PRODUCT DATA SHEET TitanPowerPlus SU-2.4 Flat Plate Collector
Technical Specifications Dimensions (in)
96.18 x 38.78 x 3.03 (244,3 x 98.5 x 7.7 cm)
Gross Collector Area (ft2)
25.94 (2.41 m2)
Net Aperture Area (ft2)
24.43 (2.27 m2)
Ratio Net/Gross Area
0.94
Dry Weight (lbs.)
90.39 (41 kg)
Fluid Capacity (gal.)
0.29 (1.1 L)
Minimum Flow Rate (gpm)
0.173 (40 L/hr)
Nominal Flow Rate (gpm)
0.587 (133 L/hr)
Maximum Flow Rate (gpm)
1.05 (240 L/hr)
1
Recommended Flow Rate (gpm)
0.176 - 0.617 (40 - 140 L/hr)
2
Max Number of Collectors in Series
10
Tilt Angle (deg)
35 - 90
Maximum Operating Pressure (psi)
87 (6 bars)
Recommended Operating Pressure (psi)
36.3 - 43.5 (2.5 - 3 bars)
7
Stagnation Temperature
383 °F (195 °C)
8
3 4 5 6
Sealing Casing Lateral thermal insulation Glazing Double-sided adhesive tape Absorber material (copper) Thermal insulation Rear panel
Materials Stainless Steel, grade AISI: 304; 0.7 mm gauge 3.2 mm toughened glass
Mounting Options construction for sloping roof integration into sloping roof on flat roof with stand facade
12-Year Warranty (when installed by a certified installer) SRCC Certified Solar Keymark Certified
© 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.
SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com
PRODUCT DATA SHEET TitanPowerPlus SU-2.4 Flat Plate Collector
RELATIVE EFFICIENCY (η)
PEAK POWER PER COLLECTOR UNIT (Wpeak) Peak Power (Wpeak) Thermal Capacity* Flow rate during test Fluid for test
Reference Gross Aperture η0 0.754 0.801 a1 [WK-1m-2] 3.43 3.64 a2 [WK-2m-2] 0.0106 0.0112
1501 W 4.7 kJ/K 160 l/h Water-Glycol 33.3%
Absorber 0.805 3.66 0.0113
*Specific thermal capacity C of the collector without fluid, determined according to 6.1.6.2 of EN12975-2:2006
3.5 3
Pressure Loss (psi)
2.5 2 GS2400 TIN H
1.5
GSE 2400 TIN Q
Linear (GS2400 T
Linear (GSE 2400
1 0.5 0 0.4
INCIDENT ANGLE MODIFIER (IAM) K1, transversal IAM at 50°
0.95
K2, longitudinal IAM at 50° 0.95
0.8
0.9
1.3
1.4
1.8
1.9
2.2
-0.5
2.5
2.2
2.9
3.1
3.4
3.5
3.9
4.0
4.2
4.4
Flow Rate (Gpm)
GS 2400 TIN H GSE 2400 TIN Q
SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com
© 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.
APPROVAL STAMPS
Architectural Stamps and Remarks
Contractor Stamp and Remarks
Contractor Note - Sign Below
SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com