Cornerstone Outlook Action Uptown Proposal

Page 1

ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

CORNERSTONE UDBS/IOP for ACTION Housing

Jae Han Bae

Erica Tong

Steven Ko

Sandra Kalanyan

Yuriy Sountsov

OUTLOOK

ACTION UPTOWN PROPOSAL


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

CORNERSTONE OUTLOOK

Action Housing + Uptown Final: Comprehensive Implementation December 14th, 2012 Jae Han Bae, Erica Tong, Steven Ko, Sandra Kalanyan, Yuriy Sountsov

COVER SHEET

GC0.00


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

INDEX Index Governing Use Stipulations Sources

IN1.00 IN1.01 IN1.02 PROJECT NARRATIVE

Introduction / Decision Making Introduction / Decision Making Introduction / Decision Making

PN1.00 PN1.01 PN1.02 PROJECT SCOPE

Location Location Location Location Location Location Demographics Demographics Environmental Data Environmental Data Environmental Data Environmental Data Land Use and Zoning Requirements Land Use and Zoning Requirements Land Use and Zoning Requirements Land Use and Zoning Requirements Site Utilization Site Utilization Site Utilization Deviation Site Utilization Deviation Condition Condition Materials and Construction Materials and Construction Materials and Construction Materials and Construction Systems Systems Systems Systems Typology Case Study and Precedent Typology Case Study and Precedent

PS1.00 PS1.01 PS1.02 PS1.03 PS1.04 PS1.05 PS2.00 PS2.01 PS3.00 PS3.01 PS3.02 PS3.03 PS4.00 PS4.01 PS4.02 PS4.03 PS5.00 PS5.01 PS6.00 PS6.01 PS7.00 PS7.01 PS8.00 PS8.01 PS8.02 PS8.03 PS9.00 PS9.01 PS9.02 PS9.03 PS10.00 PS10.01 CODE ANALYSIS CA1.00 CA1.01

Land Use / Building / Adaptive Transformation Land Use / Building / Adaptive Transformation

SITE CONTEXT Water Management Construction Staging

SC1.00 SC1.01

IN1.00

ADAPTIVE TRANSFORMATION

Cover Sheet

GC0.00

Index: INDEX

Exterior Perspective Southeast Corner Exterior Perspective Southeast Corner Exterior Perspective Southwest Corner Exterior Perspective Southwest Corner Exterior Perspective Northeast Corner Exterior Perspective Northeast Corner Interior Perspective Northeast Corner Interior Perspective Northeast Corner Plan Information With Context Plan Information With Context Section Information With Context Section Information With Context Section Information With Context Section Information With Context

AT1.00 AT1.01 AT1.02 AT1.03 AT1.04 AT1.05 AT1.06 AT1.07 AT2.00 AT2.01 AT2.02 AT2.03 AT2.04 AT2.05 ASSEMBLY SEQUENCE

Phasing and Implementation Phasing and Implementation live/work Assembly and Associated Costs live/work Assembly and Associated Costs Retrofit Development and Associated Costs Retrofit Development and Associated Costs Retrofit Development and Associated Costs Retrofit Development and Associated Costs Retrofit Development and Associated Costs Retrofit Development and Associated Costs Interior Renovations and Associated Costs Interior Renovations and Associated Costs Garage Doors and Lawn Development and Associated Costs Garage Doors and Lawn Development and Associated Costs Garage Doors and Lawn Development and Associated Costs Storage Development and Associated Costs

AS1.00 AS1.01 AS2.00 AS2.01 AS3.00 AS3.01 AS3.02 AS3.03 AS3.04 AS3.05 AS4.00 AS4.01 AS5.00 AS5.01 AS5.02 AS6.00

SPECIFICATIONS Construction Details Construction Details

SP1.00 SP1.01 IMPLEMENTATION DOCUMENTATION

Critical Path Analysis Critical Path Analysis Lifetime Analysis Lifetime Analysis Business Model Business Model Revenue Analysis Revenue Analysis Hard Cost Analysis Soft Cost Analysis

IMP1.00 IMP1.01 IMP2.00 IMP2.01 IMP3.00 IMP3.01 IMP4.00 IMP4.01 IMP5.00 IMP5.01


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

GOVERNING USE STIPULATIONS These documents are the copyrighted property and intellectual property of Carnegie Mellon University and the authors of the documents. The documents shall not be reproduced or utilized for any purpose other than originally intended, without written consent of the authors. None of the documents included in the drawing index are intended to be considered in isolation of one another. All parties utilizing these documents for bidding, quantity survey, and/or construction shall consult the general notes and information located on each sheet before proceeding. All work shall conform to the requirements of the ICC International Building Code 2009 Edition, ICC International Residential Code 2009 Edition, governing AHJ Land Use and Zoning Ordinances/Codes, ADA 2000 Edition and all subsequent Amendments, and ANSI 117. Pittsburgh Fire Department regulations, Utility company requirements, and best trade practices.

Index: GOVERNING USE STIPULATIONS

IN1.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK SOURCE CITATIONS: PS1.01: 1. Fitzpatrick, Dan. “The Story of Urban Renewal.” Post-Gazette. N.p., 21 May 2000. Web. 2. Fullilove, Mindy T., MD. “Be It Ever So Humble.” Shelterforce Online. National Housing Institute, Nov.-Dec. 2004. Web. 3. http://www.city-data.com/city/Pittsburgh-Pennsylvania.html 4. http://apps.pittsburghpa.gov/dcp/PGHSNAP_v0.91_Beta_(Oct_2010)_For_Web.pdf PS3.00: 1. “Bluff.” Ninety Hoods. N.p., n.d. Web. 02 Nov. 2012. <http://ninetyhoods.wordpress.com/the-neighborhoods/bluff/> PS4.00: http://www.city.pittsburgh.pa.us/cp/maps/grid_maps.html http://library.municode.com/index.aspx?clientId=13525 PS4.02: Noun Project: Designed by Roman J. Sokolov, http://thenounproject.com/noun/people/#icon-No2300 Designed by Laurent Patain, http://thenounproject.com/noun/interchange/#icon-No2031 PS4.03: Sections in http://library.municode.com/index.aspx?clientId=13525&stateId=38&stateName=Pennsylvania Designed by Unknown Designer, http://thenounproject.com/noun/garbage-truck/#icon-No690 Designed by Giorgia Guarino, http://thenounproject.com/noun/listen/#icon-No7214 CA1.00: http://www.city.pittsburgh.pa.us/bbi/ International Building Code

IN1.02

Index: SOURCES


ACTION UPTOWN: CORNERSTONE OUTLOOK

Allegheny Council To Improve Our Neighborhoods secure and self-sufficient lives

Aim to provide a welcoming amenity to the residents of Uptown that they can continue to use on their own with minimal maintenance from a caretaker.

essential supportive services

Give back to the community, acting as a central backbone for social gatherings and events.

innovative technology

Utilize advanced technologies to augment and improve the lives of Uptown residents.

ARC48_550

ACTION HOUSING MISSION STATEMENT The mission of ACTION Housing is to empower people to build more secure and self-sufficient lives through the provision of decent, affordable housing, essential supportive services, asset building programs, and educational and employment opportunities. As an extension of that central mission, ACTION Housing links its activities with other public, non-profit and private entities in a common effort to address the needs of their clients. The organization provides decent, safe, and affordable housing for the most vulnerable populations despite their physical, developmental and income limitations; demonstrating leadership in the implementation of innovative technology in the delivery and management of social services. GOAL FOR UPTOWN Uptown Action Housing and the Issues of Practice class at Carnegie Mellon University concurrently focused on the Uptown neighborhood as a microcosmic sample of the transitional potential of a majority of Pittsburgh’s neighborhoods. In particular, this neighborhood poses interesting future urban outcomes due to its proximity to Downtown and other commercial neighborhood centers and the existing integrated ease of public transportation.

L

EL HIL

R SQUIR

DOWNTOW

N

DUQUESNE UNIVERSITY

OAKLAND

Figure 1.1: The extent of Action Housing’s collaboration with Carnegie Mellon University Issues of Practice. Marked are nearby neighborhoods and the neighboring university.

Project Narrative: INTRODUCTION / DECISION MAKING

PN1.00


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK WHAT IS CORNERSTONE OUTLOOK? While out of all the lots in Pittsburgh, 12% vacant and the lots in Uptown are 35% vacant, with 39 vacant lots in the blocks confined by Watson Street, Tustin Avenue, Jumonvillle Street, and Seneca Street, there are many opportunities in refurbishing existing and historic construction. Uptown is a transitioning community that retains vestiges of its former thriving state around the turn of the century. The vision of Action Uptown is focused upon the utilization of Uptown’s urban potential to remediate the lack of housing for below-market residents. Through these efforts, it also aims to sensitively reinforce a sense of community that is autonomous from the nearby Duquesne University and Downtown. Action Uptown proposes to provide repurposed housing with an environmental focus and other potential projects and has asked fourth year Carnegie Mellon architecture students to create proposals to meet these criteria. The chosen site for Cornerstone Outlook is the Corinthian Baptist Church at 2037 Forbes on the corner of Forbes Avenue and Seneca Street - a rarely used and neglected church with an empty side lawn that is yet relatively prominent in the surrounding neighborhood. The church is one of three churches in Uptown, with the other two churches at Duquesne University and at a spot five blocks towards the west. The property line of the church encompasses two lots (see fig. 1.2). The larger main lot includes the church building and the lawn. The other lot is used as housing for the pastor, but it is in disrepair. The location of the Corinthian Baptist Church and its attached lot on the centerline of Uptown and not too far from its center provides a great opportunity to transform something existing into something more.

A

C

B

SENECA ST.

WATSON ST.

FORBES AVE. Figure 1.2: Schematic of program layout.

c

a

flexible conditioned space

b

outdoor space

new primary axis (public access)

live-work

Community Center former primary axis (front entrance of church)

Figure 1.3: Schematic of program layout with axial transformation.

PN1.01

Project Narrative: INTRODUCTION / DECISION MAKING


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

REPURPOSING STRATEGIES REDEFINE the eastern fence INTRODUCE exterior community space OPEN east side to connect to interior space PRESERVE the other sides INJECT the live/work on the west side IDENTIFY live/work entrance and back

4 Figure 1.4: Original concept drawing of community interaction, northeast.

7

4

The solution is to repurpose the church as a community center. This resolution is based upon the recognized lack of need for a fully functioning church and the opportunity the building can provide if it was opened for a larger program. The program devoted to religious services would be reduced and the building would devote a greater amount of program to flexible community space. Multiple live/work participants would be contracted to maintain and organize events for the community center (including religious services) in exchange for free rooming.

5

Figure 1.5: Original concept drawing of community interaction, south.

5

Figure 1.6: Key map of drawings.

7 Figure 1.7: Original concept drawing of community interaction, north.

Project Narrative: INTRODUCTION / DECISION MAKING

PN1.02


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK UPTOWN’S PROXIMITIES Uptown is located strategically between Downtown’s central business district, Oakland, and Southside across the Monongahela River. However, as many highways and transportation routes pass through it, many people see Uptown only as a blur outside the window. It is not a place to get to, but a place to get through. This is why it is important for Uptown to rise in prominence and become another major Pittsburgh hub.

Figure 2.1: Map showing downtown Pittsburgh, Southside, Oakland, and Uptown between them all.

PS1.00

Project Scope: LOCATION


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

EXISTING COMMUNITY CENTERS The proposal would introduce another entry into a decently widespread set of buildings all around Pittsburgh. Relating to an eventual program for the proposal, there are three major types of community centers: social amenities, fitness clubs, and child care centers. Within a mile radius of the site are fourteen community centers, and a large bulk of the rest are in Downtown. Uptown itself, however, only has one: UPMC Mercy Hospital, which serves the larger community of Pittsburgh. The nearest of these centers to the proposal site is one of two Community Human Services Corporation sites. The CHS revitalizes Oakland and is in many ways similar to the proposal. The proposal is unique in that it combines several of these programs into an existing building in an area that is not dense with community centers. This way it can provide a far greater influence on its neighborhood without having to balance with other centers. Also, the typology of repurposed churches has been carried out in other neighborhoods of Pittsburgh, such as the Church Brew Works in Lawrenceville. Social Amenities: A - YMCA B - Community Leadership Development C - Community Care Behavior Health D - Point Park Community Classes E - The Gay and Lesbian Community Center of Pittsburgh F - Pittsburgh Community Reinvest G - UPMC Mercy Hospital H - Community Human Services Corporation I - Friendship Community Church J - Community Human Services Corporation K - Community Options - Pittsburgh L - Community Alternatives Inc M - Community Correctional Center Fitness Clubs: A - Verve Wellness B - Pilates Sol C - Executive Fitness Center D - One on One Personal Training and Fitness E - Gold’s Gym F - Grant Fitness Club G - Pittsburgh Personal Trainer H - Fitness With A Twist I - Bodyxchange J - East Carson Fitness Child Care Centers: A - Hug Me Tight Child Life Center B - Addison Terrace After School Program C - Oakland Sunshine Daycare Figure 2.2: Nearby social amenities, fitness clubs, and child care centers.

Project Scope: LOCATION

PS1.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK UPTOWN During the turn of the century, the area was called “the most beautiful place in Pittsburgh” due to its proximity to Downtown and waterfront property. However, the gentrification and revitalization efforts of the 1960’s shifted the demographics of the area. Now it is a dip between Downtown and Oakland in terms on economic stature, quality of life, and liveability. The area within a mile around the proposed site has fairly even green spaces. However, compared to Squirrel Hill, Shadyside, and Oakland, Uptown is sparsely forested. Most of the public and semi-public garden spaces are loosely maintained or serve as public littering spots.

Figure 2.3: Map of Uptown indicating the area of Action Uptown’s focus.

PS1.02

Project Scope: LOCATION


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

BUSWAYS AND PARKING ACCESS There are seven nearby bus stops within walking distance of the proposal. Forbes Avenue and Fifth Avenue run the major bus routes from Squirrel Hill, Shadyside, and Oakland areas to Downtown and South Side. There are also three large parking areas, two to the north and one to the south, only two blocks away. An unofficial parking area also exists to the northwest.

Figure 2.4: Map of Action Uptown’s focus indicating the locations of nearby access routes from parking lots and bus stops.

ACTION UPTOWN’S FOCUS The proposed site is within sight range of all of the other proposals for Action Uptown. Four of these are new construction, two are adaptive reuses of existing construction, two are revisions of side streets, and the last proposal deals with the unity of the blocks as a whole and thus affects the proposed community center. The proximity of the other proposals to the proposed community center means that a significant amount of change may be happening simultaneously, so the design of the community center would have to reflect that.

Figure 2.5: Map of Action Uptown’s focus indicating the locations and lots of the other projects.

Project Scope: LOCATION

PS1.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

Figure 2.6: The community center will both outreach and give back to the surrounding residential and commercial areas.

PS1.04

Project Scope: LOCATION


ACTION UPTOWN: CORNERSTONE OUTLOOK

PEOPLE AND VEHICLE ACTIVITY

L UA

D IVI

D

IN

Mechanical

1.1% of Pittsburgh residents use BIKES

SCALE OF ACTIVITY

The area receives a significant amount of varied foot traffic along the sidewalks and near the surrounding residences. As the site is along Forbes Avenue, buses often pass as well as heavy vehicle traffic during peak times of the day.

Non-mechanical

REVEREND, handles funerals too

Duquesne University RUNNERS frequent area

CHURCH-GOERS when Reverend comes in. 43.1% of Uptown residents WALK to their job

25.5% commute by CAR

23.1% use public BUSES

MO

NT

HL Y

WE

EK

LY

DA ILY

ESTIMATED RATE Figure 2.7: Chart mapping the scale and rate of site activity.

BI-

HO

The reverend currently employed at the church only visits every few weeks, even though the church is fully equipped for regular sessions. The rest of the foot traffic is comprised of walkers, bikers, and runners. This means that the site is frequented often, so the availability of an open area for stopping or lounging is an opportunity the community center is designed for. The bus stop near the site is also well situated to resonate with the community center. People leaving or getting on the bus may welcome the activity at a community center and may help propel it as a positive influence on the community.

L PA

ICI

N MU

ARC48_550

UR

LY

MAIL AND POWER CABLES The power cables crisscrossing the streets and connecting to the church building impact the site. Aside from being a visual sore, the wires may interfere with foliage on the lawn and the poles may impact visibility of the site from various directions along Forbes Avenue and Seneca Street.

mailbox

The mail route visiting the church and nearby housing as well as a mailbox across the intersection may have an impact and be impacted by any modification. Community activity, such as a mail delivery agent, is what the community center fosters and is a positive force in the revitalization of any community. The availability of a mail service depends on the safety of the community. If the community center can ensure that safety, then it plays a key, connected, role in the community.

Figure 2.8: Map showing power cables and mail routes.

Project Scope: LOCATION

PS1.05


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK DEMOGRAPHIC BREAKDOWN The vision for Uptown is to become a incubator for future economic and social developments in the city of Pittsburgh. Its proximity to the all ready flourishing neighborhoods of Downtown, Oakland, and Southside, grants Uptown a opportune position to attract various demographics. The current statistics of Uptown equals around 6,600 inhabitants. They represent only 2.16% of the total population of Pittsburgh. Only a small fraction of the 6,600 inhabitants represent the actual residents living in the Uptown neighborhood, as the greater portion are students who attend the nearby Duquesne University and prisoners at the Allegheny Police Department.

Figure 2.9: Visiting parties.

Figure 2.10: Population graphs.

PS2.00

Project Scope: DEMOGRAPHICS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

DEMOGRAPHIC BREAKDOWN

less high

than

Uptown’s neighborhood greatly lacks a educational background. The majority of the population only boasts high school education or less. The significant percentage of postgraduate degrees mostly likely reflects the students attending Duquesne University.

32.9%

ool h sch

hig

49.1%

uate l grad

o

scho

03.3%

e egre te’s d ia c o ass gree ’s de r lo e ee bach degr duate a r g t pos

04.1% 0.7%

1

Figure 2.11: Population breakdown by education.

Historically the white population of the area was replaced by the black community during the gentrification efforts of the 1960’s. Overall, the neighborhood lacks a diverse range of various ethnic groups.

% 31.17 % 65.83

black white

% % 0.58

01.11

asian other

0

Figure 2.12: Population breakdown by ethnicity.

ring factu manu tion porta trans rance / insu e c l n fina socia lth & a e h n al / atio ation inistr educ c adm li b u p ent ploym unem other ent rtainm e t n e ntific arts / / scie ional s s e f ation pro inform trade retail

Unemployment is a great issue for Uptown’s community. Although the area is concentrated with age groups well into the work force, almost half of the population is unemployed. This is reflected by the number of people under the poverty line, who consist of 58.6% of the total population. Most of the employed members work in the educational and health fields. The next largest group are involved in the arts and entertainment industry, which reflects the neighborhood’s transitional state with its under market value real estate.

05.2% 00.7% 05.9% 48.5% 00.4% 41.6% 02.1% 16.8% 05.0% 03.5% 11.8%

Figure 2.13: Population breakdown by employment.

0.08%

%

% 31.17

4

5 -59

e3 4 ag

age 5

%

00.52

4

0.00%

5 age <

%

03.50

%

24.74

-19

0 -3 age 2

0 -7 age 6

75

age >

The largest age groups are under the age of 40. Younger members represent this growing community, but the infantile percentage reflects that the intrinsic community growth has stagnated.

Figure 2.14: Population breakdown by age.

Project Scope: DEMOGRAPHICS

PS2.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

9 AM

SUN SHADING AND EXPOSURE

WINTER DECEMBER 21

FALL SEPTEMBER 21

SUMMER JUNE 21

A typical morning condition occurs around 9 AM in the spring, summer, and fall; a typical midday condition occurs around noon in the spring, summer, and fall and also until 3 PM in the summer; the lawn is typically partly shaded around 3 PM in the spring, fall, and winter; the lawn is fully shaded around 6 PM in the spring, summer, and fall; and the site is completely dark at 6 PM in the winter. The winter 9 AM condition is unique to the winter, as the sun is lower than it is during the other seasons.

SPRING MARCH 21

The large bulk of the church building and the adjacent lot structure pose problems in sun exposure in the morning and sun access during the late afternoon and evening for a large portion of the year.

12 NOON

Figure 2.15: Sun shading diagrams. The church building is marked as red. Each set of colored diagrams corresponds to the typical conditions described in the text on pages PS3.02 and PS3.03, with gray indicating unspecific conditions.

PS3.00

Project Scope: ENVIRONMENTAL DATA


ACTION UPTOWN: CORNERSTONE OUTLOOK

6 PM

OPPORTUNITY

FALL SEPTEMBER 21

SUMMER JUNE 21

SPRING MARCH 21

Forr all for seasons, the lawn located to the east of the church is exposed to plenty of sunlight from morning to mid-day. This allows this portion of the site to become an ideal location for public activities and congregations throughout the day.

WINTER DECEMBER 21

3 PM

ARC48_550

Project Scope: ENVIRONMENTAL DATA

PS3.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK TYPICAL MORNING/WINTER NOON In all seasons except winter, when this happens at noon, the low morning sun shines directly on the eastern facade of the church building, applying a strong amount of heat that will have to be dissipated through the rest of the day. Any glazing on this side would need temporary shading to reduce direct glare and heat exposure. Figure 2.16: Sectional view of solar effects on a typical morning or winter noon.

TYPICAL MIDDAY In all seasons except winter, the midday sun applies heat on the entire roof of the church building and the adjacent lot structure. At this angle the maximum amount of surface area is exposed, so the building receives the most heat and the lawn is unshaded. Insulation in the roofs would need to be used to reduce this source of heat. Figure 2.17: Sectional view of solar effects on a typical midday.

TYPICAL PARTLY SHADED LAWN In all seasons except summer, the afternoon sun partly shades the lawn by the church building. Because of this, any outdoor activities that require full daylight would need to end by around 3 PM during these seasons.

Figure 2.18: Sectional view of the extent of shading when the lawn is partly shaded.

TYPICAL FULLY SHADED LAWN In all seasons except winter, the early evening sun fully shades the lawn by the church building. Because of this, any outdoor activities should end by around 6 PM as the area will be without light. During the winter, the sun would have set so the entire site would be in darkness, necessitating an earlier closing time for the community center. Figure 2.19: Sectional view of the extent of shading when the lawn is fully shaded.

PS3.02

Project Scope: ENVIRONMENTAL DATA


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550 TEMPERATURE

The greatest impact yearly temperature has is on any public openings added to the community center. The yearly temperature also has an impact on what types and range of activities are possible in the lawn. PARTITION ACCESS Any openings in the church building can be open as long as the exterior temperatures do not fall below a comfort level somewhere around 65°. This means that, on average, they can be open from mid-March to mid-November during the day, however they might need to close on occasion as long as the low temperatures stay below freezing before May and after November. RANGE OF ACTIVITIES The freezing point can be a good swing point between cold and warm activity types. Warm activities may begin around May and last until early November. After that, the temperatures get lower until mid January when the average point reaches freezing, allowing cold activities to happen. There is a lull between mid-January and mid-February when the average temperature is at freezing and the community center lawn might be inactive.

80° 70° 60° High

50° 40° Average

30° 20°

Low

10° 0°

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

Figure 2.20: Yearly temperature ranges.

Project Scope: ENVIRONMENTAL DATA

PS3.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK WIND The site receives strong winds from the northwest, southwest, and southeast. The northwest winds would be blocked by the church building, but the combination of those winds with the southeast winds could allow for a channel of moving air diagonally through the church building. Any north- or west-facing windows in the live/work area would need to be operable to reduce drafts. The southwest winds would be blocked by the church building, however any south- or west-facing windows in the live/work area would need to be operable to prevent severe drafts. The southeast winds would impact the lawn and part of the church building. Planters with small trees could reduce these winds before they get to the lawn. Alternatively the winds could pass into the church building to allow for diagonal ventilation.

Figure 2.21: Yearly wind speed peaks from 13.5 mph to 25.5 mph. The more layers there are going out from the church the faster the wind is there, from that direction, on average yearly.

Figure 2.22: Dominant winds through the church building in plan.

INTERIOR VENTILATION Currently the church building can be well ventilated if the windows were made operable. Due to the size of the stained glass windows, prevailing winds entering the church would circulate from the main space around to the smaller rooms and side areas. Some wind might get in through the smaller windows, again if there were more operable than currently.

Figure 2.23: Air circulation patterns inside the church building. Each view shows the dominant flows most visible.

PS3.04

Project Scope: ENVIRONMENTAL DATA


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550 RAINFALL

Inches 1.25

The rainfall graph illustrates that the raining season peaks during the months of July and August at

1 .75 .5 .25 0

12 Midnight

6 Pm

12 Noon

6 Am

1/4“ Jan Feb Mar Figure 2.24: Yearly rainfall graph.

<0

8

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

CLOUD COVER

17 25 33 41 50 58 66 74+ % Covered

12 Midnight

Majority of winter and spring seasons are covered by cloud formations.

6 Pm

12 Noon

6 Am

Jan Feb Mar Apr May Figure 2.25: Yearly cloudcover frequency and density.

Jun

Jul

Aug

Sep

Oct

Nov

Dec

Project Scope: ENVIRONMENTAL DATA

PS3.05


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK LAND ZONING AND ALLOWED USES The following pages are based on the published Pittsburgh Code of Ordinances available at municode. com. The zone that Action Housing is focusing their attention is classified as R1A-H, meaning Single-Unit (R1) Attached (A) Residential High (H) Density. This, generally, allows the use of a zoning lot for one dwelling unit that is attached to one or more dwelling units by a party wall or separate abutting wall that is located on its own separate lot. This zone is in the neighborhood of Uptown, planning sector 15, and council district 6. There are four types of uses, permitted uses, uses with an administrator’s exception, special exception uses, and conditional uses. The permitted uses are: Single-Unit Detached Residential, Single-Unit Attached Residential, Agriculture (General), and Agriculture (Limited) with Beekeeping. The uses with an administrator’s exception are: Personal Care Residence (Small), Parks and Recreation (Limited), and Utility (Limited). The special exception uses are: Community Home, Child Care (Limited), Community Center (Limited), Cultural Service (Limited), Religious Assembly (Limited), and Religious Assembly (General). Finally, the conditional uses are: Communication Tower, Class C and School, Elementary or Secondary (General).

R1A-H - Single-Unit Attached Residential, High Density

GI - General Industrial

R2-VH - Double-Unit, Very High Density

EMI - Education Medical Institution

RM-M - Multi-Unit, Moderate Density

RP - Residential Planned

LNC - Local Neighborhood Commercial

SP-1 - Specially Planned

CP - Commercial Planned

SP-3 - Specially planned

H - Hillside

GT-A - Golden Triangle A

P - Park

GT-B - Golden Triangle B

UNC - Urban Neighborhood Commercial

GT-C - Golden Triangle C

NDI - Neighborhood Industrial

GT-E - Golden Triangle E

UI - Urban Industrial

Figure 2.26: Surrounding zoning and land use.

PS4.00

Project Scope: LAND USE AND ZONING REQUIREMENTS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

NEARBY AND PROPOSAL LOTS

34

36 167

165

168 169 170 171 172

240

161 161-A 162-A

163

88-0-1

82

164

160

82-A 85

247 246 245 244 243 241

158

159

156

157

96 95-1 95-2 94 95 93 88-0-2

253 252

257

251

98 97-0-1

99 100

255 261

271-4 271-5 271-1 0 271-9 265 267 271-3 265-A 263-1 271

266-B 266 266-C 266-A

147 14 7-A 148 148 -A 150 149 151 152 153 155 154

271-1 271-2 264 264-A 263-C 263-A 263 271-6 271-7 271-8

140 140-E-D

32

21

102 101

22 23 24 25 26 27 28 29 30 31

18

20

17

105 103 104

140 140--8 6 1140-7 40-B 139 14 141A 1 0-C 40-A 141 140 141 1 144-B 40-F 144-A 143-C 1 143-B 143-A 43 144 143 145 146

107 106 109

19

15

The proposed lots are 88-0-1 and 88-0-2, somewhat out of place numerically as the nearby lots are a few numbers above or below and without extra sets of numbers (see fig. 2.20). The 88-0-1 lot is fairly large and is one of the largest within Action Uptown’s focus. The 88-0-2 lot is comparable to any of the other residential lots.

257-A

Figure 2.27 Parcel map showing the proposal lots as well as all the surrounding lots within Action Housing’s focus..

Project Scope: LAND USE AND ZONING REQUIREMENTS

PS4.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK RESIDENTIAL COMPATIBILITY STANDARDS Since the site is in the R1A-H zone, it must conform to the site development standards for that zone. The proposal is allowed to have Contextual Side and Front Setbacks (CSS and CFS respectively) and Contextual Building Heights (CBH). However, as the two lots have adjacent occupied lots, the side setback is zero and the CSS standards do not apply.

or

The CFS can reduce the required minimum setback to a point established by adjacent construction or by over 50% of the adjacent lots on the same streetside. This has to be demonstrated to the Zoning Administrator with plans, surveys, maps and other evidence. The CFS does not increase the minimum setback nor does it reduce it so much that right-of-way widths are reduced below established minimums.

ZONING

and Figure 2.28: Contextual front setback regulations.

The CBH can be between the zone’s height limit and the average height of the adjacent lots on the same streetside. The CBH does not decrease the maximum allowed height or increase the minimum allowed height.

and

The code recommends any project pursues environmental considerations, but that is outside the scope of this proposal.

Figure 2.29: Contextual building height regulations.

Otherwise, the standards are: Minimum Lot Size: 1,800 sq. ft. Minimum Front Setback: 15 ft. Minimum Rear Setback: 15 ft.

40 ft.

15 ft.

Minimum Exterior Sideyard Setback: 15 ft. Minimum Interior Sideyard Setback: 5 ft. Maximum Height: 40 ft. (3 stories maximum)

15 ft.

5 ft. 1800 sq. ft.

15 ft. Figure 2.30: Lot standards.

PS4.02

Project Scope: LAND USE AND ZONING REQUIREMENTS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

RESIDENTIAL COMPATIBILITY STANDARDS Some additional restrictions apply to site development in R1A-H: 30 ft.

Dumpsters and refuse receptacles shall be located a minimum of 30 ft from any property in R1A-H.

Figure 2.31: Required minimum distance to a dumpster.

Z

Z

Operating Hours will be as follows: no trash or recycling will be collected between 10:00 p.m. and 6:00 a.m., no loading/unloading operations will be done between 10:00 p.m. and 6:00 a.m, and construction operations will occur only between the hours of 10:00 p.m. and 6:00 a.m.

Z

< 55 dB

Noise will not exceed 45 dB between the hours of 10:00 p.m. and 6:00 a.m. or 55 dB at all other times, as measured at the lot line.

< 45 dB

Figure 2.32: Operating hours and noise regulations.

Lights or combinations of lights that casts light on a public street shall not exceed 1 foot-candle (meter reading) as measured from the centerline of the street. Any light or combination of lights that cast light the adjacent lots shall not exceed 0.4 foot-candles (meter reading), as measured no more than 3 ft inside the lot line.

4 ft. candle midway

3 ft.

Odors that are detectable after the air has been diluted with six or more volumes of odor-free air shall not be permitted.

1 ft. candle

Figure 2.33: Lights limitations.

Signs: any sign shall not exceed 12 sq. ft. in face area; the use shall be limited to one sign for each primary entrance; and the sign may be attached to a wall of the building and shall not project more than 12 in. or may be situated as a pole sign not extending more than 12 ft. from the top of the sign to the grade beneath the sign and shall be setback at least 5 ft. from any lot line if that space is unoccupied.

Figure 2.34: Odors regulations.

<12 ft.

Cornerstone Outlook

<12 in.

<12 sq. ft. >3 ft.

Figure 2.35: Signs regulations.

Project Scope: LAND USE AND ZONING REQUIREMENTS

PS4.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK LOT DEVELOPMENT AND COMPLIANCE Of particular interest to this proposal is the potential of attaining a Special Exception in the R1A-H district for a Community Center (Limited). A Community Center (Limited) is a facility used for social or recreational programs generally open to the public and intended to accommodate and serve significant segments of the community which primarily serves the community in which it exists, and with a gross floor area of less than 5,000 square feet and for which fewer than 10 off-street parking spaces are provided. Activities at the community center would have to be noncommercial and nonprofit. During the process of acquiring the Special Exception, the approving body will determine if a community center can exist in the neighborhood based on its location, use, and activity. The proposal may also utilize the Religious Assembly (Limited) use. A Religious Assembly (Limited) is an establishment operated by a religious organization for religious worship, religious training and related religious services for which fewer than 20 parking spaces are required. During the process of acquiring the Special Exception, the approving body will work with the Planning Director to modify the standards and requirements to allow for the proposal to go through. Both uses will need to be handled carefully in regards to normal and event parking and traffic, as well as people and operational loads.

PS4.04

Project Scope: LAND USE AND ZONING REQUIREMENTS

<5000 sq. ft.

<10 Figure 2.36: Lot development required for a community center.

<20 Figure 2.37: Lot development required for a religious assembly.


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

EXEMPTION FROM COMPLIANCE

ZONING

45 days Figure 2.38: Process to get an exemption from compliance to the Community Center or Religious Assembly codes.

The proposal can only be either Community Center (Limited) or Religious Assembly (Limited). Both would require a Special Exception: give an application to the Zoning Administrator, attend a public hearing before the Zoning Board of Adjustments, and receive notice of the decision within 45 days. The Zoning Board of Adjustments will determine that the proposal will not be in any way detrimental to the surrounding neighborhood and propose alternative methods that the proposal may work without a Special Exception if there are discrepancies. The conversion of an existing church is further exempt from compliance with the Residential Compatibility Standards because it satisfies two of the following requirements for exemption: a) Development within the GT, DR, PD districts (see Fig. 2.19 for a map of nearby zones); b) Structural alteration of an existing building when such alteration does not increase the building’s square footage or height;

x

500 sq. ft.

<

<

c) A change in use that does not increase the number of off-street parking spaces required (minimum one for every 500 sq. ft, maximum one for every 200 sq. ft). 200 sq. ft.

x

Figure 2.39: Regulations on converting an existing church.

Project Scope: LAND USE AND ZONING REQUIREMENTS

PS4.05


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK Lot Number: 11-K-85 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

STOOP

DOOR MOULDINGS

RAILINGS

WINDOW MOULDINGS

CANOPY

DORMER

FENCING

GABLED ROOF

BASEMENT

FLAT ROOF

2,850 SF 36’ 0’ 30’ 11’ 0’

Figure 2.40: Diagram showing lot 11-K-85.

Lot Number: 11-K-82 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

STOOP

DOOR MOULDINGS

RAILINGS

WINDOW MOULDINGS

CANOPY

DORMER

FENCING

GABLED ROOF

BASEMENT

FLAT ROOF

587 SF 30’ 0’ 0’ 0’ 0’

Figure 2.41: Diagram showing lot 11-K-82.

Lot Number: 11-K-88-0-2 Lot Size: 2,035 SF Height: 38’ Front Setback: 0’ Rear Setback: 62’ Ext. Side-Yard Setback: 0’ Int. Side-Yard Setback: 0’

STOOP

DOOR MOULDINGS

RAILINGS

WINDOW MOULDINGS

CANOPY

DORMER

FENCING

GABLED ROOF

BASEMENT

FLAT ROOF Figure 2.42: Diagram showing lot 11-K-88-0-2.

PS5.00

Project Scope: SITE UTILIZATION


ACTION UPTOWN: CORNERSTONE OUTLOOK

Lot Number: 11-K-85 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

ARC48_550

1,965 SF 36’ 0’ 0’ 0’ 0’

DOOR MOULDINGS

STOOP

WINDOW MOULDINGS

RAILINGS

DORMER

CANOPY

GABLED ROOF

FENCING

FLAT ROOF

BASEMENT

Figure 2.43: Diagram showing lot 11-K-85.

Lot Number: 11-K-160 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

1,190 SF 36’ 0’ 8’ 2’ 0’

DOOR MOULDINGS

STOOP

WINDOW MOULDINGS

RAILINGS

DORMER

CANOPY

GABLED ROOF

FENCING

FLAT ROOF

BASEMENT

Figure 2.44: Diagram showing lot 11-K-160.

Lot Number: 11-K-159 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

2,030 SF 36’ 0’ 70’ 0’ 0’

DOOR MOULDINGS

STOOP

WINDOW MOULDINGS

RAILINGS

DORMER

CANOPY

GABLED ROOF

FENCING

FLAT ROOF

BASEMENT

Figure 2.45: Diagram showing lot 11-K-159.

Project Scope: SITE UTILIZATION

PS5.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK Lot Number: 11-K-169 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

STOOP

DOOR MOULDINGS

RAILINGS

WINDOW MOULDINGS

CANOPY

DORMER

FENCING

GABLED ROOF

BASEMENT

FLAT ROOF

760 SF 32’ 0’ 25’ 0’ 0’

Figure 2.46: Diagram showing lot 11-K-169.

Lot Number: 11-K-168 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

STOOP

DOOR MOULDINGS

RAILINGS

WINDOW MOULDINGS

CANOPY

DORMER

FENCING

GABLED ROOF

BASEMENT

FLAT ROOF

587 SF 34’ 0’ 0’ 8’ 0’

Figure 2.47: Diagram showing lot 11-K-168.

Lot Number: 11-K-175 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

STOOP

DOOR MOULDINGS

RAILINGS

WINDOW MOULDINGS

CANOPY

DORMER

FENCING

GABLED ROOF

BASEMENT

FLAT ROOF

1,050 SF 28’ 0’ 26’ 0’ 3’

Figure 2.48: Diagram showing lot 11-K-175.

PS5.02

Project Scope: SITE UTILIZATION


ACTION UPTOWN: CORNERSTONE OUTLOOK

Lot Number: 11-K-176 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

ARC48_550

1,050 SF 30’ 0’ 38’ 0’ 2

DOOR MOULDINGS

STOOP

WINDOW MOULDINGS

RAILINGS

DORMER

CANOPY

GABLED ROOF

FENCING

FLAT ROOF

BASEMENT

Figure 2.49: Diagram showing lot 11-K-176.

Lot Number: 11-K-177 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

Figure 2.50: Diagram showing lot 11-K-177.

1,050 SF 36’ 0’ 4’ 0’ 0’

DOOR MOULDINGS

STOOP

WINDOW MOULDINGS

RAILINGS

DORMER

CANOPY

GABLED ROOF

FENCING

FLAT ROOF

BASEMENT

Lot Number: 11-K-75 Lot Size: Height: Front Setback: Rear Setback: Ext. Side-Yard Setback: Int. Side-Yard Setback:

3,540 SF 32’ 0’ 17’ 0’ 0’

DOOR MOULDINGS

STOOP

WINDOW MOULDINGS

RAILINGS

DORMER

CANOPY

GABLED ROOF

FENCING

FLAT ROOF

BASEMENT

Figure 2.51: Diagram showing lot 11-K-75.

Project Scope: SITE UTILIZATION

PS5.04


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK SITE UTILIZATION DEVIATION The site deviates in two significant ways, but both are not ultimately issues.

Minimum Front Setback: 15 ft Actual Front Setback: 0 ft Although this does not comply with the current regulations of the Pittsburgh Code of Ordinances, it will not pose a problem because of the Contextual Front Setback exception, given in Section 925.06.B. It holds that as long as more than 50 percent of the buildings on a block have the same front setback, any proposed additions to this building would be able to follow this contextual standard regardless of the minimum front setback requirements for the district.

Figure 2.52: Diagram showing front setback deviation.

PS6.00

Project Scope: SITE UTILIZATION DEVIATION


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

Maximum Height: 40 ft (max. 3 stories) Actual Height with Apex: 43 ft (3 stories) Actual Height without Apex: 40 ft (3 stories) Although the height of the church exceeds 40 feet when the Ornamental Tower is included, it is acceptable by code because of the Exemptions from Height Standards given in Section 925.07.C of the Pittsburgh Code of Ordinances. The 7th item in this section exempts “Monuments and Ornamental Towers” from compliance with Height Standards for the zoning district.

Figure 2.53: Diagram showing height deviation.

Project Scope: SITE UTILIZATION DEVIATION

PS6.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK EXTERIOR CONDITIONS

8

1. Brickwork - in spots the brick facing is crumbling or in disrepair. With no original plaster surfacing the bricks have been exposed to the environment. These bricks would need to be restored.

10

3. Window Frames - the wooden frames around the windows have peeling paint and are in disrepair. A climatic seal and aesthetic quality would need to be preserved. They would all need to be repaired or replaced.

1

2

3

4

5

8. Window Debris - in the back yard the coverings over the windows are in severe disrepair. This would need to be addressed as part of the restoration of the back area.

10. Faux Brick - the attached lot is covered in a faux brick facing over the original brickwork. The purpose of this is unclear, as the original brick is not completely gone. This would have to be addressed as part of the back yard restoration.

6

7

8

9

10

PS7.00

Project Scope: CONDITION

3

5

1

5. Chimneys - two chimneys extend above the roof. These chimneys may be unstable and may need to be demolished to improve the look of the building.

9. Plaster - the western wall of the building is covered in an aging plaster that has visible cracks and is peeling away from the brickwork. It would need to be replaced or removed.

2

4

Figure 2.54: Key map.

4. Stained Glass Windows - of the twenty one windows around the building, eight are completely covered by a fiberglass covering, perhaps missing, three are partially covered, one is boarded over, two have steel bars, and the rest are dirty and unused exposed glass. All would need to be restored, replaced, or repaired.

7. Plant Growth - untended plants have encroached on the back of the building. These plants conceal parts of the building and may pose a hazard to the old brickwork. Along with the growth in the yards, these plants would need to be controlled.

6

9

2. Gaps in Sidewalk - in two spots at the front facade are holes in the sidewalk leading to basement glazing. The bricks around them are in disrepair pose a danger to foot traffic outside the building. These holes would need to be repaired.

6. Side Door - the side door in the back of the side yard is dilapidated. It should be part of the general restoration of the building.

7

Figure 2.55: Detail photos of exterior conditions keyed to overall photos.


ACTION UPTOWN: CORNERSTONE OUTLOOK

INTERIOR CONDITIONS

ORGANIZED

RARELY USED

ARC48_550

The quality of the interior conditions ranges from fully functional and well-kept to absolute clutter and disuse. The unkept rooms, particularly the closet spaces in the basement and the partitioned rooms on the second floor balcony, have been reduced to storage spaces without a sense of organization. Behind the clutter of piled up storage are signs of a sick building. The original stained glass windows have gaps thoughout the window frames or even have glass panels all together missing. Interior walls and ceilings suffer from heavy water damage. Molds are evident around the corners of rooms. Layers of wall plaster, ceiling boards, and floor tilings are found in deteriorated states throughout the entirety of the church.

OUT OF USE

CLUTTER

UNINHABITABLE

Figure 2.56: Detail photos of interior conditions ranging from organized to rarely used to out of use to clutter to uninhabitable.

Project Scope: CONDITION

PS7.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK FACADE DETERIORATION AND EXTERIOR MATERIAL MAPPING Significant portions of the south and east facades require restoration of the masonry exterior. Some areas would need to be replaced completely as the bricks there are gone or falling apart. The north and west facades have extensive foliage cover that would need to be removed and the masonry there checked for structural faults. Some areas of the masonry there would also need a facing restoration. The estimated area that would need to be completely replaced is 30.8 sq ft, so the estimated number of bricks would be about 220 bricks (mortar included). The estimated area that would need to be partially restored is 60 sq ft, so the estimated number of bricks within that area is about 430 bricks. Since the amount of degradation varies, some of these bricks might need to be completely replaced after inspection. The estimated area of foliage cover is 343 sq ft, however the bricks that may be structurally compromised may only comprise a small percentage of that area.

South

North

East

West Face restoration Complete replacement Foliage removal Figure 2.57: Elevations mapping areas and types of deterioration and restoration on church building.

3 5 1

4 6 2

Painted Wood Plaster Masonry Fascia Concrete Roof Tiles

Figure 2.58: Unfolded material mapping of exterior of church building with photo keys.

PS8.00

Project Scope: MATERIALS AND CONSTRUCTION


ACTION UPTOWN: CORNERSTONE OUTLOOK 1

2

3

4

5

6

ARC48_550

Figure 2.59: Detail photos of exterior materials.

Project Scope: MATERIALS AND CONSTRUCTION

PS8.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK EXTERIOR MATERIAL MAPPING

Wood Plaster Exposed Concrete Masonry

D

Wood and plaster

1

Carpet

2

C

Painted concrete Ceiling panels

D 3

Tiled

A

Wall connection

B

4

5

Floor connection D

6

FIRST FLOOR

C

7

A B 8 TOP FLOOR

9 TOP FLOOR

BALCONY

12

BASEMENT 10

KITCHEN 11

Figure 2.60: Unfolded material mapping of interior of church building with photo keys.

PS8.02

Project Scope: MATERIALS AND CONSTRUCTION


ACTION UPTOWN: CORNERSTONE OUTLOOK

1

2

3

4

5

6

7

8

9

10

11

12

ARC48_550

Figure 2.61: Detail photos of interior materials.

Project Scope: MATERIALS AND CONSTRUCTION

PS8.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK ACTIVE SYSTEMS The active systems in the church building include ducts and their associated machinery, faucets and toilets, windows and doors, and miscellaneous appliances. COMBINED ACTIVE SYSTEMS This graphic shows the active systems combined. All of the systems utilize user input to function, however many interface with passive systems as part of the whole building. Although the active systems appeared to be still functional, most of them were in need of retrofitting.

Figure 2.62: Diagram showing all active systems.

DUCTS The ducts extend from air handling units located in a mechanical room in the basement. The darker ducts are guessed at based on the locations of vents. Most of the vents are located in the floors with one potentially exiting out of the building.

Figure 2.63: Diagram showing ducts.

PS9.00

Project Scope: SYSTEMS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

FAUCETS AND TOILETS The majority of the faucets and toilets are in the basement. A faucet and toilet are located on the ground floor in two back rooms on the north end. The rest of the faucets and toilets are spread between the kitchen and two bathrooms in the basement.

Figure 2.64: Diagram showing faucets and toilets.

WINDOWS AND DOORS The first floor has a number of standard sized doors and also the large garage doors separating the main space from the extension area on the east side. The basement has some smaller doors leading to storage areas and a mechanical space. A vestibule connects the main entrance to two doors that lead to the santuary space. The santuary is divided by two folding doors that distingush the worshipping area from the waiting space. Similar folding doors are also installed on the second floor, separating the balcony from the storage rooms.

Figure 2.65: Diagram showing windows and doors.

MISCELLANEOUS APPLIANCES The ceilings of the santuary are equipped with fans and hanging lights. These applicances appear to be crucial elements to the space as they are integrated parts of the material pallete (mahogany wood) and a historic aesthetic. The basement has long rows of flourescent set in the ceiling. The kitchen in the basement is equipped with appliances such as a refrigerator, freezer, stove and oven.

Figure 2.66: Diagram showing miscellaneous appliances.

Project Scope: SYSTEMS

PS9.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK PASSIVE SYSTEMS The passive systems in the church building include fire safety, water pipes, pews as a unique furniture system, and electrical wiring. COMBINED PASSIVE SYSTEMS This graphic shows the passive systems combined. All of the systems remain active without user input, however many interface with passive systems as part of the whole building.

Figure 2.67: Diagram showing all passive systems.

FIRE SAFETY The only visible element of fire safety in the building is a fire extinguisher located in the extension space. It is unknown if there is fire insulation within any of the walls or roof. An alternative means of exit exists on the east facade of the church, although it appears to be inoperable.

Figure 2.68: Diagram showing fire safety equipment.

PS9.02

Project Scope: SYSTEMS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550 WATER PIPES

There are visible pipes in the mechanical room and the bathrooms in the basement and in the back rooms on the north end of the extension space. Their connections are unknown, however the pipes used for heating have to lead to the boiler and there also has to be a separate set of pipes for sewage.

Figure 2.69: Diagram showing water pipes.

PEWS The pews represent a unique passive system in the building because of their significant presence and importance to the church as a gathering place. The pews offer opportunities for recycling, as a furniture or resource for reusable material (wood). There is one pew that is half the length of the others.

Figure 2.70: Diagram showing pews.

ELECTRICAL WIRING The majority of the visible wires are on the first floor, with several prominently leading to the hanging lights and fans in the main space. There is a circuit breaker in the kitchen in the basement. It is unknown how the wires connect through the floors and walls.

Figure 2.71: Diagram showing electrical wiring.

Project Scope: SYSTEMS

PS9.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK lawn

live/work

High Line, New York / Deichmann Square, Be’ er Sheva Both of these projects utilized an active concrete intervention to spatially improve greenspace.

church

storage

1+2 Figure 2.72: Lawn design, bringing life to outdoor activity.

Chicken Point Cabin, Northern Idaho This cabin features a unique door that opens to a vista. The door is manually operated and syncs with the program of the resident.

3 Figure 2.73: Bringing the outdoors inside by opening up to the lawn.

Idea Home Design This fabricated wood shelving system fuses aesthetics with functionality with modern technology.

4 Figure 2.74: Interactive wall system .

Dominicanenkerk, Maastricht / Church Renovation House, Utrecht These retrofit projects introduced activities into existing church buildings and engaged their respective communities.

5+6 Figure 2.75: Renovation of Church interior to introduce diverse types of occupancy.

Live/Work Studio, Pittsburgh / Live Work Home, Syracuse These projects combined live and work into seamless experiences that mutually benefited the clients.

7+8 Figure 2.76: Live/Work, where live and work coexist.

illy coffee / muvbox , New York These projects take the idea of a habitable cargo container to the next level, pumping the containers full of use, or reuse, to achieve an effective actuating element.

PS10.00

Project Scope: TYPOLOGY CASE STUDY AND PRECEDENT

9 + 10 Figure 2.77: moveable storage unit.


ACTION UPTOWN: CORNERSTONE OUTLOOK

1

2

3

4

5

6

7

8

9

10 Project Scope: TYPOLOGY CASE STUDY AND PRECEDENT

ARC48_550

PS10.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK CODE ANALYSIS The code analysis is extracted from the 2009 Edition of the International Building Code. This page lists various specific definitions that are useful in understanding the original code text. The opposite page displays a reorganization scheme that groups similar code sections for facilitated reading and understanding as applied in the following pages. Useful Definitions: ACCESSIBLE: A site, building, facility or portion thereof that allows for wheelchair and disabled access. ADDITION: An extension or increase in floor area or height of a building or structure. ALLOWABLE STRESS DESIGN: A method of proportioning structural members, such computed stresses do not exceed specified allowable stresses. ALTERATION: Any construction or renovation to an existing structure other than repair or addition. APPROVED: Acceptable to the code official or authority having jurisdiction. BUILDING AREA: The area included within surrounding exterior walls. BUILDING OFFICIAL: The officer or other designated authority charged with the administration and enforcement of this code, or a duly authorized representative. In Pittsburgh, this is the Bureau of Building Inspection, which can be contacted at 412-255-2181. CONSTRUCTION DOCUMENTS: Written, graphic and pictorial documents prepared or assembled for describing the design, location and physical characteristics of the elements of a project necessary for obtaining a building permit. DWELLING UNIT: A single unit providing complete, independent living facilities for one or more persons in the form of habitable spaces. EXIT: A fire-protected passage out of a building. EXIT ACCESS: That portion of a means of egress system that leads from any occupied portion of a building or structure to an exit. EXIT PASSAGEWAY: An exit component that is separated from other interior spaces by fire-resistance-rated construction and opening protectives. FIRE AREA: The aggregate floor area enclosed and bounded by fire-resistance-rated walls. HABITABLE SPACE: A space for living, sleeping, eating or cooking that is not a bathroom, toilet room, closet, hall, storage or utility space. HANDRAIL: A horizontal or sloping rail intended for grasping by the hand for guidance or support. INTERNATIONAL RESIDENTIAL CODE: The code part of the ICC family of codes that deals specifically with residential construction. LOAD AND RESISTANCE FACTOR DESIGN: A method of proportioning structural members and their connections using load and resistance factors such that no limiting cases are achieved when the members are subjected to loads. MEANS OF EGRESS: A continuous and unobstructed path of vertical and horizontal egress travel from any occupied portion of a building or structure to a public way. NOSING: The leading edge of treads of stairs and of landings at the top of stairway flights. OCCUPANT LOAD: The number of persons for which the means of egress of a building or portion thereof is designed. PERMIT: An official document or certificate issued by the authority having jurisdiction which authorizes performance of a specified activity. PRIMARY FUNCTION: A primary function is a major activity for which the facility is intended. PUBLIC WAY: A street, alley or other parcel of land open to the outside air leading to a street. REGISTERED DESIGN PROFESSIONAL: An individual who is registered or licensed to practice their respective design profession (architecture) as defined by the statutory requirements of the professional registration laws of the state or jurisdiction in which the project is to be constructed. RELIGIOUS WORSHIP, PLACE OF: A building or portion thereof intended for the performance of religious services. REPAIR: The reconstruction or renewal of any part of an existing building for the purpose of its maintenance. STAIRWAY: One or more flights of stairs, either exterior or interior, with the necessary landings and platforms connecting them, to form a continuous and uninterrupted passage from one level to another. STORY: That portion of a building included between the upper surface of a floor and the upper surface of the floor or roof next above. TECHNICALLY INFEASIBLE: A fully code compliant and necessary-for-accessibility alteration of a building that has little likelihood of being accomplished because the existing structural conditions require the removal or alteration of an essential load-bearing member or because other existing physical or site constraints prohibit it.

CA1.00

Code Analysis: DEFINITIONS


ACTION UPTOWN: CORNERSTONE OUTLOOK 105 Permits 107 Submittal Documents 110 Inspections 111 Certificate of Occupancy 112 Service Utilities 303 Assembly Group A 310 Residential Group R 311 Storage Group S 419 Live/work Units 505 Mezzanines 508 Mixed Use and Occupancy 1004 Occupant Load 1009 Stairways 1010 Ramps 1011 Exit Signs 1012 Handrails 1021 Number of Exits and Continuity 1028 Assembly 1208 Interior Space Dimensions

Permits 105 Submittal Documents 107 Inspections 110 Certificate of Occupancy 111 Assembly Group A 303 Residential Group R 310 Live/work Units 419 Storage Group S 311 Change of Occupancy 3408 Mixed Use and Occupancy 508 Accessibility for Existing Buildings 3411 Compliance Alternatives (Existing) 3412 Repairs 3405 Alterations 3404 Additions 3403 Construction Safeguards 3302 Protection of Adjoining Property 3307

Demolition 3303 Site Work 3304 Excavation, Grading and Fill 1804 1604 General Design Requirements Formwork, Embedded Pipes and Construction Joints 1906 1804 Excavation, Grading and Fill Service Utilities 112 1906 Formwork, Embedded Pipes and Construction Joints 3302 Construction Safeguards 3303 Demolition 3304 Site Work 3307 Protection of Adjoining Property 3403 Additions 3404 Alterations 3405 Repairs 3407 Glass Replacement 3408 Change of Occupancy 3411 Accessibility for Existing Buildings 3412 Compliance Alternatives (Existing) HI09 Ground Signs

General Design Requirements 1604 Occupant Load 1004 Assembly 1028 Interior Space Dimensions 1208 Mezzanines 505

ARC48_550

REORGANIZATION DIAGRAM This reorganization diagram shows the revised order of sections that are analyzed in the following pages. On the left are all the sections in their original order in the IBC that are relevant to the proposal and on the right is the revised list broken down by type. The new “chapters” are as follows and are analyzed in sequence in the following pages: Application: CA2.00 - CA2.01 Building Land Use: CA3.01 - CA3.03 Construction: CA4.00 - CA4.01 Adaptive Transformation: CA5.00 - CA5.03 A comprehensive conclusion for the entire code analysis is at the end of this section on pages CA6.00 and CA 6.01.

Stairways 1009 Ramps 1010 Number of Exits and Continuity 1021 Glass Replacement 3407 Ground Signs HI09 Exit Signs 1011 Handrails 1012

Code Analysis: SEQUENCE OF SECTIONS

CA1.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK 105: PERMITS Section 105 deals with Permits. This section applies to all construction with some exceptions. Since the proposal is composed of substantial construction, a permit is required. Subsection 105.1 indicates that a project that is construction, alteration, repair, demolition, or that changes the occupancy of a structure, or that involves new electrical, gas, mechanical, or plumbing systems needs a permit. For the proposal, this is the case. Subsection 105.3 describes the process to get a permit: locate and describe the proposal, its use and occupancy, include construction documents, describe the value and sign this package and give it to the building official.

107: SUBMITTAL DOCUMENTS Section 107 deals with Submittal Documents. These are the documents required to be submitted for a permit. Subsection 107.1 describes the submission. As described in 105.3, the documents must include construction documents, any site data and other data.

CA2.00

Code Analysis: APPLICATION

105.1

Required. Any owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any such work to be done, shall first make application to the building official and obtain the required permit.

105.3

Application for permit. To obtain a permit, the applicant shall first file an application therefor in writing on a form furnished by the department of building safety for that purpose. Such application shall: 1. Identify and describe the work to be covered by the permit for which application is made. 2. Describe the land on which the proposed work is to be done by legal description, street address or similar description that will readily identify and definitely locate the proposed building or work. 3. Indicate the use and occupancy for which the proposed work is intended. 4. Be accompanied by construction documents and other information as required in Section 107. 5. State the valuation of the proposed work. 6. Be signed by the applicant, or the applicant's authorized agent. 7. Give such other data and information as required by the building official.

107.1

General. Submittal documents consisting of construction documents, statement of special inspections, geotechnical report and other data shall be submitted in two or more sets with each permit application. The construction documents shall be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed. Where special conditions exist, the building official is authorized to require additional construction documents to be prepared by a registered design professional.


ACTION UPTOWN: CORNERSTONE OUTLOOK

110.1

General. Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. It shall be the duty of the permit applicant to cause the work to remain accessible and exposed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection.

111.1

Use and occupancy. No building or structure shall be used or occupied, and no change in the existing occupancy classification of a building or structure or portion thereof shall be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction.

111.3

Temporary occupancy. The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid.

ARC48_550

110: INSPECTIONS Section 110 deals with Inspections. Inspections are required for any project that requires a permit. Construction cannot proceed until an inspector has verified the integrity of the completed parts. Subsection 110.1 indicates that the completed parts of construction need to remain accessible for an inspector and that any materials required for the inspection be handled without making the inspection agency liable.

111: CERTIFICATE OF OCCUPANCY Section 111 deals with the Certificate of Occupancy. This certificate allows the proposal to be occupied once it has been constructed and inspected. Subsection 111.1 indicates that both construction and a change of occupancy require certificates of occupancy to be issued by the building official. Subsection 111.3 allows for a certificate of occupancy to be issued temporarily for a part of the proposal to be occupied before the entire proposal is completed. The process of inspections and temporary certificates of occupancy can be useful for the proposal to arrange each part of the proposal to be subsequently open to the public once it is complete: the live/work space can be open for habitation, the community center can be open for events, and the lawn can be open for occupancy. Also, the future additions to the proposals will have to go through their own permit and inspection processes.

Code Analysis: APPLICATION

CA2.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK 303: ASSEMBLY GROUP A Section 303 deals with Assembly Group A. This is the group that the community center part of the proposal would fall into. Subsection 105.1 describes all of the types of construction that would be classified as assembly, including for the gathering for social or religious functions, or recreation. The subsection further lists specific descriptions, including community halls, gymnasiums, and places of religious worship. Since the community center part of the proposal includes these functions, the proposal falls into Assembly Group A-3.

310: RESIDENTIAL GROUP R Section 310 deals with Residential Group R. This is the group that the live/work part of the proposal would fall into. Subsection 310.1 describes all of the types of construction that would be classified as residential, namely anything that can be slept in as long as it is not regulated by the IRC or is not classified as Institutional Group I. Both of these special cases do not apply, the live/work part of the proposal is regulated by this code. The subsection further lists specific descriptions, including live/work units, indicating that the proposal falls into Residential Group R-2.

419: LIVE\WORK UNITS Section 419 deals with Live\Work Units. This is the group that the live/work part of the proposal would fall into. Subsection 419.1 describes what a live\work unit is along with limitations. The unit cannot be more than 3000 GASF, the office spaces must be on the first floor and not more than 50% of the space, and only five additional personnel are allowed to occupy the space along with the live/workers.

CA3.00

Code Analysis: BUILDING LAND USE

303.1

Assembly Group A. Assembly Group A occupancy includes, among others, the use of a building or structure, or a portion thereof, for the gathering of persons for purposes such as civic, social or religious functions; recreation, food or drink consumption or awaiting transportation. ... A-3: Assembly uses intended for worship, recreation or amusement and other assembly uses not classified elsewhere in Group A including, but not limited to: ... Community halls ... Gymnasiums (without spectator seating) ... Places of religious worship

310.1

Residential Group R. Residential Group R includes, among others, the use of a building or structure, or a portion thereof, for sleeping purposes when not classified as an Institutional Group I or when not regulated by the International Residential Code in accordance with Section 101.2. Residential occupancies shall include the following: ... R-2: Residential occupancies containing sleeping units or more than two dwelling units where the occupants are primarily permanent in nature, including: ... live/work units

419.1

General. A live/work unit is a dwelling unit or sleeping unit in which a significant portion of the space includes a nonresidential use that is operated by the tenant and shall comply with Sections 419.1 through 419.8. ... 419.1.1 Limitations. The following shall apply to all live/work areas: 1. The live/work unit is permitted to be a maximum of 3,000 square feet (279 m2); 2. The nonresidential area is permitted to be a maximum 50 percent of the area of each live/work unit; 3. The nonresidential area function shall be limited to the first or main floor only of the live/work unit; and 4. A maximum of five nonresidential workers or employees are allowed to occupy the nonresidential area at any one time.


ACTION UPTOWN: CORNERSTONE OUTLOOK

311.1

Storage Group S. Storage Group S occupancy includes, among others, the use of a building or structure, or a portion thereof, for storage that is not classified as a hazardous occupancy.

ARC48_550

311: STORAGE GROUP S Section 311 deals with Storage Group S. This is the group that the mobile storage future part of th proposal would most nearly fall into. Subsection 311.1 indicates that the storage would fall into this group as long as it is not classified as hazardous occupancy. According to Section 307, High-Hazard Group H, Exception 3, any closed system using flammable gases would not be classified as hazardous. This means that the outdoor grill equipment that would be part of the storage would not exclude the storage future part of the proposal from Storage Group S as it is not hazardous.

3408.1

Conformance. No change shall be made in the use or occupancy of any building that would place the building in a different division of the same group of occupancies or in a different group of occupancies, unless such building is made to comply with the requirements of this code for such division or group of occupancies. Subject to the approval of the building official, the use or occupancy of existing buildings shall be permitted to be changed and the building is allowed to be occupied for purposes in other groups without conforming to all the requirements of this code for those groups, provided the new or proposed use is less hazardous, based on life and fire risk, than the existing use.

508.1

General. Each portion of a building shall be individually classified in accordance with Section 302.1. Where a building contains more than one occupancy group, the building or portion thereof shall comply with the applicable provisions of Section 508.2,508.3 or 508.4, or a combination of these sections.

3408: CHANGE OF OCCUPANCY Section 3408 deals with a Change of Occupancy. This occurs in the entirety of the proposal because a former church becomes a community center, a former attached residence becomes a live/work space, and a former sideyard becomes a communal lawn. Subsection 3408.1 indicates that the changed occupancy must conform to the new codes for the new occupancy, which is the goal of these pages.

508: MIXED USE AND OCCUPANCY Section 508 deals with Mixed Use and Occupancy. The proposal falls under this section because it is a mixture of at least an Assembly, Residential, and Storage uses. Subsection 508.1 indicates that each use needs to conform to its applicable code requirements.

Code Analysis: BUILDING LAND USE

CA3.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK 3411: ACCESSIBILITY FOR EXISTING BUILDINGS Section 3411 deals with Accessibility for Existing Buildings. This section applies because the community center and live/work parts of the proposal are alterations of existing buildings. Subsection 3411.1 indicates that this section encompasses any construction that changes occupancy, adds to, or alters an existing building, which the community center and live/work parts of the proposal are. Subsection 3411.4 describes the regulations for a change of occupancy as it applies to existing buildings, indicating that certain accessible features must be part of the change: one or more accessible entrances and one or more accessible routes from said entrances to primary function areas. Subsection 3411.5 describes that any additions must follow the regulations for new construction. Subsection 3411.6 describes that any alterations must follow rules of accessibility outlined in Chapter 11 and ICC A117.1 unless technically infeasible. Subsection 3411.7 describes that any alterations affecting a primary function area, which is the case in the community center, must follow rules of accessibility. This compliance must also include accessible toilets or drinking fountains that serve the primary function area.

3412: COMPLIANCE ALTERNATIVES Section 3412 deals with Compliance Alternatives. These can be used with existing buildings without requiring the regular provisions. Subsection 3412.1 indicates that this section permits alteration and addition as long as the construction maintains or increases the quality of the existing building without requiring the regular provisions in preceding sections.

CA3.02

Code Analysis: BUILDING LAND USE

3411.1

Scope. The provisions of Sections 3411.1 through 3411.9 apply to maintenance, change of occupancy, additions and alterations to existing buildings, including those identified as historic buildings.

3411.4

Change of occupancy. Existing buildings that undergo a change of group or occupancy shall comply with this section.

... 3411.4.2 Complete change of occupancy. Where an entire building undergoes a change of occupancy, it shall comply with Section 3411.4.1 and shall have all of the following accessible features: 1. At least one accessible building entrance. 2. At least one accessible route from an accessible building entrance to primary function areas. 3. Signage complying with Section 1110. ...

3411.5

Additions. Provisions for new construction shall apply to additions. An addition that affects the accessibility to, or contains an area of, a primary function shall comply with the requirements in Section 3411.7.

3411.6

Alterations. A building, facility or element that is altered shall comply with the applicable provisions in Chapter 11 of this code and ICC A117.1, unless technically infeasible. Where compliance with this section is technically infeasible, the alteration shall provide access to the maximum extent technically feasible.

3411.7

Alterations affecting an area containing a primary function. Where an alteration affects the accessibility to, or contains an area of primary function, the route to the primary function area shall be accessible. The accessible route to the primary function area shall include toilet facilities or drinking fountains serving the area of primary function.

3412.1

Compliance. The provisions of this section are intended to maintain or increase the current degree of public safety, health and general welfare in existing buildings while permitting repair, alteration, addition and change of occupancy without requiring full compliance with Chapters 2 through 33, or Sections 3401.3, and 3403 through 3409, except where compliance with other provisions of this code is specifically required in this section.


ACTION UPTOWN: CORNERSTONE OUTLOOK

3405.1

General. Buildings and structures, and parts thereof, shall be repaired in compliance with Section 3401.2. Work on nondamaged components that is necessary for the required repair of damaged components shall be considered part of the repair and shall not be subject to the requirements for alterations in this chapter. Routine maintenance required by Section 3401.2, ordinary repairs exempt from permit in accordance with Section 105.2, and abatement of wear due to normal service conditions shall not be subject to the requirements for repairs in this section.

3404.1

General. Except as provided by Section 3401.4 or this section, alterations to any building or structure shall comply with the requirements of the code for new construction. Alterations shall be such that the existing building or structure is no less complying with the provisions of this code than the existing building or structure was prior to the alteration.

ARC48_550 3405: REPAIRS

Section 3405 deals with Repairs. This applies to the part of the proposal that involves the restoration of the exterior of the church building. Subsection 3405.1 indicates that repairs are to be made to levels described in Section 3401.2, namely levels of normal safeness, and that routine maintenance is also required to maintain those safety levels.

3404: ALTERATIONS Section 3404 deals with Alterations. This applies to the community center and live/work parts of the proposal. Subsection 3404.1 indicates that the alterations must not reduce the building’s code compliance and must comply with code for new construction.

3403.1

General. Additions to any building or structure shall comply with the requirements of this code for new construction. Alterations to the existing building or structure shall be made to ensure that the existing building or structure together with the addition are no less conforming with the provisions of this code than the existing building or structure was prior to the addition. An existing building together with its additions shall comply with the height and area provisions of Chapter 5.

3403: ADDITIONS Section 3403 deals with Additions. This applies to the community lawn and storage parts of the proposal. Subsection 3403.1 indicates that the additions must not reduce the building’s code compliance and must comply with code for new construction.

Code Analysis: BUILDING LAND USE

CA3.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK 3302: CONSTRUCTION SAFEGUARDS Section 3302 deals with Construction Safeguards. These are necessary precautions on a construction site. Subsection 3302.1 indicates that exits, fire protection, and sanitation are required to be maintained during construction of additions or alterations only if the building is occupied. Since the proposal’s construction will not be thus, these safeguards do not apply.

3307: PROTECTION OF ADJOINING PROPERTY Section 3307 deals with Protection of Adjoining Property. This is a regulation governing how nearby buildings are to be protected and warned of nearby construction. Subsection 3307.1 indicates that connecting walls and any roofs, foundations, footings, chimneys, and skylights must be protected during construction. Any water and erosion at the construction site must be controlled, as well as demolition. Also, notice of construction activities must be given to the nearby buildings no more than 10 days before construction begins.

3303: DEMOLITION Section 3303 deals with Demolition. Demolition is required in most of the proposal, largely in the live/ work and the lawn parts. Subsection 3303.1 indicates that the building official may require construction documents and a schedule of demolition.

3302.1

Remodeling and additions. Required exits, existing structural elements, fire protection devices and sanitary safeguards shall be maintained at all times during remodeling, alterations, repairs or additions to any building or structure. Exceptions: 1. When such required elements or devices are being remodeled, altered or repaired, adequate substitute provisions shall be made. 2. When the existing building is not occupied.

3307.1

Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work. Protection must be provided for footings, foundations, party walls, chimneys, skylights and roofs. Provisions shall be made to control water runoff and erosion during construction or demolition activities. The person making or causing an excavation to be made shall provide written notice to the owners of adjoining buildings advising them that the excavation is to be made and that the adjoining buildings should be protected. Said notification shall be delivered not less than 10 days prior to the scheduled starting date of the excavation.

3303.1

Construction documents. Construction documents and a schedule for demolition must be submitted when required by the building official. Where such information is required, no work shall be done until such construction documents or schedule, or both, are approved.

3303.2

Pedestrian protection. The work of demolishing any building shall not be commenced until pedestrian protection is in place as required by this chapter.

Subsection 3303.2 indicates that pedestrian protection must be in place before demolition can begin. As the proposal is adjacent to active sidewalks, this provision applies.

3304: SITE WORK Section 3304 deals with Site Work. This section applies mostly to the lawn part of the proposal, but may come into effect in the other parts too. Subsection 3304.1 indicates that any remaining chunks of wood or formwork be removed from the site before the building is occupied.

CA4.00

Code Analysis: CONSTRUCTION

3304.1

Excavation and fill. Excavation and fill for buildings and structures shall be constructed or protected so as not to endanger life or property. Stumps and roots shall be removed from the soil to a depth of at least 12 inches (305 mm) below the surface of the ground in the area to be occupied by the building. Wood forms which have been used in placing concrete, if within the ground or between foundation sills and the ground, shall be removed before a building is occupied or used for any purpose. Before completion, loose or casual wood shall be removed from direct contact with the ground under the building.


ACTION UPTOWN: CORNERSTONE OUTLOOK

1804.1

Excavation near foundations. Excavation for any purpose shall not remove lateral support from any foundation without first underpinning or protecting the foundation against settlement or lateral translation.

ARC48_550

1804: EXCAVATION, GRADING AND FILL Section 1804 deals with Excavation, Grading, and Fill. This applies because the live/work, lawn, and storage parts of the proposal include excavation work. Subsection 1804.1 indicates that any nearby foundations be supported before excavation commences. All three parts, the live/work, lawn, and storage, include excavation near the church building, so they would need to follow this provision.

1906.3

Conduits and pipes embedded in concrete. Conduits, pipes and sleeves of any material not harmful to concrete and within the limitations of ACI 318, Section 6.3, are permitted to be embedded in concrete with approval of the registered design professional.

1906: FORMWORK, EMBEDDED PIPES AND CONSTRUCTION JOINTS Section 1906 deals with Formwork, Embedded Pipes, and Construction Joints. The formwork regulations are standard, but since the lawn part of the proposal has an embedded sprinkler system, the part of the section dealing with embedded pipes applies. Subsection 1906.3 indicates that as long as the pipes are not harmful to the concrete they are in within the limitations in ACI, they can be embedded in the concrete.

112.2

Temporary connection. The building official shall have the authority to authorize the temporary connection of the building or system to the utility source of energy, fuel or power.

112: SERVICE UTILITIES Section 112 deals with Service Utilities. The community center, live/work space, and lawn parts of the proposal all use utilities, but may begin to use them at different times. Subsection 112.2 indicates that it is possible for utilities to be connected to a part of the building if allowed by the building official. This is important to allow for the function and occupancy of the parts of the proposal that are completed before the rest of the proposal is completed.

Code Analysis: CONSTRUCTION

CA4.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK 1604 : GENERAL DESIGN REQUIREMENTS Section 1604 deals with General Design Requirements. These are regulations defining structural and material design standards. This applies throughout the proposal.

1604.1

General. Building, structures and parts thereof shall be designed and constructed in accordance with strength design, load and resistance factor design, allowable stress design, empirical design or conventional construction methods, as permitted by the applicable material chapters.

Subsection 1604.1 indicates that any design should follow strength, load, stress and empirical design standards and methods. While the proposal does not go into specific load calculations, this section is important to keep in mind during design to allow for structural considerations.

1004 : OCCUPANT LOAD Section 1004 deals with the Occupant Load. This defines how many occupants the proposal may hold. From this calculation the number of required exits can be established, as analyzed in a later section.

1004.6

Mezzanine levels. The occupant load of a mezzanine level with egress onto a room or area below shall be added to that room or area’s occupant load, and the capacity of the exits shall be designed for the total occupant load thus established. TABLE 1004.1.1: MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT:

Subsection 1604.6 indicates that a mezzanine is to be counted as part of the space below it for purposes of calculating occupant load.

Unconcentrated Assembly(tables and chairs) Exercise Rooms

50 gross sq. ft.

Table 1004.1.1 lists some functions and their maximum assignable floor square footages for occupant load calculation that are relevant to the proposal. Assuming a square footage for the part of the community center that is not used for exercise of 4000 sq. ft., 1000 sq. ft. for the exercise rooms, and 3000 sq. ft. for the live/work space, the total occupant load comes out to be 302.

Residential

200 gross sq. ft.

1028 : ASSEMBLY Section 1028 deals with Assembly. This applies to the community center part of the proposal. Subsection 1028.2 indicates that any building with an occupant load greater than 300 must have a main exit. According to Table 1004.1.1 from Section 1004, the occupant load for the community center part of the proposal is less than that. Thus it does not have to have a designated main exit and may follow standard regulations on exit count.

CA5.00

Code Analysis: ADAPTIVE TRANSFORMATION

1028.2

15 net sq. ft.

Assembly main exit. Group A occupancies and assembly occupancies accessory to Group E occupancies that have an occupant load of greater than 300 shall be provided with a main exit. The main exit shall be of sufficient width to accommodate not less than one-half of the occupant load, but such width shall not be less than the total required width of all means of egress leading to the exit. Where the building is classified as a Group A occupancy, the main exit shall front on at least one street or an unoccupied space of not less than 10 feet (3048 mm) in width that adjoins a street or public way.


ACTION UPTOWN: CORNERSTONE OUTLOOK

1208.1

Minimum room widths. Habitable spaces, other than a kitchen, shall not be less than 7 feet (2134 mm) in any plan dimension. Kitchens shall have a clear passageway of not less than 3 feet (914 mm) between counter fronts and appliances or counter fronts and walls.

1208.2

Minimum ceiling heights. Occupiable spaces, habitable spaces and corridors shall have a ceiling height of not less than 7 feet 6 inches (2286 mm). Bathrooms, toilet rooms, kitchens, storage rooms and laundry rooms shall be permitted to have a ceiling height of not less than 7 feet (2134 mm). Exceptions: ... 2. If any room in a building has a sloped ceiling, the prescribed ceiling height for the room is required in one-half the area thereof. Any portion of the room measuring less than 5 feet (1524 mm) from the finished floor to the ceiling shall not be included in any computation of the minimum area thereof. 3. Mezzanines constructed in accordance with Section 505.1.

505.1

General. A mezzanine or mezzanines in compliance with Section 505 shall be considered a portion of the story in which it is contained. Such mezzanines shall not contribute to either the building area or number of stories as regulated by Section 503.1. The area of the mezzanine shall be included in determining the fire area defined in Section 902. The clear height above and below the mezzanine floor construction shall not be less than 7 feet (2134 mm).

1009.2

Headroom. Stairways shall have a minimum headroom clearance of 80 inches (2032 mm) measured vertically from a line connecting the edge of the nosings. Such headroom shall be continuous above the stairway to the point where the line intersects the landing below, one tread depth beyond the bottom riser. The minimum clearance shall be maintained the full width of the stairway and landing.

ARC48_550

1208: INTERIOR SPACE DIMENSIONS Section 1208 deals with Interior Space Dimensions. These regulations apply to the community center and live/work parts of the proposal. They regulate the redesigned partitions in the community center part and new partitions in the live/work part. Subsection 1208.1 indicates that habitable rooms must be more than 7 feet wide in any dimension and kitchens must have a passage of 3 feet or more between counters and walls or appliances. Both of these limitations apply to the proposal. Subsection 1208.2 indicates that habitable rooms and corridors must be 7 feet 6 inches or more in height, except for bathrooms, kitchens, storage rooms, and laundry rooms, which can be 7 feet in height. The second exception applies to the parts of the community center part of the proposal that have a sloped ceiling. In that case, only half of the area of that space is to be used to calculate the minimum height. The third exception is for mezzanines, which a part of the community center part of the proposal counts as, and specifies that Section 505.1 holds regulations concerning mezzanines.

505: MEZZANINES Section 505 deals with Mezzanines. This applies to the community center part of the proposal. Subsection 505.1 indicates that a mezzanine is to be considered part of the story that it is over and thus may not contribute to the building area, however it still counts towards the fire area. The height of the spaces below and part of the mezzanine has to be 7 feet or more.

1009: STAIRWAYS Section 1009 deals with Stairways. This applies to the community center and live/work parts of the proposal as both have new stairways. Subsection 1009.2 indicates that stairways must have a continuous headroom of 80 inches above any horizontal part of the stair. This is especially important for the community center part of the proposal’s stair as there is little room for it.

Code Analysis: ADAPTIVE TRANSFORMATION

CA5.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK 1010 : RAMPS Section 1010 deals with Ramps. This applies to the lawn part of the proposal as it incorporates an accessible ramp that leads to the community center. Subsection 1010.2 indicates that the ramp must not have a slope steeper than 1 to 12 if used for exit purposes or a slope not steeper than 1 to 8 if used for regular movement. Subsection 1010.6 indicates that the ramp must have landings at either end and at doors and that the length of each landing be at least 60 inches. Subsection 1010.7 indicates that the ramp be built out of regular building materials except that wood handrails are permitted. Since the ramp in the lawn part of the proposal is outdoors, it must be designed such that water cannot accumulate on its surfaces. Subsection 1010.8 indicates that a ramp with a rise of more than 6 inches must have handrails on both sides. Handrails are regulated in Section 1012.

1021 : NUMBER OF EXITS AND CONTINUITY Section 1021 deals with the Number of Exits and Continuity. This governs how many exits the proposal must have and may affect the design. Subsection 1021.1 indicates that all spaces in the proposal must have access to all of the exits and that the exits are to be determined by the occupant load. Based on Table 1021.1 and the previous calculation of an occupant load of 302, the proposal must have 2 exits.

3407: GLASS REPLACEMENT Section 3407 deals with Glass Replacement. This applies to the community center part of the proposal because of its existing dated glass assemblies. Subsection 1208.1 indicates that the replacement of glass is to be treated as installation of glass in new construction. Thus the condition of the existing panes does not matter.

CA5.02

Code Analysis: ADAPTIVE TRANSFORMATION

1010.2

Slope. Ramps used as part of a means of egress shall have a running slope not steeper than one unit vertical in 12 units horizontal (8-percent slope). The slope of other pedestrian ramps shall not be steeper than one unit vertical in eight units horizontal (12 .5-percent slope).

1010.6

Landings. Ramps shall have landings at the bottom and top of each ramp, points of turning, entrance, exits and at doors. Landings shall comply with Sections 1010.6.1 through 1010.6.5. ... 1010.6.3 Length. The landing length shall be 60 inches (1525 mm) minimum.

1010.7

Ramp construction. All ramps shall be built of materials consistent with the types permitted for the type of construction of the building, except that wood handrails shall be permitted for all types of construction... ... 1010.7.2 Outdoor conditions. Outdoor ramps and outdoor approaches to ramps shall be designed so that water will not accumulate on walking surfaces.

1010.8

Handrails. Ramps with a rise greater than 6 inches (152 mm) shall have handrails on both sides. Handrails shall comply with

Section 1012.

1021.1

Exits from stories. All spaces within each story shall have access to the minimum number of approved independent exits as specified in Table 1021.1 based on the occupant load of the story... TABLE 1021.1: MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD: 1-500 occupant load

2 exits

501-1000 occupant load

3 exits

More than 1000 occupant load

4 exits

3407.1

Conformance. The installation or replacement of glass shall be as required for new installations.


ACTION UPTOWN: CORNERSTONE OUTLOOK

H109.1

Height restrictions. The structural frame of ground signs shall not be erected of combustible materials to a height of more than 35 feet (10668 mm) above the ground. Ground signs constructed entirely of noncombustible material shall not be erected to a height of greater than 100 feet (30 480 mm) above the ground. Greater heights are permitted where approved and located so as not to create a hazard or danger to the public.

1011.1

Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. The path of egress travel to exits and within exits shall be marked by readily visible exit signs to clearly indicate the direction of egress travel in cases where the exit or the path of egress travel is not immediately visible to the occupants. Intervening means of egress doors within exits shall be marked by exit signs...

ARC48_550

H109: GROUND SIGNS Section H109 deals with Ground Signs. This applies to the lawn part of the proposal because of a proposed sign there that identifies Cornerstone Outlook. Subsection H109.1 indicates that signs made of combustible materials can be at most 35 feet tall and signs made of noncombustible materials can be at most 100 feet tall. Since the proposed sign is well under these limitations, this provision does not matter.

1011: EXIT SIGNS Section 1011 deals with Exit Signs. These regulations are important in the community center part of the proposal because it is proposed to have multiple exits. Subsection 1011.1 indicates that exit signs should mark exits and exit access doors and be readily visible. They should also be placed to mark a path of egress.

1012.1

Where required. Handrails for stairways and ramps shall be adequate in strength and attachment in accordance with Section 1607.7. Handrails required for stairways by Section 1009.12 shall comply with Sections 1012.2 through 1012.9. Handrails required for ramps by Section 1010.8 shall comply with Sections 1012.2 through 1012.8.

1012: HANDRAILS Section 1012 deals with Handrails. These are required on the accessible ramp that is part of the lawn part of the proposal.

1012.2

Subsection 1012.1 indicates that handrails be adequate in strength and attachment, which means they should withstand standard design loads.

1012.4

Subsection 1012.2 indicates that handrails are to be between 34 and 38 inches above the ramp surface.

Height. Handrail height, measured above stair tread nosings, or finish surface of ramp slope, shall be uniform, not less than 34 inches (864 mm) and not more than 38 inches (965 mm)... Continuity. Handrail-gripping surfaces shall be continuous, without interruption by newel posts or other obstructions.

Subsection 1012.4 indicates that handrails must also be continuous without breaks.

Code Analysis: ADAPTIVE TRANSFORMATION

CA5.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK CODE ANALYSIS CONCLUSION: APPLICATION By the International Building Code, the proposal must:

Acquire a permit by submitting construction documents, any site data and other data. Receive inspections. Be inspected before being rewarded a certificate of occupancy. Allow for a temporary occupancy for each subsequently completed part of the proposal. Have each part of the proposal be classified as separate occupancies and have each conform to their respective codes. Give notice of the construction to nearby buildings no more than 10 days before construction begins and protect those buildings’ connecting walls, roofs, foundations, footings, chimneys, and skylights. Provide where necessary construction documents and a schedule of demolition. Provide pedestrian protection during demolition. Have an occupant load of approximately 302. CODE ANALYSIS CONCLUSION: COMMUNITY CENTER By the International Building Code, the community center part of the proposal must:

Be classified as Assembly Group A-3. Allow for a change of occupancy and conform to the codes of the new occupancy. Have one or more accessible entrances and one or more accessible routes from said entrances to primary function areas. Follow the regulations for new construction for any additions, including structural considerations. Follow rules of accessibility for any alterations, also including toilets or drinking fountains and not reduce code compliance by means of those alterations, following it as if it was new construction. Consider compliance alternatives if the scheme improves the building. Perform restoration of the exterior to normal levels of safeness and set up routine maintenance. Allow for utilities to be connected for use before the entire proposal is complete. Count the mezzanine as part of the floor below and have the space below and above it have a height of at least 7 feet. Have habitable rooms of at least 7 feet in width, 7 feet 6 inches in height, except for ancillary spaces which can be 7 feet in height. Count only have of the area of a room with a sloped ceiling for height. Have 80 inches of headroom in stairways. Have a pathway to 2 separate exits. Replace glass as if it was being newly installed. Position exit signs over exits and exit access doors and other visible spots to mark a path of egress.

CA6.00

Code Analysis: CONCLUSION


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

CODE ANALYSIS CONCLUSION: LIVE/WORK SPACE By the International Building Code, the live/work part of the proposal must:

Be classified as Residential Group R-2. Allow for a change of occupancy and conform to the codes of the new occupancy. Follow the regulations for new construction for any additions, including structural considerations. Have one or more accessible entrances and one or more accessible routes from said entrances to primary function areas. Consider compliance alternatives if the scheme improves the building. Not reduce code compliance by means of alterations, following it as if it was new construction. Support nearby foundations during site work. Allow for utilities to be connected for use before the entire proposal is complete. Have habitable rooms of at least 7 feet in width, 7 feet 6 inches in height, except for ancillary spaces which can be 7 feet in height. Have 80 inches of headroom in stairways. Have a pathway to 2 separate exits. Position exit signs over exits and exit access doors and other visible spots to mark a path of egress. CODE ANALYSIS CONCLUSION: LAWN By the International Building Code, the lawn part of the proposal must:

Consider compliance alternatives if the scheme improves the building. Not reduce code compliance by means of additions, following it as if it was new construction. Follow the regulations for new construction for any additions, including structural considerations. Remove chunks of wood and other construction debris before occupancy. Support nearby foundations during site work. Ensure embedded pipes are not harmful to the concrete they are in. Allow for utilities to be connected for use before the entire proposal is complete. Have the accessible ramp be no steeper than 1 to 12, have landings at either end of at least 60 inches in length, be built out of regular building materials, have it drain water so that it does not accumulate, and have it include handrails on both sides if it rises more than 6 inches. Have the ramp handrails be able to withstand standard design loads, be between 34 and 38 inches in height, and be continuous. CODE ANALYSIS CONCLUSION: STORAGE By the International Building Code, the storage part of the proposal must:

Be classified as Storage Group S. Consider compliance alternatives if the scheme improves the building. Not reduce code compliance by means of additions, following it as if it was new construction. Support nearby foundations during site work. Code Analysis: CONCLUSION

CA6.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK WATER MANAGEMENT The introduction of a lawn in the proposal as well as roof modifications on the adjacent lot provide opportunities to reclaim or recycle stormwater. In the original configuration, the sloped roof of the church building allowed it to shed water to the sides. The building on the attached lot also has sloped roof conditions but many of them led to the water accumulating in inward-sloping corners. The lawn was also heavily sloped so the water there drained to the lowest point which was just off the southeast corner nearest the intersection. The biggest problems were that water would puddle in areas before it was able to get to a collection point and then to a sewer drain and that no water was reclaimed.

Figure 4.1: Water runoff scenarios on the original site.

SC1.00

Site Context: WATER MANAGEMENT


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

WATER RECLAMATION Once the proposal is in place, the simple roof of the old building is augmented by a system of guides on the roof of the adjacent lot as well as a perforated surface treatment that is part of the lawn. The guides can lead behind the building into a unified irrigation system that can keep the lawn watered without having to draw water from the city.

Figure 4.2: Water runoff scenarios on the proposal.

Site Context: WATER MANAGEMENT

SC1.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK PREPARING THE SITE FOR CONSTRUCTION The early stages of construction staging involve cleaning preparations that can be done with equipment that can remain on site for the rest of the construction phase.

Figure 4.3:Early construction.

As the site is cleared larger and more permanent (for the duration of construction) equipment is brought in.

Figure 4.4: Site preparation.

After the heavy equipment is brought in, the affected areas of the sidewalks are fenced off and the construction sites are marked off. As there are sidewalks on the opposite sides of Forbes Avenue

X

and Seneca Street this should not be a hazard for foot traffic passing through the area.

X X

X X

Figure 4.5: Site marking off.

SC2.00

Site Context: CONSTRUCTION STAGING


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

The live/work construction combined with interior work inside the church building extend and fully integrate construction activities across the whole site.

X

X

X X

X X

Figure 4.6: Construction begins inside out.

Other equipment is brought in and temporarily stored along the adjacent streets as needed for construction.

X

X

X X

X X

Figure 4.7: Temporary equipment is used as needed.

Site Context: CONSTRUCTION STAGING

SC2.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

AT1.00

Adaptive Transformation: EXTERIOR PERSPECTIVE SOUTHEAST CORNER


ACTION UPTOWN: CORNERSTONE OUTLOOK

Adaptive Transformation: EXTERIOR PERSPECTIVE SOUTHEAST CORNER

ARC48_550

AT1.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

AT1.02

Adaptive Transformation: EXTERIOR PERSPECTIVE SOUTHWEST CORNER


ACTION UPTOWN: CORNERSTONE OUTLOOK

Adaptive Transformation: EXTERIOR PERSPECTIVE SOUTHWEST CORNER

ARC48_550

AT1.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

AT1.04

Adaptive Transformation: EXTERIOR PERSPECTIVE NORTHEAST CORNER


ACTION UPTOWN: CORNERSTONE OUTLOOK

Adaptive Transformation: EXTERIOR PERSPECTIVE NORTHEAST CORNER

ARC48_550

AT1.05


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

AT1.06

Adaptive Transformation: EXTERIOR PERSPECTIVE NORTHWEST CORNER


ACTION UPTOWN: CORNERSTONE OUTLOOK

Adaptive Transformation: EXTERIOR PERSPECTIVE NORTHWEST CORNER

ARC48_550

AT1.07


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

AT1.08

Adaptive Transformation: EXTERIOR PERSPECTIVE LAWN


ACTION UPTOWN: CORNERSTONE OUTLOOK

Adaptive Transformation: EXTERIOR PERSPECTIVE LAWN

ARC48_550

AT1.09


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

AT1.10

Adaptive Transformation: INTERIOR PERSPECTIVE COMMUNITY CENTER USES, LOOKING SOUTH


ACTION UPTOWN: CORNERSTONE OUTLOOK

Adaptive Transformation: INTERIOR PERSPECTIVE COMMUNITY CENTER USES, LOOKING NORTH

ARC48_550

AT1.11


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

AT1.12

Adaptive Transformation: INTERIOR PERSPECTIVE LIVE/WORK


ACTION UPTOWN: CORNERSTONE OUTLOOK

Adaptive Transformation: INTERIOR PERSPECTIVE LIVE/WORK

ARC48_550

AT1.13


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

AT2.00

Adaptive Transformation: SECTION INFORMATION WITH CONTEXT


ACTION UPTOWN: CORNERSTONE OUTLOOK

Adaptive Transformation: SECTION INFORMATION WITH CONTEXT

ARC48_550

AT2.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK LIVE/WORK SECTION Section through the Live\Work area looking west. This section shows the stepped levels of occupancy ranging from the most public to the less public from left to right and the most private section, or the bedrooms, as sharing overlapping space with the Live\Work office. The Live\Work emphasizes an open floor plan to optimize transparency and the continous concept of living and working as a direct and integrated annex to the community center core.

Figure 5.1: Short section passing through the Live/Work space.

AT2.02

Adaptive Transformation: SECTION INFORMATION WITH CONTEXT


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

COMMUNITY CENTER SECTION Elevational section of the storage wall. This image depicts the nature of the materiality of the storage wall and the visual unification that the three occupiable spaces begin to have with its presence. As the wall begins to blur the divide between the community center and the Live\Work activity as shown in the adjacent section, the presence of the Live\Work philosophy of the community center is also emphasized.

Figure 5.2: Short section passing through community center.

Adaptive Transformation: SECTION INFORMATION WITH CONTEXT

AT2.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK LIVE/WORK PLANS Diagrammatic plans of the Live\Work spaces. From the roof plan, it appears that the core of the Live\Work Spaces are divided into a larger half and a smaller half. However, this is only true for the most private level, or the bedrooms and bathroom. The lower levels merge seamlessly with the smaller divide.

Angled Glass/Panel Roof

The use of walls along the longitudinal axis is minimized in favor of stepped spaces and soft partitions.

roof plan

roof plan

roof plan

Circulation is looped and begins in the office space. It carries parallel to the kitchen landing and merges Live/Work & Storage Corridor with the living room landing before the circulation path merges with the staircase leading to the private bedrooms and bathroom.

Live/Work & Storage Corridor

Live/Work & Storage Corridor Angled Glass/Panel Roof

Angled Glass/Panel Roof

Figure 5.3: live/work roof plan.

Balcony & Steps to Storage

Living Room

Balcony & Steps to Storage

level 2

level 2

Storage & Connecting Wall Kitchen_Dining

Storage & Connecting Wall

level 2

Living Room

Kitchen_Dining

Bedroom 1 Bedroom 2

Bedroom 1

Bathroom Bedroom 2 Bathroom

Living Room Figure 5.4: live/work second floor plan.

Living Room

ground level

Kitchen_Dining

Office & Live/Work entrance

DISH

Office & Live/Work entrance

Kitchen_Dining

DISH

Kitchen_Dining

ground level

Living Room

Office & Live/Work entrance

Figure 5.5: live/work diagrammatic floor plans

AT3.00

Adaptive Transformation: PLAN INFORMATION WITH CONTEXT


ARC48_550

10' - 6 1/8"

12' - 1 1/2"

12' - 4 1/2"

ACTION UPTOWN: CORNERSTONE OUTLOOK

STORAGE 85 SF

3' - 10"

4

FITNESS ROOM 650 SF 9' - 5 3/4"

10' - 6"

15 MECHANICAL ROOM 88 SF

17

EL. = +7'-6" A.F.F. CEILING HEIGHT TYP. 14

TYP. 3' - 2" 2' - 5"

2' - 5"

8' - 6 1/8"

UP

1' - 8" 10' - 4"

1' - 5" 1' - 6"

3' - 0"

3' - 6"

3

1

6' - 0 7/8"

3' - 5 1/8"

6' - 1 3/8"

TYP. 6

5 7

Keynotes 1. Standard 2’ x 4’ wood stud framing finished with drywall on both sides. 2. 3’ x 7’ exercise mats to be installed on 1” platform as moisture barrier. 3. Steel tube column to be covered on the exterior with drywall. 4. New CMU block wall to match existing. Finished with paint on both sides.

8

3' - 10 1/8"

W/ 1" NOSING

9 TYP.

(9) TREADS AT 11" WIDE

KITCHEN 178 SF 10

11

12

13

MEN'S RESTROOM 130 SF

7' - 1 3/8"

14' - 11 1/4"

6' - 7 3/4" WOMEN'S RESTROOM 130 SF

STORAGE 75 SF

3' - 0"

16' - 2"

TREAD WIDTH

8' - 0"

6' - 2 3/4"

1' - 6"

10' - 4"

2

12' - 5 3/4"

16

5. New vanity sink to be installed as specified on sheet SP2.02. 6. New toilet to be installed as specified on sheet SP2.02. 7. New bathroom stalls to be installed as specified on sheet SP2.02 8. New urinal to be installed as specified on sheet SP2.02. 9. New refrigerator

10. Dish washer to be installed beneath new countertop. 11. Sink to be installed in the countertop with sink hole. 12. Wooden countertop with sink hole. 13. Range stove top to be installed as specified. 14. Arrange exercise equipment as space will allow. 15. Demolish existing door and move to new location. 16. Keep water boiler. 17. New gas furnace as specified.

Adaptive Transformation: PLAN INFORMATION WITH CONTEXT

AT3.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK 17' - 11 5/8"

6' - 3 1/4"

(15) TREADS AT 11" WIDE W/ 1" NOSING

6' - 0 3/8"

2' - 6"

34' - 6 1/2"

6' - 0"

DOWN

3' - 0 1/8"

5' - 5"

8' - 1 1/8"

1 TYP. 13

3' - 1"

UNISEX 6

LIVING ROOM 270 SF EL. = +12' A.F.F. CEILING HEIGHT

4' - 10"

4' - 10 1/8"

14' - 8 1/4"

11' - 4 7/8"

2' - 0 1/8"

4' - 8 7/8"

2' - 3" 2' - 2 3/4"

2

5' - 6 3/4"

UP

2' - 6"

7' - 3 7/8"

CIRCULATION CORRIDOR 320 SF KITCHEN 410 SF

3

EL. = +8'-3" A.F.F. CEILING HEIGHT

LARGE ACTIVITY SPACE 942 SF

F

EL. = +22' A.F.F. CEILING HEIGHT 9' - 9 1/4"

20' - 0"

59' - 5 1/4"

(10) TREADS AT 11" WIDE W/ 1" NOSING

UP

7

UP 4

7' - 4 1/8"

5

3' - 0"

14' - 3"

8' - 0"

8' - 0"

8' - 4"

3' - 7 3/

2' - 4 1/8" 4' - 6"

11' - 8"

8' - 10" 4' - 0"

EL. = +10' A.F.F. CEILING HEIGHT

11 5' - 3"

6' - 0"

RECEPTION SPACE 420 SF 16' - 1"

20' - 0 1/8"

UP

2' - 1 3/8"

OPEN OFFICE 350 SF EL. = +11'-4" A.F.F. CEILING HEIGHT

8' - 0" TYP.

11" TREAD

7

9

10 8

8 7' - 9 1/2"

Keynotes 1. Double glazed window to be installed 3’ above floor level. 2. Mount railing onto the floor and the treads. 3. Range Oven install as instructed. 4. Counter top with sink hole.

AT3.01

TREAD

12

3' - 0"

UP 0' - 5 1/4"

TREAD

3' - 9 7/

Adaptive Transformation: PLAN INFORMATION WITH CONTEXT

5. Install dishwasher beneath counter top. 6. Re-finish existing church pew and secure to new location. 7. Custom fabricated bookshelves. Each cubbie to be 18” x 24”. Mount to the floor. 8. Remove existing single pane windows and replace with double pane as specified. 9. Double glazed window to be installed 18” above ground level.


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

14' - 7 1/4"

UNISEX RESTROOM 65 SF EL. = +8' A.F.F. CEILING HEIGHT

6' - 3 1/2"

2' - 0"

2' - 1"

ACE

11' - 9"

11' - 6 3/8"

2' - 6"

2' - 5 1/8"

6' - 0 1/2"

13

8' - 7"

MAINTANENCE ROOM 30 SF EL. = +8' A.F.F. CEILING HEIGHT

TYP.

FLEX. TRANSITION SPACE 300 SF EL. = +15' A.F.F. CEILING HEIGHT

(6) TREADS AT 11"

3' - 9 3/8"

TYP. 6

6' - 0"

6' - 0" 2' - 1 3/8"

T

2' - 6 1/4"

WIDE W/ 1" NOSING

5' - 11 1/2"

3' - 7 3/8"

CE

6' - 11 3/4"

5' - 3 3/8"

3' - 9 7/8"

6' - 5"

5' - 3"

UP

3' - 0"

TREAD WIDTH

8' - 4"

3' - 0"

' - 0"

TREAD WIDTH

3' - 9 7/8"

11' - 9"

11' - 6 3/8"

T

4' - 3"

2' - 4 1/8" 4' - 6"

4' - 9 7/8"

24' - 2 1/4"

3' - 11 7/8"

7' - 0"

8' - 2"

7' - 9"

7' - 4"

10. Cut glass panes as specified and fit to the exterior of existing window openings. 11. Match new finished floor to existing floor. 12. Curtain to be hung from railing attached to the underside of balcony. 13. Cut glass panes as specified and fit to the exterior of existing window openings

Adaptive Transformation: PLAN INFORMATION WITH CONTEXT

AT3.02


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

6

3' - 7 7/8"

11' - 9 3/8"

11' - 9 3/8"

13' - 2 3/8"

6' - 3"

19' - 4 5/8"

3' - 7 7/8"

DOWN

7' - 11 1/2"

7

BEDROOM 1 155 SF EL. = +10'-3" A.F.F. CEILING HEIGHT

TYP.

7

8

9

TYP.

TYP.

MEETING ROOM 380 SF EL. = +16'-6" A.F.F. CEILING HEIGHT

5' - 6 5/8"

W/ 1" NOSIN KITCHENETTE 260 SF

EL. = +7'-6" A.F.F CEILING HEIGH

18' - 3 3/4"

2' - 11 7/8"

4' - 3 1/8"

9' - 1"

11' - 4 5/8"

7' - 9 1/8"

BEDROOM 2 155 SF EL. = +10'-8" A.F.F. CEILING HEIGHT

1

1

2

3

3

2

Keynotes 1. Remove existing single pane windows and replace with double pane as specificed. 2. Cut 4’ x 8’ pane of glass to fit to the exterior of existing window openings. 3. Cut 2’ x 8’ pane of glass to fit to the exterior of existing window openings. 4. Install skylights as specified. Seal all edges with caulk and weatherstripping. 5. Standard 2’ x 4’ wood stud wall assembly finished with drywall on both sides. Align center to the centerline of columns. 6. Standard 2’ x 6’ wood stud wall assembly with 5” R-30 batt insulation.

AT3.03

4' - 10 1/2"

(11) TREADS AT 1

7

1

DOWN

3' - 0"

8' - 0"

5' - 8 5/8"

8' - 0"

6' - 0"

4' - 8 1/4"

8' - 0"

TREAD WIDTH

4

13' - 9"

7

13' - 2 3/8"

5' - 2 5/8"

Adaptive Transformation: PLAN INFORMATION WITH CONTEXT


5' - 8 5/8"

4' - 10 1/2"

5' - 0"

(11) TREADS AT 11" WIDE

5

10' - 11 5/8"

W/ 1" NOSING KITCHENETTE 260 SF EL. = +7'-6" A.F.F. CEILING HEIGHT 10

6' - 0"

6'-6" A.F.F. G HEIGHT

5' - 6 5/8"

7' - 9 1/8"

4' - 3 1/8"

G ROOM SF

ARC48_550

DOWN

3' - 0"

- 0"

TREAD WIDTH

ACTION UPTOWN: CORNERSTONE OUTLOOK

2

7. Standard 2’ x 4’ wood stuf wall assembly finished with drywall on both sides. 8. Glass panels held in place by aluminum framing. 9. Aluminum extrusion to support glass. 10. R-30 spray insulation applied to existing space between the ceiling and the roof.

Adaptive Transformation: PLAN INFORMATION WITH CONTEXT

AT3.04


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

2

1

1

1

2

1

3 8 8 4

8 9 7 8

38

3

7 8 9

7

5 10

6

11

12

16

13

33

31

32

35 14

30

15 29 18

28 27 26

17

19

24

23 20

21 22

AT4.00

Adaptive Transformation: GARAGE DOOR DETAILS

25


ACTION UPTOWN: CORNERSTONE OUTLOOK

16 13

14 33

35

32

15 19 34

20 18 21

29

37 28 26

24 25 30 36

22

27

23

ARC48_550

1. 1x6 lumber 2. 1x7 lumber 3. Standard brick 4. Single pane glass, 29x72, fit in 8 5. 1x5 lumber 6. Single pane glass, 13x72, fit in 10 7. 1x3 lumber 8. 1x4 lumber 9. Metal frame for glass inserts , 30x73 10. Metal frame for glass inserts, 14x73 11. 1x9 lumber 12. 1x4 lumber trim around double door 13. Metal structural frame for door 1 14. Metal hinge 15. Metal frame for door glass inserts, 24x27 16. Rubber seal on door edge 17. Door sill for double door 18. Metal structural frame for door 2 19. Metal frame for door glass inserts, 7x24 20. Metal frame for door glass inserts, 6x27 21. Metal frame for door glass inserts, 9x27 22. Metal frame for door glass inserts, 25x27 23. Single pane glass for door, 24x26 24. Single pane glass for door, 8x26, fit in 21 25. Metal door handle 26. Single pane glass for door, 5x26, fit in 20 27. Single pane glass for door, 1x23, fit in 30 28. Single pane glass for door, 24x26, fit in 19 29. Single pane glass for door, 24x26, fit in 15 30. Metal frame for door glass inserts, 2x24 31. 1x6 lumber trim framing double door 32. Single pane glass for door, 1x26, fit in 33 33. Metal frame for door glass inserts, 2x27 34. 1x4 lumber trim around double door 35. Metal structural frame for door 3 36. Door sill for single door 37. 1x6 lumber trim framing single door 38. Single pane glass, 24x72, fit in 9

Adaptive Transformation: GARAGE DOOR DETAILS

AT4.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK 10

2 1

3 1

7 5

6

16 14 11 2

15 3

1

1

9

4

5

8 6

8

7

9

14 10 1

1

AT4.02

Adaptive Transformation: GARAGE DOOR DETAILS

13 13


ACTION UPTOWN: CORNERSTONE OUTLOOK

1. 2. 3. 4. 5. 6. 7. 8.

20

ARC48_550

1x1 lumber trim Drywall cover Extruded metal frame Assembly of 5, 6, 7 Metal rod, spins in 7 Rubber gasket, 4� Metal sleeve, 1� Metal stopping blocks, prevent door from overspinning

20

9. 1x6 lumber 10. Rubber sill 11. Rubber strip maintaining contact with

19

drive mechanism 25 22

24 TYP.

12. Glass, 29x24 13. Metal L-shape 14. Metal structural member 15. Metal structural member with wheel structure

16. Metal structural member with side con-

23

nection 20 26 TYP.

21 TYP.

18 TYP. 28 TYP.

17 TYP.

12 TYP.

27 TYP.

20

17. 1x2 lumber, outer frame 1 18. 1x2 lumber, inner frame 1 19. Metal support frame 20. 1x1 lumber frame trim 21. 1x4 lumber, vertical frame 22. 1x4 lumber, outer frame 2 23. Metal frame for garage door glass inserts

24. 1x4 lumber, inner frame 2 25. 1x4 lumber, outer frame 3 26. 1x4 lumber, outer frame 4 27. Glass, 35x24 28. Glass, 17x24

Adaptive Transformation: GARAGE DOOR DETAILS

AT4.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK 1

2

3

4

5

6 7

8

9

10

11

12

27

14

13

28

14

26

15

16 7

23

10

22

19

18

15 30 17 18

25

AT4.04

Adaptive Transformation: GARAGE DOOR DETAILS

24

21

20

19


ACTION UPTOWN: CORNERSTONE OUTLOOK

31 4 1 2 6 3 29

29 29

29 9

7

8

18

19

21

20

15 17 16 13 17

30 18

28

15

29

29 29

19

20 21

ARC48_550

1. Metal brace, small 2. Metal wheel 3. Rubber gasket 4. Metal rod, spins in 5 5. Metal sleeve, 2.5” 6. Lumber support, upper 7. gear 8. chain 9. 1x1 lumber trim 10. Lumber lathed control handle 11. Metal attachment rod, slides in 12 12. Lumber window, front, 10, 11, 27, 26 slide sideways in this and in 28 13. Metal brace, large 14. Rifled gear 15. Wheel tensioning 16, transfers motion from control assembly (10, 11, 27, 26) to 7 16. Rubber belt 17. Metal rod, spins in 15, 7 18. Metal sleeve, 3” 19. Metal washer, 10” 20. Metal nut, 6” 21. Bolt cap, 4.5” 22. Metal rod, connects turn handle 23. Metal handle 24. Metal nut, 3” 25. Bolt cap, 2.25” 26. Metal rod, slides in 28 27. Transmission sleeve 28. Lumber window, back 29. Metal L-shape 30. Lumber support, lower 31. Metal structural member with wheel structure

29

7

Adaptive Transformation: GARAGE DOOR DETAILS

AT4.05


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

1

2

4

AT5.00

Adaptive Transformation: LAWN DETAILS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

LAWN SPRINKER SYSTEM MANAGEMENT This diagram shows the phasing and management of the lawn’s sprinkler system.

3

To keep the lawn management easy for the Live\Work people, the lawn is on a timed controller that also has a manual setting. The sprinkler heads are strategically located so that the lawn is uniformly watered. The concrete grid allows for the ease of fixing the pipes if necessary.

1

The lawn consists of several types of low maintenance grass. The grid allows for sections of the lawn to be removed and replaced with flowers or bushes more 3 easily than a free range/terrain landscape.

2

4

1

irrigation controller

2

shutoff valve

3

auto control valve

4

pop-up sprinkler head

Adaptive Transformation: LAWN DETAILS

AT5.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK VOLUMETRIC PENETRATION The initial phases of construction will begin with the lawn and pierce through both lots in a four step process. The first step is demolition and clearing of the lawn. The second step is demolition and shoring the eastern facade of the church building. The third step is clearing and preparation of the church building. The fourth step is demolition and clearing of the adjacent lot.

Figure 6.1: Diagram of existing site.

After these steps new construction can begin.

Figure 6.2: Diagram of the lawn that would be demolished and cleared.

Figure 6.3: Diagram of the eastern wall that will be demolished.

AS1.00

Assembly Sequence: PHASING AND IMPLEMENTATION


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

Figure 6.4: Diagram of the church building that would be cleared and prepared for access.

Figure 6.5: Diagram showing the existing adjacent lot that would be demolished and cleared.

Assembly Sequence: PHASING AND IMPLEMENTATION

AS1.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK NEW CONSTRUCTION EXTRACTION New construction will begin with the adjacent lot and work backwards out. Both retrofit and new construction will follow a five step process. The first step is new construction and reuse of the adjacent lot. The second step is new construction of the storage wall and partition between the two lots. At this point the Live/Work space can be inhabited and occupied. The third step is retrofit and new construction inside the church building. The fourth step is new construction of the garage doors and sealing of church building. At this point the community center can be inhabited and occupied.

Figure 6.6: Diagram showing new construction and refurbishing inside the adjacent lot.

The fifth step is new construction of the lawn and renovation of the church exterior. Once the community center is operational, another further step exists. Five years down the line, this is the installation of a mobile storage unit.

Figure 6.7: Diagram showing the storage wall that would be installed after the Live/Work space is constructed.

Figure 6.8: Diagram showing the interior retrofit that would be in the church.

AS1.02

Assembly Sequence: PHASING AND IMPLEMENTATION


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

Figure 6.9: Diagram showing the garage door.

Figure 6.10: Diagram showing the lawn and exterior renovation that would complete the proposal.

Figure 6.11: Diagrams of further development: a mobile storage unit and classroom modification.

Assembly Sequence: PHASING AND IMPLEMENTATION

AS1.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK LIVE/WORK DEVELOPMENT The live/work spaces will be developed within the shell of the existing building on the lot.

Figure 6.12: Base conditions for live/work development.

The first step will be to remove the windows and demolish the basement entrance in the wall between the church building and the adjacent lot. Then a part of the existing shell will be demolished, the connection space between the two buildings.

Figure 6.13: Demolition of existing construction.

The glass from the stained glass windows will be preserved for recycling as it is a unique relic of the old church.

Figure 6.14: Recycling.

AS2.00

Assembly Sequence: LIVE/WORK ASSEMBLY


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

The second step will be to remove the interior ledge and begin preparing the partition wall for reconstruction.

Figure 6.15: Church building interior partition preparation.

The third step will be to create openings and reinforce them temporarily. Once the reinforcements are in place, new steel members can be installed after which both the storage wall and interior live/work construction can proceed.

Figure 6.16: Partition reinforcement.

The final step will be to construct the connecting corridor that leads to the future storage unit. After this step construction continues as if for a new building.

Figure 6.17: Corridor and further construction.

Assembly Sequence: LIVE/WORK ASSEMBLY

AS2.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

The first step will be to prepare the floor plate and adjacent partitions.

Figure 6.18: The remaining facade, west partition, and floor plate.

The next step will be to secure studs and floor joists to begin shaping the topography of the interior first floor.

Figure 6.19: First floor joists and studs.

The next step will be to construct additional studs and structural elements.

Figure 6.20: Additional floor studs.

AS2.02

Assembly Sequence: LIVE/WORK ASSEMBLY


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

Once the first floor is complete, surface elements need to be secured onto the floor assembly.

Figure 6.21: Surfacing on the east axial passage.

Next, further floor elements are attached to the exposed joists.

Figure 6.22: Additional first floor elements.

The next step is to continue vertical construction and begin on the ceiling of the second floor.

Figure 6.23: More vertical studs.

Assembly Sequence: LIVE/WORK ASSEMBLY

AS2.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK Next, the second floor is constructed with further vertical elements.

After that, some roof elements and the remaining vertical elements are constructed.

Lastly, the roof is constructed.

Figure 6.23: Second floor joists.

Figure 6.24: Ceiling elements and more studs.

Figure 6.25: Roof elements.

AS2.04

Assembly Sequence: LIVE/WORK ASSEMBLY


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

At the final point any remaining surface features are constructed and furniture and appliances are installed.

Figure 6.26: Completed Live/Work.

Assembly Sequence: LIVE/WORK ASSEMBLY

AS2.05


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK INTERIOR RENOVATIONS The interior of the church building is first gutted to prepare for the Live/Work construction but begins its retrofit in earnest when the Live/Work is completed.

The first step in the renovations is to eliminate the existing walls, stairs, and balcony. Any structural weaknesses must be braced to prevent collapse as future construction is installed.

The next step is to patch and resurface the scarring left by the removal of existing partitions.

Figure 6.27: Existing partitions and plates in the church building.

Figure 6.28: Existing elements are removed.

Figure 6.29: Patches for the holes left over from replacement operations.

AS3.00

Assembly Sequence: INTERIOR RENOVATIONS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

The next step is to install the storage wall to the interior of the far wall.

Figure 6.30: The storage wall is constructed.

The last step is to construct new partitions, stairs, and windows.

Figure 6.31: Added construction.

Assembly Sequence: INTERIOR RENOVATIONS

AS3.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK EXTERIOR RENOVATION The exterior bricks are to be renovated and exterior surface features to be refurbished.

The first step is to secure scaffolding around the church and begin restoring the copper elements. The two chimneys will be removed.

The renovation continues downward, moving largely solely onto brick.

When the restoration reaches the bottom of the walls, it continues somewhat into the sidewalk to work on the openings there that lead to the basement.

Figure 6.32: Scaffolding is set up around all exterior brick surfaces, renovation begins with the copper elements.

Figure 6.33: the upper layers of the scaffolding are removed as renovations move down.

Figure 6.34: With the last few layers of brick needing restoration, the crumbling brick at the base is also repaired.

AS4.00

Assembly Sequence: EXTERIOR RESTORATION


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

GARAGE DOORS DEVELOPMENT The garage doors and lawn phase of construction will follow a nine step procedure. The first three steps will occur at the beginning of overall construction as the church building is prepared for retrofitting. The first step is to remove and set up temporary supports for the east facade.

Figure 6.35: East facade removal.

The second step is to remove and set up temporary supports for the east facade. At this point the double opening for the garage doors is left open so construction can move in and out to work on the Live\Work area and the retrofit and renovation of the church building.

Figure 6.36: East facade reinforcement.

The third step is to install the permanent supports that will later hold the garage doors. This happens once any large materials have been moved in or out of the building.

Figure 6.37: East facade construction, windows and doors.

Assembly Sequence: LAWN AND GARAGE DOORS

AS4.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK The fourth step happens after the Live\Work area and both the retrofit and renovation have been finished. The garage doors are installed and the renovation is completed excluding exterior restoration.

Figure 6.38: East facade construction, garage doors.

Next, the lawn is cleared of construction equipment and the soil is torn up and prepared.

The irrigation system is laid down.

Figure 6.39: Lawn preparation and soil development.

Figure 6.40: Lawn irrigation development.

AS4.02

Assembly Sequence: LAWN AND GARAGE DOORS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

Seventh, the concrete grid is laid over the pipes to establish a system for growth later on.

Figure 6.41: Lawn foundation development.

Figure 6.42: Lawn grass and planters development.

Next, the planters are set up. The lawn is not yet operational because the ramp has not been poured and other accessories are still to be installed.

Last, the recycling and trash bins are installed, a large designed sign post is installed, the ramp is poured and the handrails for it are installed.

Figure 6.43: Lawn ramps and miscellaneous development.

Assembly Sequence: LAWN AND GARAGE DOORS

AS4.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK CONTAINER The mobile storage transports event-related furniture and utensils between the storage space and the lawn. All four walls can potentially open out, activating new program through its extension of tools. When it is not in use by the community, one long wall can be flipped open to be used for private purposes by the Live\Work participant. Also, a shelving unit pivots out. When the mobile storage is stationed at the lawn, it can serve as a podium for the community space, a grill with a pivoting unit, and it can provide equipment such as tables and chairs.

Figure 6.44: Container deployed, large storage out.

The container sits on a bed with wheels for easy deployment and to provide a secure storage for the tools held within. The long doors can safely open and close via a hydraulic doors system.

Figure 6.45: Container deployed, grill out.

Figure 6.46: Container locked.

AS5.00

Assembly Sequence: FUTURE ADDITIONS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

Figure 6.47: Section through container, locked.

Figure 6.48: Section through container, deployed.

Assembly Sequence: FUTURE ADDITIONS

AS5.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

SP1.00

Specifications: LIVE/WORK SPECIFICATIONS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

LIVE/WORK SPECIFICATIONS SUMMARY Total Material and Labor Costs: 83,083 + 31, 778.40 = $114,861.40 Live/Work Cost Per Square Foot (1964 sq. feet): $58

Specifications: LIVE/WORK SPECIFICATIONS

SP1.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

LIVE/WORK RENOVATION CSI

Material

Price

Area/Quantity Material

072113100010 R-30 Batt Insulation

$1/sf

x

061110022000 2” x 4” Wood Studs

$5

x

220

061110022200 2” x 4” x 12 Wood Studs

$17

x

061110022200 2” x 4” x 8 Wood Studs

$3

0925001

Gyspum

0925001

Double Glazed Windows

$/hr

Labor

3

x

$60

= $180

= $1100

20

x

$60

= $1200

117

= $1904

20

x

$60

= $1200

x

304

= $912

20

x

$60

= $1200

$10

x

215

= $2150

60

x

$60

= $3600

$300

x

3

= $900

8

x

$60

= $4800

081416090010 Smooth Wood Door

$150

x

3

= $450

12

x

$40

= $480

073113100010 Asphalt Single Roofing

est.

1300 sq. ft

= $3000

with labor in estimate

096400000000 Wood Flooring

$ 10

x

= $19640

40

x

$60

= $2400

099103200300 Interior Paint

$35

x

31 gallons = $1085

60

x

$60

= $3600

099250001

$76

x

5 gallons

= $400

20

x

$20

= $400

40

= $400

20

x

$15

= $300

Kilz Primer

7740 sq. ft = $7740

Man Hrs

1964

096429108015 Transition Molding

$10/ 8 ft x

113113433300 Garbage Disposal

$160

x

1

= $160

0.25 x

$20

= $5

224116303300 Stainless Steel 43” Kitchen Sink

$ 300

x

1

= $300

3

x

$20

= $60

224139101300 Kitchen Faucet with Pull Out Spray

$70

x

1

= $70

0.8

x

$20

= $16

13113239797

$500

x

1

= $500

4

x

$40

= $160

113113130750 Range, Freestanding w/oven 1.6

$500

x

1

= $500

2

x

$40

= $80

113113534150 Range Hood

$140

x

1

= $140

2

x

$40

= $80

113113131250 Microwave Oven

$200

x

1

= $200

2

x

$20

= $40

220505101301 Lavatory Sink

$120

x

1

= $120

1

x

$40

= $40

224139102120 Lavatory Faucet with Pop up Drain

$35

x

1

= $35

1.2

x

$40

= $48

224139104220 Faucet/fitting for Shower Head

$50

x

1

= $50

0.5

x

$20

= $10

224119100010 Residential Bathtub

$400

x

1

= $400

4

x

$60

= $240

224139104220 Towel Bar

$20

x

1

= $20

0.25 x

$20

= $8

102813130200 Shower Curtain Rod

$20

x

1

= $20

0.25 x

$20

= $8

1554002

$200

x

1

= $200

4

$25

= $100

Refrigerator

Toilet, Low Flow

SP1.02

Specifications: LIVE/WORK SPECIFICATIONS

x


ACTION UPTOWN: CORNERSTONE OUTLOOK

CSI 0990002

Material Caulking

Price

Area/Quantity Material

$25

per case

Man Hrs

ARC48_550

$/hr

Labor

= $25

1

x

$60

= $60

122113000000 Window Blinds

$50 per window x 4

= $200

0.42 x

$20

= $8.40

123223100700 Custom Cabinets

$3000

= $3000

25

x

$60

= $1500

123600000000 Countertops

$1500

8.25 x

$60

= $495

113133237260 50 Gallon Water Heater

$1200 x

1

= $1200

6.4

x

$20

= $128

230505100100 Air Conditioner, 3 ton

$5000 x

1

= $5000

8

x

$25

= $200

233300000000 Air Duct Cover

$7

x

6

= $42

2.4

x

$20

= $48

260590106200 Light Fixtures

$50

x

40

= $2000

20

x

$25

= $500

220505000000 Plumbing Piping

$14,000

estimated

= $1400

calculated in estimate

260500000000 Electricity Installation

$5,000

estimated

= $5,000

calculated in estimate

042119190010 Brick Veneer Masonry Exterior

$20

x

= $14,180

20

x

$22

= $440

07419920011 Aluminum Panels

$10

x

400

= $400

30

x

$20

= $600

051223100010 Ceiling Support Column

$200

x

4

= $800

12

x

$60

= $7200

085100000000 Custom Glass Window

$15

x

9

x

$40

= $360

for cabinets

for countertop = $1500

709

396 sq. ft = $5940

LIVE/WORK SPECIFICATIONS SUMMARY Total Material and Labor Costs: 83,083 + 31, 778.40 = $114,861.40

Live/Work Cost Per Square Foot (1964 sq. feet): $58

Specifications: LIVE/WORK SPECIFICATIONS

SP1.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

SP2.00

Specifications: RETROFIT SPECIFICATIONS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

COMMUNITY CENTER SPECIFICATIONS SUMMARY Total Material and Labor Costs: $69,486.99 + $24,408= $93,894.99 Cost Per Square Foot (4524 sq. feet): $20.75

Specifications: RETROFIT SPECIFICATIONS

SP2.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

CHURCH CSI

Material

Price

Area/Quantity Material

Man Hrs

$/hr

Labor

072113100010 R-30 Batt Insulation

$1/sf

x

2200

= $2200

3

x

$60

= $180

0925001

Gyspum

$10

x

169

= $1690

60

x

$60

= $3600

061110022200 2” x 4” x 6 Wood Studs

$3

x

9

= $27

10 x

$60

= $600

061110022200 2” x 4” x 8 Wood Studs

$3

x

124

= $372

40

x

$60

= $2400

061110022200 2” x 4” x 12 Wood Studs

$17

x

29

= $493

10

x

$60

= $600

040120300010 CMU blocks 8x16

$12

x

220

= $2640

20

x

$60

= $1200

096400000000 Wood Flooring

$ 10

x

2914

= $29140

40

x

$60

= $2400

099103200300 Interior Paint

$35

x

30

= $1050

60

x

$60

= $3600

099250001

$76

x

6

= $456

20

x

$20

= $400

096429108015 Transition Molding

$10

x

50

= $500

20

x

$15

= $300

113113433300 Garbage Disposal

$160

x

1

= $160

0.25 x

$20

= $5

224116303300 Stainless Steel 43” Kitchen Sink

$ 300

x

1

= $300

3

x

$20

= $60

224139101300 Kitchen Faucet with Pull Out Spray

$70

x

1

= $70

0.8 x

$20

= $16

13113239797

$500

x

1

= $500

4

x

$40

= $160

113113130750 Range, Freestanding w/oven 1.6

$500

x

1

= $500

2

x

$40

= $80

113113534150 Range Hood

$140

x

1

= $140

2

x

$40

= $80

113113131250 Microwave Oven

$200

x

1

= $200

2

x

$20

= $40

123223100700

$3000

for cabinets

= $3000

25

x

$60

= $1500

123600000000 Countertops

$1500

for countertop = $1500

8.25 x

$60

= $495

220505101301 Lavatory Sink

$120

x

4

= $480

4

x

$40

= $160

224139102120 Lavatory Faucet with Pop up Drain

$35

x

4

= $140

4.8 x

$40

= $192

1554002

$200

x

3

= $600

12

x

$25

= $300

224213403300 Urinal

$200

x

3

= $600

4

x

$25

= $100

051223102400 Bathroom Stalls

$150

x

3

= $450

3

x

$20

= $60

$1,615.99

x

1

= $1,615.99

3

x

$20

= $60

$150

x

10

= $1500

24 x

$40

= $960

Kilz Primer

Refrigerator

Custom Cabinets

Toilet, Low Flow

235415133526 Gas Furnace 081416090010 Smooth Wood Door

SP2.02

Specifications: RETROFIT SPECIFICATIONS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

CHURCH continued CSI

Material

Price

083200000000 Sliding Glass Doors

Area/Quantity Material

Man Hrs

$/hr

Labor

$300

x

4

= $1200

24

x

$40

= $960

$50/ 8 Linear ft.

x

60

= $3000

40

x

$40

= $1600

$15/sf x

6

= $90

3

x

$60

= $180

260590106200 Light Fixtures

$50

20

= $1000

20

x

$25

= $500

220505000000 Plumbing Piping

$14,000

estimated

= $1400

calculated in estimate

260500000000 Electricity Installation

$5,000

estimated

= $5000

calculated in estimate

097223102100 Wood Veneer Paneling 088100000000

Single Pane Glass for Existing Stained Glass

x

Preliminary Total:

= $62,013.99

= $22,788

STORAGE WALL CSI

Material

Price

Area/Quantity Material

060505106164 Plywood 3/4” Framing

$44

x

22

= $968

051223790050 Beams, W 6 x 9

$305

x

3

= $915

050523310100

$8

x

100

= $800

064439200050 Columns, aluminum 2” x 4” rect. tube

$14

x

11

= $154

097223102750 Acrylic PVC, .028”

$56

x

25

= $1400

095123103700 Perforated Aluminum Sheets

$32

x

18

= $576

085113201000 Aluminum Window, 3’-1” x 3’-2”

$20

x

50

= $1000

Preliminary Total:

= $5813

1/2” diameter 1-1/2” Long Bolts and Hex Nuts, Steel

Man Hrs

$/hr

Labor

60 x $15 = $900

= $900

STAIRCASE CSI

Material

034123500020

Precast Stairs, Concrete Treads, Steel Stringers

055213500010

Railing, Pipe, 3’- 6” High, Shop Fabricated

Price $40

Area/Quantity Material x

34

Preliminary Total:

Man Hrs

$/hr

Labor

= $1360

20

x

$60

= $120

= $300

10

x

$60

= $600

= $1660

= $720 Specifications: RETROFIT SPECIFICATIONS

SP2.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

CUSTOM GARAGE DOOR CSI

Material

081213130025

Price

Area/Quantity Material

Man Hrs

$/hr

Labor

$57

x

24

= $1368

20

x

$20

= $400

062516104700 Plywood Paneling, Birch, 1/2” Thick

$95

x

8

= $760

5

x

$20

= $100

085216150320

Windows, Wood, Double Insulated 36” x 40”

$63.50 x

1

= $63.50

1

x

$20

= $20

050523310100

1/2” diameter 1” long Bolts and Hex Nuts, Steel

$6

2

= $12

Steel frame, Hollow 16 ga up to 5-3/4” deep

x

Preliminary Total:

= $2203.5

= $520

COMMUNITY CENTER SPECIFICATIONS SUMMARY Total Material and Labor Costs: $69,486.99 + $24,408= $93,894.99 Cost Per Square Foot (4524 sq. feet): $20.75

LAWN CSI

Material

Material Cost

Labor

210523506210 Sprinkler System Valves/Components Orbit 5400 Plastic Spring-Loaded Pop-Up Sprinkler Head

8 x $3.28 = $26.24

Orbit 3/4” FPT Auto Inline Valve NFC

1 x $13.13= $13.13

Orbit 12” Standard Valve Box

1 x $21.90 = $21.90

Hunter Industries x Core 8 Station Controller

1 x $98.88

Orbit 3/4” Eco-Lock Tee

1 x $1.79

200 hours for sprinkler, plumbing, concrete casting x $60 =

211113160010 PVC Charlotte Pipe 3/4” x 10 PVC Pipe

( Total Length 120 ft)

12 x 2.18 = $26.16

Mueller Streamline 3/4” PVC 90 degree S x S Elbow

11 x $.47 = $5.17

Mueller Streamline 3/4” PVC S x S Tee

4 x $0.47 = $1.88

Lasco 3/4” 90 degree PVC SCH 40 Side Outlet Elbow

1 x $1.60 = $1.60

$12,000

031113000000 Structual Cast-In-Place Concrete Forming Concrete Pat

(Total ft3: 250 ft3 w$75/cubic yard = $3/cubic feet) 250 x $3= $750

Concrete Grid

( Total ft3 = 62.5 ft3)

62.5 x $3 = $1572

329223000000 Sodding

(Total Sq. Feet 900 )

900 x $.5 = $450

063216100010 Wood Handrails and Railing

(Total Linear ft. 73 ft)

LAWN SPECIFICATIONS SUMMARY

SP3.00

$352.36

Total Material and Labor Costs: $5,524.61 + $13,574.21= $19,098.8

Specifications: GARAGE DOOR AND LAWN SPECIFICATIONS

5 x $60 = $300 $754.21

Lawn Cost Per Square Foot (1630 sq. feet): $11.71


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

LAWN SPECIFICATIONS SUMMARY Total Material and Labor Costs: $5,524.61 + $13,574.21= $19,098.82 Lawn Cost Per Square Foot (1630 sq. feet): $11.71

LIVE/WORK RENOVATION +

CHURCH & Supporting Components +

LAWN

= CUMULATIVE TOTAL: $227,855.21

Specifications: GARAGE DOOR AND LAWN SPECIFICATIONS

SP3.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

Client

Action Housing

grants/foundations contracting

contracting design approval

building

construction permit

real estate

Special Exception Zoning Application for Community Center and Religious Assembly

Design architects & consultants

hired as designers contracting surveying site

site analysis

geotechnical survey schematic design

design development construction drawings bidding for contractor

Construction

hired as general contractor

contractors & laborers

contracting

surveying site

Municipality City of Pittsburgh

initial review

real estate appraisal

public works review

building permits

PROJECT DURATION

IMP1.00

Implementation Documentation: CRITICAL PATH ANALYSIS

Special Exception Zoning Application for Community Center

1

2

land-use review/zoning site inspection

3


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550 CRITICAL PATH

The critical path represents the entire path of development from permitting to final salary negotiations.

client happy

payment

construction drawings

demolition

change order/addenda specifications writing construction administration

review final completion

review construction drawings attain material demolition construction retrofit cleanup

site inspection

4

5

Implementation Documentation: CRITICAL PATH ANALYSIS

IMP1.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK Construction Process Participants These diagrams show the list of people who would be hired during the construction process and when they would participate during the construction phases. A participant flow is understood, and Action Housing is the continuous backbone throughout the entire pre-construction, retrofitting/construction, and postconstruction phases.

Figure 8.2: Lifecycle breakdown by role.

Figure 8.3: Lifecycle breakdown by entity.

IMP2.00

Implementation Documentation: LIFECYCLE ANALYSIS


ACTION UPTOWN: CORNERSTONE OUTLOOK

mo

n

1 2

9

th

ur

s

at - s

10

-

fri

11

12

3

8

ARC48_550

4

7

sun

5 6

6 5

7 4

8 3

9 2

10 1

12

11

breakfast / open

prepare

individual work shift

close / maintenance

sleep

Figure 8.9: Daily use diagram for housekeepers.

Implementation Documentation: LIFECYCLE ANALYSIS

IMP2.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK Community Program Flow Diagrams basement

These diagrams represent the flow of the activities that could occur in the spaces and how the activities would be happening simultaneously in the partitioned spaces. These diagrams also indicate when the Live\Work people would have to be on duty to ensure the smooth flow of operations. Only a small portion of the possible combinations of the overlapping activity is depicted with these diagrams.

main floor 11

12

1 2

10 9

lawn 3

8

4

7

5 6

6 5

7 4

yoga

8 3

9 2

child activity

10 1

12

11

fitness

basement main floor 11

12

1 2

10 9

lawn 3

8

4

7

5

movie night

6

6 5

7 4

yoga

8 3

9 2

10 1

12

child activity

11

fitness

basement main floor 11

12

1 2

10 9

lawn 3

8

4

7

5 6

6 5

7 4

8 3

9 2

10 1

12

11

community event

church service

IMP3.00

Implementation Documentation: BUSINESS MODEL


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

Community Program Flow Diagrams, continued Plans have been drawn to provide a spatial correspondence to the other more conceptual diagrams on the left. The gym and the kitchen are two main spaces of activity on the basement level. The largest flexible space and the two smaller flexible spaces are on the ground floor level. The lawn can also be used for outdoor activities, and a portion of the lawn has been highlighted to show the possibility of a community garden. The enclosed balcony level can be used for meetings and seminars and is the more stationary and less flexible part of the program. It also has the potential to become a computer cluster.

Figure 8.9: Daily use diagram for housekeepers.

Implementation Documentation: BUSINESS MODEL

IMP3.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK ACTIVITIES REVENUE MODEL This is a reference page from an activities guide in a suburban town with a population slightly smaller than Pittsburgh. The hope is that the multiple spaces in the community center can be rented out to instructors who are interesting in engaging the immediate and greater community of Pittsburgh in a variety of activities. These activities could include cardio workouts, dancing, arts and crafts, computer use and program training, martial arts classes, and seminar classes. The projected revenue below is based upon full usage.

Figure 8.10: An example activities page showing the cost of the class and the days \hours of the particular session. $13,152 are generated based upon 10 people per class for just this page.

Basis

Example

Projected Revenue

The rental fee for the spaces

With just three example classes,

$13,152 (for five simultaneous classes

would be

15%

of the cost of the class.

$923.25 are generated.

x 3 (Morning/Afternoon/Evening) =

$39,465 per season x 2 seasons = $78,912 per year

maximum usage

Figure 8.11: Example of an average class’ income.

IMP3.02

Implementation Documentation: BUSINESS MODEL


ACTION UPTOWN: CORNERSTONE OUTLOOK

REVENUE OF INDIVIDUAL ACTIVITIES

Location : BASEMENT $19.00 x 25 people= $475 x 0.15 =

ARC48_550

$71.25

These examples show possibilities of classes within the spaces and the revenue that can be generated

Morning

Afternoon

Evening

per class. These examples only show a single occupant during a particular time period, so it gives an idea of a breakdown per class. However, all five spaces can be used simultaneously at concurrent hours of the day.

Figure 8.12: A class for adults.

Location : LOFT

$267

$89.00 x 20 people = $1780 x 0.15 = Morning

Afternoon

Evening

Figure 8.13: A class for school age children.

Location : MAIN SPACE $130.00 x 30 people = $3900 x 0.15 = Morning

Afternoon

$585 Evening

Figure 8.14: A class for pre-school children.

Location : STORAGE $30.00 x 30 hours/week = $900 x 0.15 = Morning

Afternoon

$135 Evening

Implementation Documentation: BUSINESS MODEL

IMP3.03


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK INITIAL FUNDING Action Housing - General funds:

“To empower people to build more secure and self-sufficient lives through the provision of decent, affordable housing, essential supportive services, asset building programs...” Pennsylvania Department of Community & Economic Development - Community Services Block Grant:

$150,000

“To revitalize low-income communities and empow-

er low-income families and individuals to become fully self-sufficient. “ $50,000

Deadline: June 30, 2012 The Pittsburgh Foundation - Will identify funders for the project:

“To foster sustainable communities, defined as those which seek to seamlessly integrate economic, social equity and environmental goals in order to enhance the quality of life for residents of Allegheny County.”

$50,000

5 Times a Year Roy A. Hunt Foundation - Community Development Initiative: “Neighborhood Revitalization – Developing viable communities and revitalizing distressed neighborhoods through collaborations or partnerships.”

$300,000

$50,000

June & November Figure 8.15: Sources of funding.

IMP4.00

Implementation Documentation: REVENUE ANALYSIS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550

REVENUE ANALYSIS

Expenses Available Funds

The projected revenue over 30 years utilizes the following variables and constants: a $300,000 loan, a mortage over 30 years, a yearly class and activities cost, a large maintentance expense every 10 years, the addition of the storage module after 5 years which would generate increasing income every 2 years, the receptionist whose pay increases every 5 years starting at $24,000, $15,000 yearly for utilities and $5,000 for supplies which becomes $8,000 after the storage module is installed. The class and activities cost can be at most $13,152 yearly, an aggressive and active rate. SCENARIO NUMBER ONE: HIGH MORTGAGE

$600,000.00

$400,000.00

$200,000.00

$0.00

In the event of a high mortgage, up to $570,000, the regular maintenance cost can only be $30,000, the classes and activities have to be the full $13,152 yearly, and the proposal breaks profit midway through year 9.

-$200,000.00

Figure 8.14: A class for pre-school children.

SCENARIO NUMBER TWO: LOW ACTIVITIES COST $400,000.00 $300,000.00 $200,000.00 $100,000.00 $0.00

If the proposal aims to make the class and activity services as low as possible, at $10,916, the mortgage can be at most $400,000, the regular maintenance cost can only be $30,000, and the proposal breaks profit at the start of year 7.

-$100,000.00

Figure 8.14: A class for pre-school children. $700,000.00

SCENARIO NUMBER THREE: MAXED MAINTENANCE

$600,000.00 $500,000.00 $400,000.00 $300,000.00 $200,000.00 $100,000.00 $0.00

If the decennial maintenance cost is at its maximum of $100,000, one of two revenue paths can occur. The first is that the mortgage allowance rises to $486,000 with the class and activities cost at its maximum and the proposal breaking even in fall of the 5th year.

-$100,000.00 -$200,000.00 -$300,000.00

Figure 8.14: A class for pre-school children. $500,000.00 $400,000.00

The second path has the class and activities cost decrease to $11,986, the mortgage allowance lowers to $400,000, and the proposal breaks even halfway through year 3.

$300,000.00 $200,000.00 $100,000.00 $0.00 -$100,000.00 -$200,000.00

Figure 8.14: A class for pre-school children.

Implementation Documentation: REVENUE ANALYSIS

IMP4.01


ARC48_550 ACTION UPTOWN: CORNERSTONE OUTLOOK

LIVE/WORK RENOVATION +

CHURCH & Supporting Components +

LAWN

= CUMULATIVE MATERIAL & LABOR TOTAL: $227,855.21 Additionally, exercise equipment will need to be purchased for the basement and will contribute to a greater final cost. However, the funding of this will have to be acquired, so the cost of exercise equipment will not be an initial cost. It wil be factored in at a later time, but it is shown here as another phase of cost.

ProForm 505 CST Treadmill Model #: PFTL60910

Amount: 3 x 599.99 = 1799.97

EPIC A17U Upright Exercise Bike Model #: EPEX13912

Amount: 2 x 399.99 = 799.98

PowerBlock Sport Bench Model #: IB-SBE-S

Amount::2 x 199.99 = 399.98

Body Solid Rubber Hex 5-50 lb Dumbbell Set Model #: SDRRS550

Amount: 1 x 999.99 = 999.99

Body Solid GDR363 3 Tier Horizontal Dumbbell Rack

Amount: 1 x 149.99 = 149.99

Fitness Gear 2x6 Folding Exercise Mat

Amount: 5 x39.99 = 199.95

Crescendo Fitness Deluxe Sit-up Bench Model #: 44240

Amount: 1 x 57.99 = 57.99

COST OF EXERCISE EQUIPMENT: $4,407.85

NEW TOTAL: $232,263.06

IMP5.00

Implementation Documentation: HARD COSTS


ACTION UPTOWN: CORNERSTONE OUTLOOK

ARC48_550 SOFT COSTS

Live/Work

1964 NASF x 5% GUF = 2062.2 GASF

Community Center

4524 NASF x 5% GUF = 4750.2 GASF

Permit Fees

Architect’s Design Fee is 20% of construction costs = $74,239.17. However, 39.5% is allocated to structural, 24% to mechanical/plumbing (which is already calculated into the CSI), landscape, and other fees. The architect’s fee is then reduced to $53,027.98.

$700 first $50,000, $8 each additional $10,000 of construction cost 2062.2 GASF + 4750.2 GASF= 6812.4 GASF

So then, 6812.4 + 0.5 (x) +700 + (8(x-50000/1000) - 225(x)= is broken down as

Development Fees

10% of total construction

Impact Fees

5% of total construction

Bonding

5% of total construction

Construction Contingency Extraction

10% of total construction

A&E Consult

20% of total construction

These fees are 50% of construction costs.

Total Costs of Project

$227,855.21

Standard Overhead of 10% is used. Contingency of 15% is also used. New Total Cost with Overhead and Contingency

$284,819.02

Permit Fee

$932

Development Fees

$28,481.902

Imact Fees

$14,240.95

Bonding

$14,240.95

Construction Contingency Extraction

$28, 481.02

A & E Consult

$56,963.80 Total Fees

New Total

$143,340.62

$371,195.83

Implementation Documentation: SOFT COSTS

IMP5.01