Detatched Working Drawings

Page 1


OUR SERVICES

OUR office

Feasibility Sketches / Site Appraisals

STEN Architecture LTD

Master Planning

Suite 4, Unit 1

Residential Layouts

Benton Office Park

Land Promotion Documents

Bennett Avenue

Mixed Use Layouts

Horbury, Wakefield

Coordination Of Planning Applications

WF4 5RA

Design & Access Statements Bespoke Residential Design

01924 669424

Extensions & Conversions Conveyance / Legal Plans

Simon@sten-architecture.co.uk

Building Regulations Drawings

Ben@sten-architecture.co.uk

Applications

Stuart@sten-architecture.co.uk

High Quality Marketing & Sales Images


ABOUT US

STUART LINK BA (Hons) Dipl Arch ARB RIBA

20 Years Professional Experience

BEN SIMCOX BA (Hons) Dipl Arch

20 Years Professional Experience

STUART LINK BSC (Hons)

23 Years Professional Experience

As a RIBA Chartered Practice, STEN Architecture can offer all services associated with residential, commercial and mixed use developments ranging from concepts through to site supervision. Our philosophy is to create commercially successful developments within a framework of design flair, passion and professionalism. We are a modern, forward thinking practice that prides itself on strong client relationships, expertise and knowledge gained during each team members 15 years experience in the industry. STEN Architecture has the experience and commitment to deliver a comprehensive architectural and masterplanning service. Our highly motivated team of experts is also responsive and open-minded when collaborating with planners and consultants throughout the design process to ensure your project is functional, efficient, and cost-effective.


FRONT ELEVATION

PV orientated vertically - 992 (w) x 30mm between each / vertically 5m number and orientation to be determ

Roof ridge 9.368

vented roof tile for svp

First Floor Ceiling 5.998

Party wall line

1350

300

Eaves 5850

2100

First Floor 3133

Type A2 - obscured

First Floor Level 3.133

Ground Floor Ceiling 2.8

2100

Facing brick specification TBC

3133 FFL

For entrance canopy / porch see separate draw

Ground Floor 0

Type TBC Flush level access to meet M4(3) requirements

Feature b stack bon

FRONT ELEVATION


N xx

Type E

750

843

2400

1640mm (h) / horizontally mm between each. Exact mined by PV manufacturer

wing

DESCRIPTION:

2400

REV:

ARCHIT Type D

brickwork panel nded 440mm (w)

rwp For entrance canopy / porch see separate drawing by LGMH Architects Drawing Ref: LGMH0014-LGMH-GA-ZZ-DR-A-1058

STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985

CLIENT:

Legal & Ge

SITE:

Bonnington


REAR ELEVATION

Roof ridge 9.368

First Floor Ce

1350

Eaves 5850

Type A1

First Floor Lev

2025

First Floor 3133

Ground Floor

2175

Facing brick specification TBC

Ground Floor 0

Type B rwp

Flush level access to meet M4(3) requirements

REAR ELEVATION

P


Notes: xx

Party wall line

1350

300

eiling 5.998

vel 3.133

1800

Type A1

1350

Ceiling 2.843

REV:

DESCRIPTION:

BY:

DATE:

1050

Type A1

Patio Terrace Level

ASHP

ARCHITECTURE STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS

Web: www.sten-architecture.co.uk

Tel: 01924 950985

CLIENT:

Legal & General

SITE:

Bonnington Walk

Twitter: @STEN_arch Facebook: stenarchitectureltd Linkedin: Sten Architecture


SIDE ELEVATION

Roof ridge 9.368

35°

First Floo

Eaves 5850

First Floor 3133

First Floo

Ground F

Facing brick specification TBC windows * Optional for semi and end

terrace plots ( refer to site layout )

Ground Floor 0

9

SIDE ELEVATION


Notes: xx

or Ceiling 5.998

or Level 3.133

9553

*

1350

Floor Ceiling 2.843

REV:

DESCRIPTION:

BY:

DATE:

1050

Type A1

ARCHITECTURE Web: www.sten-architecture.co.uk

STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS

Twitter: @STEN_arch Facebook: stenarchitectureltd Linkedin: Sten Architecture

Tel: 01924 950985

CLIENT:

Legal & General

SITE:

Bonnington Walk Bristol

TITLE:

3B5PM4(3) Side Elevation

SCALE AT A3:

DATE:

DRAWN:

CHECKED:


GROUND FLOOR PLAN A

M4(2) COMPLIANCE KEY GROUND FLOOR -

Fire cavity barrier

1100

1585

6

Type B

328

SANITARY ACCOMMODATION ACCESS

970

Terrace consisting adjacent to externa

MAIN BATHROOM ACCESS ZONE, (REFER TO AD.M4(2) DIAGRAM 2.7A)

Dining 2843

450

10

KITCHEN

11 12 13 14 15 16

1048

729

Store 63

63

8

Hall

7

2843

1138

2100

MINIMUM 1200mm CLEAR SPACE IN FRONT OF AND BETWEEN ALL KITCHEN UNITS AND APPLIANCES.

9440

9

888

213

2

1

888

WC 2843

638

1538

3

rad.

rad.

888

cyl.

1273

850mm MIN CLEAR OPENING WIDTH TO FRONT DOOR

4

63

300mm WIDE x 1200mm LONG UNOBSTRUCTED SPACE TO LEADING EDGE OF ENTRANCE LEVEL DOORS

5 half height boxing stub stack

1200mm x 1200mm UNOBSTRUCTED ENTRANCE PLATFORM, WITH LEVEL ACCESS THRESHOLD, MINIMUM 900mm X 600mm COVERED ENTRANCE, ILLUMINATED

100

6

ENTRANCE LEVEL ACCESS

Store

LIVING ROOM WINDOW GLAZING TO BEGIN 850MM OR LOWER & WINDOWS EASY TO OPEN SWITCHES, SOCKETS, VENTILATION & SERVICE CONTROLS TO BE BETWEEN 450mm & 1200mm FROM FFL AND A MINIMUM OF 300mm FROM AN INSIDE CORNER. CONSUMER UNIT MOUNTED SO THAT SWITCHES ARE BETWEEN 1350 AND 1450 FROM FFL

347

DOORWAY & HALLWAY WIDTHS

850 min clear

327

THE MINIMUM CLEAR WIDTH OF EVERY HALL OR LANDING IS 900mm EVERY DOOR HAS A MINIMUM CLEAR OPENING WIDTH AS SET OUT IN TABLE 2.1

100

2155 rad.

100

FUTURE SHOWER 1000mm x 1000MM UNOBSTRUCTED ACTIVITY SPACE

Party wall

1100

736 100

350

3611

1000

1800

127

700

SANITARY FITTING UNOBSTRUCTED MANOEUVRING SPACE IN FRONT OF WC & WASH HAND BASIN

Fire cavity barrier

Type TBC 1468

1838 2188

For entrance canopy / porch see separate drawing by LGMH Architects Drawing Ref: LGMH 0014-LGMH-GA-ZZ-DR-A-1058

A

63

1023

6 1200mm x 1200mm unobstructed entrance platfor

GROUND FLOOR PLA


Notes: Gross Internal Floor Area 120.52 ROOM AREA (sq.m)

g of 150mm aggregate gravel strip al wall, then 3 x 450mm paving slabs 1500

Lounge 17.18 Kitchen / Dining 24.84 WC 2.56 Store (o/a) 2.86 Bedroom 1 12.34 Bedroom 2 12.43 Bedroom 3 9.83 Bedroom 4 9.83 Bathroom 4.57

1248 Type A1

1340

ASHP

328 rwp

WALL LEGEND.

328

2128 6942

1003

ASHP Hydrobox

DENOTES 150MM THICK LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD DRYLINING ON DABS WITH NOMINAL SKIM FINISH - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE BLOCKWORK - 12.5MM GYPROC WALLBOARD DRYLINING ON DABS WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT PLASTERBOARD ON DABS

3611

2843

2364

Kitchen

685

Type C1

2700

DENOTES 350MM THICK CAVITY WALL : - 102.5MM FACING BRICKWORK - 125MM WIDE CAVITY. 50MM AIRGAP THEN 75MM INSULATION - 100MM THICK 3.6N/MM² STANDARD AIRCRETE BLOCKWORK - 12.5MM PLASTERBOARD ON 10MM DABS WITH SKIM FINISH

DENOTES 93MM THICK NON LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - 63 X 38MM METAL STUDWORK AT 600MM CTRS. - 65MM ISOWOOL APR 1200 INSULATION - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT.

2700

3900 5052

1175

100

svp

DENOTES 93MM THICK NON LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - 63 X 38MM METAL STUDWORK AT 600MM CTRS. - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT.

888

DENOTES 370MM THICK PARTY WALL : - 25MM PLASTERBOARD ON DABS INTERNAL FINISH - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE CONCRETE BLOCKWORK - 100MM WIDE INSULATED CAVITY - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE CONCRETE BLOCKWORK - 25MM PLASTERBOARD ON DABS INTERNAL FINISH

3011

Living

FOR ALL MOVEMENT JOINT POSITIONS REFER TO STRUCTURAL ENGINEERS DRAWINGS 1248

Type A1

5074

ALL WALLS TO THE GROUND FLOOR WC AND PRINCIPLE BATHROOM (NOT EN SUITE) TO BE ABLE TO TAKE 1.5K/NM2. IF REQUIRED PATTRESS THE STUD WALLS ON THE WET ROOM SIDE FOR FIXING OF FUTURE FIXTURES SUCH AS GRAB RAILS.

2843

1453 327 100

1360

1698

CEILING HEIGHT

REV:

rad.

3475 Type D

2843

rwp

675

327

DESCRIPTION:

BY:

DATE:

ARCHITECTURE Web: www.sten-architecture.co.uk

STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS

Twitter: @STEN_arch Facebook: stenarchitectureltd Linkedin: Sten Architecture

Tel: 01924 950985

CLIENT:

Legal & General

SITE:

Bonnington Walk Bristol

TITLE:

4B6PM4(2) Ground Floor Plan

6943

rm

AN

SCALE AT A3:

1:50 PROJECT NO:

DATE:

20.10.2020 DRAWING NO:

DRAWN:

CHECKED:

SD REVISION:


M4(3) COMPLIANCE KEY FIRST FLOOR -

SANITARY ACCOMMODATION ACCESS SANITARY FITTING UNOBSTRUCTED MANOEUVRING SPACE IN FRONT OF WC & WASH HAND BASIN

MAIN BATHROOM TO BE 2600 x 2200 OR 2450 x 2450. (REFER TO AD.M4(3) DIAGRAM 3.15)

THE MINIMUM CLEAR WIDTH OF EVERY HALL OR LANDING IS 1050mm EVERY DOOR HAS A MINIMUM CLEAR OPENING WIDTH OF 850mm. CLEAR TURNING CIRCLE OF 1500mm DIAMETER WHEN THE DOOR IS CLOSED. LIVING ROOM WINDOW GLAZING TO BEGIN 850MM OR LOWER & WINDOWS EASY TO OPEN 740

Fire cavity barrier

A

1248 3510 Type A1

rad.

Bedroo

2991

2865

FUTURE SHOWER 1200mm x 1200MM UNOBSTRUCTED ACTIVITY SPACE 63

1987 11

BEDROOMS

12 13 14 15 16

8 7

loft hatch

6 5

4

3

2

137

Party wall 2295

8897

9

1

Land

Store / Future Lift provision with removeable floor

2235

1929 Towel

232

1113

1187

2865

1010

Bathroom 2865

svp

half height boxing 1050mm high

328

THE CEILING STRUCTURE TO EVERY BEDROOM IS TO BE STRONG ENOUGH TO ALLOW FOR THE FITTING OF AN OVERHEAD HOIST CAPABLE OF CARRYING A LOAD OF 200KG.

1010

10

63

MINIMUM 1000mm WIDE ACCESS FROM THE DOORWAY TO THE WINDOW. PRINCIPAL BEDROOM TO HAVE MINIMUM 1000mm WIDE ACCESS TO BOTH SIDES AND FOOT OF BED. OTHER DOUBLE BEDROOMS TO HAVE A MINIMUM 1000mm ACCESS TO ONE SIDE AND FOOT OF BED. SINGLE BEDROOMS TO HAVE MINIMUM 1000mm ACCESS TO ONE SIDE OF BED. EVERY BEDROOM TO HAVE 1200 x 1200 CLEAR MANOEUVRING SPACE

63

700

1100

DOORWAY & HALLWAY WIDTHS

327

FIRST FLOOR PLAN

Fire cavity barrier

3210 1772

Type A2 - obs 1248

A


Notes:

SWITCHES, SOCKETS, VENTILATION & SERVICE CONTROLS CENTRES TO BE BETWEEN 450mm & 1200mm FROM FFL AND A MINIMUM OF 300mm FROM AN INSIDE CORNER. CONSUMER UNIT MOUNTED SO THAT SWITCHES ARE BETWEEN 1350 AND 1450 FROM FFL

Gross Internal Floor Area 124.26 ROOM AREA (sq.m) Lounge / Kitchen / Dining 41.35 WC 3.51 Store (o/a) 3.20 Bedroom 1 15.62 Bedroom 2 14.32 Bedroom 3 10.26 Bathroom 6.83 Storage (o/a) 3.67

WALL LEGEND.

A 1248

63

1453

3497 Type A1

DENOTES 350MM THICK CAVITY WALL : - 102.5MM FACING BRICKWORK - 125MM WIDE CAVITY. 50MM AIRGAP THEN 75MM INSULATION - 100MM THICK 3.6N/MM² STANDARD AIRCRETE BLOCKWORK - 12.5MM PLASTERBOARD ON 10MM DABS WITH SKIM FINISH

328 rwp 328

2710

rad.

DENOTES 150MM THICK LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD DRYLINING ON DABS WITH NOMINAL SKIM FINISH - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE BLOCKWORK - 12.5MM GYPROC WALLBOARD DRYLINING ON DABS WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT PLASTERBOARD ON DABS

om 3

4432 63

DENOTES 93MM THICK NON LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - 63 X 38MM METAL STUDWORK AT 600MM CTRS. - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT.

2865

959

ALL WALLS TO THE GROUND FLOOR WC AND PRINCIPLE BATHROOM (NOT EN SUITE) TO BE ABLE TO TAKE 1.5K/NM2. IF REQUIRED PATTRESS THE STUD WALLS ON THE WET ROOM SIDE FOR FIXING OF FUTURE FIXTURES SUCH AS GRAB RAILS.

836

Store

26 1104

1200

FOR ALL MOVEMENT JOINT POSITIONS REFER TO STRUCTURAL ENGINEERS DRAWINGS

1285 208

2843

4403

1010

1010

DENOTES 370MM THICK PARTY WALL : - 25MM PLASTERBOARD ON DABS INTERNAL FINISH - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE CONCRETE BLOCKWORK - 100MM WIDE INSULATED CAVITY - 100MM THICK 3.6N/MM² LIGHTWEIGHT AGGREGATE CONCRETE BLOCKWORK - 25MM PLASTERBOARD ON DABS INTERNAL FINISH

9553

63

172 761

cyl. Store

ding

CEILING HEIGHT

REV:

DESCRIPTION:

BY:

DATE:

2530

270

Bedroom 2

ARCHITECTURE

rad.

2865

Web: www.sten-architecture.co.uk

STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS

Twitter: @STEN_arch Facebook: stenarchitectureltd Linkedin: Sten Architecture

Tel: 01924 950985

CLIENT:

Legal & General

SITE:

Bonnington Walk Bristol

TITLE:

3B5PM4(3) First Floor Plan

328

scured

A

Bedroom 1

270

513

90

h

DENOTES 93MM THICK NON LOAD BEARING PARTITION WALL : - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - 63 X 38MM METAL STUDWORK AT 600MM CTRS. - 65MM ISOWOOL APR 1200 INSULATION - 12.5MM GYPROC WALLBOARD WITH NOMINAL SKIM FINISH - NOTE: WET AREAS TO RECEIVE 12.5MM GYPROC MOISTURE RESISTANT.

3797 63 7070

1678

rwp 328

Type E

1248

1453

SCALE AT A3:

1:50

DATE:

20.10.2020

DRAWN:

SD

CHECKED:


steel beam within floor zone to carry floor joists

FIRST FLOOR JOIST PLAN

stairwell

1187

63

trimmer

Party wall

2295

1695

removeable floor to lift void infill 1695

2298

trimmer

bath svp

sink

toilet


Floor joists to be Mitek Posi-Joist PS10 253mm deep

Dashed lines indicate first floor studwork

cyl.


GROUND FLOOR SERVICES PLAN A Fire cavity barrier

Terrace consisting of 150mm adjacent to external wall, then

Type B

Party wall

Dining

rad. 10

2

11 12 13 14 15 16

Store

9

8

Hall

7

2

S

6

5

4

3

2

1

half height boxing stub stack

rad.

DES U rad.

WC

cmev

Store 2

SP EV

Fire cavity barrier For entrance canopy / porch see separate drawing by LGMH Architects Drawing Ref: LGMH 0014-LGMH-GA-ZZ-DR-A-1058

Type TBC

A

PIR

cyl.

1200mm x 1200mm unobstructed entrance platform

GROUND FLOOR PLAN


m aggregate gravel strip n 3 x 450mm paving slabs

ASHP

Type A1

Electrical Symbols Legend

rwp

mounted 700-1000 above f.f.l. mounted 700-1000 Twin switched socket outlet 13A above f.f.l. mounted 700-1000 Twin switched socket outlet 13A above f.f.l. with USB port mounted 700-1000 Twin switched socket outlet 13A above f.f.l. Fused switch to bar heater / cooker hood / stair lift / thro' floor lift / alarm & extract fans (N) = Neon indicator mounted between Consumer unit 1350-1450 above f.f.l. 13A socket in separately appliance space switched mounted 700-1000 Cooker & Hob 32A isolator above f.f.l. Twin switched socket outlet 13A

ASHP Hydrobox U

Type C1

U

CU

Kitchen

Thermostat

H Towel/Rad

Towel heater / Radiator Low energy pendant lamp Low energy LED ceiling recessed spotlight

PIR

2

svp S H

Energy efficient external PIR flood light (with integral photocell to front entrance) mounted 700-1000 Switch above f.f.l. mounted 700-1000 2 way Switch above f.f.l. Mains powered fully automatic smoke detector. To be linked to AOV window on top floor if in circulation space Heat detector Intercom

DES MP

cmev

Door Entry System Media plate (inc tv, 2x sat, 2xRJ45, 2xDbl skts) Vent Axia MVDC-MS A whole house extract system ceiling mounted

mounted 700-1000 above f.f.l.

U

Ceiling mounted extract fan linked to whole house extract SP

Solar Panel control panel

EV

EV control panel

Note dimensions shown are to u/s of electrical plate Type A1

S

MP

Living

rad.

Type D

rwp

A SUITABLE NUMBER (AT LEAST ONE ON EACH FLOOR) OF SELF CONTAINED SMOKE ALARMS MUST BE INSTALLED. THE ALARMS SHOULD BE INTERCONNECTED AND FIXED TO THE CEILING IN A CENTRAL POSITION BUT AT LEAST 300MM FROM ANY LIGHT FITTING. THE ALARM MUST BE FIXED STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS.


FIRST FLOOR SERVICES PLAN A Fire cavity barrier

Type A1

MP

rad.

Bedroom 3

11

12 13 14 15 16

10

S

9

7

loft hatch 5

4

3

2

cyl. Store

137

6 1

Landing

1113

Party wall

8

Store / Future Lift provision with removeable floor

2 Towel

svp

Fire cavity barrier

rad.

Bathroom

half height boxing 1050mm high

Type A2 - obscured

A

FIRST FLOOR PLAN


Type A1

P

rwp

Electrical Symbols Legend

rad.

mounted 450-1200 above f.f.l. mounted 450-1200 Twin switched socket outlet 13A above f.f.l. mounted 450-1200 Twin switched socket outlet 13A above f.f.l. with USB port mounted 450-1200 Twin switched socket outlet 13A above f.f.l. Fused switch to bar heater / cooker hood / stair lift / thro' floor lift / alarm & extract fans (N) = Neon indicator mounted between Consumer unit 1350-1450 above f.f.l. 13A socket in separately appliance space switched mounted 450-1200 Cooker & Hob 32A isolator above f.f.l. Twin switched socket outlet 13A

DES

U U

CU

Bedroom 1

Thermostat Towel/Rad

Towel heater / Radiator Low energy pendant lamp Low energy LED ceiling recessed spotlight

PIR

2

S H

Store

Energy efficient external PIR flood light (with integral photocell to front entrance) mounted 450-1200 Switch above f.f.l. mounted 450-1200 2 way Switch above f.f.l. Mains powered fully automatic smoke detector. To be linked to AOV window on top floor if in circulation space Heat detector Intercom

DES MP

cmev

Door Entry System Media plate (inc tv, 2x sat, 2xRJ45, 2xDbl skts) Vent Axia MVDC-MS A whole house extract system ceiling mounted

mounted 450-1200 above f.f.l.

Ceiling mounted extract fan linked to whole house extract SP

Solar Panel control panel

EV

EV control panel

Note dimensions shown are to u/s of electrical plate A SUITABLE NUMBER (AT LEAST ONE ON EACH FLOOR) OF SELF CONTAINED SMOKE ALARMS MUST BE INSTALLED. THE ALARMS SHOULD BE INTERCONNECTED AND FIXED TO THE CEILING IN A CENTRAL POSITION BUT AT LEAST 300MM FROM ANY LIGHT FITTING. THE ALARM MUST BE FIXED STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS.

Bedroom 2

Type E

rwp


FOUNDATION PLAN

2100

100

Party wall

3611

327

A

sleeper wall

100

1901

shower

2874

toilet

WC

stub stack

sink

328

Store

3368

A


N xx

internal water supply

foul drain discharge

327 rwp 328

6942

Periscopic Venti

stub stack

washing machine

dual sink floor socket

dish washer

Air brick within foundation wall

100

3611

Beam & block floor span indicated. Floor to be supplied by specialist subcontractor

svp

5074

Beam & block floor span indicated. Floor to be supplied by specialist subcontractor

327

REV:

3475 100

rwp

328

DESCRIPTION:

ARCHIT STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985

CLIENT:

Legal & Ge

SITE:

Bonnington


SECTION AA

Roof void

Type A2 - obscured

1350

300

35°

Indicative roof structure, to be designed by specia

2100

5850

Bathroom

Store / Future lift provision

Removable floor for future lift provision

2100

FRONT

Type TBC

Front door heads +02.100

WC

Store / Future lift provision

90mm Kingspan Kooltherm K103 DPM

70mm screed

0

DPC

Psi-block EPS Infill block 150mm BT02 Bison Jetfloor

Foundations and ground floor to Structural Engineer design and detail.

SECTION A-A traditional style


Notes xx

Ridge Height +09.414

trusses alist.

220

42°

Finished floor level at first floor +03.133

196

Bedroom 3

253

Landing

3133

Type A1

2902 Structural

2865 Clear

Ceiling level at first floor +05.998 Window head heights at first floor +05.550

Type A1

3133 Floor to Floor

2858 Structural

2843 Clear

Window heads at ground floor +02.400

REAR

REV:

Store

Kitchen

DPC

Finished floor level at ground floor +00.000

Telescopic ventilator

Min. 150mm ventilated void.

DPC

DESCRIPTION:

ARCHITE STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985

CLIENT:

Legal & Genera

SITE:

Bonnington Wa Bristol

TITLE:

3B5PM4(3) Section Throug

SCALE AT A3:

1:50 PROJECT NO:

DATE:

01.12.2020 DRAWING NO:


ROOF PLAN

3600

Roof truss span direction 35° pitch

Party Wall

726

Roof truss span direction 35° pitch

Fire rated Spandrel Panel

ROOF PLAN Closed fasc

1

ridge line

1

Closed fasc


N xx

Timber roof truss design by Specialist Sub-contractor

cia

Bedrooms c bedroom to allow for the overhead h carrying a lo

rwp

Dry verge

100 x 75 timber wallplate

8785

svp to tile vent on flexible duct through roof space

loft hatch 562

2850

REV:

ARCHIT STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS

100 x 75 timber wallplate

cia

DESCRIPTION:

rwp

Tel: 01924 950985

CLIENT:

Legal & Ge

SITE:

Bonnington Bristol

TITLE:

4B6PM4(2) Roof Plan


BATHROOM PLANS & ELEVATIONS

half height boxing stub stack

half height boxing stub stack

D

A C

B

A B C Ground Floor WC

850-1000 above FFL

D

Elevation A

Ground Floor WC

Elevation A

half height boxing

First Floor Bathroom

450

1200 above FFL

700 to easy use flush

1050

Towel

400-712 clear zone max 400 to top of pan 770-850 floor to rim

1050

B

450

Elevation A

770-850 floor to rim

Shaver point

First Floor Bathroom

Towel

B 1200 above FFL

C

Shaver point

400-712 clear zone

A

max 400 to top of pan

C

svp

700 to easy use flush

D D

Elevation B

svp

half height boxing

A

E

Elevation A Elevation


Elevation D

1050

700 to easy use flush 1050

max 400 to top of pan

700 to easy use flush

400-712 clear zone

Elevation C

max 400 to top of pan

400-712 clear zone

770-850 floor to rim

770-850 floor to rim

850-1000 above FFL

Elevation B

Elevation D

Elevation C

REV

REV:

DESCRIPTION:

Bath

Elevation Bath B B

Elevation C

A

Elevation D

Elevation C Elevation D

ST Th Ha W W

ARCHI

Te STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS CLIEN Tel: 01924 950985

Legal &

CLIENT:

SITE:

TITLE

SITE:

Bonning Bristol

TITLE:

4B6PM4 WC &PROJ B

SCAL

SCALE AT A3:

1:50 PROJECT NO:

Trad-LGMH

Tr DA

21

DR

H


GROUND FLOOR EXTERNAL WALL DETAIL

OV Wall Thickness 327.5

102.5mm facing brick

103

125

100

13

100mm (10.4kN first floo

13

Floor ins wall bloc Approve type a 12.5mm 8kg/m.s

75mm Kingspan K108 (50mm clear cavity as NHBC requirements) Airgap (50mm)

75mm K clear ca requirem

25mm p provide 0.8M2K

DPC min 150mm above ground Periscope underfloor ventilator Ensure Grade 2 water proofing is achieved where flush level access is required to perimeter of building

Floor ins wall bloc

Finished floor level at Ground Floor +00.000

EPS infill block PSI Block

Foundations TBC by engineer

GROUND FLOOR EXTERNAL WALL DETAIL


L

Celcon Aircrete Blockwork N to ground floor, 7.3kN to or)

sulation to tightly abut ckwork ed document e wall ties

m plasterboard ( nominal sq ) mounted on dabs

Kingspan K108 (50mm avity as NHBC ments)

perimeter insulation to minimum resistance of K/W

sulation to tightly abut ckwork FFL +00.000

Floor finish varies

70mm screed on slip sheet 90mm Kingspan Kooltherm K103 insulation DPM

BISON Jetfloor Oversite

Minimum 150mm air void

REV:

DESCRIPTION:

ARCHITE STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985

CLIENT:

Legal & Gene


EXTERNAL WALL FIRST FLOOR JUNCTION OV Wall Thickness 327.5 103

125

100

13

13

102.5mm facing brick 75mm Kingspan K108 (50mm clear cavity as NHBC requirements) Airgap (50mm)

253mm Mitek Posi-Joists, trimmers, restraints etc to manufacturers details Finnseal insulated closer or similar to manufacturers details

TYPICAL FIRST FLOOR JUNCTION DETAIL


N DETAIL 100mm Celcon Aircrete Blockwork (10.4kN to ground floor, 7.3kN to first floor) Floor insulation to tightly abut wall blockwork Approved document e wall ties type a 12.5mm plasterboard ( nominal 8kg/m.sq ) mounted on dabs

MDF skirting board

REV:

DESCRIPTION:

ARCH STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985

CLIENT:

Legal &


ROOF EAVES DETAIL

Concrete roof tile 'Sandtoft' TLE Dark / Light Grey subject to Planning Proprietary roof tile vent (flush fitting) into interlocking concrete roof tiles ( indicative position ) Proprietary cross flow ventilator to maintain min 25mm air gap Breathable membrane Timber battens 300mm layer of type 5u roofing underlay rolled into gutter. for profile tiles use proprietary eaves filler Timber tilt fillet

Fascia to be specified by client

12.5mm plaste

100 x 75 timbe 1538 from top underside of w

12.5mm plaste 8kg/m.sq ) mo

Approved Doc Type A wall tie 103

125 O/A Wall Thickness 327.5

100

13

13


er wallplate set at of beam & block to wallplate

35°

erboard ceiling

400mm of roll insulation laid between rafters and then laid at 90°

Timber truss design by Specialist Sub-Contractor

REV:

DESCRIPTION:

erboard ( nominal ounted on dabs

cument E es

ARCH STEN Architecture Ltd The Studio Harrison Street Wakefield WF1 1PS Tel: 01924 950985

CLIENT:

Legal

SITE:

Bonni Bristo

TITLE:

Tradit


ROOF RIDGE & WINDOW REVEAL DETAIL

Ridge tile Ridge tile batten Roof membrane cut short at top by 25mm to allow for air flow

Concrete roof tile 'Sandtoft' TLE - Dark / Light Grey subject to Planning Timber batten Proprietary roof tile vent (flush fitting) into interlocking concrete roof tiles

Breathable membrane Prefabricated truss

Timber roof truss desgin by specialist sub-contractor

RIDGE DETAIL

Flexible SVP connection to vented roof tile


OV Wall Thickness 327.5 103

125

100

13

100mm Celcon Aircrete Blockwork (10.4kN to ground floor, 7.3kN to first floor)

13

102.5mm facing Brickwork - subject to Planning

12.5mm plasterboard ( nominal 8kg/m.sq ) mounted on dabs

75mm Kingspan K108 (50mm clear cavity as NHBC requirements)

150mm cavity Dritherm 37 insulation

DPC cavity tray with stop ends to all window/door openings. All as NHBC 6.1.17

Lintel to Structural Engineers specification

Weepholes at 450mm ctrs 100mm reveal

HEAD 100

UPVC Grey RAL 7016 Casement window. Refer to STEN Architecture Window Schedule

Cill

CILL Insulated cavity closer

WINDOW REVEAL DETAIL


Contact Us Tel: 01924669424 info@sten-architecture.co.uk

© STEN Architecture Ltd 2016 Reg No. 08865776 England and Wales

Suite 4, Unit 1, Horbury, Wakefield Benton Office Park, Bennett Avenue WF4 5RA


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.