Straumann 速 Temporary Abutments Your solution for narrow spaces
your solution for More solutions
pp Narrow diameter for narrow interdental spaces pp Crowns and bridges pp Screw- and cement-retained pp Anterior and posterior region
Indication and intended uses
Bone Level Temporary Abutments are intended to be used with Straumann速 Bone Level Implants for temporary restorations of single crowns and bridges in the anterior and posterior region. For intraoral use up to 180 days.
Engaging abutments are used for
Non-engaging abutments are
pp Screw- or cement-retained temporary crowns pp Cement-retained temporary bridges
used for
ContraIndication
Allergies or hypersensitivity to chemical ingredients of the titanium alloy
pp Screw-retained temporary bridges
narrow spaces Ø 3.5 mm
11 mm
Ø 3.2 mm
Product Information
pp The devices are provided non-sterile and are for single use only pp The abutment can be steam sterilised (134 C° / 18 min) pp Material: Titanium alloy (TAN / Ti - 6Al - 7Nb) pp Product sold with screw pp Provisional restorations are to be placed out of occlusion pp Shortable up to 6 mm with usual tools and technique pp Yellow anodization on NC Abutments, no anodization on the RC Abutments pp Consistent Emergence Profile™ pp Reliable CrossFit™ Connection pp Easy lab and chair-side temporization pp Not grindable (no diameter reduction or emergence profile customisation possible)
Ø 3.4 mm
Ø 3.5 mm
11 mm
11 mm
Ø 4.5 mm
Ø 3.2 mm
Frequently Asked Questions Why is there an NC non-engaging temporary abutment but not an NC non-engaging gold abutment?
The stress is lower and there is shorter patient contact Ø 3.4 mmwith a temporary abutment than with the gold abutment. Why is the RC screw channel smaller than that of the RC non-engaging gold abutment?
Ø 4.5 mm
11 mm
The TAN Material of the temporary abutment is stronger than the gold alloy used for the gold abutment and therefore allows a smaller diameter for the temporary abutment.
NC & RC Temporary Abutments* Art. No.
Article
Dimension
024.2371
NC Temporary Abutment, for crown
Ø 3.5 mm L 11.0 mm
024.2375
NC Temporary Abutment, for bridge
Ø 3.5 mm L 11.0 mm
024.4371
RC Temporary Abutment, for crown
Ø 4.5 mm L 11.0 mm
024.4375
RC Temporary Abutment, for bridge
Ø 4.5 mm L 11.0 mm
* Not every products are available in all countries.
International Headquarters Institut Straumann AG Peter Merian-Weg 12 CH-4002 Basel, Switzerland Phone +41 (0)61 965 11 11 Fax +41 (0)61 965 11 01 © Institut Straumann AG, 2009. All rights reserved. Straumann® and/or other trademarks and logos from Straumann® that are mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. All rights reserved.
03/09 152.749/e