER 85249 SONORA SOLAR ENGINEERING LLC

ADDRESS: 1865 E 3RD ST, SUITE B. TEMPE, AZ. 85281

STRUCTURAL SITE PLAN

PHOTOVOLTAIC SYSTEM SIZE

PROJECT ADDRESS CITY OF CHANDLER AUTHORITY HAVING JURISDICTION

SHEET NO.

S-1.0


Miscellaneous .')'0&

12/12/18

Page 1/4

EXISTING VEGETATION 1865 E 3RD ST SUITE B TEMPE, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

EX. LIGHTING FIXTURE

SCOUT SOLAR LLC REPORT: SAINT JEROME PV SYSTEM #2

NEW CANOPY LIGHTING FIXTURE

NEW CONDUIT ROUTING

GENERAL NOTES -

Grid-Connected System: Simulation parameters Saint Jerome Phoenix Sky Harbor Intl Ap

Country

Situation Time defined as

Latitude Legal Time Albedo Phoenix Sky Harbor Intl Ap

33.45° N Longitude Time zone UT-7 Altitude 0.20 NREL NSRD : TMY3 - TMY

Simulation variant :

ALL CONDUITS, MOUNTING BRACKETS, JUNCTION BOXES AND HARDWARE ALIKE ARE TO BE PAINTED TO MATCH COLUMNS AND BEAMS.

-

Geographical Site

Meteo data:

-

EX. BUILDING

LIGHT FIXTURES MUST BE FULLY CONCEALED BY PURLINS AND/OR BEAMS (TYP.)

-

PROPOSED LIGHT COLOR: 5000K (BLUE/WHITE)

-

ANY LIGHT FIXTURE WITH OUTPUT EQUAL TO OR GREATER THAN 2,600 INITIAL LUMENS SHALL NOT BE OPERATED BETWEEN 11:00 P.M. AND 6:00 A.M.

United States -111.98° W 337 m

3

)'0'4#. 016'5

4

1.

4 3 3

4

5. 4

6. NORTH

0'9 %#42146 2#4-+0) .#0&5%#2' #4'# +44+)#6+10 2.#0 5ECNG Ä

NORTH

0'9 %#42146 2#4-+0) .#0&5%#2' #4'# +44+)#6+10 2.#0 5ECNG Ä

-'; 016'5

DATE: REV

LIMIT OF WORK

BY

COMMENTS/CHANGES

DATE

EX. BUILDING EX. BUILDING

Collector Plane Orientation

Tilt

1.1 -

12/12/18 13h26

EX. BUILDING

1.1

Models used

Transposition

Horizon

Free Horizon

Near Shadings

No Shadings

User's needs :

Azimuth

Perez

Diffuse

COMMON NAME

PAKINSONIA HYBRID "DESERT MUSEUM"

PALO VERDE

15 GAL.

EX. BUILDING "D"

QUANTITY

SIZE

7

15 GAL.

EMITTER RAIN BIRD XM-10-6

OUTLET 6-1 GPH OUTLETS

1.2 -

NOTE: SLEEVING SHALL BE PROVIDED FOR ALL MAINLINE PIPE, LATERAL PIPE, CONTROL WIRING, AND DRIP LATERAL PIPE. COORDINATE WITH GENERAL CONTRACTOR FOR PLACEMENT UNDER PAVED SURFACES, TYP.

EX. BUILDING

EX. BUILDING

5+6' 016'5

In parallel Unit Nom. Power At operating cond. I mpp

10 strings 330 Wp 47.4 kWp (50°C) 87 A

Sub-array "Sub-array #2" Number of PV modules Total number of PV modules Array global power Array operating characteristics (50°C)

In series Nb. modules Nominal (STC) U mpp

17 modules 85 28.05 kWp 580 V

In parallel Unit Nom. Power At operating cond. I mpp

5 strings 330 Wp 25.17 kWp (50°C) 43 A

Nominal (STC) Module area

81 kWp 475 m²

NORTH

.+)*6+0) 5+6' 2.#0

5ECNG Ä

LIGHTING AND PHOTOMETRIC SITE PLAN

.+)*6+0) 5+6' 2.#0 5ECNG Ä

A-1.3

NORTH

)'0'4#. 5+6' 2.#0

2.

REMOVED AND PAVED PARKING LOT ISLAND LANDSCAPE AREAS = 4 ISLANDS OF 155 SQ.FT. TOTAL OF 620 SQ.FT. NO EXISTING VEGETATION ON ISLAND PARKING LOT AREAS TO BE REMOVED.

LANDSCAPE PLAN

5ECNG Ä

L-1.0

JAP6-72-330/3BB JA Solar

E. F. G. H. I. J.

245 modules 429 m²

HVAC

1865 E 3RD ST SUITE B TEMPE, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

DESIGNED BY:

Symo 20.0-3 / 480 Fronius USA 200-800 V Unit Nom. Power 2 * MPPT 0.57 Total Power Pnom ratio

Sub-array "Sub-array #2" : Inverter Model Custom parameters definition Manufacturer Characteristics Operating Voltage Inverter pack Nb. of inverters

Symo 24.0-3 / 480 / SC Fronius USA 200-800 V Unit Nom. Power 1 units Total Power Pnom ratio 3

Total Power

VAN

DESIGNED BY:

REVIEWED BY:

 VAN

Sub-array "Sub-array #3" : Inverter Model Custom parameters definition Manufacturer Characteristics Operating Voltage Inverter pack Nb. of inverters

1865 E 3RD ST SUITE B TEMPE, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

1865 E 3RD ST SUITE A TEMPE, AZ 85281 (602) 288-6732 (OFFICE) (815) 301-3164 (FAX) WWW.SCOUTSOLAR.COM

C. D.

GENERAL LIGHTING BESIDES SOLAR CANOPY LIGHTING REMOVED FROM SCOPE OF WORK. PROVIDED AND INSTALLED UNDER SEPARATE PERMIT. SITE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING ALL UTILITY COMPANIES TO VERIFY ALL CONDUIT ROUTINGS AND SIZES, EQUIPMENT LOCATIONS AND REQUIREMENTS, SCHEDULES, INSPECTIONS, ETC. SITE ELECTRICAL CONTRACTOR SHALL PROVIDE AS-BUILTS OF CONDUIT STUB-OUTS. ALL UNDERGROUND CONDUIT SHALL BE INSTALLED WITH DETECTABLE UNDERGROUND LOCATION DEVICE CAPABLE OF BEING DETECTED FROM ABOVE GROUND WITH AN ELECTRONIC LOCATING DEVICE. ALL EMPTY CONDUIT SHALL BE INSTALLED WITH PULL TAPE. DO NOT RUN CONDUIT SWEEPS THROUGH HEAVILY LANDSCAPED AREAS. NO CONDUITS SHALL BE ROUTED UNDER BUILDING PAD AREAS UNLESS BEING ROUTED TO THAT SPECIFIC BUILDING FOR SERVICE PURPOSES. ALL CONDUIT SHALL BE A MINIMUM OF 24'' BELOW GRADE. VERIFY ALL LOCATIONS OF CONDUIT STUBS LEADING INTO BUILDING PAD AREAS WITH THE OWNER PRIOR TO INSTALLATION. STAKE ENDS OF ALL STUBBED OUT CONDUIT WITH REBAR LOOP EXTENDING ABOVE GRADE. MINIMUM CONDUCTOR SIZE FOR EXTERIOR POWER AND LIGHTING SHALL BE #10CU., IN 34''C. THROUGHOUT THE ENTIRE LENGTH OF THE CIRCUIT UNLESS NOTED OTHERWISE.

SCOUT SOLAR LLC

A. B.

CHRIST'S CHURCH OF THE VALLEY - LAVEEN, AZ. PHOTOVOLTAIC SYSTEM 122.10 KW DC/ 96.0 KW AC

Total Cell area

GENERAL NOTES:

REVIEWED BY:

DATE: REV

BY

DATE

DATE: COMMENTS/CHANGES

REV

BY

DATE

COMMENTS/CHANGES

18.0 fc

VAN

15.0 fc

10.0 fc

5.0 fc

20.0 kWac 40 kWac 1.32

2.5 fc

2.0 fc



 

 PCS.

MANUFACTURER

41

24.0 kWac 24 kWac 1.17 64 kWac

ARTICLE NO.

  

 P

P

LUMINOUS EFFICACY

50.0 W

5671 lm

113.4 lm/W

ARTICLE NAME

-

BEGHELLI

BS100LED4HTLOWT40120V-277V-FL



 Properties

*

E

Emin

Emax

E/Emin

Emax/Emin

Calculation surface 1

4.80 fc

0.30 fc

18.0 fc

15.8

59.3

S1

Calculation surface 2

1.87 fc

0.009 fc

11.1 fc

218

1301

S2

Index

DIALux

 Model

Lenght

Efficacy

Consumption Wattage

Lumen Output

CRI

L70 (hrs.)

L85 (hrs.)

BS100LED4HTLOWT40120V-277V-FL

4 ft

113 lm/W

50

5,673

>80

>60,000

>50,000

Frequency (HZ)

DC Current (V)

DC Current (MA)

50/60

45

1000

Characteristics Electronic driver LED 4000 K Lumens per lamp Total Lamp Lumens Luminaire Lumens Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Total Luminaire Watts Ballast Factor CIE Type Spacing Criterion (0-180) Spacing Criterion (90-270) Spacing Criterion (Diagonal)

N.A. (absolute) N.A. (absolute) 6807 N.A. 113 60 1.00 Direct 1.22 1.26 1.36

 Product

BS100LED4HTLOWT40120V-277V-FL

Nominal Power (W)

50

AC Current (A) AC Voltage 120V 277V 0.43

0.18

PHOTOMETRIC ANALYSIS

PVsyst Licensed to Sonora Solar Engineering LLC (United States)

CONTRACTOR TO CONNECT NEW LATERAL TO EXISTING LATERAL. CONTRACTOR TO PROVIDE 14'' TUBING FROM LATERAL TO TREE. SEE EMITTER SCHEDULE.

COMMENTS/CHANGES

DATE

EMITTER SCHEDULE

Imported

16 modules 160 52.8 kWp 546 V

PV Array loss factors

PLANT EX. BUILDING

EX. BUILDING

Unlimited load (grid)

Nb. of inverters

EXISTING DRIP LATERAL: DRIP LATERAL SHOWN FOR GRAPHIC PURPOSES ONLY. CONTRACTOR TO VERIFY LOCATION, SIZE, AND CONDITION OF LATERAL BEFORE START OF CONSTRUCTION.

BY

EX. PARKING LOT

PV Arrays Characteristics (2 kinds of array defined) PV module Si-poly Model Original PVsyst database Manufacturer Sub-array "Sub-array #3" Number of PV modules In series Total number of PV modules Nb. modules Nominal (STC) Array global power Array operating characteristics (50°C) U mpp

Total

BOTANICAL NAME

1.

Arrays global power

EXISTING MAINLINE: MAINLINE SHOWN FOR GRAPHIC PURPOSES ONLY. CONTRACTOR TO VERIFY LOCATION, SIZE, AND CONDITION OF MAINLINE BEFORE START OF CONSTRUCTION.

DATE: REV

VEGETATION SCHEDULE

EX. BUILDING "C"

NORTH

Total

EXISTING DRIP VALVE: CONTRACTOR TO VERIFY LOCATION, SIZE, AND CONDITION OF MAINLINE BEFORE START OF CONSTRUCTION.

EX. BUILDING "A"

No 3D scene defined, no shadings 5°

-

System type

DESIGNED BY: REVIEWED BY:

REVIEWED BY:

EX. BUILDING

Simulation parameters

3. 4.

3 4

1

DESIGNED BY:

REFER TO EMITTER DETAILS FOR EMITTER SPECIFICATIONS, LAYOUT FOR PROVIDING DISTRIBUTION TUBING, QUANTITIES, AND LOCATION TO EACH PLANT. ADJUST IRRIGATION OPERATING TIMES TO ACCOMMODATE PLANT MATURITY, SOIL TYPE, PLANT EXPOSURE AND SEASONAL REQUIREMENTS. IRRIGATION DESIGN IS SCHEMATIC FOR GRAPHIC CLARITY, ALL EQUIPMENT SHALL BE IN PLANTING AREAS. CONTRACTOR IS TO NOTIFY LANDSCAPE ARCHITECT IF ANY SYSTEM ADJUSTMENTS ARE NECESSARY DUE TO UNKNOWN SITE CONDITIONS, PRESSURE DISCREPANCIES, ETC. APPROXIMATE LOCATION OF MAINLINE AND VALVES ARE SHOWN ON PLAN. FINAL LOCATION IS TO BE DETERMINED BY OWNER'S REPRESENTATIVE. AVOID LOCATING VALVES AND VALVE BOXES IN PLAN VIEW. INSTALL IRRIGATION MATERIAL/EQUIPMENT PER PLANS, DETAILS, NOTES AND MANUFACTURER'S SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE FOR COSTS AND LIABILITY RELATED TO WORK WHICH IS NOT PER DOCUMENTATION.

2.

Jerome Syst 2 variant 1 Simulation date

PARKING LANDSCAPE AREAS TO BE REMOVED AND PAVED FOR PARKING.

1

4

PHOTOVOLTAIC SYSTEM, 146.52 KW DC/ 100.00 KW AC

Project :

EXISTING LIGHTING CIRCUITS TO PANELBOARDS HAVE TIME CLOCKS AND LIGHTING CONTROLS. CONTRACTOR TO FIELD VERIFY THE TIME CLOCK ALLOW FOR THE CANOPY LIGHTS TO BE ON BETWEEN THE HOURS OF SUNSET AND SUNRISE.

3

3 1

1865 E 3RD ST SUITE B TEMPE, AZ 85281 (602) 499-8557 (OFFICE) WWW.SONORASOLAR.NET

NEW VEGETATION - TO BE PLANTED (SEE TREE SCHEDULE)

4

4

PHOTOVOLTAIC SYSTEM, 146.52 KW DC/ 100.00 KW AC

Sonora Solar Engineering LLC

PHOTOVOLTAIC SYSTEM, 146.52 KW DC/ 100.00 KW AC

PVSYST V6.77

LEGEND

E-1.5

IRRIGATION DETAILS

L-1.1


Permitting


Utilities

Authorities Having Jurisdiction


1865 E 3rd St, Suite B Tempe, AZ 85281 (602) 499-5775 info@ssolare.com www.ssolare.com

Contact Us



1865 E 3rd St, Suite B Tempe, AZ 85281 (602) 499-5775 info@ssolare.com ssolare.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.