PRODUCT DATA SHEET IntellaMaxx DTC Controllers Technical Specifications

DTC-1

DTC-D

Operating Voltage (V)

3.5 - 24

0 - 24

30

24

Solar panel (or battery) nominal voltage (V)

12 or 24

12

Pump Voltage (V)

12 or 24

12 or 24

Adjustable Differential (F)

N/A

4 - 32

Adjustable Max Temperature Shut Off (F)

N/A

100 - 200

Adjustable Max Temperature Shut Off (C)

N/A

37 - 93

Adjustable Freeze Protection (F)

N/A

1 - 36

Adjustable Freeze Protection (C)

N/A

-17 - 2

2.5 x 3.5 x 1.25

2.5 x 4.75 x 1.25

65 x 88 x 42

65 x 120 x 42

Ambient Operating Temperature (F)

32 - 158

0 - 160

Ambient Operating Temperature (C)

0 - 70

-18 - 70

Max. Operating Voltage (V)

Dimensions (not including mounting ears) (in) Dimensions (not including mounting ears) (mm)

DTC-1 Features: · · · ·

Internal pump control switch: ON / AUTO / OFF Can switch up to 6 Amps (72 Watts) Uses standard 10K thermistor sensors Fixed differential < 1F

DTC-D Features:

· Internal pump control switch: ON / AUTO / OFF · Can switch up to 6 Amps max (72 Watts at 12 Volts) · Uses standard 10K NTC thermistor sensors · Fixed differential < 1F · Digital temperature display accurate to 1°F (2°C) · All settings maintained in permanent flash memory · Internal 4.8V batter (4 AAA NiMH) operates device for up to 3 days without solar power

SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com © 2010 SunMaxx Solar, Inc. Specifications subject to change without notice.


APPROVAL STAMPS

Architectural Stamps and Remarks

Contractor Stamp and Remarks

Contractor Note - Sign Below

SunMaxx Solar, Inc. 56 Broome Corporate Pkwy Conklin, NY 13748 1.877.786.6299 1.800.786.0329 fax www.sunmaxxsolar.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.