PRODUCT DATA SHEET StorMaxx CTec Storage Tanks

Technical Specifications Capacity (gal)

Diameter w/o insulation (in) Height w/o insulation (in) Diameter w/ insulation (in) Height w/ insulation (in) Tilted height (in) 1 x 1 in. Steel bare-tube solar coil (sq. ft.) 1 x 1 in. Steel DHW coil (sq. ft.) 1 X 1 in. Steel bare-tube boiler tie-in/aux. coil (sq ft.) Heating area top/bottom (ft2) Heating area * corrugated tube (ft2) Water content * top/bottom (gal) Water content * corrugated tube (gal) Performance Index ** according to DIN 4708 10 min. peak consumption at temperature of the stand-by part *** 125.6° F (gal) 10 min. peak consumption at storage tank temperature *** 149° F (gal) max. T/max. P **** (° F/psi) max. T/max. P buffer storage tank (° F/psi) Max. Δp storage tank/WT corrugated tube (psi) Number of Heat Exchanger Coils Number of Circulation Ports Circulation (Z), external thread (in) ***** Filling/draining connections (A2-A5), external thread (in) Filling/draining connections (A1 +A6), external thread (in) Electric heating, int. thread (E-HZG) (in) Nominal width of the inspection flange (RFL) Connections for sensors/regulators Thermometer connection * Heat exchanger ** In order to achieve the performance index give4n here the boiler output needs to be higher than the stated continuous output. *** Stand-by part between connections A5 and A6; continous output [l/h] = 10 min. Peak consumption x6 when boiler output > continuous output. **** Heat exchanger (warm water) ***** Circulation is possible via T piece in the cold water inflow

© 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.

StorMaxx CTec-211-3HX 211

31.1 79.5 39 79.5 81.1 26 54 26 25.83 54 3.83 7 2.5 55 85.6 230/232 203/43.5 87 3 6 G¾ G1 G 1¼ Rp 1½ No option Sensor terminal block No option

SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com


PRODUCT DATA SHEET, continued StorMaxx CTec Storage Tanks

• • • •

CFC free soft foam insulation with a thickness of 4 inches and a PVC coating, RAL colors 9006; 9010; 2002; 5015 CFC insulation is removable - tank can fit through 32 inch entry ways Three exchanger coils: two bare steel for the solar loop and/or boiler tie-in, and a 54 ft2 stainless steel domestic hot water exchanger at the top of the tank. Unique installation attached via a large zipper and has an R-value of 16.

SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com © 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.


APPROVAL STAMPS

Architectural Stamps and Remarks

Contractor Stamp and Remarks

Contractor Note - Sign Below

SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.