OUR SERVICES
OUR office
Feasibility Sketches / Site Appraisals
STEN Architecture LTD
Master Planning
Suite 4, Unit 1
Residential Layouts
Benton Office Park
Land Promotion Documents
Bennett Avenue
Mixed Use Layouts
Horbury, Wakefield
Coordination Of Planning Applications
WF4 5RA
Design & Access Statements Bespoke Residential Design
01924 669424
Extensions & Conversions Conveyance / Legal Plans
Simon@sten-architecture.co.uk
Building Regulations Drawings
Ben@sten-architecture.co.uk
Applications
Stuart@sten-architecture.co.uk
High Quality Marketing & Sales Images
ABOUT US
STUART LINK BA (Hons) Dipl Arch ARB RIBA
20 Years Professional Experience
BEN SIMCOX BA (Hons) Dipl Arch
20 Years Professional Experience
STUART LINK BSC (Hons)
23 Years Professional Experience
As a RIBA Chartered Practice, STEN Architecture can offer all services associated with residential, commercial and mixed use developments ranging from concepts through to site supervision. Our philosophy is to create commercially successful developments within a framework of design flair, passion and professionalism. We are a modern, forward thinking practice that prides itself on strong client relationships, expertise and knowledge gained during each team members 15 years experience in the industry. STEN Architecture has the experience and commitment to deliver a comprehensive architectural and masterplanning service. Our highly motivated team of experts is also responsive and open-minded when collaborating with planners and consultants throughout the design process to ensure your project is functional, efficient, and cost-effective.
FRONT ELEVATION
PV orientated vertically - 992 (w) x 30mm between each / vertically 5m number and orientation to be determ
Roof ridge 9.368
vented roof tile for svp
First Floor Ceiling 5.998
Party wall line
1350
300
Eaves 5850
2100
First Floor 3133
Type A2 - obscured
First Floor Level 3.133
Ground Floor Ceiling 2.8
2100
Facing brick specification TBC
3133 FFL
For entrance canopy / porch see separate draw
Ground Floor 0
Type TBC Flush level access to meet M4(3) requirements
Feature b stack bon
FRONT ELEVATION
N xx
Type E
750
843
2400
1640mm (h) / horizontally mm between each. Exact mined by PV manufacturer
wing
DESCRIPTION:
2400
REV:
ARCHIT Type D
brickwork panel nded 440mm (w)
rwp For entrance canopy / porch see separate drawing by LGMH Architects Drawing Ref: LGMH0014-LGMH-GA-ZZ-DR-A-1058
STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985
CLIENT:
Legal & Ge
SITE:
Bonnington
REAR ELEVATION
Roof ridge 9.368
First Floor Ce
1350
Eaves 5850
Type A1
First Floor Lev
2025
First Floor 3133
Ground Floor
2175
Facing brick specification TBC
Ground Floor 0
Type B rwp
Flush level access to meet M4(3) requirements
REAR ELEVATION
P
Notes: xx
Party wall line
1350
300
eiling 5.998
vel 3.133
1800
Type A1
1350
Ceiling 2.843
REV:
DESCRIPTION:
BY:
DATE:
1050
Type A1
Patio Terrace Level
ASHP
ARCHITECTURE STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS
Web: www.sten-architecture.co.uk
Tel: 01924 950985
CLIENT:
Legal & General
SITE:
Bonnington Walk
Twitter: @STEN_arch Facebook: stenarchitectureltd Linkedin: Sten Architecture
SIDE ELEVATION
Roof ridge 9.368
35°
First Floo
Eaves 5850
First Floor 3133
First Floo
Ground F
Facing brick specification TBC windows * Optional for semi and end
terrace plots ( refer to site layout )
Ground Floor 0
9
SIDE ELEVATION
Notes: xx
or Ceiling 5.998
or Level 3.133
9553
*
1350
Floor Ceiling 2.843
REV:
DESCRIPTION:
BY:
DATE:
1050
Type A1
ARCHITECTURE Web: www.sten-architecture.co.uk
STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS
Twitter: @STEN_arch Facebook: stenarchitectureltd Linkedin: Sten Architecture
Tel: 01924 950985
CLIENT:
Legal & General
SITE:
Bonnington Walk Bristol
TITLE:
3B5PM4(3) Side Elevation
SCALE AT A3:
DATE:
DRAWN:
CHECKED:
GROUND FLOOR PLAN A
M4(2) COMPLIANCE KEY GROUND FLOOR -
Fire cavity barrier
1100
1585
6
Type B
328
SANITARY ACCOMMODATION ACCESS
970
Terrace consisting adjacent to externa
MAIN BATHROOM ACCESS ZONE, (REFER TO AD.M4(2) DIAGRAM 2.7A)
Dining 2843
450
10
KITCHEN
11 12 13 14 15 16
1048
729
Store 63
63
8
Hall
7
2843
1138
2100
MINIMUM 1200mm CLEAR SPACE IN FRONT OF AND BETWEEN ALL KITCHEN UNITS AND APPLIANCES.
9440
9
888
213
2
1
888
WC 2843
638
1538
3
rad.
rad.
888
cyl.
1273
850mm MIN CLEAR OPENING WIDTH TO FRONT DOOR
4
63
300mm WIDE x 1200mm LONG UNOBSTRUCTED SPACE TO LEADING EDGE OF ENTRANCE LEVEL DOORS
5 half height boxing stub stack
1200mm x 1200mm UNOBSTRUCTED ENTRANCE PLATFORM, WITH LEVEL ACCESS THRESHOLD, MINIMUM 900mm X 600mm COVERED ENTRANCE, ILLUMINATED
100
6
ENTRANCE LEVEL ACCESS
Store
LIVING ROOM WINDOW GLAZING TO BEGIN 850MM OR LOWER & WINDOWS EASY TO OPEN SWITCHES, SOCKETS, VENTILATION & SERVICE CONTROLS TO BE BETWEEN 450mm & 1200mm FROM FFL AND A MINIMUM OF 300mm FROM AN INSIDE CORNER. CONSUMER UNIT MOUNTED SO THAT SWITCHES ARE BETWEEN 1350 AND 1450 FROM FFL
347
DOORWAY & HALLWAY WIDTHS
850 min clear
327
THE MINIMUM CLEAR WIDTH OF EVERY HALL OR LANDING IS 900mm EVERY DOOR HAS A MINIMUM CLEAR OPENING WIDTH AS SET OUT IN TABLE 2.1
100
2155 rad.
100
FUTURE SHOWER 1000mm x 1000MM UNOBSTRUCTED ACTIVITY SPACE
Party wall
1100
736 100
350
3611
1000
1800
127
700
SANITARY FITTING UNOBSTRUCTED MANOEUVRING SPACE IN FRONT OF WC & WASH HAND BASIN
Fire cavity barrier
Type TBC 1468
1838 2188
For entrance canopy / porch see separate drawing by LGMH Architects Drawing Ref: LGMH 0014-LGMH-GA-ZZ-DR-A-1058
A
63
1023
6 1200mm x 1200mm unobstructed entrance platfor
GROUND FLOOR PLA
Notes: Gross Internal Floor Area 120.52 ROOM AREA (sq.m)
g of 150mm aggregate gravel strip al wall, then 3 x 450mm paving slabs 1500
Lounge 17.18 Kitchen / Dining 24.84 WC 2.56 Store (o/a) 2.86 Bedroom 1 12.34 Bedroom 2 12.43 Bedroom 3 9.83 Bedroom 4 9.83 Bathroom 4.57
1248 Type A1
1340
ASHP
328 rwp
WALL LEGEND.
328
2128 6942
1003
ASHP Hydrobox
DENOTES 150MM THICK LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD DRYLINING ON DABS WITH NOMINAL SKIM FINISH - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE BLOCKWORK - 12.5MM GYPROC WALLBOARD DRYLINING ON DABS WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT PLASTERBOARD ON DABS
3611
2843
2364
Kitchen
685
Type C1
2700
DENOTES 350MM THICK CAVITY WALL : - 102.5MM FACING BRICKWORK - 125MM WIDE CAVITY. 50MM AIRGAP THEN 75MM INSULATION - 100MM THICK 3.6N/MM² STANDARD AIRCRETE BLOCKWORK - 12.5MM PLASTERBOARD ON 10MM DABS WITH SKIM FINISH
DENOTES 93MM THICK NON LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - 63 X 38MM METAL STUDWORK AT 600MM CTRS. - 65MM ISOWOOL APR 1200 INSULATION - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT.
2700
3900 5052
1175
100
svp
DENOTES 93MM THICK NON LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - 63 X 38MM METAL STUDWORK AT 600MM CTRS. - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT.
888
DENOTES 370MM THICK PARTY WALL : - 25MM PLASTERBOARD ON DABS INTERNAL FINISH - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE CONCRETE BLOCKWORK - 100MM WIDE INSULATED CAVITY - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE CONCRETE BLOCKWORK - 25MM PLASTERBOARD ON DABS INTERNAL FINISH
3011
Living
FOR ALL MOVEMENT JOINT POSITIONS REFER TO STRUCTURAL ENGINEERS DRAWINGS 1248
Type A1
5074
ALL WALLS TO THE GROUND FLOOR WC AND PRINCIPLE BATHROOM (NOT EN SUITE) TO BE ABLE TO TAKE 1.5K/NM2. IF REQUIRED PATTRESS THE STUD WALLS ON THE WET ROOM SIDE FOR FIXING OF FUTURE FIXTURES SUCH AS GRAB RAILS.
2843
1453 327 100
1360
1698
CEILING HEIGHT
REV:
rad.
3475 Type D
2843
rwp
675
327
DESCRIPTION:
BY:
DATE:
ARCHITECTURE Web: www.sten-architecture.co.uk
STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS
Twitter: @STEN_arch Facebook: stenarchitectureltd Linkedin: Sten Architecture
Tel: 01924 950985
CLIENT:
Legal & General
SITE:
Bonnington Walk Bristol
TITLE:
4B6PM4(2) Ground Floor Plan
6943
rm
AN
SCALE AT A3:
1:50 PROJECT NO:
DATE:
20.10.2020 DRAWING NO:
DRAWN:
CHECKED:
SD REVISION:
M4(3) COMPLIANCE KEY FIRST FLOOR -
SANITARY ACCOMMODATION ACCESS SANITARY FITTING UNOBSTRUCTED MANOEUVRING SPACE IN FRONT OF WC & WASH HAND BASIN
MAIN BATHROOM TO BE 2600 x 2200 OR 2450 x 2450. (REFER TO AD.M4(3) DIAGRAM 3.15)
THE MINIMUM CLEAR WIDTH OF EVERY HALL OR LANDING IS 1050mm EVERY DOOR HAS A MINIMUM CLEAR OPENING WIDTH OF 850mm. CLEAR TURNING CIRCLE OF 1500mm DIAMETER WHEN THE DOOR IS CLOSED. LIVING ROOM WINDOW GLAZING TO BEGIN 850MM OR LOWER & WINDOWS EASY TO OPEN 740
Fire cavity barrier
A
1248 3510 Type A1
rad.
Bedroo
2991
2865
FUTURE SHOWER 1200mm x 1200MM UNOBSTRUCTED ACTIVITY SPACE 63
1987 11
BEDROOMS
12 13 14 15 16
8 7
loft hatch
6 5
4
3
2
137
Party wall 2295
8897
9
1
Land
Store / Future Lift provision with removeable floor
2235
1929 Towel
232
1113
1187
2865
1010
Bathroom 2865
svp
half height boxing 1050mm high
328
THE CEILING STRUCTURE TO EVERY BEDROOM IS TO BE STRONG ENOUGH TO ALLOW FOR THE FITTING OF AN OVERHEAD HOIST CAPABLE OF CARRYING A LOAD OF 200KG.
1010
10
63
MINIMUM 1000mm WIDE ACCESS FROM THE DOORWAY TO THE WINDOW. PRINCIPAL BEDROOM TO HAVE MINIMUM 1000mm WIDE ACCESS TO BOTH SIDES AND FOOT OF BED. OTHER DOUBLE BEDROOMS TO HAVE A MINIMUM 1000mm ACCESS TO ONE SIDE AND FOOT OF BED. SINGLE BEDROOMS TO HAVE MINIMUM 1000mm ACCESS TO ONE SIDE OF BED. EVERY BEDROOM TO HAVE 1200 x 1200 CLEAR MANOEUVRING SPACE
63
700
1100
DOORWAY & HALLWAY WIDTHS
327
FIRST FLOOR PLAN
Fire cavity barrier
3210 1772
Type A2 - obs 1248
A
Notes:
SWITCHES, SOCKETS, VENTILATION & SERVICE CONTROLS CENTRES TO BE BETWEEN 450mm & 1200mm FROM FFL AND A MINIMUM OF 300mm FROM AN INSIDE CORNER. CONSUMER UNIT MOUNTED SO THAT SWITCHES ARE BETWEEN 1350 AND 1450 FROM FFL
Gross Internal Floor Area 124.26 ROOM AREA (sq.m) Lounge / Kitchen / Dining 41.35 WC 3.51 Store (o/a) 3.20 Bedroom 1 15.62 Bedroom 2 14.32 Bedroom 3 10.26 Bathroom 6.83 Storage (o/a) 3.67
WALL LEGEND.
A 1248
63
1453
3497 Type A1
DENOTES 350MM THICK CAVITY WALL : - 102.5MM FACING BRICKWORK - 125MM WIDE CAVITY. 50MM AIRGAP THEN 75MM INSULATION - 100MM THICK 3.6N/MM² STANDARD AIRCRETE BLOCKWORK - 12.5MM PLASTERBOARD ON 10MM DABS WITH SKIM FINISH
328 rwp 328
2710
rad.
DENOTES 150MM THICK LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD DRYLINING ON DABS WITH NOMINAL SKIM FINISH - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE BLOCKWORK - 12.5MM GYPROC WALLBOARD DRYLINING ON DABS WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT PLASTERBOARD ON DABS
om 3
4432 63
DENOTES 93MM THICK NON LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - 63 X 38MM METAL STUDWORK AT 600MM CTRS. - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT.
2865
959
ALL WALLS TO THE GROUND FLOOR WC AND PRINCIPLE BATHROOM (NOT EN SUITE) TO BE ABLE TO TAKE 1.5K/NM2. IF REQUIRED PATTRESS THE STUD WALLS ON THE WET ROOM SIDE FOR FIXING OF FUTURE FIXTURES SUCH AS GRAB RAILS.
836
Store
26 1104
1200
FOR ALL MOVEMENT JOINT POSITIONS REFER TO STRUCTURAL ENGINEERS DRAWINGS
1285 208
2843
4403
1010
1010
DENOTES 370MM THICK PARTY WALL : - 25MM PLASTERBOARD ON DABS INTERNAL FINISH - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE CONCRETE BLOCKWORK - 100MM WIDE INSULATED CAVITY - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE CONCRETE BLOCKWORK - 25MM PLASTERBOARD ON DABS INTERNAL FINISH
9553
63
172 761
cyl. Store
ding
CEILING HEIGHT
REV:
DESCRIPTION:
BY:
DATE:
2530
270
Bedroom 2
ARCHITECTURE
rad.
2865
Web: www.sten-architecture.co.uk
STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS
Twitter: @STEN_arch Facebook: stenarchitectureltd Linkedin: Sten Architecture
Tel: 01924 950985
CLIENT:
Legal & General
SITE:
Bonnington Walk Bristol
TITLE:
3B5PM4(3) First Floor Plan
328
scured
A
Bedroom 1
270
513
90
h
DENOTES 93MM THICK NON LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - 63 X 38MM METAL STUDWORK AT 600MM CTRS. - 65MM ISOWOOL APR 1200 INSULATION - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT.
3797 63 7070
1678
rwp 328
Type E
1248
1453
SCALE AT A3:
1:50
DATE:
20.10.2020
DRAWN:
SD
CHECKED:
steel beam within floor zone to carry floor joists
FIRST FLOOR JOIST PLAN
stairwell
1187
63
trimmer
Party wall
2295
1695
removeable floor to lift void infill 1695
2298
trimmer
bath svp
sink
toilet
Floor joists to be Mitek Posi-Joist PS10 253mm deep
Dashed lines indicate first floor studwork
cyl.
GROUND FLOOR SERVICES PLAN A Fire cavity barrier
Terrace consisting of 150mm adjacent to external wall, then
Type B
Party wall
Dining
rad. 10
2
11 12 13 14 15 16
Store
9
8
Hall
7
2
S
6
5
4
3
2
1
half height boxing stub stack
rad.
DES U rad.
WC
cmev
Store 2
SP EV
Fire cavity barrier For entrance canopy / porch see separate drawing by LGMH Architects Drawing Ref: LGMH 0014-LGMH-GA-ZZ-DR-A-1058
Type TBC
A
PIR
cyl.
1200mm x 1200mm unobstructed entrance platform
GROUND FLOOR PLAN
m aggregate gravel strip n 3 x 450mm paving slabs
ASHP
Type A1
Electrical Symbols Legend
rwp
mounted 700-1000 above f.f.l. mounted 700-1000 Twin switched socket outlet 13A above f.f.l. mounted 700-1000 Twin switched socket outlet 13A above f.f.l. with USB port mounted 700-1000 Twin switched socket outlet 13A above f.f.l. Fused switch to bar heater / cooker hood / stair lift / thro' floor lift / alarm & extract fans (N) = Neon indicator mounted between Consumer unit 1350-1450 above f.f.l. 13A socket in separately appliance space switched mounted 700-1000 Cooker & Hob 32A isolator above f.f.l. Twin switched socket outlet 13A
ASHP Hydrobox U
Type C1
U
CU
Kitchen
Thermostat
H Towel/Rad
Towel heater / Radiator Low energy pendant lamp Low energy LED ceiling recessed spotlight
PIR
2
svp S H
Energy efficient external PIR flood light (with integral photocell to front entrance) mounted 700-1000 Switch above f.f.l. mounted 700-1000 2 way Switch above f.f.l. Mains powered fully automatic smoke detector. To be linked to AOV window on top floor if in circulation space Heat detector Intercom
DES MP
cmev
Door Entry System Media plate (inc tv, 2x sat, 2xRJ45, 2xDbl skts) Vent Axia MVDC-MS A whole house extract system ceiling mounted
mounted 700-1000 above f.f.l.
U
Ceiling mounted extract fan linked to whole house extract SP
Solar Panel control panel
EV
EV control panel
Note dimensions shown are to u/s of electrical plate Type A1
S
MP
Living
rad.
Type D
rwp
A SUITABLE NUMBER (AT LEAST ONE ON EACH FLOOR) OF SELF CONTAINED SMOKE ALARMS MUST BE INSTALLED. THE ALARMS SHOULD BE INTERCONNECTED AND FIXED TO THE CEILING IN A CENTRAL POSITION BUT AT LEAST 300MM FROM ANY LIGHT FITTING. THE ALARM MUST BE FIXED STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS.
FIRST FLOOR SERVICES PLAN A Fire cavity barrier
Type A1
MP
rad.
Bedroom 3
11
12 13 14 15 16
10
S
9
7
loft hatch 5
4
3
2
cyl. Store
137
6 1
Landing
1113
Party wall
8
Store / Future Lift provision with removeable floor
2 Towel
svp
Fire cavity barrier
rad.
Bathroom
half height boxing 1050mm high
Type A2 - obscured
A
FIRST FLOOR PLAN
Type A1
P
rwp
Electrical Symbols Legend
rad.
mounted 450-1200 above f.f.l. mounted 450-1200 Twin switched socket outlet 13A above f.f.l. mounted 450-1200 Twin switched socket outlet 13A above f.f.l. with USB port mounted 450-1200 Twin switched socket outlet 13A above f.f.l. Fused switch to bar heater / cooker hood / stair lift / thro' floor lift / alarm & extract fans (N) = Neon indicator mounted between Consumer unit 1350-1450 above f.f.l. 13A socket in separately appliance space switched mounted 450-1200 Cooker & Hob 32A isolator above f.f.l. Twin switched socket outlet 13A
DES
U U
CU
Bedroom 1
Thermostat Towel/Rad
Towel heater / Radiator Low energy pendant lamp Low energy LED ceiling recessed spotlight
PIR
2
S H
Store
Energy efficient external PIR flood light (with integral photocell to front entrance) mounted 450-1200 Switch above f.f.l. mounted 450-1200 2 way Switch above f.f.l. Mains powered fully automatic smoke detector. To be linked to AOV window on top floor if in circulation space Heat detector Intercom
DES MP
cmev
Door Entry System Media plate (inc tv, 2x sat, 2xRJ45, 2xDbl skts) Vent Axia MVDC-MS A whole house extract system ceiling mounted
mounted 450-1200 above f.f.l.
Ceiling mounted extract fan linked to whole house extract SP
Solar Panel control panel
EV
EV control panel
Note dimensions shown are to u/s of electrical plate A SUITABLE NUMBER (AT LEAST ONE ON EACH FLOOR) OF SELF CONTAINED SMOKE ALARMS MUST BE INSTALLED. THE ALARMS SHOULD BE INTERCONNECTED AND FIXED TO THE CEILING IN A CENTRAL POSITION BUT AT LEAST 300MM FROM ANY LIGHT FITTING. THE ALARM MUST BE FIXED STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS.
Bedroom 2
Type E
rwp
FOUNDATION PLAN
2100
100
Party wall
3611
327
A
sleeper wall
100
1901
shower
2874
toilet
WC
stub stack
sink
328
Store
3368
A
N xx
internal water supply
foul drain discharge
327 rwp 328
6942
Periscopic Venti
stub stack
washing machine
dual sink floor socket
dish washer
Air brick within foundation wall
100
3611
Beam & block floor span indicated. Floor to be supplied by specialist subcontractor
svp
5074
Beam & block floor span indicated. Floor to be supplied by specialist subcontractor
327
REV:
3475 100
rwp
328
DESCRIPTION:
ARCHIT STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985
CLIENT:
Legal & Ge
SITE:
Bonnington
SECTION AA
Roof void
Type A2 - obscured
1350
300
35°
Indicative roof structure, to be designed by specia
2100
5850
Bathroom
Store / Future lift provision
Removable floor for future lift provision
2100
FRONT
Type TBC
Front door heads +02.100
WC
Store / Future lift provision
90mm Kingspan Kooltherm K103 DPM
70mm screed
0
DPC
Psi-block EPS Infill block 150mm BT02 Bison Jetfloor
Foundations and ground floor to Structural Engineer design and detail.
SECTION A-A traditional style
Notes xx
Ridge Height +09.414
trusses alist.
220
42°
Finished floor level at first floor +03.133
196
Bedroom 3
253
Landing
3133
Type A1
2902 Structural
2865 Clear
Ceiling level at first floor +05.998 Window head heights at first floor +05.550
Type A1
3133 Floor to Floor
2858 Structural
2843 Clear
Window heads at ground floor +02.400
REAR
REV:
Store
Kitchen
DPC
Finished floor level at ground floor +00.000
Telescopic ventilator
Min. 150mm ventilated void.
DPC
DESCRIPTION:
ARCHITE STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985
CLIENT:
Legal & Genera
SITE:
Bonnington Wa Bristol
TITLE:
3B5PM4(3) Section Throug
SCALE AT A3:
1:50 PROJECT NO:
DATE:
01.12.2020 DRAWING NO:
ROOF PLAN
3600
Roof truss span direction 35° pitch
Party Wall
726
Roof truss span direction 35° pitch
Fire rated Spandrel Panel
ROOF PLAN Closed fasc
1
ridge line
1
Closed fasc
N xx
Timber roof truss design by Specialist Sub-contractor
cia
Bedrooms c bedroom to allow for the overhead h carrying a lo
rwp
Dry verge
100 x 75 timber wallplate
8785
svp to tile vent on flexible duct through roof space
loft hatch 562
2850
REV:
ARCHIT STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS
100 x 75 timber wallplate
cia
DESCRIPTION:
rwp
Tel: 01924 950985
CLIENT:
Legal & Ge
SITE:
Bonnington Bristol
TITLE:
4B6PM4(2) Roof Plan
BATHROOM PLANS & ELEVATIONS
half height boxing stub stack
half height boxing stub stack
D
A C
B
A B C Ground Floor WC
850-1000 above FFL
D
Elevation A
Ground Floor WC
Elevation A
half height boxing
First Floor Bathroom
450
1200 above FFL
700 to easy use flush
1050
Towel
400-712 clear zone max 400 to top of pan 770-850 floor to rim
1050
B
450
Elevation A
770-850 floor to rim
Shaver point
First Floor Bathroom
Towel
B 1200 above FFL
C
Shaver point
400-712 clear zone
A
max 400 to top of pan
C
svp
700 to easy use flush
D D
Elevation B
svp
half height boxing
A
E
Elevation A Elevation
Elevation D
1050
700 to easy use flush 1050
max 400 to top of pan
700 to easy use flush
400-712 clear zone
Elevation C
max 400 to top of pan
400-712 clear zone
770-850 floor to rim
770-850 floor to rim
850-1000 above FFL
Elevation B
Elevation D
Elevation C
REV
REV:
DESCRIPTION:
Bath
Elevation Bath B B
Elevation C
A
Elevation D
Elevation C Elevation D
ST Th Ha W W
ARCHI
Te STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS CLIEN Tel: 01924 950985
Legal &
CLIENT:
SITE:
TITLE
SITE:
Bonning Bristol
TITLE:
4B6PM4 WC &PROJ B
SCAL
SCALE AT A3:
1:50 PROJECT NO:
Trad-LGMH
Tr DA
21
DR
H
GROUND FLOOR EXTERNAL WALL DETAIL
OV Wall Thickness 327.5
102.5mm facing brick
103
125
100
13
100mm (10.4kN first floo
13
Floor ins wall bloc Approve type a 12.5mm 8kg/m.s
75mm Kingspan K108 (50mm clear cavity as NHBC requirements) Airgap (50mm)
75mm K clear ca requirem
25mm p provide 0.8M2K
DPC min 150mm above ground Periscope underfloor ventilator Ensure Grade 2 water proofing is achieved where flush level access is required to perimeter of building
Floor ins wall bloc
Finished floor level at Ground Floor +00.000
EPS infill block PSI Block
Foundations TBC by engineer
GROUND FLOOR EXTERNAL WALL DETAIL
L
Celcon Aircrete Blockwork N to ground floor, 7.3kN to or)
sulation to tightly abut ckwork ed document e wall ties
m plasterboard ( nominal sq ) mounted on dabs
Kingspan K108 (50mm avity as NHBC ments)
perimeter insulation to minimum resistance of K/W
sulation to tightly abut ckwork FFL +00.000
Floor finish varies
70mm screed on slip sheet 90mm Kingspan Kooltherm K103 insulation DPM
BISON Jetfloor Oversite
Minimum 150mm air void
REV:
DESCRIPTION:
ARCHITE STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985
CLIENT:
Legal & Gene
EXTERNAL WALL FIRST FLOOR JUNCTION OV Wall Thickness 327.5 103
125
100
13
13
102.5mm facing brick 75mm Kingspan K108 (50mm clear cavity as NHBC requirements) Airgap (50mm)
253mm Mitek Posi-Joists, trimmers, restraints etc to manufacturers details Finnseal insulated closer or similar to manufacturers details
TYPICAL FIRST FLOOR JUNCTION DETAIL
N DETAIL 100mm Celcon Aircrete Blockwork (10.4kN to ground floor, 7.3kN to first floor) Floor insulation to tightly abut wall blockwork Approved document e wall ties type a 12.5mm plasterboard ( nominal 8kg/m.sq ) mounted on dabs
MDF skirting board
REV:
DESCRIPTION:
ARCH STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985
CLIENT:
Legal &
ROOF EAVES DETAIL
Concrete roof tile 'Sandtoft' TLE Dark / Light Grey subject to Planning Proprietary roof tile vent (flush fitting) into interlocking concrete roof tiles ( indicative position ) Proprietary cross flow ventilator to maintain min 25mm air gap Breathable membrane Timber battens 300mm layer of type 5u roofing underlay rolled into gutter. for profile tiles use proprietary eaves filler Timber tilt fillet
Fascia to be specified by client
12.5mm plaste
100 x 75 timbe 1538 from top underside of w
12.5mm plaste 8kg/m.sq ) mo
Approved Doc Type A wall tie 103
125 O/A Wall Thickness 327.5
100
13
13
er wallplate set at of beam & block to wallplate
35°
erboard ceiling
400mm of roll insulation laid between rafters and then laid at 90°
Timber truss design by Specialist Sub-Contractor
REV:
DESCRIPTION:
erboard ( nominal ounted on dabs
cument E es
ARCH STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985
CLIENT:
Legal
SITE:
Bonni Bristo
TITLE:
Tradit
ROOF RIDGE & WINDOW REVEAL DETAIL
Ridge tile Ridge tile batten Roof membrane cut short at top by 25mm to allow for air flow
Concrete roof tile 'Sandtoft' TLE - Dark / Light Grey subject to Planning Timber batten Proprietary roof tile vent (flush fitting) into interlocking concrete roof tiles
Breathable membrane Prefabricated truss
Timber roof truss desgin by specialist sub-contractor
RIDGE DETAIL
Flexible SVP connection to vented roof tile
OV Wall Thickness 327.5 103
125
100
13
100mm Celcon Aircrete Blockwork (10.4kN to ground floor, 7.3kN to first floor)
13
102.5mm facing Brickwork - subject to Planning
12.5mm plasterboard ( nominal 8kg/m.sq ) mounted on dabs
75mm Kingspan K108 (50mm clear cavity as NHBC requirements)
150mm cavity Dritherm 37 insulation
DPC cavity tray with stop ends to all window/door openings. All as NHBC 6.1.17
Lintel to Structural Engineers specification
Weepholes at 450mm ctrs 100mm reveal
HEAD 100
UPVC Grey RAL 7016 Casement window. Refer to STEN Architecture Window Schedule
Cill
CILL Insulated cavity closer
WINDOW REVEAL DETAIL