PRODUCT DATA SHEET StorMaxx Ptec Storage Tanks StorMaxx Ptec 502HX
StorMaxx Ptec 802HX
StorMaxx Ptec 1052HX
StorMaxx Ptec 1302HX
50
80
105
130
Dia. w/o insulation (in)
19.7
19.7
23.6
25.6
Dia. w/ insulation (in)
23.6
23.6
27.6
29.5
Technical Specifications Capacity (gal) *
Insulation (in)*
2
Height w/ insulation (in)
48.5
66.8
65.4
70.2
Tilted height (in)
53.9
70.9
70.9
77.6
6.5/8.6
8.6/12.9
10.8/16.2
12.9/19.4
1/1.3
1.3/2
1.7/2.5
2/3
185/317
264/423
317/528
370/634
0.44/1
.5/1.3
.65/1.74
.8/3.6
Performance index top/bottom† according to DIN 4708
1.23/3.6
1.8/8
2.1/11
2.5/14
Continuous output top/bottom according to DIN 4708 (50°F/180°F/115°F) (gal/hour)
108/188
160/256
190/312
219/370
Heat area top/bottom (ft2) Water content WT top/bottom (gal) Volume flow WT top/bottom (gal/hour) Pressure loss WT top/bottom (psi)
Max. T/max. P TW (°F/psi)
200 / 145
Max. T/max. P HZG (°F/psi)
320/363
‡
Cold-/Hotwater, ext. thread (KW/WW) (in)
G1
Circulation, ext. thread (Z) (in)
G¾
Heat exchangers, all ext. threaded (VL/RL) (in)
G¾
Electric heating, int. thread (E-HZG) (in)
G 1½
Nominal width of the inspection flange (RFL)
DN 110
Connections for sensors/regulators (F1, F2)
Sensor sleeve, inside diameter 9 mm
Thermometer connection
M8 thermometer optional
Insulation is not detachable. In order to achieve the performance NL given Here, the boiler output needs to be higher than the stated continuous output. ‡ The working medium of the heat exchanger is water in liquid state only. *
†
• • • • • • • • •
Upright storage tank made of steel S235JRG2 with 2 large surface bare-tube heat exchangers Enameling in accordance with DIN 4753 Part 3 on the inside, primer applied to the outside Magnesium protection anode of 1¼’’ provided for completion of the cathodic corrosion protection in accordance with DIN 4753 Part 6 Sensor tube included As standard fitted with a 1½’’ sleeve for re-fitting of an electric heating element Inspection opening 180 x 110 x LK 150 All external threads are flat sealing CFC-free hard PU-foam insulation with a thickness of 50 mm and a casing of foil-clad, colored synthetic material in accordance with DIN 4753 Part 8, RAL colours 9006; 9010; 2002; 5015 Compressive strength 10 bar
© 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.
SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com
PRODUCT DATA SHEET, continued StorMaxx Ptec Storage Tanks
7
1
11 5 8 6 5 10 3 8
9
4 2
1. Hot Water Outlet 2. Cold Water Inlet 3. Solar Supply 4. Solar Return 5. Auxiliary Coil Port 6. Recirculation Port 7. Magnesium Anode 8. Temp Sensor Well 9. Cleaning Flange 10. Electric Heating Element* 11. Thermometer* *Optional components
SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com Š 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.
APPROVAL STAMPS
Architectural Stamps and Remarks
Contractor Stamp and Remarks
Contractor Note - Sign Below
SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com